HomeMy WebLinkAboutRES2007-03401�•�oi PREPARED 12/08/08, 12:03:20 INSPECTION TICKET PAGE 4 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/08/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 2461 NEWARK CIR SUBDIV: CONTRACTOR CLASSIC CENTURY HOMES PHONE (817) 561-4369 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-2501-0190 APPL NUMBER: 07-00003401 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 O1 1/08/08 RH BLDG, FOUNDATION -SLAB TIME: 17:00 1/08/08 AP January 7, 2008 2:49:13 PM acarter. tuesday afternoon please O1/08/2008 04:42 PM RH PDA Strings up, slab ground installed. B120 01 2/01/08 OC BLDG, FRAMING -PARTIAL TIME: 17:00 2/01/08 AP February 1, 2008 9:06:18 AM kwolfe. APA FRAMING B115 -Dl 3/11/08 RH BLDG, FRAMING TIME: 17:00 3/11/08 DP March 11, 2008 11:30:51 AM acarter. Windows upstairs must be 24" min above finish floor. V Draftstop a/c chases. Fireblock fireplace every 101. Stairs exceed 7 7/8" in riser height. Tape all seams and holes on green guard. Block between floor joist. B115 02 4/09/08 RH BLDG, FRAMING TIME: 17:00 4/10/08 AE April 9, 2008 11:32:34 AM npadilla. Connect loose wires in utility room by insulation. B130 01 4/11/08 RH BLDG, INSULATION TIME: 17:00 4/14/08 DP April 11, 2008 11:35:33 AM malford. April 14, 2008 8:48:25 AM bcaldwell. insulate area between floors above master bath and garage. seal all exterior wall corners. B130 02 4/15/08 BB BLDG, INSULATION TIME: 17:00 5/08 AP April 15, 2008 8:12:57 AM acarter. B125 01 131 BLDG, FINAL TIME: 17:00 December 8, 2008 10:53:25 AM ccourt. -------------------------------------- COMMENTS AND NOTES-----------J ---------------------- �g iu! I. Terry Boriskie C/O Issues 1 From: Terry Boriskie To: fredburris Date: 12/29/2008_12.56_p.m­-D Subject: C/O Issues Fred, I am trying to clear up items that have been sitting out there for a while and are simple to get done in order to issue a C/O. The following addresses need Proof of Termite Forms: 108 Roucourt 2447 Newark 2461 Newark 3901 Tournay 3903 Tournay 200 Passendale *2447 Newark also has a Handrail issue on the back patio steps to be resolved. Thanks, Terry Boriskie City of College Station Residential Plans Examiner Ofc. 979-764-3744 Fax 979-764-3496 "Home of Texas A&M University" TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT Proper Owner: CLASSIC CENTURY HOMES AD I Location to be Treated: 2461 NEWARK v Approximate Measures to be Treated: 3304 Percentage of Termticide(s) to be applied at this location: 0.06% 110 GAL. Type of Treatment: Full Partial XX Vertical XX HorizontallPerimeter Beam—XX— Foundation: SLAB Siding: BRICK Primary Use: RESIDENCE Roof: COMPOSITION A label of Talstar One insecticide has been attached as part of this document A LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY) LNCLUDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE- TREAT FOR TERMITE INFESTATIONS OR REPAIR OAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED. SEE ATTACHED SKETCH BUILDERS SUPPLIES SKETCH/ PLAN Charges for pre -treat: NOTES: Annual re-newal: $357.66 $130.00 32129 PT 12/29/2007 Ca or Techindan SPC8 Goenae IY 32129 PT £'d £Z8£ 069 6L6 So/8 - 400 189£:1 l 60 Z L Uef WF0989229 / 001 City of College Station PAGE l REQ. DATE: 12/17/07 12/17/07 13:42:06 LOCATION: 2461 NEWARK CIR LOC ID: 204002 REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/4" TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/17/07 SCHED COMPLETION: 12/17/07 JOB ORDER RESULT COMMENTS 2461 NEWARK CIRCLE LOT 19, BLOCK 1 CASTLE GATE COLLEGE STATION, BRAZOS CO.. TX FtATWORK 1050 SQ/FT GRASS 220 YDS 51' 0" 13' 0" 16' 3" 16' 1" L 5' 8" 3'0'x BO' 3'Px60' 3'0'x E0' 3'Q'x B0' 3'0'x S0' 3'0'xS 0' Tr II----------- NISTR SUITE CD 1 8'0" SLOPE TO 10'0" BREAKFAST II 11 _ -------------- ------------------------------ � (�Vjll �L 11. c 6 � I I 2' 10 9'0" CLG FAMILY -N N rrI I F 9'0' CLG 70 i 3' 0" 3' 8 3' 5" 3' 2" „ _ o c KITCHEN ® 4 M 10' 8" W; 70 7 I I _ b ®® 2' ' 8' 11 " 3' 8" 1 3' 8" 0 zv `O d `�' Y OVEN c'7 II Q . ze' zir 78' IIco ARCH UP 15R D b c / / ENTRY B II w o :- DINING ;; re 9'0' CLG 6' 8" 3' 5" o 10'1" 111'8" JS o ih `a<I FOOTAGE o LOWER AC 1571 iv N UPPER AC 1060 /18 aPl q 4, 7" 2' 0" 2.6" 910. 