HomeMy WebLinkAboutRES2007-033640?-33(0�{ PREPARED 3/26/09, 8:02:18 INSPECTION TICKET PAGE 2 City of ------------------------------------------------------------------------------------------------ College Station INSPECTOR: BUILDING INSPECTOR DATE 3/25/09 ADDRESS . : 3709 DOVE HOLLOW LN SUBDIV: DOVE CROSSING PH 1C CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER . . PHONE PARCEL . . 230100-1303-0050 APPL NUMBER: 07-00003364 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/22/08 BB- BLDG, FOUNDATION -SLAB TIME: 17:00 4/22/08 AP April 21, 2008 2:47:46 PM glsouth. 04/22/2008 11:30 AM BB PDA Strings up. Slab ground installed B115 03 • 6/20/08 RH BLDG, FRAMING TIME: 17:00 6/20/08 DP June 19, 2008 11:04:00 AM acarter. afternoon Need proper APA nailing pattern at garage. Need draftstopping in all chases. Double up on ceiling joist at +. attic access. Install metal spacer plate for fireplace flue at firestopping on first floor. Will need proper attic ventelation by final. B115 04 7/15/08 BB BLDG, FRAMING TIME: 17:00 7/15/08 AE July 15, 2008 8:30:16 AM acarter. Need proper attic ventilation, by final, as previously noted. B130 01 8/05/08 BB BLDG, INSULATION TIME: 17:00 8/05/08 AE August 5, 2008 8:14:41 AM ccourt. attic insulation inspection. Possibly partial over porch???(per David) Fix duct for upstairs exhaust fan. B125 01 25 9 BLDG, FINAL TIME: 17:00 March 25, 2009 12:27:43 PM kgreen. -------------------------------------- COMMENTS AND NOTES-------------------------------------- Je Igo 14ir 1 8 24 1 a rv..4 70311 03/25/2009 11:40 9797740565 ED,FROEHLING BUILDER PAGE 04/05 i4 F S SPCI3 TERMITE TREATMENT DISCLOSURE DOCUMENT FROEHLING HOMES 3709 DOVE HOLL40W i Full- :t •1■1•p _ • A LABEL FOR ANY OTmER PESTICIDE RECOMMED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMEW. WARRANTY INFORMATION (IF ANY) INCWDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPITONSAND COST THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE. MEAT FOR TERMriE INFESTATIONS OR REPAIR DAMrQE CAUSED SY TtRMITE MFESTAnONB WgHIN THE WARR rY PERIOD, AND THE CONCIMONS THAT :OULO DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY NAG ALSO BEEN ATTACHED, :harges for pre -treat: TOTES: Annual re-newal: d �V�,I J•��1jtlnly � l��i'k .� �� b �'J�1�1�1��pt���'� � 4' � i 1-�'1 hY�p t`n1��, tiJ $218.:86 $116.00 32129 PT CA or T*Wnd- SPCH Uoonae 4 41211200E 32129 PT 03/25/2009 11:40 9797740565 ED FROEHLING BUILDER PAGE 05/05 ACE PEST CONTROL T.P.C.L; # 7120 PT PO BOX 4474 MY^ TX 77805 (979) 823-7777 (979) 7744736 CFRL'IFICATE The foIlowi>ug property. 3709 DOVE 1EIOLLOW built by FROEHLING H. OMES _.- State of Texas County of BRAZOS the city of COLLEGE STATION Mailing Address SAME Zip code 77845 was treated for subterranean termites on this day APRIL 21 2008 and has met with approval. Cost of initial treatment, $2,M86, is payable upon completion of work. The treatment is guaranteed for 12 months from the date of treatment. Thereafter, this contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection and renewal fee of 115 lus tax, for a period of wears. (see attached letter) If at any time during this contract a reinfestation of, subterranean termites should occur, the above said property .will be treated at no additional cost to the owner. ACE PEST CONTROL does not accept any liability for any subterranean termite damage repair. Failure to pay the annual renewal fee within thirty days after the inspection date shall be construed as a cancellation of this contract. Any alteration or addition to the foundation of the above described property without proper termite treatment by ACE PEST CONTROL Services shall nullify this contract. Licensed and Regulated by the 'texas Department of Agriculturo, Structural nest Control service, PO Box 12847, Austin, Texas 78711-2847 (512)305-8250 WF0985118 / 001 City of College Station PAGE 1 REQ. DATE: 12/03/07 12/03/07 8:58:53 LOCATION: 3709 DOVE HOLLOW LN LOC ID: 205488 REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" SWR 4" * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/03/07 SCHED COMPLETION: 12/03/07 ******************************************************************************** JOB ORDER RESULT COMMENTS BU;LD,ING PERMIT CITY OF COLLEGE -STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 07-00003364 Date 11/30/07 Application pin number . . . 