HomeMy WebLinkAbout5 Development Permit 201 R Bradley Subd;-
DRAINAGE REPORT
FOR
LOT 38R, BLOCK 14, SOUTHWOOD -SECTION 25
PREPARED FOR:
Walter Bradley
1302 Augustine CT.
College Station, Tx. 77840
PREPARED BY:
Municipal Development Group
P.O. Box 9249
College Station, Tx. 77842
Approved by
North Bardell, P.E.
E '0719 ~
TABLE OF CONTENTS
I. General Location
II. Property Description
III. Drainage Basin Descri ption
IV. Drainage Facility Design
V. Runoff Calculations
A. Creek Drainage
8. Southwood Drainage
VI. Conclusions
VII. Proposed Detention Facilities
LIST OF FIGURES
1. Figure 1: Site Drainage Plan
2. Figure 2: Drainage Area Map
3. Figure 3: Storm Volume Hydrograph
4. Figure 4: Storm Volume Hydrograph
(Creek Drainage)
(Southwood Drainage)
5. Figure 5: Flow Regulating Weir (Creek Drainage)
LOCATION OF STUDY SITE
General Locat_ion:
The subject tract is Lot 38R, Block 14 of the Southwood Section 25 Subdivision
of the City of College Station. The tract is positioned on the west side of
Southwood Drive, approximately one block north of FM 2818 (West Bypass). The vi"
Valley View Drive-Southwood Drive intersection is across from this tract, and it
will allow a joint intersection with the proposed street serving this tract.
Property Description:
Lot 38R, Block 14 of the Southwood Section 25 Subdivision of the City of College
Station is a total of 2.78 acres. The land is currently unimproved grass, weeds,
and trees in its natural state. It is rolling in nature, with elevation variation
from 286+ down to 272-. The 100-flood lain encroaches a roximatel .008
acres on the southwestern corner of the tract at an elevation of approximately
270.50 feet. Approximately one quarter of the tract (the most easterly) drains
rn a sheet-flow manner over the existing curb onto Southwood Drive. The
remaining three quarters of the tract drains onto surrounding properties, with /
most of the area (95%) draining into a defined channel on the most westerly end
of the tract. In addition, this tract currently drains the neighboring lots (Lots
39D and 39E) through a concrete headwall located at the southern portion of the
tract.
Drainage Basin Description:
The subject tract is located in Basin #5 of the Bee Creek Primary Drainage
System on Tributary "B" confluence, and thus requires detention facilities for a ~
100-year ultimate rainfall. (See Page 10 of the City of College Station "Drainage
Policy and Design Standards"). .008 acre of the tract, or proposed construction
thereon, is within the FEMA established flood plain (elev. 269.5).
Drainage Facility Design:
There is no proposal to change the existing drainage patterns, as they currently
create no flooding problems or hazards to surrounding properties. The proposed ~
development on this tract will add approximately 44,680 square feet of
impermeable roof, street, parking lot, or sidewalk surface area.
The increased runoff due to this impervious area will necessitate the prov1s10n
of two detention areas. The first detention area will be situated north of the
southern depressed area of the tract which currently drains Lots 39D and 39E.
This depressed area (.1063 acres) will be left in its natural state in order to
keep existing drainage conditions which currently does not pose a flooding
threat. This bermed detention area will be located at the western end of the
tract with a control outlet which will detain the projected increase in runoff
calculated for a 100-year frequency rainfall.
A second detention area will be located at the northwestern parking area. This
area will detain the projected increase in runoff calculated for a 100-year
frequency rainfall. A curb cut will be located at the western end of the parking
lot, which will drain water in a sheet-flow manner onto Southwood Drive.
000278-C.02-04(2270)
RUNOFF CALCULATIONS
I. Drainage to Creek
A. Pre-Development
Description
Grassland
B. Post-Deve lopment
Description
buildings
sidewalks
access drive &
parking
landscaped area
Area
2.079
Area
0.211569
0.014091
0.59656
1.27
2.079
c
0 .35
c
0 .9
0 .9
0.9
0.35
(c)(Ar ea)
0 .72765
(c)(Area)
0 .190412
0.012682
0.536904
0.4445
1.184498
Useful c = 1.184498/2 .079 = .566
••• Use Tc = 10 minutes •••
C. Runoff
O=clA
Opre = 1(.35)(2.079) = .72765(1)
Qpost = 1(.566)(2.079) = 1.1767(1)
Storm Fre .
5
10
lntensit
7.7
8.6
5.603
6.258
0 ost
9.061
10.1 2 0
25 9.9 7.2 04 11.649
50 11.1 8.077 13.061 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .......... .
< :::: < :t oo <<< ..... > t2 :s:::<: : : :: 9A s:a :: < :::::f .. t 82 :6>
Projected allowable rote of release from detention = 9 .2 c. f.s.
Storage Volume Hydrograph
Drainage to Creek
figure 3
16 -.----~~~~~~~-~~~~~~~~~~~
14.83
14 ....................................................................................................................................................................................... .
12 ····---····---··································· ""1"334 7"6".f .............................................................................................................. .
1 0 ..................................................................................................... ··········--~~-g~---~~-~~-~~-!g _~---························
9.17 5094 c.f.
8 ................................................................................................................................................................................... .
