HomeMy WebLinkAboutRES2007-03350, 07-3351O'!•335G
Cr7sp 3351
13
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . . .
Application number
Description of Work
Construction type .
Occupancy type . . . .
Flood Zone . . . . . .
Approved . . . . . . .
3/06/08
184100-0170-0240
4232 ROCKY RHODES DR
COLLEGE STATION TX 77845
CASTLE ROCK PH lA
CASTLEROCK PH lA
BLK 7 LOT 24
PLANNED DEVL DISTRICT
BENCHMARK - DBA G D T INC
979 690-7117
07-00003350 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
�l /"I
uiultiner Urticia
VOID UNLESS SIGNED BY BUILDING OFFICIAL
(1/4/2008) Kim Wolfe - Insulation request inspection result, 4232 Rocky Rhodes, #07-3350 Page 1
From: Brian Henry
To: Southerland, Gina
Date: 1/4/2008 8:52 AM
Subject: Insulation request inspection result,
CC: Carter, Amber; Wolfe, Kim
Print for file
4232 Rocky Rhodes; #07-335071
Inspected Insulation, 4232 Rocky Rhodes, #07-3350, Benchmark Homes, 12-28-07
Inspection result: Inspected OK for Good Cents
PREPARED 3/04/08, 7:45:35 INSPECTION TICKET PAGE 9
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/03/08
------------------------------------------------------------------------------------------------
ADDRESS . : 4232 ROCKY RHODES DR SUBDIV: CASTLE ROCK PH lA
CONTRACTOR :.BENCHMARK - DBA G D T INC PHONE (979) 690-7117
OWNER . . . PHONE
PARCEL . . : 184100-0170-0240
APPL NUMBER: 07-00003350 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
.\B100 O1 12/03/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00
\ 12/03/07 AP December 3, 2007 11:05:13 AM glsouth.
12/03/2007 02:36 PM RH PDA
Strings up, slab ground installed.
B115 01 12/21/07 OC BLDG, FRAMING TIME: 17:00
12/26/07 AE December 14, 2007 2:28:27 PM kwolfe.
friday afternoon
12/26/2007 11:47 AM OC PDA
need to check garage returns at insulting insp.
B115 02 12/27/07 OC BLDG, FRAMING TIME: 17:00
12/28/07 AP December 27, 2007 3:58:57 PM kwolfe.
since we will not be doing inslation inspection (good cents
home) he wanted us to come back out........:-)
B130 01 1/04/08 BH BLDG, INSULATION TIME: 17:00
1/04/08 AP January 4, 2008 9:10:02 AM kwolfe.
January 4, 2008 9:10:27 AM kwolfe.
B125 01 3/03/08 BLDG, FINAL TIME: 17:00
3 j-69 J2 March 3, 2008 3:51:59 PM kwolfe.
-------------------------------------- COMMENTS AND NOTES -----------------------------------
`t
Date: 3/4/2008
Inspection Comments for Final,
Permit Year: 7 permit Number: 335(
Address: 4232 ROCKY RHODES DR
Type
inspection Type Code
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION-SLj
IC
12/03/2007 02:36 PM RH PDA
B100
BLDG, FOUNDATION-SU
IC
Strings up, slab ground installed.
B115
BLDG, FRAMING
IC
12/26/2007 11:47 AM OC PDA
B115
BLDG, FRAMING
IC
need to check garage returns at insulting insp.
B130
BLDG, INSULATION
IC
January 4, 2008 9:10:27 AM kwolfe.
E110
ELEC, ROUGH IN
IC
12/20/2007 02:42 PM RH PDA
Ell
ELEC, ROUGH IN
IC
Connect bond wire at gas.
Page 1
Mar 06 08 12:12p
MAC IAS
.1
9797744736 p.1
Ace Pest Control
T.P.C.L.# 7120 PT
PO BOX 4474
BRYAN TX, 77805
(979) 923-7777 office
(979) 774-4736 fax
Fax Cover Sheet
CC
To: «J. number of pages including cover page
Phone:
Fax: MA ` 34Q t,�-
From: ACE PEST CONTROL
Date:
Thanks
1)1�Lz -3-
Ace Pest Control
Mar 06 08 12:12p MACIAS 9797744736 p.2
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
. - .iy Ownerm . BENCHMARK HOMES
Perce1 r_ ge of r-11 • • • e • a•at this • •.1. I f.
