HomeMy WebLinkAboutRES2007-03396, 07-3397tie, pip)
City of College Station
1101 TEXAS AVENUE—'
COLLEGE STATION TX 77840
T E M P O R A R Y - C O
T E M P O R A R Y
Issue Date . . . . . .
Expiration Date . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . . .
2/27/08
3/12/08
650730-0408-0280
3907 VICTORIA AVE
COLLEGE STATION TX 77845
WESTFIELD VILLAGE #4, BLOCK 8,
LOT
UNKNOWN Pb D C /J
BCS DEVELOPMENT CO i'
STYLECRAFT BUILDERS
979 690-1222
Application number 07-00003396 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone
Special conditions
1. Need proper drainage at.front of house.
j ^ �
Approved . . . . . .
B`i ilding Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
PREPARED 2/22/08, 12:03:03 INSPECTION TICKET PAGE 16
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/22/08
------------------------------------ -----------------------------------------------------------
ADDRESS . : 3907 VICTORIA AVE SUBDIV:
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER BCS DEVELOPMENT CO PHONE
PARCEL 650730-0408-0280
APPL NUMBER: 07-00003396 RESIDENTIAL, 1 UNIT DETACHED NEW
-------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
12/04/07
RH
BLDG, FOUNDATION -SLAB TIME: 17:00
12/04/07
AP
December 4, 2007 8:31:14 AM acarter.
12/04/2007 03:00 PM RH PDA
Strings up, slab ground installed.
B120 01
12/21/07
OC
BLDG, FRAMING -PARTIAL TIME: 17:00
12/21/07
AP
December 21, 2007 11:00:27 AM glsouth.
apa frame
December 21, 2007 2:43:02 PM kwolfe.
B115 01
1/11/08
OC
BLDG, FRAMING TIME: 17:00
1/11/08
AE
January 11, 2008 10:15:51 AM kwolfe.
O1/11/2008 04:10 PM OC PDA
glass in stairs needs to be tempered by c.o.
B130 01
1/15/08
RH
BLDG, INSULATION TIME: 17:00
1 08
AP
January 14, 2008 3:54:07 PM acarter.
B125 01
2/22/08
I
BLDG, FINAL TIME: 17:00
February 22, 2008 10:13:06 AM acarter.
-------------------------------------- COMMENTS AND NOTES--------------------------------------
��uypC.o. fI
Name of PWS
Location of Service
Customer Service Inspection Certificate
City of College Station PWS I.D. # 0210002
on or nsp
New Construction
xis g ervice where contaminant hazards are suspected
Major renovation or expansion of distribution facilities
Oscar Chavarria upon inspection of the private water distribution facilities connected to the
afore mentioned public water supply do hereby certify that, to the best of my knowledge:
(1) No direct connection between the public drinking water supply
(2) Compliance Non —Compliance and a potential source of contamination exists. Potential sources of
Contamination are isolated from the public water system by an air gap or
an appropriate backflow prevention assembly in accordance with
Commission regulations.
(2) No cross -connection between the public drinking water supply and a private
water system exists. Where an actual air gap is not maintained between the
public water supply and a private water supply, an approved reduced pressure -
zone backflow assembly is properly installed and a service agreement
exists for an annual inspection and testing by a certified backflow prevention
assembly tester.
(3) No connection exists which would allow the return of water used for condensing,
cooling or industrial processes back to the public water supply.
(4) No pipe or pipe fitting which contains more than 8.0% lead exists in private
water distribution facilities installed on or after July 1, 1988.
(5) No solder or flux which contains more than 0.2% lead exists in private water
distribution facilities installed on or after July 1, 1988.
I further certify that the following materials were used in the installation of the private water distribution
facilities:
Service lines: Lead Copper PVC Other
Solder: Lead Lead -Free Solvent Weld Other
I recognize that this document shall become a permanent record of the aforementioned Public Water
System and that I am legally responsible for the validity of the information I have provided.
