HomeMy WebLinkAbout62 Development Permit 628 Collage Station Medical Center Cath LabMUNICIPAL DEVELOPMENT GROUP 2551 Texas Ave. South, Ste . A •College Station, Texas 77840 • 409-693-5359 •FAX: 409-693-42 43 • E-mail:mdgcs@gte.co m Co ns ultin g Engineers, S ur veyors, Planners and Env ironmenta l Co ns ultants December 3, 1998 Natalie Ruiz, Assistant Development Coordinator City of College Station Planning Division P .O. Box 9960 College Station, TX 77842 Re: New Cath Building Addition at College Station Medical Center Dear Ms. Ruiz: We hav e reviewed the engineering reports submitted by James C. Alvis, P .E., in November 1985 and February 1996 on the drainage calculations for the Co ll ege Station Medical Center. We have also reviewed the engineering report s ubmi tted by A.J. Ghaddar, P.E., in August 1986 on the Medical Office Building addition to the Co ll ege Station Me dical Center . Data from these reports and the addit ion al construction of3535 sq. feet of building in July of 1998 indicates an existing imp ervious area of 11.8612 acres currently controlled by detention faci liti es on this site. The proposed cath building addition w ill add 0 .0229 acres (1000 sq. feet) of impervious area to the site and will represent le ss than a 1% increase (0.0 019) to the overall impervious area . There is a stated overcapacity in the current detention facility and the additional runoff created by this proposed constructio n is w ithin that capacity as well as normal variations in choice of utilized coefficients in the rational formu la method of runoff calcu lations. Also it is noted that there are no flood plain zone indicated on the F.E.M.A.F.I.R.M . dated 1992. T here are no planned plumbing fixtures in the proposed building. Si ncerel y, ~-~~- North B . Bardell Jr., P.E. C.E.O. 000702-c. 02-41 (2989) DEVELOPMENT PERMIT PERMIT NO. 628 COLLEGE STATION MEDICAL CENTER -CATH LAB FOR AREAS OUTSIDE THE SPECIAL FLOOD HAZARD AREA RE: CHAPTER 13 OF THE COLLEGE STATION CITY CODE SITE LEGAL DESCRIPTION: TRACT A, BLOCK 3, BELMONT PLACE SECTION II OWNER: COLLEGE STATION MEDICAL CENTER 1604 ROCK PRAIRIE COLLEGE STATION, TEXAS 77840 409-7645185 DRAINAGE BASIN: LICK CREEK SITE ADDRESS: 1604 ROCK PRAIRIE TYPE OF DEVELOPMENT:This permit is valid for additional construction of a 1000 sq. ft. building. The Contractor shall take all necessacy precautions to prevent silt and debris from leaving the immediate construction site in accordance with the approved erosion control plan as well as the City of College Station Drainage Policy and Design Criteria. The Owner and/or Contractor shall assure that all disturbed areas are sodden and establishment of vegetation occurs prior to removal of any silt fencing or hay bales used for temporary erosion control. The Owner and/or Contractor shall also insure that any disturbed vegetation be returned to its original condition, placement and state. The Owner and/or Contractor shall be responsible for any damage to adjacent properties, city streets or infrastructure due to heavy machinery and/or equipment as well as erosion, siltation or sedimentation resulting from the permitted work. Any trees required to be protected by ordinance or as part of the landscape plan must be completely fenced before any operations of this permit can begin. In accordance with Chapter 13 of the Code of Ordinances of the City of College Station , measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. I hereby grant this permit for development of an area outside the special flood hazard area. All development shall be in cordance with the plans and specifications submitted to and approved by the City Engineer in the di velo men/ permit application for the above named project and all of the codes nd ordinances oft e ity o College Station that apply. \a-\S -?:\~ Date Date Date rl?e6C>f~~=€~:;-c-~t~-li~-~t -tF:~!1~:§r~-(n{L -:--::--::::-:-··:·-::--:--:-:-·-:-::········:······"··:·-···"'· ..... ···-·-·.