PREPARED 3/18/08, 8:00:07 INSPECTION TICKET PAGE 14
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/17/08
------------------------------------------------------------------------------------------------
ADDRESS DR SUBDIV: SPRING MEADOWS PH 2
CONTRACTOR GOLDEN HOMES PHONE (979) 694-3600
OWNER WOODLAND HILLS DEVELOPMENT LTD PHONE
PARCEL 582830-0201-0020
APPL NUMBER: 07-00003439 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/20/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
12/20/07 AP December 19, 2007 3:44:56 PM glsouth.
THURSDAY AFTERNOON
December 20, 2007 4:34:32 PM kwolfe.
B115 01 1/15/08 RH BLDG, FRAMING TIME: 17:00
1/15/08 AE January 15, 2008 9:32:23 AM acarter.
O1/15/2008 04:25 PM RH PDA
Need joist hangers in master. Repair loose TYVEK. By
insulation.
B130 01 1/17/08 BH BLDG, INSULATION TIME: 17:00
1/17/08 AP January 17, 2008 8:29:39 AM kwolfe.
January 17, 2008 8:29:56 AM kwolfe.
B125 01 3/17/08 B BLDG, FINAL TIME: 17:00
-1 S,6& 14
March 17, 2008 4:10:41 PM acarter.
----------------------- ------------ CONTINUED ONTO NEXT PAGE ---
Date: 3/18/2008
Inspection Comments for Final,
Permit Year: 7 permit Number: 343�
Address: 4400 SPRING MEADOWS DR
TYPe
Inspection Type Code
siat�s
Inspection Result Comments
Description
B100
BLDG, FOUNDATION-SL,
IC
December 20, 2007 4:34:32 PM kwolfe.
B115
BLDG, FRAMING
IC
01/15/2008 04:25 PM RH PDA
B115
BLDG, FRAMING
IC
Need joist hangers in master. Repair loose TYVEK. By
B115
BLDG, FRAMING
IC
insulation.
B130
BLDG, INSULATION
IC
January 17, 2008 8:29:56 AM kwolfe.
P105
PLBG, TOP OUT
IC
01/10/2008 10:49 AM RH PDA
P105
PLBG, TOP OUT
IC
Protect pipes passing through w/h cabinet.
PREPARED 3/18/08, 8:00:07 INSPECTION TICKET PAGE 15
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/17/08
------------------------------------------------------------------------------------------------
ADDRESS . : 4400 SPRING MEADOWS DR SUBDIV: SPRING MEADOWS PH 2
CONTRACTOR GOLDEN HOMES PHONE (979) 694-3600
OWNER WOODLAND HILLS DEVELOPMENT LTD PHONE
PARCEL 582830-0201-0020
APPL NUMBER: 07-00003439 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: MECH 00 MECHANICAL PERMIT SUB: LAVCO A/C (979)776-2756
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
M100 01 1/15/08 RH MECH, ROUGH IN TIME: 17:00
1/15/08 AP January 15, 2008 9:49:26 AM acarter.
M110 01 3/17/08 BI MECH, FINAL TIME: 17:00
March 17, 2008 4:19:03 PM kwolfe.
-------------------------------------- COMMENTS AND NOTES--------
WF0985210 / 001 City of Co11iE�ge�,Station
PAGE 1
REQ. DATE: 12/03/07 12/03/07 11:56:22
LOCATION: 4400 SPRING MEADOWS DR LOC ID: 199554
REQUESTOR: GOLDEN HOMES I ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 12/03/07 SCHED COMPLETION: 12/03/07
********************************************************************************
JOB ORDER RESULT COMMENTS
Mar 19 08 11:00a MACIAS 9797744736 p.2
3q 3q
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
GOLDEN HOMES, INC.
4400-SPRING MEADOWS
2856.
Percentam of _ 111 t. • _ to • a applied at this• y. r♦ Foundation: SLA13- Sidina's BRICK
Type of Imatment: Full Partial XX Vertical XX
HorizontaUPerimeter
UIC1.•1ii >• r • is ! ! 1 • c� 1 1.- 1 • • :! •.. i! ! • JI 1
A LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF AN1ry
INCLUDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE-
TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITNIN THE WARRANTY PERIOD, AND THE CONWWNS THAT
COULD DEVELOPAS A RESULT OF THE OWNERS ACTION OR INACTION THAT WOULD VO[D THE WARRANTYHAS ALSO BEEN ATTACHED.