Remarks:
I-2625
Signature of Inspector Registration Number
Plumbing Inspector T.P.I
Title Type of Registration
Date
* CERTIFICATE MUST BE KEPT FOR AT LEAST 10 YEARS *
979 690 0348 02/27/2008 10:45 #368 P.002/004
From:STYLECRAFT BUILDERS INC
•t
"Shielding & Protecting
Homes Against Pests"
01 - �03% 12�
Renewable 5 Year
Subterranean
Termite Retreatment
Agreement
(Does not cover any other species of Termites)
This agreement provides for retreatment only of the infested areas covered under the original treatment areas (See Graph).
Customer Name Date Billing Name if different
Street Address of treated structure Billing Address if different
City State Zip Code City State Zip Code
Initial Termite Cost $ —0
Home Phone Work Phone Additional Renewals Paid
Other ram
Type of Treatment Partial Bait YPre-Treat Tax
Treatment for Y Prevention Control of Subterranean Cash_Check# Total $� p
Termites Payment $
Notes: Balance S
Credit Card:
Type Exp. Date Card Number
5 Year Subterranean Termite Retreatment Guaraotee• RP Lee Termite and Pest Control will retreat the structure for Subterranean
Termites, at no cost to the customer, if an infestation of Subterranean Termites is found, as long as the original treatment is paid in fidl
and the customer is current on their yearly renewals. This Agreement will expire in one (1) year unless the customer elects to,pay
the yearly warranty fee. The guarantee can be renewed for up to five (5) years by paying the yearly warranty fee. RP Lee Termite
and Pest Control may approve additional warranty years after the five (5) years with an additional increase in the yearly warranty fee.
The guarantee does not cover any damages to the structure or contents of the customer- The customer agrees to control all conducive
conditions that may cause reinfestation. If the structure is modified, added on to, altered, or if the soil treatment around the structure
is removed the customer must contact RP Lee Termite and Pest Control and pay for additional"ieatment in order to keep the guarantee
in effect. If the customer does not pay for additional treatment the retreatment guarantee can be cancelled- a v
Renewal Fee: Customer may elect to renew the retreatment guarantee for additio years- The renewal fee is $ Jar, phis tax.
The renewal fee is due on or before the annual anniversary date or paid $ plus tax every third (3) month with inspection.
Maitttaihin-g the Guarantee: The customer agrees to correct all condusive conditions, at owner's expense, as they exist or as they
occur in the future m order for the guarantee not to be cancelled Customer will make the structure available for inspections and
treatments as requested by RP Lee Termite and Pest Control.
ReinsMtion: RP Lee Termite and Pest Control will reinspect the structure at customers request or any other times •RP Lee Termite
and Pest Control deems necessary- RP Lee Termite and Pest Control ieccmmends that the customer call and set up an annual inspec-
tion at the time of eustomers yearly renewal.
cans e . This agreement may be transferred to a new owner with the,payment of a transfer fee of $_ , copy of the Wood
Destroying Insect Report from the sell, and approval of RP Lee Termite and Pest Control.