··:·,:,,,:·:·:··m.wN-·-:··um.w.·-"·w_,,,_:,::-:·:-·-:--P-a---·e -:1] -----------v •------' -------- -----------·----------------- ------' -" ----. ------. -------------w-.-,--,,--.. , .. w •m-.-----,--------------------n-,-------------------.---w ·.·. w.---.... JL,_ ·.-. ·.• From: To: Date: Subject: Shirley Volk Deborah Grace 12/14/98 2:49PM Cath Lab at The Med -more info I have put a site plan and the development permit application and receipt in your office Oust now!) They REALLY need a permit to at least start the dirt work tomorrow! Surprise, huh?! Do we think we might be able to get that for them. This little addition is interior to the site, and actually within a curbed area. What else do they need to tum in to meet our requirements on this project? Also, I have the original of the engineer's drainage letter that I'm giving you with the above. CC: Jeff Tondre, Jessica Jimmerson, Lee Battle, Ver ... MUNICIPAL DEVELOPMENT GROUP 2551 Texas Ave. South, Ste . A •College Station , Texas 77840 • 409-693-5359 •FAX: 409-693-4243 •E-mail: mdgcs@gte.com Consulting Engineers, Survey ors, Planners and Environmental Co nsultants December 3 , 1998 Natalie Ruiz, Assi stant Development Coordinator City of College Station Planning Division P .O. Box 9960 College Station, TX 77842 Re: New Cath Building Addition at College Station Medical Center Dear Ms. Ruiz: We have reviewed the engineering reports submitted by James C . Alvis, P .E., in November 1985 and February 1996 on the drainage calculations for the College Station Medical Center. We have al s o reviewed the engineering report submitted by A.J. Ghaddar, P .E ., in August 1986 on the Medical Office Building addition to the Colleg e Station Medical Center. Data from these reports and the additional construction of 3535 sq . feet of building in Jul y of 1998 indicates an existing impervious area of 11.8612 acres currently controlled by detention facilities on this site. The proposed cath building addition will add 0.0229 acres (1000 sq. feet) of impervious area to the site and will represent less than a 1 % increase (0.0 019) to the overall impervious area. There is a stated overcapacity in the current detention facility and the additional runoff created by this proposed construction is within that capacity as well as normal variations in cho ic e of utilized coefficients in the rational formula method of runoff calculations. Also it is noted that there are no flood plain zone indicated on the F.E .M.A.F.I.R.M. dated 1992 . There are no planned plumbing fixtures in the proposed building. Sincerely, 1 Ywt/u i3 i3~tf J North B . Bard e ll Jr., P .E. C.E.O. 000702-c.02-41 (2989) MUNICIPAL DEVELOPMENT GROUP 2551 Texas Ave. South, Ste. A •College Station , Texas 77840 • 409-693-5359 •FAX: 409-693-4243 • E-mail:mdgcs@gte.com Consulting En g ineers, Survey ors, Planners and Environmental Consultants December 3 , 1998 Natalie Ruiz, Assistant Development Coordinator City of College Station Planning Division P.O . Box 9960 Colleg e Station , TX 77842 Re : New Cath Building Addition at College Station Medical Ce nter Dear M s . Ruiz: We have reviewed the engineering reports submitted by James C. Alvis , P .E., in November 1985 and February 1996 on the drainage calculations for the College Station Medical Center. We have also reviewed the engineering report submitted by A.J . Ghaddar, P .E., in August 1986 on the Medical Office Building addition to the College Station Medical Center. Data from these reports and