Loading...
HomeMy WebLinkAbout31 Development Permit 99-321 Campus Part Phase 2 1121 Welsh AveCAMPUS-PARK SUBDIVISION PHASE TWO PROBABLE COST ESTIMATE PA YING & SITE IMPROVEMENTS * 1 Excavation (6" depth) CY 914 $2.50 2 2" H.M.A.C. SY 1455 $6.00 3 6" Flexible Base SY 1750 $9.00 4 Lime Treatment (6" depth) SY 1750 $1.50 5 Reinforced Concrete Curb & Gutter LF 766 $8.00 6 4" Reinforced Concrete Sidewalk SF 1062 $3.00 7 Reinf. Concrete Handicap Ramp EA 5 $750.00 8 Sawcut, tie and repair at street EA 1 $750.00 ESTIMATED PAVING IMPROVEMENTS *Does not include paving for individual units DRAINAGE IMPROVEMENTS 'N"'~ ·' .. ·· · ., .. ·· ·. ·· · · :ft;Ee;""Rl 6 Y 1'-"N>. :: :'\(/ . • ' • J':t\1 .. N· ... •JT.0.• ... •.0.:.0.•.• .. '.•.:.:·_:.•.:.:_:.•.•.• V:"I . ~. ~~ J::::::f.::tw.: . ·:·:·:·:·:·:·:·:·:·:·:·:·: :::;:;:;:;:;:;:;:;:: ·. ·.·.·.·.·.·.·.-.=~--.· ::J:: 9 Silt Fencing (Erosion Control) WATER IMPROVEMENTS 10 6" P.V.C. SOR 3034 Water Line 11 Std. Fire Hydrant Assembly 12 6" M.J. Gate Valve & Box 13 6" M.J. Bend (11.25 degree) 14 6" M.J. Bend (22.5 degree) 15 6" M.J. Bend (90 degree) 16 Cement Stabilized Embedment SEWER IMPROVEMENTS 17 4" Service Taps To Existing 6" 18 6" PVC Sewer Pipe (6'-8' depth) 19 Cement Stabilized Embedment 20 Tie to Existing Manhole 21 4" Service Taps 22 Standard Cleanout c: \CostPhase2.xls LF 330 $1.25 ESTIMATED DRAINAGE IMPROVEMENTS LF 810 $20.00 EA 1 $2,000.00 EA 9 $800.00 EA 1 $250.00 EA 2 $250.00 EA 1 $250.00 LF 500 $10.00 ESTIMATED WATER IMPROVEMENTS EA 12 $300.00 LF 95 $35.00 LF 600 $10.00 EA 1 $500.00 LF 460 $28.00 EA 1 $200.00 ESTfMATED SEWER IMPROVEMENTS 1of2 $2,285.00 $8,730.00 $15,750.00 $2,625.00 $6,128.00 $3,186.00 $3,750.00 $750.00 $43,204.00 $412.50 $412.50 $16,200.00 $2,000.00 $7,200.00 $250.00 $500.00 $250.00 $5,000.00 $31,400.00 $3,600.00 $3,325.00 $6,000.00 $500.00 $12,880.00 $200.00 $26,505.00 . l..' .; J• . •( •' 't; ..... ~ . l "· f A ; , '• l'J .: ' .... ' .... " I l' i 1~ .. ! . •' .. ~ .. .. .. • ' -I !.. i • ·" . ,. . ' . ,, 1-'l : l ESTIMATED PROJECT COST Contigency (153) TOTAL PROJECT COST NOTES CONCERNING OPINIONS OF PROBABLE CONSTRUCTION COST $101,521.50 $15,228.23 $116,749.73 Urban Design Group's (UDG) opinions of probable construction cost provided for herein are made on the basis of our experience & qualifications and represent our best judgment as an experienced and qualified professional engineering firm generally familiar with the construction industry and applicable development regulations. However, since UOG has not obtained approval from the appropriate jurisdiction and UDG has no control over the cost of labor, materials, equipment or services furnished by others, or over the Contractor's methods of determining prices, or over competitive bidding or market conditions, UDG cannot and does not guarantee that proposals, bids or actual construction cost will not vary from opinions of probable construction cost prepared by UOG. I?. /&.. '74 c:\CostPhase2.xls 2 of 2 ,, ' l •. , ... ·"' .. ' • I .; \/ .. " J' DEVELOPMENT PERMIT PERMIT NO. 99-500321 Campus Park Phase 2 FOR AREAS OUTSID E THE SPECIAL FLOOD HAZARD AREA RE : CHAPTER 13 OF THE COLLEGE STATION CITY CODE SITE LEGAL DESCRIPTION: Holleman & Welsh DATE OF ISSUE: 1/19/2000 OWNER: Blake Cathey 6345 Smith Road Bellville , Texas 77418 409-218-1200 TYPE OF DEVELOPMENT: SPECIAL CONDITIONS: F ull Permi t No n e SITE ADDRESS: 1111 Welsh DRAINAGE BASIN: Bee Creek Trib B VALID FOR 12 MONTHS CONTRACTOR: The Contractor shall take all necessary precautions to prevent silt and debris from leaving the immediate construction site in accordance with the approved erosion control plan as well as the City of College Station Drainage Policy and Design Criteria. The Owner and/or