13' 7" N 22' 7" 28' 8" TOTAL A/C 2631 GARAGE GARAGE 635 8'0" CLG PORCH 38 CD 6' 1 TOTAL 3304 0m N 51' 0" PLAN # 2431 lassic Century Homes ,DRESS 2461 NEWARK CR LOT 19 BLK 1 SUBDIVISION CASTLE GATE ff ft'v— 22' 4" L \� SEE ELEVATIONS FOR WINDOWS SIZE AND LOCATION NOTE: 1) SHADED WALLS TO 211 x ro" FOR PLUMBING 2) ALL HEADER WEIGHTS TO BE 6'10" UNLESS OTHERWISE NOTED 3) PROVIDE TEMPERED GLASS WHERE NEEDED 43' 10" 10' 9" 2' 4° 16' 3" 14' 6" ---------------------------- ----------------------------------------------------- -- 0 0 F70•x S0' 3'0'x50' 3'(•xSD' 3'Rx50' I I 71 / to - - - - - - - - - - - i b ' BDRM 2 8'0" CLG GAMEROOM I AC 8'0° CLG rh 9' 5° 3' 8" `D 16' 3" I I I in re 4' 8° 2' 0° 4' 6' ' 4" }� in r N in I b ,� N = 11 o m ^ fo a I I - cn 42" TALL WALL DN 15R I C" ----------- - - - A (V a ( Ye ENTRY I b N cm D 18'6" CLG 10. T 4" 3' 8" BDRM 3 8'0' CLG PLANT SH 4' 5" 4' 3 1/4" 5' 6 3/4' o, 10'0" v 0 fV O fV 2' 6" 12' 0" 1 4' T' 12' 0° 1 2' 6- 15' 11" 14' 3" PLAN # 2431 Cassic ADDRESS 2461 NEWARK CR LOT 1 Q Century BLK 1 J Homes SUBDIVISION CASTLE GATE N.Uwn-°-..* ngineering, LLC October 24, 2007 Classic Century Homes 5001 Hwy. 287 South Arlington, TX 76017 401 S. CLAY STREET, ENNIS, TX 75119 The following post -tensioned foundation plans are herein authorized for construction at the address and legal description shown below. Lot Blk Subdivision Address CSC County State 19 1 Castle Gate 2461 Newark Circle . College Station Brazos TX A site specific soils report was not provided. The foundation has been designed based on the following soils conditions. Soils Laboratory Brazos County USDA Soils Survey Allowable Bearinq Pressure P.I. 1200 psf 36 The foundation design is in accordance with the applicable provisions of the International Building Code 2000/2003 Edition, the International Residential Code 2000/2003 Edition, the Design and Construction of Post - Tensioned Slabs -on -Ground, Second Edition, 1996 by the Post -Tensioned Institute, applicable provisions of the Building Research Advisory Board (BRAB) Publication 33, and accepted engineering practice. If you have any questions, please call me at 972-878-3647. _ PTF1007035 1012412007 A.G. (Tony) Medina Registered Professional Engineer PHONE: 972.878.ENGR (3647) - FAX: 972.875.1398 - E-MAIL: info@txfoundations.com PROVIDE STEEL LINTELS AT ALL MASONARY OPENINGS AS REQUIRED BRICK QUOINS lc). A 1 u1 w 1' PROJECTION 3' x T OL 111 W1 Y x 1'6' AR TR W1 Y x T6' AR TR ROWLOCK T' x 4' DL MULLED 2 - 1'6' x 6 DL ill TO SURROUND WINDOWS (2) 2'X 6'DL 1/1 WITx3'6'ARTR 3'x6OLIII PLAN It 2431 Csic ADDRESS 2461 NEWARK CR LOT 1 g Century BLK 1 Homes SUBDIVISION CASTLE GATE NOTE: 1) SHADED WALLS TO 2"x 6" FOR PLUMBING 2) ALL HEADER HEIGHTS TO BE 6-10" UNLESS OTHERWISE NOTED 3) PROVIDE TEMPERED GLASS WHERE NEEDED ri. 11" 13'0" 16'3" 16* 1 5.8- rr 70'. 5'W 11 NISTR SUITE ........... 8W SLOPE TO 10'0- BREAKFAST 11 ---------- .. .................... QI io 2' 10 9'0'CLG ry FAMILY 97CLG TO" 3'8t 3'5" 3'2' zc b KITCHEN CHEN W: Ix. TO C 10, 8" 4HEN b < 2' zt 8' 1 L 3'8" 3'8" L) OVEN Q r Zr L < .--=... ARCH 11 no' ENTRY b s D B DINING 9'0" CLG rc 6,8 3-5- Ml L— FOOTAGE n)H LOWER AC 1571 UPPER AC 1060 TOTAL A/C 2631 GARAGE GARAGE 635 8'0"CLG PORCH 38 2' 61' 2]'0' _4' 71. 