HomeMy WebLinkAboutResponse to staff comments p McCLURE & BROWNE, ENGINEERING /SURVEYING, INC.
• N & i• 1008 Woodcreek Dr., Suite 103 - College Station, Tx. 77845 - (979) 693 -3838 Engineer Reg. No. F -458
1314 10th Street, Suite 210 • Huntsville, Tx. 77320 - (936) 294 -9749 Survey Reg. No. 101033 -00
October 17, 2012
Morgan Hester
Staff Planner
Planning & Development Services
City of College Station
Post Office Box 9960
College Station, TX 77842
Re.: Pebble Creek Ph 7 -B2 L3OR & L31 R Blk 39 (FP — Minor Plat)
Staff Review Response
MBESI #: 1000 -0237
COCS #: 12- 00500199
Dear Morgan Hester:
Below is the summary of the revisions made per staff's comments:
PL NING (Reviewed by Morgan Hester Date: September 24, 2012):
MMENT #1: Please change the title to read that this is a Final Plat of Lots 30R & 31 R, Block 39
Being a Minor Replat of Lots30 and 31, Block 39 Pebble Creek Subdivision, Phase
7 -B2. /
ACT N #1: See revised Final Plat
MMENT #2: Please fill in or remove the ownership information in the title block.
C ON #2: See revised Final Plat
N r t
MENT #3: Please update the Notary Public Certificate associated with Davis M Young's
Certificate of Ownership and Dedication to remove the "(s)" and "is /are ".
CTION #3: See revised Final Plat
0 MENT #4: Please remove "A Certificate of Approval" as this is not an ETJ plat and is not
required to be provided on this document.
CTI N #4: See revised Final Plat
ENGINEERING COMMENTS (Reviewed by Carol Cotter Date: September 24, 2012):
COMMENT #1: Once conduit for electric line is adjusted per CoCS Electric Department
specifications, plat can be filed and service to street light can be reenergized.
ACTION #1: Duly Noted
ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION:
COMMENT #1: Coordinate with CSU for existing street Tight circuit to be de- energized prior to start of
work described below.
ACTION #1: Duly Noted
Pebble Creek Ph 7 -B2 Minor Plat Page 1 of 2
City Comment Response Letter
COMMENT #2: CSU will require that builder /developer intercept existing 1" street Tight conduit at
base of street light and extend new 1" pvc conduit to rear of property at a depth of
30" and intercept existing 1" conduit at that point.
ACTION #2: Duly Noted
COMMENT #3: CSU will require new street light wire to be provided by builder /developer. Wire size
required is #12 -CU, a total two runs from the base of the street Tight to the
transformer, one black wire and one white.
ACTION #3: Duly Noted
COMMENT #4: The new conduit can be installed within proposed easement boundaries prior to
easement dedication, however, CSU cannot re- energize the street Tight circuit in the
new location until the easement described below is in place and documentation is
received by the City of College Station.
ACTION #4: Duly Noted
EASEMENTS:
COMMENT #1: Existing 5' PUE between Lot 31 and 30 to be adjusted /relocated.
ACTION #1: See revised Final Plat
COMMENT #2: The existing 5' PUE to be adjusted /relocated as follows:
• 5' PUE along length of property line between Lot 31R and 30R on the 31R side
of the property line.
ACTION #2: See revised Final Plat
GENERAL ELECTRICAL COMMENTS (Reviewed by Gilbert Martinez Date: September 24, 2012):
COMMENT #1: Developer installs conduit per CSU specs.
ACTION #1: Duly Noted
COMMENT #2: Developer will intercept existing conduit at designated streetlight and back property
line and extend as required.
ACTION #2: Duly Noted
COMMENT #3: To discuss any of the above electrical comments please contact Gilbert Martinez at
979.764.6255
ACTION #3: Duly Noted
If you have any questions or additional comments, please do not hesitate to let me know.
Sincerely,
Kevin McClure
Pebble Creek Ph 7 -B2 Minor Plat Page 2 of 2
City Comment Response Letter
Carol Cotter
From: Gilbert Martinez
Sent: Tuesday, October 09, 2012 2:02 PM
To: Carol Cotter
Subject: 1405 Mission Hills
Hi Carol,
I just got a call from the electrical supervisors letting me know that the street light circuit at 1405 Mission Hills has been
relocated to the new property line. A crew is on the way to re- energize that street light as I type this. That takes care of
any issues that electric has with the relocation of that property line. Let me know if you need anything else.
Regards,
Gilbert Martinez
EPC Supervisor
Phone: 979.764.6255
Fax: 979.764.3452
1