Loading...
HomeMy WebLinkAbout4 Development Permit 553 High Ridge Lot 2 FillMUNICIPAL DEVELOPMENT GROUP 203 Holleman Drive East• College Station, Texas 77840 • 409-693-5359 •FAX: 409-693-4243 December 20, 1995 Veronica Morgan, P.E . Asst. City Engineer City of College Station Post Office Box 9960 Engineering, Surveying, Planning and Environmental Consultants College Station, TX 77842-9960 Re : Development Permit for Lot Two, Block One, High Ridge Subdivision, Richard Carter League, College Station, Brazos County, Texas . Dear Veronica: Varsity Ford proposes to fill a section of Lot Two. Portions of this tract lie within the 100 yr. flood plain based on ground location of elevations stated in F.E.M.A .-FIRM Community Panel No. 48041 C0142 C, July 1992. Along with the flood plain location, the proposed limits of the fill are delineated with bearings and distances on the Site Reclamation Plan. Proposed construction parameters are: select fills shall be limited to clays, compacted to 95% Standard, graded so as not to exceed 4: 1 side slopes and seeded in accordance with Street Spec. No. 709 . Toes of slopes shall meet existing natural ground elevations and will not encroach the flood plain or into the tributary formed by the 30 in. RCP under State Highway 6 Frontage Road discharging into Carter's Creek. (The limits were established by offsetting the northeast and southeast property line 15 ft ., the southwest property line 24 ft. and the 100 yr. flood plain and tributary approximately 20 ft.) Before development, the entire tract sheetflows in a northerly direction toward Carter's Creek, away from State Highway 6 Frontage Road. The proposed fill will allow the entire site to continue to discharge into Carter's Creek. The sideslopes surrounding the fill section shall be seeded for erosion control. The potential for erosion along the southeasterly property line was investigated . Seeding this area will keep the velocities less than 4 .5 ft./sec. for up to a l 00 YR rainfall event satisfying Table VII-2 in the City of College Station's Drainage Ordinance . The proposed construction does not significantly alter the drainage characteristics, meets City of College Station's Drainage Ordinance and follows good engineering practice. Sincerely, UB.~} North B. Bardell, Jr . P.E . No. 60873 Enclosure Varsity Ford ~ = LINCOLN MERCURY PAY ... TO THE O RDER OF · > Cash -- 1309 TEXAS AVENUE (409) 779-0664 BRYAN , TEXAS 77803 11 1 0 •• j ~ j 11 1 I: •• j • 0 2 5 7 8 I: THANK YOU Victoria Bank & Trust Bryan . Texas 77802 DATE 0011343 88-257 1131 Figure XU Application Form Development Permit Inside/Outside Established Flood Hazard Areas City of College Station, Texas (re: Ordinance No. 1728) i..o-r 'Z. I 13l-o~ 1, H l6(H 12 l DGfE ~L.Jf30l VIS/ON Site U:gai Description: £Ja+~D CAJ2-TEP. ~E., Aes~T No. 8 Site Address : _______________________________ _ Owner: MntON '( MAJ Ol<S-VA(<.SIT1' Fof<D Architect/ Engineer: M . D. Ge. Address: I~ fex'.AS AVc., f!>f<.'{AN Telephone No.: (4'9q) "770, -o'-k4= Address: ioa t-tol-l.Q\MN e. / v. ~. Telephone No.: (4oq) C,q ~-6'3?9 Contractor: Address: ----------------~~~ -~--------~~ Telephone No.: ________ _ Date Application Filed: ______________ Approved:----------- Appli<?ltion is hereby made for th~ fol~owing speci?c waterway alterations:------------ Attached as part of this application: O Application Fee O Signed Certificate 0 Site and Construction Plans, with supporting documentation: two (2) copies of each O Other:----------------- ACKNOWLEDGEMENTS: I, J. Vi Maj<1r5 67 /?J.; !lip J3, ('is lner, hereby acknowl.;.ige or affirm that: I • I The above Drainage Plan and supporting documents complies wiht the requirements of Ordinance No. 1728, and 6' 4 v Maj,,. i>jfi;i; A Kfi/ Owner r; Date Datt! Contractor Date Page 1of2 Figure XII Continued CERTIFICA TIOSS: A. I, certify that any nonresidential structure on or proposed to be on this site as part of this application meets flood-proofing requirements as set out in Section of Ordinance No . 1728 Architect/Engineer Date B. I, certify that the finished floor level of the lowest t1oor, including any basement, of any residential structure as part of this application is or proposed to be at or above the base tlood elevation as established in the latest Federal Insurance Administration tlood hazard study and maps, as amended. Architect/Engineer Date C. I, Nl2~T/./-13 fb.te.p t:LL J~. P.g certify that the alterations or development covered by this pennit shall not diminish the flood-carrying capacity of the adjoining waterway or crossing this permitted site and that such alterations or development are consist~nt with requirementS concerning encroachments of floodways and of floodway fringes as illu.~tratcd in e latest Federa~ura~ce ;;ud 13 ~ j)~ 2-J I 11''1~ • Architect/Engineer Date > D. I, do certify that any alterations, addressed in Certification "D'1 do not raise the level of 100-year flood as referred to Certification 11 8 11 • Atchi tect/Engineer Date· REVIEWED FOR AP PROV AL: ~~-~ ......... ~~ ......... ~-~ ......... ~-Flood p I a in Administrator Date APPROVAL: Special conditions or comments as part of approval: ---------- Paize 2of2. y..,.~ llUNIQPAL DEYn.OPllENT GROUP P.O. Bax 9249 203 Holleman Drive Ent Colleae Station. Texas n840-9249 (409) 693-5359 •·"· rz..-2J -5 -.... An&MTIOtl .. , _ Y!E ARE SENDING YOU x Atbchf/IJ 0 Under separate cover via ________ the followin1 items: . ! COPl£S 0 Shop drawings 0 Copy of letter DATE 0 Prints 0 Chanie order NO. 0 Plans 0 Samples 0 Specifications o __________________ _ DESCRll"TION THESE ARE TRANSMITTED as checkf/IJ below: ){__For approval / 0 -;r your use 0 As requestf/IJ 0 Approved as submitted 0 Approved as notf/IJ · 0 Returned for corrections O Resubmit __ copies for approval D Submit __ copies for distribution 0 Retum __ corrected prints O For review and comment 0 -------------------- 0 FOR BIDS DUE ________ 19 ___ 0 PRINTS RETURNED AFTER LOAN TO US REMARKS------------------------------------------- COPY TO--------------------------------- ,,. [$ __ ..... ...._......,..., .... _