Loading...
HomeMy WebLinkAbout69 Development Permit 636 Sonic Harvey RoadCO-bLEGE STATIO-N --- P. 0. Box 9960 1101 Texas Avenue Tet. 409 764 3500 WOLF PEN CREEK DESIGN REVIEW BOARD College Station , TX 77842 March 18, 1999 TO: FROM: SUBJECT: Mitch Gregory, 101 Park Avenue, Oklahoma City, Oklahoma 73102-7200 Ray Corkran, 829 S. Sam Houston Avenue ., Huntsville, Texas 77340 Design Review Board: Kay Henryson, DRB Member Chara Ragland, DRB Member George McLean, DRB Member Steve Parker, P&Z Commissioner Winnie Garner, P&Z Commissioner Other Attending: Natalie Ruiz, Development COO ma r Bridgette George, Assistant Developmen Nanette Manhart, Mapping Specialist Jane Kee, City Planner .. inator Sonic Restaurant Signage -Proposed freestanding sign to be located at the new Sonic restaurant currently under construction along Harvey Road . (99-430) Mitch Gregory began the meeting by stating that he was willing to work with the Board's recommendation but would like to do everything to protect their trademark sign. Natalie Ruiz reviewed what ·had been approved previously by the DRB and Planning & Zoning Commission. She stated that the elevations of the building depicted the stucco building, with a green stripe around the building that ties in with the green awning . She informed the Board that she spoke with Mr. Corkran after the meeting about putting a neon light in the track of the 6" channel around the building. After meeting with him she polled several of the members about the neon. Mr. Corkran stated that a green light in that channel would look better than any other color. Some discussion took place reg a rding the sign ordin ance in the Wolf Pen Creek district. Natalie Ruiz sta ted th at OfficeM ax originally proposed a red si g n with brig ht yellow background which was denied . Th ey changed it to red letters with a white background, which was approved . The color of yellow for a sig n was discussed. George McLean stated that Kon a's sign was approved because the yellow in their sign is so subtle. Mr. Gregory stated that he understands changing the color of the building to compliment other businesses in the district, but reiterated that he would like to keep their trademark sign. Chara Ragland stated that she thought the yellow clashed with the proposed building colors. She· stated that the yellow in their trademark sign is too bright. She wouldn't be opposed to having the sign outlined in yellow, but not with a background of yellow. Home of Texas A&M University Steve Parker stated that the City has already set a precedent for denying yellow signs in the district and should hold to that. Kay Henryson stated that the proposed trademark sign does not coordinate with the building. She stated that she would not be opposed with a white background with yellow trim. She even mentioned incorporating the green color from the building. Mitch ·Gregory stated that he would design several signs and bring them back to the Board for further review. Mr. Gregory asked if he muted the yellow on the trademark sign, would the Board approve it. The Board stated that they are really trying to stay away from yellow backgrounds and that if he just changed that on the sign, the sign would still not coordinate with the building. Mr. Gregory mentioned that the steel pole for the sign will be painted to match the building. Some discussion took place regarding the wall poster frames and buttons that will be located on the building. The color is normally red. The Board would like it to coordinate with the rest of the building and stated that whatever is proposed, it will have to have ORB approval. Mr. Gregory asked about the cones. The Board stated that they were previously denied by the Planning & Zoning Commission and that issue will not be revisited. Mr. Gregory agreed to design several signs and bring them back for further review. Ms. Henryson asked Mr. Gregory to consider two things when designing the signs. She asked that he not include the bright yellow and to make sure that it coordinates with the building. She also asked for him to provide a site elevation with the signs depicted on the drawings so that the Board could actually see what they are proposing. She also reminded him that his signs will have to meet the sign ordinance for that district, including height restrictions depending on its location. WPC Design Review Board Pagc2of2 DEVELOPMENT PERMIT PERMIT NO 636 Sonic Harvey Road FOR AREAS INSIDE THE SPECIAL FLOOD HAZARD AREA RE: CHAPTER 13 OF THE COLLEGE STATION CITY CODE SITE LEGAL DESCRIPTION: Lot 2 West Wolf Pen Creek OWNER: Sonic Management 829 South Sam Houston Huntsville, TX 77340 (409) 291-0338 SITE ADDRESS: HARVEY ROAD DRAINAGE BASIN: WOLF PEN CREEK TYPE OF DEVELOPMENT: This permit is valid for site work as shown on the approved plans dated 3/26/99 excluding the area within TxDOT right-of-way. Prior to any development activity on the site, the Wolf Pen Creek Dedication Area, as shown on the approved preliminary plat, will be field surveyed. A construction barrier and silt fence will be erected allowing this dedication line to prevent any activity within the dedications area. The Contractor shall take all necessacy precautions to prevent silt and debris from leaving the immediate construction site in accordance with the approved erosion control plan as well as the City of College Station Drainage Policy and Design Criteria. The Owner and/or Contractor shall assure that all disturbed areas are sodden and establishment of vegetation occurs prior to removal of any silt fencing or hay bales used for temporary erosion control. The Owner and/or Contractor shall also insure that any disturbed vegetation be returned to its original condition, placement and state. The Owner and/or Contractor shall be responsible for any damage to adjacent properties, city streets or infrastructure due to heavy machinery and/or equipment as well as erosion, siltation sedimentation resulting from the permitted work. Any trees required to be protected by ordinance or as part of the landscape plan must be completely fenced before any operations of this permit can begin. This permit, being temporary, is valid only within sixty (60) days of the date shown below, and is not intended to allow the complete development of the site as proposed. Any work performed after the expiration of this permit is not covered, and is considered unauthorized. In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. I hereby grant this permit for development of an area inside the special flood hazard area. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer in the development permit application for the above named project and all of the codes and ordinances of the City of College Station that apply. Date Contractor Date DEVELOPMENT PERMIT PERMIT NO 636 Sonic Harvey Road FOR AREAS INSIDE THE SPECIAL FLOOD HAZARD AREA RE: CHAPTER 13 OF THE COLLEGE STATION CITY CODE SITE LEGAL DESCRIPTION: Lot 2 West Wolf Pen Creek OWNER: Sonic Management 829 South Sam Houston Huntsville, TX 77340 (409) 291-0338 SITE ADDRESS: HARVEY ROAD DRAINAGE BASIN: WOLF PEN CREEK TYPE OF DEVELOPMENT: This permit is valid for placement of fill on the proposed lots 2 of the preliminary plat of West Wolf Pen Creek as shown on the approved plans dated 1/7/99. Prior to any development activity on the site, the Wolf Pen Creek Dedication Area, as shown on the approved preliminary plat, will be field surveyed. A construction barrier and silt fence will be erected allowing this dedication line to prevent any activity within the dedications area. It is also valid for site work related to a SLAB ONLY permit. No other sitework is allowed with this permit. The Contractor shall take all necessary precautions to prevent silt and debris from leaving the immediate construction site in accordance with the approved erosion control plan as well as the City of College Station Drainage Policy and Design Criteria. The Owner and/or Contractor shall assure that all disturbed areas are sodden and establishment of vegetation occurs prior to removal of any silt fencing or hay bales used for temporary erosion control. The Owner and/or Contractor shall also insure that any disturbed vegetation be returned to its original condition, placement and state. The Owner and/or Contractor shall be responsible for any damage to adjacent properties, city streets or infrastructure due to heavy machinery and/or equipment as well as erosion, siltation sedimentation resulting from the permitted work . Any trees required to be protected by ordinance or as part of the landscape plan must be completely fenced before any operations of this permit can begin. This permit, being temporary, is valid only within sixty (60) days of the date shown below , and is not intended to allow the complete development of the site as proposed . Any work performed after the expiration of this permit is not covered, and is considered unauthorized. Jn accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. I hereby grant this permit for development of an area inside the special flood hazard area. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer in the development permit application for the above named project and all of the codes and ordinances of the City of College Station that apply. Date •t '°' ~\ \ qq l \'. Date Contractor Date - - DRAINAGE REPORT FOR SONIC DRIVE-IN WEST WOLF PEN CREEK BLOCK ONE, LOT TWO 0.828 ACRE TRACT COLLEGE STATION, BRAZOS COUNTY, TEXAS SEMPTEMBER, 1998 REVISED: OCTOBER 2, 1998 TABLE OF CONTENTS DRAINAGE REPORT PROJECT SUMMARY ................................................................................................ 3 DRAINAGE AREA DESCRIPTIONS .......................................................................... 3 DRAINAGE CALCULATIONS ................................................................................... 4 RESULTS .................................................................................................................... _.5 SECTION #1 -MAPPING SECTION #2 -DRAINAGE AREA: PRE-DEVELOPMENT SECTION #3 -DRAINAGE AREA : POST-DEVELOPMENT SECTION #4 -HYDROGRAPHS SECTION #5 -PROPOSED STORM SEWER SECTION #6 -PROPOSED GRADING & FILL SECTION #7 -DRAINAGE DETAILS West Wolf P en Creek Soni c Drive-In Drainage Report Municipal De velopment Group PROJECT SUMMARY This report outlines the drainage plan for the West Wolf Pen Creek, Lot 2 , 0 .828-acre tract. The subject property site is situated on the southeast side of Harvey Road (State Hwy No 30) approximately 1,500 linear feet northeast of the Texas Avenue and Harvey Road intersection . This tract generally slopes to the south with an approximate maximum grade of 2.50%. The site is currently vacant and unimproved with native grasses, weeds, small brush and heavily wooded trees . The natural drainage of the site is by sheet flow to the south and into Wolf Pen Creek, being approximately 200 feet from the site . Thence runoff is carried by the confluence of Wolf Pen Creek to Carter Creek. This site is in the Wolf Pen Creek sub-drainage basin , which is a part of the Carter Creek drainage basin . The policy of the City of College Station is to encourage the rapid conveyance of stormwater through and out of the city within the primary system as stated on page 8, paragraph 3 of the cities Drainage Poli cy & Design Standards . This site is on the primary system of Wolf Pen Creek as shown on Figure II-I , (Carter Creek Drainage Basin). Therefore, no runoff will be detained on the proposed site and the post-de velopment runoff from the site will be directed to Wolf Pen Creek. DRAINAGE AREA DESCRIPTION The pre-development drainage area consists of 0 .742-acres of land . The post- de velopment drainage area will consist of the same site and total acreage, but runoff coefficients will change due to the development. Impervious areas will be introduced by the 1,406 square foot building and from the concrete parking