HomeMy WebLinkAbout25 T-Mobile 04-07 1361 Earl Rudder FWY S~-v DEVELOPMENT PERMIT PERMIT NO . 04-07 Project: T-MOBILE CELL TOWER COlllGl STATION FOR AREAS INSIDE THE SPECIAL FLOOD HAZARD AREA RE : CHAPTER 13 OF THE COLLEGE STATION CITY CODE SITE LEGAL DESCRIPTION: High Ridge Lot 4R DATE OF ISSUE: 02/12/04 OWNER: Voice Stream Houston c/o John St . John 2 Greenway Plaza #1100 Houston , Texas 77046 SITE ADDRESS: 1361 Earl Rudder Freeway South DRAINAGE BASIN: Carter's Creek VALID FOR 9 MONTHS CONTRACTOR: TYPE OF DEVELOPMENT: Full Development Permit SPECIAL CONDITIONS: All construction must be in compliance w ith the approved construction plans All trees requ ired to be protected as part of the landscape plan must be completely barricaded in accordance with Section 7.5.E ., Landscape /Streetscape Plan Requ irements of the City's Unified Development Ordinance , prior to any operat ions of this permit. The cleaning of equipment or m aterials within the drip line of any tree or group of trees that are protected and req uired to rema in is strictly proh ibited . The disposal of any waste material such as , but not limited to , pa int , oil , so lvents , asphalt, concre te, mortar, or other harmful liquids or materials within the drip line of any tree requ ired to remain is also proh ibited . TCEQ PHASE II RULES EFFECT The Contracto r shall take all necessary precautions to prevent silt and debris from leaving the immediate construction site in accordance with the approved erosion control plan as well as the City of College Station Drainage Policy and Design C rite ria . If it is determined t he presc ri bed erosion control measures are ineffective to reta in all sediment ons ite , it is the contractors responsibility to implement measures that will meet City , State and Federal requirements . The Owner and/or Contractor shall assure that all disturb ed areas are sodden and establ ishment of vegetation occurs prior to removal of any silt fencing or hay bales used for te mp orary erosion control. The Owner and/or Contractor shall also insure that any disturbed vegetat ion be returned to its original condition , placement and state . The Owner and/or Contractor shall be responsible for any damage to adjace nt propert ies , city streets or infrastructure due to heavy machinery and/or equipment as well as erosion , siltation or sedimentation resulting from the permitted work . In accordance w ith Chapte r 13 of the Code of Ordinances of the City of College Station , measures shall be taken to insure that debris from construction , erosion , and sedimentation shall not be deposited in city streets , or existing drainage faci li t ies . I hereby grant thi s permi t for develop m e nt of an area ins ide the special flood hazard area . All development shall be in accordance wi th the plans and spec if ic ation s subm itted to and approved by the C ity Engineer in the development permit app li cation for the above named projec t a nd all of the codes and ordinances of the City of College Stat ion that apply . oz-\3-0~ Adm inistrator/Representative b~Si~ Owner/Agent/Contractor Date t D N E"""11'/\~RK ' INFRASTRUCTURE SOLUTIONS PAUL J. FORD AND COMPANY STRUCTURAL ENGINEERS 250 Eas t Broa d Street , Suite 500 , Columbu s, Ohio 43215 (6 14) 221-6679 Fa x: (614) 448-4105 www.PJFweb.com ~ 8 0 " ~ g g "' ..., / ..., 8 "' 120·-o· 105 ·-o· 90 ·-o· 83'-7" 75'-0" 60'-0" 6 34 '-9" "' ..., / u z -, ~ 0 ~ a: ~ z -, ~ ~ z I 0 "' ..., / ~ ~ 0 z 0 " / "' " z ~ 0 ( w ~ / .:; 102 SE TRY DRIVE MANSFIELD , TX 76063 (800) 726-2 72 6 Fax: (817) 473-1454 www.n ewma rk.com 16.250" ACROSS FLATS I(. 3/16" X 39 .75' (Fy=65) (EST WT = 1.681 KIPS) 4-SP LICE LENGTH MIN = 36 .00" DESIGN = 40.00" MAX = 44.00' I(. 3/16" X 53.75' (Fy=65) (EST WT = 3.379 KIPS) -t SP LICE LE NGTH MIN = 53 .10" DESIGN = 59 .00" MAX = 64.90" I(. 1/4" X 34 .75' (Fy =65) (EST WT = 3. 768 KIPS) BASE I(. 2" X 57.500" ROUND JOB DATA 1-P_o::.......:ec__1 _o.o..f--=2c__ ______ -.; Job No. By RW H Design No. 1--~----'-'-'.:..:..c._. ______ -.; Do le Chk d By / Rev. No. 32003-0148 NEWMARK 603-372 11 -~6-2003 Rev. Dole Pole 120-FT MONOPO LE Sile A3K021, VARS ITY FORD; CO LLE GE STATION, TEXAS Owner T-MOBILE Ref. No . 32003-0037 Desi gn 110 MPH DESIGN WIND VELOCITY 3-SECOND GUST ACCORDING TO THE INTERNATIONAL BUI LDING CODE 2000 L 0 A D C A S E S CASE 1 1 1 0 MPH WIT H NO ICE CASE 2 50 MPH WITH NO ICE 3-SECOND GUST DESIGN WIND OPERATIONAL WIND POLE SPECIFICATIONS Pole Sha e T e: 1 8-SIDED POLYGON Toper: 0 .242 708 IN FT Shofl St ee l: ASTM A572 GRAD E 65 Bo se PL Steel: ASTM A572 GRADE 50 50 KS I An cho r Bolts: 2 1 4 0 x 8 -0 LONG 18J ASTM A615 GRADE 75 ANTENNA L I ST No. I Elev. Descri ptio n TOP 3 4 LIGHTNING ROD 1-6 TOP (6) EMS OR65-18-00DPL20 PANEL TOP 12' LOW PROFIL E PLATFORM 7-12 105 .00 (6) EMS RR65-18-00DP PCS PANEL 105 .00 12' LOW PROFILE PLATFORM 13-18 90.00 (6) EMS RR65-18-00DP PCS PANEL 90 .00 12' LOW PROFI LE PLATFORM 19-24 75 .00 (6) EMS RR65-18-00DP PCS PANEL 75.00 12' LOW PROFILE PLATFORM 25 60.00 (1) 6' DIAM . GRID DISH (2 GHz) 26 60.00 1 6' DIAM . GRID DISH 180 DEG. Al.. 110 MPH WIND Latera l Rotation La tero ' Ele vation Deflection {sway) Deflection (Inches) (degrees) {Inches) TOP 60.5 4.219 12 .5 60.0 ' 15.1 2.467 3.2 NOTE : MONOPOL E WAS DESIGNED TO MEET MAXIMUM TW IST AND SWAY REQUIREM ENT S OF 4.6CT FOR A 6.0'0 DISH {2 .0 GHz) AT ELEV . 60 .0' WITH A 50 MP H WIND . SHAFT SECTION DATA Shaft Section Plate Lop Diameter Across Fl ats Section Length Thickness Splice (inches) (feet) (in .) {in.) @ To @ Bottom 1 39.75 0 . 1875 40.00 16.250 25 .898 2 53 .75 0 . 1875 59.00 24 .714 37 .759 3 34 .75 0.2500 36.19 1 44 .625 NOTE: DIMENSIONS SHOWN DO NOT INCLUDE GALVANIZING TOLERANCES BASE REACTIONS FOR FON DES IGN W/(8) 2.25'0 ANCHOR BO LTS EQUALLY SPACED ON 51.500" 8.C . WITH MIN . 7'-0" MOMENT = 1300 ft-kips SHEAR = 18 kip s EMBEDMENT INTO PIER (W/NUTS & TEMPLATE PLATE @ BOT.) TIGHTEN ANCHOR NUTS TO A!SC SNUG "TI GHT CONDITION . 44.625" ACROSS FLATS A AXIAL = 16 kips ~-o'l 2.-1,-D'f 1: 1 op1n a N E\/VJ\./\~RK INFRASTRUCTURE SOLUTIONS 10 2 SENTRY DRIVE MANSFIELD , TX 76063 (800) 726-2 726 Fax: (81 7) 473-1454 www.newmark.com POLE SHAFT & BASE PL. HEAVY HEX NUT 3" GAP (NO GROUT) I f- Cl z w _J z 0 (/) (/) <( u ::::;: ;::, ::::;: z ~ r..o I r..o TEMPLATE AND NUTS 3" CLR 12'-o'Vw.T. 0::: _J u ct_ POLE & FOUNDATION ANCHOR zZ oQ i== t; Uw w --, --, 0 0 0::: 6'-0"0 SHAFT BOLTS g: Cl.. :?; ~ ::::;: ::::;: 0 N 2" CLR FIN GRADE (12)-#5 TIES @ 6" C/C REM #5 TIES @ 18" C/C 2'-0" MIN LAP (14)-#11 VER T REINF FULL HEIGHT CAISSON (DRILLED PAUL J. FORD AND COMPANY STRUCTURAL ENGINEERS 250 East Broad Street, Suite 500 , Columbus, Ohio 43215 (614 ) 221-6679 Fax: (614 ) 448-4105 w~w.PJFweb.com J 0 B D AT A Page 2 o f 2 Job No . 