Loading...
HomeMy WebLinkAbout19 Development Permit 99-296 Carter Creek Relocationi)£'VE LOPMEN'I' SER-.-V1CL :=; TRANSMITTAL LETTER qQ--51)2_g'(o Name/Firm : ~f2;?....-. lVle1<ALf (Mt::>9-} Address : '2.55\ JE.Mb ANE. Sm:rrµ. Ste... A l ( 01-1-S(#i. Vv:n ttlt-1, ly__ 17 BY o Date: ce I ZD)9 9 Phone: (d1 'b-5~5 °' Fax: Co'J':?-<dZY'; We are transm itting the following for Development Services to review and comment: (Check all that apply .): 0 Master Development Plan 0 Preliminary Plat w/ 0 Redlines ~eve !opment Permit App . w/ 0 Redlines 0 Conditional Use Permit 0 Final Plat w/ 0 Redlines 0 Rezoning Application 0 FEi\iA.. CLOr-.WCLOMR/LOMAILOMR 0 Site Plan wl 0 Redlin es 0 Variance Request w/ 0 Redlines ar0ther -Please specify 0 Gradi ng Plan 0 Landscape Plan 0 Irrigation Plan w/ 0 Redlines ~C..VJfY'A11~ Srr£. w/ 0 Redlines 'PL.AN w/ 0 Redlines m ~@~!f-==D=--rfl-[fw-- 0 Buiiding Construction Documents w/ D Redlines r n AUG 1 9 1999 U1 INFR~STRUCTURE AND ENGINEERING DOCUMENTS By ll:E:__ IO All infrastructure documents must be submitted as a complete set. ~ The following are included in the complete set : 0 Waterlin e Construction Documents w/ 0 Redlines 0 Sewerline Construction Documents w/O Redlines 0 Drainage Construction Documents w/ 0 Redlines 0 Street Construction Documents w/ 0 Redlines 0 yasement application with metes & bounds decsription IB" Drainage Lener or Report w/ 0 Redlines D Fire Flow Analysis w/ 0 Redlines Special Ins tructi ons : .::f !::-FF-I ~~s - k.zzexo 0 TxDOT Driveway Permit ef ,)XDOT Utility Permit ~ Other -Please specify Eu~..c..1ie.tiN\c -C~H:i. 'fOL fu l.)0'-1' I vz..-, Ms ¥'...Nti\..~ He~ @[\)'-f CoftES ri~ --n-)£ fF~Mn ) ft.:fb-e.-c ~ .fl,:Ns \...) I c1..\... TRANS~.!~ ;.l. LElTSil TRA"S~.:~.::>OC 03 _3 .99 I of I .. ...!" . . . -·--· ----FOR omcr u E o:· .L.¥. CASI NO.: Cj 4•1r:· ~W -DA TE SUBMTITED:--;.o;-rr.;;:--:;;~ COLUGI. STAllON DEVEL OPMENT P ERMIT MINTh1UM SUBMITTAL REQUIREMENTS --..l-s100 .oo Development Permit Application Fee. __ v Drainage and erosion control plan, with supporting Drainage Report two (2) copies each. J:!iA_ Notice oflntent (N.O .I.) if disturbed area is greater than 5 acres. . a_ 10 5 5 +-{ 30 LEGAL DESCRIPTION Aff'lc'f-_ ?7.S Act.P> ltco rH:-1 TJ}'?I C:Jr-s.µ. (o ~ s . µ . ~o APPLICANT (P . c-Cr--1..-ru...fi th~r._t;p;\·'0 ~) ) ~'t:::(S"C\N~ NC::.-.f'~ . .l\J"4"'1'E.-A1,..1..t..k 6€.\~\MP S!+-M 1$ runary ontact or e roJect : Name -r.fL\'?..E. j>.c,'\.J\2 (~oz...\J l~ ""INc..) -~~~~~~~-~~~-~--------------------~ Str~t Address "4 002... P\s('f-".N State ~-Y~x __ _ Zip Code 17 80 I E-Mail Address ------------- Phone Number 777 -"20~ ~ Fax Number ________________ _ PROPERTY OWNER'S INFORMATION: Name H ~ ??a ?A~~~DLS\-1\f' Street Address L.Jc::;1a o (A-e..-qp,<. Ce.E..Elf, ~~'i City --~-~'i_A-N ________ _ State f)C Zip Code l78o3 E-Mail Address------------- Phone Number Z.Cc>o -I\ I) Fax Number------------------ ARCIDTECT OR ENG~EER'S INFOR.iYfA TION : Name t'..A'fA>N fV\t,--icA-Li:= {M 1J~1ufAL Pe.I~ffv'\CN.1 ~ti\j'f' J . Street Address z s5 l l'E-~ Ave . $. ~ . A City CoLt.C/;;;tE. $-rAI ~ State \'5l Zip Code 77-0t..\c E-Mail Address Md5cs ~ %-tl.f\.e.1: Phone N umber Co <=t 3-5~ Sq Fax Number ___ Cd~A_.S"----Li .... Z ...... Y--'--='>"---------- Application is hereby made for the following development specific site/waten.vay alterations : ACKJ".'O\VLEDG!\:1ENTS : I , Nc LT li f:o. itst.Of.LL )Je. , design engineer.tew~er., hereby acknowledge or affirm that: The information and conclusions cont.3.inc d in the above plans and supporting documents comply \vith the current requirements of the C ity of College St::i.t io n, Texas City Code, Chapter 13 and its assoc iated Drainage Policy and Design S t.3.nchrds . As a c ondition of a pproval of thi s pem1it applic:ition, I agree to c onstruct the improvements proposed i..-1 this application according to these doc uments and the requi rements of Chapter 13 of the College Station Ci ty Code. DE V"ELO?.'.!~:"-"T PER.\!IT DPER.