Charges for pre -treat:
NOTES: Annual re-newal:
SEE: ATTACHED SKETCH
#UUMERS-SUPPL9.9S SKETCW.PLAN
$399.84
$130.00
32129 PT 12118/2007
Ca or Tockinchm SPCB resn¢e ft 32129 PT
w,-__,.__--_,-_-_� _ .__.__.w___-_- �,—�,�,.,w�� "- ---u ---_ �_-.-, ..._ ,_,_w—_ v____w _T._._ —. _ _.______.__.
;Amber Carter - Re CAlling for CO for 4400 Spring,Meadows Dr� Page 111
From: Mitchell Carson
To: Amber Carter; Benjamin McCarty; Chris Haver;
Date: 3/18/2008 12:01 pm
Subject: Re: CAlling for CO for 4400 Spring Meadows Dr
This one is OK Mitch
>>> Amber Carter 03/18/08 8:29 AM >>>
by 07-3439
Any issues?
. (3/18/2008) Gina Southerland Re: CAlling for CO for 4400 Spring Meadows Dr _m Page 1 i
From: Mitchell Carson
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 3/18/2008 12:01 PM
Subject: Re: CAlling for CO for 4400 Spring Meadows Dr
This one is OK Mitch
>>> Amber Carter 03/18/08 8:29 AM >>>
by 07-3439
Any issues?
4400 Spring Meadows.
Spring Meadows Phase 11
(1/17/2008) Kim Wolfe - Insulation request inspection result, 4400 Spring Meadows, #07-3439 Page 1
From: Brian Henry
To: Southerland, Gina
Date: 1/17/2008 8:28 AM
Subject: Insulation request inspection result, 4400 Spring Meadows, #07-3439
CC: Carter, Amber; Wolfe, Kim
Print for File
Inspected insulation, 4400 Spring Meadows, #07-3439, Golden Homes, 1-16-08
Inspection result: Inspected OK for Good Cents
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE' STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-349.6-
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number
. . . . . 07-00003439
Date 12/03/07
Application pin number . . . 991958
Property Address .
. . . . . 4400 SPRING MEADOWS DR
Property ID:
582830-0201-0020
R #:
R116791
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name
. . . . SPRING MEADOWS PH 2
Property Use . . .
. . . . . RESIDENTIAL
Property Zoning . .
. . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 140250
Owner
Contractor
------------------------ ------------------------
WOODLAND HILLS DEVELOPMENT LTD GOLDEN HOMES
1700 BARAK LN
2912 CAIN RD
BRYAN
TX 778023311 COLLEGE STATION
TX 77845
(979) 694-3600
--- Structure Information 000 000 SINGLE FAMILY
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2125.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TRAFFIC IMPACT ANAL (TAZ)
441.00
-----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit pin number .
538322
Permit Fee . . . .
583.00 Plan Check Fee
.00
Issue Date
12/03/07 Valuation . .
. . 140250
Expiration Date
5/31/08
Qty Unit Charge Per Extension
BASE FEE 460.00
41.00 3.0000 THOU BLDG, VAL 100001-500000 123.00
-----------------------------------------------------------------------------
Special Notes and Comments
-Narrow Wall Bracing Fully Sheathed with APA Garage Framing
-Make sure windows meet egress requirements.
-------------------------------------------------- --• ------------
BUILDING DEPT REPRE gNTAT VE:
APPLICANT: IAZ /
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE -STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 07-00003439 Date 12/03/07
Application pin number . . . 991958
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 30") WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
------------------------------------------- ----- -- -- ------------
BUILDING DEPT REPRES TAT VE:
// .
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE'STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number 07-00003439 Date 12/03/07
Application pin number . . . 991958
----------------------------------------------------------------------------
Special Notes and Comments
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam.or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANC FROM FORCED AIR
---�-- -
BUILDING DEPT REPRES/ TAT VE:
APPLICANT: . /
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE -STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 07-00003439 Date 12/03/07
Application pin number . . . 991958
----------------------------------------------------------------------------
Special Notes and Comments
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20o A .40 OR LOWER FACTOR AND ABOVE 200
TO 30o A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
-----------------------------------------------11----------------------------
Other Fees . . . . . . . SEWER TAP 4 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- --- ------ ---------- ---------- ----------
Permit Fee Total 583.00 583.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 750.00 750.00 .00 .00
Grand Total 1333.00 1333 00 .00_ .00
------------------------------------------- --- /�- 04*4�------------
BUILDING DEPT REPRE,5�ENTAT�IVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE -STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00003439
Application pin number . . . 991958
Page 5
Date 12/03/07
----------------------------------- - - - - -------�- ---------------------
BUILDING DEPT REP5ESEI/WATIV�
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
07-00003440 Date
12/03/07
Application pin number
123680
Property Address . . . . . .