area and driveway . Runoff from the building rooftop will be channeled into the proposed parking lot. Also , runoff collected from the landscaped areas will drain into the parking lot. The runoff will then be collected by a series of grate inlets and pipe a through storm sewer system to poin t off the proposed site into Wolf Pen Creek . Thence runoff will continue on by th e abo ve 2944-000009 Drainage Report .doc Drainage Report -3 1 '\ W~st Wo lf P~n Creek Sonic Drive-In Drainage Reo ort Municipal De ve lopment Group mentioned natural drainage pattern . The results of the storm sewer system are further illustrated and supporting calculations shown in the section, "Results". The post-development drainage will consist of two sub-drainage basins . The western portion of this site , (Drainage Basin Al), will collect runoff primarily from the proposed parking lot and drain to the southeast. The eastern portion of the site , (Drainage Basin A2), will collect runoff from the proposed building and parking lot and drain to the southeast . Runoff from the parking areas will consist of properly sized grate inlets to insure that the water depth in the parking lot does not reach above 6" during the 25~year rainfall event. The results of the outlet design are further illustrated and supporting calculations shown in the section, "Results". Also a typical detail is shown in Section #5, "Drainage Details ". DRAINAGE CALCULATIONS The drainage calculations, data and miscellaneous information are presented in four basic sections : I . Mapping -Miscellaneous drainage basins and detailed mapping of the area. II. Drainage Area : Pre-Development -Contains the calculations for the amount of runoff prior to the development of the site . ill. Drainage Area: Post-Development -Contains the calculations for the amount of runoff after the proposed development. IV. Hydrographs -Comparisons of Pre and Post Hydrographs of the entire site . V . Proposed Storm Sewer -The calculations and requirements for the proposed storm sewer through the site to discharge runoff into Wolf Pen Creek. VI . Proposed Fill & Grading -Hydraulic computations verifying that the fill on the project site will not have adverse affects to Wolf Pen Creek. VII. Drainage Details -Construction details of required drainage structures . The drainage area calculations are summarized accordingly using the Rational Method: (Q=CIA) where "Q" is the runoff in cubic feet/second, "C" is the runoff coefficient , "I" is 2944-000009 Drainage R ~po rt .d oc Drainage Re port -4 West Wolf Pen Creek Sonic Drive-In Drainage Report Municipal Development Group the storm intensity in inches/hour for each selected frequency , and "A" is the drainage area in acres . We will assume a minimum ten-minute time of concentration for all calculations . The selected frequencies will be 2, 5 , 10, 25 , 50 , 100-year rainfall events . Tabulations of the pre-development and the post-development hydrographs of the drainage areas are provided . The hydrographs are based on the standard SCS unit hydrograph with time to peak discharge set to equal the time of concentration and the total base time set at 3 . 00 times the time of concentration. Grate flow calculations were determined from the following orifice flow equation (Q = CA(2gh)112), where "C" is the orifice coefficient, "A" is free open-area in ft 2, "g" is constant at 32 .2 ft/sec 2 , and "h" is the head in feet , on the grate. Pipe flow calculations were computed using Manning 's formula , aided by the program StormCAD vl.0 . Pipe flow calculations assumed full flow capacity when solving for slope, velocity and discharge rate . RESULTS From the drainage calculations the following results were determined : + Detention Calculations : As discussed earlier, the City of College Station policy is the rapid conveyance of stormwater at a site on a primary system . Since the proposed site drains to Wolf Pen Creek, no detention should be kept on-site . This is done in order to keep from stacking peaks of the primary creek and the discharge of runoff off of the site . Justification of no detention to this site was made by the comparison of time of concentration, (T c). The approximated Tc of Wolf Pen Creek, to the proposed site , is 35 minutes . This Tc assumed an average velocity of 4 .0 ft/sec and 8,500 ft of travel to the project site . The minimum T c of the site allowed without detention is 10 2944-00000 9 Dra in age Report.d oc Drainage Report -5 West Wo lf Pe n Cr eek Sonic Drive-In Drainage Re port lvlunici pal Development Group minutes . With detention, the T c of the site increases to approximately 20 minutes . Therefore. detention on-site would increase the overall peak of Wolf Pen Cr eek. + Proposed Storm Sewer: Sub Drainag e Basin Al & A2 w ill be drained by g rate inlets placed inline with the proposed storm sewer sy stem. The grate inlet will have a capacity equal to that of the 100-y ear rainfall ev ent with a half-foot of h ead . A Neenah grate model R-1878-B3G or approved equal will be used for both grates . "-< Capac ity= Gravity , g = -Capacity= Gravity , g = GRATE INLET for SUB-BASIN A1 GIVEN -CAL CU LA TED . . 100-~RAINFALL EVENT) 4.237 cfs -./ Depth= 32.2 FT/sEc Free-open Area= GRATE INLET for SUB-BASIN A2 CALCULATED ··--_,_.._1_00-YEAWRAINFALL EVJ::NT) 4 .036 cfs ./" Depth = GIVEN FT 32 .2 l sEc Free-open Area= 0.50 ft 1 ~24 tt2 0 .50 ft 1~19 tt2 From Section #5 the sizing of the proposed storm sewer was determined . The proposed storm sewer was anal y zed with the calculated water surface elev ations from the N .D .M . flood study . Below is the data summarizing the proposed storm sewer sy stem . P-5 P-4 P-3 P-2 P-1 Outlet 2944-000009 Drainage Report.do c l?ROPOSED STORM SEWER (25-YEAR RAINFALL EVENl) TYPE DISCHARGE . VEl:.OCITY. . (cfs) 18" R.C .P . 7.501 4.24 18" R.C.P . 3.590 2 .03 18" R.C .P. 7 .010 3.97 24" R.C .P. 10 .496 3.34 30" R.C .P . 