8253 c.f. 6 ..................................................................................................................................................................................... .
o ----~~~~~~~~~~~-.-~~~~~~
0 10 20 . 30
Time (m in)
Storm
5
10
25
50
100
Storm
5
10
25
50
100
BRADLEY REGULATORY WEIR DESIGN
Detention Characteristics
Allow. release rate Req. detention 'Waterline height
ft ...... 3/sec ft ...... 3) ft
5.6 3112 1.90
6.26 3476 2.10
7.2 4000 2.50
8.08 4486 2.75
9.17 5094 3.13
Regulated Flow Characteristics for Weir
y
ft
1.35
2.1
2.5
2.75
3
A Release Rate
ft
0.45
0.7
0.833
0.917
1
Flo~ Regulating Weir
Figure 5
ft"-3/sec
1.82
4.41
6.25
7.57
9.00
II. Drainage to Southwood
A. Pre-Development
Description
Grassland
B. Post-Development
Description
buildings
sidewalks
access drive &
parking
landscaped area
Area
0.7
Area
0 .0827
0.0058
0.0827
0.424
0.5972
g_
0.35
c
0.9
0.9
0.9
0.35
(c)(Area)
0.245
(c)(Area)
0.07 443
0.00522
0.07 443
0.1484
0.30248
Useful c = 0.30248/.5972 = .506
•••• Use Tc = 10 minutes ••••
C. Runoff
Q=clA
Qpre = 1(.35)(.7) = .245(1)
Qpost = l(.50_6)(.5972) = 0.302(1)
5 7.7 1.887 2 .325
10 8.6 2.107 2.597
25 9.9 2.426 2.990
50 11.1 2.720 3.352 . . . . . . . . . . . . . . . . . . . . . ... ' ..... ><::::: >>::totL>::::::::: ::::::::: ::::::t2 ;s:<::: : : >3:;o:a:7 : :<<<3J3os : . : :
Projected allowable rate of release from detention = 3.09 c.f.s.
·o
Storage Volume Hydrograph
Drainage to Southwood
figure 4
4 -r-~~~~~~~~~~~~~~~~~~
3 .81
3.5 ...................................................................... ··················································································································
3 ·············-~-~:~.~:~: .......................... -=-3. . .9~ .................................... .13.~q~ ... P..~~-~D~~.Q~L ........................ .
648 c.f.
2.5 ................................................................................................................................................................................... .
2781 c.f. 2 .................................................................................................................................................................................... .
1.5 .................................................................................................................................................................................... .
1 ...................................................................................................................................................... ································
0.5 ...................................................................................................................................................................... ···············
o ~~~~~~~~~~~~~~~~~~~
0 10 20 30
Time (min)
CONCLUSIONS
From the previous pag es of calculations of runoff quantities for the
drainage to the creek and to Southwood Drive, it can be seen that a maximum
pre-development runoff rate for the creek is 9.2 c.f.s. The maximum pre-
development runoff rate of 3.09 c.f.s. exits for runoff to Southwood Drive.
A V-Notch Weir having a top width o feet and a length o 5.7 eet will
simulate pre-development discharge rates or a 100, 50, 25, 10 5 year
frequency storms for the planned drainage to the creek (see fi g. 5 ):
**Table 111-2, College Station Drainage Policy And Design Standards:
V (overland flow at 3% grade with:;_..-.1.,......,...s"-!c::!a:..!p::.:e::_-d area) = 3.0 ft/sec
aterline:
Q = (3.0 ft/sec)(3.0 ft.)(1.0 ft. = c.f.s.
In the northwestern parking area, a flume having a standard section of 2
feet by 0.5 feet will provide a maximum discharge rate of approximately 8.0 c.f.s.
for the pavement surface. The discharge rate will adequetly satisfy the need for
3.09 c.f.s. in the event of a 100 year storm:
**Table 111-2, College Station Drainage Policy And Design Standards:
V (impervious area at 3% grade) = 8.0 ft/sec
Q= (1 ftA2)(8 ft/sec) = 8.0 c.f.s.
Due to the infinitesimal difference between pre development and post development
flow rates, water will be allowed to drain in a sheet like manner onto Southwood
Drive.
Proposed Detention Facilities
Bermed Detention Area
The enclosed site drainage plan depicts this detention facility in the southern
portion of the subject tract. This facility will provide a capacity of
approximately 6280 cubic feet of storage space which satisfies the requirement
of 5094 cubic feet. The centerline grade to the weir will be at .51% in order to
maintain a volumetric flowrate of 9.0 c.f.s. which is comparable to the pre-
development flow rate. In addition, the weir is a v-notch design in order to
simulate predevelopment conditions for various frequency storms. The outlet
structure leading to the bermed area will utilize an 18 inch RCP in order to
balance inlet and exit flows.
Northwestern Parking Area
The enclosed site drainage plan depicts this detention facilit;y in the
northwestern portion of the subject tract. This parking area is designed to
provide 650 cubic feet of storage space which is the projected requirement for
a 100 year frequency storm. The flume is designed to have a volumetric flowrate
of 8.0 c.f.s which satisfies the projected allowable release rate. A 5 foot by 5
foot block of sod will be provided in order to keep erosion at a minimum and to
convert the concentrated stream into a wider flow pattern which will sheet flow
on to Southwood Drive. In addition, an access drive will exist in the most
northern portion of the tract, which will allow for further drainage. This access
drive will mirror predevelopmental tendencies for sheet flow action onto
Southwood Drive.
£b/ slj lo p, f\ 11 Zl
<Z6/b}6 P1°0 zJ
I \
' I ' I
\
I
~ .• :;,_~:_. •' ' .. ~:".!~
MUNICIPAL DEVELOPMENT GROUP
P.O. Box 9249
203 Holleman Drive East
College Station, Texas 77840-9249
( 409) 693-5359
DATE JOB NO .
2Z'70
ATTENTION
RE :
WE ARE SENDING YOU ~ttached D Under separate cover via _________ the following items:
COPIES
D Shop drawings
D Copy of letter
DATE
D Prints
D Change order
NO.