Contractor shall assure that all disturbed areas are sodden and establishment of vegetation occurs prior to removal of any silt fencing or hay bales used fo r temporary erosion control. The Owner and/or Contractor shall also in sure that any disturbed vegetation be returned to its origina l condition , placement and state. The Owner and/or Contractor shall be responsible for any damage to adjacent properties, city streets or infrastructure due to heavy machinery and/or equipment as well as erosion , siltation or sedimentation resulting from the permitted work. Any trees required to be protected by ordinance or as part of the landscape plan must be completely fenced before any operations of this permit can begin. In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existin g drainage facilities . I hereby grant this permit for development of an area O UTSID E the special flood hazard area . All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer in the development permit application for the above named project and all of the codes and ordinances of the City of College Station that apply. 1-r1-zorr Date I -2-Z.. -UdO Date Contractor Date FOR OFFICE ugo y CAS E NO .: ~ DATE SUBMITTED : 1,J l<o'J'1 "1 FINAL PLAT APPLICATION (check one) ./ Final --__ Replat __ Vacating Minor __ Amending The following items must be submitted by an established filing deadline date for P & Z Commissions consideration. MINIMUM SUBMITTAL REQUIREMENI'S _./_Filing Fee of$200.00 _./_Development Permit Application Fee of$100.00 (if applicable) (submitted previously) _./_Infrastructure Inspection Fee of$300.00 (if any public infrastructure is being constructed.) _ ./ _ Application completed in full . _./_Thirteen (13) folded copies of plat. (A signed mylar original must be submitted after staff review.) _./_One (1) copy of the approved Preliminary Plat and/or one (1) Master Plan (if applicable). _ ./ _ A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. _./_Two (2) copies of public infrastructure plans associated with this plat (if applicable). APPLICATION DATA NAME OF SUBDIVISION Campus Park Subdivision Phase 2 SPECIFIED LOCATION OF PROPOSED SUBDIVISION near southeast corner of Holleman and Welsh ADDRESS not ava ilable LEGAL DESCRIPTION 4 .102 acres of the Holleman Addition Volume 778 Page 173 APPLICANT/PROJECT MANAGER'S INFORMATI ON (Primary Contact for the Project): Name Blake Cathey Street Address 6345 Smith Road City College Station State T exas Zip Code 77418 E-Mail Address bcathey@flash.net Phone Number ( 409) 870-5031 Fax Number NI A PROPERTY OWNER'S INFORMATION: Name same as above Street Address __________________ City ___________ _ Stat e Zip Code ______ E-Mail Address------------ Phone Number Fax Number -------------- ARCHITECT OR ENGINEER'S INFORMATION: N am e Urban Design Group Street Address 909 Southwest Parkway East, Suite E City College Station State Texas Phone Number FIN AL PLAT APPLI CATI ON FNLPAPP .DOC 3125 /99 Zip Code (409) 696-9653 77840 Fax Number E-Mail Address udgcs@ txcyber .com (409) 6 96-9752 I of2 SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION Application is hereby ma~ for the fol~wing development specific site/waterway alte~ons : CrJm:fµ!4 ~;JtM/c t-JA_. J--1111 N.!M ~ I, ft /If, , design engineer/owner, hereby acknowledge or affirm that: ACKN~~N~: ~ The i'nnation and conclusions contamed in the above plans and supporting documents comply with the current requirements of the City of College Station. Texas City Code, Chapter 13 and its associated Drainage Policy and Design Standards. As a condition of approval of this permit application. I agree to construct the improvements proposed in this application according to these documents and the requirements of