Loading...
HomeMy WebLinkAboutRES2007-03396, 07-3397tie, pip) City of College Station 1101 TEXAS AVENUE—' COLLEGE STATION TX 77840 T E M P O R A R Y - C O T E M P O R A R Y Issue Date . . . . . . Expiration Date . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . . . 2/27/08 3/12/08 650730-0408-0280 3907 VICTORIA AVE COLLEGE STATION TX 77845 WESTFIELD VILLAGE #4, BLOCK 8, LOT UNKNOWN Pb D C /J BCS DEVELOPMENT CO i' STYLECRAFT BUILDERS 979 690-1222 Application number 07-00003396 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone Special conditions 1. Need proper drainage at.front of house. j ^ � Approved . . . . . . B`i ilding Official VOID UNLESS SIGNED BY BUILDING OFFICIAL PREPARED 2/22/08, 12:03:03 INSPECTION TICKET PAGE 16 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/22/08 ------------------------------------ ----------------------------------------------------------- ADDRESS . : 3907 VICTORIA AVE SUBDIV: CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER BCS DEVELOPMENT CO PHONE PARCEL 650730-0408-0280 APPL NUMBER: 07-00003396 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------- PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/04/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 12/04/07 AP December 4, 2007 8:31:14 AM acarter. 12/04/2007 03:00 PM RH PDA Strings up, slab ground installed. B120 01 12/21/07 OC BLDG, FRAMING -PARTIAL TIME: 17:00 12/21/07 AP December 21, 2007 11:00:27 AM glsouth. apa frame December 21, 2007 2:43:02 PM kwolfe. B115 01 1/11/08 OC BLDG, FRAMING TIME: 17:00 1/11/08 AE January 11, 2008 10:15:51 AM kwolfe. O1/11/2008 04:10 PM OC PDA glass in stairs needs to be tempered by c.o. B130 01 1/15/08 RH BLDG, INSULATION TIME: 17:00 1 08 AP January 14, 2008 3:54:07 PM acarter. B125 01 2/22/08 I BLDG, FINAL TIME: 17:00 February 22, 2008 10:13:06 AM acarter. -------------------------------------- COMMENTS AND NOTES-------------------------------------- ��uypC.o. fI Name of PWS Location of Service Customer Service Inspection Certificate City of College Station PWS I.D. # 0210002 on or nsp New Construction xis g ervice where contaminant hazards are suspected Major renovation or expansion of distribution facilities Oscar Chavarria upon inspection of the private water distribution facilities connected to the afore mentioned public water supply do hereby certify that, to the best of my knowledge: (1) No direct connection between the public drinking water supply (2) Compliance Non —Compliance and a potential source of contamination exists. Potential sources of Contamination are isolated from the public water system by an air gap or an appropriate backflow prevention assembly in accordance with Commission regulations. (2) No cross -connection between the public drinking water supply and a private water system exists. Where an actual air gap is not maintained between the public water supply and a private water supply, an approved reduced pressure - zone backflow assembly is properly installed and a service agreement exists for an annual inspection and testing by a certified backflow prevention assembly tester. (3) No connection exists which would allow the return of water used for condensing, cooling or industrial processes back to the public water supply. (4) No pipe or pipe fitting which contains more than 8.0% lead exists in private water distribution facilities installed on or after July 1, 1988. (5) No solder or flux which contains more than 0.2% lead exists in private water distribution facilities installed on or after July 1, 1988. I further certify that the following materials were used in the installation of the private water distribution facilities: Service lines: Lead Copper PVC Other Solder: Lead Lead -Free Solvent Weld Other I recognize that this document shall become a permanent record of the aforementioned Public Water System and that I am legally responsible