This Subterranean Termite Retreatment Guarantee does not prevent and is not intended to control other forms of Termites
mood Formosan_ etc.). Wood Boring Beetles, CaMenter Ants Carpenter Bees Wood Rot Fungus Decay, or any other
woad destroying inseets or orYanisms:
Arbitration: In the event of any dispute arising out of this agreement or any other services performed or not performed the parties
above agree to participate in mediation through and in accordance with the commercial mediation rules of the American Arbitration
Association. The Arbitrator shall consider the legal defenses raised in the arbitration, and the decision of the arbitrator shall be final,
binding, non -appealable and may be entered and enforced in any court having jurisdiction in accordance with the Federal Arbitration
Act
Limitation of Liability Landscaping and grass next to the slab may be damaged during treatment, carpet may need to be pulled
up in certain areas around the home, drill holes may need to be made in floor coverings such as file or linoleum or in cabinets next
to pipe areas, and holes may need to be cut in walls. Customer agrees not to hold RP Lee Termite and Pest Control liable for these
damages, or treatment techniques, or other damages that may occur during treatment
Agreement: This Agreement -shall -be -the -entire agreement between customer and RP LeeTermite and Pest Control.. If any partof
this agreement is found to be invalid it shall not affect the validity of any other part of the Agreement
We are licensed by the Structural Pest Control Board-- 333-Guadalupe Suite 1530
Austin. TX 78701512-305-8g
RP Lee erm � T& Pest Control Cert. Apl.# Customer Sig'dature Date
From:STYLECRAFT BUILDERS INC 979 690 0348 02/27/2008 10:45 #368 P.003/004
SUBTERRANEAN TERMITE PPc-CONSTRUCTION TREATMENT Dt! "LOSURE FOR EACH ESTIMATi
Liceni. nd regulated under the Texas Structural Pest Control
RP LEE TERMITE & PEST CONTROL
PO Box 9423 College Station, TX 77842 • (972) 690-8622 • TPCL #11486
- CUSTOMER INFORMATI N:
Name: J% erg, 0 Phone #1:
Phone #2:
Address: CityShe: Zip Code:
Location to be Treated: .J T fl v E r 7d4/ A LA. 5 7,C 1 %u e5
For all treatments There will be a diagram showing exactly what will be treated prior to the beginning of treatment Review the pesticide label provided to you at this time for minimum treatment standai
Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the law. Review the consumer information sheet for further information. If
have any questions, contact the pest control comoamv or the Texas Structural Pest Control Board, P.O. Box 1927, Austin, TX 78767-1927. Telephone number (512) 305-8250.
Before conducting a termite preconstruction treatment the company will present a complete diagram of the structure inducting construction details. When construction prevents performance of a
treatment, in accordance with a bid for full treatment, any change to a partial treatment by the company providing the treatment will be permitted if the owner of the structure or the person in chargc
the construction and the certified applicator for the pest control company sign a statement attesting to the construction conditions. The agreement must be attached to the contract with an amen(
diagram showing the exact areas to be treated. Copies must be serd to the owner of the property within seven days of the application.
Diagram of Structure(s) and Proposed Area(s) To Be Treated notes:.���e4/1C
W
IMMfe"I
■■■W■0■�■■■■■W
�t�■■■■■■■�■■■[
■■■■■■■■■■■i•■■■■SEEN
v
amal NOW ..�.uric.d.�■■S�■■■■■■■■I•■WESS■S■■■C■■
/ES
SEES■
■W/■■iSS■■S
ESSS
SE E■SE■E
i�■E�■O■■i
■■�
■■■.■■■■.■
■■■■■■■�.■■E�...■E.
E.■■WE■..■s.■■■E..■WE■WE■11W■
■■.SEES
....
.uW.,.
NEE■E■I■W■■
■■■W■■■■�■W
t■
■■■■■■E
■■EEE■■■■
"
WEE
■■■i■.■w■■■CEa■�E�E■.C...■W
.■E.NEW■
MEN
so
�■i■�i ��
■�■■EW■■■iiis����.i��
Aiii��i
�■uu■n■i■�E�i%mo
■■E■■■■E��■■�■E�■i�ii■�■�ii
ri■iii�i�■s■iiii■ii■iinii■■�iE■a
■p
■WOKE■
ENE■■SNEEq■■�■iiHEE■■SSSSWES■�S■SE1■S
�j �
v►,�.---_..i
r�.r/rEEE■■E■■■■q�w■SEEN
�
0W■S■■■■W■■1S■Sia■!■�
■■■■■■■■p■S■■.SSSE■■SWE
i`.