Chapter 13 of the College Station City Code. Property Owner(s) Contractor CERTIFICATIONS: (for proposed alterations within designated flood haz.ard areas.) A. I, certify that any nonresidential structure on or proposed to be on this site as part of this application is designated to prevent damage to the structure or its contents as a result of flooding from the 100 year storm. Engineer Date B. I, certify that the finished floor elevation of the lowest floor, including any basement, of any residential structure, proposed as part of this application is at or above the base flood elevation established in the latest Federal Insurance Administration Flood Hazard Study and maps, as amended. Engineer Date C. I, certify that the alterations or development covered by this permit shall not diminish the flood-carrying capacity of the waterway adjoining or crossing this permitted site and that such alterations or development are consistent with requirements of the City of College Station City Code, Chapter 13 concerning encroachments of floodways and of tloodway fringes. Engineer Date D. I, do certify that the proposed alterations do not raise the level of the 100 year flood above elevation established in the latest Federal Insurance Administration Flood Hazard Study. Engineer Date Conditions or comments as part of approval:---------------------------- In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion. and sedimentation shall not be deposited in city streets, or existing drainage facilities . All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. FINAL PLAT APPLICATION 3 of3 Public Water Infrastructure ~utility layout sheet -showing casements (plaUcd or by separate instrument) O If separate instrument casements arc nccdcd -do not approve until we get them recorded 0 TXDOT-pcrmits nccdcd? ft Scaled and Signed ~ 0 0 Eogi~ Esrjmatcs Lines Mpe material 7 Pipe sizes (allowabJc. ••• 6,8,12,16,18 -note DO 10" approved) · 0 Depth (4'+)(min.max) · 0 Separation distaru:cs (TNRCC) Y All utilities in plan cl profile w/siv;s and type a Privale VI. Public line distinction 0 Wycs not past property line (so meter can be within ROW/casement) a Max # of connections for me waterline (TNRCC) 0 Pipe ddlcction (noted as Y .. degrees. radius -with begin/end curve, not atjl) ~Grades -existing and proposed (centerline. right and left) shown in profile 0 Full TNRCC compliance fi: Conflicts with other utilities shown ~ Labels on all major items in plan & profile (crossings) 0 Siu/Location sufficient for overall City nccds/mastcrplan ~ ~:m=~=W µ~ ~ }Jf2," Stationing on all~ and taps l!~vc spacing csoo') J.Jv a Val~ -system isolation 0 Valves -at hydrant 0 Bacldlow prcvcntcrs/ and chock valves uses as ocoessary (@irrigation/fire sprinldcr/poolslha:zards) 0 Blowoffs (FH ok too) @ end of dead cod lines a Air rdcasc valves at all major high points FiceHydrants -( /l\Pf ~e,.c,f,e_.,,J O Fuc hydnnt spacing (Ccwcrage) 'f ~ -I F°U'C hydnnt localion (rclativc to curb) U'C hydant-ddail/typc specified a F°U'C flow calculations provided Service Lines a Service lines -materials and me specified from main to meter 0 Services provided to all lots to a point beyond sidewalks on both sides of &trcct I a{l2 "· Project Name: _________ _ Review Date: __________ _ Reviewer: ___________ _ Public Water Infrastructure< cont.) Detan1 0 Standard Details noted or included (rcfcrcoccd as city of CS Standard Details) 0 Details for all non-standard items (includcd/ok) (not on CS Std. detail sbcct) a All MI valves and fittings a Thrust blocking 0 EucDl('»t width adequate 0 Embc:chnc:nt details (specify option) O Trench safety if dccpel' than 5' D Erosion control notes The following items arc variaDccs to the College Station public waterline standards: 2aC12 "· Project Name:. _________ _ Review Date: __________ _ Reviewer:. ___________ _ Public Wastewater Infrastructure General )i' Overall utility layout 5bc:ct -showing casements (platted or by separate instrument) O If separate instrument casements ~ needed -do not approve until we get them recorded 0 TXDOT permits~? ;f Scaled and Signed J 0 0 Enginccrs Estimates Lines R Pipe material p Pipe sizes (allowablc. .