INSPECTION TICKET PAGE
2
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR DATE
3/25/09
ADDRESS
. : 3709 DOVE HOLLOW LN SUBDIV: DOVE CROSSING PH 1C
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER
. .
PHONE
PARCEL
. . 230100-1303-0050
APPL NUMBER: 07-00003364 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
4/22/08
BB-
BLDG, FOUNDATION -SLAB TIME: 17:00
4/22/08
AP
April 21, 2008 2:47:46 PM glsouth.
04/22/2008 11:30 AM BB PDA
Strings up. Slab ground installed
B115 03
• 6/20/08
RH
BLDG, FRAMING TIME: 17:00
6/20/08
DP
June 19, 2008 11:04:00 AM acarter.
afternoon
Need proper APA nailing pattern at garage. Need
draftstopping in all chases. Double up on ceiling joist
at
+.
attic access. Install metal spacer plate for fireplace
flue
at firestopping on first floor. Will need proper attic
ventelation by final.
B115 04
7/15/08
BB
BLDG, FRAMING TIME: 17:00
7/15/08
AE
July 15, 2008 8:30:16 AM acarter.
Need proper attic ventilation, by final, as previously
noted.
B130 01
8/05/08
BB
BLDG, INSULATION TIME: 17:00
8/05/08
AE
August 5, 2008 8:14:41 AM ccourt.
attic insulation inspection. Possibly partial over
porch???(per David)
Fix duct for upstairs exhaust fan.
B125 01
25 9
BLDG, FINAL TIME: 17:00
March 25, 2009 12:27:43 PM kgreen.
-------------------------------------- COMMENTS AND NOTES--------------------------------------
Je Igo 14ir 1 8 24 1 a rv..4
70311
03/25/2009 11:40 9797740565 ED,FROEHLING BUILDER PAGE 04/05
i4
F
S SPCI3 TERMITE TREATMENT DISCLOSURE DOCUMENT
FROEHLING HOMES
3709 DOVE HOLL40W
i
Full-
:t
•1■1•p _ •
A LABEL FOR ANY OTmER PESTICIDE RECOMMED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMEW. WARRANTY INFORMATION (IF ANY)
INCWDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPITONSAND COST THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE.
MEAT FOR TERMriE INFESTATIONS OR REPAIR DAMrQE CAUSED SY TtRMITE MFESTAnONB WgHIN THE WARR rY PERIOD, AND THE CONCIMONS THAT
:OULO DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY NAG ALSO BEEN ATTACHED,
:harges for pre -treat:
TOTES: Annual re-newal:
d �V�,I J•��1jtlnly � l��i'k .� �� b �'J�1�1�1��pt���'� � 4' � i 1-�'1 hY�p t`n1��, tiJ
$218.:86
$116.00
32129 PT
CA or T*Wnd- SPCH Uoonae 4
41211200E
32129 PT
03/25/2009 11:40 9797740565 ED FROEHLING BUILDER PAGE 05/05
ACE PEST CONTROL
T.P.C.L; # 7120 PT
PO BOX 4474
MY^ TX 77805
(979) 823-7777
(979) 7744736
CFRL'IFICATE
The foIlowi>ug property. 3709 DOVE 1EIOLLOW
built by FROEHLING H. OMES _.- State of Texas
County of BRAZOS the city of COLLEGE STATION
Mailing Address SAME Zip code 77845
was treated for subterranean termites on this day APRIL 21 2008 and has met with
approval. Cost of initial treatment, $2,M86, is payable upon completion of work. The
treatment is guaranteed for 12 months from the date of treatment. Thereafter, this
contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection
and renewal fee of 115 lus tax, for a period of wears. (see attached letter) If
at any time during this contract a reinfestation of, subterranean termites should occur, the
above said property .will be treated at no additional cost to the owner. ACE PEST
CONTROL does not accept any liability for any subterranean termite damage repair.
Failure to pay the annual renewal fee within thirty days after the inspection date shall be
construed as a cancellation of this contract. Any alteration or addition to the foundation
of the above described property without proper termite treatment by ACE PEST
CONTROL Services shall nullify this contract.
