HomeMy WebLinkAbout38 DP 00-0500055 Alexandria Phase 3B' .
Date: December 18, 2000
To: Amanda Hudec, Accountin\\ ..
From: Bob Mosley, City Engineer'r
Subject: Completed Infrastructure from Private Development
By the attached letter of completion for the Alexandria Subdivisi o n Phase 3b
development, we have accepted the following improvements to th e City of College
Station infrastructure.
Streets:
27 foot wide pav em ent
(Mullins Court)
Storm Sewer:
21 inch diameter RCP
24 inch diamet er RCP
Sanitary Sewer:
6 inch PVC sanitary sewer main
SDR 26 (ASTM D-3034)
4 foot diameter m anl1ol es
\Vater:
6 inch PVC main
CL 200 (A WW A C-900)
Fire Hydrant, Type I
494 linear feet
252 linear feet
30 lin ea r feet
l ea ch
492 linear feet
Based upon our previous n1 c...:~i :~g , D cv elopn1ent S 2r\·ic ~.; ~ .. · b c ~~:r1 r:·J ,·i l~:i1~
engineering estimates with the p ri,·~L: d ev elopment pl an s . Tli >" :·'. ~::J "" us to id c ntir;·
th e cost of the infrastructure in t :.-:: fut ure. We do not h ave tk : _ ··.::.· .. _'::·ing cs t irn Jl cs fo :·
this project. This memo provides a record of the infrastructure acceptance, however, the
engineering cost estimates for this infrastructure will be required from Development
Services.
c: Natalie Ruiz, Development Coordinator
Vern Wright, Engineering Technician
Missy Green, Staff Assistant
LETTER OF COMPLETION
CITY ENGINEER
CITY OF COLLEGE STATION
COLLEGE STATION, TEXAS
Dear Sir:
RE:
DATE: I LI \I\ d--"" 0
COMPLETION oFA /e)t5b,v~~
?~A5e... 3 B
The purpose of our letter is to request that the following listed improvements be approved
and accepted as being constructed under city inspection and completed according to plans
and specifications as approved and required by the City of College Station, Texas . This
approval and acceptance by the City is requested in order that we may finalize any sub-
contracts and to affirm their warranty on the work. This approval and acceptance by the
City of the improvements listed below does hereby void the letter of guarantee for the
listed improvements on the above reference project.
The one year warranty is herby affirmed and agreed to by -'=E'-"l=-f.:....-..:-.9.:.:..::.0,_{.'-'b_..\.!..l\..!.t'i_q-4----and
by their sub-contractors as indicated by signatures below. 1
WORK COMPLETED \t,
fd-Ree-f~
Owner: P)JJA£f) £l::@L-1J.1.f
Address: 38:&7 d!f!! ,4~.~ /i?.
{1Ltf1~ :'5rAvt,}1 fl-. /764.,;{
Signat:£j_~ctffa,J£ f
I~
Address: f 0 -g o Y ~ 3 3 g
f?JL<-i /lr1'J I <V)(A-_s 718 o l
Signature :'/~ ~ ~
J~112;;J
ACCEPTANCE & APPROVAL
LETTER OF COMPLETION
CITY ENGINEER
CITY OF COLLEGE STATION
COLLEGE STATION, TEXAS
'i
Dear Sir:
RE:
DATE, IL/ 11\d-""o
COMPLETION OF A /e )l S hJV'dqZ..~
?~Ase.. 3 B
The purpose of our letter is to request that the following listed improve m e nts b e approved
and accepted as being constructed under city inspection and completed according to plans
and specifications as approved and required by the City of College Station, Texa s . This
approval and acce ptance by the City is r eq u ested in order that we may fin a lize any sub-
contracts and to affirm the ir warranty on the work. This approval and acceptance by the
City of the improvements liste d below do es hereby void the l etter of guarantee for the
listed improvements on the above reference project.