■■W■SE■�■■Eu■N■oSSv;I■■■■SS■
i�Ar
■■i■■■ENEEZEEMIZE
111
E
1■'■■■�11111111■.n>i
smog"
MEN
EEMENE■■iti■EEEE■NEE
m
SEES
■■S■■W■E■■W■ENW■
"■■uE���ii�1■'■i'>v�i'W'i■�'ii■ii■�i■iin■■°'i■"i■i■'O■n
■
im■i
mmE
■iiiaii■�iii�iiii■�iiiiiiiii■i■■u��i■�i■��rr
■p■E�S■�E■p'■'E■u
tl�Wtmlii■■ii■Ei�ii■�iiii■�iii�i�■i■�■�■E■iidE■■m■�
■■■ ■
�■■■SE■SEE■EEO■■E■S■EEESSSE■E)•EE■■■■■■■■■E!■S■■■■■!.■■
■■1■■CSEiS1Wn■/0■
WE■nW■■W■■■u■EEWE■■nu■
Type of treatment proposed: (check all that apply): ❑ Full pi Partial YKNood O Bait ❑ Commercial &tangle Family
Total square feet to be treated: �� . Total linear feet to be treated: ��L. Approximate measurements of structure(s) to be treated:
.A label of termiticide(s) is attached. The percentage of.the termitidde(s) to be applied at this location
Estimated amount of tern itiade to be applied: gallon(s),
THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE IS ATTACHED ON BACK (SPCBID4). THE BOARD -APPROVED SUBTERRANEAN TERMITE
PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUCTION TREATMENT
SERVICE. Complete details of warranty (rf any) inducting time period of warranty, renewal options and cost, and obligations of the contracting parties is attached... If the warranty does not
include the entire structure treated, the areas included in the warranty are (specify):
A consum r information shhea6 also attached.
2l f O z l
Signature of Vor Technician Printed Name Date Signatke of Custoggr Verifying Receipt of This Document Date
nEM 6; U .Wd01WW White Copy -Service Provider Yellow Copy- Cusinmer Fah DesWed end Rita y&-. Cw—imdom tA6b7B2�2/S, 0W., TX02d
s
Service Treatment Invoice
Route: Map Code:
Start Time: tn/pm Finish Time: —am
Type of Servlce:. nitla Regular Follow Up One Time Charity
Service Address
Name: 5�f/�� rtAr
Address: 3TQq -u
City: _ C . S TX �13
Phone:
Date: Z- Z-0�' Appolnt.Time: am/pm
Frequency: BM Q S Y
Structure: I�d Crawl P/B Combo
Pets: Dog(s) Cat(s) Bird(s) Fish A, e_*
Cost of Service
Tax
Total Due
Payment
T — Balance
PEST PROBLEMS: /I,��,�>�•,(,% DIRECTIONS l INSTRUCTIONS:
Billing:
EQUIP. METH. LOCATION(S) PRODUCT
WOOD DESTROYING INSECTS
rr !
Shielding & Protecting
Homes Against Peste ,
TPCL Nii486
QTY
$
Payment by:
$
Cash .❑
$ ""
Check ❑ #.
$ ?r 141.
Credit Card ❑
TARGET PEST(S)
PAYMENT DUE, I.. -.
UPON RECEIPT'.l
TermidorSC-Flproni1.06% Subterranean Termites, Ants Size of Tank Posted
Termitior SOW Fipronll .06% Subterranean Termites. Size of Tank Posted
—�� Bora-care-Dlsodium Octaborate Tetrahydate 50% —Z Subterranean/Formosan/Dryaood Termites, Carpenter Ants, Beetles, Posted. •.'
F1,EAS
MI ROD E NT AT4, MONITORS
OTHER
Invader HPH-Baygon 1%
Demon WP-Cyano-Phenoxypheayl
Dimethycyleyclopropanecarhozylate 1%
Tempo Ultra WP-Cyfluthrin .625% (Rest)
(gen. surface spray, spot, mist, crack & crevice)
Talstar EZ Blfenthrin .2%
Maxforce-Hydramethylon 1%-2.15%
Cykick CS Cyfiuthrin .05%
Phantom S%
Tengard-Permethrin .5%
Suspend SC-Deltaneturin 4.75% (REST)
Nyguord-Methyletnoxy Io% (REST)
Excite R Pyrethtin .05%
Fastrac-Bromethalin .01%
Bait Station-Large/Small Glue Boards
Speckoz-Pyrocide.50%
Bifen 1/T Bifenthrin .06%
Carpenter Ants, Spiders, Crickets, Millipedes, Beetles, Termites.