4400 SPRING MEADOWS DR
Property ID:
582830-0201-0020
R. #:
R116791
Application type description
TEMP POLE
Subdivision Name . . . . . .
SPRING MEADOWS PH 2
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
WOODLAND HILLS DEVELOPMENT LTD
------------------------
GOLDEN HOMES
1700 BARAK LN
2912 CAIN RD
BRYAN TX 778023311
COLLEGE STATION
TX 77845
(979) 694-3600
-------------------------------------
Permit . . . . . . TEMP POLE
---------------------------------------
PERMIT
Additional desc . . GS
Permit pin number . 538330
Permit Fee . . . . 20.00
Issue Date . . . . 12/03/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
---------------------------
Paid Credited
------------------------------
Due
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
-
�1'i�lrrM1►�Y1�
1
CITY OF COLLEGE S"PATIO\
Pb,,.i,g b Daxlopmmr Se im
ADDRESS/LOCATION: `/yo o S rl 1 "1e LV &rf
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
V/1",
IFor Office Use Only
DATEa e e TRCCI
APPLICATION #
TEMP POLE #
LOT .2*400" BLOCK SUBDIVISION Sbri ..� wex AW-f ✓ SEC/PH
BUSINESS/OWNER NAME: / "(Ar /( e�rb GAS In re� PHONE: SAS + /7 elf
CONTRACTOR/HOMEOWNER: IJToUe L) PHONE:
CONTACT PERSON FOR REVIEW COMMENTS:
PHONE:
FAx: 6' /yy/ EMAIL: /
ELECTRICIAN: t'f [ [ / e d PLUMBER:
HVAC: tel. to GOOD CENTS (Residential only): y�S
ACCESSORY/STORAGE MOVING RE -ROOF
ADDITION NEW CONSTRUCTION" SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEL/RENOVATION" TENTS
( DESCRIPTION OF WORK: /
PROPOSED USE:
u�STRUCTURE USE:
Vvv V(�• HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
�.! TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ *-Z3/'7
VALUATION: $ ,JSVOK , Zst% f TOTAL AREA: .27,4/ HEATED AREA:
oO (Cost of tabor and Materials) L,
a� dPUBUC SEWER NUMBER OF BEDROOMS: T
7v\
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: �.
[SEWER TAP: 1V INTERIOR WALL TYPE:
Sum
• WATER TAP: 3 y EXTERIOR WALL TYPE: /"(u So•V!-
SUE
Sf.
00
OTHER TAP: FOUNDATION TYPE: Spa l
/ SUE�J
0 TEMP POLE ROOF TYPE: (,,0 All,r
�r 1 GARAGE TYPE: SINGLE DOUBLE TRIPLE
ATTACHED EfDET HED CARPORT ED
SIGNATURE OF APPLICANT:
If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
............................................................
Official Use Only
7/5 %f _&,07
Gj� Plans Examiner
17
Iolls,t.0
Qmpa
` 7 _T144_-vm 14ccas
��3r� wr r-WI' ,w s-f ,fit ;5 jA-esf
Comments:
YES or NO
Zoning fi`icial
"1
Erie gy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
.13
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
T - I l
Glazing SHGC (Solar Heat Gain Coefficient)
ow E ,
Glazing U-Factor
R value of ductwork
- G
A/C SEER Rating
< y su r +/
,
t
Protection Against Subterranean Termites
Chemical Termiticide Treatment (Soil Treatment)
/�� �� Lo' N �r•
S�
O Chemical Termiticide Treatment (Field Applied Wood Treatment)
O Physical Barriers
O Other
* Verification of Application shall be submitted to the City of College Station -
Buildirig Division prior to issuance of the Certificate of Occupancy.
is
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning dDevelopment Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 0 -*7 -3V39
DATE: // _ / S _ 0 ./
BUILDING ADDRESS:
I. Foundation Requirements- Minimum City Found ion Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
OK
ll. Framing: Floor, Wall, Ceiling and Roof Requirements
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
San exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
K
K
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning dDevelopment Service; COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
A'qV
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
CITY OF COLLEGE STATION
Planning d Development Service;
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NAffij
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NWiq
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLA S EXAMINER
Il� e-Z-0-7
DATE