32003-0148 By RW H Design No. NEWMARK NO. 03-372 Chk d By ~11 Dote 11-26-2003 Rev . No . Rev. Do te Pole 120-FT MONOPO LE Site A3K02 1 . VARSITY FORD: COLLEGE STATION. TEXAS Owne r T-MOBILE Ref. No. Design 110 MP H DESIGN WIN O VELO CITY (3-SECOND GUST) ACCORDING TO THE IBC 2000 NOTES: 1. AL L CONCRETE SHA LL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS. CONCRETE SHALL BE AIR ENTRAINED (6±1.5%). CONCRETE SHAL L HAVE A MAXIM UM WATER/CEMENT RATIO OF 0.46. ALL CONCRETE WORK SHALL BE IN ACCORDAN CE WITH "THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE", AC I 318, LATEST EDITION. FOUNDATION INSTA LLATI ON SHALL BE IN ACCORD ANC E WITH ACI 336, "STANDARD SPECIFICATIONS FOR THE CONS TRUCTION OF DRILLED PIERS", LATES T EDITION . 2. RE INFO RCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF AS TM A-615 (GRADE 60) EXCEPT THAT CAISSON TIES MAY BE AS TM A-615 (GRADE 40). ALL RE INFORCING DETAILS SHALL CONFORM TO "MANUA L OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRU CTURES", ACI 315 , LATEST ED ITI ON, UNLESS DETAILED OTHERWISE ON THIS DRAWING. .3 . SEE PAGE 1 FOR ANCHOR BO LT QUANTITY , SIZE, LEN GT H, AND BO LT CIRCLE . 4. TOTAL CONCRETE = 17.5 CUBIC YARDS . 5. FOUNDATION DESIGN IS BASED UPON GEOTECHNICAL EXPLO RATION REPOR T PREPARED BY: REPORT NO.: DATED: TERRA-MAR HE 02-128 09-10-2002 6. CONTRACTOR SHA LL READ THE GEOTECHNICAL REPORT AND CONSU LT THE GEOTECHNICAL ENGINEER AS NECESSARY PRIOR TO CONSTRUCTION. 7. GEOTECHNICAL REPORT INDICAT ES GROUNDWATER WAS ENCOU NTER ED AT 12'-0" BELOW GRADE. 8. THE FOUNDATION WAS DESIGNED USING THE FOLLOW ING SERVICE LOADS : MOMENT: SHEAR: AXIAL: 1300 FT -KIPS 18 KIPS 16 KIPS ........ ,,,,,, --11!. OF T~ir~ \ .-,,:5."·······~ft , .. -~ r: •• •.\iJ-•• '':>'···· * ··.. ., , .· ·.• ' ,, .· . * '*: ... ~ ... IA ,. . ······· .. r._.. ······· 'IL ..,_ f ··=········ RE.E.0 HAL-······i'- l K.\f\K ··•••·•••••••· :,..,,.~ 'I.············· :ii;; '• ~... 899~6 Q .·~ ,[\ e,'S>O~·~ICEN£>~.·~(]-"" lY '' ~ss····· ···'\,. ~~ 'L \\' ION/l. ...,.-W 0 I , ... ,.._-- \\.~ PIER) FOUNDATION Pa g e 1 of 8 PJF 32 00 3-0148 J ob Project Date Paul J. Fo rd & Company 250 £. Broad St ., Ste . 500 Columbus, OH 4321 5 Phone : (614) 221 -6679 FAX (614) 448-41 05 120' Monopole -A3 K02 1 , Vars ity Ford ; Coll eg Client e St atio n , T X 11 :04 :02 11 /26/03 Des i gned by Newmark I T -Mobile Towe r Input Data There is a pole section . This tower is designed using th e TWEIA-222-F standard. The fo ll owin g des ign criteria app ly: A 110 mp b 3-second peak gust ASCE 7-02 wind profile u sed (exp osure C). Wind imp ortance factor is 1.00 . Deflection s calculated u s ing a wind speed of 50 mpb. A n on -lin ear (P-de lta) analysis was u se d . Pressur es are calculated at each section . Stress ratio used in po le des ign is 1.333. Local bendin g stresses due to climb ing loads and fee dl ine supports are not co Options ns idered. Consider Moments -Legs C onsider Moments -Hmi zon tal s Con s ider Moments -Diagonal s Use Moment Magnification Di s tribute Leg Load s As Unifonn Assume Legs Pinned ndles A s Cylind er Treat Feedlin e Bu Use AS CE 10 X -B Calc ulate Redund Cons ider Feedline ../ Use Code Stress Rat ios ../ Use Code Safety Factors -Guys Es calate Ice Always Use Ma x Kz ../ Use Sp ecial Wind Profile ../ Incl ude Bolts In Member Capacity ../ Leg Bolts Are At Top Of Section ../ Secondary Horizontal Braces Leg ../ Assume Rigid Inde x Pla te Use C lear Spans For Wind Area Use C lea r S pan s For KUr Retension Guys To Init ial Tension Byp ass Mast S tabili ty Checks Use Azimuth D is h Coefficients Project Wind Area of Appurt. Autocalc Torque Ann Area s SR Members Have C ut End s race Ly Ru Je s ant Braci ng Forces Torque isl Compression ../ SR Leg Bolts Res ../ A 11 Le g Panels Ha Offset Girt At Fou p ve Sa me Allowable ndation oles ·sion Interac tion Include Shear-Tm Always Use Sub-C ../ Use Top Mounted ritical Fl ow Sockets Tapered Pole Section Geometr y Section Elevation Section Splice Number Top Bollom Wall Bend Pole Grade Ll 12 0.00 -80.25 L2 80.25 -2 9.83 L3 29 .83 -0.00 Section Tip Dia . in Ll 16.5007 2 6.2975 L2 25 .9167 Length Leng th of Diameter Diamecer Thickn ess I I S ides in in in 39.75 3.33 18 16.2500 2 5.8980 0.1 875 53.75 4 .92 18 24 .713 9 37.7590 0.1875 34.75 18 36 .1907 44 .6 250 0.2500 Tapered Pole Properties Area 1 r c ' . 4 in in m Ill 9.5592 311.5911 5.7022 8 .2 550 15.3010 12 77.8 422 9.12 72 13 .1562 14 .5963 1109.3009 8.7069 12 .5547 !IC J in 3 . 4 m 37.7457 623 .5922 97 . 12 86 255 7 .3657 88.3575 2220 .06 14 Jt!Q in ] 4 .78 7.65 7.29 05 19 95 Radius in 0.7500 A572 -65 (65 ksi) 0.7500 A572-65 (65 ksi) 1.0000 A572 -65 (65 ks i) w wi t in 2.5300 I 3.4 93 4.2 280 22.55 4 .0197 21.438 rt ea I ~ I I I I PJF Job Page 32003-0148 2 of 8 P aul J. Fo rd & Co mpany Project Date 250 £. B rand St .. S te. 500 120' Monopole -A3K02 1, Varsity Fo rd; College Station , T X 11 :04 :02 11 /26/03 Colu m bus, OH 432 I 5 Cli e nt Designed by Phone: (614) 221-6679 Newmark I T -M obi le rte al FAX: (614) 448 -4105 Section Tip D in. Aren r c /IC J /t/Q w w/1 in . , . ' in in in 3 . ' . , in ,,,-In Jn 111 - 38 .3415 22.3597 3987.6887 13.3379 19 .1816 207.8917 7980.6245 11.182 0 6.3156 33.683 L3 37 .9608 28.5190 4 654.2006 12.7590 18.3849 253.1536 93 14.5253 14.2622 5.9296 23.718 45.3134 35.2116 8759.9067 15.7531 22.6695 386.4182 17531.3399 17.6091 7.4140 29 .656 Tower Elevntion Gusse/ Aren (per/nee) Guss er Gusser Grnde Adjust. Factor Adjust. Weight Muir . Double Angle Double Angle L1 120.00- 80.25 L2 80.25-29.83 L3 29 .83 -0 .00 Description 1' 3/4" Lightning Rod (6) EMS DR65 -18-XXP I 12' LP Platform (6) EMS DR65-J 8-XXP I 12' LP Platform (6) EMS DR65-18 -XXP I 12' LP Platform (6) EMS DR65-18 -XXP I 12' LP Platform Description Face or Leg ( 1) 6' Diam. Grid Dish (0 deg AZ) (1) 6' Diam. Grid Dish (180 deg AZ) Thickn ess in Face Offs er or Leg Type D Non e D None D None D None D None Dish Type Grid Grid A1 F a ctor Stitch Bair Stizch Bo/1 A , Spa cing Spacing Dingonals Horizo nta ls in in Discrete Tower Loads Offsets: Azimuth Placemen.I CAA A CAAA Weighr Horz Adjustmenr Fronr Side La tern/ Vert fl deg fl fl' fl' lb fl 00000 120.00 No Ice 0.25 0.00 108 .00 0.0000 120.00 No Ice 40.33 0.00 I 304.00 0 .0000 105.00 No Ice 40.33 0.00 I 304.00 0.0000 90.00 No Ice 40.33 0.00 I 304.00 0.0000 75.00 No Ice 40.33 0.00 I 304.00 Dishes Offset Offsets: Azimuth Elevarion Outside Aperture Weighr Type Horz Adjuszment Diamezer Area Lnternl deg fl fl fr' lb Vert None Worst 60 00 6 .00 No lee 43.85 143.00 None Worst 60 .00 6 .00 No Ic e 29.82 14 3.00 Tower P re s su res -No Ice GH =].JOO PJF Paul J . F ord & Company 250 E. Broad St., Ste. 500 Col um b us, OH 43215 Phone: (614) 221-6679 FAX: (614) 448-4105 Section z K z Elevation ft ft LI 120.00-98 .81 l .262 80.25 L2 80 .25-29.83 54.03 I. I l 2 L3 29 .83 -0.00 14.4 8 0.849 Section z K z Elevat io n ft ft L1 120.00-98.81 1.262 80.25 L2 80.25-29.83 54.03 1.1l2 L3 29 .83 -0 .00 14.4 8 0.849 Job Page 3200 3-0 148 3 of 8 P roject Date 120' Monopol e -A3K02 1, V arsi ty Fo rd ; Colle ge St at io n , T X 11 :04 :0211 /26/03 C lien t Newma rk I T -Mob il e q, Ac F A F A R A 1eg Leg a % c psf ft' e ft ' ft ' fr 37 69.808 A 0.000 69.808 69 .80 8 100.00 B 0.000 69.808 100.00 c 0.000 69.80 8 100.00 D 0.000 69.808 100.00 32 132.936 A 0.000 132.936 132 .936 