~I ans D Samples D Specifications
o ______________________ _
DESCRIPTION
ll1t.. C..o
THESE ARE TRANSMITTED as checked below :
~For approval
D For your use
D As requested
D Approved as submitted
D Approved as noted
D Returned for corrections
D Resubmit __ copies for approval
D Submit __ copies for distribution
D Return __ corrected prints
D For review and comment D -------------------------
D FOR BIDS DUE _________ 19 ___ D PRINTS RETURNED AFTER LOAN TO US
REMARKS ----------------------------------------~
COPY TO _____________________ ~ ~ /"
SIGNED : QA=-~ f'0, ~
It enclo s11res are not as noted, kindly notify us at once.
·-
Figure XII
Application Form
Development Permit
Inside/Outside Established Flood Hazard Areas
City of College Station, Texas
(re: Ordinance No. 1728)
Site Legal Description: ~ot 178 f? J @ )i?O'~ 14 1 0ov-±tt woad 9ev VS
JZrj(Le., Site Address: i I ~Cl g~llfh lUtJOd
Owner: lAfi . l f.el( /;,. t?rur d {e V, Address: I ?;Jo1--tl ll4fl.Jf?ffn~ Cf .C:..17v
Telephone No.: ~?.7-qg8'2 7
Architect/ Address: U'IJ ~~ w~t~ \x
Engineer: -'M:........:.iotZ'--'~""4o---------------Telephone No.: ~2-4
Contractor: _Joe-~~ ]sk,W\e.? Address: ~O '? 1wa~ Ave . No l0f3 ~ Telephone No.: 0 q& l/zoB'
Date Application Filed: _q--=--J_/ o__,_l q_,_Q---=----------Approved:----------
Attached as part of this application:
D Application Fee
0' Signed Certificate
D Site and Construction Plans, with supporting documentation: two (2) copies of each{pY.evidV~VJ «1bm1"/W j
D Other:-----------------
ACKNOWLEDGEMENTS:
I, Na,lf.&V l· ~(~ , as owner, hereby acknowledge or affirm that:
The above Drainage Plan and supporting documents complies wiht the requirements of Ordinance No. 1728,
and
Date
.~~I°! 11 0,3
Oat
Page 1of2
Figure XII Continued
CERTIFICATIONS:
A. I, certify that any nonresidential structure on or
proposed to be on this site as part of this application meets flood-proofing requirements as
set out in Section of Ordinance No. 1728
Architect/Engineer Date
B. I, N OR.TH B l3rtBJ:>ELL-JR.;, certify that the finished floor level of the lowest
floor, including any basement, of any residential structure as part of this application is or
proposed to be at or above the base flood elevation as established in the latest Federal
¥' l~n~ ha~~ study and maps, as ;;~nd;~ '!
3 Architect/Engineer J--~;;;;;D-a....,t F--''--~=--t7-_,__.._-=~----
C. I, certify that the alterations or development covered
by this permit shall not diminish the flood-carrying capacity of the adjoining waterway or
crossing this permitted site and that such alterations or development are consistent with
requiremenrs concerning encroachments of floodways and of floodway fringes as illustrated
in the latest Federal Insurance Study.
Architect/Engineer Date
D. I, do certify that any alterations, addressed in
Certification ''D" do not raise the level of 100-year flood as referred to Certification 11 8 11
•
Architect/Engineer Date·
REVIEWED FOR AP PROV AL:
----~=---..,~..,..-~-,........,.--~ Floodplain Administrator Date
APPROVAL: Special conditions or comments as part of approval: ------~---
Pal!e 2of2
y..,.~PI'·"°"
l::M
DEVELOPMENT PERMIT
PERMIT NO. 0201R
FOR AREAS OUTSIDE THE SPECIAL FLOOD HAZARD AREA
RE: CHAPTER 13 OF THE COLLEGE STATION CITY CODE
SITE LEGAL DESCRIPTION:
Lot 38R, Block 14, Southwood Sec 25
SITE ADDRESS:
2100 Southwood Drive
OWNER:
Walter L. Bradley
1302 Augustine Ct.
College Station, Texas 77840
DRAINAGE BASIN:
Bee Creek
TYPE OF DEVELOPMENT:
This permit valid for all construction associated with the Bradley Subdivision. All
construction shall be in accordance with the plans submitted. Contractor shall prohibit
all debris from construction including dirt and silt, from entering public streets and
drainage facilities. Contractor shall be responsible for any damage to existing streets,
curbs, or public infrastructure due to the construction activities. Contractor shall
prevent construction vehicles from tracking dirt, mud, and debris from all exit points of
the project, onto any public street. Contractor shall use appropriate erosion control
measures such as silt fencing and hay bales to prevent silt and debris from exiting the
project site. It is the contractor's responsibility to erect and maintain the erosion control
measures throughout the project. Should sufficient mud and dirt accumulate on
public streets, it is the contractor's responsibility to install a washdown facility
for the construction vehicles entering and exiting the site.
SPECIAL CONDITIONS OF THIS PERMIT:
1) Erosion protection , in the form of silt screens , shall be installe d in accordance
with plans submitted and approved.
In accordance with Chapter 13 of the Code of Ordinances of the City of College
Station , measures shall be taken to insure that debris from construction, erosion ,
and sedimentation shall not be deposited in city streets, or existing drainage
facilities.
I hereby grant this permit for the construction of improvements as shown on
the approved plans and construction both inside and outside the special flood hazard
area. All construction shall be in accordance with th e plans and specifications
submitted to and approved by the City Engineer in the development permit
a ·cation for the above named project and all of the codes and ordinances of the
C of College St ion that apply.