Licensed and Regulated by the
'texas Department of Agriculturo,
Structural nest Control service,
PO Box 12847, Austin, Texas 78711-2847
(512)305-8250
WF0985118 / 001 City of College Station
PAGE 1
REQ. DATE: 12/03/07 12/03/07 8:58:53
LOCATION: 3709 DOVE HOLLOW LN LOC ID: 205488
REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 12/03/07 SCHED COMPLETION: 12/03/07
********************************************************************************
JOB ORDER RESULT COMMENTS
BU;LD,ING PERMIT
CITY OF COLLEGE -STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00003364 Date 11/30/07
Application pin number . . . 857352
Property Address . . . . . . 3709 DOVE HOLLOW LN
Property ID: 230100-0103-0050
R #: R
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 153846
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME RD
COLLEGE STATION
TX 77845
(979) 776-8266
--- Structure Information
000 000 SINGLE FAMLY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
N/A
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2331.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.50
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TRAFFIC IMPACT ANAL (TAZ)
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
AC
Permit pin number .
538173
Permit Fee . . . .
622.00 Plan Check Fee
.00
Issue Date . . . .
11/30/07 Valuation . .
. . 153846
Expiration Date . .
5/28/08
Qty Unit Charge
Per
Extension
BASE FEE
460.00
54.00 3.0000
THOU BLDG, VAL 100001-500000
162.00
----------------------------------------------------------------------------
Special Notes and Comments
-Narrow Wall Bracing
Fully Sheathed with 16" Minimum
APA
Garage Framing
--------------------
BUILDING DEPT REPRESENTATIVE:
------------
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00003364
Application pin number . . . 857352
Page 2
Date .11/30/07
Special Notes and Comments
-Need to add ist level smoke detector
-Garage Ceiling 5/8" Type X sheetrock
-2nd floor operable windows must be minimum 24" AFF
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOPJPE AND EADE -
BUILDING DEPT REPRESENTATIVE:
APPLI
BUI,LDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 07-00003364 Date 11/30/07
Application pin number . . . 857352
----------------------------------------------------------------------------
Special Notes and Comments
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glaz ng area that
--------------------------------------------------�-----------
BUILDING DEP EPRES NTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 07-00003364 Date 11/30/07
Application pin number . . . 857352
----------------------------------------------------------------------------
Special Notes and Comments
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 200-. A .40 OR LOWER FACTOR AND ABOVE 20%
TO 3001 A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRW
- --AY WITHIN 36" AND
-----------------------------------------------�- -----------------
BUILDING DEPT RENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number . . . . . 07-00003364 Date
11/30/07
Application pin number . . . 857352
----------------------------------------------------------------------------
Special Notes and Comments
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC )
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE
ROOM.
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited
----------------------------------------
Due
-----------------
Permit Fee Total 622.00 622.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1372.00 1372.00 .00
.00
------------------------------------------✓ -----
BUILDING DEPT -RXAFIR�NTATIVE:
APPLI
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
COL EGE S AT ON, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Pl ming&Do-1g 1&nim tIWVW.CSTX.GOV
ADDRESS/LOCATION:
LOT _ff BLOCK SUBDIVISION
BUSINESS/OWNER NAME:
DATE:
APPLICATION A
TEMP POLE A
V
SEC/PHt_C,
PHONE:
CONTRACTOR/HOMEOWNER: G b �ROEOLU-ka t5UILPHONE: —%T(O —&Z&(P
CONTACT PERSON FOR REVIEW COMMENTS: 1 `lkA(- PHONE: 714-06UP5
FAX: 7r�•
ELECTRICIAN: eg M Gam, IC.
HVAC: %.)G %tjW0VAT1Vrc
EMAIL:
PLUMBER:
GOOD CENTS (Residential only):
ACCESSORY/STORAGE OVING RE -ROOF r�
ADDITION NEW CONSTRUCTION" SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODEL/RENOVATION"
DESCRIPTION OF WORK:
PROPOSED USE:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD S) PROJECT REGISTRATION# EABPRJ
VALUATION: $ (ltI0515 TOTAL AREA:Z�3I HEATED AREA: 273
-31
(Cost of Labor and Materials)
MOOP'UBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP:
4It
SaE
�IVATER TAP: �i �I14 s•
SME
OTHER TAP:
❑ TEMP POLE
GARAGE TYPE:
SME
SINGLE
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE EZf TRIPLE
DETACHED
SIGNATURE OF APPLICANT��—������
"If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Offlctal Use Only
Plans Examiner
L S4rMYL s
X Cet'I i'� Sliz
Vining Official
-Nu.� /eZeVeA
Comments:
O or NO
s ,k. ��
✓�vli�
Ib`'V►^CW.
Energy Code Compliance Information
Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling.I (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
y' ❑ Physical Barriers
❑ Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
r
tti
1
s
1'
�
4
,.4 Z LVP� q 71C n? erg:'�urveyIng, n
L01 05lD.i k SB f , '• f lffaao qiL ,stir fill• Tier aTldKf�/Ai dO ,l
�a oy sock 3Awg � •
common Mee
�• Now qr Form"
PM —Tan Inveelr„gntb
j Vol, 7476, ?y. am
i
n
20'[ .U.E S 4OIM"JY' £ — 5500'
I Not. WIldrrp Utbock Line. per
I City o1 Caveat Gwen Uatkd
ba+looRIMN OrdGianco #W 7 I '
r I i I t
2" r 20'
Lot 4
I
No* or Ferree ... .. Lot 8
Ed Frbom Mro 39.3• 7,%' No ' ar F
Voarrrpflr
l 70J � Ed Fro �hFr,gg Bulld.r,
'Y� I I Vof. Tags. Pig. 1B4Irc
N J700 Dom fplO�iid�N LamLot A • �
�+ b Q
2 � try •
I Res**" a I
I i
I I
b! D I r i
$ f PAL
Dove Hollow Loner
50' AO-W.. — 27' Pavemtnt
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# D _
DATE:
BUILDING ADDRESS: bo ve (�ow
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
NOK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
San exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
1"/OK
OK
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning dDevelopment Semicct COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
NA/
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
CITY OF COLLEGE STATION
Planning d Development Service!
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/ K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
N /
Does not block any water course or divert any flow
Elevation certificate needed
WK�
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER
DATE
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
RES check Software Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\3709DH.rck
TITLE: 3709 DOVE HOLLOW LANE
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 10/25/07
DATE OF PLANS: 10/24/07
PROJECT INFORMATION:
LOT 5 BLOCK 3
DOVE CROSSING I
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC.
NOTES:
39.5 MOD. RABON
COMPLIANCE: Passes
Maximum UA = 811
Your Home UA = 585
27.9% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.39
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
1319
30.0
0.0
46
Wall 1: Wood Frame, 16" o.c.
632
13.0
0.0
40
Window 1: Metal Frame:Double Pane with Low-E
110
0.640
70
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Front
Projection factor: 0.13
Door 1: Solid
38
0.400
15
Wall 2: Wood Frame, 16" o.c.
640
13.0
0.0
48
Window 2: Metal Frame:Double Pane with Low-E
50
0.640
32
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Left Side
Projection factor: 0.13
Wall 3: Wood Frame, 16" o.c.
632
13.0
0.0
45
Window 3: Metal Frame:Double Pane with Low-E
68
0.640
44
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Back
Projection factor: 0.13
Door 2: Glass 18 0.580 10
SHGC: 0.78
Bldg. faces 225 deg. from North; Comp. orient.: Back
Projection factor: 0.13
Wall 4: Wood Frame, 16" o.c. 640 13.0 0.0 50
Window 4: Metal Frame:Double Pane with Low-E 29 0.640 19
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Right Side
Projection factor: 0.13
Floor 1: Slab -On -Grade: Unheated 159 0.0 166
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchec/ and to comply with the mandatory requirements listed in
the REScheck Inspection Check
Builder/Design_.,, ate 10o