The one year warranty is herby affirmed and agreed to by _E_l_\=_-_9._.o_.e.,~b~\~\~{'i-~-+----and
by their s ub-contractors as indicated by signatures b elow.
WORK COMPLETED \i:
>f:Kee+~ ,
LAI A-k f2
Owner: P ')J..<.!Afm nt>C111..-1JJ7
Address: 38:&7 J/;fJI h¢.~Mf fV.
{1Ll&f£ Sun~,)/ J]..· 11~4:{
Signa t:f~cdf~ f
ACCEPTANCE & APPROVAL
Id_
/1 I ;c / __,.--/ ~-k wu~k
Contractor: l. e .IV 1 j 4 Q./,:YA 5 I
Address: f. ()_go Y ~3 3 fl
(J'lV-i ,o/7J T Q/\c~-_s 718 ° l
Signature
1 I~ ~ ~
Item
No.
1
2
3
4
5
6
7
8
9
IO
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
ALEXAND RIA SUBDIVISION, P HASE 3B
ENGINEER'S ESTIMATE
A t 2 2000 ugus '
Description Unit Quantity Estimated
Unit Price
Paving Construction
Mobilization Lump Sum I 1,000.00
Roadway Excavation C.Y. 339 2 .00
1.5" HMAC Surface Course S.Y. 1,588 5.00
6" Lime Stabilized Subgrade S.Y. 1,937 2 .75
Extra Lime Ton 10 96.00
6" Crushed Limestone Base S.Y. 1,588 5.75
Type 3 Curb and Gutter L.F . 1,014 7 .50
Paving Subtotal
Drainage System Construction
21" Reinf Concrete Pipe, Str. Backfill L.F. 252 41.00
24" Reinf Concrete Pipe, Str . Backfill L.F. 30 46.00
5' Curb inlet EACH 3 1,250 .00
Inlet Protection EACH 3 50 .00
Silt Fence L.F. 735 2.00
Construction Exit for Silt Control S.Y . 70 12.00
Fibermulch Seeding S.Y. 2,500 0.50
Drainage System Subtotal
Water System Constructio n
6" PVC Water Line, Str. Backfill L.F . 80 19.00
6" PVC Water Line, Non-Str. Backfill L.F . 412 11.00
Fire Hydrant Assembly, Type II EACH 1 1,900.00
Remove Blow Off and Connect to Existing I EACH 1 150.00
2" Blow-Off Assembly EACH l 440.00
1.5" Type K Copper Water Ser. ( 46 ft. avg. EACH 6 820.00
Trench Safety (water line) L.F . 492 1.00
Water System Subtotal
Sewer System Construction
6" PVC, D-3034, Non-Str. Backfill L.F . 408 16.00
Standard Manhole, 8-10 ft. deep EACH I 1,250.00
4" Sewer Service ,~ 10 ft. (4 ft. avg. length) EACH 4 450.00
4" Sewer Service > 10 ft. (64 ft. avg . length EACH 6 1,100 .00
Trench Safety (sewer line) L.F . 408 1.00
Sewer System Subtotal
Total Constru ction Cost
Page I of I
Total
1,000.00
678 .00
7,940 .00
5,326.75
960.00
9,131.00
7,605 .00
32 ,640 .75
10,332.00
1,380.00
3,750.00
150 .00
1,470.00
840.00
1,250.00
19,172.00
1,520 .00
4,532.00
1,900.00
150.00
440 .00
4,920.00
492.00
13,954 .00
6,528.00
1,250.00
1,800.00
6,600.00
408.00
16,586.00
$82,352.75
Item
No .