0" 2' 6" 9.0. 6'1 TOTAL 3304 13'7" 15' 1" —1 22'7" 6' O O ....... .... . . . . . . . 28'8" 22-4" 51 10. PLAN 0 12431 ADDRESS 2461 NEWARK CR LOT 19 BLK 111 7DIVISION I I CASTLE GATE 62- i �um -- Century Homes co SEE ELEVATIONS FOR WINDOWS SIZE AND LOCATION NOTE: 1) SHADED WAIII 5 TO 2" x 6" FOR PLUMBING 2) ALL HEADER HEIGHTS TO BE 6'10" UNLESS OTHERWISE NOTED 3) pgovIpE TEMPERED GLASS WHERE NEEPED 43' 10' 10' 9' 2' 4' L 16' 3' 14' 6' ------------------------------ O ----------------------------------------------- O FE -; I: 3'0'a50' JO•a60' 3'0•i50- r0•,sv V - - - - - - - - - - - - - y l tD BDRM 2 l 8'0- CLG GAMEROOM 1 AC 8'0" CLG I l 9,51 3' 8' m 16' 3' l 1 I 4"8• TO 4-6 13'4' in ze 1 b N = 11 l cr a' 42' TALL WALL DN 15R i N ------------------ A i 70 ENTRY N N 18'6" CLG 7' 4' JW 3 8' I l•- — — BDRM 3 8'0' CLG PLANT 5H 4'±5'4'3 114' S' 6 3I4' @ 10'0" 2' 6' 2' T 4' 7' 2' 0' 2' 6- 15' 11' 14' 3' 13' 7' 43' 9' PLAN # 2431 Ll4tiC ADDRESS 2461 NEWARK CR \/ LOT 19 Century B« 1 Homes SUBDIVISION CASTLE GATE 6 RIGHT ELEV my MIN. 0 ------------ z O ROOF AS SELECTED 55 @ 8:12 NOTE: 1) Foundation anchor bolts at 3) All lower sole plate to be 4) Provide hand rails on all stairs/steps 6'0" ox. as per 2003 IRC Pressure treated as per with a minimum of 4 risers as per sec. R403 1.6 sec. R319 All fasteners sec. R315. (min. stair tread 10": 2) All framing and structural to be hot dipped galv. steel, max. riser 7 3/4" sec. R3I4.2) design to meet 90 m p.h. stainless steel, silicon bronze 5) Masonary veneer anchorage of wind criteria as per sec. or coper only as per sec R602 24" horizontal and 18" vertical as R301.2-1 and table R301.2(4) per sec. R703 7.4.1 and weep holes 2003 IRC code. at a maximum of 33" o.c. as per sec. R703 7.6. 8' 1 1/8" PLATE 9' 1 1/8" PLATE PITCH @ 6:12 0 ; P1TC 1 @ 8:12/ 18' 8 1/8" PLATE J a- w co J m a co Go B0 18' 8 1/8" PLATE 9' 1 1/8" PLATE SIDING 8 ROOF DETAIL SIDING TO BE ALL TEMPLE BRAND 3RIC�1 _ HARD BOARD LEFT El REAR ELEV REVERSE DORMER, I .......................................................................................... DR GAMEROOM CLG 8V* CLG eLoc<n WIRE ONLY O ENTRY Qt8'6' CLG BDRM 3 PLANT SH 810' CLG C IO'0' ARCH WINDOW NOTE: 1) Lighting on stair to conect from switch @ lop to light mounted on wall @ middle of stairs to switch @ bottom of stairs per sec R303.4 2) Smoke detectors will be hard wired In series wl battery backup power as per sec. R317 3) Provide 110 outlet & light near HVAC unit for service with switch. MOTHER IN LAW SUITE PLAN 2431 ELECTRICAL PLAN AIMMSS LOT Century IILI: -T - es SUBDIVISION ElvcWul main tan clnwpw t (. n—swirnmo 0 PoI NIN v v v v v vvNly bar 1;941 G 1. vujct ® oWa122N 6Y 0,4008 —%.6tda s 6w1iNr gr S*tch 3 way 9' 1 9' 1 1/8" PLATE 8' 1 1/8" PLATE GABLE DOMER w Q J 00 T- Ia5 � Centu Homes 2431 TRUSSES PLAN PLAN Y ADDRESS LOT BL.K SUBDIVISION .VJ6t Ilrr O. w.aV �p..Id4 3) ALL LOAD BEARING WALLS TO BE FRAMED 16' 0 C. 4) ALL NON LOAD BEARING WALLS TO BE 24" 0 C 5) SHADED WALLS TO BE 2' x 6' THICKNESS FOR PLUMBING PLANK 2431 FRAMING PLAN Cics¢ ADDRESS LOT Century / y BILK Homes SUBDIVISION vurn ..o.�w•p rw 1 rvnancr: NI n Wr a nr in+n q n'.b nlKKllwa nrrw Ar Iaa Slnnr.n anam NK.utbr+ nc»namnAwnrmTn I I.—mao meconru .Toertvnva rm•.+.anunmon laranTunAtl e.an t+numssnaru nua eL\ooa nrancuto+a +v .;•Itt.1l.lila rIM uln"aa tlnaLaadelaS • 9MI L\+1 ,Tn.1nTI Ni 0.Vlnl tirlM1p141Y•<. eteilVlUL+lnl+q tSO, I+IILLI•AAI Mem nivAnn ITslnnntT PIVn\TnlaY llnmia \I rmrovr VIIAIBL•R Ia! r Ao v.an. 1. smAucw lsauun uleAnnanAna ITunmac mat yrntaa\ .uamwluntavm • '� •a a � nu annual Nanlra vrtA. J aaa It enrlanaum www ocvum L+G+IIt • (h T7p!C66 ROOF • 9NINGLES .ban �. Ira' PLYWOOD 8N—eATNING eao 'H' CLIPS MN. 2•N6' RAFTERS • 24' — BATT tN;Af .ATtON CONTIMOUB AIR VENT BAFFLES •74, O.C. ROOF PI END AT RIDGE TO BE INSTALLED SO THAT MR FLOW IS NOT r i IO—V�T.