Date / /
DEVELOPMENT PERMIT
PERMIT NO. 0201R
FOR AREAS OUTSIDE THE SPECIAL FLOOD HAZARD AREA
RE: CHAPTER 13 OF THE COLLEGE STATION CITY CODE
SITE LEGAL DESCRIPTION:
Lot 38R, Block 14, Southwood Sec 25
SITE ADDRESS:
2100 Southwood Drive
OWNER:
Walter L. Bradley
1302 Augustine Ct.
College Station, Texas 77840
DRAINAGE BASIN:
Bee Creek
TYPE OF DEVELOPMENT:
This permit valid for the grading, dirt work, and construction of the following: l)slabs
associated with the fourplexes, 2) water and sewer main construction. All construction
shall be in accordance with the plans submitted. Contractor shall prohibit all debris
from construction including dirt and silt, from entering public streets and drainage
facilities. Contractor shall be responsible for any damage to existing streets , curbs , or
public infrastructure due to the construction activities. Contractor shall prevent
construction vehicles from tracking dirt, mud, and debris from all exit points of the
project, onto any public street. Contractor shall use appropriate erosion control
measures such as silt fencing and hay bales to prevent silt and debris from exiting the
project site. It is the contractor's responsibility to erect and maintain the erosion control
measures throughout the project. Should sufficient mud and dirt accumulate on
public streets, it is the contractor's responsibility to install a washdown facility
for the construction vehicles entering and exiting the site.
SPECIAL CONDITIONS OF THIS PERMIT:
1) Erosion protection , in the form of silt screens , shall be installed in accordance
with plans submitted and approved .
In accordance with Chapter 13 of the Code of Ordinances of the City of College
Station , measures shall be taken to insure that debris from construction , erosion ,
and sedimentation shall not be deposited in city streets, or existing drainage
facilities.
I hereby grant this permit for the construction of improvements as shown on
the approved plans and construction both inside and outside the special flood hazard
area. All construction shall be in accordance with the plans and specifications
submitted to and approved by the City Engineer in the development permit
ap ·cation for the above named project and all of the codes and ordinances of the
Ci of College St tion that apply.
Date
Requirements for Final Drainage Report and Drawings
Developement: So.,./4.,001; 5ec.. 2 ~ 8/0c.! /'/, LJ~R Permit #: ---:----
Developer: W11/./cl' Brc.J/~v submitted By: /'Jor/~ f5o.rJ,//
1
P.£
Address: / .302 A.,llSJ;,,( Cl. Address: RO. Bew t:Jz tl'/
Col .. 'ik. TX 778~ Cl.51,, IA' 778Yd2 > >
Phone: Phone:
Date Submitted:
Date Reviewed:
D. Final Drainage Report and Drawings
1. The purpose of the Final Drainage Report is to identify and
define conceptual solutions to the problems which may occur
on site
reports
and off site as a result of the development. All
shall be typ ~on 8-1/2 " x 11" a er and bo ~
together. The report shall include a cover
presenting the proposed design for review and shall be
pr ~d by a Registered Professional Engineer lic ~d in
Texas. The report shall(z rntain a certification she"€]) 1.s
follows:
"I hereby certify that this report (plan) for the
drainage design of (Name of Develo pment ) was prepared by me
(or under my supervision) in accordance with the provisions
of the City of College Station Drainage Policy and Design
Standards for the owners thereof."
Registered Professional Engineer
State of Texas No.
(Affix Seal)
2. Report Contents
The Final Draina ge Report shall be in accordance with
the following outline an d contain the applicable
information listed:
a. General Location and Je s c r i ption
(1) Location
~ Local streets
development
withi n and adjacent to
Primar y Dra i.:.;:qe Sy stem drainageways
facilities
~Names of surr ound ing developments
0 1
the
and
...
(2) Property Description of
~~ Acreage tL~ f' ..... ,/ '-·•~;_. llf'K .\o..-WH . ) Land cover .}"' "°"'"" 1 <-__ _,,,.,. c . ) Primary and Seconda ry System drainageways
within the property DL9$CI; ,,_, :111 "l'°,J #fJ
~II'\ p/,t ~-----,1~.,;d.) General project descri ption
b. Drainage Basins and Sub-Basins
(1) Primary Basin Description
~ Reference to Primary Drainage System planning
studies such as flood hazard delineation
reports, and flood insurance rate maps.
Primary Basin drainage characteristics.
Secondary Drainage Basin Description -Discussion
of offsi te drainage flow patterns, and impact of • development on existing and proposed pathways to
Primary Drainage Sy stem.
(<.Ct.'rs ..}, JL. c . Drainage Design Crite r ia
C·J , ''[); . ~(l) Regulations -Discussion of the optional criteria
1 ys ""'~ selected or the deviation from the Standards, if Po !•c.y ,..,, ~.s1)'-
~.J.Js." any.
(2) Development Criteria Reference and Constraints
'' .J / ,,a .) Discussion of previous drainage studies for ""''ti\ .... o~#" . -
c"';.) .J"''' ii ~ ~,_I.
'Z~ 'f_N ~°'""
~°'i;o"-"'' HeJl.J
(3)
the site in question that influence or are
influenced by the drainage design and how the
plan will affect drainage design for the
site.
b.) Discuss ion of the drainage impact of site
constraints such as streets, existing
structures, and development or site plan.
Hydrological Criteria
~ Identif y design rainfall
~ Identify runoff calculation method
6 Identify detention disc harge and
calculation method, if any
storage
~Identify design storm recurrence intervals
N,~ ~*;/i•~ ""'iJL
~.;./i~ J,,,_ critH~.