\:IT .DOC 3!24199 Contracto r 1 of :! CERTIFICATIONS: (for proposed alterations within designated flood hazard areas .) A. I, t\.iU'!l-\ 0«~6l.L. 7e. , certify that any nonresidential structure on or proposed to be on this site as part of this application is designated to prevent damage to the structure or its contents as a result of flooding from the 100 year storm . Engineer Date B. L ~tkt, 1~ £,, ~,)...L J' e.. , certify that the finished floor elevation of the lowest floor, including any basement, of any residential structure, proposed as part of this application is at or above the base flood elevation established in the latest Federal Insurance Administration Flood Hazard Study and maps, as amended. Engineer Date C . L No'L 1 \i 'f>, ~u... 7(... , certify that the alterations or development covered by this permit shall not diminish the flood-carrying capacity of the waterway adjoining or crossing this permitted site and that such alterations or development are consistent v..ith requirements of the City of College Station City Code, Chapter 13 concerning encroachments of floodways and of floodway fringes. Engineer Date D . I, ND'!-1 _~ 6, ~~~LtlJf.. , do certify that the prop~s_ed al:erations do not raise the level of the 100 year flood above elevation established m e latest Federal Insurance Administration Flood Hazard Study. Engineer Date Conditions or comments as part of approval:--------------------------- In accordance \\.ith Chapter 13 of the Code of Ordinances of the City of College Station., measures shall be taken to insure- that debris from construct ion, erosion, and sedimentation shall not be deposited in city streets , or existing drainage facilities . All de velopment shall be in accordance with the plans and specifications submined to and approved by the City Engineer for the abo ve named project. All of the applicable codes and ordinances of the City of College St.:u io n shall apply . DEVELOP .'.!E:--1 PER..\!!T DPE R.1.::-:-.ooc 3124 ;99 2 of2 Project Name: __________ _ Review Date: __________ _ Reviewer. -----------~ Public/Private Storm Sewer General &/ Overall plan layout of drainage facilities (can be shown on street plan) showing easements NIP.. J8:/If separate instrument easements are needed -do not approve until we get them recorded 8' Plan and profile for all storm sewers VTXDOT permits needed? ~Sealed and Signed rn/' Engineers Estimates Storm Sewer/Culvert! 0 Pipe material (RCP = storm, RCPorCMP = culvert) 0 Pipe sizes labeled (see pg.47 DPDS) 0 Size/Location sufficient for overall City needs/masterplan 0 Depth (min cover) 0 Depth (e.xcessive) 0 All utilities in plan & profile w/sizes and type 0 Private vs. Public line distinction 0 Street grades -existing and proposed (centerline, right and left) shown in profile 0 Flowlines (specified/labeled) 0 Conflicts 'With other utilities shown 0 Labels on all major items in plan & profile 0 Located ,.,;thin drainage easement or right-of--way (specify width) (public only) 0 Easement 'Width adequate per DEDS 0 Stationing shown 0 Outfall location (if open, is rip-rap needed per design calcs) 0 Does it match drainage report (sizes, inlets, etc) 0 Hydraulic Grade Line (on plan or in drainage report) NIA. 0 0 0 CJ 0 0 N /A 0 0 0 0 0 0 0 Junction Bo:x~anboles!Inlet! Lines end in JB/MH JB/Manhole spacing (see pg 47 DPDS) JB/Manholes accessible from public ROW/easement JB/Manholes at change of alignment, grade or size Drops through inlet/manhole.IJB (see pg 48 DPDS) Curb inlets shown and labeled (referenced to drainage report) Detail5 Standard Details noted or included (referenced as city of CS Standard Details) Details for all non-standard items (included/ok) (not on CS Std. detail sheet) Embedment details (specify option) Trench safety if deeper than 5' Erosion control notes Cul verts (SET) Inle t/J-Box or manhole details (manhole access) 7 of12 Project Name: __________ _ Review Date: __________ _ Reviewer: ____________ _ Public/Private Stonn Sewer (cont.) Cha:Dneh ~./.Cross sections ..,.,;th side slopes -meets DPDS 12" .Channel Liner -per DPDS Q/fangirudinal slope (0.4% min.) ~ Rip Rap needed ? ,.,..Qetails ~ Standard Details noted or included (referenced as city of CS Standard Details) ~Details for all non-standard items (include/ck) (not on CS Std. detail sheet) ~E ros i on control notes Detention Svstem 0 Side slopes 0 Bouom slopes 0 Gradingplan 0 Low flow flume 0 Outlet Strucrure sho"'n -corresponds to drainage report 0 Inlet Strucrure sho-.n -COIT"...sponds to drainage report 0 Emergency spillv.