the additional construction of 3535 sq . feet of building in July of 1998 indicates an existing impervious area of 11.8612 acres currently controlled by detention facilities on this site. The proposed cath building addition will add 0.0229 acres (1000 sq. feet) of impervious area to the site and will represent less than a 1 % increase (0.0019) to the overall impervious area . There is a stated overcapacity in the current detention facility and the additional runoff created by this proposed construction is within that capacity as well as normal variations in choice of utilized coefficients in the rational formula method of runoff calculations . Al so it is noted that there are no flood plain zone indicated on the F .E.M.A.F.I.R.M . dated 199 2. There are no planned plumbing fixtur es in the propo se d buildin g. Sincere ly, i)i.4u'f3,{3_,_hf! J N o rth B . Bardell Jr., P .E . C.E.O . 000702-c .02-41 (2989) MUNICIPAL DEVELOPMENT GROUP 2551 Texas Ave. South, Ste. A •College Station , Texas 77840 • 409-693-5359 •FAX: 409-693-4243 • E-mail:mdgcs@gte.com Consultin g En g ineers, Surveyors, Planners and Environmental Cons ultants December 3, 1998 Natalie Ruiz, Assistant Development Coordinator City of College Station Planning Division P.O. Box 9960 College Station , TX 77842 Re: New Cath Building Addition at College Station Medical Center Dear Ms. Ruiz: We have reviewed the engineering reports subm itted by James C. Alv is , P .E ., in November 1985 and February 1996 on the drainage calculations for the Co ll ege Station Medical Center. We have also reviewed the engineering report submitted by A.J. Ghaddar, P .E., in August 1986 on the Med ical Office Building addition to the College Station Medical Center. Data from these reports and the additional construction of 3535 sq . feet of building in July of 1998 indicates an existing impervious area of 11.8612 acres currently controlled by detention facilities on this site. The proposed cath building addition will add 0.0229 acres (1000 sq . feet) of impervious area to the site and will represent less than a 1 % increase (0.0019) to the overall impervious area. There is a stated overcapacity in the current detention faci lity and the additional runoff created by this proposed construction is within that capacity as well as normal variations in choice of utilized coefficients in the rationa l formu la method of runoff calculations. Also it is noted that there are no flood pl a in zone indicated on the F.E.M.A.F.I.R.M. dated 1992 . There are no planned plumbing fixture s in the proposed buildin g . Sincerely, , YlctdiiJB iJJ,ct;) North B . Bardell Jr., P .E. C.E.O. 000702-c.02-41 (2989) G :\COLUMBIA\CATHLAB\words\BA TILE .L TR information copies : file , hard copy to follow by mail : no Date : To : from: Subject: Copies: November 11, 1998 MR. LEE BATTLE Staff Planner City of College Station , Development Services Po Box 9960 College Station, Texas 77842 . Williamson Group Architects MED CENTER GATH LAB EXPANSION File , HARTMAN LEE : PLEASE FIND ATTACHED A COPY OF THE SITE PLAN AND FLOOR PLAN FOR THE GATH LAB EXPANSION. THIS IS THE PROJECT WE MET WITH YOU AND DISCUSSED ON 6 NOVEMBER, 1998. AS YOU RECALL WE DECIDED THAT THERE WAS NO NEED UNDER THE EXISTING CONDITIONAL USE PERMIT TO GO BEFORE P&Z WITH THIS MINOR ADDITION TO THE HOSPITAL. THANKS FOR YOUR HELP. LEON WILLIAMSON WILLL\MSON GROUP ARCHITECTS 106 East '26th Street, Bryan. Texas 77803 (v)409 .775.1778 (0409.775.1884 MUNICIPAL DEVELOPMENT GROUP 2551 Texas Ave. South , Ste. A •College Station , Texas 77 840 • 409-693-5359 •FAX: 409-693-4243 • E -m ail:mdgcs@gte.com Consultin g E ngineers, Sur veyors, Planners and Environm ental Consu ltants December 3, 1998 Natalie Ruiz, Assistant