HomeMy WebLinkAbout18 DP Liberty 05-38CITY OF COLLEGE STATION
Plann ing & Development &rvica
SITE LEGAL DESCRIPTION:
Liberty Subdivision
Lot 2B and Lot 2C
DATE OF ISSUE: 08/05/05
OWNER:
Salim Ismail
1203 University Srive
Colleg Station , Texas 77845
TYPE OF DEVELOPMENT:
SPECIAL CONDITIONS:
DEVELOPMENT PERMIT
PERMIT NO. 05-38
FOR AREAS OUTSIDE THE SPECIAL FLOOD HAZARD AREA
RE: CHAPTER 13 OF THE COLLEGE STATION CITY CODE
SITE ADDRESS:
2500 Earl Rudder Freeway S
DRAINAGE BASIN:
Wolf Pen Creek
VALID FOR 9 MONTHS
CONTRACTOR:
Full Development Permit
All construction must be in compliance with the approved construction plans
All trees required to be protected as part of the landscape plan must be completely barricaded in accordance with Section
7.5.E., Landscape/Streetscape Plan Requirements of the City's Unified Development Ordinance, prior to any operations of
this permit. The cleaning of equipment or materials within the drip line of any tree or group of trees that are protected and
required to remain is strictly prohibited. The disposal of any waste material such as, but not limited to, paint, oil, solvents,
asphalt, concrete, mortar, or other harmful liquids or materials within the drip line of any tree required to remain is also
prohibited .
****TCEQ PHASE II RUELS IN EFFECT****
The Contractor shall take all necessary precautions to prevent silt and debris from leaving the immediate construction site
in accordance with the approved erosion control plan as well as the City of College Station Drainage Policy and Design
Criteria. If it is determined the prescribed erosion control measures are ineffective to retain all sediment onsite, it is the
contractors responsibility to implement measures that will meet City, State and Federal requirements . The Owner and/or
Contractor shall assure that all disturbed areas are sodden and establishment of vegetation occurs prior to removal of any
silt fencing or hay bales used for temporary erosion control. 'The Owner and/or Contractor shall also insure that any
disturbed vegetation be returned to its original condition , placement and state . The Owner and/or Contractor shall be
responsible for any damage to adjacent properties, city streets or infrastructure due to heavy machinery and/or equipment
as well as erosion, siltation or sedimentation resulting from the permitted work.
In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure
that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage
facil iti es .
I hereby grant this permit for development of an area outside the special flood hazard area . All development shall be in
accordance with the plans and specifications submitted to and approved by the City Engineer in the development permit
application for the above named project and all of the codes and ordinances of the City of College Station that apply.
Date
r:s ---r o ,.. o r
Date
'
Date Submitted
CITY OF COL LEGE STATION
D
D
Pl1111 ning r7 Dfl velopm ent SertJitet
DEVELOPMENT PERMIT
MINIMUM SUBMITTAL REQUIREMENTS
$200 development perm it fee.
$600 .00 Public Infrastructure Inspection Fee if applicable. (This fee is payable if construct ion of a public
waterline , sewerline , sidewalk, street or drainage facilities is involved .)
Drainage and erosion control plan , with supporting Drainage Report two (2) copies each
Notice of Intent (N .0.1.) if disturbed area is greater than 5 acres
Date of *Required Preapplication Conference: __________________ _
*(Required for areas of special flood hazard)
LEGAL DESCRIPTION L-ol 2.f? e LoT zc:. . ~lf>~ef'( SuS~\\l\S\~. cs. Ti----, . I ,
APPLICANT'S INFORMATION (Pr imary Contact for the Project):
:=~~A~~! ,;:~u~~~~ E-Mail
City e .. c;z t State _"Li_.__,,,.tb'-'----Zip Code =::t-1:--HS:
Phone Number :.\=f.ok '114 .3 Fax Number ~4:-·=:3-"'.:J 9f
PROPERTY OWNER 'S INFORMATION : \
Name -SAL\1-1\ \? t-A-A\L-E-Mail ~~"'1'AIL(OC~ e+\-n~D-\ ·. StreetAddress~\~~~~~~~~~~~~~~~~!\~~~~~~~~~~~----------~ ~
City L. ,.:::; State -r><..
Phone Number 9'1C\ -S1 'f-'6rDI
Zip Code ']1 ~~ .J
Fax Number gr-iq-aGO ,.. ~/ 09,,
ARCHITECT OR ENGINEER'S INFORMATION:
Name ~o~ S~1J1. .. r z:... /rE%CfJN
Street Address------------------------------
City State_______ Zip Code _______ _
Phone Number -::\-4' 4=3'143 Fax Number :3(et{' ::r1-5 'f
Application is hereby made for the following development specific site/waterway alterations :
ACKN OWLED ~MENTS : ~At.IN>. \SM"\T.;: ~.._
~. {;!esign engineer~ereby acknowledge or affirm that:
The information and concl u_sions contained in the above f'lans and supporting documents comply with the
current re u· 't of College Station , T If Code, Chapter 13 and its associated Drainage
P · and
Property Owner(s)
6/13/03 1 of2
".