(4)
e.) Discussion and justification of other
criteria or calculation methods used that are
not presented i n or
Standards .
referenced by the
H ~raulic Criteria
~) Identify various capacity references
/) Identify detention/retention outlet type, if
a n y .
c.) Discussion of other drainage facility design
criteria used that are not presented in the
Standards.
d. Drainage Facility Design
(1) General Concept
0" Discussion of concept and typical• drainage
patterns
v.) Discussion of compliance with offsite runoff
co nsiderations
t'J;"';n..,.I ~~ c.) Discussion of the content of tables, charts,
figures, or drawings presented in the report
d.) Discussion of
drainage patterns.
(2) Specific Details
anticipated and proposed
Noftt j,,.tLJ~J~ a.) Discussion of drainage problems encountered
and solutions at specific design points
~Discussion of detention storage and
e.
outlet
design, if any
Discussion of maintenance access and aspects
of the design
Con_5J.-usions
~ Compliance with Standards of the City of College
Station Drainage Policy and Design Standards
~ (2) Effectiveness of drainage design to control damage
from stormwater flows rz. (3) Explanation of the effectiveness of existing and
proposed improvements with regard to controlling
the discharges of the 100 year storm with ultimate
development conditions of the secondary system
basins affected by the proposed development.
E.
f.
g.
References Reference all criteria and technical
information used.
Appendices (Where Applicable)
(1) Hydrologic Computations
a.) Land use assumptions
'· properties
re gardin g a djacent
b.) Minor and major storm runoff at specific
design points
c.) Historic ~nd fully developed
computations at specific design points
d.) Hydrographs at critical design points
(2) Hydraulic Computations
a.) Culvert capacities
b.) Storm s~wer capacity
c.) Street capacity
runoff
d.) Storm inlet capacity including inlet control
rating at connection to storm sewer
e.) Open channel design
f.) Detention area/volume capacity and outlet
capacity calculations
Final Drainage Report Drawing Contents
1. Sheet #1 -General Location Map that
a. Depicts drainage flows entering and leaving the
development site;
b. Identifies major construction along path of drainage;
c. Illustrates general drainage flow within entire basin;
and
d. Is drawn at a scale of l "=500' to l "=2000' .
2. Sheet #2 -Floodplain Information
a. Copies of existing City of College Station 100-year
floodplain maps showing the location of the subject
development.
..
.
'
• ,
.
• , ! '
3. Sheet #3 Drainag e Plan Map(s) of the proposed
development at a scale o f l "=20 ' to l "=200' on a 24" x 36"
d rawing shall be i nc lud e d. The plan shall show t h e
fo llowing :
a . Exist ing an d pr o po s ed co n t o urs at 2-f e e t maximum
i nterva l s .
b. Propert y l i n e s, a n d e a s em ents wi th purposes noted.
c . Stree ts .
d. Existing dra i n ag e f a ci lit i e s, r o adside di t ches ,
draina gewa ys, g utter f l o w d irections, and culv e r ts .
All pertinent i n fo rm ati o n such as material, s ize,
shape, slope, and loc a ti o n s hall also be included.
e. Overall drainage ar ea bo und ary and drainage sub-area
boundaries.
f. Proposed type o f st r eet f l ow, roadside ditch, and/ o r
gutter flow dire c t io ns .
g . Proposed st o rm sewer s an d o pen drainageways, includin g
inlets, manholes, c ulv e r ts , a nd other appurtenances.
h. Proposed outfall po in t fo r runoff from the dev e l op e d
area and facilities to co nve y flows along the propos ed
pathways to the f inal o u tfa ll points in the pr i ma r y
drainage system wi th o u.t damage to downstream
properties, or e xceeding the capacities of the
receiving faciliti es as ~e f in ed in these standards.
i . Routing and ac c umulat !.•J n )f f lows at various crit ical
points for the min o r 5::r~ runo f f .
j. Path(s) chosen '.·'r :a mp utation o f t i me-of-
concentration.
k. Details of dete n t i •J'.". ~ »: ~~ t. i o n storage facilities a nd
outlet works.
1. Location and el e\· 1:: .-;
affecting the pr o per : ..
m.
n.
Location and el ev 3t:.:-.-;
utilities affect ed b~ ..
Routing of of fs i t.e
development.
n :;
)f a ll defined floodpla i ns
a ll e xisting and proposed
1::ect ing the drainage desi g n.
:~J i nag e flow through the
Mr. Ray Havens
Electric Transmission &
Distribution Superintendent
City of College Station
P. 0. Box 9960
College Station, Texas 77842
McCORD ENGINEERING, INC.
7607 Eastmark Drive, Suite 102 , P.O. Box 10047
College Station , Texa s 77842 (409) 764-8356
Fax (4 09) 764-9 644
September 27, 1993
Re: Bradley 4-Plexes Electric Service
Dear Ray:
As requested, we have prepared a proposed electric distribution layout to serve the
Bradley 4-Plexes being constructed on Southwood Drive. Shown on the enclosed five (5)
copies of our electric distribution layout for these 4-plexes are our recommendations regarding
underground primary cable runs, transformer locations and sizes required, ganged meter
locations, service installations , etc. A diskette has also been enclosed which includes this
project electrical layout for your use .
I
1 The electric system distribution layout for this complex has been planned to be installed I underground, as per the request of the Developer. Two (2) standard stock 50 kV A and two
'1 (2) standard stock 37.5 kVA, single-phase , 7200 volts to 120/240 volt transformers are
proposed to provide service to this apartment complex. Y ,, ; In accordance with the new policy of your City, the Developer is responsible for
"" j / reimbursing your City for 20 % of the total estimated cost of electric service installation,
..-I including labor, materials, and the standard fee percentages for engineering and overhead cost.
j We compute that the 20% cost contribution required for the Bradley 4-Plexes amounts to
! $1, 750.00. This cost was calculated based on a total electric service cost estimate of
$8,750.00. The total electric service cost estimate developed for this project includes on 1·
standard allowance of 30% to cover your City's labor related overhead costs, 7 % for material
handling costs, and 8.5% to cover your City's administrative and engineering costs . I
Please advise if you need further information on this matter.