100.00 B 0.000 13 2 .936 100.00 c 0.000 132.936 100.00 D 0.000 132.936 100.00 25 I 01.942 A 0.000 101 .942 I 0 1.942 100.00 B 0.000 10 1.942 100.00 c 0.000 I 0 1.942 100.00 D 0 .000 101.942 100.00 Tower Pressure -Service G H =].J OO q, A c F AF AR A1eg Leg a % c psf ft' e ft' ft ' ft ' 8 69.808 A 0 .000 69.808 69 .808 100.00 B 0.000 69.808 100.00 c 0.000 69.808 100.0 0 D 0.000 69.808 100.00 7 132 936 A 0.000 l 32.936 132.93 6 100.00 B 0.000 132 .936 100.0 0 c 0.000 I 32.936 100.00 D 0.000 132.936 100.00 5 101.942 A 0.000 I 01.942 101.942 100.00 B 0.000 I 01.942 100.00 c 0 .000 l 01.942 100.0 0 D 0.000 I 01.942 100.00 CAAA Jn Fa ce ft' 0.000 0.000 0.000 CAA A In F a ce fr' 0.000 0.000 0.000 Desig n ed by rt e al C,AA Out F ace ft' 0 .000 0.000 0.000 CAAA Out Face ft ' 0000 0.000 0000 Tower Forces -No Ice -Wind Normal To Face Secti on Add Self F e c,, RR DF DR AE F w Ori. Elevation We ig hr Weig h! a F ace c ft lb lb e ft' lb p lf LI 120.00-0.00 l 681.30 A 1 0.65 I I 1 69.808 l 851.93 46.59 D 80.25 B l 0 .65 l l I 69.80 8 c l 0.65 l l l 69 808 D I 0.65 1 l l 69.808 L2 80.25-0.00 3379.62 A l 0.65 I l l 132 .936 3088. l 3 61.25 D 29.83 B l 0.65 I l I 132 .936 c 1 0.65 I l l 132 .936 D l 0.65 l I l 132 .936 L3 2 9.83 -0 .00 0 .0 0 3767 .9 6 A l 0.65 l I 1 10 1.942 l 820.77 61.03 D B I 0 .65 l I 1 l 0 1.94 2 c l 0.65 I l l l 0 1.942 D 1 0.65 1 I 1 l 01.942 PJF Job Page 32003-0 148 4 of 8 Project Date Paul J . F ord & Company 250 £.Broad St., Ste. 500 120' Monop ol e -A3 K021 , Va rsity Fo rd ; Colleg e St at io n , TX 11 :04 :02 11 /26/03 Columbus. OH 43215 Client Designed by Phone: (614) 221-6679 Newm a rk I T-Mobi le rte al FAX: (614) 448-4105 Section Add Self F e CF RR D r D R AE F w Ori. Elevation We ig ht Weight a F ace c ft lb lb e rr lb pl( S um Weight: 0.00 8828.87 OTM 376217.06 6760.83 lb -ft Tower Forces -Service -Wind Normal To Face Section Add Self F Elevation Weight Weight a c ft lb lb e Ll 120.00 -0.00 1681.30 A 80.25 B c D L2 80.25 -0.00 3 379 .62 A 29.83 B c D L3 2 9.83-0.00 0.00 3767.96 A B c D Sum Weight: 0 .00 8828.87 Load Ve rtical Case Forces lb Tota l Member Self -Weight 8828.87 Wind 0 deg -No Ice 14438.87 Wind 0 deg -Serv ice 1443 8.87 Co mb. No . De a d Only 1 2 3 Dead +Wind 0 deg -No Ice Dead+Win d 0 deg -Servi ce e CF RR DF DR A£ F w Cerf. Face ft' lb plf 1 0.65 l 1 l 69 .808 382.63 9 .63 D I 0 .65 l 1 1 69.808 1 0.65 1 1 1 69.808 1 0.65 1 1 1 69.808 1 0.65 1 1 l 132 .936 638 .04 12.66 D 1 0 .65 1 1 1 132 .936 l 0.65 1 l 1 132.936 I 0.65 l 1 1 132 .936 l 0.65 l 1 I 101.942 376.19 12.6 1 D l 0.65 l l l l Ol.942 l 0.65 1 l l 101.942 l 0.65 l l 1 101 .942 OTM 77730.80 1396.87 lb-ft Force Totals Sum of Su m o/ Sum of Sum of Sum of Torque s Forces Forces Overturning Overtu rn ing x z Moments . M., Moments, M, lb lb lb -ft lb-ft lb-ft 0.00 0.00 0.00 -14 938.09 -11 17429.49 0 .00 0 .00 0.00 -3086.3 8 -230873.86 0 .00 0.00 Load Combinatio ns Description Maximum Member Forces Pag e 5 of 8 J o b 32003-0148 PJF Project Date P au l J . Fo rd & Com p any 25 0 E. Broad St .. S te. 500 Colum bus. OH 43215 Phon e . (61 4) 221 -6679 FAX: (614) 448-4105 120' Monopole -A3K021, Vars ity Fo r d ; College Statio n, TX 11 :04 :02 11 /26/03 C lient Section Elevation Co mponent No. fl Type LI 120 -80.25 Pole L2 80.25 -Pole 29.8333 L3 29.8 333 -0 Pol e location Condition Gov. Load Co mb. Pole Max . Vert I Max. H, 3 Max. H, 2 Max. M, 2 Max. M, I Ma x. Torsion I Mi n . Vert 2 Min .H, 1 Mi n . H, Min.M , Min.M, Min . Torsion Condition Max Tension Max . Co mpression Max. My Max. Vx Max Ten sion Max. Compression Max. My Max . Vx Ma x Ten sion Max . Co mpress ion Max. My Max . Vx Newm ark I T -M o b ile Go v. Load Comb. 3 I 2 2 I 2 2 2 2 Force lb 0.00 -5530.48 -5 107 .4 I -7009.27 0.00 -10302 .7 -I 0001.7 -13019.3 0.00 -14438.8 -14431.1 -14944 .4 7 3 8 7 6 0 Maximum Reaction s Vertical Horizonta l. X lb lb 14438.87 0.00 14438.87 0.00 14438 .82 0 .0 0 1145767 .69 0 .00 0.00 0.0 0 0 .00 0.00 1443 8.82 000 14438.87 000 14438.87 0.00 0.00 0 .00 0.00 0 .00 0.00 000 Desig ned by rt e a l Major Axis Minor Axis Mo m ent Moment /bf!_ /bf!_ 0 .00 -0 .01 0 .00 0 .00 0.00 144868.07 0.00 144868.07 0 .00 0.00 0.00 0.00 0.00 659730.24 0 .00 659730 .24 0.00 0.00 0.00 0.00 0.00 114 5767.69 0.00 1145767.69 Horizom al. Z lb 0 .00 3085.84 14936 .99 14 936.99 0 .00 0 .00 14936.99 0 .00 0 .00 0.00 000 000 Tower Mast Reaction Su mmary load Ver tical Combin at io n lb Dead Only 14438.87 Dead+ Win d 0 deg -No Je e 14438.82 Dead+ Wind 0 deg -Serv ice 14438.87 Sum of Applied Forces Lo ad PX PY Com b. lb lb I 0.00 -1 4438.87 2 0.00 -14438.87 3 0 .00 -14438.87 Shear, Shear, lb lb 0.00 0.00 0.00 -14936.99 0.00 -30 85 .84 Overturn Mom ent. lb-ft in g M., 0 .00 -1145 76 7.69 -2 368 66.45 Solutio n Summary PZ PX lb lb 0.00 0 .0 0 -14 938.09 0 .00 -308 6 .3 8 000 Sum of Re PY lb act ions 14438.8 1443 8.8 14438.8 7 2 7 Overturning Torque Mo ment. M , lb-[!_ lb-[!_ 0.00 0 .0 0 0.00 0 .00 0.00 0.00 PZ %Erro r lb 0.00 0 .000% 14936.99 0.005% 3085.84 0.004% - I I I PJF J ob Page 32003-0148 6 of 8 P aul J. Fo rd & Co mp any P r oject Dat e 250 £. Broad St .. Ste. 500 120 ' Monopole -A3K021 , Varsity Ford ; College Station , TX 11 :04 :02 11 /26/03 Columb us. OH 43215 Cl ien t Designed by Phone: (614) 221-6679 New mark I T -M obile rte al FAX (614) 44 8 -4105 Non-Linear Convergence Results Load Converged? Number Displa cement Force Co mb inacio n of Cycles Tolera nce Tolerance 1 Yes 6 0.00000001 0.00000001 2 Ye s 14 0.00006364 0.00008616 3 Yes 13 0.0000000 1 0.00005993 Maximum Tower Deflections -Service Wind Section Elevacion Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. deg deg L1 120 -80.25 12 .506 3 0.8729 0.0000 L2 83.58 33 -2 9.8333 6.245 3 0.7255 0.0000 L3 34 .75 -0 0.998 3 0.2628 0 .0000 Critical Deflections and Radius of Curvature -Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature Comb. in d e d e t 120.00 3/4" Lightn ing Rod 3 12.506 0 8729 0 .0000 54843 105.00 (6) EMS DR65-18 -XXP I 12' LP 3 9.807 0.8360 0 .0000 18281 Platform 90.00 (6) EMS DR65 -18 -XXP I 12' LP 3 7.255 0.7699 0.0000 9140 Platform 75.00 (6) EMS DR65 -18-XXP I 12' LP 3 4 .996 0.6479 0.0 000 6943 Platform 60.00 ( 1) 6' Diam. G1id Dish (0 deg AZ) 3 3 .124 0.4858 0.0000 6 112 Maximum Tower Deflections -Design Wina Section Elevat ion Ho rz . Gov. Tilt -Twist No. Deflection Load ft in Co mb. d eg deg LI 120 -80 .25 60.421 2 4.2188 0.0000 L2 83.583 3 -29.833 3 30. 183 2 3.5066 0.0000 L3 34.75 -0 4 .829 2 1.2708 0.0000 Critica l Deflections and Radius of Curvature -Design Wind J ob PJF 3200 3-0 148 Page 7 of 8 Projec t Date P aul J. Ford & Comp any 250 £. Broad St., Ste. 500 Columbu s, OH 43215 Phon e: (61 4) 221-6679 FAX (61 4) 448-4105 120' Mo n o p o le -A3K021 , Varsi t y F ord ; Cl ie n t Colleg e Stat ion , T X 11 :04 :02 11 /26/03 N e w ma r k I T-M ob ile Design ed by rt e a l Elevation Appurtenance Gov. Deflectio n Ti lt Tw ist Radiu s of ft 120.00 105.00 90.00 75 .00 60 .00 Seccion No. Ll L2 L3 Section N o. Ll L2 L3 S ection No . LI L2 L3 3/4" Ligh tn in g Rod (6) EM S DR65 -J 8-XXP I 12' LP Platform (6) EMS DR65 -1 8-XXP I 12' LP P latform (6) EMS DR65 -1 8-XXP I 12 ' LP Platform (I) 6' Diam . Grid Dish (0 deg AZ ) Elevation Size ft 12 0 . 