Cockroaches, Millipedes, Sowbugs, Flles,Tlcks, Mosquitos, Plllbugs,
Silverfish, Bees,Ants, Carpenter Ants, Scorpions, Spiders.
Ants (Except Pharaoh), Cockroaches, Crickets, Earwigs, Millipedes, Flies, Fruit Files, Beetles,
Pfilbugs, Silverfish, Spiders, Gnats, Hornets, Wasps, Yellow Jackets.
Ants, Centipedes, Cockroaches, Crickets, Grasshoppers, Scorpions, Ticks, Silverfish, Spiders.
Pharaoh Ants, Crickets, Carpenter Ants, Lg. Roaches, Variety ofAuts.
Spiders, Scorpions, Ants, Carpenter Ants, Carpenter Bees, Roaches, Crickets, Silverfish.
Pbaroh Ants, Variety of Ants, Roaches.
Pleas,Ticks,Auts, Centipedes, Carpenter Ants, Bees, Wasps, Carpenter Bees, Cockroaches,
Crickets, Files, F.nrtvigs, Millipedes, Beetles, Pillbugs,
Fleas, Bees, Beetles. Roaches, Crickets, Lice, Flies, Scorpions, Ticks, Wasps.
IGR-Growth Regulatol'Fleas, Roaches, Crickets, Flying Insects, Stored Product Pesis.
Fleas.
Mice, Rodents, Rats.
Mice, Rodents, Rate, Bug Monitol•a.
Houseflies, Mosquitos, Moths, Fleas, Wasps, Hornets, Ticks, Cockroaches.
Spiders, Ants, Roaches, Silverfish, Earwigs, Fleas, Scorpions
Eq ment: A -Compressed Sprayer P-Power Sprayer B-Beit Dispenser BS-Bait Station BT-Bait Trap D-Aerosol Can G-Glue Board R-Hand Duster S-Spreader F-Fogger FM-Foamer AC-Actisol unit Other
ations • I -Kitchen 2-Bath(s) 3-&:drooms 4-Dining Room 5-Utility 6-Storage 7-Common Areas &Garage 9-Perimeter of Structure 10-Attic l l-Yard 12-Under Home 13-Warehouse 14.Otitce 15-Exposed Wood 2' up from Slab Other
NMethod of TYeatmentsm CC -Crack & Crevice SS -Sub -Slab Injection VT -Void Treatment BP -Bait Placement BS-Broadcast Spray PB-Perimeter Barrier BV-Brick Venire WT-Wood Treatment
! ' PRECAUTIONS: Do not touch treated areas till dry. Do not tamper with bait stations. Ventilate rooms after treatment. Keep pets away until pesticides have dried.
Licenced b the tructural Pest Control Board - 333 Guadalupe, Suite I-530 • Austin, TX 78701. 512-305-8250 ,
SERVICE TECHNICIAN: d' . CUSTOMER SIGNATURE: P/,l '21° /(f
DATE:
T
0
C/)
n-I
C-D
D
n
00
C
0
M
Cn
z
c-D
CD
v
co
0-)
co
CZ>
CZ)
co
16'
ONC.
o D
IVE
N 48-41'04"
W
TRUC
3
`O/�,N
T♦A
UT
1/2" DIA. SMOOTH DOWEL 2'-0"
LONG W/ PVC CAP - PLACE IN
SLAB OR DRILL 9" INTO EXISTING
1 O'
REAR PUE
6'
a
GRADE BEAM. TAPE CAP TO LEAVE
TOOL EDGE E.J.T.
1" ® END OF ROD
a
0' EARS
TB
-
4" THICK PAVING 3000 PSI
REINF. W/ #3's ®ta o.c.E.w.