{AyN v RESTRICTED WOOD FASCIA SOFFR MATERIAL TYPICAL BRICK EXTERIOR WALL FACE BRICK INV I' AIRSPACE V2' SHEATHMG 61MOS • 16, o.a BATT INSULATION CITY OF LOCKHART UD• SWEETROCK TYPICAL ROOF OVERHANG DETAIL TYPICAL STALL DETAILS a ram vcww rmTtam�Aa\LrI avma. /rar. i NOTE loosxrraa.romnnAuautolnu vuurvvwr•uurlm I I Fmmdatmn anchor 6olU o \nv m aAmu+xur '0'f Go.c. a per 2EOO IRC sec. R-001.1.6 '-1.1t1(Moog and swctu al LT r11+11NONMTincO dtgn to oral 90 m.p.h. "not Rind [11[ma as ps see. R301 2.1 and mble R301.20) 2003 IRC code. 3)All to-rsalc plstc to he m a.Nut»:1oM_%MK pressatle tmted as per +rnnsien-e T. R323. All futmen to be IW, dipped C.Iv. sleol, raw+ ::a+tlk MtL nairdat steel, silicon blame \rrAl '1 •i or toper only Y, ptr sm. R323.3 r141 b•Ai 4) pro,ide hand ralli- allataitsimcps Sella•/IwnlT11Ar1annlS 4(0[ 'r`ta; °U1i ^'' �'. Q.V7 nith a minmara of 2 ricrs m pn .r vlwmw sec 11315.(min.avlrvnJ lO': nut. trier 7314'sm. 11314?I .•ol�inmalr.. nleArtl+snuw+ 51 b1awaw Tcnccr arKhoragT of Irvarnun 24'hon,-Ul and lS —t-Ias mop;sum Senn. Lw\In t\1K.LL1•n[Ka ..Nl �' YAtl.nl r+ler per sm. RT03.7.q.l andxTep halo crotrASs111aU t: vnn.e.ac uu a lanuxmWmaf33'o.e.asper mmlexnn urnly 1h,IIMtlfia0 sm R703.7.6, warwcsln45 uanll+n. $� nman nuL\m+ 18" Il_OOR SYSTEM Tanrnxc 4ai Mrnnr\\ N g a ammlw nnntuu O 111N.TRFAD ,LI (3)2x12 STRINGERS r, '`a�Il •'�',;;`� �di{.vyf%_ jmnNmew+T.Iotu.ner AZa,�0 U Y 51&' TYPE DRYWALL UNDER STAIR STRINGERS "-38" MAX.HANDlA1L Q34 FIRST FLOOR V=U TOP VIEW sir; STAIR DETAIL IRC 2003 CHIMNEY CAP \ 'LUE 2 101 III MIN. � CHIMNEY 2X4 BAND _ I , _ CAP ' 2X4 BAND 2X4 FRAM MEMBER - - - - - - —" _ 25 411 2X4 FRAMING--� _ _ _ _ - - MEMBER W� A" SIDE VIEW OSB I I1T55(` SIDING ---�� PT. ; Century I, 1 I r omes 1 , (� I 1 QO M1loklnp!!em(On•nmhFpAprdaFle /Q Area Calculator: Add to Library Window Name Assembly Type Quantity Width x Height = Unit Area Total Area U-Factor SHGC Comments/ Description 1 1 137 x 5'0" Metal Frame, Do 3 T-0" 6'-0" 18.00 54.00 ft2 1 0.6501 0.340 2 1 2 - 37 x 6'0" mulled Metal Frame, Do 2 6'-0" 6'-0" 36.00 72.00 ft2 3 1 13'0" x TO" Metal Frame, Do 1 31-0" 3'-0" 9.00 9.00 ft2 4 1 147 x 4'0" fixed Metal Frame, Do 1 4'-0" 4'-0" 1 16.00 16.00 ft2 5 1 3 - 3'0" x 5'0" mulled Metal Frame, Do 1 9'-0" I 5'-0" 1 45.00 45.00 112 6 TO" x 7'0" Metal Frame, Do 2 3'-0" 7'-0- 21.00 42.00 112 7 27 x 7'0" Metal Frame, Do 2 2'-0" 7'4' 14.00 28.00 ft2 8 3'0" x 6'0" Metal Frame, Do 2 T-0" 6'•0" 18.00 36.00 ft2 9 2'0" x 6'0" Metal Frame, Do 2 1 2'.0" 6'-0" 12.00 24.00 ft2 0.650 0.340 10 310" x 1'6" AR TR Metal Frame, Do 1 D = 3'-0" 3.53 3.53 ft2 0.650 0.340 11 1'4" x 60" sl Metal Frame, Do 2 1'-4" 6'-0- 8.00 16.00 112 12 TO" x 4'0" Metal Frame, Do 1 6'-0" 2'-0" 12.00 12.00 ft2 131 ITO" x TV AR TR Metal Frame, Do 1 D = 7'-0" 19.24 19.24 ft2 0.650 0.340 14 15 16 17 18 19 20 21 22 23 24 Window Area Total: 376.77 10/241071019:12 1/1 v> Area Calculator: �=MIIM! lawn== Description Door Area Total: 55.56 10/24/07 10:20:10 1/1 V j SIMPSON LSTA21 OR FRONT VIEW CS20 (ATTACH TO FRAMING ON OPPOSITE SIDES OF SHEATHING) TYPICAL BOTH SIDES 3" GRID PATTERN Sd '16" MIN.' OF OPENING. COMMON NAILS TO HEADER ° TOP PLATE TO HEADER - 2 ROWS OF a' HEADER CLEAR 16d SINKERS; 3"O.C.: SPAN ACROSS 3" O.C. NAILING IN ALL FRAMING -STUDS; .. BLOCKS, TOP PLATE, ° AND BEHIND THE STHD10 HOLDDOWN 3 BOTTOM PLATE TYPICAL 5/8" ANCHOR BOLT a. ° a°:.