•'.
\ )
(
As a condition of approval of this permit application, I agree to construct the improvements proposed in this
application according to these documents and the requirements of Chapter 13 of the College Station City Code
Contractor
CERTIFICATIONS:
A. I, __ , certify that any nonresidential structure on or proposed to be on this site as part of this
application is designated to prevent damage to the structure or its contents as a result of flooding from
the 100-year storm .
Engineer Date
B. I, __ , certify that the finished floor elevation of the lowest floor , including any basement, of any
residential structure, proposed as part of this application is at or above the base flood elevation
established in the latest Federal Insurance Administration Flood Hazard Study and maps , as amended.
Engineer Date
C . I, __ , certify that the alterations or development covered by this permit shall not diminish the flood-
carrying capacity of the waterway adjoining or crossing this permitted site and that such alterations or
development are consistent with requirements of the City of College Station City Code, Chapter 13
concerning encroachments of floodways and of fl oodways fringes.
Engineer Date
D. I, __ , do certify that the proposed alterations do not raise the level of the 100 year flood above
elevation established in the latest Federal Insurance Administration Flood Hazard Study .
Engineer Date
Conditions or comments as part of approval: ------------------------
In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be
taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets,
or existing drainage facilities . All development shall be in accordance with the plans and specifications
submitted to and approved by the City Engineer for the above named project. All of the applicable codes and
ordinances of the City of College Station shal I apply.
6/13/03 2 of 2
Date:
To:
From:
Sub ject:
Remarks:
TEX, CON
TRANSMITTAL
Ju ly 15 , 2005
Caro l Cotter
Development Services
City of College Station
Joe Schultz, P .E. ~
Texcon General C{?;tractors
1707 Graham Road
Co llege Station, Texas 77845
Phone: (979) 764-7743
Sanitary Sewer Construction Drawings
Liberty Subdivision Re-Plat
Co llege Station, Texas
Attached are 2 sets of the Construction Drawings for the above-mentioned
project, 2 copies of the Engineer's Construction Cost Estimate, and 2 copies
of the Sanitary Sewer Design R eport. The sewer line is n ecessary in order for
Lot 2 to be platted as 3 separate lots .
Additional easements will need to be added to the Re-Plat for the sewer line.
Also , due to the shallow depth of the sewer lin e, minimum finish floor
ele vati ons need to b e shown on th e plat so that the buildings constructed on
the lots wi ll drain to the sewer line. This infonnation has also been
transmitted to KelT Surveying, LLC to include on the Re-Plat.
Let me know if you need anyth in g else or have any questions.
~
2,'CO
/-/)_;OS-
0 )-\Id--
CONSTRUCTION COST ESTIMATE 15-Jul-05
SANITARY SEWER IMPROVEMENTS
LIBERTY SUBD IV ISION
COLLEGE STATION, TEXAS
Item Estimated Unit Estimated
No. Description Quantity Price Cost
1 Mobilization/Layout 1 LS $1 ,200 .00 $1,200
2 Site Preparation/Clearing 1 LS $1 ,000 .00 $1,000
3 Silt Fence 410 LF $2 .75 $1, 128
4 8" Ductile Iron Pipe -cement sand backfill 412 LF $27.50 $11,330
5 Manholes < 6' deep 2 EA $1,850 .00 $3,700
6 Connect to existing manhole 1 EA $650 .00 $650
7 Install end seals for casing 4 EA $100 .00 $400
8 Install casing s pacers 11 EA $100.00 $1, 100
9 TV Inspection 412 LF $3.50 $1,442
TO TAL $21,950
Design Report
Proposed Sanitary Sewer Line Improvements
for
Liberty Subdivision
College Station, Texas
July 2005
Prepared By:
TEXCON General Contractors
1707 Graham Road
College Station, Texas 77845
(979) 764-7743
1.0 LNTRODUCTION & DESCRIPTION
The purpose of this report is to provide a description of the proposed san itary sewer to be
construct ed with the Liberty Subdivision for Lots 2A, 2B & 2C, and to provide the criteria
used in the design of this sanitary sewer system. The project wi ll include the construction
of approximately 412 feet of sanitary sewer line. This line and the existing lin e wi ll
service the proposed development of the four commercial lots making up the Libe1iy
Subdivision.
2.0 SANITARY SEWER-Design Flow and Pipe Size Calculations
The proposed sewer line is to be constructed of 8" diameter ductile iron pipe, class 350.