BUILD I N G
LINE:
F
NCE W
ONE
CAR
L�
�J • a@
MID DEPTH USE CHAIR SUPPORTS
°
GATE
GARAGE
5
DISCONTINUE REINF. 0 E.J.
1X REDWOOD DIVIDER
CONTRACTION JOINT WHEN
S A��
1
DRIVE < 1 6' WIDE
a
S
4.
m
kbc_ck
°
p 4
4" THICK 3000 PSI CONC.
�
S2�
D
SECTION "ID""
C
°
REINFORCE W/ #3 BARS
N.T.S.
p
18' D.C.E.WW.
N
'o
INSTALL EXPANSION JOINT
p
CONTRACTION JOINT
co
MID -DRIVE IF OVER 45'
o
CONTINUE REINFORCEMENT
°
p�
�.
THROUGH KEYWAY
O 1
Z:, 24'-1 1 Z"
Z
INSTALL METAL KEYWAY
-
oQF///,,RESIDENC
PROPOSE
4" THICK PAVING 3000 PSI
EXP. JOINT W/ 3/8' DIA.
r
om
-�
ONE CHAIR
PER
p
SLICK DWLS. 18" O.C.
o•,i
4 SO. FT.
MIN. REINF. W/ #3's ® 18" O.C.E.W.
°
W/ SLEEVES ONE SIDE
MID DEPTH USE CHAIR. SUPPORTS
PROPERTY LINE
°
C
SECTION "C"
p
20' FO
UE
N.T.S.
Q
RC
SETBA
3907 VICTORIA AVENUE
WESTFIELD VILLAGE
3/8" DIA. DOWEL W/ SLEEVE.
-LOT - 28
DRILL INTO EXISTING SIDEWALK
BLOCK - 8
%ST NG sioEwn�K
�a
4" THICK 3000 PSI CONC.
REINFORCE W/ #3 BARS
a B
35.
0'
PHASE 4
,
(9) 18" O.C.E.W.
N 48°4
'0 "
W
1 X REDWOOD DIVIDER
T,°
°
11.
-
VINYL FENCE
SECTION IIBIN.r.s.
VERIFY TH—
B
SIDEWALK
CITY SIDE WALK
IN FIELD
i
3907
6,
°
Q
3/8- DIA. DOWEL W/ SLEEVE.
p
DRILL INTO EXISTING CURB
O,
B
O
MAIL BOX
/
8" X 8" BEAM
°
W/ 4 #5 REBAR
I
p
°
o
A
SECTION "A"
_
N
N.T.S.
A
'
-r I
LAYDOWN CURB DETAILS '
I
07152
EA
lomm
w U
i
O
cn
MASTER
CREATED:
11/14
PRE -CON:
REVISED:
ISSUED:
PRINTED:
11/14
Lu
t=—
CD
SCALE: -
1 •-za
C-1
WF0983847 / 001 City of College Station
PAGE 1
REQ. DATE: 11/27/07 11/27/07 9:23:14
LOCATION: 3907 VICTORIA AVE LOC ID: 203768
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 11/27/07 SCHED COMPLETION: 11/27/07
********************************************************************************
JOB ORDER RESULT COMMENTS
City of College Station
— 1-9Z TEXAS AVENUE
COLLEGE STATION TX 77840
T E M,P O R A R Y CO
T E M P O R A R Y
Issue Date . . . . . . 2/27/08
Expiration Date . . 3/20/08
Parcel Number . . . . .
Property Address
Subdivision Name
Legal Description . . .
Property Zoning
650730-0408-0280
3907 VICTORIA AVE
COLLEGE STATION TX 77845
WESTFIELD VILLAGE #4, BLOCK 8,
LOT 28
PLANNED DEVL DISTRICT
Owner . . . . . . . . . BCS DEVELOPMENT CO
Contractor . . . . . . STYLECRAFT BUILDERS
979 690-1222
Application number 07-00003396 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . .
Special conditions . .