for the validity of the information I have provided. Remarks: I-2625 Signature of Inspector Registration Number Plumbing Inspector T.P.I Title Type of Registration Date * CERTIFICATE MUST BE KEPT FOR AT LEAST 10 YEARS * 979 690 0348 02/27/2008 10:45 #368 P.002/004 From:STYLECRAFT BUILDERS INC •t "Shielding & Protecting Homes Against Pests" 01 - �03% 12� Renewable 5 Year Subterranean Termite Retreatment Agreement (Does not cover any other species of Termites) This agreement provides for retreatment only of the infested areas covered under the original treatment areas (See Graph). Customer Name Date Billing Name if different Street Address of treated structure Billing Address if different City State Zip Code City State Zip Code Initial Termite Cost $ —0 Home Phone Work Phone Additional Renewals Paid Other ram Type of Treatment Partial Bait YPre-Treat Tax Treatment for Y Prevention Control of Subterranean Cash_Check# Total $� p Termites Payment $ Notes: Balance S Credit Card: Type Exp. Date Card Number 5 Year Subterranean Termite Retreatment Guaraotee• RP Lee Termite and Pest Control will retreat the structure for Subterranean Termites, at no cost to the customer, if an infestation of Subterranean Termites is found, as long as the original treatment is paid in fidl and the customer is current on their yearly renewals. This Agreement will expire in one (1) year unless the customer elects to,pay the yearly warranty fee. The guarantee can be renewed for up to five (5) years by paying the yearly warranty fee. RP Lee Termite and Pest Control may approve additional warranty years after the five (5) years with an additional increase in the yearly warranty fee. The guarantee does not cover any damages to the structure or contents of the customer- The customer agrees to control all conducive conditions that may cause reinfestation. If the structure is modified, added on to, altered, or if the soil treatment around the structure is removed the customer must contact RP Lee Termite and Pest Control and pay for additional"ieatment in order to keep the guarantee in effect. If the customer does not pay for additional treatment the retreatment guarantee can be cancelled- a v Renewal Fee: Customer may elect to renew the retreatment guarantee for additio years- The renewal fee is $ Jar, phis tax. The renewal fee is due on or before the annual anniversary date or paid $ plus tax every third (3) month with inspection. Maitttaihin-g the Guarantee: The customer agrees to correct all condusive conditions, at owner's expense, as they exist or as they occur in the future m order for the guarantee not to be cancelled Customer will make the structure available for inspections and treatments as requested by RP Lee Termite and Pest Control. ReinsMtion: RP Lee Termite and Pest Control will reinspect the structure at customers request or any other times •RP Lee Termite and Pest Control deems necessary- RP Lee Termite and Pest Control ieccmmends that the customer call and set up an annual inspec- tion at the time of eustomers yearly renewal. cans e . This agreement may be transferred to a new owner with the,payment of a transfer fee of $_ , copy of the Wood Destroying Insect Report from the sell, and approval of RP Lee Termite and Pest Control. This Subterranean Termite Retreatment Guarantee does not prevent and is not intended to control other forms of Termites mood Formosan_ etc.). Wood Boring Beetles, CaMenter Ants Carpenter Bees Wood Rot Fungus Decay, or any other woad destroying inseets or orYanisms: Arbitration: In the event of any dispute arising out of this agreement or any other services performed or not performed the parties above agree to participate in mediation through and in accordance with the commercial mediation rules of the American Arbitration Association. The Arbitrator shall consider the legal defenses raised in the arbitration, and the