•. 6,8,10.12.lS.18} 0 Depth (min COYCC) D Depth ( c:xccssivc) 0 Separation distances (TNRCC) __ii/ All utilities in plan &:. profile w/ma and type D Private vs. Public line distinction 0 Wycs not past property line fi' Grades-existing and proJ>C*d (centerline, right and left} shown in profile 0 Flowlines (spccificd/labelcd) 0 Full TNRCC complianoc 0 Conflicts with other utilities shown (min. I 'clear I except water-sec TNRCC) 0 Labels on all major items in plan & profile (crossings) 0 Size/Location sufficient for overall City necds/mastcrplan 0 Lines located in PUFJROW ,ff Stationing on all manholes and &CIViccs Manbolq 0 Lines cod in MH 0 Manhole spacing (max SOO') 0 Manhole diameter based on depth and line size (4 •vss diam.) D M.anholc covers -"'watertight" cover if in floodplain 0 Manholes acceWblc from public ROW/casement 0 Manholes at change of alignment. grade or size 0 Drops through manhole (TNRCC) ScmccLincs D Service lines -materials and sizc specified from main to cod D Services provided to all lots to a point beyond sidewalks on both sides 0 Services~ 6" enter at manholes 3al12 "· Project Name: _________ _ Review Date:. __________ _ Reviewer: ___________ ~ Public Wastewater Infrastructure< cont.) ~ 0 Standard Details noted or included (rcf'crcnccd as city of CS Standard Details) 0 Details for all non-standard it.ems (mclude/ok) (not on CS Std. detail sheet) 0 F.ascmcot width adequate 0 Embcd1J1C11t details (specify Option) 0 Trench safety if dccpcr than S' D Erosion control notes The following items arc variances to the College Station public wastewater standards: "ol12 Project Name: _________ _ Review Date:. _________ _ Reviewer: __________ ~ Public/Private Streets ~ ft/ Overall plan layout of streets ft Plan and profile for all streets O If scparmc iDsUumcDt casements an: nccdcd -do not approve until we get them rcc:ordcd D TXDOT permits nccdcd? ft Scaled and Sig:ncci · /Jo D Enginccrs Estimates Street Paving Plan jf Sidewalk locations per subdivision regs. D Curb inlets shown D Culverts location D Storm Sewer location D ~:!=p~t f~~eJe-d . ~ Rightofway/cascmentwidth J.}p-f l~k/e-1 ~'-_} < 1 _ ~"Radius sizes for (curb returns, mCdian noses. turn lanes, etc) ~T ~ D Cwb and Gutter delineated D Street Names ~ Plan and Profile -stationed • / / J ~ Benchmarks rcfcrcnccd #oi '-5~ O Ccntcrlinc stationing info. (PC, PI, PT, othct angl~ pf) / /J fl / I C D Curvcinfo(lcngth.tangcot.radius.anglc) #.o 1rl-io tHt <9&~ -J:.9T' 0v '(fe__,-~ 0 Min. and Max. grades 0 Radii '~ ~~~ D Location D X-slopc D X«Ction (bcddin& thi~ stccl) -sec details 'ji Handicap ramps (location, x-slopc, long slope, landing width, sideslopcs, no Cwb returns on ramps) Paving Profile D All proposed and existing utility conflicts shown with size and 1lowlinc D Profile of existing ground (ccntcrliDc. right and left) 0 Location of propo&cd storm SCWCl'I with size and grade O Top of curb profile with grades 0 Proposed paving profile 'o{J2 { Public/Private Streets(cont.) Details 0 Sidewalk x«Ction a Tic bctwccn sidewalk and back of aub ( if applicable) 0 Paving x-scction w/crown dimensioned 0 Handicap ramps 0 Cwb and gutta Project Name:, _________ _ Review Date: _________ _ Reviewer: ___________ ~ The following items arc variances to the College Station 5lrCCt standards: 6al'l2