1. Need proper drainage at front of house.
Approved . . . . . . AV
Building Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
BUILDING PERMIT
CITY OF COLLEGE STATION
110�...TE�AS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00003396 Date 11/26/07
Application pin number . . . 521364
Property Address . . . . . . 3907 VICTORIA AVE
Property ID: 650730-0408-0280
R #: R303410
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL DISTRICT
Application valuation . . . . 98076
Owner Contractor
------------------------ ------------------------
BCS DEVELOPMENT CO STYLECRAFT BUILDERS
4090 SH 6 S 4090 SH 6 S
COLLEGE STATION TX 77845 COLLEGE STATION TX 77845
(979) 690-1222
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE MASONRY
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 1.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1486.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.50
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TRAFFIC IMPACT ANAL (TAZ) 405.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit pin number 536920
Permit Fee 456.00 Plan Check Fee .00
Issue Date . . . . 11/26/07 Valuation . . . . 98076
Expiration Date 5/24/08
Qty Unit Charge Per Extension
BASE FEE 260.00
49.00 4.0000 THOU BLDG, VAL 50001-100000 196.00
----------------------------------------------------------------------------
Special Notes and Comments
-Narrow Wall Bracing Fully Sheathed with 18" Minimum APA
-----Garage Framing -
------------------------------�������----------------
BUILDING DEPT RFP�ESENTATIVE:
/ j 1 71 --, l' e
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00003396
Application pin number . . . 521364
Page 2
Date 11/26/07
Special Notes and Comments
-Garage Ceiling to have 5/8" Type X Ceiling Sheetrock
-Make Sure to have 6'-8" Clearance above Toilet, Under
Stairs
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Includi g One Within 25' Of
Outside A/C Unit
�-
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number 07-00003396
Application pin number . . . 521364
Page 3
Date 11/26/07
Special Notes and Comments
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12".AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR
WORKE ON
Sf
LO TED JIFF
BUILDING DEPT REPRES,F.N%�,TIVE:
—
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Page 4
Application Number . . . . . 07-00003396 Date 11/26/07
Application pin number . . . 521364
Special Notes and Comments
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 200
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC )
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHE FLOOR FROM INSIDE THE
------------------------------------------- ---- `------------
BUILDING DEPT REPRE N'I TIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number . . . . .
07-00003396
Date
11/26/07
Application pin number . . .
521364
----------------------------------------------------------------------------
Special Notes and Comments
ROOM.
ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical)
WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING
ANY WORK
------------------------------------------
Other Fees . . . . . . . . .
---------------------------------
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
---------------------------
Paid Credited
------------------------------
Due
Permit Fee Total 456.00
456.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total 1206.00
1206.00
.00
.00
BUILDING DE
APPLICANT:-
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00003397 Date 11/26/07
Application pin number . . . 603673
Property Address . . . . . . 3907 VICTORIA AVE
Property ID: 650730-0408-0280
R #: R303410
Application type description TEMP POLE
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL DISTRICT
Application valuation . . . . 0
Owner
Contractor
------------------------
BCS DEVELOPMENT CO
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
4090 SH 6 S
COLLEGE STATION
TX 77845
COLLEGE STATION
TX 77845
(979) 690-1222
---------- -----------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit pin number
. 536938
Permit Fee . . .
. 20.00
Issue Date . . .
.-11/26/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
------------------------------
Due
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
------------------------------------------ ---- -------------
BUILDING DEPT EP*�E�TTATTY-F-.