80.25 (l ) TP25 .8 98xl 6.25x0. l 875 80.25 -29 .8333 TP37 .7 59x24.7 l 39x0. l 875 (2) 29.8 333 -0 (3) TP44.625x36. I 907x0.25 Land Co mb. in de 2 60.42 1 4.2188 2 47 .385 4.0158 2 35.06 1 3.7020 2 24 .147 3.17 48 2 15. 103 2.4668 Compression Checks Pole Design Data L L. ft ft 39 .75 120.00 53 .75 120 .00 34.75 120 .0 0 Kllr 162.9 l 11.5 91.4 F,, ks i 5 62 8 12.01 I 17.82 7 Curvawre de:< fl 0 .0000 11 4 66 0.0000 3821 0.0000 190 8 0.0000 1446 0.0000 1270 A Actual Allow. p P,, in~ lb lb 14.8195 -5107.4 1 83399.70 21.6496 -I 0001.70 260025 00 35.21 l 6 -l 4431.20 627714.00 Pole Bend i ng Design D ata Elevation Size Actual Acrunl Allow. Ra tio Actual Actual Allow. Ratio M , ft,, F,,, ~ ft lb-ft ksi ksi Fh , M, fi,y Fby ___[iz_ lb -ft ksi ksi F.,, 120 -80.25(1) TP2 5.898x l 6.25x0. I 875 l 44 868. ·19 .084 39.000 0.489 0.00 0.000 39.000 0000 33 80.25 -TP 37.759x24 .7 l 39x0. l 875 659730 . -4 0 .627 34 .080 1.192 0.00 0.000 34.080 0 .000 29 8333 (2 ) 0 0 29.8333 -0 (3) TP44.625x36. l 907x0.25 l 145766 -35 .58i 35.929 0.990 0.00 0 .0 00 35.92 9 0.000 .67 Pole Interaction Design Data Elevation S ize Ratio Ratio Ratio Com b. Allow. Criteria p fb.< f bo S tress S tress ft Pn Fb_, Fb, Ratio Ratio 120 -80.25 (1) TP2 5.8 98x l 6 .25x0 . l 875 0 .061 0.489 0.000 0 .55 1 v l .333 H l -3 V 80.25. TP37.759x24 .7 l 39x0. l 87 5 0 .038 1.192 0.000 29.83 33 (2 ) 29.833 3 -0 (3) TP44 .625x36. l 907x0 .25 0 .023 0.990 0 .0 00 .231 1i/ 1.333 H l -3 V .013 v l .333 Hl -3 V Ratio p P. 0 .061 0 038 0.023 - I I I I PJF Job Pag e 32003-0148 8 of 8 Paul J . Ford & Co mpany Project Date 250 £. Broad St., Ste. 500 120' Monopole -A3K021 , Varsity Fo rd ; College Station , TX 11 :04:02 11/26/03 Columb u s , OH 43215 C lient Designed by Phone: (614) 221-6679 Newmark I T-Mob ile rte al FAX-(6 14) 448-4105 Section Capacity Table S ection Elevation Component S ize Critical p SF*P,,110 .. % Pass No. ft Typ e Elem e111 lb lb Capacity Fail LI 120 -80.2 5 Pole TP25.898x l 6.25x0. l 875 l -5107.41 l l l 171.80 41.3 Pa ss L2 80.25 -29 .8333 Pole TP37 .759x24.7139x0.1875 2 -10001.70 346613.31 92.3 Pass L3 2 9.83 33 -0 Po le TP44.625x36 .1907x0.25 3 -14431.20 836742 .73 76.0 Pass Summary Po le (L2 ) 92 .3 Pass RATI NG= 92 .3 Pass Program Vers ion 2.0 .0.6 8 -11 /! 9/2003 File :G :/TOWER/320_Newmark/32003-014 8 .eri PJF Pole (tm ) -Monopole Design Program Windows Version 3.04.0000 Wed Nov 26, 2003 -11:24:41 am (c) 1993 to 2000 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No ...... : 32003-0148 Design No: Newmark no. 03-372Engineer : RWH Description 120-Ft Monopole -A3K021, Varsity Ford ; College Station, Texas Design..... 90 mph Basic Wind Speed Owner...... T-Mobile Client: Newmark International, Inc. Status..... Final Design Revision: Rev. Date : M 0 N 0 P 0 L E Shaft Shape ..... : Base Dia, DF .... : PT-to-PT, DP .... : Min Bolt Circle . : Base Reactions Moment .............. : Axial Load .......... : Anchor Bolt Details Number of Bolts ...... Bolt Diameter ........ Bolt Type ............. Y-Distance ............ Mom. of Inertia .. ..... Bolt Tension, T ...... Allowable Tension .... Bolt Compression, c .. Base Plate Details Plate Moment, MPL ... : Bend Plane, W ....... : Plate Thickness, t .. : Plate Width ......... : Plate Steel ......... : Gross Weight ........ : Net Weight .......... : Allowable Stress .... : Actual Stress ....... : Act./Allow Ratio .... : B A S E B A S E P L A T E D E S I G N D E T A I L S 18 Sided Polygon 44 .62S Inches 4S.313 Inches Sl. 62S Inches Stress Increase ... : 1.333 Factor Base Plate Shape .. : Round Use Bolt Circle ... : Sl.SOO Inches DESIGN 129S.91 Ft-Kips lS.01 Kips DESIGN 8 2.2SO Inches #18J ASTM A61S 3 266S.14 In "4 lS0.61 Kips 194.81 Kips 1S2.49 Kips DESIGN S33.72 In-Kips 17.70 Inches 1.902 Inches S6.87S Inches ASTM AS72 GRADE SO (SO KSI) 1370.30 Lbs 1047.SO Lbs 49.99 Ksi 49.99 Ksi 1. 00 USER 1300. 00 Ft-Kips 16.00 Kips USER 8 2.2SO Inches #18J ASTM A61S 3 26S2.2S In"4 lSl.46 Kips 194.81 Kips 1S3.46 Kips USER S27.Sl In-Kips 17.70 Inches 2.000 Inches S7.SOO Inches ASTM AS72 GRADE SO (SO KSI) 1472.80 Lbs 1133.30 Lbs 49 .99 Ksi 44.69 Ksi 0.89 P L A T E D E S I G N S U M M A R Y USE FOLLOWING SPECIFICATIONS: Plate Thickness ..... : Plate Width/Diameter : Plate Weight ........ : 2.000 Inches S7.SOO Inches 1.473 Kips Number of Bolts .. . (Round) Bolt Circle ...... : Bolt Diameter .... : Bolt Type ........ : 8 Sl. SO Inches 2 .2S Inches #18J ASTM A61S PJF Pole (tm) -Monopole Design Program Windows Version 3.04.0000 Fri Nov 21, 2003 -3:21:07 pm (c) 1993 to 2000 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No ...... : 32003-0148 Design No: Newmark no. 03-372Engineer : RWH Description 120-Ft Monopole -A3K021, Varsity Ford; College Station, Texas Design..... 90 mph Basic Wind Speed Owner...... T-Mobile Client: Newmark International, Inc. Status..... Final Design Revision: Rev. Date : S U M M A R Y 0 F C U R R E N T C A I S S 0 N D E S I G N Diameter (ft) ...... 6.00 Compression (kips) : 16.00 Friction S.F . ...... 2.00 Min. Depth (ft) .... 16.00 Horizontal (kips) 18.00 Lateral S.F . ........ 2.00 Depth Used (ft) ..... 16.00 Uplift (kips) . . . . .. 0.00 Concrete S.F . ....... l. 30 Rebar Area (in "'2 ) .. 21.84 Moment (Ft-kips) . . 1300.0 Concrete F'c (psi) : 3000.0 Rebar Used ........ : (14)#11 Full Cohesion (ft): 18.00 Steel Cover Water at (ft) ....... 12.00 Rock at (ft) .. ....... 99.00 SOIL PROFILE Soil Layer Unit Ult. Skin Allowable Friction Passive Layer Thickness Weight Friction Bearing Angle- (ft) (pcf) (psf) (psf) (deg) l 3.00 110. 00 0.00 0.00 0.00 2 3.00 130.00 0.00 0.00 0.00 3 6.00 130.00 0.00 0.00 0.00 4 5.00 64.60 0.00 5000.00 28.00 5 5.00 64.60 0.00 6500.00 32.00 6 10.00 64.60 0.00 7000.00 LATERAL / MOMENT CAPACITY (CHECK) Caisson D_:i,.ameter (ft) ............................ . Height Above Grade (ft) .......................... . Depth Below Grade (ft) ........................... . Concrete Volume (CY) ............................. . Applied Moment From Loads (Working), Mwork(Ft-kip): Resisting Moment From Soil (Ult), Mult(Ft-kip) ... : Moment S.F. (Mult I Mwork) ....................... : Applied Horizontal ~9-?q (Working), Hwork (Kips) .. . Horizontal pofi, Re~rsiance (Ultimate), Hult (Kips): Horizontal S.F. (Hult I Hwork) ................... . Center of ·Rotation (from grade) (ft) ............. : Inflection Point (Max Design Moment Location (ft) Maximum Factored Design Moment for Reinf. (Ft-kip): Area Steel Required From Loads (in"'2) ............ : ACI Minimum Steel (0.5%) (in "'2) .................. : Area Reinf. Steel Provided (in "'2) ................ . UPLIFT CAPACITY CHECK : Actual Uplift on Caisson (Kips) .................. : Allowable Uplift Capacity (Kips) ................. : COMPRESSION CAPACITY CHECK : Actual Compression on Caisson (Kips) ............. . Total Compression (Includes Concrete Wt.) (Kips) .. Allowable Compression Capacity (Kips) ............ : 0.00 Phi Coeff.- l. 000 l. 000 l. 000 2.770 3.255 l. 000 Min Design 6.00 0.50 16.00 17.28 1494.40 3033.02 2.03 18.00 42.30 2.35 10.30 3.80 1780.28 12.00 20.36 21. 84 0.00 50.34 16.00 40.74 141.37 (in) ... 3.00 Cohesion KP (c) (psf) 0.00 2500.00 3000.00 0.00 0.00 2500.00 Actual Design 6.00 0.50 16.00 17.28 1494.40 3033.02 2.03 18.00 42.30 2.35 10.30 3.80 1780.28 12.00 20.36 21. 84 0.00 50.34 16.00 40.74 141.37 ------------------------------------------------------------------------------------ CAISSON DESIGN: USE: 6.00 ft Diameter X 16.50 ft Long (Concrete Volume = 17.28 CY) Reinf: (14)#11 Vert, w/Closed Ties: (12)#5 @6.0 11 , remaining ties @18.0" (ASTM A615) ------------------------------------------------------------------------------------ n NEVV1'/\~RK INFRASTRUCTURE SOLUT I ONS 10 2 SENTRY DR IVE MANSFIELD , TX 76063 (800 ) 726-2726 Fax : (8 17) 47 3-1454 www .new mark.c om PAUL J. FORD AND COMPANY STRUCT U R A L ENGINEERS 250 East Broad Street , Suite 500 , Col umbu s, Ohio 43215 (61 4) 221 -6679 Fa x: (614 ) 448-4105 www.PJFw eb .com " ~ § ::> ~ g 0 0 N ..., / ..., 0 0 N 120·-o · 105' -o· 90·-o· 83' -7' 75'-o" 60 '-0" ~ 34'-9" ..., / u z -, ~ 0 ~ a: ~ z -, ~ ~ z I ~ ..., ~ ~ 0 z 0 3- Vl " z ~ ;i. a: ! .:; I[_ 3/16" X 39 .75' (Fy=65) (EST WT = 1.68 1 KIPS) t SP LICE LENGTH MIN = 35 .00" DESIGN = 40 .00" MAX = 44 .00" I[_ 3/16" X 53. 75' (Fy=65) (EST WT = 3.379 KIPS) -t SPLICE LENGTH MIN = 53 .10" DESIGN = 59 .00" MAX = 64.90" I[_ 1/4" X 34 .75 ' (Fy=65) (EST WT = 3. 768 KIPS) JOB DATA Po e 1 o f 2 Job No. '""'B~y~---R-W-H--------< De s ign No. 1--=--,--,--,.---,,,....-~---------i Do te Ch k d By Rev . No . Pole 120-FT MONO POLE 32003-0148 NEWMARK 603-372 11-~6 -2003 Rev. Dote Site A3K02 1, VARSI TY FORD: CO LLEGE STATION, TEXAS Owner T -MOBILE Re f . No. 32003-0037 Design 110 MPH DESIGN WIN D VELOCITY 3-SECO ND GUST ACCORDING TO THE INTERNATION AL B UILDING CODE 2000 L 0 A D C A S E S CASE 1 11 0 MP H WITH NO ICE CASE 2 50 MP H WITH NO ICE 3-SECOND GUST DESIGN WINO OPERAT ION AL WINO ·POLE SPECIF I CATIONS Pole Shope T pe: 18-SIOEO POLYGON Toper : 0 .242708 IN FT Sha ft Stee l : AS TM A572 GRADE 65 Bo se PL Stee l : AS TM A572 GRADE 50 50 KS I An cho r Bolts: 2 1 4 0 x 8 -0 LONG 18J ASTM A615 GRADE 75 ANTENNA L I ST No . Elev. Description TOP 3 4 LIGHTNING ROD 1-6 TOP (6) EMS DR65 -18-00D PL20 PANEL TOP 12' LOW PRO FILE PLATFORM 7-12 105 .00 (6) EMS RR65 -18-00DP PCS PANEL 105 .00 12' LOW PROFI LE PLATFORM 13-18 90.00 (6) EMS RR65-18-00DP PCS PANEL 90 .00 12' LOW PRO FILE PLATFORM 19-24 75 .00 (6) EMS RR65-18-00DP PCS PANEL 75 .00 12' LOW PRO FILE PLATFORM ~''''' 25 60 .00 (1) 6' DIAM. GRID DISH (2 GHz ) --~OF T~.i;~\\ 26 60 .00 1 6' DIAM . GR ID DISH 180 DEG . Al.. -·········~~ ' STEP BOLTS FULL HEIGHT FROM 9' -6 ABOVE BASE PLATE. ; • ····.* II ANTENNA FEED LINES RUN INSID E OF PO LE. ~,: f •••••••••;!!.~ .. :.KiRK 0REED H!.'~~---·~ ••••••·•••·••·•··• • ii ···~· :~"" ".-a")fe1i·. 89916 Q .··~ 1_"1, e,o~·~!CENS~.·~~ " '~s ·········· ~ - 110 MPH WI ND Latera l Rotat i on Lateral Rotation Elev ation Def lec ti on (sway) Def lection (sway ) (I nches) (degrees) (Inches) (degrees ) TOP 60.5 4.219 12.5 0.873 60 .0 ' 15 .1 2 .467 3 .2 0.486 t!QI£; MONOPO LE WAS DESIGN ED TO MEET MAXIM UM TW IST AN D SWAY REQU IRE MENT S OF 4.6CT FOR A 6.o ·~ DISH (2 .0 GHz) AT ELEV. 60 .0' WIT H A 50 MPH WIND. SHAFT SECT I ON DATA Shaft Section Plate Lop Diameter Across Fl a ts Length Th ickness Splice (inches) Secti on (feet) (in .) (in.) @ Top @ Bo ttom 1 39 .75 0 .1875 40 .00 16.250 25 .898 2 53.75 0 .1875 59 .00 24.714 37 .759 3 34 .75 0.2500 36.19 1 44.625 NOTE : DIMENS IONS SHOW N DO NO T INCLUDE GALVANIZING TOLERANCES BAS E REACTIONS FOR FDN DES IGN MOMENT = 13 00 ft-kips SHEAR = 18 kips BASE I[_ 2" X 57 .500" ROUND W/(8) 2.25"0 ANCHOR BO LTS EQUALLY SPACED ON 5 1.500" B.C. WITH MIN . 7'-0" EMB ED MEN T INTO PIER (W/NUTS & TEMPLATE PLAT E 0 BOT.) AXIA L = 16 kips TIGHTEN ANC HOR NU TS TO AISC SNUG TIGH T CONDITION . JYLf\ 44 .625" ACROSS FLATS l}tl-• 01 i .. ti .. [j.f i: lb 'Pfl'\ "DN EVV1'/\.A.RK INFRASTRUCTURE SOLUTIONS 10 2 SE NTRY DRIV E MANSFIELD , TX 76063 (8 00) 726-2726 Fax: (81 7) 473-1454 www .n ewmark.com POLE SHAFT & BASE PL. HE AVY HE X NU T 3" GAP (NO GROUT) I I- (.'.) z w .....J . <D I <D 3" CLR 12'-o"S:Z w.T. ct_ POLE & FOUND ATION 2" CLR REM #5 TIES @ 18 " C/C 2'-0" MIN LAP 0 N (1 4)-#1 1 VERT REIN F FULL HEIG HT a::: .....J u 6'-0"0 SHA FT CA ISSON (DRILLED PAUL J. FORD AND COMPANY STRU CT URAL ENGINEERS 250 East Broad Street, Suite 500 , Columbus , Oh io 43215 (614 ) 221-6679 Fax : (614) 448-4105 www.PJFweb.com JOB DATA Po e 2 o f 2 Job No. <--~--------< By RWH Design No. ....,C~h~k~d~B-..,,.,...,il -----l Dole Y 11 Rev . No. Pole 1 20-FT MONOPO LE 32003-0148 NEWMARK NO . 03-372 11-26-2003 Rev. Dote Site A3K021. VARS ITY FORD: COLLEGE STATION, TEX AS Owner T-MOBILE Ref. No. Des ign 11 0 MP H DESIGN WIND VELOCITY 3-SECOND GUS T AC CO RD ING TO THE IBC 2000 NOT ES : 1. ALL CONCRETE SHA LL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PS I AT 28 DAYS . CONCRETE SHA LL BE AIR ENTRAINED (6±1.5%). CONCR ETE SHALL HAVE A MAXIMUM WATER/CEMENT RATIO OF 0.46. ALL CONCR ETE WORK SHA LL BE IN ACCOR DANCE WITH "THE BUILDING CODE REQUIREM EN TS FOR REI NFORCED CONCRETE", AC I 318 , LATEST EDITION. FOUNDATION INSTALLATION SHALL BE IN ACCORDA NCE WITH AC ! 336, "STANDARD SPECIFICATIONS FOR THE CONSTRUCTION OF DRILLED PIERS", LATEST ED ITI ON . 2. REIN FORC ING STEEL SHALL CONFORM TO THE REQUIREMENTS OF AS TM A-61 5 (GRADE 60) EXCEPT THAT CAISSON TIES MAY BE ASTM A-615 (GRAD E 40 ). ALL RE INFORCING DET AI LS SHA LL CONFORM TO "MANU AL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTU RES", AC! 315, LATEST EDITION , UNLESS DETAILED OTHERWISE ON THI S DRAWING . 3. SE E PAGE 1 FOR ANCHOR BO LT QUANT ITY, SIZE, LENGTH, AND BO LT CIRCL E. 4. TOTAL CONCRET E = 17.5 CUBIC YARDS. 5. FO UNDATION DES IGN IS BASED UPON GEOTECHNICAL EXPLOR ATION REPOR T PREPARED BY: REPORT NO .: DATED: TERRA-MAR HE 02-128 09-1 0-2002 6. CONTRACTOR SHALL READ THE GEOTECHNICAL REPORT AN D CONSULT THE GEOT ECH NICAL ENGIN EER AS NECESSARY PRIOR TO CON STRUCTION . 7. GEOTECHN ICA L REPORT INDICATES GROUND WATER WAS ENCOUNTERED AT 12'-0" BELOW GRADE. 