• 'e; : o .: a :. .. a: EMBEDDED 7" MIN. TYPICAL 2- SIMPSON HTT16 EACH SIDE - TYPICAL , 71 TOOv I N • �r r------------------------- I Sg Z 1 '-0° MIN. �---------------- LU Tt 2 1 x 4 LET -IN INTO TOP AND _ �� - TYR W � y BOTTOM PLATE AND g Vo INTERVENINGBTUD9.IYP:� 3� w a - > 12 $" > 25'-0" > 25-0° TYP. 55-11" RIGHT ELEVATION 2' 0" 2'-0° > 12- > 26-W JYPI, > 1 z-0 11 TMP' TYP' -�e^ srRUCTf1RAL SHEATHING 10 ,---------- ,,----- ---------- - •' I �� i^� S ° SoWV pt� r W MIN. >128 >26-0° 51'-0" REAR ELEVATION LEFT ELEVATION LEFT VOOL00 l dM9 DETAIL FRONT op" olo� REAR SHEATHING FRONT ELEVATION >o r ••`•: :'•• ��1 Z r •• Z� ••• ;� . ° 0 0 /.: �A J • Oi �d �`r D-aLLl • _o01 51 Q aj J W w �- uw 2 co 6r Q W MWVO 0- >- O r� v) U .J D� �U NUU0 RIGHT a Z - oz Ora ` U � LU Z z � � cn um: Z_w Z7Zz UO JLL J—O L)Fnoa� a�.0° UC cn oac g Z 0 0 mV o o J J C) 0 ru = r O S 0- m _ w 0 0 U m y s O y N cG d to 0 Zm�Zve 0 0 Q 3 tiJ N a r 5 fUi) C 2 m J r 3 LLI E Q Z� 0 @� N N ' a .�-) C Cu w LU I C'3 C'3 Z Q Q W DIAGONAL: 6/,I,, 75'-8 3116" r c cc � S53 BS54 S53 S53 2-BS54 +I S53 -v c/) S53 co BS54 BS54 A S53 S53 S25 2-BS54 51'-0', 2 S PACES 5 SPACES @ 4'4't @ 3'-511± 5 SPACES @ 4'-311± CD CO Lo rl- A r` cr)� Cn � co m CM co co C co � (cn i i) CA V) V) m Lo tco cr) CO om[) m (n Cn N (n Cn m (n Cn Cn m to in N Cn Cn Cn ------ ---- ��- --- - �� - - - - - --�� II II it II E _ I II II II II �1 II II I II I L II II L--------JL--------JL----- II I _ --J L - - - - - - - - - - J ------ - - - - -II - - - - - - - - - - - - - - - - - - I II II II r - - - - - - - - - - - II I '�i i'�--' I I I► 10'-011III 9'-7" I I III 10'-9" I I III 11'-2" I I II II II � II I I I I I I B I L - II II -----J L--------- L----- --J II L------ II I --J L----------- — — — — — — — - ----- --1 II r — — — — — — II ---I r------ -- II I II II I II II I I I I I I I I I co I II DROP 11 II � I I I I II II II A I II I i II I I I I o i t I I DROP I I I _--J L---------J I I I - ------ ---1 r---------- _ _ L-_ 344 BARS I I I I I II I F 6'-e" TYP. I I f II I F I I I II I II I II I ��-,�- II -- L-------- J FOUNDATION REQUIREMENTS: 1. THICKNESS T = 4" 2. BEAM WIDTH W = 10" 3. BEAM DEPTH D = 28" 4. AREA = 2251 SQ. FT. 5. EST. CONCRETE = 66 YDS. CAUTION: VIBRATE ALL CABLE LIVE AND DEAD ENDS TO ENSURE MAX. DENSITY CONCRETE, ESPECIALLY AREAS WHERE MULTIPLE STRANDS COME TOGETHER r I SLOPE I I I II II A II FL- -- -- -J L pq C CAUTION: IN THE EVENT THAT A CABLE PASSES THROUGH A PLUMBING OPENING, MOVE CABLE TO EDGE OF OPENING. CABLE SPACING CAN BE ADJUSTED, BUT IN NO EVENT CAN CABLE SPACING BE GREATER THAN 5'-0" O.C. A S24 +I S24 S25 w S24 a to C Lo S24 LOO [Jid I NOTES: 1. TO PREVENT SETTLEMENT DUE TO SOIL CONSOLIDATION, ALL EXTERIOR FOUNDATION BEAMS MUST BE FOUNDED A MINIMUM OF 12 'I INCHES INTO UNDISTURBED SOIL OR UNIFORMLY COMPACTED S� FILL. THE SELECT FILL SHOULD BE NON -EXPANSIVE SOIL WITH PLASTICITY INDEX BETWEEN 6 TO 14, AND SHOULD BE PLACED INC LIFTS OF 6 TO 8 INCHES AND UNIFORMLY COMPACTED TO A MINIMUM OF 95% OF ASTM D698 (STANDARD PROCTER) MAXIMUM DENSITY AT A MOISTURE CONTENT WITHIN 3% OF OPTIMUM. WHEN FOUNDATION sm SITE CONTAINS FILL (MAX. V-01, THE DEEPEN BEAM DETAIL SHOUL USED IN THESE FILLED AREAS. FOR SITES WHERE FILL IS GREATER THAN 3'-0', PLEASE CONTACT AGTM ENGINEERING LLC TO INCORPORATE PIERS INTO THE DESIGN. 2. ALL CONCRETE SHALL BE NORMAL WEIGHT, WITH MINIMUIM STRENGTH OF 3000 PSI AFTER 28 DAYS AND SHALL CONFORM TO ACI 318, ACI 301, AND ASTM C94, MOST CURRENT EDITIONS. 3. CONCRETE SHALL NOT BE PLACED WITH SLUMP GREATER THAN 5 INCHES. WATER SHALL NOT BE ADDED TO CONCRETE AT JOB SITE. 4. WHEN SPECIFIED ALL #3 BARS SHALL BE 40 GRADE STEEL AND ALL #4 OR LARGER BARS SHALL BE ASTM A-615 GRADE 60 5. PLUMBING MAY CROSS BEAMS BUT NOT BE PLACED IN BEAMS. B. ALL GRADE BEAMS AND SLAB AREA SHALL BE FREE OF ANY STANDING WATER AT THE TIME OF CONCRETE PLACEMENT. 