21.889 4.46 21 .889 4.46 Dra in age Report -6 West Wo lf Pen Creek Sonic Drive -lo Draina ge Report Muni ci pal D eveiopment Grou p PROPOSED STORM SEWER ' (100-YEAR RAINFALL EVENT) PIPE TYPE DISCHARGE VELOCITY (cfs) (ft/sec) ···. P-5 18" R.C.P . 8.853 5 .01 P-4 18" R.C .P . 4 .237 2.40 P-3 18" R.C.P. 8 .273 4 .68 P-2 24" R.C .P . 12.387 3.94 P-1 30" R.C .P . 25 .834 5 .26 Outlet 25 .834 5.26 + Proposed Fill & Grading : From the N .D .M . study the water surface elevation, channel velocity and cross-sectional area for Section No . 154 .00 was interpolated . From the formula Q=AV the following assumptions were made : );;>-The quantity of discharge, (Q), would not change significantly . );;>-The velocity that was interpolated originated from the N .D .M . study . These base velocities from the N .D .M . study are velocities experienced within the floodway of Wolf Pen Creek. Since fill will only occur outside of the floodway the velocities would not change . );;>-The cross-sectional area would be the onl y variable to the flow geometry and characteristics in Wolf Pen Creek, so long as fill only occurs outside of the floodway . From this assumptions the change in cross-sectional area from fill on the project site could be converted into additional depth . This raise in water surface elevation would therefore account for the change in cross-sectional area . Below are the following results : PROPOSED FILL & GRADING EFFECTS , ~iNTERPOLA TED ·-CHANGE : . STORM . AREA W.S.E. W.S.E. :~ , (yr) • -(sQtt} ft) ft) 2944--000009 Drainage Report .doc 10 50 100 500 1063 .57 1233.16 1338 .85 1564.36 277.52 278 .04 278 .35 278 .95 0.17 0 .29 0 .37 0 .39 Drainage Report -7 We st Wo lf Pen Creek Soni c Dri ve-Jn Drainage Reoon Municipal Development Group This method of checking the change in water surface elevation maybe vary simplistic in nature, but it is a good method of checking whether the change in cross-sectional area will have an drastic impact on the water surface elevation. From our calculations the findings showed that the raise in water surface elevation are be negligible . 2944-000009 Drainage Repon.doc Drainage Report -8 SECTION#! MAPPING - I ---------·-~.\ ,'f {'DAAl"1~~E \A-e,u.:_) A'2..£.~ VAL\J £ ~t-l (o.c./ Cc.") A 0,"1"{'l. o.~s Pd 0.1'SC O.°l '5 ft1.. o.~z. C> .°1'5 SECTION#2 DRAINAGE AREA PRE-DEVELOPMENT SECTION #2 DRAINAGE AREA -PRE-DEVELOPMENT GENERAL INFORMATION Descripti on : Dra inage area of site before development. Drainage Area (A PRJ = 0 .742 acres TIME OF CONCENTRATION CTc) GIVEN Maximum Travel Distance (D PRE) Veloc ity of Runoff (VpR J = 320 ft ft 1 .00 fsec Coefficient of Runoff (CpRJ = 0 .38 **NOTE : Minimum Tc allowed = 1 O min . 2 YEAR FREQUENCY , RATE OF DISCHARGE (Q) Coefficient (e) = 0 .806 Coefficient (b) = Coefficient (d) = 65 8 5 YEAR FREQUENCY , RA TE OF DISCHARGE (Q) Coefficient (e) = 0 .785 Coefficient (b) = Coefficient (d) = 76 8 .5 10 YEAR FREQUENCY, RATE OF DISCHARGE (Q) Coefficient (e) = 0.763 Coefficient (b ) = 80 Coefficient (d) = 8 .5 25 YEAR FREQUENCY , RA TE OF DISCHARGE (Q) Coefficient (e ) = 0 .754 Coefficient (b) = Coefficient (d) = 89 8 .5 50 YEAR FREQUENCY, RA TE OF DISCHARGE (Q) Coefficient (e) = 0 .745 Coefficient (b ) = Coefficient (d) = 98 8.5 100 YEAR FREQUENCY, RATE OF DISCHARGE (Q) Coefficient (e) = o. 73 Coefficient (b ) = 96 Coefficient (d) = 8 2944-000009 Deten tio n Facilities Evaluation.xi s RESULT T C{PR E) = 5 .3 min . Rainfall Intensity (1 2) = 6.327 in /hr ',,:a.:' ....•.... ·,.: .. ' .. '.'.! . .::,.,'.•'.r= .. '.,' .. '.,' .. '.,'.==.•'.•.•'.i .... •.,..r.'.•· .. '. •••<•:t:J?''tt•>t •t't:tr·:ri.' ...•. L.•.•.z.:.·.····;·~······.•.•.s.·.•.·.•.•.·.•.•.•.¢.·.·.'.•.t:.·.·.•.s.•.'.•.'.•.•.•.•.•.••.•.·•.••.••.•• ..... ·:·:···:·:·:·:·:-:-:·:·:·:-:·:·:·:::-:::::::::::·:·:::::::::·:::;:;:::::::;:;::::::::::: Rainfall Intensity (1 5) = 7 .693 in /hr •:9i l:ffi ::.::;•::::':::.::, ·:,,:,·: .••.. :::.]::•:.::••.I.•••••@,:j•!~•••*=*=••il ••:i• Rainfall Intensity (1 25 ) = 9.861 in/hr •9.lMa••· '••'•':: : : :::: ,. ••••:i •·i••••:•::::::::.:::::•:::::i,ii•i~!P.ii•i'.!it::•i:•::i: Rainfall Intensity (1 50) = 11 .148 in /hr .•.tJ.•.•.•.·.· .. •.·.~.··.&.'.•.•.•.•.=.•.•.•.•.•.•.• ?:•:::::::::::;::::'=:::::::::::::?+:::: , •••••• ::::::::: :•tti l .1.•.·.·.•.•.s.: ..... '!Kdt.Mm::•t ~ ·.·.·:--:·.·.·.·:·:·.·:·:·:·:·:·:·:·:-:.;-:-:-:.;-:-:-:-: -:.;-:-:-:-:-:-:-:-:-:-:-:-:-:·.·.·.·.·.·.·.·.·. ·.·.·.··:·:···:··-:-:-:-:-:-:-:-:-:-:-: Rainfall Intensity (1 100) 11 .639 in/hr :l ~••iif••·::.::]::::::::::·:::•::m•:••n • : :··:r:'::••·••:::::-::1::,::i1=~9.~·:1~1m::r SECTION#3 DRAINAGE AREA POST-DEVELOPMENT SECTION #3 DRAINAGE AREA -POST-DEVELOPMENT GENERAL INFORMATION Desc ri pt ion : Dra inage area of site after development Drainage Area (A 1) = 0 .380 acres (developed area ) Drainage Area (A2J = 0.362 acres (developed area) TIME OF CONCENTRATION CTc> GIVEN Max imum Travel Distance (D 1) = Velocity of Runoff (V 1) = Coeffic ient of Runoff (C 1) = Max imum Trave l Distance (D 2) = Velocity of Runoff (V2J = Coeffic ient of Runoff (C 2J = 320 ft ft 2.75 f sec 0.95 270 ft ft 2.75 f sec 0 .95 **NOTE : Minimum Tc allowed = 1 O min . 2 YEAR FREQUENCY. RA TE OF DISCHARGE (Q) Coeffic ient (e) = Coeffic ient (b) = Coeffi ci ent (d) = 0 .806 65 8 5 YEAR FREQUENCY. RA TE OF DISCHARGE (Q) Coefficient (e) = Coeffi ci ent (b) = Coe ffici ent (d) = 0 .785 76 8 .5 10 YEAR FREQUENCY. RATE OF DISCHARGE (Q) Coe ffi cient (e) = Coeffic ient (b) = Coeffic ient (d) = 0 .763 80 8 .5 25 YEAR FREQUENCY. RA TE OF DISCHARGE (Q) Coeffic ient (e) = Coeffic ient (b) = Coefficient (d) = 0 .754 89 8 .5 50 YEAR FREQUENCY. RA TE OF D ISCHARGE (Q) Coeffic ient (e ) = Coe ffi cient (b) = Coe ffi cient (d ) = 0 .745 98 8.5 100 YEAR FREQUENCY. RATE OF DISCHARGE (Q) Coe ffi cient (e) = 0 .73 Coeffic ient (b) = Coefficient (d) = 2944-000009 Detent ion Facilities Evaluation.xis 96 8 RESULT Tc1 = 1.9 m in. TC2 = 1.6 min . T c(Pos n = 3 .6 min . Rainfall Intensity (1 2) = 6 .327 in/hr Q AREA 1 = 2 .303, cfs Q AREA 2 = 2 .194 cfs ·=&·=·.,.,,, ... ,.,,,,.,,.,,,, :::::=:=:·=·=:==== ::::::=::::::::=== .. ,,,,,,,.,.,., =•.