8. THE FOU NDATIO N WAS DESIGNED USING THE FOLLOWING SERVICE LOADS: MOMENT : SHE AR: AX IAL: 1300 FT -KIP S 18 KIPS 16 KIPS PIER) FOUNDAT ION 1 Job PJF 32003-0148 Page 1 of 8 Project Date Paul J. F ord & Company 2 5 0 E. Broad St., Ste. 500 Columb us , OH 43215 Phone: (614) 221 -6679 FAX (6 14) 448-4105 120 ' Monopole -A3K021 , Va rsi ty Ford ; Colleg e Stat io n , TX 11 :04 :02 11 /26/03 Client Des ign ed by Newmark I T-Mob ile Towe r Input Data There is a pole sec tion . This tower is designed u sing the TWEIA-222-F standard. The followin g design criteria apply: A 110 mph 3-second p eak g ust ASCE 7-02 wind profi le u sed (expo sur e C). Wind importance factor is 1.00 . Deflections calcul ated u si ng a wind speed of 50 mph . A non-lin ear (P-de lta ) anal ys i s wa s u sed. Pressures are calculated at each section . Stress rati o u sed in pol e design is 1.333. Local bendin g stresses due to climbing loads and feedline supports Options are not considered. Consider Moments -Legs Con sider Moments -Hori zontal s Con sider Moments -Diagonals Use Moment Magnificati on Di stribute Leg Load s As Uniform Assume Legs Pinned Feedlin e Bund les As Cylinder T reat Use A Calc u Cons id ../ Use Code Stress Ratios ../ Use Code Safety Factors -Guys Escalate lee Always Use Max Kz ../ Use Special Wind Profil e ../ Include Bolts In Member Capac ity ..J Leg Bolts Are At Top Of Section ..J Secondary Horizontal Braces Leg ../ Assume Rigid Index Pl ate Use C lear Spans For Wind Area Use Clear Spans Fo r K.Ur Reten s ion G uys To In itial Tension Bypas s M ast Stabil ity C hecks Use Azimuth Dish Coeffi cients Project Wind Area of Appurt. Autocalc Torq ue Arm Areas SR Members Have C ut End s SCE 10 X -Brace Ly Rules lat e Redundant Bracing Forces ../ SR Le ../ All Le Offset er Feed line Torqu e g Bo lts Resist Comp re s s ion g Panels Have Same All owab le Girt At Foundation Poles e Shear-Torsion Int eraction Jnc lud Alway ../ Use T s Use Sub-Critical Flow op Mounted Sockets Tapered Pole Section Ge ometry Section Elevation Section Splice Num ber Top Bottom Wa ll Bend Pole Grade I Ll 120.00-80 .25 L2 80.25-29 .83 L3 29 .83 -0.00 Section Tip Dia. in Ll 16.5007 26.2975 L2 25 .9167 Length Length of Diamete r Diam eter 11ickn ess Radius I I Sides in in in in 39.7 5 3 .33 18 16.2500 25.8980 0.1875 0.7500 53.75 4.92 18 24 .7139 37.7590 0 .1 875 0 .75 00 34 .75 18 36.1907 44 .6250 0.2500 1.0000 Tapered Pole Propert ies Area r c . ' . ' in in m · In 9.5592 311.5911 5 .7022 8.2550 15 .3010 1277.8422 9 .1272 13 .1562 14 .5963 110 9.3009 8.7069 12.5547 l lC in 3 37.745 7 97.1286 88.3575 J . , zn 22 623.59 2557.36 2220.06 57 14 Jt /Q w in 1 in 4 .7805 2.5300 7.65 19 4.2280 7.2995 4.0197 A572 -65 (6 5 ksi) A572 -65 (65 ksi ) A572 -65 (65 ksi) wi t 13.493 22.55 2 1.438 rte al - I I I I Page Job PJF 32003 -0148 2 of 8 Paul J. Ford & Comp any Project Date 250 E. Brand St .. Ste. 500 ·columbus , OH432/5 Phone : (614) 221-6679 FAX.· (614) 448-4105 120 ' Monopole -A3K021 , Varsity Fo rd ; College Station , TX 11 :04:02 11/26/03 Cl ie nt Section Tip Din Area r c in . , . ' in in tn -111 38.34 15 22.3597 3987.6887 13.3379 19.18 16 L3 37.9608 28.5190 4654 .200 6 12.7590 18.3849 45.3134 35 .2116 8759.9067 15.7531 22.6695 Newmark I T -Mo bile !IC J in 3 . ' 111 207 .8917 7980.6245 253.1536 9314.5253 386.4182 1753 1.3399 ItlQ w in J in 1 1.1 820 6.3156 14.2622 5.9296 17 .6091 7.4140 Designed by rte al wi t 33.683 23 .718 29 .656 Tower Elevation Gu sset Gusset Gusset Grade Adjust. Factor Adjust. We ight Mull. Do uble Angle Double Angle Area (per/ace) fl LI 120.00- 80.25 u 80.25-29.83 L3 29 .83-0.00 Description f1 2 314" Lightning Rod (6) EMS DR65-l8 -XXP I 12 ' LP Platform (6) EMS DR65-18-XXP I 12' LP Platform (6) EMS DR65-l8-XXP I 12' LP Pla tform (6) EMS DR65-J 8-XXP I 12' LP Platform Description Face or leg (I) 6' Diam Grid Dish (0 deg AZ) (1) 6' Diam Grid Dish (180 deg AZ) Thicknes s in Face Offset or Leg Typ e D None D on e D None D None D Non e Dish Type Grid Grid A1 Factor Stitch Bolt A , Spacing Diag onals in Discrete Tower Loads Offset s: Azimuth Placemen.I CAA A Horz Adju stm ent F ront lateral Vert ft deg ft ft" ft 0 .0000 120.00 o Jee 0.25 0.0000 120.00 No Jee 40.33 0.0000 105 .00 No Jee 4 0.33 0 .0000 90.00 No Jee 40 .33 0.0000 75.00 No Ice 40 .33 Dishes Offset Offsets : Azimuth Elevation Ou tside Ty pe Horz Adjustm ent Diameter lateral deg ft ft Vert None Worst 60.00 6 .00 No Je e None Worst 60.00 6 .0 0 No Jee Tower Pressures -No Ice '--~~~~~~~~~~~~~~~~~~- GH =].JOO Stitch Bolt Spacing Horizon en ls in CAAA Weight Side ft" lb 000 10 8.00 0.00 1304 .00 0 .00 1304 .00 0.00 1304.00 0.00 1304.00 Aperture Weight Are a ft" lb 4 3 .85 143.00 29.82 143 .00 , PJF Paul J. F ord & Company 250 £. Broa d St .. S te. 500 Co lumbus. OH432 15 Phone: (614) 221-6679 FAX (614) 448-4105 Section z Kz Elevation ft ft Ll 120.00 -9 8.8 1 l .262 80 .25 u 80 .25-2 9.83 54.03 1.112 L3 29.83 -0 .00 1448 0.849 Section z Kz Elevation ft ft LJ 120 .00-98 .81 1.262 80.25 u 80.25-2 9.83 54 03 1.112 L3 29.83 -0 00 1448 0 .849 Job Page 32003-0 148 3 of 8 Project Date 120' Monopol e -A3K021, Varsity Ford ; College Station , T X 11 :04:02 11 /26/03 Client Newmark I T-Mobile q, Ac F A F A R A1eg Leg a % c psf ft' e ft' ft' ft' 37 69.808 A 0.000 69 .808 69.8 0 8 100 .00 B 0.000 69 .808 100.00 c 0.000 69.808 100.00 D 0.000 69 .808 100 .00 32 132.936 A 0.000 132.936 132 .936 100.00 B 0.000 132.936 100.00 c 0.000 132.936 100.00 D 0.000 132.936 100.00 25 101.942 A 0.000 10 1.942 101.94 2 100.00 B 0.000 101.942 100.00 c 0.000 101.942 100.00 D 0.000 101 .942 100.00 Tower Pressure -Service GH = J.100 q, Ac F AF A• A1eg Leg (7 % c psf fr' e ft' .ft ' ft ' . 8 69.808 A 0.000 69.808 69.808 100.00 B 0000 69 .808 100 .00 c 0.000 69.808 100.00 D 0.000 69.808 100 .00 7 132 936 A 0.000 l 32.936 132.936 100.00 B 0 .000 132.936 100.00 c 0.000 132.936 100 .00 D 0000 132.936 100 .00 5 10 1.942 A 0.000 101.942 l 01.942 100.00 B 0.000 101.942 100.00 c 0000 101.942 100.00 D 0 .000 l 01.942 100.00 CAA A Jn Face ft' 0.000 0.000 0.000 C~A Jn Face ft' 0.000 0.000 0 .000 Designed by rte al CAAA Out Face ft' 0.000 0.000 0.000 CAAA Out Face ft' 0000 0.000 0.000 Tower Forces -No Ice -Wi n d Norma l To Face Section Add Self F e CF RR Dr D. A E F w Ctr/. Elevation Weight Weight (7 Face c ft lb lb e ft ' lb pl( Ll 120.00-0 .00 168 1.30 A 1 0.65 l I I 69.808 1851.93 46.5 9 D 80.25 B 1 0.65 1 1 1 69 .808 c 1 0 .65 l 1 1 69 .808 D 1 0.65 1 1 I 69.808 L2 80 .25 -0.00 3379 .62 A l 0.65 l 1 1 132.936 3088.13 61 .25 D 29.83 B 1 0.65 1 1 1 132 .936 c 1 0.65 1 1 1 l 32.936 D 1 0.65 1 1 1 132 .936 L3 29 .83 -0.00 0.00 3767.96 A 1 0.6 5 1 1 1 101.942 1820 .77 61.03 D B 1 0 .65 1 1 1 l 01.942 c l 0.65 l l 1 l 01.942 D l 0 .65 l l I 10 1.942 Page Job PJF 32003-0148 4 of 8 Paul ]. F ord & Company P r oj ect Date 250 £. Broad St .. Ste. 500 Colum bus. OH 43215 Phone: (614) 221 -6679 FAX (6 14) 448-4 105 120' Monopo le -A3K021 , V a rsit y Fo rd ; C oll e ge Sta tio n , TX 11 :04 :0211 /26/03 C l ient Section Add Self F e Elevation Weig h t Weight a c fi lb lb e S um Weight: 0.00 8828.87 New mark I T -Mob ile CF RR D F D. AE rr OTM 376217.06 lb-ft F w lb If 6760 .83 Desi g ned by rt e al Ctr/. Face Tower Forces -Service -Wind Normal To Face Sec1io11 Elevation fi LI 120.00- 80.25 L2 80.2 5- 29 83 L3 29 .83 -0.00 Sum Weight: Load Case Add Weig ht lb 0 .00 0.00 0.00 0.00 Total M ember Self-Weight Wi nd 0 deg -No Ice Wind 0 deg -Serv ice Comb. N o. Dead Only Self F Weight a c lb e 1681.30 A B c D 3379.62 A B c D 3767.96 A B c D 8828.87 Ve rzi ca/ Forces lb 8828.87 144 38.87 I 4438 .87 I 2 3 Dead+Wind 0 d eg -No Ice Dead+ Wind 0 deg -Service e CF R. DF DR A E {11 I 0.65 I I 1 69.808 I 0 .65 I I 1 69 .808 1 0.65 I I 1 69.808 1 0.65 1 I 1 69.808 1 065 I 1 1 132.936 I 0 .65 I 1 I 132 .9 36 1 0.65 1 I I 132 .936 