J
2
3
4
5
6
7
8
9
JO
I 1
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
ALEXANDRIA SUBDIVISION, PHASE 3B
ENGINEER'S ESTIMATE
A t 2 2000 ugus '
Description Unit Quantity Estimated
Unit Price
Paving Construction
Mobilization Lump Sum J J,000.00
Roadway Excavation C.Y . 339 2.00
1.5" HMAC Surface Course S.Y . 1,588 5.00
6" Lime Stabilized Subgr ade S.Y. 1,937 2.75
Extra Lime Ton 10 96 .00
6" Crushed Limeston e Ba se S.Y. 1,588 5 .75
Type 3 Curb and Gutter L.F . 1,014 7 .50
Paving Subtotal
Drainage System Construction
21" Rein f. Concrete Pipe, Str. Backfill L.F. 252 41.00
24" Reinf. Concrete Pipe, Str . Backfill L.F. 30 46.00
5' Curb inlet EACH 3 1,250 .00
Inlet Protection EACH 3 50.00
Silt Fence L.F. 735 2.00
Construction Exit for Silt Control S.Y . 70 12.00
Fibermulch Seeding S.Y. 2,500 0 .50
Drainage System Subtotal
Water System Construction
6" PVC Water Line, Str . Backfill L.F. 80 J9.00
6" PVC Water Line, Non-Str. Backfill L.F. 412 11.00
Fire Hydrant Assembly, Type II EACH 1 1,900 .00
Remove Blow Off and Connect to Existing ( EACH 1 150.00
2" Blow-Off Assembly EACH 1 440.00
1.5" Type K Copper Water Ser. ( 46 ft. avg . EACH 6 820 .00
Trench Safety (water line) L.F. 492 LOO
Water System Subtotal
Sewer System Construction
6" PVC, D-3034, Non-Str. Backfill L.F. 408 16.00
Standard Manhole, 8-10 ft . deep EACH l 1,250 .00
4" Sewer Service,:::: JO ft . (4 ft. avg. length) EACH 4 450.00
4" Sewer Service > JO ft. (64 ft . avg . length EACH 6 1,100.00
Trench Safety (sewer line) L.F . 408 1.00
Sewer System Subtotal
Total Construction Cost
Page 1 of I
Total
1,000.00
678 .00
7,940.00
5,326.75
960 .00
9 , 131.00
7,605 .00
32 ,640.75
10 ,332.00
1,380 .00
3 ,750 .00
150 .00
1,470.00
840 .00
1,250 .00
19 , 172.00
1,520 .00
4 ,532.00
1,900.00
150.00
440.00
4 ,920.00
492 .00
13,954 .00
6,528.00
1,250.00
1,800 .00
6,600.00
408 .00
16 ,586 .00
$82,352.75
t!JO -oo 5 oo
r/~cn,~
SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION ~
Application is hereby made for the following development specific site/waterway alterations:
Sul:division construction in the drainage basin of the South Fork of Lick Creek.
ACKNOWLEDGMENTS:
I, Michael McClure, P.E. , design eng inccr!HNKN, hereby ackno wl ed ge or affinn tha t:
The information and co nc lu sions contain ed in the above plans and support ing docum ents comp ly with th e current requiremen ts of
the City of Coll ege Stati o n, Texas City Code, Ch a pte r 13 and its ass oc iated Draina ge Policy and Design Standards .
As a condition of approval o f thi s penni t app li cation, I agree to con stru ct th e improvemen ts proposed in this app li catio n accordin g to
these docum e nts and th e equ iremen ts of Chapter I J of t11e Co ll ege St a tion City Code .
I~
sign Engineer Contractor
CERTIFICATIONS: (for proposed alterations wiiliin designated flood hazard areas .)
A. I, , certify iliat any nonresidential structure on or proposed to be on this site as part
of this application is des ignated to prevent damage to ilie structure or its contents as a result of flooding from the I 00 year storm .
Engineer Date
B. I, certify iliat ilie finished floor elevation of ilie lowest floor, including any
basement, of any residential structure, proposed as part of this application is at or above ilie base flood elevation established in ilie
latest Federal Insurance Administration Flood Hazard Study and maps, as amended.
Engineer Date
_,, ..... ,,,,.