decision of the arbitrator shall be final, binding, non -appealable and may be entered and enforced in any court having jurisdiction in accordance with the Federal Arbitration Act Limitation of Liability Landscaping and grass next to the slab may be damaged during treatment, carpet may need to be pulled up in certain areas around the home, drill holes may need to be made in floor coverings such as file or linoleum or in cabinets next to pipe areas, and holes may need to be cut in walls. Customer agrees not to hold RP Lee Termite and Pest Control liable for these damages, or treatment techniques, or other damages that may occur during treatment Agreement: This Agreement -shall -be -the -entire agreement between customer and RP LeeTermite and Pest Control.. If any partof this agreement is found to be invalid it shall not affect the validity of any other part of the Agreement We are licensed by the Structural Pest Control Board-- 333-Guadalupe Suite 1530 Austin. TX 78701512-305-8g RP Lee erm � T& Pest Control Cert. Apl.# Customer Sig'dature Date From:STYLECRAFT BUILDERS INC 979 690 0348 02/27/2008 10:45 #368 P.003/004 SUBTERRANEAN TERMITE PPc-CONSTRUCTION TREATMENT Dt! "LOSURE FOR EACH ESTIMATi Liceni. nd regulated under the Texas Structural Pest Control RP LEE TERMITE & PEST CONTROL PO Box 9423 College Station, TX 77842 • (972) 690-8622 • TPCL #11486 - CUSTOMER INFORMATI N: Name: J% erg, 0 Phone #1: Phone #2: Address: CityShe: Zip Code: Location to be Treated: .J T fl v E r 7d4/ A LA. 5 7,C 1 %u e5 For all treatments There will be a diagram showing exactly what will be treated prior to the beginning of treatment Review the pesticide label provided to you at this time for minimum treatment standai Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the law. Review the consumer information sheet for further information. If have any questions, contact the pest control comoamv or the Texas Structural Pest Control Board, P.O. Box 1927, Austin, TX 78767-1927. Telephone number (512) 305-8250. Before conducting a termite preconstruction treatment the company will present a complete diagram of the structure inducting construction details. When construction prevents performance of a treatment, in accordance with a bid for full treatment, any change to a partial treatment by the company providing the treatment will be permitted if the owner of the structure or the person in chargc the construction and the certified applicator for the pest control company sign a statement attesting to the construction conditions. The agreement must be attached to the contract with an amen( diagram showing the exact areas to be treated. Copies must be serd to the owner of the property within seven days of the application. Diagram of Structure(s) and Proposed Area(s) To Be Treated notes:.���e4/1C W IMMfe"I ■■■W■0■�■■■■■W �t�■■■■■■■�■■■[ ■■■■■■■■■■■i•■■■■SEEN v amal NOW ..�.uric.d.�■■S�■■■■■■■■I•■WESS■S■■■C■■ /ES SEES■ ■W/■■iSS■■S ESSS SE E■SE■E i�■E�■O■■i ■■� ■■■.■■■■.■ ■■■■■■■�.■■E�...■E. E.■■WE■..■s.■■■E..■WE■WE■11W■ ■■.SEES .... .uW.,. NEE■E■I■W■■ ■■■W■■■■�■W t■ ■■■■■■E ■■EEE■■■■ " WEE ■■■i■.■w■■■CEa■�E�E■.C...■W .■E.NEW■ MEN so �■i■�i �� ■�■■EW■■■iiis����.i�� Aiii��i �■uu■n■i■�E�i%mo ■■E■■■■E��■■�■E�■i�ii■�■�ii ri■iii�i�■s■iiii■ii■iinii■■�iE■a ■p ■WOKE■ ENE■■SNEEq■■�■iiHEE■■SSSSWES■�S■SE1■S �j � v►,�.---_..i r�.r/rEEE■■E■■■■q�w■SEEN � 0W■S■■■■W■■1S■Sia■!■� ■■■■■■■■p■S■■.SSSE■■SWE i`. ■■W■SE■�■■Eu■N■oSSv;I■■■■SS■ i�Ar ■■i■■■ENEEZEEMIZE 111 E 1■'■■■�11111111■.n>i smog" MEN EEMENE■■iti■EEEE■NEE m SEES ■■S■■W■E■■W■ENW■ "■■uE���ii�1■'■i'>v�i'W'i■�'ii■ii■�i■iin■■°'i■"i■i■'O■n ■ im■i mmE ■iiiaii■�iii�iiii■�iiiiiiiii■i■■u��i■�i■��rr ■p■E�S■�E■p'■'E■u tl�Wtmlii■■ii■Ei�ii■�iiii■�iii�i�■i■�■�■E■iidE■■m■� ■■■ ■ �■■■SE■SEE■EEO■■E■S■EEESSSE■E)•EE■■■■■■■■■E!■S■■■■■!.