1 0.65 I 1 I 132.936 1 0 .65 1 I 1 101.942 1 0.65 I 1 1 101.942 I 0.65 1 I I 101 .942 1 0.65 I I 1 101.942 O TM 77730.80 lb-ft Force Totals Sum o/ Su m of Su m o/ Forces Forces Overturning x z Mo mems. M, lb lb lb-ft 0 .00 0.00 -I 4938.09 -I I 174 2 9.49 0 .00 -3086.38 -2 30873 .86 Load Combinations Description Maximum Member Forces F lb 382.63 6 38.04 376.19 1396 .87 Su m of Overturning Mo menls. M, lb-ft 0 .00 0.00 0.00 w Ctr/. Face pl{ 9.6 3 D 12.66 D 12.6 1 D Su m a/Torques lb-t 0.00 0.00 , Job PJF 320 03 -0148 Page 5 of 8 Project Date Paul J. F ord & Company 250 E Broad St .. Sze. 500 Columbus. OH43215 Pho11 e. (614) 221-6679 FAX (614) 448-4105 120' Monopol e -A3K 021 , Varsi ty Ford ; Co C lient lie ge Station , T X 11:04 :02 11/26/03 Secrio11 Elevnrio11 Compone11 1 No. ft Type LI 120 -80.25 Pole L2 80.25 -Pole 29.8333 L3 29.8333 -0 Pole Locnzion Condirion Go v. Load Comb. Pol e Max. Vert 1 Max. H, 3 Max. H, 2 Max. M , 2 Max . M, 1 Max. Torsion I Min . Vert 2 Min . H, Min . H, Min .M , Min .M, Min . Torsion Newma rk I T-Mob il e C ondition Gov. Force Load Co mb. lb Max Tension 3 0.00 Max . Com pression I -5530.48 Max. My 2 -5107.41 Max . Vx 2 -7009.27 Max Tension 1 0.00 Max. Compression I -1 0302 .77 Max. My 2 -] 0001.73 Max. Vx 2 -13019.38 Max Tension 1 0.00 Max . Com pression 1 -14438.87 Max . My 2 -144 31.16 Max . Vx 2 -14 944 .40 Maximum Reactions Vertical Horizontal. X lb lb 14438.87 0.00 14438.87 0.00 14438.82 0 .00 1145767.69 0.00 0 .00 0.00 0 .00 0.00 14438.82 0.00 14438.87 0.00 14438 .87 0.00 0.00 0.00 0 .00 0.00 0 .00 0.00 M ajorAxis Mo m e/1/ lb-ft 0.00 0.00 0.00 0 .00 0.00 0.00 0.00 0.00 0.00 0 .00 0.00 0 .00 ·izo11wl, Z lb 0.00 085.84 3 14 14 936 99 936.99 0.00 0.00 14 936 .99 0.00 000 0.00 0 .00 0.00 Des ig n ed by rte a l Mi11orAxis Mo me/l/ lb-ft -0.01 0.00 144868.07 144868.07 0.00 0 .00 6597 30.24 659730.24 0.00 0.00 1145767.69 1145767.69 Tower Mast Reaction Summ ary Load Ve rtical Shear, Shear, Overturnin g Overl urni11g Torq ue Combinntion Momeni, M , Mome11 1. M , lb lb lb lb-(i lb-(i lb~(i Dead Only 14438.87 0.00 0.00 0.00 0.00 0.00 Dead+ Wind 0 deg -No lee 1443 8.82 0.00 -14 936.99 -1145 76 7.69 0.00 0.00 Dead+W ind 0 deg -Service 14438.87 0.00 -3085.84 -23686645 0.00 0 .00 Solut ion Summary Sum of Applied Forces S um of Reaczions Load PX PY PZ PX PY PZ %Error Comb. lb lb lb lb lb lb 1 0.00 -14438.87 0 .00 0.00 14438.87 0.00 0.000% 2 0.00 -14438.87 -14938.09 0.00 1443 8 .82 14936.99 0.005% 3 0 .00 -14438 .87 -3086.3 8 0.00 14438.87 3085.84 0.004% - I I I Pa ge J o b PJF 32003-014 8 6 of 8 Project Date P aul J. F o rd & Co m pany 250 E. Broad St .. Se e. 500 Columbus. OH 43215 Phone. (614) 221-6679 FAX: (614) 44 8 -4105 120' Mon o po le -A3K0 2 1, Varsity Fo rd ; College Stat io n, TX 11 :04 :02 11 /26 /03 Cl i ent New mark I T -Mob il e Non-Linear Convergence Results '--~~~~~~~~~~~~~~~~~~ Load Converged ? Number Displa cem ent Force Combinacion of Cy cles Tolera n ce Tolerance 1 Yes 6 0.00000001 0.00000001 2 Yes 14 0.00006364 0.00008616 3 Yes 13 0.00000001 0.00005993 Maximum Tower Deflectio"ns -Service Wind Section Elevation Horz. Gov. Tilt Twist No. Dejleczion Lo ad fr in Comb . deg deg Ll 120-80.25 12.506 3 0.8729 0 .0000 L2 83.5 83 3 -·2 9.8 333 6.245 3 0 .7255 0 .0000 L3 34 .75-0 0 .998 3 0.2628 0 .0000 Designed b y rte al Critical Deflections and Radius of Curvature -Service Wind Elevat ion Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvatu re fr Co mb. in de de ( 120 .00 3/4" Lightni ng Rod 3 12 .506 0.8729 0.0000 54843 105.00 (6) EMS DR65-18-XXP I 12' LP 3 9.807 0.83 60 00000 18281 Platform 90.00 (6) EMS DR65-18-XXP I 12' LP 3 7.255 0 .7699 0 .0000 9140 Platform 75.00 (6) EMS DR65 -l 8-XX P I 12 ' LP 3 4.996 0.6479 0.0000 6943 Platform 60.00 (1) 6' Diam. G1;d Dish (0 deg AZ) 3 3.124 0.4858 0.0000 6112 Maximum Tower Deflections -Design Wind '--~~~~~~~~~~~~~~~~~~ Section Elevation Horz. Gov. Tilt Twist No. Dejleczion Load fr in Co mb. deg d eg Ll 120 -80 .25 60.421 2 4.2 188 0 .0000 L2 83 .58 33 -29 .8333 30 .183 2 3 .5066 0 .0000 L3 34.75 -0 4 .829 2 1.2708 0.0000 Critical Deflections and Radius of Curvature -Design Wind Page 7 of 8 PJF 32 00 3-0148 Job Project Date Paul J. Ford & Company 250 E. Broad St., Ste. 500 Columbu s , OH 432 15 Phone: (614) 221 -66 79 FAX (6 14) 448-4105 120' Monopole -A3K021 , Varsity Ford ; College Station , T X 11 :04 :02 11 /26/03 Client Designed by Newmark I T-Mob ile rte a l Elevation Appurtenance Gov. Deflection Tilt Twist Radius of t 120 .00 105 .00 90.00 75.00 60.00 Section No. L1 L2 L3 Section No . L1 L2 L3 S ection No. L1 L2 L3 3/4" Lightning Rod (6) EMS DR65-18-XXP I 12' LP Platform (6) EMS DR65-l 8-XX P I 12' LP Platform (6 ) EMS DR65-1 8-XXP I 12' LP Platform (I ) 6' Diam . Grid Dish (0 deg AZ) Elevmion Size ft 120 -80.25 (1) TP25.89 8xl 6.25x0. l 875 80 .25 -29.8 33 3 TP 37 .7 59x24 .7139x0.1875 (2) 29.8333 -0 (3) TP44.625x36 . l 907x0.25 Load Comb. in deg 2 60.421 4 .2188 2 47.385 4.0158 2 35.06 1 3.7020 2 24.147 3.1748 2 15 .103 2.4668 Compression Check s Pole Design Data L L. Kll r ft ft 39 .75 120.00 162 .9 53.75 120 .00 111.5 34 .75 120.00 9 1.4 F " ks i 28 5.6 l 2.0 11 17.8 27 Cu rvature deJ!. fi 0.0000 11466 0.0000 3821 0.0000 1908 0.0000 1446 0 .0000 1270 A Acwnl Allow. p P., in ~ lb lb 14.8 19 5 -5 10 7.41 83399.70 2 l.64 96 -l 0001.70 260025.00 3 5.2 116 -14431.20 627714 .00 Po le Bend i ng Des ig n D ata Elevmion Size Actual A cw.al Allow. Ratio Acwal Aczua/ Allow. Ratio My fny Fby _A_ lb-ft ksi ksi F b,, M, f bx F bx ft lb-ft ksi ksi _k:_ Fn , 120-80.25 (l) TP25.898 x l 6.25x0 .1875 144868. -19 .084 39.000 0 .489 0 .00 o.oo o 39.000 0.000 33 80.25 -TP 37.759x24 .7139x0.1875 659730. -40 .627 34.0 80 1.192 0.00 0.000 34.080 0.000 29.8 333 (2) 00 29 .8 333 -0 (3) TP44 .625x36. l 907x0.25 1145766 -35.581 35.929 0990 0 .00 0000 3 5.92 9 0.000 .67 Po le Intera cti on Des i gn Data E/eva1ion Size Ratio Ratio Razio Com b . Allow. Crizeria p fh _, fh ,, Szress S1ress ft Pa F bx Fn •· Ra1io Rmio 120 -80.25 (1) TP25.898x l 6.25x0 . l 875 0 .061 0.489 0 .000 0.551 v 1.3 33 HJ-3V 1.2 3 1 v 1.333 Hl-3V 1.013 v l .333 Hl-3 V 80 .25 -TP 37.7 59x24.7139x0. l 875 0 .03 8 1.192 0 .000 29.8 333 (2) 29 .8333 -0 (3) TP44.625x36. l 907x0 .25 0 .023 0.990 0.000 Ratio p Pa 0 .061 0.038 0.023 ~ I I I I Page Job PJF 32003-0 148 8 of 8 Paul J. Ford & Company 250 E. Brand St .. Ste. 500 Columbus, OH 43215 Pho ne : (614) 221-6679 FAX (614) 448-4105 Project Date 120 ' Monopole -A3K021 , Vars ity Ford ; College Station , T X 11 :04 :02 11/26/03 Cl ie nt Newmark I T-Mobile Section Capacity Table S ection Elevation Component Siz e Critical p No . ft Typ e Element lb L1 120 -80 .25 Pole TP25 .8 98xl 6 .25x0.1875 -5107 .41 L2 80.25 -29 .8333 Pole TP3 7.7 59x24 .7139x0 . I 875 2 -10001.70 L3 29.8333 -0 Pole TP44.625x36 . I 907x0.25 3 -144 31.20 Program Version 2.0.0.68 -11/19/2003 File:G:/TOWER/320_Newmark/32003-0l 48.eri SF*Pt1 110 .... lb 11 1171.80 34661 3 .31 836742.73 Po le (L2 ) RATlN G = % Cnpnciry 4 1.3 92.3 76.0 Summary 92.3 92 .3 Designed by rte al P ass Fail Pas s Pa ss Pass Pass Pa ss PJF Pole (tm) -Monopole Design Program Windows Version 3.04.00 00 Wed Nov 26, 2003 -11:24:41 am (c) 1993 to 2000 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No ...... : 32003-0148 Design No: Newmark no. 03-372Engineer : RWH Description 120-Ft Monopole -A3K021, Varsity Ford; College Station , Texas Design..... 