C. I, Michael R. McClure, P. E. , certify iliat th e alterati ons or development covered by this permit..$@µ[ ootF r: '''
diminish ilie flood-carrying capacity of ilie waterway adjoining or crossing this permitted site and that such altera~~µ·•"A_"'···~'i'O'\
development are consistent wiili requirements of ilie City of Colle ge Station City Code, Chapter 13 concerning ef"Gfoaehrn~n~--:Of \ *Ip,
flood d ff1 fri I! * : 1""\ •• * ways an o y nges. ~······················"··········· ~ MI CH AEL R. McC LU RE ~ a /z I oo \~·~~ ..... ·327·~:0·· .... .::$~
D t I ' 0 ·.'9~ <(,,<:) •• 41 "" a e ft~·· •. gfSTE~\.·•0" ~ .,$'
'' 8s ·····;a.•• t4.: "' . . . \\ 10NAL C:...'..;,..;' D. I, do certify that t11e propo~ alterauons do not raise ilie leve l of t11e loo..x_i!,a!;,'lll-..,..
flood above elevation established in ilie la tes t Federal Insurance Administration Flood Hazard Study.
Engineer Date
Conditions or comments as part of approval :-----------------------------
In accordance wiili Chapt er 13 of ilie Code of Ordinances of ilie City of College Station, measures shall be taken to insure iliat debris
from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities.
All development shall be in accordance wiili ilie plans and specifications submitted to and approved by ilie City En gineer for the
above named project. All of the applicable codes and ordinances of the City of College Station shall apply .
FTNAL PLAT APPLICATION
FNLPAPP.DOC 4/141'J9
3 of3
FINAL PLAT APPLICATI ON
FOR OFFICE USE O NJ.,Y
P&Z CASE NO.: 0-lµ/
DA TE SUill\ilTTED: -
(check one) Minor __ Amending ;g__ Final __ VaCB.ting __ Rcplat
The following items must be submitted by an established filing deadline date for P & Z Commission consideration .
l\.1INIMUM SUB MITT AL REQUIREMENTS :
XX Fil ing Fee of $200.00.
XX Development P e rmit Applicati o n Fee of S 100 .00 (if applicable).
XX Infrastructu re Inspection Fee of $300.00 (applicable if any public infrastructure is being constructed .).
_xx_ Application completed in full.
XX Thirteen (13 ) folded copies of plat. (A s igned mylar original mu s t be submitted after staff review.)
__ One (1) copy of the approved Preliminary Pl at and/or one (1) Master Plan (if applicable).
_xx_ Paid ta.x certificates from City of College Station, Brazos County and College Station LS.D.
_xx_ A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
XX Two (2)cop ics of public infrastructure plans associated with this plat (if applicable).
APPLICATION DATA
NAME OF SUBDIVISION ALEXANDRIA PHASE 3-B
-----------------------------~
SPECIFIED LOCATION OF PROPOSED SUBDMSION along the north end extension of Alexandria
Avenue and northwest o f Phase-3-A ,
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name Edward Froehling
Street Address 3887 High Lonesome City College Station
State TX ----Zip Code 77845 E-Mail Address
------------~
Phone Number 776-8266 Fax Number 774-0565
----------~
PROPERTY OWNER'S INFORMATION:
Name Edward Froehling
Street Address same as above
----------------~
City --------------
State E -Mai l Address ----Zip Code _____ _
------------~
Phone Number Fax Number
----------~ -------------------
ARCHITECT OR ENGINEER'S INFORMATION:
Name Michael R . McClure, P .E ., R .P .L .S ., McCLURE ENGINEERING , INC .
Street Address 1008 Wcx:xJ.cr eek Drive , Ste . 103
State TX Zip Code 77845
City Col lege Station ,
E-Mail Address mcclure@tca .net
Phone Numbe r 693-5893 Fax Number 693-2554
----------~
F1NALPLAT AJ'PUCATION
FNLPAI'P.DOC Jnj/99
l o f)
..