==.:•. ··-..···1 :::;1:aii ~··-.··: )~~~.~~~ffift~? ~~;:~r ... >\::: :::::::::::::= :::::=:=:=:~:r:::::== ·=·:·:·.·.·.·.·.·.·.·.·.-~~~:i:: ~J.;;>. Rainfall Intensity (1 5) = 7 .693 in/hr Q AREA 1 = 2 .800 cfs Q AREA 2 = 2.668 cfs :m:,a.:.:::. :::: ::: :t11 tr =::: ,:::::::.:::=:·ri:~~~!: m .l•:=:: Rainfall Intensity (1 10) = Q AREA1 = 8.635 in /hr 3 .143 cfs Q AREA 2 = 2 .994 cfs ::lii·:a:::·i:·,• ::.:.:::=:::::::::::=i:rn::::i: ::::·:.·:? .:.::::::I:·I:·!*ti~:·:1~= · :::::: Rainfall Intensity (1 25) = Q AREA 1 = in/ 9 .86 1 hr 3 .590 cfs Q AREA2 = 3 .420 cfs :1~=a:·: :::.:::.r::.::::::r=·:·.•=·,:.:==:=.:·::·=:=:•::::::=::,:·•:•=:·:·::::·:~4mm ::~:::::1::::: Rainfall Intensity (1 50) = Q AREA 1 = Q AREA2 = 11 .148 in /hr 4.058 cfs 3.866 cfs ·.·.·.·-:-:-:-:-:·:·:·:·:·:·:·:·:··· ····:·:·:::::::::::::::::::::::::::::;::::::: ·:-:;:~:~:~:~:~:~:\ ·.·:·:·:·:::·:·:;;·-6:~;;=:=::::::f·:-:.;;:: ....... . '.:'.:""".: ... ·.··.·.· .. · ... ''.''."'''.'.=· ... •·.:.~.··.·.•.:.•.. ,.,.,.,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, ,,,,,,,,, .,,,, , .. ,,,.,,,.,, ::::::::::::'::::,:i~;;..~\c $::;:::::::::::: ~ ::::::::::::::::;:;::::::::::::::::::::::::::::::::::::::::::::::::::.;.;. ·:·:-;.;.·.:-:·:-:·:· Ra i nfall Intensity (1 100) 11.639 in/hr Q AREA 1 = 4 .237 cfs ~ Q AREA 2 = 4 .036 cfs :,(lfaij •!# ::: :£ :::;:,.,}/] ::::: :::;·:=:·:::::::: ::::= ::: ::::::16~!;~ =:Et~:::: )l SECTION#4 HYDROGRAPHS SECTION #4 -HYDROGRAPHS Chart 4 2-YEAR HYDROGRAPH 0 10 ID Post-Development D Pre-Development HYDROGRAPHS Chart 4 TIME (min) 20 30 SECTION #4 -HYDROGRAPHS Chart 5 5-YEAR HYDROGRAPH 0 10 mJ Post-Development CJ Pre-Development HY DROGRAPHS Chart 5 T™E (min) 20 30 SECTION #4 -HYDROGRAPHS Chart 6 10-YEAR HYDROGRAPH ?--~~~~~~~~~-.-.~~~~~~~~~~~~~~~~~~~~ I 4------- 3----- 2--- 0 0 10 Im Post-D ev elopment 13 Pre-D evelopment ' HYD ROG RAPHS Chart 6 TIME (min ) 20 30 SECTION #4 -HYDROGRAPHS Chart 7 25-YEAR HYDROGRAPH 0 10 ml Post-Development EJ Pre-Dev elopment i HY DROGRAPHS Chart 7 TIME (min) 20 30 SECTION #4 -HYDROGRAPHS Chart 8 50-YEAR HYDROGRAPH 0 0 10 Im Post-Development 13 Pre-Development · HYDROGRAPHS Chart 8 TIME (min) 20 30 SECTION #4 -HYDROGRAPHS Chart 10 100-YEAR HYDROGRAPH 0 10 •Post-Development l!I Pre-Development HYDROGRAPHS Chart 10 TThf E (min) 20 30 SECTION#5 PROPOSED STORM SEWER 281 .00 2 80 .00 . ·--· --- 279.00 278 .00 ·---------- 277.00 276.00 . -----------_,_ 25 yr= 275 58 rt 275 .00 ·---·- 274 .00 1 Wo lf Pen Creek TAILWATER --------------c----·----·---------- ~ 'fl' ' ~· ~ ~-1--µ~ ~ i.--l-1 J .~ ~ L.--- I f-~------,__ ------------ l = 0.3694Ln(x) 274.39 '?" ((: ,_ l----··----------'l--i:;.....- rt> i.--i.--i r- L---~· I--' i,-.~ i--i-- L.---~> --____J .~ ~ n ~ <%- 10 RAINFALL EVENT (YEAR) -t-r-r--- "" ,~~ ~ _..,. .--µv--- 1--I-"' ~ . . ' .>. "._:> 100 _4 ~ --~ i.--l.-.JI L--- -->-- .. ~ 'V' ~ l,..--i l. L---~~ --i.--...:>. l U! v -- -- --- ---- __10_0Q ____ -- +section No . 145.60 •Sect ion No. 156.40 &Sectio n No . 147 .60 Sonic Parking 1-4 [] P-4 Project Title: 000009-2944 Proposed Sonic i :\projects\000\29441294411 rb.stm 10/02/98 10:06:19 AM 1-3 KONA RESTAURANT P-3 25-Year Ra inf all Event MUNICIPAL DEVELOPMENT GROUP Haeslad Methods. Inc . 37 Brookside Road Waterbury , CT 06708 (203) 755-1666 P-1 1-5 Outlet Wolf Pen Creek Project Engineer: Rabon M etcalf StormCAD 111 0 Page 1 of 1 ---~let: I 1m :1. ~1~:_1=2_ --tumP. v-ln:a. 1-I 'i n : 276 .500 ft ~ F im : 276.21 0 ft c,L mp: 271 .220 ft ic ump : 267 . 463 ft .v / -,_- / -----· +------- ~ ~utlet: Outlet irn · 2Z1 QQQ ft ump: 266 .000 ft L__---- --0+00 -----,.......... - c--· -----p,ipe · P-1 o+~ Invert: 267 .lrt80rt Dn Invert: 266 .000 ft Length : 117 .00 ft Section Size : 30 inch Project Title: 000009-2944 Proposed Sonic i :\projects\000\2944\294411 rb .stm ·--------1-- Pipe : P -2 '20 ft Up Invert: 271 . Dn Invert· 270 Ll;n ft 1 +l.bngth : 77 .00 ft.t.nn S'~ction Size : 2if m:n -=· Pip1 ~p ._,, Len Sec --- Station ft -- i : P-3 nvert: 272.61 0 ft nver t. 271 . 72o-ft ;1th : 89 .00 ft ion Size : 18 inch ~- 2+50 MUNICIPAL DEVELOPMENT GROUP 3 ( ( .500 ft 272610ft -- I I ~e:P ,________ p lfiVe On lnve Len~th : Sec ion - 3+00 10/02198 10:06:41 AM Haestad M e thods , Inc . 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 278 .00 ~·~let: 1-4 F im : 277 . 5 00 ft .s~e .0:0 ·-!:: _ump_;_Zl. 3 --- - 4 ft:273 ~50Crff" -.... rt: 272 .610 ft 89 .00 ft Size : 18 inch 3+50 274 .00 272.00 270 .00 268 .00 266 .00 4+00 E lovation ft Project Engineer: Rabon Metca lf StormC AD v1 .0 Page 1 of 1 Node Report Node Inlet Inlet Inlet Inlet Upstream System System Total Discharge Velocity Ground Area c CA T C Flow Flow Intensity Watershed (cfs) (ft/s) Elevation (acres) (acres) (m in) Time Time (i n/hr) (CIA) (ft) (min) (min) (cfs) 1-5 0 .00 0 .00 0 .00 0 .00 0 .00 0 .00 0.00 0 .000 7 .501 4 .24 276.600 1-4 0 .00 0 .00 0 .00 0 .00 0 .00 0 .00 0.00 0 .000 3 .590 2 .03 277.500 1-3 0 .00 0 .00 0 .00 0 .00 0 .73 0 .73 0 .00 0 .000 7 .010 2 .03 277.500 1-2 0 .00 0 .00 0 .00 0 .00 1 .10 1.10 0 .00 0 .000 10.496 3 .34 276.500 1-1 0 .00 0 .00 0 .00 0 .00 1 .49 1.49 0 .00 0 .000 21 .889 4 .46 276.200 Outlet NIA N/A N/A N /A 1 .93 1 .93 0.00 0 .000 N/A 4.46 271 .000 Project Title : 000009-2944 Proposed Sonic i:lprojects\0001294412944t1 rb .stm MUNICIPAL DEVELOPMENT GROUP 10/02198 10:07 :04 AM Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Rim Sump Elevation Elev atio n (ft) (ft) 276.600 271 .6 7 0 277.500 2 73.500 277.500 272.6 1 0 276.500 2 71 .220 276.200 267 .463 271 .000 266.000 Project Engineer: Rabon Metc alf StonmCAD v 1 .0 Page 1 of 1 Pipe Report Pipe Upstream Downstream Discharge Length Constructed Average Section Roughness Capacity Upstream Downstream Upstream Node Node (cfs) (ft) Slope Velocity Size (cfs) Invert Invert HGL (ft/ft) (ft/s) Elevation Elevation (ft) (ft) (ft) P-5 1-5 1-1 7.501 72.00 0 .010000 4 .24 18 inch 0 .014 9 .753 271 .670 270.950 276.578 P-4 1-4 1-3 3 .590 89.00 0.010000 2 .03 18 inch 0 .014 9 .753 273.500 272.610 277.029 P-3 1-3 1-2 7 .0 10 89.00 0.010000 3 .97 18 inch 0 .014 9 .753 272.610 271 .720 276.908 P-2 1-2 1-1 10.496 n .oo 0 .010000 3 .34 24inch 0.014 21 .005 271 .220 270.450 276.344 P-1 1-1 Outlet 21.889 117.00 0.012504 4 .46 30inch 0.014 42.588 267.463 266.000 275.966 Project Title: 000009-2944 Proposed Sonic i:\projects\000\294412944t1rb.stm MUNICIPAL DEVELOPMENT GROUP 10/02/98 10:07:21 AM Haestad Methods , Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Project Engineer: Rabon Metcalf StorrnCAD v1 .0 Page 1 of 1 Sonic Parking 1-4 P -4 1-3 G-·~~-~~~~~~----t-.1 Project Title: 000009-2944 Proposed Sonic i :lprojects\0001294412944t1 rb .stm 1 0/02198 11 :20 :43 AM KONA RESTAURANT P -3 I- 100-Year Rainfall E vent M U NI C IPAL DE V ELOPM E N T GROUP Haestad Methods, Inc . 