IDM/mw
Enclosures
cc: Mr. David Pullen (w/encl.)
Yours very truly,
Mer]"~ ENGINEERI~, INC.
0 ~ "1;), M L7J!.
Jimmy D. ~cCord , P.E.
President
~~~
~ ~~<L . fJ1i~ WU<-~.~~
OOf w ~¥db ;<w.cl~~-
v~(µ
0
MUNICIPAL DEVELOPMENT GROUP
P.O. Box 9249
203 Holleman Drive East
College St at ion Texas 77840 9249 , -
(409) 693-5359
Sh1rl-ey Volk
CIT'( or ( ol!eq< S+1rh oVJ
WE ARE SENDING YO U ~ Attached D Under separate cover via
D Shop drawings D Prints oo' Plans
D Copy of letter D Change order D
COPIES DATE NO .
llAT·« IJ °-;__~~-ZI~ I b ~£Pt"'"""\\(?.,' 11?~
ATTEN T I O N
RC :
C:::.1 I ~
~~~
-,,,. \ Ol/
D Samples
the ?'ing item"
Specifications
!/
DESCR IPTI O N f!P'i
IS I b Sep~""\:.u ffB i-mq-1...7<& .fSrz A f'l LEY <;,, Rf")i• .,c;""" : f'Fl.n>">oSCO Wf\-TER Al.I"' sr::1 .• ~., T""""0 ~. --·rvr..S
THESE ARE TRANSMITIED as checked below : ~
,.31 For approval
D For your use
D As requested
D For rev iew and comment
·o FOR BIDS DUE
REMARKS
D Approved as submitted
D Approved as noted
D Returned for corrections
D
19
D Resubmit __ copies for approval
D Submit __ copies for distribution
D Return __ corrected prints
0 PRINTS RETURNED AFTER LOAN TO US
COPY TO j ,/ cC/· /J
--------SIGNED: ~~
It encloaurH •r• not •• noted, lr indly notify ue •t one•.
---
----
-------
Veronica Morgan
Assistant City Engineer
City of College Station, Texas
North Bardell
Municipal Development Group
203 Holleman Drive East
College Station, Tx 77840
September 22, 1993
Re: F i re Flow calculations for Bradley Apartments (Lot 38R, Block 14, Southwood-
Section 25)
Veronica Morgan:
Below find the head loss (p.s.i.) figure for the pipe run leading to the
proposed fire hydrant shown on sheet 1 of 6 of the plans for the Bradley
Subdivision. These figures were taken from a nomograph representing the
Hazen-Williams formula using a coefficient of roughness of .017. This coefficient
gives a factor of safety as it represents flow in cast iron pipes and would be
less in the specified P.V.C. pipe. (We use this coefficient because of t!_le j fSt
previously installed pipe condition§ being somewhat unknown). . 1 ~_a, N O u ;._ -r rr:r,J cl' ~ h~~~::J-,t:J.~~~1° J (1 tr; ~ ~j)ol
e .. {,./f1e. t @ rM r1--a~s ~ z4~ {)(\ r 1'f.,'1,, •
, ~ 11"'l 11 <7 I · '~ (Jdllt>f'Waf(? flJ!.1 VG t-I
Head loss from pt. 1 to pt. 2 @ 1200 g.p.m. flowrate
175 ft/1000 x 55 ft. x .43 p.s.i./ft. = 4.13 p.s.i.
Head loss from pt. 2 to pt. 3 @ 1200 g.p.m. flow rate
175 ft/1000 ft x 130 ft. x .43 p.s.i./ft. = 9. 7 p.s.i.
Total head loss from supply line = 13.83 p.s.i.
Indicated Residual Pressure in 8" Supply line at fire flow conditions = 50 p.s.i.
Assumed residual pressure at proposed hydrant = 50-13.83 = 37.17 p.s.i.
Sincerely,
~13~
North B. Bardell
~r
MUNICIPAL DEVELOllMJ~N'I' GROUP
ENGINEERlNC, PLANNING, SURVEYING
----~·-·-----· -----···-----~--·-
• DATE 9. J''Z -7 3 FAX NO. 7 C,, 'l_ --~-<f.._2-'.t__._ NO. PJ\(1J.:S TO FOLLOW _ _L_~
l (I• d
TO ·-------
lf the1·e i:-; a pro )le/II with this trnnsmi.<;sfon, plt><l.'Sc ('<Jll 11s 11t 40a-693--.S:J5fl,
CONFIDE:-iTIALlTY NOTICE: This fac:;imifo mt.'.'>sage t-tnd aer~o111p..:ill} l"
commlinir.atiou ancl/or clot·1rnwnts ar·p intE-·11<frd for· tht• t:.·dw>ive mid < rmf1 '"nt ·
use of the in di vidiwl or entity to w hkh the lllP.!;.-agP i~ ;1dcfr e:;:;ed.
COMMEN'I'S~--~------
~-------------~~~~----~~-----------------
--.-.. --.-·~-·.··---
-------~-·~-~------
MU NICIPAI. DE\ ELOPM ENT CROlJP
203 lfoll(>111<t11 J)dvt' E~i:-;l
Collc!Je S l:.\ llon. TX 778 to
TEL (409) CD3-5350
FAX (400) COJ-4243
,. ,.1
•
•
z.0 • d
Estimated Water and .,~~wer Loadings for the Bradley Subdivision
Domes'tic Water: 400 g.p.d ./unit x 24 units = 9600 g .p .d •
9600 g.p.d. = 6.67 g .p.m . average flow
Peak Flow = 3.0 x average ;:; 20.01
Irrigation Water: 10± g.p.m. at peak
'.fotal_Peak _W~ter ~snand = 30.01 R'..!.E.tl!l..!.