. TOTAL ACRES OF SUBDfVISION 4. 220 Ac. R-0-W ACREAGE 0. 649 Ac J'OTAL # OF LOTS 18 Lots .r'
NUMBER OF LOTS BY ZONING DISTRICT R-1 I 18 --__ ! __ I ----
AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT:
R-1 / 0.198 Ac. I I ! __
FLOODPLAIN ACREAGE none
PARKLAND DEDICATION ACREAGE OR FEE AMOUNT ----------
A STATEMENT ADDRESSING ANY DIFFERENCES BETWEEN THE FINAL PLAT AND APPROVED MASTER
DEVELOPMENT PLAN AND/OR PRELL\1INARY PLAT (IF APPLICABLE):
REQUESTED VARIANCES TO SUBDIVISION REGULATIONS & REASON FOR SAME _______ _
REQUESTED OVERSIZE PARTICIPATION _____________________ _
TOTAL LINEAR FOOTAGE OF PROPOSED:
453 L.F. STREETS
0 SIDEWALKS
406 L.F. SANITARY SEWER LINES
492 L.F. WATERLINES
0 CHANNELS
279 L.F. STORM SEWERS
BIKE LANES I PATHS -----
NOTE: DIGITAL COPY OF PLAT (IF APPLICABLE ) MUST BE SUBMITTED PRIOR TO FILING.
The applicant has prepared this application and certifies that the facts s.tated herein and exhibits attached
hereto are true, correct and complete. The undersigned hereby requests approval by th e City of College Station
of the above identified final plat.
FINAL PLAT APPLICATION
FNLP APP.DOC 3f25199
Date
2 of)
DEVELOPMENTSERVICES ~ tJ,,tP
TRANSMITTAL LETTER <1~0...:
UIA ~~~~·%-e.-~ L;c;~ O
Name/Firm : ~l:e ~n:I PkA,.te,,·4,. ~~d'~ l,,t:. •
Address : 511(/4,v~ ~ /J,. E .. Ste.. Ut
Col me ~u,~" < rx
Date : '? · J vly 'Z.coo
' Phone : 't:.6~ -Z6 ~~
Fax : ~.(6-tJZZ..~
We are transmitting th e following fo r Development Services to rev iew and comment : (Check all that app ly.):
D Master Developm ent Plan
D Preliminary Plat
D Final Plat
0 FEMA CLOMAIC LOMR/LOMNLOMR
0 Site Plan
D Gradin g Pl an
0 Landscape Pl an
D Irri g ation Pl an
D Buildin g Construct ion Do cum ents
wl 0 Redlines
w/ D Redline s
w/ D Redlines
w/ 0 Redlines
w/ D Redline s
w / D Redlin es
w/ D Redlines
w/ D Redlin es
w/ D Redlines
·~FRASTRUCTURE AND ENGINEERING DOCUMENTS
.11 infrastructure documents must be submitted as a complete set.
The following are includ ed in the complete set :
D Waterline Construction Document s w/ D Redlines
0 Sewerline Construction Documents w/D Redlines
0 Drainage Construction Docum ents w/ 0 Redlines
0 Street Construction Document s w/ D Redlines
0 Easement application with metes & bounds decsription
D Drainage Letter or Rep ort w/ D Redlines
D Fire Flow Analysis w/ D Redl ines
Special fnstructions:
0 Development Permit App .
D Conditional Use Permit
D Rezoning Application
0 Varian ce Requ est
D Othe r -Please specify
1-w,.k.-d d~.15
D TxDOT Driveway Permit
D TxDOT Utility Permit
0 Other -Please specify
1Jae.ck4W/b51 t:'I-<-~,~ >c.-tu,.;t/ed ;,.., reJf+J,,J.L -b ~e..f5 re-:Jl?!d~j !Je..
TRANSMITI AL LETTER
TRANS MIT.DOC 03123/99
l of l