-ay -corresponds to drainage report 0 Rip Rap if high vel ocities exist at inlet or outlet -length/width/size/details 0 F1owlines at inlet and outlet 0 Complies with drainage report t-J/A 0 0 0 0 0 Detail5 Standard Details noted or included (referenced as city of CS Standard Details) Details for all non-standard items (included/ok) (not on CS Std. detail sheet) Erosion control notes Inlet structure Outlet structure The following items are variances to the College Station drain.age standards: 8of12 N/A Drainage Reports Looation ~ Primary drain.age system identified ~-:,Surrounding developments shown ~ Local streets, drainage systems shown Description tr _,,Acreage of project l~Y) .. and cover described (9-"" yrimaryisecondary systems within property shown ~ General description Drainage Basins Project Name: __________ _ Review Date: __________ _ Reviewer: ____________ _ l? References to FIRMs if applicable ~.,Secondary system flow patterns and impact of development on existing system ~Proposed pathways to Primary system sho-wn or descnbed Design Criteria 'g_ fay deviation from standards being requested? g/ ,))is..'"USSion of site constraints and capacities (streets, existing structures, etc.) ¥" Dis..-ussion of any applicable previous drainage studies and how this-plan will affect it Hvdrologic Criteria 9""' Rainfal.IJrunoff calcularion method descnbed and calculations provided S/ faetemion Eiisdwge I storage calculation method I calculations ~ Storm recurrence intervals used ~ Dis..-us.s:ion of other drainage facility design criteria used if not referenced in Standards Hvdaulic Criteria Er Identify capacity of systems used ~Specify velocities at critical points in system ;a Identify detention I retention outlet and routing ~Discussion of other drainage facility design criteria used not referenced in Standards Drainage Facilitv D~ign ~ Discuss drainage patterns I flows (pre YS . post) ,..S (A 'El:. Are they draining water onto another property owner? -if so, is it where the water flowed before? and is it not .,.)DOre than what flowed there before? and no faster than it flowed before? • . ff" Discuss erosion control measures employed N/ Ji. ';8! Dis..'"USS detention pond design (sideslope, low flow channels, outlet works, :freeboard, emergency spillway) rN/ A )( Discuss maintenance access and responsibilities Con.clu sion s ta" Yerify compliance with DPDS (signed and sealed certification) ~E xplain effectiveness of improvements with regard to controlling discharges of 5 -100 year storm by a) Detaining b) Accommodating runoff in existing I proposed easements or ROW discharging into primary system c) Combination of a & b 9 ofl2 • Project Name: _________ _ &:view Date: ---------~ &:viewer: ----------~ Drainage Reports( cont.) ~peodices ~ y.eferences (all criteria and technical information~ &"' Hyd.!yl-0 gic computations (¥"' Land use assumptions for adjacent property ~Minor/major sterm runoff a! specific points CYJ ric/fully developed runoff specific points dro graphs a! critical points . computations ~Culvert capacities (headwater and tailwater asrumptions) iJ/b. ~ Storm sewer capacities tJ/Pt, ';g: Street capacities ,a._,~torm inlet capacities (inlet control rating) S----Open channel design N/A '& Detention area I volume capacity I outlet capacity Attached Drawings 6" Location map with drainage patterns m/ J1oodplain map if any ~Drainage plan with topo (existing and proposed with arrows if needed) ~Details of outlet structures - 10 of!'. ·-. Project Name: __________ _ Review Date: ----------- Reviewer. ___________ ~ DEVELOPMENT PERMIT L Application Fee (SlOO) 2 . Application 3 . Erosion Control Plan 4 . EPA/NOI (> 5 acres) 5 . Public Infrastructure Inspection Fee (S300) 6 . Drainage Report 7 . HOA Covenants for maintenance of detention/retention ponds 8 . Easements Dedicated (separate instrument) 9 . TXDOT permits issued 10 . Engineer's Estimates (1-4 necessary for rough gradin~clearing ....... all others necessary for full permit) o :10.:VC _ sa"lonm"=ogr'Gbkllt.doc 3f2 5199 11of12 Project Name:. __________ _ Review Date: ----------~ Reviewer: ------------- TXDOT PERMIT CHECKLIST 0 ermit signed (Utility or Driveway) by o'l'r'Iler ~Set or excerpts of construction plans of what is proposed within ROW ~ ;Iraffic Control Plan (TMUfCD) V Drainage Calculations (if applicable) ForCityU~. . ov ,,Sign penillts o/' _,.Attach cover letter t>/ Submit in triplicate to TxDOT 12 of1 2