90 mph Basic Wind Speed Owner...... T-Mobile Client: Newmark International, Inc. Status..... Final Design Revision: Rev . Date : M 0 N 0 P 0 L E Shaft Shape ..... : Base Dia, DF .... : PT-to-PT, DP .... : Min Bolt Circle .: Base Reactions Moment .............. : Axial Load .......... : Anchor Bolt Details Number of Bolts ...... Bolt Diameter ........ Bolt Type ............. Y-Di s tance ........... Mom. of Inertia . ..... Bolt Tension, T ....... Allowable Tension .... Bolt Compression, c .. Base Plate Details Plate Moment, MPL ... : Bend Plane, W ....... : Plate Thickness, t .. : Plate Width···~· .... : Plate Steel ......... : Gross Weight ........ : Net Weight .......... : Allowable Stress .... : Actual Stress ....... : Act./Allow Rati o .... : B A S E B A S E P L A T E D E S I G N D E T A I L S 18 Sided Polygon 44.62S Inches 4S.313 Inches Sl.62S Inches Stress Increase ... : 1.333 Factor Base Plate Shape .. : Round Use Bolt Circle ... : S1.SOO Inches DESIGN 129S.91 Ft-Kips lS.01 Kips DESIGN 8 2.2SO Inches #18J ASTM A61S 3 266S.14 In "'4 lS0.61 Kips 194.81 Kips 1S2.49 Kips DESIGN S33.72 In-Kips 17.70 Inches 1.902 Inches S6.87S Inches ASTM AS72 GRADE SO (SO KSI) 1370.30 Lbs 1047.SO Lbs 49.99 Ksi 49.99 Ksi 1. 00 USER 1 300.0 0 Ft-Kips 16.00 Kips USER 8 2.2SO Inches #18J ASTM A61S 3 26S2.2S In "'4 lSl. 46 Kips 194.81 Kips 1S3.46 Kips USER S27.Sl In-Kips 17.70 Inches 2.0 00 Inches S7.SOO Inches ASTM AS72 GRADE SO (SO KSI) 1472.80 Lbs 1133.30 Lbs 49.99 Ksi 44.69 Ksi 0.89 P L A T E D E S I G N S U M M A R Y USE FOLLOWING SPECIFICATIONS: Plate Thickness . . . . . . 2.000 Inches Plate Width /Diameter : S7.SOO Inches (Round) Plate Weight . . . .. . .. .. . . 1. 473 Kips Number of Bolts ... Bolt Circle ........ Bolt Diameter ...... Bolt Type .......... 8 Sl. SO Inches 2.2S Inches #18J ASTM A61S PJF Pole (tm) -Monopole Design Program Windows Version 3.04.0000 Fri Nov 21, 2003 -3:21:07 pm (c) 1993 to 2000 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No ...... : 32003-0148 Design No: Newmark no. 03-372Engineer : RWH Description 120-Ft Monopole -A3K021, Varsity Ford; College Station, Texas Design..... 90 mph Basic Wind Speed Owner...... T-Mobile Client: Newmark International, Inc. Status..... Final Design Revision: Rev. Date : SUMMARY 0 F C U R R E N T C A I S S 0 N D E S I G N Diameter (ft) ...... 6.00 Compression (kips): 16.00 Friction S.F . ...... 2.00 Min. Depth (ft) .... 16.00 Horizontal (kips) : 18.00 Lateral S.F . ....... 2.00 Depth Used (ft) .... 16.00 Uplift (kips) . .... 0 .00 Concrete S.F . ...... 1. 30 Rebar Area (in A2) . . 21. 84 Moment (Ft-kips) .. 1300.0 Concrete F'c (psi) : 3000.0 Rebar Used . . . . . . . . : (14) #11 Full Cohesion (ft): 18.00 Steel Cover Water at (ft) . . . . . .. 12.00 Rock at (ft) ...... 99.00 SOIL PROFILE Soil Layer Unit Ult. Skin Allowable Friction Passive Layer Thickness Weight Friction Bearing Angle- (ft) (pcf) (psf) (psf) (deg) 1 3.00 110.00 0.00 0.00 0.00 2 3.00 130.00 0.00 0.00 0.00 3 6.00 130.00 0.00 0.00 0.00 4 5.00 64.60 0.00 5000.00 28.00 5 5.00 64.60 0.00 6500.00 32.00 6 10.00 64.60 0.00 7000.00 LATERAL / MOMENT CAPACITY (CHECK) : Caisson Diameter (ft) ............................ . _ He_ight Above Grade (ft) .......................... . Depth Below Grade (ft) ........................... : Concrete Volume (CY) ............................. . Applied Moment From Loads (Working), Mwork(Ft-kip): Resisting.-Moment From Soil (Ult), Mult (Ft-kip) ... . Moment S . F . (Mu 1 t I Mwo r k) ....................... . Applied Horizontal Load (Working), Hwork (Kips) .. : Horizontal Soil Resistance (Ultimate), Hult (Kips): Horizontal S.F. (Hult I Hwork) ................... . Center of Rotation (from grade ) (ft) ............. : Inflection Point (Max Design Moment Location (ft) Maximum Fac..tote.9 . Design Moment for Rein£. (Ft-kip) : Area--s:te~~.f .R~quired From Loads (in A 2) ............ : ACI Minimum Steel (0.5 %) (inA2) .................. : Area Reinf. Steel Provided (in A2) ................ : UPLIFT CAPACITY CHECK : Actual Uplift on Caisson (Kips ) .................. : Allowable Uplift Capacity (Kips ) ................. : COMPRESSION CAPACITY CHECK : Actual Compression on Caisson (Kips) ............. : Total Compression (Includes Concrete Wt.) (Kips) .: Allowable Compression Capacity (Kips) ............ : CAISSON DESIGN: 0.00 Phi Coeff.- 1.000 1. 000 1. 000 2.770 3.255 1. 000 Min Design 6.00 0.50 16.00 17.28 1494.40 3033.02 2.03 18.00 42.30 2.35 10.30 3.80 1780.28 12.00 20.36 21. 84 0.00 50.34 16.00 40.74 141.37 USE: 6.00 ft Diameter X 16.50 ft Long (Concrete Volume = 17.28 CY) (in) ... 3.00 Cohesion KP (c) (psf) 0.00 2500.00 3000.00 0.00 0.00 2500.00 Actual Design 6.00 0.50 16.00 17.28 1494.40 3033.02 2.03 18.00 42.30 2.35 10.30 3.80 1780.28 12.00 20.36 21. 84 0.00 50.34 16.00 40 .74 141.37 Reinf: (14)#11 Vert, w/Closed Ties: (12)#5 @6.0", remaining ties @18.0" (ASTM A615) ((~ Date Submitted COLLEGE STATION ef D D DEVELOPMENT PERMIT MINIMUM SUBMITTAL REQUIREMENTS $200.00 development permit fee. Drainage and erosion control plan, with supporting Drainage Report two (2) copies each Notice of Intent (N.0.1.) if disturbed area is greater than 5 acres LEGAL DESCRIPTION-------------------------- APPLICANT (Primary Contact for the Project): Name Vo;ce filce~tt iLs% ;to:O l'o -~n Sf,J)~E-Mail s~~" .s+j ,."'l'\_ci) +--r'\ob; J-e -U> VY\ StreetAddress 2-Gre~w~ f\CL~ ,z #J /00 City Ho U:i-fo n State JX. Phone Number 7/ 3 -ljo 7 -? l/S:2 Fax Number OWNER'S INFORMATION: Name _.__.__,J~_iU _ _..,.,_-\,-1--'---"'-J_D_/Z----'-'7 ~-- Street Address () AJ Ii AJ r csJ E-Mail Zip Code { ( OY ~ 7/ 3 -<f D 7 -3 '-IO 3 City ~/:J ~0J 'state r& ZipCode /7V 3 Phone Number J l3--f' J--7---C) )...-£ 2..----" Fax Number 7;1 -'i? >-7 - / () 7 ;iL ARCHITECT OR ENGINEER'S INFORMATION: Name Mo8 E-n~~; f'--~L-L G StreetAddress CfOOb SW ~~ City Ho1A 5 ±o r'i state Phone Number 7/ 3-773 -252§ E-Mail -------------,:# '-ilO -(x Zip code { ( O_r-'-g-+. __ Fax Number 1 1 S ...,, 7 ? J --2 r; 5' 9 Application is hereby made for the following development specific site/waterway alterations : N(l,J MDno fo lt (120') l.\J,'~ ntw °'-.t\h,on r,('> ,4/\(1 j]=r\jl\A-~I\ lfJVVlMJJ..A;u-J, o ~'~Y~ ACKNOWLEDGMENTS: I, , design 'engineer/owner, hereby acknowledge or affirm that: ~ .=.c:a.'""".,_..-A .y. Metjul'5 The information and conclusions contained in the above plans and supporting documents comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design Standards. As a condition of approval of this permit application , I agree to construct the improvements proposed in this application according to these documents and the requirements of Chapter 13 of the College Station City Code 1 of 2