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 P -1 1-5 O utlet Wolf Pen Creek Projec t Engineer : Rabon Metcalf StormCAD v1 .0 Page 1of1 ~ l.1 "-•· •-? V' 1 1~1 -=1 ~i n : 276 .500 ft ~· J im : 276 .2< IQ ft <~l mp: 2 7 1 .220 ft ~ump : 267 . 1463 ft v / ~ ,__~ -4 -----------------··----.__- >utlet: Outlet Pip1 !im · 271 000 ft lJP ump : 266 .000 ft ~ ,__.... un Le n -----S ec ~~---!--P i p e : P -2 ._-Up Invert: 271 . '20 rt ·--·--·-·--··---Dilln'l.el1:.2Z.O~l5.0 _ _tt ·-----·----- 0 +00 f',lpe · P -1 o +~ Invert: 267 .~ Dn Invert: 266 .000 ft Length : 1 1 7 .00 ft S e ction S ize : 30 i nch 1 J..twgth : 77 .00 ft,t·nn ~S'~ction S ize : 2 4" m:n Station ft -;· ~ i,:n :" :; lUID'"' -·-------- : P -3 nvert: 272 .61 Oft 11ve1 t. 27 1. 720 ft ~th : 89 .00 ft ion Size : 18 i nch 2+50 Project Title : 000009-2944 Proposed Sonic i :\projects\0001294412944t1 rb .stm MUNICIPAL DEVELOPMENT GROUP - 77 .500 ft ?7? R1n ft I I P IE_e : P ~--·--Up lmTe Dn lnve LenP.th : Sec ion ------ 3 +00 10/02/98 11 :21 :13 AM Haestad Methods, Inc . 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 278 .00 11 ~let : 1-4 im : 277 . 5 00 ft .s~e .no ~ ,...,n·?7' - -- 4 ff'.273 :500 ft--·- rt: 272 .610 ft 89 .00 ft Size : 18 i nch ·- ----------·- 3 +50 274 .00 272 .00 270.00 268 .00 2 66.00 4 +00 E l e vation ft Project Engineer: Rabon Metcalf StormCAD v1 .0 Page 1 or 1 Node Report Node Inlet Inlet Inlet Inlet Upstream System System Total Discharge Velocity Ground R im Sump Area c CA TC Flow Flow Intensity Watershed (cfs) (ft/s) Elevation Elevation Elevation (acres) (acres) (min) Time Time (in/hr) (CIA) (ft) (ft) (ft) (min) (min) (cfs) 1-5 0 .00 0 .00 0 .00 0 .00 0 .00 0 .00 0 .00 0.000 8 .853 5 .01 276.600 276.600 271 .670 1-4 0.00 0 .00 0.00 0 .00 0 .00 0 .00 0 .00 0 .000 4 .237 2 .40 2n.5oo 2n.5oo 273.500 1-3 0 .00 0 .00 0 .00 0 .00 0 .62 0 .62 0 .00 0 .000 8 .273 2.40 2n.5oo 2n.5oo 272.610 1-2 0 .00 0.00 0 .00 0 .00 0 .94 0 .94 0 .00 0 .000 12.387 3 .94 276.500 276.500 271 .220 1-1 0 .00 0 .00 0.00 0 .00 1 .26 1.26 0 .00 0.000 25.834 5 .26 276.200 276.200 267.463 O utlet NIA N/A N/A N /A 1 .63 1 .63 0 .00 0 .000 N/A 5 .26 271 .000 271 .000 266 .000 Project T itle: 000009-2944 Proposed Son ic Project Engineer: Rabon Metca lf i:\projects\000\2944\2944t1 rb .stm MUNICIPAL DEVELOPMENT GROUP StormCAD v1 .0 10/02198 1 1 :22:00 AM Haestad Methods , Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755-1666 Page 1 of 1 Pipe Upstream Downstream Discharge Node Node (cfs) P-5 1-5 1-1 8 .853 P -4 1-4 1-3 4.237 P-3 1-3 1-2 8 .273 P-2 1-2 1-1 12.387 P-1 1-1 Outlet 25.834 Project Title : 000009-2944 Proposed Sonic i:\projects\000\294412944t1 rb.stm Pipe Report Length Constructed Average Section Roughness (ft) Slope Velocity Size (ft/ft) (ft/s) 72.00 0 .010000 5 .01 18 inch 0 .0 14 89.00 0 .010000 2.40 18 inch 0 .014 89.00 0 .010000 4 .68 18 inch 0 .0 14 77.00 0.010000 3 .94 24inch 0 .014 117.00 0 .012504 5 .26 3 0 inch 0 .014 MUNICIPAL DEVELOPMENT GROUP 1 0/02198 11 :22:25 AM Haestad Methods , Inc. 37 Brookside Road W aterbury, CT 06708 Capacity Upstream Downstream Upstream (cfs) Invert Invert HGL Elevation Elevation (ft) (ft) (ft) 9 .753 271.670 270.950 276.793 ' 9.753 273.500 272.610 277.308 9.753 272.610 271 .720 277.140 21 .005 271 .220 270.450 276.468 42.588 267.463 266.000 276.118 (203) 755-1666 Project Engineer: Rabon Metcalf StormCAD v1 .0 Page 1 of 1 SECTION#6 PROPOSED FILL & GRADING SE CTION #6 -PROPOSED FILL GRADIN G Nathan D. Maiers Study Water Surface Elevat ion Given Given Interpolated Section No. 145.60 ·Section No. 156.40 Section No. '154.00 _ _,,,~) . -(ft) (ft) 10 274 .86 278 .37 277 .52 50 275.43 278 .88 278 .04 100 275 .72 279 .19 278 .35 500 276 .30 279 .80 278 .95 Channel Velocity . Gtv~n.. Given Interpolated -Section No ~ 145.60 ' Section No. 156.40 ~ < , ~ ' ~ Section No. 154.00 ft) (ft) (ft) 10 6 .60 3 .95 4 .59 50 6 .29 4 .34 4 .8 1 100 6 .31 4 .58 5 .00 500 6 .30 5 .06 5 .36 Cross-Sectional Area Gjven Given Interpolated SeCtioh No'. 145.SO:. Section No. 156.40 Section No. 154.00 ft ft) (ft ' 10 863 .24 11 2 7 .67 1063 .57 50 1124 .19 1268 .03 1233 .16 100 1262.33 1363 .33 1338 .85 500 1568 .69 1562 .98 1564 .36 Sect ion= 146 .5 156.4 154 Qual ity = 0 .757575758 2944-000009 Proposed Filling.xis 281 .00 280.00 . ---·---··--~---~--- 279.00 z 278.00 0 . -·------· ---t-----------,.... f-4 ..-~ ¢: ;;;... ,,_, r,.;i ~ 277.00 r,.;i 276 .00 . -------- 275.00 ' ----·-· ~ - 274 .00 Wolf Pen Creek-Water Surface Elevation --.. -------·-------· --·--- --i---·----·-- .._qi . ~c . l,...-- VG 'ff µv--- -~ i-- & _.., [' b .~~ l,...--~ ~G'(? l.---.___--~ • I r$ ~J----- ~ "" ~ i-- -·---~'lr--------i.---~ IL --------·--- ·~ v---[.--- j - v r 0.3684Ln(x) it 276 .6~ -----~---------~--~ ~ ~ ""~ ,-i--~ ~ i.--( ~ l---.:>,>. ---( ----t----·------· . ...---- ~ l <%> 10 l'V RAINFALL EVENT (YEAR) 100 "1 ~ ~ I ~ '°'q_ ~':> ~ ~ ~ ~ _...., ~-( <b ~ ------ -- --- ___ j_QQ{)__ __ +section No. 145.60 •Section No . 156.40 .&Sectio n No . 