7. 4" OF CUSHION SAND UNDER CONCRETE SLAB IS RECOMMENDED. 8. PROVIDE A 6 MIL POLYETHYLENE MOISTURE RETARDER BENEATH SLAB AREA. 9. ALL STRANDS 1 /2" DIA. - 270 K. 10. THIS FOUNDATION DESIGN IS CONSIDERED INVALID UNLESS ACCOMPANIED BY A LETTER FROM AGTM ENGINEERING LLC AUTHORIZING ITS USE ON A SPECIFIC LOT & BLOCK, OR ADDRESS. 11. PLANS CAN BE REVERSED ON LOT AT. BUILDERS DISCRETION. 12. PLANS ARE FOR STRAND AND BEAM PLACEMENT ONLY, SET FORMS, DROPS, HANDICAP RAMPS, ETC., BY ARCHITECTURAL FLOOR PLAN OR AS SPECIFIED BY OWNER/GENERAL CONTRACTOR. 13. AT CONTRACTORS OPTION, LIVE END AND DEAD END REVERSAL IS Lo PERMITTED. 14. AT CONTRACTORS OPTION, BRICK LEDGE MAY BE INCLUDED OR OMITTED AT EXTERIOR DOOR OPENINGS. fAN . DRAINAGE, DRAINAGE, DRAINAGE THE FINAL GRADE AROUND E FOUNDATION SHALL BE 8" BELOW THE TOP OF THE FOUNDATION D SLOPE AWAY FROM THE FOUNDATION A MINIMUM OF WIN 5'-0". 16. TO INSURE PROPER DRAINAGE AS STATED ABOVE, THE ELEVATION OF THE TOP OF SLAB SHALL BE A MINIMUM OF 12 INCHES ABOVE THE HIGHEST NATURAL GRADE ELEVATION AROUND THE PERIMETER OF THE SLAB. WITHIN A MIN. DISTANCE OF 5', STANDING WATER (PONDING) WITHIN 10' OF THE FOUNDATION PERIMETER WILL RESULT IN SOIL EXPANSION WHICH WILL CAUSE FOUNDATION PROBLEMS. 17. VIBRATE CONCRETE @ ALL CABLE LOCATIONS ESPECIALLY AT CORNERS WHERE SEVERAL CABLES ARE ANCHORED. MAXIMUM CONCRETE DENSITY IS REQUIRED TO INSURE THAT A "BLOW-OUT," DOES NOT OCCUR DURING CABLE STRESSING. a 18. THE FOLLOWING SYMBOL INDICATES DROP IN FOUNDATION. THE AMOUNT OF DROP AND EXACT LOCATION IS TO BE DETERMINED BY PLAN OR AS DIRECTED BY OWNER/CONTRACTOR. 0- STEEL REQUIRED. SEE DETAILS 17-SEE DEAD END ANCHOR DETAIL z _O cl) (� M w z 0=tip z �Lu=) =j�T O o w r�U0 `C9 Cc U) co 0I-" L)L) N z o Z U) U, a r t O U=z w Z r W W �Yzz zLo r w NU) O U 0 w c o 0 O U 2 T LL O Lo 1- O LL a g z 0 O w o -' cr 0 u o co Z o o J a w I- D Eli J J coE U UJ of c 0 cr 9 C �CD I--Ln N to 0 CID } D C tc\j 0 LI) rn o W �z .x.B ZLU \4/ 0 Ui wLL �H I 52 Os g 1,0co. to 10' 9" 2' 4' L 16' 3' 14' 6' ------------------------------- O -------- ---------------------------- ---------- O '1 so.so �_�� raxsa 7'a�SPro:so c --— ——— — —— — —{ 1 ip BDRM 2 1 8'0- CLG GAMEROOM I AC 8'0' CLG I 1 9,51 L 3' 8- m 16' 3' I I I 4'8• 2.0 4'6• F3'q' � ze N N S11 I ® 0116 b r� G TALL WALL DN 15R --------------- A I :a ENTRY I N N 18W CLG I 7' 4' 0' 3' BDRM 3 8'0" CLG PLANT SH 4' S' 4' 3 1/4' -5' 6 3/4' @ 10'0" 2' 6' 2' 0" 4' 7' 2' 0' 2' 6' 15' 11' 14' 3' 13' 7' 43' 9' BUILDING PERMIT '' CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 07-00003401 Date 12/17/07 Application pin number . . . 779237 Property Address . . . . . . 2461 NEWARK CIR Property ID: 184200-2501-0190 R #: R303657 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL DISTRICT Application valuation . . . . 173646 Owner Contractor ------------------------ ------------------------ GREENS PRAIRIE INVESTORS LTD CLASSIC CENTURY HOMES 4490 CASTLEGATE DR 5001 HWY 287 S COLLEGE STATION TX 778453388 ARLINGTON TX 76017 (817) 561-4369 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2631.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 4.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 441.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 535856 Permit Fee . . . . 93.00 Plan Check Fee .00 Issue Date . . . . 12/17/07 Valuation . . . . 173646 Expiration Date . . 