■■ ■■1■■CSEiS1Wn■/0■ WE■nW■■W■■■u■EEWE■■nu■ Type of treatment proposed: (check all that apply): ❑ Full pi Partial YKNood O Bait ❑ Commercial &tangle Family Total square feet to be treated: �� . Total linear feet to be treated: ��L. Approximate measurements of structure(s) to be treated: .A label of termiticide(s) is attached. The percentage of.the termitidde(s) to be applied at this location Estimated amount of tern itiade to be applied: gallon(s), THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE IS ATTACHED ON BACK (SPCBID4). THE BOARD -APPROVED SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUCTION TREATMENT SERVICE. Complete details of warranty (rf any) inducting time period of warranty, renewal options and cost, and obligations of the contracting parties is attached... If the warranty does not include the entire structure treated, the areas included in the warranty are (specify): A consum r information shhea6 also attached. 2l f O z l Signature of Vor Technician Printed Name Date Signatke of Custoggr Verifying Receipt of This Document Date nEM 6; U .Wd01WW White Copy -Service Provider Yellow Copy- Cusinmer Fah DesWed end Rita y&-. Cw—imdom tA6b7B2�2/S, 0W., TX02d s Service Treatment Invoice Route: Map Code: Start Time: tn/pm Finish Time: —am Type of Servlce:. nitla Regular Follow Up One Time Charity Service Address Name: 5�f/�� rtAr Address: 3TQq -u City: _ C . S TX �13 Phone: Date: Z- Z-0�' Appolnt.Time: am/pm Frequency: BM Q S Y Structure: I�d Crawl P/B Combo Pets: Dog(s) Cat(s) Bird(s) Fish A, e_* Cost of Service Tax Total Due Payment T — Balance PEST PROBLEMS: /I,��,�>�•,(,% DIRECTIONS l INSTRUCTIONS: Billing: EQUIP. METH. LOCATION(S) PRODUCT WOOD DESTROYING INSECTS rr ! Shielding & Protecting Homes Against Peste , TPCL Nii486 QTY $ Payment by: $ Cash .❑ $ "" Check ❑ #. $ ?r 141. Credit Card ❑ TARGET PEST(S) PAYMENT DUE, I.. -. UPON RECEIPT'.l TermidorSC-Flproni1.06% Subterranean Termites, Ants Size of Tank Posted Termitior SOW Fipronll .06% Subterranean Termites. Size of Tank Posted —�� Bora-care-Dlsodium Octaborate Tetrahydate 50% —Z Subterranean/Formosan/Dryaood Termites, Carpenter Ants, Beetles, Posted. •.' F1,EAS MI ROD E NT AT4, MONITORS OTHER Invader HPH-Baygon 1% Demon WP-Cyano-Phenoxypheayl Dimethycyleyclopropanecarhozylate 1% Tempo Ultra WP-Cyfluthrin .625% (Rest) (gen. surface spray, spot, mist, crack & crevice) Talstar EZ Blfenthrin .2% Maxforce-Hydramethylon 1%-2.15% Cykick CS Cyfiuthrin .05% Phantom S% Tengard-Permethrin .5% Suspend SC-Deltaneturin 4.75% (REST) Nyguord-Methyletnoxy Io% (REST) Excite R Pyrethtin .05% Fastrac-Bromethalin .01% Bait Station-Large/Small Glue Boards Speckoz-Pyrocide.50% Bifen 1/T Bifenthrin .06% Carpenter Ants, Spiders, Crickets, Millipedes, Beetles, Termites. Cockroaches, Millipedes, Sowbugs, Flles,Tlcks, Mosquitos, Plllbugs, Silverfish, Bees,Ants, Carpenter Ants, Scorpions, Spiders. Ants (Except Pharaoh), Cockroaches, Crickets, Earwigs, Millipedes, Flies, Fruit Files, Beetles, Pfilbugs, Silverfish, Spiders, Gnats, Hornets, Wasps, Yellow Jackets. Ants, Centipedes, Cockroaches, Crickets, Grasshoppers, Scorpions, Ticks, Silverfish, Spiders. Pharaoh Ants, Crickets, Carpenter Ants, Lg. Roaches, Variety ofAuts. Spiders, Scorpions, Ants, Carpenter Ants, Carpenter Bees, Roaches, Crickets, Silverfish. Pbaroh Ants, Variety of Ants, Roaches. Pleas,Ticks,Auts, Centipedes, Carpenter Ants, Bees, Wasps, Carpenter Bees, Cockroaches, Crickets, Files, F.nrtvigs, Millipedes, Beetles, Pillbugs, Fleas, Bees, Beetles. Roaches, Crickets, Lice, Flies, Scorpions, Ticks, Wasps. IGR-Growth Regulatol'Fleas, Roaches, Crickets, Flying Insects, Stored Product Pesis. Fleas. Mice, Rodents, Rats. Mice, Rodents, Rate, Bug Monitol•a. Houseflies, Mosquitos, Moths, Fleas, Wasps, Hornets, Ticks, Cockroaches. Spiders, Ants, Roaches, Silverfish, Earwigs, Fleas, Scorpions Eq ment: A -Compressed Sprayer P-Power Sprayer B-Beit Dispenser BS-Bait Station BT-Bait Trap D-Aerosol Can G-Glue Board R-Hand Duster