857352 Property Address . . . . . . 3709 DOVE HOLLOW LN Property ID: 230100-0103-0050 R #: R Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 153846 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMLY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2331.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 538173 Permit Fee . . . . 622.00 Plan Check Fee .00 Issue Date . . . . 11/30/07 Valuation . . . . 153846 Expiration Date . . 5/28/08 Qty Unit Charge Per Extension BASE FEE 460.00 54.00 3.0000 THOU BLDG, VAL 100001-500000 162.00 ---------------------------------------------------------------------------- Special Notes and Comments -Narrow Wall Bracing Fully Sheathed with 16" Minimum APA Garage Framing -------------------- BUILDING DEPT REPRESENTATIVE: ------------ APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00003364 Application pin number . . . 857352 Page 2 Date .11/30/07 Special Notes and Comments -Need to add ist level smoke detector -Garage Ceiling 5/8" Type X sheetrock -2nd floor operable windows must be minimum 24" AFF ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. Garage ceiling must have 5/8" Type X sheetrock when there is Habitable space above the garage. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOPJPE AND EADE - BUILDING DEPT REPRESENTATIVE: APPLI BUI,LDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00003364 Date 11/30/07 Application pin number . . . 857352 ---------------------------------------------------------------------------- Special Notes and Comments PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glaz ng area that --------------------------------------------------�----------- BUILDING DEP EPRES NTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 07-00003364 Date 11/30/07 Application pin number . . . 857352 ---------------------------------------------------------------------------- Special Notes and Comments exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 200-. A .40 OR LOWER FACTOR AND ABOVE 20% TO 3001 A .35 FACTO OR LOWER SHALL BE MET. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRW - --AY WITHIN 36" AND -----------------------------------------------�- ----------------- BUILDING DEPT RENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 07-00003364 Date 11/30/07 Application pin number . . . 857352 ---------------------------------------------------------------------------- Special Notes and Comments LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC ) RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE ROOM. ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ---------------------------------------- Due ----------------- Permit Fee Total 622.00 622.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1372.00 1372.00 .00 .00 ------------------------------------------✓ ----- BUILDING DEPT -RXAFIR�NTATIVE: APPLI APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION COL EGE S AT ON, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Pl ming&Do-1g 1&nim tIWVW.CSTX.GOV ADDRESS/LOCATION: LOT _ff BLOCK SUBDIVISION BUSINESS/OWNER NAME: DATE: APPLICATION A TEMP POLE A V SEC/PHt_C, PHONE: CONTRACTOR/HOMEOWNER: G b �ROEOLU-ka t5UILPHONE: —%T(O —&Z&(P CONTACT PERSON FOR REVIEW COMMENTS: 1 `lkA(- PHONE: 714-06UP5 FAX: 7r�• ELECTRICIAN: eg M Gam, IC. HVAC: %.)G %tjW0VAT1Vrc EMAIL: PLUMBER: GOOD CENTS (Residential only): ACCESSORY/STORAGE OVING RE -ROOF r� ADDITION NEW CONSTRUCTION" SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION REMODEL/RENOVATION" DESCRIPTION OF WORK: PROPOSED USE: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD S) PROJECT REGISTRATION# EABPRJ VALUATION: $ (ltI0515 TOTAL AREA:Z�3I HEATED AREA: 273 -31 (Cost of Labor and Materials) MOOP'UBLIC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: 4It SaE �IVATER TAP: �i �I14 s• SME OTHER TAP: ❑ TEMP POLE GARAGE TYPE: SME SINGLE ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE EZf TRIPLE DETACHED SIGNATURE OF APPLICANT��—������ "If proposed work involves new commercial construction or facade improvements/renovations to an existing commercial property, building elevations are required. Offlctal Use Only Plans Examiner L S4rMYL s X Cet'I i'� Sliz Vining Official -Nu.� /eZeVeA Comments: O or NO s ,k. �� ✓�vli� Ib`'V►^CW. Energy Code Compliance Information Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling.I (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating Protection Against Subterranean Termites Chemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) y' ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. r tti 1 s 1' � 4 ,.4 Z LVP� q 71C n? erg:'�urveyIng, n L01 05lD.i k SB f , '• f lffaao qiL ,stir fill• Tier aTldKf�/Ai dO ,l �a oy sock 3Awg � • common Mee �• Now qr Form" PM —Tan Inveelr„gntb j Vol, 7476, ?y. am i n 20'[ .U.E S 4OIM"JY' £ — 5500' I Not. WIldrrp Utbock Line. per I City o1 Caveat Gwen Uatkd ba+looRIMN OrdGianco #W 7 I ' r I i I t 2" r 20' Lot 4 I No* or Ferree ... .. Lot 8 Ed Frbom Mro 39.3• 7,%' No ' ar F Voarrrpflr l 70J � Ed Fro �hFr,gg Bulld.r, 'Y� I I Vof. Tags. Pig. 1B4Irc N J700 Dom fplO�iid�N LamLot A • � �+ b Q 2 � try • I Res**" a I I i I I b! D I r i $ f PAL Dove Hollow Loner 50' AO-W.. — 27' Pavemtnt PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# D _ DATE: BUILDING ADDRESS: bo ve (�ow I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated NOK II. Framing: Floor, Wall, Ceiling and Roof Requirements A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. San exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. 1"/OK OK PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning dDevelopment Semicct COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details NA/ 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NA/ 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location CITY OF COLLEGE STATION Planning d Development Service! PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N K B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/ K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NA/ Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 N / Does not block any water course or divert any flow Elevation certificate needed WK� "APPROVED PLANS PER IRC SECTION R106.3.1." PLANS EXAMINER DATE Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC RES check Software Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\3709DH.rck TITLE: 3709 DOVE HOLLOW LANE CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 10/25/07 DATE OF PLANS: 10/24/07 PROJECT INFORMATION: LOT 5 BLOCK 3 DOVE CROSSING I COMPANY INFORMATION: ED FROEHLING BUILDER, INC. NOTES: 39.5 MOD. RABON COMPLIANCE: Passes Maximum UA = 811 Your Home UA = 585 27.9% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.39 Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 1319 30.0 0.0 46 Wall 1: Wood Frame, 16" o.c. 632 13.0 0.0 40 Window 1: Metal Frame:Double Pane with Low-E 110 0.640 70 SHGC: 0.40 Bldg. faces 225 deg. from North; Comp. orient.: Front Projection factor: 0.13 Door 1: Solid 38 0.400 15 Wall 2: Wood Frame, 16" o.c. 640 13.0 0.0 48 Window 2: Metal Frame:Double Pane with Low-E 50 0.640 32 SHGC: 0.40 Bldg. faces 225 deg. from North; Comp. orient.: Left Side Projection factor: 0.13 Wall 3: Wood Frame, 16" o.c. 632 13.0 0.0 45 Window 3: Metal Frame:Double Pane with Low-E 68 0.640 44 SHGC: 0.40 Bldg. faces 225 deg. from North; Comp. orient.: Back Projection factor: 0.13 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 225 deg. from North; Comp. orient.: Back Projection factor: 0.13 Wall 4: Wood Frame, 16" o.c. 640 13.0 0.0 50 Window 4: Metal Frame:Double Pane with Low-E 29 0.640 19 SHGC: 0.40 Bldg. faces 225 deg. from North; Comp. orient.: Right Side Projection factor: 0.13 Floor 1: Slab -On -Grade: Unheated 159 0.0 166 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 13 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly MECchec/ and to comply with the mandatory requirements listed in the REScheck Inspection Check Builder/Design_.,, ate 10o