HomeMy WebLinkAbout17 BTU Private Dr. 04-40~-v DEVELOPMENT PERMIT
PERMIT NO. 04-40
Project: BTU MAINTENANCE DRIVE
COLllGl STATION FOR AREAS OUTSIDE THE SPECIAL FLOOD HAZARD AREA
RE : CHAPTER 13 OF THE COLLEGE STATION CITY CODE
SITE LEGAL DESCRIPTION:
EDSEL JONES TRACT
ADJACENT TO SALLIE LN
AND STEEPLECHASE PARK
DATE OF ISSUE: 9/07/04
OWNER:
EDSEL JONES
TYPE OF DEVELOPMENT:
SPECIAL CONDITIONS:
Clearing Permit
SITE ADDRESS:
11775 WELLBORN RD
DRAINAGE BASIN:
Bee Creek Trib . "B"
VALID FOR 6 MONTHS
CONTRACTOR:
All construction must be in compliance with the approved construction plans
All trees required to be protected as part of the landscape plan must be completely barricaded in accordance with Section
7.5.E., Landscape/Streetscape Plan Requirements of the City's Unified Development Ordinance, prior to any operations
of th is permit. The cleaning of equipment or materials within the drip line of any tree or group of trees that are protected
and required to remain is strictly prohibited . The disposal of any waste material such as , but not limited to , paint , oil,
solvents , asphalt , concrete , mortar , or other harmful liquids or materials within the drip line of any tree required to remain
is also prohib ited .
EROSION CONTROL REQUIRED AS SHOWN ON PLANS. (FULL PERMIT IS NOT ISSUED UNTIL TXDOT PERMIT
ISSUED FOR WORK WITHIN STATE ROW .)
The Contractor shall take all necessary precautions to prevent silt and debris from leaving the immediate construction site
in accordance with the approved erosion control plan as well as the City of College Station Drainage Policy and Design
Criteria. If it is determined the prescribed erosion control measures are ineffective to retain all sediment onsite , it is the
contractors responsibility to implement measures that will meet City , State and Federal requirements . The Owner and/or
Contractor shall assure that all disturbed areas are sodden and establ ishment of vegetation occurs prior to removal of any
silt fencing or hay bales used for temporary erosion control. The Owner and /or Contractor shall also insure that any
disturbed vegetation be returned to its original condition , placement and state . The Owner and/or Contractor shall be
responsible for any damage to adjacent propert ies, city streets or infrastructure due to heavy machinery and/or equipment
as well as erosion , siltation or sedimentation resulting from the permitted work .
In accordance with Chapter 13 of the Code of Ordinances of the C ity of College Station , measures shall be taken to
insure that debris from construction , erosion, and sedimentation shall not be deposited in c ity streets , or existing drainage
facilities .
I hereby grant this permit for development of an area outside the special flood hazard area. All development shall be in
accordance with the plans and specifications submitted to and approved by the City Engineer in the development permit
appl ication for the above named project and all of the codes and ordinances of the City of College Station that apply.
Owner/~t/Contractor Date
DEVELOPMENT SERVICES
TRANSMITTAL LETTER
Name/Firm : Rabon Metcalf I RME Date: 912104
Add ress: P .O . Box 9253. College Station , TX 77842
Phone: (979) 219-4174 Fax: ___ ___....(""-'97;....;:;9""'-)-=69=0:;....-=.;03=2=9 ____ _
We a re t ransmitting the following for Development Serv ices to revi ew and comment: (Check all that apply.):
0 Master Development Plan w/ 0 Redlines
0 Preliminary Plat w/ 0 Redlines
0 Final Plat w/ 0 Redlines
0 FEMA ClOMA/ClOMR/lOMA/lOMR w/ 0 Redlines
0 S ite Plan w/ D Redlines
0 Grading Plan w/ 0 Redlines
0 landscape Plan w/ 0 Redlines
0 Irrigation Plan w/ 0 Redlines
0 Building Construction Documentsw/ 0 Redlines
INFRASTRUCTURE AND ENGINEERING DOCUMENTS
All infrastructure documents must be submitted as a complete set.
The following are included in t he complete set:
0 Waterline Construction Documents w/ 0 Redlines
0 Sewerline Construction Documents
0 Drainage Construction Documents
[gl Street Construction Documents
w/ 0 Redlines
w/ 0 Redlines
w/ 0 Redlines
0 Easement application with metes & bounds decsription
[gl Drainage letter or Report w/ D Redlines
0 Fire Flow Analysis w/ 0 Redlines
Special Instructions :
BTU -20' Private Maintenance Drive
0 Development Perm it App.
0 Conditio nal Use Permit
0 Rezonin g Application
0 Variance Request
0 Other -Please specify
--
--
[gl TxDOT Driveway Permit
0 TxDOT Utility Permit
0 Other -Please specify
EM AIL: r men gin eer @j u no .c o m
September 1, 2004
Alan P. Gibbs, P .E.
Development Engineer
City of College Station
1101 Texas Avenue South
College Station, TX 77842
RE: Drainage Letter for Bryan Texas Utilities (BTU)
West Loop 138 KV -20' Private Maintenance Drive
RME No. 158-0196
Dear Alan:
Please find the enclosed findings, calculations and attachments for the above referenced project's
drainage improvements. lbis drainage letter and the supporting design methods were performed
in accordance with the City of College Station's Drainage Design Policies and Standards.
Information used for the design, and the resulting calculations, of these drainage improvements
are as follows:
•!• X-1:
•!• X-2:
•!• X-3:
•!• A-1:
•!• A-2:
•!• B-1:
•!• B-2:
General
FEMA Map Panel;
Watershed-Structure 2 ;
Watershed -Structure 3;
Structure #2 -Hydrology;
Structure #3 -Hydrology;
Structure #2 -Hydraulics;
Structure #3 -Hydraulics;
lbis project consist of the construction of a 20' Wide Private Maintenance Drive for BTU's
West Loop 138 KV project. The private maintenance drive is located solely on 6 .79 acre and
70.734 acre tract (387, 3003 I 699, 259) and is located within the Bee Creek watershed .
This project site is not located or adjacent to any FEMA mapped floodplain
(see Exhibit X-1).
With the construction of this private maintenance drive, three (3 ) drainage structures will be
required. Drainage structure #I is the extension of an e x isting driveway culvert located at the
entrance of the Koppe Bridge Restaurant along FM 2158 (Wellborn Road). Drainage structures
#2 & #3 are located along the private drive at minor channel crossings (see Exhibits X-2 & X-3).
CDI-158-0 l 96-L03 Page -l
BTU -20' Private Maintenance Drive
Drainage Letter
Hydrology
Rabon Metcalf Engineering
September 1, 2004
Using the Rational Method for hydrology modeling, runoff values were determined for each
watershed. Results from the 2, 5, 10, 25, 50 & 100-year rainfall events for these drainage basins
are summarized below in Table #1 (see Exhibits A-1 & A-2).
Hydraulics
D.A.
X-2
X-3
TABLE#l-HYDROLOGYSUMMARY
(cfs)
3.8
18 .8
(cfs)
4 .7
23.9
(cfs)
5 .3
27.6
(cfs)
6 .1
31.8
(cfs)
6 .9
36.4
(cfs)
7.2
38.2
Using the hydrologic data, flows were conveyed through the appropriate drainage structure and
the drainage pipe sized accordingly (see Exhibit B-1 & B-2). Selected hydraulic data for each
drainage structure is summarized below in Table #2.
TABLE#2-HYDRAULICSUMMARY
25-Year 100-Year
e octty e octty
Structure Type & Siz (cfs) (fps) Control (cfs) (fps) Control
2 18" CMP 6.1 5.1 Outlet 7 .2 5.5 Outlet
3 2-24" CMP 15.9 5.1 Outlet 19.l 6.1 Outlet
As mentioned previously, the attached engineering calculations are issued for the stated drainage
improvements and are issued by me and are applicable to this project. Please call should you
have any questions or require assistance.
Sincerely,
Rabon A. Metcalf, P.
rmengineer@verizon.n
CDI-158-0 l 96-L03 Page-2
EX
APPROXIMATE SCALE
500EEE3~==~E"3=::C::~E?3=::~0::::::::::::::::::::::::::::::J500FEET
llATIDllAL FLOOD lllSURAllCE PIOHAM
FLOOD INSURANCE RATE MAP
BRAZOS COUNTY,
TEXAS AND
INCORPORATED AREAS
PANEL 182 OF 250
llll MAP INOIX 'O" ll'ANILI NOT ~llUNTIO)
1!!11!111 l.!m 1!llll!
•110011 0111 e
UN~CORPORATEO AllUI """ 0112
•• Ill UMr: Tiit MAr IUMIH *-k41w ._.. lie ai1t1
•• pllcll1 .., 9'•111; .. COllMUllITT IUl .. U ......
........... ~ ........ ., .................. Cf -· MAP NUMBER
48041CDl82 C
EFFECTIVE DATE:
JULY 2, 1992
Thia la 1n otndal copy of a portion of the above ,.,.,.need ftood map . It was extract1d
ualng F-MIT V1ralon 1.0 . Thia map doH nol reftact change• or am1ndm1nll which
may have bHn made aubaequent lo Iha date on Iha UUe block . Futher lnfOrmati on
about National Flood lnaurance Program ftood hazard maps It 1v1ll1ble at
www.lema . v/m lt/lld.
PDF Crtlll D1te: 7fl/20CM (Cflltld et tcllt and tvP• A)
::2 /, I I I ~~l ~ r ~u..N I U10 ::it: L ......, ( -......... _,. I J --( / ) / o_ ow I ::J w Cl'.'. I . I ::J ; ~~() II w ::J 00 f--Cl'.'. / LO <( p. j //'~"-----..j$~U1 I I II '-) I I / ~ ) -..._ ---__/ I / ~ ----_./ /----/ '-I "'-'-.. j "'-__,/ --.. / " /-/ ~-/ I I ~ i--,,.., ~ / ' ~ \I \" )~ \/ o r".. I / "-, ~ I\\\: z '-"" I \ *~ \\_'-' f--I \ '-' w /' -w x ", l "-Oi "" ~ .,_"<t'_<C_o ___ I_::2....,. '-... /\ ~ .e a::: 0 (.) <( '"'~ O:::a::: ,,-.--..... l"1 x II .. ~c.o: >-"-ai~ m "'---~ "\""-, I /' / // f "' ~ -;:. oo .. ~rn .. w w .. _J f-W<( <(~ <C::::!U O:::I 0 LL V1 0 (.) ///) N w ()'.'.'.: (./) ::J (./) <( 1-w x U-W ::J I-I-()'.'.'.: _J I-I-z-(./) ::J 0 I Ul I-<( <( c.o 0 x I-Ol 0 w w (./) I I I-W CXJ L{) 2Q z C) w <( :=J 0 I->-_J z <( ()'.'.'.: 0 w smu ::2 Cl'.'. .... @"' ~ ~ en ~ N ,.._ ..., g 8ai" IJ'1~ ::::J IN-Nwe o"'+ c:i"""'~ .,,9,), z x ·ll '°o-~ o~ c: ,-..O'IC" ~ ~ <Df:="ij\ ~CD_.. ~ ~~~fi em~ z 23 ~c::vi§ ~e 0 E---~w 1~ i:Q ~ C!J ~<.:l .. w I I < z1-;j_U....1 ~~ vi :::i Ex-' ~~~ ~ow o.1tl
_)
, __ ./-_,1
)
RABON ~
METCALF~
ENGINEERING
POST OFFlCE BOX 9253
COli.EGE STATION, TEXAS 77842
EMAIL: rmengineerOjuno.com
OFFlCE -(979) 690-0329
FAX -(979) 690-0329
CELL -(979) 219-4174
"" ! .......,
) \
L. "
(
(
/ \
( " ) )
/
,,..1
( "' /
(
\
I
WATERSHED -STRUCTURE 3
BRYAN TEXAS UTILITIES
COLLEGE STATION, TEXAS
RME NO. 158-0196
J
)
)
I
DATE: 07 /13/04 SHEET NO .
FILE: 0196X3RA
SCALE : 1''=300'
DRAWN BY : RCH x-3
CHK BY : RAM
\
l
.
RATI ONAL METHOD: D rainage Structure #2
GENERAL I NFORMATION
Description : W aters hed U ps tream of Drai nage Struct u re #2
Drainage Area = 2 .58 acres
Coefficient of Runoff (Cwro} = 0.36
TIME OF CO NCENTRATION CT cl
G IVEN
Maximum Travel Distan ce (D1} =
Velocity of Runoff (VcRee0 =
Maximum Travel Distance (D2} =
Velocity of Runoff (VcHANNEd =
Maximum T ravel Distance (D3 } =
Velocity of Runoff (V3 } =
0 ft
ft 3.50 lsec
0 ft
2 .2 5 ft/sec
705 ft
ft 0.50 fsec
**NOTE: M inimum Tc allowed = 10 min.
2 Y EAR F RE QUENCY. RATE OF DISCHARGE (Q)
Coefficient ( e} =
Coefficient (b} =
Coefficien t (d} =
0.806
65
8
5 Y EAR F REQU ENCY . RA TE OF DISC HARGE (Q)
Coefficient (e} = 0.785
Coefficient (b} = 76
Coefficie nt (d } = 8.5
10 Y EAR FREQU ENCY. RATE OF DISCHARGE (Q)
Coefficient ( e} =
Coefficient (b} =
Coefficient (d} =
0 .763
80
8.5
25 YEAR FREQUEN CY. RATE O F DISCHARGE (Q )
Coefficient (e} = 0.754
Coefficie nt (b} =
Coefficie nt ( d} =
89
8 .5
50 YEAR FREQUENCY. RATE OF DISCHARGE (Q)
Coefficient (e} = 0 .745
Coefficient (b} = 98
Coefficient (d} = 8.5
100 Y EAR FR EQUENCY. RATE OF DISCHARGE (Q)
Coefficient (e} = 0.73
Coefficient (b} = 96
Coefficient (d} = 8
Bryan Te xas Utilities
20' Private Maintenance Drive
158-0196 Rational Method
RESULT
Tc1 =
Tc2 =
Tc3 =
Tc=
Rainfall Intensity (1 2) =
Rainfa ll Intensity (1 5) =
gg=
0 .0 min.
0 .0 min.
23.5 min.
23 .5 min .
3.8 cfs
5.003 in/hr
4.7 cfs
Rainfall Intensity (1 10) = 5.684 in/hr -----
Q10 = 5.3 cfs
Rainfall Intens ity (12s} = ---Q =
Rainfall Intensity (1 50) =
o.=
Rainfall Intensity (1 100) =
Q oo=
7.411 in/hr
6.9 cfs
7.736 in/hr
7 .2 cfs
A-1
• RATIONAL METHOD: Drainage Structure #3
GENERAL INFORMATION
Description : Watershed Upstream of Drainage Structure #3
Drainage Area= 22.45 acres
Coefficient of Runoff (Cwm) = 0 .38
TIME OF CONCENTRATION (T cl
GIVEN
Maximum Travel Distance (D 1) =
Velocity of Runoff (V cREEtU =
Maximum Travel Distance (D 2) =
Velocity of Runoff (VcHANNEd =
Maximum Travel Distance (D3 ) =
Velocity of Runoff (V3) =
0 ft
3.50 ft/$«;
940 ft
1.40 ft/sec
1445 ft
0 .50 ft/$«;
**NOTE: Minimum Tc allowed= 10 min .
2 YEAR FREQUENCY. RATE OF DISCHARGE (Q)
Coefficient (e) = 0 .806
Coefficient (b) = 65
Coefficient ( d) = 8
5 YEAR FREQUENCY. RA TE OF DISCHARGE (Q)
Coefficient (e) = 0.785
Coefficient (b) = 76
Coefficient (d) = 8 .5
10 YEAR FREQUENCY, RATE OF DISCHARGE (Q)
Coefficient (e) = 0 .763
Coefficient (b) = 80
Coefficient (d) = 8 .5
25 YEAR FREQUENCY. RATE OF DISCHARGE (Q)
Coefficient ( e) =
Coefficient (b) =
Coefficient (d) =
0.754
89
8.5
50 YEAR FREQUENCY. RA TE OF DISCHARGE (Q)
Coefficient ( e) =
Coefficient (b) =
Coefficient (d) =
0 .745
98
8 .5
100 YEAR FREQUENCY. RATE OF DISCHARGE (Q)
RESULT
Tc1 =
Tc2 =
Tc3 =
Tc=
Rainfall Intensity (1 2 ) =
a2=
Rainfall Intensity (1 5) =
as=
Rainfall Intensity (1 10) =
0 .0 min .
11 .2 min .
48.2 min.
59.4 min .
18.8 cfs
23.9 cfs
27.6 cfs
Rainfall Intensity (1 25 ) = 3 .701 in/hr ---------Q 25 = 31.8 cfs
Rainfall Intensity (1 50 ) = 4 .233 in/hr ----g.= 36A cfs
Coefficient (e) = 0.73 Rainfall Intensity (1 100) = 4 .442 in/hr
Coefficient (b) = 96 ._Q"""1,..oo,_= _________ 38_.2_cfs __
Coefficient ( d) = 8
Bryan Texas Utilities
20' Private Maintenance Drive
158-0196 Rational Method A-2
output.lis
TEXAS HYDRAULIC SYSTEM, CULVERT (ver. 1.2. Feb/2002)
wed Sep 01 16:59:01 2004
CULVERT HYDRAULIC COMPUTATIONS
CULVERT NAME:
PROJECT NAME:
X2
BTU: 20' Private Driv
158-0196
Input units: English
output units: English
PROJECT CONTROL :
COUNTY:
DESCRIPTION:
Brazos county
Drainage Study
ANALYZE SINGLE OPENING CULVERT
MATERIAL: ALUMINIUM
SHAPE: CORRUGATED CIRCULAR PIPE.
ENTRANCE: THIN
PROFILE: STRAIGHT CULVERT
FREQUENCY: 2 YR DISCHARGE: 3 .80
FREQUENCY: 5 YS DISCHARGE: 4.70
FREQUENCY: 10 YR DISCHARGE: 5.30
FREQUENCY: 25 YR DISCHARGE: 6 .10
FREQUENCY: 50 YR DISCHARGE: 6.90
FREQUENCY: 100 YR DISCHARGE: 7.20
TAILWATER ELEVATION (computed).
n value: 0.0150 Ke value: 0.9000
CULVERT DIAM. = 1.50 ft BARRELS= 1
cf s
cf s
cf s
cf s
cf s
cf s
INLET station:
OUTLET station:
0.00
45.00
elevation:
elevation:
cross section profile (XY coordinates) ft x y x
359.00 287.27 422 .00
Road profile (XY coordinates) ft x y x
310.00 288.90 425.00
CULVERT OUTPUT RUN NO => 1
y
285.73 ft
285.39 ft
285.67
y
288.40
TAILWATER ELEVATION: 286.01 ft (computed).
ANALYSIS for discharge frequency of : 2 YR
x
454.00
x
Barls. Qpb Rise Span Length Max.HW calc.HW HW control
elev elev
cfs ft ft ft ft ft ft
1 3.80 1.50 0.00 45.00 0.00 286.89 1.16 Inlet
Inlet control depth
outlet control depth =
1.16 ft
1. 31 ft
Page 1
y
287.02
y
veloc. out.depth
ft/s ft
4.43 0.73
Normal depth 0.73 ft
critical depth= 0.75 ft
Road top width => 0.00 ft.
computed weir coefficient =>
No discharge over the road.
CULVERT OUTPUT
output.lis
culvert slope =
critical slope =
Pavement type => gravel
3.00.
RUN NO => 2
TAILWATER ELEVATION: 286.04 ft (computed).
ANALYSIS for discharge frequency of : 5 Y5
Barls. Qpb Rise Span Length Max.HW calc.HW HW
elev elev
cf s ft ft ft ft ft ft
0.00756
0.00713
control
1 4.70 1.50 0.00 45.00 0.00 287.06 1.33 Inlet
Inlet control depth =
outlet control depth
Normal depth = 0.83 ft
critical depth = 0.83 ft
Road top width => 0.00 ft.
computed weir coefficient=>
No discharge over the road.
CULVERT OUTPUT
1. 33 ft
1.48 ft
culvert slope =
critical slope =
Pavement type => gravel
3.00.
RUN NO => 3
TAILWATER ELEVATION: 286.05 ft (computed).
ANALYSIS for discharge frequency of : 10 YR
Barls. Qpb Rise Span Length Max.HW calc.Hw HW
elev elev
cfs ft ft ft ft ft ft
0.00756
0.00753
control
1 5.30 1.50 0.00 45.00 0.00 287.31 1.58 Outlet
Inlet control depth
outlet control depth =
Normal depth = 0.90 ft
critical depth = 0.89 ft
Road top width => 0.00 ft .
computed weir coefficient =>
No discharge over the road.
CULVERT OUTPUT
1.45 ft
1. 58 ft
culvert slope =
Critical slope =
Pavement type => gravel
3.00.
RUN NO => 4
TAILWATER ELEVATION: 286 .07 ft (computed).
ANALYSIS for discharge frequency of : 25 YR
Barls. Qpb Rise Span Length Max.HW calc.Hw HW
elev elev
cf s ft ft ft ft ft ft
Page 2
0.00756
0.00785
control
veloc. out .depth
ft/s ft
4.67 0.83
veloc. out.depth
ft/s ft
4.87 0 .89
veloc . out.depth
ft/s ft
output.lis
1 6.10 1.50 0.00 45.00 0.00 287.44 1.71 outlet
Inlet control depth =
outlet control depth =
Normal depth = 0.99 ft
critical depth = 0.95 ft
Road top width => 0.00 ft.
computed weir coefficient =>
No discharge over the road.
CULVERT OUTPUT
1. 62 ft
1. 71 ft
culvert slope =
critical slope =
Pavement type => gravel
3.00.
RUN NO => 5
TAILWATER ELEVATION: 286.09 ft (computed).
ANALYSIS for discharge frequency of : 50 YR
Barls. Qpb Rise Span Length Max.HW calc.Hw HW
elev elev
cf s ft ft ft ft ft ft
0.00756
0.00834
control
1 6.90 1.50 0.00 45.00 0.00 287.57 1.84 outlet
Inlet control depth
outlet control depth
Normal depth 1.08 ft
critical depth = 1.02 ft
Road top width => 0.00 ft.
computed weir coefficient =>
No discharge over the road.
CULVERT OUTPUT
1. 79 ft
1. 84 ft
culvert slope =
critical slope =
Pavement type => gravel
3.00.
RUN NO => 6
TAILWATER ELEVATION: 286.10 ft (computed).
ANALYSIS for discharge frequency of : 100 YR
sarls. Qpb Rise Span Length Max.HW calc.Hw HW
elev elev
cf s ft ft ft ft ft ft
0.00756
0.00892
control
1 7.20 1.50 0.00 45.00 0.00 287.61 1.88 outlet
Inlet control depth =
outlet control depth
Normal depth 1.12 ft
critical depth 1.04 ft
Road top width => 0.00 ft.
computed weir coefficient=>
No discharge over the road.
1.86 ft
1.88 ft
culvert slope =
critical slope =
Pavement type => gravel
3.00.
0.00756
0.00917
5.14 0.95
veloc. out.depth
ft/s ft
5.41 1.02
veloc. out.depth
ft/s ft
5.51 1.04
------------------------------------------------------------------------------
RUNING MESSAGES LIST:
Page 3
output.lis
*Computation: Hydraulic jump occurs at culvert outlet.
NORMAL TERMINATION OF THYSYS, CULVERT.
Page 4
. .
output. l is
TEXAS HYDRAULIC SYSTEM, CULVERT (ver. 1.2. Feb/2002)
wed Sep 01 16:59:13 2004
CULVERT HYDRAULIC COMPUTATIONS
CULVERT NAME:
PROJECT NAME:
X3
BTU: 20' Private Driv
158-0196
Input Units: English
Output units: English
PROJECT CONTROL:
COUNTY:
DESCRIPTION:
Brazos county
Drainage Study
ANALYZE MULTIPLE OPENING
MATERIAL: ALUMINIUM
CULVERT
SHAPE: CORRUGATED CIRCULAR PIPE.
ENTRANCE: THIN
PROFILE: STRAIGHT CULVERT
FREQUENCY: 2 YR
FREQUENCY: 5 YR
FREQUENCY: 10 YR
FREQUENCY: 25 YR
FREQUENCY: 50 YR
FREQUENCY: 100 YR
DISCHARGE:
DISCHARGE:
DISCHARGE:
DISCHARGE:
DISCHARGE:
DISCHARGE:
TAILWATER ELEVATION (computed).
18.80 cfs
23.90 cfs
27.60 cfs
31.80 cfs
36.40 cfs
38.20 cfs
n value: 0.0170 Ke value: 0.9000
CULVERT DIAM. = 2.00 ft BARRELS = 2
INLET station:
OUTLET station:
0.00
30.00
elevation:
elevation:
cross section profile (XY coordinates) ft
x y x
817.00 284.83 839.00
867.00 285.04
Road profile (XY Coordinates) ft
x y x
805 .00 285.62 825.00
865.00 285.45 885.00
CULVERT OUTPUT RUN NO => 1
y
281.58 ft
281.38 ft
281.45
y
285.48
285.57
TAILWATER ELEVATION: 282.58 ft (computed).
ANALYSIS for discharge frequency of : 2 YR
x
844.00
x
845.00
905.00
Barls. Qpb Rise span Length Max.HW calc.HW HW control
elev elev
cfs ft ft ft ft ft ft
2 9.40 2.00 0.00 30.00 0.00 283.45 1.87 Outlet
Inlet control depth = 1. 75 ft
Page 1
y
281. 51
y
285.42
285.78
veloc. out.depth
ft/s ft
4.79 1.20
. .
outlet control depth
Normal depth 1.19 ft
critical depth 1.10 ft
Road top width => 0 .00 ft.
computed Weir coefficient=>
No discharge over the road.
CULVERT OUTPUT
1.87 ft
output.lis
culvert slope =
critical slope =
Pavement type => gravel
3.00.
RUN NO => 2
TAILWATER ELEVATION: 282.71 ft (computed).
ANALYSIS for discharge frequency of : 5 YR
Barls. Qpb Rise span Length Max.HW calc.HW HW
elev elev
cfs ft ft ft ft ft ft
0.00667
0.00872
control
2 11.95 2.00 0.00 30.00 0.00 283.75 2.17 outlet
Inlet control depth =
outlet control depth =
Normal depth = 1.41 ft
critical depth 1.24 ft
Road top width => 0.00 ft.
computed weir coefficient =>
No discharge over the road.
CULVERT OUTPUT
2.08 ft
2.17 ft
culvert slope =
critical slope =
Pavement type => gravel
3.00.
RUN NO => 3
TAILWATER ELEVATION: 282.79 ft (computed).
ANALYSIS for discharge frequency of : 10 YR
Barls. Qpb Rise span Length Max.HW calc.Hw HW
elev elev
cfs ft ft ft ft ft ft
0.00667
0.00953
Control
2 13.80 2 .00 0.00 30.00 0.00 283.96 2.38 outlet
Inlet control depth =
outlet control depth
Normal depth = 1.60 ft
critical depth = 1.34 ft
Road top width => 0.00 ft.
Computed weir coefficient =>
No discharge over the road.
CULVERT OUTPUT
2.34 ft
2.38 ft
culvert slope =
critical slope =
Pavement type => gravel
3.00.
RUN NO => 4
TAILWATER ELEVATION: 282.88 ft (computed).
ANALYSIS for discharge frequency of : 25 YR
0.00667
0.01026
veloc. out.depth
ft/s ft
5.40 1.33
veloc. out.depth
ft/s ft
5.83 1.41
Barls. Qpb Rise span Length Max.HW calc.HW HW Control veloc. out.depth
Page 2
. ..
output.lis
elev elev
cf s ft ft ft ft ft ft
2 15.90 2.00 0.00 30 .00 0.00 284.20 2.62 outlet
Inlet control depth =
outlet control depth =
2.66 ft
2.62 ft
Normal depth = 2.00 ft culvert slope = 0.00667
critical depth = 1.44 ft critical slope = 0.01126
Road top width => 0.00 ft. Pavement type => gravel
computed weir coefficient => 3.00.
No discharge over the road.
CULVERT OUTPUT RUN NO => 5
TAILWATER ELEVATION: 282.96 ft (computed).
ANALYSIS for discharge frequency of : 50 YR
Barls. Qpb Rise Span Length Max.HW calc.HW HW Control
elev elev
cfs ft ft ft ft ft ft
2 18.20 2.00 0.00 30.00 0.00 284.49 2.91 outlet
Inlet control depth =
outlet control depth =
Normal depth = 2.00 ft
critical depth= 1.54 ft
Road top width => 0.00 ft.
computed weir coefficient =>
No discharge over the road .
CULVERT OUTPUT
3.07 ft
2.91 ft
culvert slope =
critical slope =
Pavement type => gravel
3.00.
RUN NO => 6
TAILWATER ELEVATION: 283.00 ft (computed).
ANALYSIS for discharge frequency of : 100 YR
0.00667
0.01260
Barls. Qpb Rise span Length Max.HW calc.HW HW control
elev elev
cf s ft ft ft ft ft ft
2 19.10 2.00 0.00 30.00 0.00 284.62 3.04 outlet
Inlet control depth =
outlet control depth =
Normal depth = 2.00 ft
critical depth = 1.57 ft
Road top width => 0.00 ft.
computed weir coefficient =>
No discharge over the road.
3.24 ft
3.04 ft
culvert slope =
critical slope =
Pavement type => gravel
3.00.
Page 3
0.00667
0.01322
ft/s f t
5.06 2 .00
veloc. out.depth
ft/s ft
5.79 2.00
Veloc. Out.depth
ft/s ft
6.08 2.00
. .
output.lis
RUNING MESSAGES LIST:
NORMAL TERMINATION OF THYSYS, CULVERT.
Page 4
CA '-~...\
~
DEVELOPMENT PERMIT
FOR OFFICE us~ ,O~L y
Case No. vq ~ 'ttJ "if,
Date Submitted 1 -Lq -{)
MINIMUM SUBMITTAL REQUIREMENTS
[8J $200.00 development permit fee .
[8J Drainage and erosion control plan , with supporting Drainage Report two (2) copies each
D Notice of Intent (N .0.1.) if disturbed area is greater than 5 acres
Date of *Required Preapplication Conference: __________________ _
*(Required for areas of special flood hazard)
LEGAL DESCRIPTION Called 6.79 Acre & 70.734 Acre Tracts (Vol. 387/3003, Pg. 699/259)
APPLICANrS INFORMATION (Primary Contact for the Project):
Name ____ ~R~a=bo~n~A~·~M~et=c=a=lf~·~P=.E=·-----E-Mail __ rm ........ e.._n_g_i __ nee......_.r .... @ ... v .... e ..... r .... iz..,..o..,..n ...... n .... e ..... t __
Street Address ----------------"-P""".O=·:....::B"'"'o=x--9=2=5=3 ___________ _
City College Station State _____ T __ e=x=a-.s___ Zip Code _77_84_2 __ _
Phone Number __ _.....(9 ...... 7_9 .... ) ..... 21_9.._-4_1 ..... 7_4 ____ _ Fax Number _____ (.__9 ...... 79__,)...._.6"""'9-.0_.-0--3=29"-----
PROPERTY OWNER'S INFORMATION:
Name Edsel G. Jones E-Mail -----__...;;;;~---=--.-..,;;...;~-------~ -------------
Street Address --------------"""3 __ 1 __ o __ u __ n __ iv;..;;e-.rs=i=ty"-=D..;..;ri--v=e-=E=a=s--t --------
City ___ C_o_ll_eg_e_S_ta_t_io_n ____ State ___ T ..... e_x ...... as ____ _ Zip Code ___ .... 77.._.8_.4--0 __ _
Fax Number -------------Phone Number ___ __...(9-..;7.__9..._) ..... 6 ...... 93 ..... -....... 15-..;3 .... 0.___ __ _
ARCHITECT OR ENGINEER'S INFORMATION:
Name ____ _.R ..... a~b_o~n-A ........... M---...et~c--a~lf_._P--.E~·-----E-Mail --------------
Street Address -------------------------------City ____________ State _______ _ Zip Code--------
Phone Number Fax Number --------------
App Ii cation is hereby made for the following development specific site/waterway alterations:
Construction of 20' Wide Private Maintenance Drive for construction and upkeep of BTU West Loop