S-Spreader F-Fogger FM-Foamer AC-Actisol unit Other ations • I -Kitchen 2-Bath(s) 3-&:drooms 4-Dining Room 5-Utility 6-Storage 7-Common Areas &Garage 9-Perimeter of Structure 10-Attic l l-Yard 12-Under Home 13-Warehouse 14.Otitce 15-Exposed Wood 2' up from Slab Other NMethod of TYeatmentsm CC -Crack & Crevice SS -Sub -Slab Injection VT -Void Treatment BP -Bait Placement BS-Broadcast Spray PB-Perimeter Barrier BV-Brick Venire WT-Wood Treatment ! ' PRECAUTIONS: Do not touch treated areas till dry. Do not tamper with bait stations. Ventilate rooms after treatment. Keep pets away until pesticides have dried. Licenced b the tructural Pest Control Board - 333 Guadalupe, Suite I-530 • Austin, TX 78701. 512-305-8250 , SERVICE TECHNICIAN: d' . CUSTOMER SIGNATURE: P/,l '21° /(f DATE: T 0 C/) n-I C-D D n 00 C 0 M Cn z c-D CD v co 0-) co CZ> CZ) co 16' ONC. o D IVE N 48-41'04" W TRUC 3 `O/�,N T♦A UT 1/2" DIA. SMOOTH DOWEL 2'-0" LONG W/ PVC CAP - PLACE IN SLAB OR DRILL 9" INTO EXISTING 1 O' REAR PUE 6' a GRADE BEAM. TAPE CAP TO LEAVE TOOL EDGE E.J.T. 1" ® END OF ROD a 0' EARS TB - 4" THICK PAVING 3000 PSI REINF. W/ #3's ®ta o.c.E.w. BUILD I N G LINE: F NCE W ONE CAR L� �J • a@ MID DEPTH USE CHAIR SUPPORTS ° GATE GARAGE 5 DISCONTINUE REINF. 0 E.J. 1X REDWOOD DIVIDER CONTRACTION JOINT WHEN S A�� 1 DRIVE < 1 6' WIDE a S 4. m kbc_ck ° p 4 4" THICK 3000 PSI CONC. � S2� D SECTION "ID"" C ° REINFORCE W/ #3 BARS N.T.S. p 18' D.C.E.WW. N 'o INSTALL EXPANSION JOINT p CONTRACTION JOINT co MID -DRIVE IF OVER 45' o CONTINUE REINFORCEMENT ° p� �. THROUGH KEYWAY O 1 Z:, 24'-1 1 Z" Z INSTALL METAL KEYWAY - oQF///,,RESIDENC PROPOSE 4" THICK PAVING 3000 PSI EXP. JOINT W/ 3/8' DIA. r om -� ONE CHAIR PER p SLICK DWLS. 18" O.C. o•,i 4 SO. FT. MIN. REINF. W/ #3's ® 18" O.C.E.W. ° W/ SLEEVES ONE SIDE MID DEPTH USE CHAIR. SUPPORTS PROPERTY LINE ° C SECTION "C" p 20' FO UE N.T.S. Q RC SETBA 3907 VICTORIA AVENUE WESTFIELD VILLAGE 3/8" DIA. DOWEL W/ SLEEVE. -LOT - 28 DRILL INTO EXISTING SIDEWALK BLOCK - 8 %ST NG sioEwn�K �a 4" THICK 3000 PSI CONC. REINFORCE W/ #3 BARS a B 35. 0' PHASE 4 , (9) 18" O.C.E.W. N 48°4 '0 " W 1 X REDWOOD DIVIDER T,° ° 11. - VINYL FENCE SECTION IIBIN.r.s. VERIFY TH— B SIDEWALK CITY SIDE WALK IN FIELD i 3907 6, ° Q 3/8- DIA. DOWEL W/ SLEEVE. p DRILL INTO EXISTING CURB O, B O MAIL BOX / 8" X 8" BEAM ° W/ 4 #5 REBAR I p ° o A SECTION "A" _ N N.T.S. A ' -r I LAYDOWN CURB DETAILS ' I 07152 EA lomm w U i O cn MASTER CREATED: 11/14 PRE -CON: REVISED: ISSUED: PRINTED: 11/14 Lu t=— CD SCALE: - 1 •-za C-1 WF0983847 / 001 City of College Station PAGE 1 REQ. DATE: 11/27/07 11/27/07 9:23:14 LOCATION: 3907 VICTORIA AVE LOC ID: 203768 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 11/27/07 SCHED COMPLETION: 11/27/07 ******************************************************************************** JOB ORDER RESULT COMMENTS City of College Station — 1-9Z TEXAS AVENUE COLLEGE STATION TX 77840 T E M,P O R A R Y CO T E M P O R A R Y Issue Date . . . . . . 2/27/08 Expiration Date . . 3/20/08 Parcel Number . . . . . Property Address Subdivision Name Legal Description . . . Property Zoning 650730-0408-0280 3907 VICTORIA AVE COLLEGE STATION TX 77845 WESTFIELD VILLAGE #4, BLOCK 8, LOT 28 PLANNED DEVL DISTRICT Owner . . . . . . . . . BCS DEVELOPMENT CO Contractor . . . . . . STYLECRAFT BUILDERS 979 690-1222 Application number 07-00003396 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . Special conditions . . 1. Need proper drainage at front of house. Approved . . . . . . AV Building Official VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING PERMIT CITY OF COLLEGE STATION 110�...TE�AS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 07-00003396 Date 11/26/07 Application pin number . . . 521364 Property Address . . . . . . 3907 VICTORIA AVE Property ID: 650730-0408-0280 R #: R303410 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL DISTRICT Application valuation . . . . 