APPLICANT:
For office Use
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
(*/z COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning c5 Developmmt Services
WWW.CSTX.GOV
DATE:
APPLICATION #
TEMP POLE #
ADDRESS/LOCATION: 31n7 VI(,j-0g-IL` Je /
LOT 28 BLOCK VgUBDIVISION 1 FIELD \/tLLAC E `✓5EC/PH � ✓
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTACT PERSON FOR REVIEW COMMENTS: ERIC WIVAGG PHONE: 690-1222 ext. 120
FAX: 690-0348 EMAIL: ewivagg(a)_stylecraft-builders.com
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION ` SLAB ONLY
DUPLEX (Landscape Plans) . REMODEURENOVATION" SWIMMING POOL
TENT/CANOPY
u
DESCRIPTION OF WORK: Conventional Framing
PROPOSED USE: Single Familv Residence
WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPS [j4 ENGINEERED ❑
HOMEOWNER ASSOC IATION/ARC HITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $ qS / 076 V-- TOTAL AREA: 11343 HEATED AREA: /48(-
(Cost of Labor and Materials)
1�/ (� % �X PUBLIC SEWER
1 ❑ SEPTIC/TREATMENT SYSTEM
,Dp OX SEWER TAP: 4"
SIZE
15) �X WATER TAP: %11
SIZE
/01,01:1 OTHER TAP:
SIZE
X TEMP POLE
11' GARAGE TYPE: SINGLE ��
ATTACHED I n J
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial onstru
commercial property, building elevations are required.
Official
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS: 2•
INTERIOR WALL TYPE: Sheet Rock
EXTERIOR WALL TYPE: Siding and/or Masonry
FOUNDATION TYPE: Slab on Grade
ROOF TYPE:
DOUBLE E]
I$TACHED FI
Composition
TRIPLE
CARPORT F1
//
or facade improvements/rdnovations to an existing
Only
�,Ls Plans Examiner Zoning Official
cl"04e' a�Sve -hE let' del°k) Co ments:
ILc ES or NO
- zJ'-, 44o" GA e, 11�r
Fir Marshall
/�oisfu�a, ��irt
Aou/ G�
Im
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
❑ Chemical Termiticide Treatment (Soil Treatment)
%
R13
R30 /
.35
.53 /
R6
13--'
Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& DevelopmentSemicei COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
o - 3�'
DATE:
11 - Z4-07
BUILDING ADDRESS:
.3 0 ' cAnaa Al
I. Foundation Requirements- Minimum City Foundation Standards
NA/gAq
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
U00K
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
K
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
/OK
N)OK
S
CITY OF COLLEGE STATION
Planning d Development Servicef
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
NAtW
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5.. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
AJOK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
CITY OF COLLEGE STATION
Planning d Development Service)
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NA/
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
N6101K
"APPROVED PLANS PER IRC SECTION R106.3.1."
LANS EXAMINER
DATE
REScheck Software Version 3.7.3
Compliance Certificate
Project Title: Plan # 1486A
Report Date: 11/14/07
Data filename: S:\ACADWrchived\Old REScheck\1486_3907 Victoria.rck
Energy Code:
2003 IECC
Location:
College Station, Texas
Construction Type:
Single Family
Glazing Area Percentage:
11%
Heating Degree Days:
1788
Construction Site:
Owner/Agent:
3907 Victoria
College Station , TX 77845
Maximum SHGC: 0.40 Your SHGC: 0.40
Ceiling 1: Flat Ceiling or Scissor Truss:
Ceiling 2: Cathedral Ceiling (no attic):
Wall 1: Wood Frame, 16" o.c.:
Window 1: Metal Frame:Double Pane with Low-E:
SHGC: 0.40
Door 1: Solid:
Door 2: Glass:
SHGC: 0.40
Floor 1: Slab-On-Grade:Heated: , Insulation Depth: 0.0'
Air Conditioner 1: Electric Central Air: 13 SEER
Furnace 1: Forced Hot Air: 80 AFUE
Permit #
Permit Date
Designer/Contractor:
Stylecraft Builders
4090 S. Hwy 6 South
College Station, TX 77845
1414 30.0
0.0
49
72 19.0
0.0
4
1888 13.0
0.0
137
181
0.670
121
20
0.500
10
18
0.580
10
145
0.0
151
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The osed building has been designed to meet the 2003 IECC requirements in
REScheck Version 3.7.3 and to comply with the ma datory is I' etl in the REScheck Inspection Checklist.
S1YLEC2A� 11 / 07
Builder/Designer Company Name Dad