Sanitary Sewage: 392 g.p.d./unit x 24 units : 9408 g.p.d.
Peak Flow = 2.25 x average ;;: 21.168 g.p.d.
DEVELOPMENT PERMIT
PERMIT NO. 0201
FOR AREAS OUTSIDE THE SPECIAL FLOOD HAZARD AREA
RE: CHAPTER 13 OF THE COLLEGE STATION CITY CODE
SITE LEGAL DESCRIPTION:
Lot 38R, Block 14, Southwood Sec 25
SITE ADDRESS:
2100 Southwood Drive
OWNER:
Walter L. Bradley
1302 Augustine Ct.
College Station, Texas 77840
DRAINAGE BASIN:
Bee Creek
TYPE OF DEVELOPMENT:
This permit valid for the grading, dirt work, and construction of the Bradly Subdivision
slab only. All construction shall be in accordance with the plans submitted.
Contractor shall prohibit all debris from construction including dirt and silt, from
entering public streets and drainage facilities. Contractor shall be responsible for any
damage to existing streets, curbs, or public infrastructure due to the construction
activities. Contractor shall prevent construction vehicles from tracking dirt, mud, and
debris from all exit points of the project, onto any public street. Contractor shall use
appropriate erosion control measures such as stltfenctng and hay bales to prevent silt
and debris from exiting the project site. It ts the contractor's responsibility to erect and
maintain the erosion control measures throughout the project. Should sufficient mud
and dirt accumulate on public streets, it is the contractor's responsibility to
install a washdown facility for the construction vehicles entering and exiting
the site.
SPECIAL CONDITIONS OF THIS PERMIT:
1) Erosion protection, in the form of silt screens, shall be installed in accordance
with plans submitted and approved.
In accordance with Chapter 13 of the Code of Ordinances of the City of College
Station, measures shall be taken to insure that debris from construction, erosion,
and sedimentation shall not be deposited in city streets, or existing drainage
facilities.
I hereby grant this permit for the construction of improvements as shown on
the approved plans and construction both inside and outside the special flood hazard
area. All construction shall be in accordance with the plans and specifications
submitted to and approved by the City Engineer in the development permit
a cation for the above named project and all of the codes and ordinances of the
C of College Station that apply.
DRAINAGE REPORT
FOR
LOT 38R, BLOCK 14, SOUTHWOOD -SECTION 25
PREPARED FOR:
Walter Bradley
1302 Augustine CT.
College Station, Tx. 77840
PREPARED BY:
Municipal Development Group
P .0. Box 9249
College Station, Tx. 77842
Approved by
North Bardell, P.E.
TABLE OF CONTENTS
I. General Location
II. Property Description
III. Drainage Basin Description
IV. Drainage Facility Design
V. Runoff Calculations
A. Creek Drainage
B. South wood Drainage
VI. Conclusions
VII. Proposed Detention Facilities
LIST OF FIGURES
1. Figure 1: Site Drainage Plan
2. Figure 2: Drainage Area Map
3. Figure 3: Storm Volume Hydrograph
4. Figure 4: Storm Volume Hydrograph
(Creek Drainage)
(Southwood Drainage)
LOCATION OF STUDY SITE
Gen e ral Lo ca tion:
The subject tract is Lot 38R, Block 14 of the Southwood Section 25 Subdivision
of the City of College Station. The tract is positioned on the west side of
Southwood Drive, approximatel y one block north of F~t 2818 (West Bypass). The
Valley View Drive-Southwood Drive intersection is across from this tract, and it
will allow a joint intersection wi th the proposed street serving this tract.
Propertv Description:
Lot 38R, Block 14 of the Southwood Section 25 Subdivision of the City of College
Station is a total of 2.78 acres. The land is currently unimproved grass, weeds,
and trees in its natural state. It is rolling in nature, with elevation variation
from 286+ down to 272-. The 100-year flood plain encroaches approximately .008
acres on the southwestern corner of the tract at an elevation of approximately
270.50 feet. Approximately one quarter of the tract (the most easterly) drains
in a sheet-flow manner over the existing curb onto Southwood Drive. The
remaining three quarters of the tract drains onto surrounding properties, with
most of the area (95%) draining into a defined channel on the most westerly end
of the tract. In addition, this tract currently drains the neighboring lots (Lots
390 and 39E) through a concrete head wall located at the southern portion of the
tract.
Drainage Basin Description:
The subject tract is located in Basin #5 of the Bee Creek Primary Drainage
System on Tributary "B" confluence, and thus requires detention facilities for a
25-year ultimate rainfall. (See Page 10 of the City of College Station "Drainage
Policy and Design Standards"). .008 acre of the tract, or proposed construction
thereon, is within the FEMA established flood plain (elev. 269.5).
Drainage Facility Design:
There is no proposal to change the existing drainage patterns, as they currently
create no flooding problems or hazards to surrounding properties. The proposed
development on this tract will add approximately 44,680 square feet of
impermeable roof, street, parking lot, or sidewalk surface area.
The increased runoff due to this impervious area will necessitate the provision
of two detention areas. The first detention area will be situated north of the
s outhern depressed area of the tract which currently drains Lots 39D and 39E.
This d e pressed area (.1063 acres) will be left in its natural state in order to
keep exi s ting drainage conditions which currently does not pose a flooding
threat. This bermed detention area will be located at the western end of the
tract wi th a control outlet wh i ch will detain the projected increase in runoff
calculated for a 25-year frequency rainfall.