Development Coordinator City of College Station Planning Division P .O. Box 9960 College Station, TX 77842 Re: New Cath Building Addition at College Station Medical Center Dear Ms . Ruiz: We have reviewed the engineering reports submitted by James C. Alvis , P.E., in November 1985 and February 1996 on the drainage calculations for the College Station Medical Center. We have also reviewed the engineering report submitted by A.J. Ghaddar, P .E., in August 1986 on the Medical Office Building addition to the College Station Medical Center. Data from these reports and the additional construction of 3535 sq. feet of building in July of 1998 indicates an existing impervious area of 11.8612 acres currently controlled by detention facilities on this site. The propo sed cath building addition will add 0.0229 acres (1000 sq. feet) of impervio u s area to the site and will represent les s than a 1 % increase (0.0019) to the overall impervious area. There is a stated overcapacity in the current detention facility and the additional runoff created by this proposed construction is within that capacity as well as normal variations in choice of utilized coefficients in the rational formula method of runoff calculations. Also it is noted that there are no flood plain zo ne indicated on the F .E.M.A.F .I.R.M. dated 1992. There are no planned plumbing fixtures in the proposed building . Sincerely, r>/l,rJ)v'{},{l__y/ fl. North B. Bardell Jr., P.E . C.E.O . 000702-c.02-41 (2989) Dcvc:·:::n~:Iermit ;; ~ \J~ ~Q~ v~J 1,, City of College Station, Texas ~~ 0~) ~ TRACT A, IlIOCK 3, BEJ:M)N!' PIACE -SECTION ~ ~ v f \ \ 1604 ROCK PRAIRIE Site Legal Description : Site Owner: COLLEGE STATION MEDICAL CENTER Addres s : COLLEGE STATION, TEXAS 77845 Architect/ Engineer: __ WI_:_Ll.._I_AMS __ O_N_G_Ri_O_UP _____ _ Contractor: _B_R_I _TT_R_I_C_E_C_a.1P __ ANY ____ _ Date Application Filed : _1_2_1_1_4_1_9_8 ____ _ 1 Telephone: _7_6_4-_5_1_8_5 ________ _ 106 EAST 26th STREET Address : BRYAN, TEXAS Telephone No : _7_75'----1_7_7_8 _____ _ 3002D IDNGMIRE Address: COLLEGE STATION, TEXAS 77845 Telephone No : _6_93_-_4_0_7_6 _____ _ Approved : ___________ _ Application is hereby made for the following development specific waterway alterations : ADDITION OF A NE,W CARDIAC CATII LAB 24' WIDE x 43' IDNG TO TIIE EXISTING BUIWING. 0 Application Fee 0 Signed Certifications 0 Drainage and erosion control plan, with supporting Drainage Report two (2) copies each . 0 Site and Construction Plans, with supporting Drainage Report two (2) copies each . 0 Other: ------------------------------- ACKNOWLEDGMENTS: , ioJesigo fmgii;ieeFlowner, hereby acknowl e dge or affirm that: The information and conclusions contai.ned in the above plans and supporting documents comply with the current r e quirements of th e City of College Station, Texas City Code, Chapter 13 and its as sociated Drainage Policy and Design Standards . MUNICIPAL DEVELOPMENT GROUP 2551 Texas Ave. South, Ste . A •College Station, Texas 77840 • 409-693-5359 •FAX: 409-693-4243 •E-mail: mdgcs@gte.com Consu ltin g Engineers, Surveyors, Planners and Environmental Con sultants December 3, 1998 Natalie Ruiz, Assistant Development Coordinator City of College Station Planning Division P .O. Box 9960 College Station , TX 77842 Re: New Cath Building Addition at College Station Medical Center Dear Ms . Ruiz: We have reviewed the engineering reports submitted by James C . Alvis , P.E., in November 1985 and February 1996 on the drainage calculations for the College Station M e dical Center. We have also reviewed the engineering report submitted by A.J . Ghaddar, P.E., in August 1986 on the Medical Office Building addition to the College Station Medical Ce nter. Data