98076 Owner Contractor ------------------------ ------------------------ BCS DEVELOPMENT CO STYLECRAFT BUILDERS 4090 SH 6 S 4090 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 1.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1486.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number 536920 Permit Fee 456.00 Plan Check Fee .00 Issue Date . . . . 11/26/07 Valuation . . . . 98076 Expiration Date 5/24/08 Qty Unit Charge Per Extension BASE FEE 260.00 49.00 4.0000 THOU BLDG, VAL 50001-100000 196.00 ---------------------------------------------------------------------------- Special Notes and Comments -Narrow Wall Bracing Fully Sheathed with 18" Minimum APA -----Garage Framing - ------------------------------�������---------------- BUILDING DEPT RFP�ESENTATIVE: / j 1 71 --, l' e APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00003396 Application pin number . . . 521364 Page 2 Date 11/26/07 Special Notes and Comments -Garage Ceiling to have 5/8" Type X Ceiling Sheetrock -Make Sure to have 6'-8" Clearance above Toilet, Under Stairs ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. Garage ceiling must have 5/8" Type X sheetrock when there is Habitable space above the garage. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Includi g One Within 25' Of Outside A/C Unit �- BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number 07-00003396 Application pin number . . . 521364 Page 3 Date 11/26/07 Special Notes and Comments PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12".AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKE ON Sf LO TED JIFF BUILDING DEPT REPRES,F.N%�,TIVE: — APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Page 4 Application Number . . . . . 07-00003396 Date 11/26/07 Application pin number . . . 521364 Special Notes and Comments THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 200 TO 30% A .35 FACTO OR LOWER SHALL BE MET. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC ) RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING MUST BE AT LEAST 24" ABOVE THE FINSHE FLOOR FROM INSIDE THE ------------------------------------------- ---- `------------ BUILDING DEPT REPRE N'I TIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 07-00003396 Date 11/26/07 Application pin number . . . 521364 ---------------------------------------------------------------------------- Special Notes and Comments ROOM. ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ------------------------------------------ Other Fees . . . . . . . . . --------------------------------- SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged --------------------------- Paid Credited ------------------------------ Due Permit Fee Total 456.00 456.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1206.00 1206.00 .00 .00 BUILDING DE APPLICANT:- TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00003397 Date 11/26/07 Application pin number . . . 603673 Property Address . . . . . . 3907 VICTORIA AVE Property ID: 650730-0408-0280 R #: R303410 Application type description TEMP POLE Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL DISTRICT Application valuation . . . . 0 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S 4090 SH 6 S COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 690-1222 ---------- ----------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit pin number . 536938 Permit Fee . . . . 20.00 Issue Date . . . .