154 .00 1800.00 1600.00 1400.00 . - 120 0 .0 0 z 0 1000.00 . -------·-· ------------·-·--·· -- ~ ~ -~ i:: > -~ 800 .00 ioJ ~ 600 .00 400 .00 200 .0 0 0.00 1 Wo lf Pe n Creek-Cross-Sectional Area ··- r>.. ··---------··-------~ ~ ::::: b• i- ~ ~ ~ i- .<i · .. __... ~ l i.,.. ~ ~ ./ ...... .~ ~ ~ ~ ' v l/ 77 ·.., Ir --~-. ·-·--·······--J " ~ '9 : 751.6! . '{~ 'it" --· -·----· ·-------,___ -·-- 10 --~ RAINFALL EVENT (YEAR) .~ ~ ~ =~ ..... ..... i..- re I:> ·u>ui ---·-·--·----·- -->-· 10 0 .... 4 ~ ~ !_.) 7~ --.. . -· ---•··· ·-~ q,'b IJ.• ~ b ·6''9 - ~ -· ,_ ~-- 1000 ·-- +section No . 145 .6:1 •secti on No. 156.40 A_S:ctio n ~~--I ~4 .00 Wolf Pen Creek-Channel Velocity •t ~r~~~~-r~~t--1~~.~~-t-+~~,.._~~~+-~-+-~t-.J .. 6 .00. -···---·----·-· ·----·------<:! P:::·-'9 --~i~~-------------~-~ ------·--7 v -5.00 ..-----r----r---r--r--r-1-1--+"--1,)-'nr-----t l~ I ~----- "' --i----~~ b<I ~-- ...--b< -~f--1~ ...- b ~~-- ~~ _r JI ,,._;p L----- 4 00' *-=,,_..---~-.. -··---~-----------~ -----------1---1-· -··-. ----~-· --·-----· . -· ·---------· -----------------·--.,.--- 3 .00ol-----l----l---+-+---l--l-1!-f-Y~~~o~.1~9~86~L-n'(x~)~~4 .~09~5c;;l--l -+---+--r-+-i-IH-----r----r---t--i--i--r-1t1 2. 00 1 -----j------l--+----1---t--t--t-t--t-----t----;-·---~ -··t--11--+-t-t------;----r---;---;---r--;--y-·TO 1. 00 • -----.----t---+-+-+-+-lr-+--t------ o.oo+-------.i.....--..i........i.--.i..... ..... ....._...._. ______ .... __ ....., __ ...... ..._..._....., .......... ____ _.... ____ .._ __________ -. 10 RAINFALL EVENT (YEAR) 100 1000_ ___ ··--~ection No . 145.60 ect ion No . 156.40 ___ c.cti_on No . 154 :_?.~ SECTION#7 DRAINAGE DETAILS R-1878 Series Frames Heavy Duty Lids, Grates These shallow frames are suitable for use in thin or deep con- crete slabs. All sizes of frames are reversib le and can be installed with flang e ot base or top. Sµecify : 1. Catalog numbe r. 2. To be installed with flange ct base or fop. Square Catalog Solid lid R-1878-A IL R-1878-A2l R-1878-A3l R-1878-A4l R-1878-ASL R-1878-A6L Number Open Grate I R-1878-AlG , R-l 878-A2G I R-1878-A3G R-1878-A4G R-1878-ASG R-1878-A6G R-1878-A7l R-1878-A7G R-1878-A8l R-l 878-A8G R-1878-A9l R-1878-A9G R-1878-A 1 Ol * R-1878-A 1 OG* Rectangu lar R-1878-Bl l R-1878-B2l R-1878-B3L R-1878-B4l R-1878-BSL R-1878-B6L R-1878-B l G R-1878-B2G R-1878-B3G R-1878-B4G R-1878-BSG R-1878-B6G Dimens ions in inches A B c 13 34 x 1334 l 'h 12 x 12 18 x 18 l 'h 16x 16 20 x 20 l 'h 18 x 18 1 2 l~x21~ l'h 20 x 20 23!12x23Y21'h 22x22 25~x25~1'h 24x24 27'h x 27'h 1 'h 26 x 26 29 'h x 29'h l 'h 28 x 28 31'4x3rn l 'h 30x30 37 x 37 1 'h 36 x 36 D E F 14xl4 18x18 4 18'hx18'h 22x22 4 2014 x 2014 24 x 24 4 22 x 22 1'26 x 26 4 24 x 24 28 x 28 4 26 x 26 30 x 30 4 28 x 28 32 x 32 4 2934 x 29'4 34 x 34 4 32 x 32 36 x 36 4 37'h x 37'h 42 x 42 4 14x20 l'h 12x1814'hx 20 'h1 Bx244 13'h x25'h l 'h 12x24 13 ~x 25 ~ 18x30 4 19'h x 25'h l 'h 18 x 24 19 3.4 x 25 "4 24 x 30 4 19'hx3l'h l'h 18x30 20x32 24x36 4 19 3.4 x 37~ 1 'h 18 x 36 20 x 38 24 x 42 4 25 'hx3l'h l'h 24x30 25 34x 3l l;• 30x36 4 G 1 xS Y2 1 Y.x 4 Y. 1 "/,.x 3 * 1Y.x 3 !/i 1Y2x 6 !/i 2*x 7)4 lxS lYsxS!li lx6* 1¥.x 3 Y2 :;4 x5 !/i l x4Y2 %x 5 2x5 2x5 l*xS R-1878-B7l R-1 878--B7G R-1878-B8G* R-1878-B9G * R-1878-B l OG* 25 Jl2 x37Y2 l 'h 25 3.4 x 49~ l 'h 31 3.4 x 3734 l'h 3l'h x 49'h l'h 24x 36 24x48 30 x 36 30x 48 26 x 38 26 x 50 32 x 38 30 x 42 4 l *x S . R-1878-S8L * R-l 878-B9l * R-1878-BlOL* 3P" x 49~ 30 x 54 4 l5/i 6 x6 13fi 6 36 x 42 4 l*x4% 36 x 54 4 lY2x4:;4 •Cover in two pieces.. R-1879 Series Frames Light Duty Lids, Grates These shallow frames are suitable for use in thin or deep con- crete slo bs. All s izes of fra mes are reve rsible and ::an be insta ll e d with flange at base or top. Specify : 1. Catal og number. 2. To be insta lled w ith flange a t base o r top. Square Dimensions in inches Catalog Number A B c D Solid Lid Open Grate E F G Wt. Lbs . w/ w/ H lid grate 1 130 115 1 18 0 170 1 220 210 1 ~ 235 220 ¥. 265 300 ¥. 330 280 370 325 415 485 470 465 11 790 700 185 160 220 185 245 240 285 249 365 295 385 360 460 425 510 575 500 515 695 680 Wt. Lbs . w/ w/ H lid grate R-1879-A IL R-1879-A1 G 133.4 x 1334 1 'h 12 x 12 14 x 14 18 x 18 4 1 x 3 115 100 R-1879-A2L R-1879-A2G 18xl8 l'h 16x16 18 14 x18'·4 22x22 4 :Y.x4% :Y. 165 150 R-1879-A3l R-1879-A3G 20 x 20 l 'h 18 x 18 20 14 x 20 1 .• 24 x 24 4 :Y. x 5 :Y. 195 185 -R.-l-8_7_9--A-4-l--+-R--l-8-79--A-4-G--+-2-1_¥._•_x_2-1¥.-,~l-'h--+-20X"°2~0,,_-=-22=--x~2~2--1~2~6-x-2~6:-t--4-+-;'.-.-x-4--+--¥.-,~2-0-0-+-1-8 -5 R-1879-ASL R-1879-ASG 23Y2x23¥.z l'h 22 x 22 24 x 24 28 x 28 4 :Y.x6Jl2 * 235 255 R-1879-A6L R-1 879-A6G 25:Y.x25* l'h 24 x 24 26 x 26 30 x 30 4 l x5 :y. 245 2 15 R-1879-A7l R-1879-A7G 27 Jl2 x27Y2 'h 26 x 26 28 x 28 32 x 32 4 :Y.x7% :y. 290 260 R-1879-A8l R-1879-A8G 29Y.x29Y. l'h 28x 28 29 34 x 293 4 34 x 34 4 1Ysx5'/,. 1 340 390 R-1879-A9L R-1879-A9G 37*x31:Y. 1\-2 30 x 30 32 x 32 36 x 36 4 l x4 Y. :y. 360 310 R-1879-AlOL* R-1879-AlOG• 37x37 iv, 36x36 3n2x37 1.; 42x42 4 lx4 ?/a 1 485 445 Rectangular R-1879-Bll R-1 879-BlG 14 x 20 ~2 12 x 18 14 14 x 20 \, 18 x 24 4 :Y.x5 Y2 185 160 R-l 879-B2L R· l 879-B2G 13 'h x 25 'h \~ 12 x 24 13'" x 25>;; 18 x 30 4 :Y.x 4 Y2 16 5 180 R-1 879-B3l R-1879-B3G 19 'h x 25 'h 'h 18 x 24 19 3;" x 25 ~; 24 x 30 4 Ya x SY. 2 10 195 R-l 879-B4L R-l 879-B4G 19 1'2 x 3 l'h 'h 18 x 30 20 x 32 4 x 36 4 :Y.x 5 230 215 R-1879 -B5l R-1 879-BSG 19>;• x 3734 'h 18 x 36 20 x 38 24 x 42 4 1 Ysx5 295 310 R-1879-B6l R· l 879-86G 25'h x 31 'h 'h 24 x 30 25 34 x 31 34 30 x 36 4 l x 5 Ya :Y. 29 0 260 ~R-~1~8~7~9~-B~7~l--+-R--l-8-7~9--B~7~G--+2-5-l;'-,-x-3~7,-4-t-'h-+~2-4 _x_3~6'.""+--=-2~6-x~3~8-t3~0-x-4~2:-t-4,-t--1~x-~~-Yi~s-t-~¥.~•r335 295 R-1 879-B8l * R-l 879-B8G • 253;" x 49'4 'h 24 x 48 26 x 50 30 x 54 4 :Y. x 5 ~ 1 395 405 R-l 879-B9L • R-1 879-B9G • 3 l'A x 37'4 V2 30 x 36 :i2 x 38 36 x 42 4 1 x 6 \12 400 380 R-1879-BlOL* R-1879-BlOG* 3 l'h x 49'h •;, 30 x 48 3 rn x 49 3 .4 36 x 54 4 l x5 480 425 •Cover in two piece s. -·---..•a. I I~~ R-1 878-ASL Manhole Frame and So lid Lid • __j_ Hecrvy Duty R-1 878 s.ctions R-18 7 9·81 G Catch Basin Grate and Frame ! '-.