The proposed manholes are 4' diameter manholes, and vary from 3' to 6' in depth, with
sewer line slopes of 0.4%. The maximum distance between manholes is less than 500 feet,
as required by the Texas Commission on Environmental Quality (TCEQ). The minimum
allowable slopes for 8" pipe per TCEQ requirements is 0.33%. All construction shall meet
the current City of College Station Standard Specifications for Sanitary Sewer
Construction. The sewer line information is summarized in Table 1.
3.0 DETERMINATION OF PEAK FLOW VALUES
The average daily flow for Lots 2A, 2B & 2C was determined by using 30 persons per acre
(rate for commercial land use from B/CS Unified Design Guidelines, Sewer Design, pg. 4),
and then multiplying this by an average daily flow of 50 gprn/person (pg. 11, Table III,
Commercial/Office). The peak flow was then determined by multiplying the average daily
flow by 4.0. For Lot 1, a peak flow of 183 gpm was obtained from calculations performed
with the Holiday Inn development. The ve locities for the lines were calculated using
Manning's Equation. According to the TCEQ, the minimum velocity for sewer systems
flowing full is 2.0 feet per second. As shown in Table 1, the minimum anticipated flow
velocities for the proposed sewer lines at 50% full meet this requirement. The flow for
100% full will not be less than the flow for 50% full; therefore, the TCEQ requirement is
met. The TCEQ requires that the maximum velocity for sewer systems flow full not
exceed 10 feet per second. The values in Table 1 are well below this maximum velocity.
4.0 CONCLUSIONS
It is our determination based on the criteria and data developed that the proposed sewer
line will provide sufficient capacity for the anticipated wastewater flows generated by the
development of these four commercial lots.
Table 1
Liberty Subdivision -Sewer Line Flow Data
0 Manhole Averag e z Size length Slope Peak Flow
Cll Number Daily Flow c:
::i From To (in) (ft) (%) (gpm) (cfs) (cfs)
3 2 8 6 1.1 0.40 3.90 0.008 7 0 .0348
·-----------------------··---~ -·-----
";-2 1 8 351.2 0.40 1.70 0.0038 0.01 52 ---------------·-------------------en 8 173.4 0.40 2 .50 0 .00 56 0 .0223 1 Existing ·------------
From Holi da y Inn site • 0.407 7
•Peak Flo w obtain ed from Holiday Inn proj ect ca lcul ations . (183 gpm = 0 .40 77 cfs)
n = 0 .0 13
Refer to construction drawing s for manhole lo cation s .
Cu m ulativ e Percent 50 % Full
Pea k Flow Full Flow Veloc ity
(cfs) (%) (cfs) (fps)
0 .0348 14 .5 0 .3821 2.2 ----·-----------·
0.049 9 17 .3 0 .382 1 2.2 ----·--------
0 .0722 20 .8 0 .3821 2.2 ---------·--
0.4799 57 .4 --
N/F
STEPHEN A. MADISON AND
DIANE KAY MOMOO A-MADISDN. TRUSTEES
9.143 ACRE TRACT
VOL. 3783, PG. 113 (2261/29)
ZONED C-1
VI
I
"'
VI
I
"'
"' I
"'
Sta. 1+71 .73
Existing MH No. 1
LOT2B
BLOCK l
MIN. FF=2 83.50
HOLI DA Y INN
FF-285.00
16,755 SF
BL O CK l, LO T 1
2.763 AC RES
I r __________________ J
--~::---;----;--9 -hl 9-_,.
I ------------------------1
I
I
I
SEWER LINE S-1 I
SCALE : 111 =60 1
~··-··-
---e-.11·
I· -- -•(r r--/~
I v~ I , . a.....__, .
r------------------
1
I
I
I
I
I
I
I
I
LO T2C
BLO CK l
MIN . FF =285.0C
I Sta . 5+26.91
I Proposed MH No. 2
Sta. 5 +92 .00
Proposed MH No . 3
LOT2A
BLOCK 1
MIN. FF=285.00
EXHIBIT A
,
Design Report
Proposed Sanitary Sewer Line Improvements
for
Liberty Subdivision
College Station, Texas
July 2005
Prepared By:
TEXCON General Contractors
1707 Graham Road
College Station, Texas 77845
(979) 764-7743 _ .... "t:>.,,,,,
---'\ E. OF -,. \l ; co"'-'!>-••••••••••• ~-t-'•
r .. ·· *· ... ..,IP•• , * • . ,
'-*: ·.* ~·············· ~ * ~ l JOSE PH ·;;··s•t .... ·······'I. l~· ............. : •••• H~ULTZ If . v. .... ..