-11/26/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited ------------------------------ Due Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------------------------------ ---- ------------- BUILDING DEPT EP*�E�TTATTY-F-. APPLICANT: For office Use APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE (*/z COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning c5 Developmmt Services WWW.CSTX.GOV DATE: APPLICATION # TEMP POLE # ADDRESS/LOCATION: 31n7 VI(,j-0g-IL` Je / LOT 28 BLOCK VgUBDIVISION 1 FIELD \/tLLAC E `✓5EC/PH � ✓ BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTACT PERSON FOR REVIEW COMMENTS: ERIC WIVAGG PHONE: 690-1222 ext. 120 FAX: 690-0348 EMAIL: ewivagg(a)_stylecraft-builders.com ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION ` SLAB ONLY DUPLEX (Landscape Plans) . REMODEURENOVATION" SWIMMING POOL TENT/CANOPY u DESCRIPTION OF WORK: Conventional Framing PROPOSED USE: Single Familv Residence WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPS [j4 ENGINEERED ❑ HOMEOWNER ASSOC IATION/ARC HITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ qS / 076 V-- TOTAL AREA: 11343 HEATED AREA: /48(- (Cost of Labor and Materials) 1�/ (� % �X PUBLIC SEWER 1 ❑ SEPTIC/TREATMENT SYSTEM ,Dp OX SEWER TAP: 4" SIZE 15) �X WATER TAP: %11 SIZE /01,01:1 OTHER TAP: SIZE X TEMP POLE 11' GARAGE TYPE: SINGLE �� ATTACHED I n J SIGNATURE OF APPLICANT: *If proposed work involves new commercial onstru commercial property, building elevations are required. Official NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: 2• INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: DOUBLE E] I$TACHED FI Composition TRIPLE CARPORT F1 // or facade improvements/rdnovations to an existing Only �,Ls Plans Examiner Zoning Official cl"04e' a�Sve -hE let' del°k) Co ments: ILc ES or NO - zJ'-, 44o" GA e, 11�r Fir Marshall /�oisfu�a, ��irt Aou/ G� Im Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating Protection Against Subterranean Termites ❑ Chemical Termiticide Treatment (Soil Treatment) % R13 R30 / .35 .53 / R6 13--' Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& DevelopmentSemicei COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# o - 3�' DATE: 11 - Z4-07 BUILDING ADDRESS: .3 0 ' cAnaa Al I. Foundation Requirements- Minimum City Foundation Standards NA/gAq A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated U00K II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck K E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. /OK N)OK S CITY OF COLLEGE STATION Planning d Development Servicef PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details NAtW 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5.. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements AJOK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NA/ 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location CITY OF COLLEGE STATION Planning d Development Service) PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NA/ A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow Elevation certificate needed N6101K "APPROVED PLANS PER IRC SECTION R106.3.1." LANS EXAMINER DATE REScheck Software Version 3.7.3 Compliance Certificate Project Title: Plan # 1486A Report Date: 11/14/07 Data filename: S:\ACADWrchived\Old REScheck\1486_3907 Victoria.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 11% Heating Degree Days: 1788 Construction Site: Owner/Agent: 3907 Victoria College Station , TX 77845 Maximum SHGC: 0.40 Your SHGC: 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Cathedral Ceiling (no attic): Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame:Double Pane with Low-E: SHGC: 0.40 Door 1: Solid: Door 2: Glass: SHGC: 0.40 Floor 1: Slab-On-Grade:Heated: , Insulation Depth: 0.0' Air Conditioner 1: Electric Central Air: 13 SEER Furnace 1: Forced Hot Air: 80 AFUE Permit # Permit Date Designer/Contractor: Stylecraft Builders 4090 S. Hwy 6 South College Station, TX 77845 1414 30.0 0.0 49 72 19.0 0.0 4 1888 13.0 0.0 137 181 0.670 121 20 0.500 10 18 0.580 10 145 0.0 151 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The osed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with the ma datory is I' etl in the REScheck Inspection Checklist. S1YLEC2A� 11 / 07 Builder/Designer Company Name Dad Plan # 1486A Page 1 of 1