6/14/08 Qty Unit Charge Per Extension BASE FEE 93.00 ---------------------------------------------------------------------------- Special Notes and Comments -Make sure 2nd floor windows are 24" Above Finished Floor. -Engineered Bracing *ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING ------------------------- -------------C °-- ---- ------ ------- BUILDING DEPT EP ENTATIVE : . e _�,. _ -Y_. _ APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION , 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number 07-00003401 Date 12/17/07 Application pin number . . . 779237 ------------------------- -------------------------------------------------- Special Notes and Comments UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) *PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY *PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. *Garage ceiling must have 5/8" Type X sheetrock when there is Habitable space above the garage. *PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE *Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. *ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS *ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq.-FEET *MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND *Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) *ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE *PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER *ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED *Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit *PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00003401 Date 12/17/07 Application pin number . . . 779237 ---------------------------------------------------------------------------- Special Notes and Comments OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES *PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION *ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING *IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. *REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT *A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 *THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' *ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP *MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC *If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. *ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE *POST PERMIT CARD ON JOB SITE TO BE VISIBLE FROM ROAD *WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI *RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE *For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating -- ---of 12 or more. ----------------------------------------��------------- BUILDING DEPT REPRESENTATIVE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 07-00003401 Date 12/17/07 Application pin number . . . 779237 ---------------------------------------------------------------------------- Special Notes and Comments *PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. *SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR *PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. *SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES *THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 200 TO 30% A .35 FACTO OR LOWER SHALL BE MET. *ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY *SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. *STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. *WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS *TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS *AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE *PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC ) *RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC *IF AN OPERABLE WINDOW IS MORE THAN 7211 ABOVE EXTERIOR FINISHED GRADE THEN THE LOWEST PART F THE WINDOW OPEN NG ----------------------------------------------7�- ------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number 