from these reports and the additional construction of 3535 sq. feet of building in July of 1998 indicates an existing impervious area of 11.8612 acres currently controlled by detention faci li ties on this site. The proposed cath building addition will add 0.0229 acres (1000 sq. feet) of impervious area to the site and will represent less than a 1 % increase (0.0019) to the overall impervious area. There is a stated overcapacity in the current detention facility and the additional runoff created by this proposed construction is within that capacity as well as normal variations in choice of utilized coefficients in the rat ion a l formula method of runoff calculations. Also it is noted that there are no flood plain zone indicated on the F.E.~W~-f1ef\992 . There are no planned plumbing fixtures in the proposed buildiij~6t.nPL\Jl..1'\CE. Sincerely, D£.C l ~ \99S . /) Q "-l 1Y&4u'f31y-,-ht/ fl. co~~~~~EER\N~ 1 North B . Bardell Jr., P.E . }JY C.E.O . ,r-\., · 000702-c.02-41 (2989) 01 /01/1997 05:07 4097751884 03112 '98 lJ :OO FAX 409 693 4243 WILLGRP M D G MUNICIPAL DEVELOPMENT GROUP December 3, 1998 Natalie Ruiz, Assistant Development Coordinator City of College Station Planning Division P.O . .Box 9960 College Statioll, TX 77842 b: New Catti Building Addition at College Station Medical Center Dear Ms. :Ruiz: PAGE 02 ~00.2 We have reviewed the engineering reports submitted by J1U1es C. Alvis, P.E., in November 1985 and February 1996 on the drainage calculations fortbe College Station Medical Cemer. We have also reviewed the engineering report submitted by AJ. Ghaddar, P .E., in August 1986 on the Medical Office BuHdi.n~ addition to the College Station Medical Center. Dar.a from these reports and the additional construction of 3535 sq. feet of building in July of 1998 indicates an eximng impervious area of 11.8612 acres currently controlled by detentiOJl fa~ilities on this site. The proposed cath building addition will add 0.0229 acres (1000 sq. feet) of impervious area to the site and will represent less than a 1 % increase (0.0019) to the overall impervious area. There is a stated OV&Tcapaeity in the c;urrent detention facility a.nd th8 additiollal nmoff created by this proposed construction i.s within that capacity as well 1!.5 normal variations in choice of utilized coefficients in the rational formula method of runoff c:alcuJations. Also it is noted that there are no flood plain zone indicated on the F.E.M.A.F.T .R.M. dated J 992. There are no plauned plumbing fixtures in the proposed building. Sincerely, ~.-a..w_ 9--- North B. Bardell Jr., P.E. C.E.0. 000702-c.02-41 (2989) 01/01/1997 06:07 4097751884 WILLGRP PAG E 01 Post·it• Fax Note 7671 Date #of • psges G;ICOLUMSIA\CATHLABlwOf "9\CrTVCS .001 information copies: file , To/~ ,tS Co ,/Dept. hard copy to follow by mail : No Date: To: from : Subject: Copi~: LEE ; Phone# Fax# December 3 , 1998 Mr. Lee Battle, Staf, , •cu 11 •v• City of College Station 1101 Texas Avenue College Station, Texas 77842 Williamson Group Architects Cath Lab Expansion -College Station Medical Center File, HARTMAN From ~A.I £.,{,./ Co. Phone# Fax• IN A RECENT TELECOM, YOU MENTIONED THAT YOU NEEDED A DRAINAGE LETIER TO ACCOMPANY THE SITE PLAN IN YOUR FILES. PLEASE FIND ATTACHED A LEITER FROM M.D.G . CONCERNING THE DRAINAGE CALCULATIONS FOR THIS PROJECT. IF YOU REQUIRE FURTHER INFORMATION, OR JF THERE IS ANY OTHER ITEM FROM PLANNING'S PERSPECTIVE STANDING IN THE WAY OF A BUILDING PERMIT, PLEASE CALL. BEST REGARDS , LEON WILLIAMSON ~"" _, ~ ·,,,• -~··,·.I\ -}<"".::,..,. 'i: • •.., • ... :. ··..::..-,. ::',,,. '.' 1 ) ~ •• • ••-::. < ~· f ~. -~~ ' WILLIAM£0N GROUP ARCIDTECTS 106 Easl 26th Street. Bryan. Texas 77803 (v)409 .775.1778 (Q409 .'Z75 .1884