A se c o n<l <letention ar e a will be located al the northwestern parking area. This
area wi ll detain the projected increase in runoff calculated for a 25-year
'frequency rainfa ll. A curb cut will be located at the western end of the parking
lot, which will drain water in a sheet-flow manner onto Southwood Drive.
000278-C.02-04(2270)
RUNOFF CALCULATIONS
I. Drainage to Creek
A. Pre-Deve lopment
Descriptio n
Grassland
B. Post-Development
Desc ription
bui ldings
sidewalks
access drive &
parking
landscaped area
Area
2.079
Area -
0.211569
0.014091
0.59656
1.27
2.079
c
0.35
c --
0.9
0.9
0 9
0.35
(c)(Area)
0.72765
(c)(Area)
0.190412
0.012682
0.536904
0.4445
1.184498
Useful c = 1.184498/2.079 = .566
*** Use Tc = 1 0 minutes ***
C. Runoff
Q=clA
Qpre = 1(.35)(2.079) = .72765(1)
Qpost = 1(.566)(2.079) = 1.1767(1)
Storm F re . lntensit . re ost
5 7.7 5.603 9.061
10 8.6 6.258 10.120
:::::::::::::::::::::::2 :s ::::::::::::::::::::::::::i:::::::~;:#:::::::::):::::::t ~:¢:w.::::::~::::::::r:J.;~:4:s.:::::::
50 11.1 8.077 13.061
100 12.6 9.168 14.826
Projected allowab le rate of release from detention = 7 .2 c.f.s.
Storage Volume Hydrograph
Drainage to Creek
Figure 3 12.,.--------------------.
10480.5 c.f.
10 .................................................................................................................................................................................... .
Req. Detention =
4000 c.f. 8 ··································································································· .................................................................................... .
0 --.
0-r-------r----~----~
0 10 20 30
Time (min)
II. Drainage to Southwood
A. Pre-Development
Description Area c {c}{Area}
Grassland 0.7 0.35 0.245
B. Pos t-Deve lopment
Description Area c (c)(Area)
buildings 0.0827 0.9 0.07 443
sidewalks 0.0058 0.9 0.00522
access drive &
parking 0.0827 0.9 0.07 443
landscaRed area 0.424 0.35 0.1484
0.5972 0.30248
Useful c = 0.30248/.597~ = .506
**** Use Tc = 10 minutes ••••
C. Runoff
Q=clA
Qpre = 1(.35 )(.7) = .245(1)
Qpost = 1(.506)(.5972) = 0.302(1)
Storm F re . lntensit re ost
5 7.7 1.887 2.325
10 8.6 2.107 2.597
::1::::::u::::::::::~:s :::::::;:::::~:::::::/::::::::::$.~:~::::::::::::::::::::2 :1 ~i:~:::::::::::::::::~:;$.~o ::::::::
50 11.1 2.720 3.352
100 12 .6 3.087 3.805
Projected allowable rate of release from detention = 2.43 c.f.s.
Storage Volume Hydrograph
Drainage to Southwood
Figure 4
3-.--~~~--~~~~~~~~~~
2690.82~
25 ....................................................................................................................................................................................... .
· -426 Req. Detention =
500 c.f 2 .................................................................................................................................................................................... .
2182.95
1 ........................ ············································································································· ................................................ .
0.5 ................................................................................................................................................................................... .
o-r-~~~-------,~~~~-,-~~~~~
0 10 20 30
Time (min)
CONCLUSIONS
With the use of the Rational Method for the calculation of runoff quantities
for the drainage to the creek and to Southwood Drive, it can be seen that a
maximum pre-development runoff rate for the creek is 7.2 c.f.s. The maximum
pre-development runoff rate of 2.43 c.f .s. exits for runoff to Southwood Drive.
A weir having a cross-section of 6 inches by 3 feet will provide a
discharge rate that will simulate a pre-development runoff at a rate of 7.1 c.f.s.
for the planned drainage to the creek:
Q = 1.49 AR111 s If!
n
Q = 1.49 (12.5)(.71428)2/J(,005)111
.015
Q = 7 .1 c.f.s.
Velocity = Q/ A
v =. 7 .1
1.25
V = 5.68 ft/sec
In the northwestern parking area, a flume having a section of 2 feet by
0.5 feet will provide a discharge of 2.27 c.f.s. which is similar to the pre-
development runoff rate of 2.43 c.f.s.:
Q = 1.49 AR!/J S 111
n
Q = 1.49 (1)(.3333)!/J(.00227)111
.015
Q = 2.27 c.f .s.
Due to the infinitesimal difference between pre development and post development
flow rates, water will be allowed to drain in a sheet like manner onto Southwood
Drive.
Proposed Detention Facilities
Bermed Detention Area
The enclosed site drainage plan depicts this detention facility in the southern
portion of the subject tract. This facility will provide a capacity of
approximately 4700 cubic feet of storage space which satisfies the requirement
of 4000 cubic feet. The centerline grade to the weir will be at .51% in order to
maintain a volumetric flowrate of 7.1 c.f.s. which is comparable to the pre-
development flow rate. The outlet structure to the bermed area will utilize an
18 inch RCP in order to balance inlet and exit flows.
Northwestern Parking Area
The enclosed site drainage plan depicts this detention facility in the
northwestern portion of the subject tract. This parking area is designed to
provide 500 cubic feet of storage space which is the projected requirement for
a 25 year frequency storm. The flume is designed to have a volumetric flowrate
of 2.27 c.f.s which meets the requirements of predevelopment flow. A 5 foot by
5 foot block of sod will be provided in order to keep erosion at a minimum and
to convert the concentrated stream into a wider flow pattern which will sheet
flow onto Southwood Drive.