\~ 658~ I f ~ ·f.o ~~· . .. .,, . ..,
NAL €.~~ '~-
7,.15-fJS
1.0 INTRODUCTION & DESCRlPTION
The purpose of this report is to provide a description of the proposed sanitary se wer to be
constructed with the Liberty Subdivision for Lots 2A, 2B & 2C, and to provid e th e crit e ria
used in the design of this sanitary sewer system . The project will include the construction
of approximately 412 feet of sanitary sewer line. This line and the existing lin e will
service the proposed development of the four commercial lots making up the Liberty
Subdivision.
2.0 SANITARY SEWER -Design Flow and Pipe Size Calculations
The proposed sewer line is to be constructed of 8" diameter ductile iron pipe, class 350 .
The proposed manholes are 4' diameter manholes, and vary from 3' to 6' in depth, with
sewer line slopes of 0.4%. The maximum distance between manholes is less than 500 feet ,
as required by the Texas Commission on Environmental Quality (TCEQ). The minimum
allowable slopes for 8" pipe per TCEQ requirements is 0 .33%. All construction shall meet
the current City of College Station Standard Specifications for Sanitary Sewer
Construction. The sewer line infom1ation is summarized in Table 1.
3.0 DETERMINATION OF PEAK FLOW VALUES
The average daily flow for Lots 2A, 2B & 2C was determined by using 30 persons per acre
(rate for commercial land use from B/CS Unified Design Guidelines, Sewer Design, pg. 4),
and then multiplying this by an average daily flow of 50 gpm/person (pg. 11 , Table III ,
Commercial/Office). The peak flow was then determined by multiplying the average daily
flow by 4.0. For Lot 1, a peak flow of 183 gpm was obtained from calculations performed
with the Holiday Inn development. The velocities for the lines were calculated using
Manning's Equation. According to the TCEQ, the minimum velocity for sewer systems
flowing full is 2.0 feet per second. As shown in Table 1, the minimum anticipated flow
velocities for the proposed sewer lines at 50% full meet this requirement. The flow for
100% full will not be less than the flow for 50% full ; therefore, the TCEQ requirement is
met. The TCEQ requires that the maximum velocity for sewer systems flow full not
exceed 10 feet per second. The values in Table 1 are well below this maximum velocity .
4.0 CONCLUSIONS
It is our determination based on the criteria and data developed that the propos ed sewer
line will provide sufficient capacity for the anticipated wastewater flows generated by the
development of these four commercial lots .
Table 1
Liberty Subdivision -Sewer Line Flow Data
0 z Size Length Slope
Average p eak Flow
..-
' en
3
2
2 8 61 .1 0.40 3.90 0.0087 -·----------
8 351 .2 0.40 1.70 0 .0038 -------· -----·-----------
8 173.4 0.40 2 .50 0 .0056
Existing --
From Holiday Inn site
•Peak Flow obtained from Holiday Inn project calculations . (183 gpm =
n = 0 .013
Refer to construction drawings for manhole locations .
(cfs)
0.0348
0.0152 -
0.0 223
• 0.4077
0.4077 els)
-
Cumulative Percent 50% Full
Peak Flow Full Flow Veloc ity
(cfs) (%) (cfs) (fps)
0 .0348 14 .5 0 .3 821 2.2
--------
0.0499 17 .3 0 .382 1 2 .2 -·----..
0 .0722 20 .8 0 .3 821 2 .2 --------
0.4799 57.4 --
11
I
I!
li ~i
1,
-I I
i
N/F
STEPHEN A. MADISON AND
DIANE KAY MOMODA-MAOISON , TRUSTEES
9.143 ACRE TRACT
VOL. 3783, PG . 113 (2261/29)
ZONED C-1
I
I
"'I ~I
I
I
I
I
"'I ~I
I
I
I
I
"'I ~I
I
I
Sta. 1+ 71. 73
Exist i ng MH Na. 1
LOT2B
BLOCK 1
MIN . FF=2 83.50
HOLIDAY INN
FF-285.00
16 ,755 SF
BLOCK I , LOT I
2.763 AC RES
I
,------------------J
I
I
I
n
e-1': --
----,(?::; r---
1\/! i ./ a___, .
'----,------------------
' I
I
I
I
I
I
I
I
I Sta. 5+26.91
I Proposed MH No. 2
LOT2C
BLOCK l
MIN. FF=285.00
---s-8 ---'-1-~--"""""J...di
-----------------I
---S-8 ---S-8
-----1
I
SEWER LINE S-1
I 11 I I I
I
I l' I
SCALE : 1 "=60'
I EXISTING DRJVEW A. ~· --. ..:-
-1----------------------------=-::::·_ ::-::-:::-
Sta. 5+92.00
Proposed MH Na . 3
LOT2A
BL OC K 1
MIN . FF=285.0 0
EXHIBIT A