07-00003401 Date 12/17/07 Application pin number 779237 ---------------------------------------------------------------------------- Special Notes and Comments MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE ROOM. *ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK *GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total Plan Check Total Grand Total 93.00 93.00 .00 .00 93.00 93.00 ---------------------------------------- ----- BUILDING DEPT,-PtPRESENTATIVE: APPLICANT: �%\ .00 .00 .00 .00 .00 .00 Jun •LU ut UL:U4p ucn - b/CS y f y oyu oozo P. :' CrTr dr CC: STotJ' Plm.gi�.d.+.'D;�XNYr✓ISSKvInX ADDRESS/LOCATION: APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77940 (979) 764-3570 (079) 794-3496 PAX WWW.CSTX.GOV 9L1/ I Af1-1. VA 17 L./ ./.n . DATE: APPLICATIO14 a U I TEMP POLE 0_ 0 F -Z 110 LOT ,A�EILOCK _ � SUBDN(SION_C&STL - ATL SEC/PH' r n �- Z BUSINESS/OWNER NAME; I�L,AS,j �C l �A ("),Q� 1CS PMONE: _I•&•a -� CONTRACTOR/HOMEOWNER:Ql E LUZ-pHONE: (- �5 CONTACT PERSON FOR REVIEW COMMENTS: r I PHONE: q'�gg0- FAX: "3�l 7 EMAIL: ELECTRICIAN: PLUMBER: HVAC: GOOD CENTS (Residential only): ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTIONSLAB ONLY DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING FOOL TENT/CANOPY DESCRIPTION OF WORK; PROPOSED USE: U�HOMEOWNER ASSOCIATIONIARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL ,�_ TEXAS ACCESSIBILITY STANDARD (PAOJT REGISTR ATION# EABPId.1MIA S VALUATION: $ q � TOTAL AREA 33� HEATED AREA: (p3 (Cost of bar and Materials) 1 PUBLIC SEWER SEPTIC/TREATMENT SYSTEM 'J It r SEWER TAP: ' WATER TAP: size SIZE OTHER TAP: TEMP PoLe GARAGE TYPE: sME Pc-i A NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: SINGLE [—] DOUBLE ATTACHED �C a�IN6 �t►�1Q�S rCt �n� TRIPLE a CARPORT 71 SIGNATURE OF APPLICANT: 'if Proposed wnrlc involy®s new oommemi 'tom en or Bade imRrovem c-�y�vaSioe�s 4®el� exls4ing commercial Property. building elevations are required. 04"40,009@•9 i66600eg060644OmO4666604,4'60460®646i866p 64ggP8440• Official Use Only 1 F/P Plans Examiner Zoning Official nlr Fire Marshall S+�Rt r g�'w4- /GmR� u//p Comments: — .� (j�OT �nl A- .�1'gwLtir Accra r NO / 40ee Jun 1U U/ 02:Ubp uch .- is1cs i UVU JUGJ Energy Conde Compdianci a Information Glazing of exterior walls Insulation R. value of exterior walls Insulation R value of ceiling I (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Clain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating . Protection Against Subterranean Termites Chemical Termiticide Treatment (Soil TreAment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ® Physical Barriers ® Other *Verification of Applieatlon shall be submitted Eo the of College Station Building Department prior to issuance of the Cerdflsate of Occupancy. V PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS "W CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& DevelopmentServitet COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# D _ 2 O / DATE: 11 _ ' _ U BUILDING ADDRESS: A L/ ' �ew�c_ r I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck O E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. / K OK u PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& DevelopmentServitei COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details NAW 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow ed e 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NAXV B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/ K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 A/ K Does not block any water course or divert any flow Elevation certificate needed K "APPROVED PLANS PER IRC SECTION R106.3.1." EXAMINER Z - �/- 0!7 DATE