--• .--·-----. Light Duty R-1879 Sections ...!. Figure Xll Development Permit City of College Station, Texas Site Legal Description : Lot 2 , Wolfpen Creek Subdivision Site Owner: Sonic Management Architect/ Engineer: Municipal Development Group Contractor: Advancing Designs Date Application Filed : January 25 , 1999 829 South Sam Houston Address : Huntsville , TX 77340 Telephone: (409)291-0338 Address : 2551-A Texas Ave So . Telephone No : (409)693-5359 P .O . Box 1133 Address : Navasota, TX 77868 Telephone No : ---------- Application is hereby made for the following development specific waterway alterations: Application Fee Signed Certifications Drainage and erosion control plan, with supporting Drainage Report two (2) copies each . Site and Construction Plans , with supporting Drainage Report two (2) copies each . Other: ------------------------------ ACKNOWLEDGMENTS : I, North B . Bardell, Jr. PE#60873 , design engineer/owner, hereby acknowledge or affirm that : T ~~~l s contained in the above plans and supporting documents comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design Standards. As a condition of approval of this permit application, l agree to construct the irnpro ·1ements proposed in this application according to these documents and the requirements of Chapter 13 of tn.@~::ulege Static ·ty Code . Contractor Figure XlI Continued CERTlFICA TIONS : (for proposed alterations within designated flood hazard areas .) A. I, certify that any nonresidential structure on or proposed to be on this site as part of this application is designated to prevent damage to the structure or its contents as a result of flooding from the l 00 year storm. Engineer Date B . C, certify that the finished floor elevation of the lowest floor , including any basement, of any residential structure, proposed as part of this application is at or above the base flood elevation established in the latest Federal Insurance Administration Flood Hazard Study and maps, as amended . Engineer Date C . (, North B. Bardell, Jr., PE #60874::ertify that the alterations or development covered by this permit shall not diminish the flood-carrying capacity of the waterway adjoining or crossing th is permitted site and that such alterations or development are consistent with requ irements of t he City of College Station City Code, Chapter 13 concerning encroachments of flood ways and of floodway fringes. CJkJts f}. ~ t, I Engineer Jan.22 , 1QQQ Date I, do certify that the proposed alterations do not raise the level of the l 00 year flood above elevation established in the latest Federal Insurance Administration Flood Hazard Study . Engineer Date Conditions or comments as part of approval • ------------------- [n accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities . I hereby grant this permit for development. All development shall be in accordance with the plans a nd specifications submitted to and approved by the City Engineer for the above named proj ect. All of the applicable codes and ordinances of the C ity of College Station shall apply . Figure Xll Development Permit City of College Station, Texas Site Legal Description : Lot 2, Wolfpen Creek Subdivision Site Owner: Sonic Management ------------- Architect/ . . . Municipal Development Group Engineer: -------------- C ontractor: Advancing Designs Date Application Filed : January 25 , 1999 329 South Sam Houston Address : Huntsville , TX 77340 Telephone: (409)291-0338 Address: 2551-A Texas Ave. So. Telephone No : (409)693-5359 P .O . Box 1133 Address : Navasota , TX 77868 Telephone No : ---------- Application is hereby made for the following development specific waterway alterations : ~ Application Fee ~ Signed Certifications 0 Drainage and erosion control plan , with supporting Drainage Report two (2) copies each . 0 Site and Construction Plans , with supporting Drainage Report two (2) copies each . 0 Other: ------------------------------ The information and conclusions contained in the above plans and supporting documents comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design Standards. As a condition of approval of this permit application , I agree to const ruc t the impro ·1 emen ts proposed in this application according to these documents and the requirements of Chapte r 13 of the College Station City Code . Property Owner( s) Contractor Figure XII Continued CERTCFICA TIONS : (for proposed alterations within designated flood hazard areas .) A. I, certify that any nonresidential structure on or proposed to be on this site as part of this application is designated to prevent damage to the structure or its contents as a result of flooding from the l 00 year storm. Engineer Date B . I, certify that the finished floor elevation of the lowest floor, including any basement, of any residential structure, proposed as part of this application is at or above the base flood elevation established in the latest Federal Insurance Administration Flood Hazard Study and maps, as amended . Engineer Date C. I, North B. Bardell, Jr., PE#60687~ertify that the alterations or development covered by this permit shall not diminish the flood-carrying capacity of the waterway adjoining or crossing this permitted site and that such alterations or development are consistent with requirements of the City of College Station City Code, Chapter 13 concerning encroachments of flood ways and of flood1SJ:~~f: Engineer Jan .22 , 1999 Date I, do certify that the proposed alterations do not raise the level of the l 00 year flood above elevation established in the latest Federal Insurance Administration Flood Hazard Study . Engineer Date Conditions or comments as part of approval ------------------- ln accordance with Chapter 13 of the Code of Ordinances of the City of College Station , measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. [ hereby grant this permit for development. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply .