Loading...
HomeMy WebLinkAbout31 DP Lincoln Comm Center 04-11 1000 Eleanor.... ~ R ABON M ETCALF ENGINEERRilN:G::-:~~::::::====~~::::: (979 )690 -03 29 _H o m e D~-3 q POSfOFFICEBOX 92 53 =-(9 79)69 0-03 29 -FAX OJ/ COLLEGE SfATION , TEXAS77842 (979 )2 19-4174 -C ELL 2. .. J lD • ' February 16, 2004 Carol Cotter, E.I.T. Graduate Engineer EM.AIL r men gin eer @ju no .c o m City of College Station 1101 Texas A venue South College Station, TX 77842 RE: Lincoln Community Center -Expansion & Multipurpose Pavilion Drainage Letter RME No. 138-0181 Dear Carol: Please find the enclosed findings, calculations and attachments for the above referenced project's drainage facilities and improvements. This drainage letter and the supporting design methods were performed in accordance with the City of College Station's Drainage Design Policies and Standards. Information used for the design, and the resulting calculations, of these drainage improvements are as follows: •!• A-1: •!• A-2: •!• A-3: •!• A-4: •!• B-1: •!• B-2: General Bee Creek Watershed Map; FEMA Map Panel; Proposed Drainage Area Map; Grading, Drainage & Paving Plan Pre-Development Storm Sewer Hydraulics; Post-Development Storm Sewer Hydraulics; The project site is at 1000 Eleanor Street and is located within the watershed of Bee Creek (see Exhibit A-1). Additionally, the improvements for this project is not located, but the property of the Community Center itself does contain FEMA mapped floodplain (see Exhibit A-2). In general, undeveloped areas on this property are vacant, covered by native weeds and grasses, and have minimal tree coverage. Developed areas consist of the current Lincoln Center and associated parking areas . CDl-138-0181-LOl Page - 1 Lincoln Community Center Expansion & Multipurpose Pavilion Drainage Letter Hydrology Rabon Metcalf Engineering February 16, 2004 Since the policy of the City is to encourage the rapid conveyance of stormwater through and out of the City within a primary system, and being that this project's improvements are located · approximately one-hundred feet (100') upstream of a designated primary system, no detention will be accommodated for the increased runoff from impervious cover. Hydraulics With the construction of the parking lot expansion an existing curb inlet on Eleanor Street will be converted into a grate inlet at sag. Also, the overflow ditch for the 4'x3' box culvert will become the drive lane of the parking lot improvements (see Exhibits A-3 & A-4). Therefore, a hydraulic analysis of the existing storm sewer system was conducted so that the proposed grate inlet would function with the existing system equally as well or better (see Exhibits B-1 & B-2). Both systems were evaluated with a design frequency of the 10-year rainfall event and analyzed during the 100-year rainfall event. At existing conditions, the curb inlet was determined to have a capacity of 10.327 cfs which exceeded the runoff conveyed to it of 9 .110 cfs. The ponding depth during this event is 0.46 feet. For the proposed conditions, the curb inlet will be modified to an area grate inlet. A Neenah Foundary grate Model 1878-BllG was found to have sufficient capacity. With this condition the capacity of the inlet would be increased to 16.044 cfs and a ponding depth reduced to 0.343 feet. Currently, with existing conditions, when the curb inlets capacity is exceed, runoff overflows into a earthen ditch that conveys water to the primary creek system. With the construction of the parking lot driveway entrance, the cross-section of the driveway was design to function as a V - shaped weir. The centerline drain was set at an elevation of 309.75 . The existing low point of the curb is at 309.83. As mentioned previously, the attached engineering calculations are issued for the stated drainage improvements and are issued by me and are applicable to this project. Please call should you have any questions or require assistance. Sincerely, Rabon A. Metcalf, P. rmengineer@juno.com CD 1-138-0181-LO 1 Page-2 .. / / , r '"' I~ I-' 15 lu I I I I ~ / ill I I QJ ~ I /1 TEXAS AV I I ·--\AL) \_.,, ~ , WELLBORN Ro. I >-4 3:: , / I OARTMOIJTH I ~ I ' ""' A· ' )> ZONE ' ~ 500 APPROXIMATE SCALE 0 IATIOIAL FLOOD llSUIAICE PIOHAI FLOOD INSURANCE RA TE MAP BRAZOS COUNTY, TEXAS AND INCORPORATED AREAS PANEL 144 OF 250 CHI MAP INDl.JC ,011 •AN•L.a NOT •lltNTIOI llllHB ML lllf!!! 410011 81 .. 480011 0144 ldct11-lllo11»•ut111•---..... -....... "'f ,. • .., '°' COMllWlm WMIEll .-._ ._.. ...... i-r., ............ ~ -.. MAP NUMBER 48041C0144 C EFFECTIVE DATE: JULY 2, 1992 This Is .,., offlcJal copy of • portion of the above referenced flood map. H was extracted using F-MIT Version 1.0. This map does not reflect chenges or amendments v.tilch may have been made aubsequent to the date on the title block. Futher lnfonnatlon ---------------':--'--'----J.'-L--_;,.._....,.........,~~--------------L.-L.----1 •bout N•tionel Flood lmunlnce Progrem flood haZllfd maps la evaileble at www.feme . lmllltld. . . ~ '· ... WinStorm (STORM DRAIN DESIGN) PROJECT NAME : Lincoln Center JOB NUMBER 138-0181 stmOutput Version 3.05, Jan. 25, 2002 Run @ 2/16/2004 7:42:07 AM PROJECT DESCRIPTION : Storm Sewer System -Existing Conditions DESIGN FREQUENCY ANALYSYS FREQUENCY MEASUREMENT UNITS: 10 Years 100 Years ENGLISH OUTPUT FOR DESIGN FREQUENCY of: 10 Years =========================================== Runoff Computation for Design Frequency. ============================================================================= ID C Value A-1 0.9 A-2 0.45 A-3 0.45 A-4 0.9 A-5 0.5 A-6 0.45 Area (acre) 0.20 3.74 3.98 0.26 1. 75 6.29 Tc (min) 10.00 20.00 25.00 10.00 25.00 25.00 Tc Used (min) 10.00 20.00 25.00 10.00 25.00 25.00 Intensity (in/hr) 8.63 6.21 5.49 8.63 5.49 5.49 Supply Q (cfs) 0.000 0.000 0.000 0.000 0.000 0.000 Total Q (cfs) 1.554 10.450 9.831 2.020 4.803 15.536 On Grade Inlet Configuration Data =============================================================================== Inlet ID A-2 A-4 A-5 Inlet Type Curb Curb Curb Inlet Slopes Gutter Length Long Trans n Depr. (ft) (%) (%) 5.00 6.37 5.00 0.36 10.00 27.00 2.00 0.014 2.00 0.014 2.00 0.014 (ft) 0.33 0.33 0.33 On Grade Inlets Conmputation Data. Grate Width Type (ft) n/a n/a n/a n/a n/a n/a Pond Width Allowed (ft) 12.00 12.00 12.00 Critic Elev. (ft) 309.10 310.50 310.50 ================================================================================= Inlet ID A-2 A-4 A-5 Inlet Type Curb Curb Curb Total Q (cfs) 10.450 2.020 4.803 Intercept Capacity (cfs) 2.976 1. 939 2.744 Q Bypass Allow Actual (cfs) (cfs) 0.000 0.250 0.250 7.474 0.082 2.058 Page 1 To Inlet Required ID Length A-1 A-1 A-3 (ft) 29.43 6.01 26.63 Actual Length (ft) 5.00 5.00 10.00 Ponded Width (ft) 11.70 10.80 6.65 stmOutput Sag Inlets Configuration Data. ================================================================================= = Inlet Inlet Length/ Grate Left-Slope Long Trans ID Type Perim. Area A-1 A-3 A-6 (ft) (sf) ( % ) ( % ) Curb 10.00 Curb 8.00 Curb 10.00 n/a 0.60 2.00 n/a 38.30 2.00 n/a 2.70 2.00 Sag Inlets Computation Data. Right-Slope Long Trans ( % ) ( % ) Gutter n DeprW (ft) 0.30 2.00 0.014 0.50 2.00 0.014 0.16 2.00 0.014 1. 50 1. 50 1. 50 Depth Allowed (ft) 0.50 0.50 0.50 Critic Elev. (ft) 309.00 310.40 310.80 ================================================================================ Inlet Inlet ID Type A-1 A-3 A-6 Curb Curb Curb Length Grate Perim Area (ft) (ft) (sf) 10.00 8.00 10.00 n/a n/a n/a n/a n/a n/a Total Q Inlet Capacity (cfs) (cfs) 9.1 10 11.889 15.536 10.327 10.749 13.436 Cumulative Junction Discharge Computations Total Head (ft) 0.460 0.556 0.584 Ponded Width Left Right (ft) (ft) 16.95 6.75 12.25 6.4 0 15.25 20.85 ================================================================================= Node Node Weighted Cumulat. Cumulat. Intens. User Additional Total I. D. Type C-Value Dr.Area Tc Supply Q Q in Node Disch. (acres) (min) (in/hr) cfs) (cfs) (cfs) --------------------------------------------------------------------------------- A-1 Curb 0.468 16.22 25.77 5.39 0.000 0.00 40.964 A-2 Curb 0.450 3.74 20.00 6.21 0.000 0.00 10.450 A-3 Curb 0.450 3.98 25.00 5.49 0.000 0.00 9.831 A-4 Curb 0.900 0.26 10.00 8.63 0.000 0.00 2.020 A-5 Curb 0.461 8.04 25.12 5.47 0.000 0.00 20.283 A-6 Curb 0.450 6.29 25.00 5.49 0.000 0.00 15.536 OUT JnctBx 0.468 16.22 25.77 5.39 0.000 0.00 40.964 Jl JnctBx 0.467 12.28 25.74 5.40 0.000 0.00 30.932 J2 Jn ct Bx 0.475 8.30 25.17 5.47 0.000 0.00 21.542 Conveyance Configuration Data ================================================================================= Run# Node I.D. Flowline Elev. US DS US DS Shape # (ft) (ft) Page 2 Span (ft) Rise (ft) Length (ft) Slope ( % ) n value " stmOutput 1 A-1 OUT 304.86 303.48 Box 1 4.00 3.00 405.40 0.34 0.013 2 A-2 A-1 305.90 304.86 Circ 1 o.oo 1. 50 22.70 4.59 0.013 3 Jl A-1 305.01 304.86 Circ 1 0.00 2.00 15.40 0.97 0.013 4 A-3 Jl 305.74 305.51 Circ 1 0.00 1. 50 22.50 1. 02 0.013 5 J2 Jl 306.13 305.01 Circ 1 0.00 2.00 237.60 0.47 0.013 6 A-4 J2 306.77 306.63 Circ 1 0.00 1. 50 14.20 0.99 0.013 7 A-5 J2 306.34 306.13 Circ 1 0.00 2.00 21. 60 0.97 0.013 8 A-6 A-5 306.90 306.34 Circ 1 0.00 2.00 56.00 1. 00 0.013 --------------------------------------------------------------------------------- Conveyance Hydraulic Computations. Tailwater = 0.000 (ft) ================================================================================= Hydraulic Gradeline Depth Run# US Elev DS Elev Fr.Slope Unif. Actual (ft) (ft) ( % ) (ft) (ft) 1 306.50 305.12 0.110 1. 64 1. 64 2* 307.14 306.50 0.989 0.72 1. 50 3 307.18 306.74 1. 869 2.00 2.00 4* 307.38 307.18 0.876 1.14 1. 50 5 309.34 307.18 0.907 2.00 2.00 6* 309.34 309.34 0.037 0.45 1. 50 7* 309.51 309.34 0.804 1. 50 2.00 8* 309.77 309.51 0.472 1. 22 2.00 Velocity Unif. Actual (f/s) (f/s) 6.24 6.24 12.50 5.91 9.85 9.85 6.84 5.56 6.86 6.86 4.56 1.14 8.03 6.46 7.75 4.95 Q (cfs) 40.96 10.45 30.93 9.83 21.54 2.02 20.28 15.54 Cap (cfs) 72.21 22.50 22.33 10.62 15.53 10.43 22.31 22.63 June Loss (ft) 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ================================================================================= OUTPUT FOR ANALYSYS FREQUENCY of: 100 Years ============================================= Runoff Computation for Analysis Frequency. ============================================================================= ID C Value Area Tc (acre) (min) Tc Used (min) Intensity (in/hr) Supply Q (cfs) Total Q (cfs) ----------------------------------------------------------------------------- A-1 0.9 0.20 10.00 10.00 11. 64 0.000 2.095 A-2 0.45 3.74 20.00 20.00 8.43 0.000 14.188 A-3 0.45 3.98 25.00 25.00 7.48 0.000 13.392 A-4 0.9 0.26 10.00 10.00 11.64 0.000 2.724 A-5 0.5 1. 75 25.00 25.00 7.48 0.000 6.543 A-6 0.45 6.29 25.00 25.00 7.48 0.000 21.165 Page 3 -. On Grade Inlet Configuration Data stmOutput =============================================================================== Inlet ID Inlet Type Inlet Slopes Length Long Trans (ft) ( % ) ( % ) Gutter n Depr. (ft) Grate Width Type (ft) Pond Width Allowed (ft) Critic Elev. (ft) ------------------------------------------------------------------------------- A-2 Curb 5.00 6.37 2.00 0.014 0.33 n/a n/a 12.00 309.10 A-4 Curb 5.00 0.36 2.00 0.014 0.33 n/a n/a 12.00 310.50 A-5 Curb 10.00 27.00 2.00 0.014 0.33 n/a n/a 12.00 310.50 On Grade Inlets Conmputation Data. ================================================================================= Inlet ID A-2 A-4 A-5 Inlet Type Curb Curb Curb Total Q (cfs) 14.188 2.724 6.543 Intercept Capacity (cfs) 3.410 2.405 3.270 Sag Inlets Configuration Data. Q Bypass Allow Actual (cfs) (cfs) 0.000 0.250 0.250 10.779 0.318 3.273 To Inlet Required ID Length A-1 A-1 A-3 (ft) 35.31 7.18 31. 31 Actual Length (ft) 5.00 5.00 10.00 Ponded Width (ft) 13.10 12.10 7.45 ================================================================================= Inlet ID A-1 A-3 A-6 Inlet Length/ Grate Type Perim. Area (ft) (sf) Curb 10.00 Curb 8.00 Curb 10.00 n/a n/a n/a Left-Slope Long Trans ( % ) ( % ) 0.60 2.00 38.30 2.00 2.70 2.00 Sag Inlets Computation Data. Right-Slope Long Trans ( % ) ( % ) Gutter n DeprW (ft) 0.30 0.50 0.16 2.00 0.014 2.00 0.014 2.00 0.014 1. 50 1. 50 1. 50 Depth Allowed (ft) 0.50 0.50 0.50 Critic Elev. (ft) 309.00 310.40 310.80 ================================================================================ Inlet ID Inlet Type Length (ft) Grate Perim Area (ft) (sf) Total Q Inlet Capacity (cfs) (cfs) Total Head (ft) Ponded Width Left Right (ft) (ft) -------------------------------------------------------------------------------- A-1 Curb 10.00 n/a n/a 13.192 13.436 0.491 19.45 7.35 A-3 Curb 8.00 n/a n/a 16.665 10.749 0.851 7.65 17.30 A-6 Curb 10.00 n/a n/a 21.165 13.436 0.870 13.80 23.40 Cumulative Junction Discharge Computations ================================================================================= Node Node Weighted Cumulat. Cumulat. Intens. User Additional Total Page 4 stmOutput I. D. Type C-Value Dr.Area Tc Supply Q Q in Node Disch. (acres) (min) (in/hr) cfs) (cfs) (cfs) --------------------------------------------------------------------------------- A-1 Curb 0.468 16.22 25.60 7.38 0.000 0.00 56.041 A-2 Curb 0.450 3.74 20.00 8.43 0.000 0.00 14.188 A-3 Curb 0.450 3.98 25.00 7.48 0.000 0.00 13.392 A-4 Curb 0.900 0.26 10.00 11.64 0.000 0.00 2.724 A-5 Curb 0.461 8.04 25.11 7.46 0.000 0.00 27.638 A-6 Curb 0.450 6.29 25.00 7.48 0.000 0.00 21.165 OUT JnctBx 0.468 16.22 25.60 7.38 0.000 0.00 56.041 Jl JnctBx 0.467 12.28 25.58 7.38 0.000 0.00 42.310 J2 JnctBx 0.475 8.30 25.15 7.45 0.000 0.00 29.357 --------------------------------------------------------------------------------- Conveyance Configuration Data ================================================================================= Run# Node I.D. Flowline Elev. US DS US DS Shape # Span Rise Length Slope n value (ft) (ft) (ft) (ft) (ft) ( % ) 1 A-1 OUT 304.86 303.48 Box 1 4.00 3.00 405.40 0.34 0.013 2 A-2 A-1 305.90 304.86 Circ 1 0.00 1. so 22.70 4.59 0.013 3 Jl A-1 305.01 304.86 Circ 1 0.00 2.00 15.40 0.97 0.013 4 A-3 Jl 305.74 305.51 Circ 1 0.00 1. 50 22.50 1. 02 0.013 5 J2 Jl 306.13 305.01 Circ 1 0.00 2.00 237.60 0.47 0.013 6 A-4 J2 306.77 306.63 Circ 1 0.00 1. 50 14.20 0.99 0.013 7 A-5 J2 306.34 306.13 Circ 1 0.00 2.00 21.60 0.97 0.013 8 A-6 A-5 306.90 306.34 Circ 1 0.00 2.00 56.00 1. 00 0.013 Conveyance Hydraulic Computations. Tailwater = 0.000 (ft) ================================================================================= Hydraulic Gradeline Depth Run# US Elev DS Elev Fr.Slope Unif. Actual (ft) (ft) (%) (ft) (ft) 1 306.92 305.54 0.205 2.06 2.06 2* 307.34 306. 92 1. 824 0.86 1. 50 3 307.46 306.92 3.497 2.00 2.00 4 307.83 307.46 1. 625 1. 50 1. 50 5 311.46 307.46 1.684 2.00 2.00 6* 311.47 311.46 0.067 0.52 1. 50 7 311.78 311.46 1. 492 2.00 2.00 8* 312.27 311.78 0.875 1. 53 2.00 Page 5 Velocity Unif. Actual (f/s) (f/s) 6.79 6.79 13.46 8.03 13.47 13.47 7.58 7.58 9.34 9.34 4.95 1. 54 8.80 8.80 8.20 6.74 Q (cfs) 56.04 14.19 42.31 13.39 29.36 2.72 27.64 21.17 Cap (cfs) 72.21 22.50 22.33 10.62 15.53 10.43 22.31 22.63 June Loss (ft) 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 stmOutput ===================================END=========================================== * Super critical flow. NORMAL TERMINATION OF WINSTORM. Warning Messages for current project: Runoff Frequency of: 10 Years Capacity of grade inlet exceeded at inlet Id= A-2 Capacity of grade inlet exceeded at inlet Id= A-4 Capacity of grade inlet exceeded at inlet Id= A-5 Computed left ponded width exceeds allowable width at inlet Id= A-1 Computed right ponded width exceeds allowable width at inlet Id= A-3 Capacity of sag inlet exceeded at inlet Id= A-3 Computed right ponded width exceeds allowable width at inlet Id= A-6 Computed left ponded width exceeds allowable width at inlet Id= A-6 Capacity of sag inlet exceeded at inlet Id= A-6 Tailwater set to uniform depth elevation= 305.12(ft) Run# 3 Insufficient capacity. Run# 5 Insufficient capacity. Runoff Frequency of: 100 Years Capacity of grade inlet exceeded at inlet Id= A-2 Computed ponded width exceeds allowable width at inlet Id= A-2 Capacity of grade inlet exceeded at inlet Id= A-4 Computed ponded width exceeds allowable width at inlet Id= A-4 Capacity of grade inlet exceeded at inlet Id= A-5 Computed left ponded width exceeds allowable width at inlet Id= A-1 Computed right ponded width exceeds allowable width at inlet Id= A-3 Capacity of sag inlet exceeded at inlet Id= A-3 Computed right ponded width exceeds allowable width at inlet Id= A-6 Computed left ponded width exceeds allowable width at inlet Id= A-6 Capacity of sag inlet exceeded at inlet Id= A-6 Tailwater set to uniform depth elevation= 305.54(ft) Run# 3 Insufficient capacity. Run# 4 Insufficient capacity. Run# 5 Insufficient capacity. Upstream hydraulic gradeline exceeds critical elevation at node Id= J2 Upstream hydraulic gradeline exceeds critical elevation at node Id= A-4 Run# 7 Insufficient capacity. Upstream hydraulic gradeline exceeds critical elevation at node Id= A-5 Upstream hydraulic gradeline exceeds critical elevation at node Id= A-6 Page 6 WinStorm (STORM DRAIN DESIGN) PROJECT NAME : Lincoln Center JOB NUMBER 138-0181 stmOutput Version 3.05, Jan. 25, 2002 Run @ 2/16/2004 7:40:40 AM PROJECT DESCRIPTION : Storm Sewer System -Proposed Conditions DESIGN FREQUENCY ANALYSYS FREQUENCY MEASUREMENT UNITS: 10 Years 100 Years ENGLISH OUTPUT FOR DESIGN FREQUENCY of: 10 Years =========================================== Runoff Computation for Design Frequency. ============================================================================= ID C Value A-1 0.9 A-2 0.45 A-3 0.45 A-4 0.9 A-5 0.5 A-6 0.45 Area (acre) 0.20 3.74 3.98 0.26 1. 75 6.29 Tc (min) 10.00 20.00 25.00 10.00 25.00 25.00 Tc Used (min) 10.00 20.00 25.00 10.00 25.00 25.00 Intensity (in/hr) 8.63 6.21 5.49 8.63 5.49 5.49 Supply Q (cfs) 0.000 0.000 0.000 0.000 0.000 0.000 Total Q (cfs) 1.554 10.450 9.831 2.020 4.803 15.536 On Grade Inlet Configuration Data =============================================================================== Inlet ID A-2 A-4 A-5 Inlet Type Curb Curb Curb Inlet Slopes Gutter Length Long Trans n Depr. (ft) (%) (%) 5.00 6.37 5.00 0.36 10.00 27.00 2.00 0.014 2.00 0.014 2.00 0.014 (ft) 0.33 0.33 0.33 On Grade Inlets Conmputation Data. Grate Width Type (ft) n/a n/a n/a n/a n/a n/a Pond Width Allowed (ft) 12.00 12.00 12.00 Critic Elev. (ft) 309.10 310.50 310.50 ================================================================================= Inlet ID A-2 A-4 A-5 Inlet Type Curb Curb Curb Total Q (cfs) 10.450 2.020 4.803 Intercept Capacity (cfs) 2.976 1. 939 2.744 Q Bypass Allow Actual (cfs) (cfs) 0.000 0.250 0.250 7.474 0.082 2.058 Page 1 To Inlet Required ID Length A-1 A-1 A-3 (ft) 29.43 6.01 26.63 Actual Length (ft) 5.00 5.00 10.00 Ponded Width (ft} 11.70 10.80 6.65 stmOutput Sag Inlets Configuration Data. ================================================================================= Inlet ID A-1 A-3 A-6 Inlet Length/ Grate Type Perim. Area (ft) (sf) Left-Slope Long Trans ( % ) ( % ) Grate 14.70 Curb 8.00 Curb 10.00 5.00 0.60 2.00 n/a 38.30 2.00 n/a 2.70 2.00 Sag Inlets Computation Data. Right-Slope Long Trans ( % ) ( % ) Gutter n DeprW (ft) 0.30 0.50 0.16 2.00 0.014 2.00 0.014 2.00 0.014 n/a 1. 50 1. 50 Depth Allowed (ft) 0.50 0.50 0.50 Critic Elev. (ft) 309.00 310.40 310.80 ================================================================================ Inlet ID Inlet Type Length Grate Perim Area (ft) (sf) Total Q Inlet Capacity A-1 A-3 A-6 Grate Curb Curb (ft ) n/a 8.00 10.00 Cumulative Junction 14.70 5.00 n/a n/a n/a n/a (cfs ) (cfs) 9.110 11.889 15.536 16.044 10.749 13.436 Discharge Computations Total Head (ft) 0.343 0.556 0.584 Ponded Width Left Right (ft) (ft) 16.95 6.75 12.25 6.40 15.25 20.85 ================================================================================= Node Node Weighted Cumulat. Cumulat. Intens. User Additional Total I. D. Type C-Value Dr.Area Tc Supply Q Q in Node Disch. (acres) (min) (in/hr) cfs) (cfs) (cfs) --------------------------------------------------------------------------------- A-1 Grate 0.468 16.22 25.77 5.39 0.000 0.00 40.964 A-2 Curb 0.450 3.74 20.00 6.21 0.000 0.00 10.450 A-3 Curb 0.450 3.98 25.00 5.49 0.000 0.00 9.831 A-4 Curb 0.900 0.26 10.00 8.63 0.000 0.00 2.020 A-5 Curb 0.461 8.04 25.12 5.47 0.000 0.00 20.283 A-6 Curb 0.450 6.29 25.00 5.49 0.000 0.00 15.536 OUT JnctBx 0.468 16.22 25.77 5.39 0.000 0.00 40.964 Jl JnctBx 0.467 12.28 25.74 5.40 0.000 0.00 30.932 J2 JnctBx 0.475 8.30 25.17 5.47 0.000 0.00 21.542 Conveyance Configuration Data ================================================================================= Run# Node I.D. Flowline Elev. US OS US OS (ft) (ft) Shape # Page 2 Span (ft) Rise (ft) Length (ft) Slope ( % ) n value stmOutput 1 A-1 OUT 304.86 303.48 Box 1 4.00 3.00 405.40 0.34 0.013 2 A-2 A-1 305.90 304.86 Circ 1 0.00 1. 50 22.70 4.59 0.013 3 Jl A-1 305.01 304.86 Circ 1 0.00 2.00 15.40 0.97 0.013 4 A-3 Jl 305.74 305.51 Circ 1 0.00 1. 50 22.50 1. 02 0.013 5 J2 Jl 306.13 305.01 Circ 1 0.00 2.00 237.60 0.47 0.013 6 A-4 J2 306.77 306.63 Circ 1 0.00 1. 50 14.20 0.99 0.013 7 A-5 J2 306.34 306.13 Circ 1 0.00 2.00 21.60 0.97 0.013 8 A-6 A-5 306.90 306.34 Circ 1 0.00 2.00 56.00 1. 00 0.013 --------------------------------------------------------------------------------- Conveyance Hydraulic Computations. Tailwater = 0.000 (ft) ================================================================================= Hydraulic Gradeline Depth Run# US Elev OS Elev Fr.Slope Unif. Actual (ft) (ft) (%) (ft) (ft) 1 306.50 305.12 0.110 1. 64 1. 64 2* 307.14 306.50 0.989 0.72 1. 50 3 307.18 306.74 1.869 2.00 2.00 4* 307.38 307.18 0.876 1.14 1. 50 5 309.34 307.18 0.907 2.00 2.00 6* 309.34 309.34 0.037 0.45 1. 50 7* 309.51 309.34 0.804 1. 50 2.00 8* 309.77 309.51 0.472 1. 22 2.00 Velocity Unif. Actual (f/s) (f/s) 6.24 6.24 12.50 5.91 9.85 9.85 6.84 5.56 6.86 6.86 4.56 1.14 8.03 6.46 7.75 4.95 Q (cfs) 40.96 10.45 30.93 9.83 21.54 2.02 20.28 15.54 Cap (cfs) 72.21 22.50 22.33 10.62 15.53 10.43 22.31 22.63 June Loss (ft) 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ================================================================================= OUTPUT FOR ANALYSYS FREQUENCY of: 100 Years ============================================= Runoff Computation for Analysis Frequency. ============================================================================= ID C Value Area Tc (acre) (min) A-1 0.9 0.20 10.00 A-2 0.45 3.74 20.00 A-3 0.45 3.98 25.00 A-4 0.9 0.26 10.00 A-5 0.5 1. 75 25.00 A-6 0.45 6. 29 25.00 Tc Used (min) 10.00 20.00 25.00 10.00 25.00 25.00 Page 3 Intensity (in/hr) 11.64 8.43 7.48 11.64 7.48 7.48 Supply Q (cfs) 0.000 0.000 0.000 0.000 0.000 0.000 Total Q (cfs) 2.095 14.188 13.392 2.724 6.543 21.165 stmOutput On Grade Inlet Configuration Data =============================================================================== Inlet ID Inlet Type Inlet Slopes Length Long Trans (ft) ( % ) ( % ) Gutter n Depr. (ft) Grate Width Type (ft) Pond Width Allowed (ft) Critic Elev. (ft) A-2 A-4 A-5 Curb Curb Curb 5.00 6.37 2.00 0.014 5.00 0.36 2.00 0.014 10.00 27.00 2.00 0.014 On Grade Inlets Conmputation Data. 0.33 0.33 0.33 n/a n/a n/a n/a n/a n/a 12.00 12.00 12.00 309.10 310.50 310.50 ================================================================================= Inlet ID Inlet Type Total Q Intercept Capacity (cfs) Q Bypass Allow Actual (cfs) (cfs) To Inlet Required Actual Length (ft) Ponded Width (ft) A-2 A-4 A-5 Curb Curb Curb (cfs) 14.188 2.724 6.543 3.410 2.405 3.270 Sag Inlets Configuration Data. 0.000 0.250 0.250 10.779 0.318 3.273 ID Length A-1 A-1 A-3 (ft) 35.31 7.18 31. 31 5.00 5.00 10.00 13.10 12.10 7.45 ================================================================================= Inlet Inlet Length/ Grate ID Type Perim. Area (ft) (sf) Left-Slope Long Trans ( % ) ( % ) A-1 A-3 A-6 Grate 14.70 Curb 8.00 Curb 10.00 5.00 0.60 2.00 n/a 38.30 2.00 n/a 2.70 2.00 Sag Inlets Computation Data. Right-Slope Long Trans ( % ) ( % ) Gutter n DeprW (ft) 0.30 0.50 0.16 2.00 0.014 2.00 0.014 2.00 0.014 n/a 1. 50 1. 50 Depth Allowed (ft) 0.50 0.50 0.50 Critic Elev. (ft) 309.00 310.40 310.80 ================================================================================ Inlet ID A-1 A-3 A-6 Inlet Type Grate Curb Curb Length (ft) n/a 8.00 10.00 Grate Perim Area (ft) (sf) 14.70 n/a n/a 5.00 n/a n/a Total Q Inlet Capacity (cfs) (cfs) 13.192 16.665 21.165 16.044 10.749 13.436 Cumulative Junction Discharge Computations Total Head (ft) 0.439 0.851 0.870 Ponded Width Left Right (ft) (ft) 19.45 7.65 13.80 7.35 17.30 23.40 ================================================================================= Node Node Weighted Cumulat. Cumulat. Intens. User Additional Total Page 4 stmOutput I. D. Type C-Value Dr.Area Tc Supply Q Q in Node Disch. (acres) (min) (in/hr) cfs) (cfs) (cfs) --------------------------------------------------------------------------------- A-1 Grate 0.468 16.22 25.60 7.38 0.000 0.00 56.041 A-2 Curb 0.450 3.74 20.00 8.43 0.000 0.00 14.188 A-3 Curb 0.450 3.98 25.00 7.48 0.000 0.00 13.392 A-4 Curb 0.900 0.26 10.00 11. 64 0.000 0.00 2.724 A-5 Curb 0.461 8.04 25.11 7.46 0.000 0.00 27.638 A-6 Curb 0.450 6.29 25.00 7.48 0.000 0.00 21.165 OUT JnctBx 0.468 16.22 25.60 7.38 0.000 0.00 56.041 Jl JnctBx 0.467 12.28 25.58 7.38 0.000 0.00 42.310 J2 JnctBx 0.475 8.30 25.15 7.45 0.000 0.00 29.357 --------------------------------------------------------------------------------- Conveyance Configuration Data ================================================================================= Run# Node I.D. US DS 1 A-1 OUT 2 A-2 A-1 3 Jl A-1 4 A-3 Jl 5 J2 Jl 6 A-4 J2 7 A-5 J2 8 A-6 A-5 Flowline Elev. US DS (ft) (ft) 304.86 303.48 305.90 304.86 305.01 304.86 305.74 305.51 306.13 305.01 306.77 306.63 306.34 306.13 306.90 306.34 Shape # Box 1 Circ 1 Circ 1 Circ 1 Circ 1 Circ 1 Circ 1 Circ 1 Span (ft) 4.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Rise (ft) 3.00 1. 50 2.00 1. 50 2.00 1. 50 2.00 2.00 Conveyance Hydraulic Computations. Tailwater = 0.000 (ft) Length (ft) 405.40 22.70 15.40 22.50 237.60 14.20 21. 60 56.00 Slope ( % ) 0.34 4.59 0.97 1. 02 0.47 0.99 0.97 1. 00 n value 0.013 0.013 0.013 0.013 0.013 0.013 0.013 0.013 ================================================================================= Hydraulic Gradeline Depth Run# US Elev DS Elev Fr.Slope Unif. Actual (ft) (ft) (%) (ft) (ft) 1 306.92 305.54 0.205 2.06 2.06 2* 307.34 306.92 1. 824 0.86 1. 50 3 307.46 306.92 3.497 2.00 2.00 4 307.83 307.46 1.625 1. 50 1. 50 5 311.46 307 .46 1. 684 2.00 2.00 6* 311.47 311.46 0.067 0.52 1. 50 7 311.78 311.46 1. 492 2.00 2.00 8* 312.27 311.78 0.875 1. 53 2.00 Page 5 Velocity Unif. Actual (f/s) (f/s) 6.79 6.79 13.46 8.03 13.47 13.47 7.58 7.58 9.34 9.34 4.95 1. 54 8.80 8.80 8.20 6.74 Q (cfs) 56.04 14.19 42.31 13.39 29.36 2.72 27.64 21.17 Cap (cfs) 72.21 22.50 22.33 10.62 15.53 10.43 22.31 22.63 June Loss (ft) 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 stmOutput ===================================END=========================================== * Super critical flow. NORMAL TERMINATION OF WINSTORM. Warning Messages for current project: Runoff Frequency of: 10 Years Capacity of grade inlet exceeded at inlet Id= A-2 Capacity of grade i nlet exceeded at inlet Id= A-4 Capacity of grade inlet exceeded at inlet Id= A-5 Computed left ponded width exceeds allowable width at inlet Id= A-1 Computed right ponded width exceeds allowable width at inlet Id= A-3 Capacity of sag inlet exceeded at inlet Id= A-3 Computed right ponded width exceeds allowable width at inlet Id= A-6 Computed left ponded width exceeds allowable width at inlet Id= A-6 Capacity of sag inlet exceeded at inlet Id= A-6 Tailwater set to uniform depth elevation= 305.12(ft) Run# 3 Insufficient capacity. Run# 5 Insufficient capacity. Runoff Frequency of: 100 Years Capacity of grade inlet exceeded at inlet Id= A-2 Computed ponded width exceeds allowable width at inlet Id= A-2 Capacity of grade inlet exceeded at inlet Id= A-4 Computed ponded width exceeds allowable width at inlet Id= A-4 Capacity of grade inlet exceeded at inlet Id= A-5 Computed left ponded width exceeds allowable width at inlet Id= A-1 Computed right ponded width exceeds allowable width at inlet Id= A-3 Capacity of sag inlet exceeded at inlet Id= A-3 Computed right ponded width exceeds allowable width at inlet Id= A-6 Computed left ponded width exceeds allowable width at inlet Id= A-6 Capacity of sag inlet exceeded at inlet Id= A-6 Tailwater set to uniform depth elevation= 305.54(ft) Run# 3 Insufficient capacity. Run# 4 Insufficient capacity. Run# 5 Insufficient capacity. Upstream hydraulic gradeline exceeds critical elevation at node Id= J2 Upstream hydraulic gradeline exceeds critical elevation at node Id= A-4 Run# 7 Insufficient capacity. Upstream hydraulic gradeline exceeds critical elevation at node Id= A-5 Upstream hydraulic gradeline exceeds critical elevation at node Id= A-6 Page 6 VbLf'\I FOR OFFICE Utt ONLY P&Z CASE NO.: 0 -3CJ DATE SUBMITTED~-/ {g -Ol- SITE PLAN APPLICATION MINIMUM SUBMITTAL REQUIREMENTS _i_ Site plan application completed in full. ~ $200.00 Application Fee . .!:If!... $200.00 Development Permit Application Fee . m.~ q: JO Jltri Jif.a $600.00 Public Infrastructure Inspection Fee if applicable . (This fee is payable if construction of a public v' waterline, sewerline , sidewalk, street or drainage facilities is involved.) __ Eleven ( 11) folded copies of site plan __ One (1) folded copy of the landscape plan . \/Qo"ll1ot.0 €>'-f PA\'2.~ DtP"t · .J::Jl1 One (1) copy of building elevation required for buildings with a footprint of 20,000 sq. ft . or greater t::1.h._ A list of building materials for all facades that are visible from the public right-of-way . _LA copy of the attached site plan checklist with all items checked off or a brief explanation as to why they are not checked off. ~Parkland Dedication requirement approved by the Parks & Recreation Board , please provide proof of approval (if applicable). Date of Preapplication Conference: __ Ja=n-..u=a .... rv ........ 5-.. • .-2-..00-..4...__ _______________ _ NAME OF PROJECT Lincoln Community Center -Expansion & Multipurpose Pavilion ADDRESS 1000 Eleanor Street, College Station, TX 77840 LEGAL DESCRIPTION ____________________________ _ APPLICANT/PROJECT MANAGER 'S INFORMATION (Primary Contact for the Project): Name Rabon Metcalf Engineering <RME> Street Address __ P __ .o __ ..... e .... o .... x ..... 92 ..... 5 ... 3 ____________ _ City College Station E-Mail Address rrnenglneer@iuno.com Fax Number (979) 690-0329 State ..... TX ______ Zip Code .._77.....,.84-......-.2 ___ _ Phone Number (979) 219-4174 PROPERTY OWNER'S INFORMATION : Name City of College Station -Parks & Recreation Department Street Address 1000 Krenek Tap Road City College Station State TX Zip Code ..... 77 ...... 840 ........... ___ _ E-Mail Address ------------- Phone Number ... <9 ..... 7 ..... 9)._.7......,64-348 ......................... 6.___ _____ _ Fax Number (979) 764-3737 ARCHITECT OR ENGINEER'S INFORMATION : Name Same As Appllcant Street Address -----------------City--------- State -----Zip Code------E-Mail Address ------------- Phone Number -----------Fax Number _____________ _ 6113/03 I of6 OTHER CONTACTS (Please specify type of contact, i.e. project manager, potential buyer, local c::ontact , etc.) Name Holster & Associates -Architect Street Address 7607 Eastmarls Drive. Suite 200 City College Station State TX Zip Code ...... 77 ...... 84 ............. 0 ___ _ E-Mail Address ------------ Fax Number (979) 693-8370 Phone Number """'<9-...7.:.-9)'""'6"""9..-3-"-3""'"17~9~------ CURRENT ZONING _________________________ _ PRESENT USE OF PROPERTY ..-C..-o=m=m;..;.;u=n=itv""'-'C""'e=n=te=r.__ _________________ _ PROPOSEDUSEOFPROPERTY ..-C..-o=m=m;..;.;u=n=~~C""'e=n=~=r.__ ________________ _ VARIANCE($) REQUESTED AND REASON(S) .-..No=n-..-e _________________ _ #OF PARKING SPACES REQUIRED ......,10 ...... 1 __ #OF PARKING SPACES PROVIDED ......,10 ...... 1 __ MUL Tl-FAMILY RESIDENTIAL PARKLAND DEDICATION Total Acreage ____ _ # of Multi-Family Dwelling Units Floodplain Acreage __ _ _ __ x $452 = $ _______ _ Housing Units ____ _ _ __ # of acres in floodplain # of 1 Bedroom Units # of acres in detention ------ # of 2 Bedroom Units ---___ # of acres in greenways # of 3 Bedroom Units ---___ date dedication approved by Parks Board ___ # of 4 Bedroom Units COMMERCIAL FOR 2 BEDROOM UNITS ONLY Total Acreage-------- ___ # Bedrooms = 132 sq . ft. Building Square Feet ____ _ ___ #Bedrooms< 132 sq. ft. Floodplain Acreage _____ _ NOTE: Parkland Dedication fee Is due prior to the Issuance of a Bulldlng Pennit. The applicant has epared this application and certifies that the facts stated herein and exhibits attached hereto are true and correct. February 16, 2004 Date SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION Application is hereby made for the following development specific site/waterway alterations: Increased impervious cover from expansion of Lincoln Communitv Center complex located in the watershed of Tributary B of Bee Creek. ACKNOWLEDGMENTS: I, Rabon A. Metcalf. P.E. , design engineer/owner, hereby acknowledge or affirm that: The information and conclusions contained in the above plans and supporting documents comply with the current requirements of the ity of College Station , Texas City Code, Chapter 13 and its associated Drainage Policy and Design Standards. As a co ition of approval of this permit application, I agree to construct the improvements proposed in this appli rdin to these documents and the requirements of Chapter 13 of the College Station City Code. Contractor CERTIFICATIONS: (for proposed alterations within designated flood hazard areas.) A.I , Rabon A. Metcalf .E. certify that any nonresidential structure on or proposed to be on this site as part of this applicati n is designated to prevent damage to the structure or its contents as a result of flooding from the 100 er1u~-rn.... Februay 16. 2004 Date B. I, Rabon A. Metcalf PE. certify that the finished floor elevation of the lowest floor, including any basement, of any residen al structure , proposed as part of this application is at or above the base flood elevation est · m the atest deral Insurance Administration Flood Hazard Study and maps, as amended . February 16, 2004 Date C. I, N/A , certify that the alterations or development covered by this permit shall not diminish the flood-carrying capacity of the waterway adjoining or crossing this permitted site and that such alterations or development are consistent with requirements of the City of College Station City Code, Chapter 13 concerning encroachments of floodways and of floodway fringes . Engineer Date D. I, NIA , do certify that the proposed alterations do not raise the level of the 100 year flood above elevation established in the latest Federal Insurance Administration Flood Hazard Study. Engineer Date Conditions or comments as part of approval : ------------------------- In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities . All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. ~ 1 . ~ 2. ~ 3. ~ ~ ~ ~ 4 . ~ 5. ~ 6 . ~ 7. ~ ~ ~ ~ I ut" ~ </) ~ ~ ~ \l ~ \() ef 8. ~ N/A a ~ ~ SUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 10 FOLDED COPIES OF SITE PLAN FOR REVIEW SITE PLAN MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: Sheet size -24" x 36" (minimum). A key map (not necessarily to scale). Title block to include: Name, address, location, and legal description Name, address, and telephone number of applicant Name, address, and telephone number of developer/owner (if differs from applicant) Name, address, and telephone number of architect/engineer (if differs from applicant) Date of submittal Total site area North arrow. Scale should be largest standard engineering scale possible on sheet. Ownership and current zoning of parcel and all abutting parcels. Existing locations of the following on or adjacent to the subject site : Streets and sidewalks (R.O.W .). Driveways (opposite and adjacent per Section 7 .3 of the Unified Development Ordinance). Buildings. Water courses. Show all easements clearly designating as existing and type (utility, access, etc.). 100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site, note if there is none on the site. Utilities (noting size and designate as existing) within or adjacent to the proposed site, including building transformer locations, above ground and underground service connections to buildings, and drainage inlets. Meter locations. Topography (2' max or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) Proposed location, type and dimensions of the following.: Phasing. Each phase must be able to stand alone to meet ordinance requirements . The gross square footage of all buildings and structures and the proposed use of each . If different uses are to be located in a single building, show the location and size of the uses within the building. Building separation is a minimum of 15 feet w/o additional fire protection. Setbacks. Show building setbacks as outlined in the Unified Development Ordinance, Article 5 . Off-Street parking areas with parking spaces drawn, tabulated, and dimensioned. Minimum parking space is 9' x 20', or on a perimeter row 9' x 18' with a 2' overhang . Designate number of parking spaces required by ordinance and provided by proposal. Handicap parking spaces. r-J/A CJ 1-1/A CJ "1/fr CJ ~/A CJ ~ ~ ~ ::: ~ NOTE: a;r"' 9 . ~ 10. Parking Islands. Raised landscape islands, (6" raised curb) a minimum of 180 sq. ft. are required at both ends of every parking row (greenspace area contiguous to the end island maybe applied toward the required 180 sq. ft.). Additionally, 180 sq. ft. of landscaping for every 15 interior parking spaces must be provided . All required islands must be landscaped or set with decorative pavers, or stamped dyed concrete or other decorative materials as approved . Drives. Minimum drive aisle width. Curb cuts . For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing curb cuts on the same opposite side of the street to determine separation distances between existing and proposed curb cuts. Indicate driveway throat length as measured in the Unified Development Ordinance, Section 7 .3 Access Management and Circulation. Security gates (show swing path and design specs with colors). Sidewalks (both public and private). Sidewalks are required at time of development if property has frontage on a street shown on the Sidewalk Master Plan or if the review staff determines the necessity. Medians. Show any and all traffic medians to be constructed on site. A fifteen foot parking setback from R.O.W. to curb of parking lot is required. Pavement may encroach into this 15' setback by up to 7 contiguous parking spaces. A double parking island (360 square feet) must be provided between each group of seven spaces. In no case may the pavement be less than 6' from the property line. Common open spaces sites Loading docks Detention ponds Guardrails Retaining walls Sites for solid waste containers with screening. Locations of dumpsters are accessible but not visible from streets or residential areas. Gates are discouraged and visual screening is required . (Minimum 12 x 12 pad required.) Show all easements clearly designating as proposed and type (utility, access, etc.). If dedicated by separate instrument list by volume and page. Utilities (noting size and designate as proposed) within or adjacent to the proposed site, including building transformer locations, above ground and underground service connections to buildings . Meter locations (must be located in public R.O.W. or public utility easement.). Proposed grading (1 ' max for proposed or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) Show proposed and existing fire hydrants. Fire hydrants must be located on the same side of a major street as a project, and shall be in a location approved by the City Engineer. Any structure in any zoning district other than R-1 , R-1A, or R-2 must be within 300 feet of a fire hydrant as measured along a public street, highway or designated fire lane. Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall they be any further than 300' apart, and they shall be accessible from the parking lot · without being blocked by parked cars or a structure . Show fire lanes. Fire lanes a minimum of 20 feet in width with a minimum height clearance of 14 feet must be established if any portion of the proposed structure is more than 150 feet from the curb line or pavement edge of a public street or highway. Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface as defined in the Zoning Ordinance Section 9 before a building permit can be issued . Will building be sprinkled? Yes ~ No CJ If the decision to sprinkle is made after the site plan has been approved, then the plan must be resubmitted. Wheelstops may be required when cars overhang onto property not owned by the applicant or where there may be conflict with handicap accessible routes or above ground utilities , signs or other conflicts. 11 . 0 12. 0 ~ cY /Ao site . /A~ 13 . 14. 15. 16 . 17. 18. 19. g 20 . NOTE: Show curb and pavement detail. A 6" raised curb is required around all edges of all parts of all paved areas without exception. (To include island, planting areas, access ways, dumpster locations, utility pads, etc.) No exception will be made for areas designated as "reserved for future parking". Landscape plans as required in Section 7.5 of the Unified Development Ordinance. The landscaping plan can be shown on a separate sheet if too much information is on the original site plan . If requesting protected tree points, then those trees need to be shown appropriately barricaded on the landscape plan. Attempt to reduce or eliminate plantings in easements. Include information on the plans such as: required point calculations additional streetscape points required. Streetscape compliance is required on all streets. calculations for # of street trees required and proposed (proposed street tree points will accrue toward total landscaping points.) proposed new plantings with points earned proposed locations of new plantings screening of parking lots, 50 % of all shrubs used for screening shall be evergreen. screening of dumpsters, concrete retaining walls , off street loading areas, utility connection points , or other areas potentially visually offensive. existing landscaping to remain show existing trees to be barricaded and barricade plan. Protected points will only be awarded if barricades are up before the first development permit is issued . Buffer as required in Section 7.6 of the Unified Development Ordinance. Show irrigation system plan. (or provide note on how irrigation system requirement will be met prior to issuance of C .O.) All plans must include irrigation systems for landscaping. Irrigation meters are separate from the regular water systems for buildings and will be sized by city according to irrigation demand submitted by applicant and must include backflow prevention protection. Is there any landscaping in TxDOT R.O.W.? Yes CJ No cg/ If yes, then TxDOT permit must be submitted. Will there be any utilities in TxDOT R.O.W .? Yes CJ No ~ If yes, then TxDOT permit must be submitted. Will there be access from a TxDOT R.O.W.? Yes CJ No ~ If yes, then TxDOT permit must be submitted. The total number of multi-family buildings and units to be constructed on the proposed project The density of dwelling units per acre of the proposed project. Provide a water and sanitary sewer legend to include water demands (minimum, maximum and average demands in gallons per minute) and sewer loadings (maximum demands in gallons per day). Are there impact fees associated with this development? Yes 0 Signs are to be permitted separately. No~ DEVELOPMENT SERVICES TRANSMITTAL LETTER Name/Firm : Rabon Metcalf I RME Date : 2116/0 4 Address: P.O . Box 9253. College Station. TX 77842 Phone: (979) 219-4174 Fax: ---~<9~7 ...... 9 .... ) 6 ...... 9 ...... 0 ...... -0 ...... 3~29..._ ____ _ We are transmitting the following for Development Services to review and comment: (Check all that apply.): D Master Development Plan w/ D Redlines D Preliminary Plat w/ D Redlines D Final Plat w/ D Redlines 0 FEMA CLOMA/CLOMR/LOMA/LOMR w/ D Redlines ~Site Plan w/ D Redlines ~ Grading Plan w/ D Redlines D Landscape Plan w/ D Redlines D Irrigation Plan w/ D Redlines D Building Construction Documentsw/ D Redlines INFRASTRUCTURE AND ENGINEERING DOCUMENTS All Infrastructure documents must be submitted as a complete set The following a ra included in the complete set: D Waterline Construction Documents w/ D Redlines D Sewerline Construction Documents w/ D Redlines D Drainage Construction Documents w/ D Redlines D Street Construction Documents w/ D Redlines D Easement application with metes & bounds decsription ~ Drainage Letter or Report w/ D Redlines D Fire Flow Analysis w/ D Redlines Special Instructions: D Development Permit App . D Conditional Use Permit D Rezoning Application D Variance Request D Other -Please specify -- -- D TxDOT Driveway Permit D TxDOT Utility Permit ~ Other -Please specify Various Detail Sheets Lincoln Community Center -Expansion & Multipurpose Pavilion -2 Complete set of construction drawings DEVELOPMENT PERMIT PERMIT NO . 04-11 ~-'1 COLllC.l !oTATION Project: LINCOLN COMMUNITY CENTER EXPANSION FOR AREAS OUTSIDE THE SPECIAL FLOOD HAZARD AREA RE: CHAPTER 13 OF THE COLLEGE STATION CITY CODE SITE LEGAL DESCRIPTION: Crawford Burnett League Tract 189 7 .75 Acres DATE OF ISSUE: 05/11/04 OWNER: City of College Station-Parks & Recreation Department 1000 Krenek Tap Road College Sation , Texas 77840 SITE ADDRESS: 1000 Eleanor Street DRAINAGE BASIN: Bee Creek Trib . "B" VALID FOR 12 MONTHS CONTRACTOR: TYPE OF DEVELOPMENT: Full Development Permit SPECIAL CONDITIONS: All construction must be in compliance with the approved construction plans All trees required to be protected as part of the landscape plan must be completely barricaded in accordance with Section 7.5.E., Landscape/Streetscape Plan Requirements of the City's Unified Development Ordinance , pr ior to any operations of this permit. The cleaning of equipment or materials within the drip line of any tree or group of trees that are protected and required to remain is strictly prohibited . The disposal of any waste material such as , but not limited to , paint , oil , solvents, asphalt, concrete , mortar, or other harmful liquids or materials within the drip line of any tree required to remain is also prohibited. TCEQ PHASE II RULES IN EFFECT. The Contractor shall take all necessary precautions to prevent silt and debris from leaving the immediate construction site in accordance with the approved erosion control plan as well as the City of College Station Drainage Policy and Design Criteria . If it is determined the prescribed erosion control measures are ineffective to retain all sediment onsite , it is the contractors responsibility to implement measures that will meet City , State and Federal requirements. The Owner and/or Contractor shall assure that all disturbed areas are sodden and establishment of vegetation occurs prior to removal of any silt fencing or hay bales used for temporary erosion control. The Owner and/or Contractor shall also insure that any disturbed vegetation be returned to its original condition , placement and state . The Owner and/or Contractor shall be responsible for any damage to adjacent properties , city streets or infrastructure due to heavy machinery and/or equipment as well as erosion , siltation or sedimentation resulting from the permitted work . In accordance with Chapter 13 of the Code of Ordinances of the City of College Station , measures shall be taken to insure that debris from construction , erosion , and sedimentation shall not be deposited in city streets , or existing drainage faci lities . I hereby grant this permit for development of an area outside the special flood hazard area . All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer in the development permit application for the above named project and all of the codes and ordinances of the City of College Station that apply . OS--f/-o 4 Owner/Agent/Contractor Date