138 KV power line.
ACKNOWLEDGMENTS:
I, Rabon A. Metcalf P. • , design engineer/owner, hereby acknowledge or affirm that:
6/13/03
lusions contained in the above plans and supporting documents comply with the
e City of College Station , Texas City Code, Chapter 13 and its associated Drainage
rds .
1 of 2
As a condition of approval of this permit application, I agree to construct the improvements proposed in this
application according to these documents and the requirements of Chapter 13 of the College Station City
Code
Contractor
CERTIFICATIONS:
A. I, N/A, certify that any nonresidential structure on or proposed to be on this site as part of this application
is designated to prevent damage to the structure or its contents as a result of flooding from the 100-
year storm.
Engineer Date
B. I, NIA, certify that the finished floor elevation of the lowest floor, including any basement, of any
residential structure, proposed as part of this application is at or above the base flood elevation
established in the latest Federal Insurance Administration Flood Hazard Study and maps, as amended .
Engineer
C. I, Rabon A. Metcalf
diminish the flood-
such alterations or
C er 13
D.
Date
.E., certify that the alterations or development covered by this permit shall not
rrying capacity of the waterway adjoining or crossing this permitted site and that
evelopment are consistent with requirements of the City of College Station City
ncerning encroachments of floodways and of floodways fringes .
Date
Conditions or comments as part of approval: ----------------------
In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be
taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets,
or existing drainage facilities. All development shall be in accordance with the plans and specifications
submitted to and approved by the City Engineer for the above named project. All of the applicable codes and
ordinances of the City of College Station shall apply.
6/13/03 2 of 2
DEVELOPMENT SERVICES
TRANSMITTAL LETTER
Name/Firm: Rabon Metcalf I RME Date: 7/19/04
Address: P.O. Box 9253, College Station. TX 77842
Phone: (979) 219-417 4 Fax: ___ __.(..;:;..97;;...;;9;;..,_)~6-=-90;::;...-=03=2=9 ____ _
We are transmitting the following for Development Services to review and comment: (Check all that apply .):
D Master Development Plan w/ D Redlines
D Preliminary Plat w/ D Redlines
D Final Plat w/ D Redlines
D FEMA ClOMA/ClOMR/lOMA/lOMR w/ D Redlines
D Site Plan w/ D Redlines
D Grading Plan
D landscape Plan
D Irrigation Plan
w/ 0 Redlines
w/ D Redlines
w/ D Redlines
D Building Construction Documentsw/ 0 Redlines
INFRASTRUCTURE AND ENGINEERING DOCUMENTS
All infrastructure documents must be submitted as a complete set
The following are included in the complete set:
0 Waterline Construction Documents w/ 0 Redlines
D Sewerline Construction Documents
D Drainage Construction Documents
[8J Street Construction Documents
w/ 0 Redlines
w/ 0 Redlines
w/ D Redlines
D Easement application with metes & bounds decsription
D Drainage letter or Report w/ D Redlines
0 Fire Flow Analysis w/ D Redlines
Special Instructions:
BTU -20' Private Maintenance Drive
D Development Permit App .
D Conditional Use Permit
D Rezoning Application
D Variance Request
D Other -Please specify
[8J TxDOT Driveway Permit
D TxDOT Utility Permit
D Other -Please specify
[ Alan Gibbs -BTU Driveway
From:
To:
Date:
Subject:
Alan ,
Spencer Thompson
Alan Gibbs
8/20/2004 3:25 :24 PM
BTU Driveway
Rabon has submitted a driveway permit for a easement/ utility maintenance drive on Wellborn Road . The
spacing does not meet City or TxDOT spacing requirements.
The DE can make judgement calls in such case per the UDO. Justification for the drive not meeting the
required spacing will have to go in a cover letter to TxDOT.
Rabon would like to meet. If you can find a minute I'll set up a meeting.
thx
st
Spencer G . Thompson , Jr.
Engineering Services
City of College Station
PO Box 9960
College Station, TX 77842
Ph . 979 .764.3570 Fx . 979 .764 .3496
www .cstx .gov
CC: Rabon Metcalf
-Pr-~ c:; r~~
~UDO
-V~~~
~ Cvti L{~
--JottJ\ ~)
Page 1 I