A LABEL FOR ANY OTKR PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF TKS DOMIENT. WARRANTYINFORMATIDN(IFANn
INCLUDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE.
TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED By TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITION THAT
COULD DEVELOP ASA RESULTOF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED.
Charges for pre -treat
NOTES: Annual re -newel:
SEE ATTACHED SKETCH
BUILDERS SUPPLIES SKETCHI PLAN
$326.42
$126.00
32129 PT 12/3/2007
Ca ar TecMacI4m aPCB IIcansa N 32M AT
WF0983950 / 001. City of College Station PAGE 1
REQ. DATE: 11/27/07 11/27/07 12:28:11
LOCATION: 4232 ROCKY RHODES DR LOC ID:. 209662
REQUESTOR: BENCHMARK HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 11/27/07 SCHED COMPLETION: 11/27/07
********************************************************************************
JOB ORDER RESULT COMMENTS
BUILDING PERMIT
CITY OF COLLEGEi STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00003350 Date 11/27/07
Application pin number . . . 154100
Property Address . . . . . . 4232 ROCKY RHODES DR
Property ID: 184100-0170-0240
R #:
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . CASTLE ROCK PH lA
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL DISTRICT
Application valuation . . . . 118206
Owner
Contractor
------------------------
------------------------
BENCHMARK - DBA G
D T INC
1110 12TH MAN CIR
COLLEGE STATION
TX 77845
(979) 690-7117
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
DUE
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1791.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TRAFFIC IMPACT ANAL (TAZ)
441.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
AC
Permit pin number
537266
Permit Fee
517.00 Plan Check Fee
.00
Issue Date . . . .
11/27/07 Valuation . . .
. 118206
Expiration Date . .
5/25/08
Qty Unit Charge
Per
Extension
BASE FEE
460.00
19.00 3.0000
THOU BLDG, VAL 100001-500000
57.00
----------------------------------------------------------------------------
Special Notes and Comments
-Narrow Wall Bracing
Fully Sheathed with 18" Minimum APA
Garage Framing and Interior Anchors an Bracing to the
Right
---------------------------------------- =--- ----- - -- -
BUILDING DEPT-.QaEPREfNTATTIV.&,
-------------
APPLICANT':
BUILDING PERMIT
CITY OF COLLEGE. STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00003350
Application pin number . . . 154100
Page 2
Date 11/27/07
Special Notes and Comments
of Front Door area.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations,
Outside A/C Unit
Including One Within 25' Of
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
BUILDING
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE,STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 07-00003350 Date 11/27/07
Application pin number . . . 154100
----------------------------------------------------------------------------
Special Notes and Comments
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
------------------------------------ - - - - -- %-----1�/' --- 4- -f----- - - - - - -
BUILDING DEP-T-&REPRESENTATIVE
APPLI
BUILDING PERMIT
CITY OF COLLEGE.STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 07-00003350 Date 11/27/07
Application pin number . . . 154100
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 2001 A .40 OR LOWER FACTOR AND ABOVE 200
TO 3001 A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TA 3/4" 400.00
------------------------------------------- -- � --- -- -------------
BUILDING DEPT ZEPRES
APPLI
BUILDING PERMIT
CITY OF COL,LEGE.STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 5
Application Number . . . . .
07-00003350
Date 11/27/07
Application pin number . . .
154100
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid
----------
Credited
----------
Due
----------
-----------------
Permit Fee Total 517.00
517.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total 1267.00
1267.00
.00
.00
BUILDING
APPLICANT
TEMPORARY POLE PERMIT
CITY OF COLLEGE.STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00003351 Date 11/27/07
Application pin number . . . 254146
Property Address . . . . . . 4232 ROCKY RHODES DR
Property ID: 184100-0170-0240
R #.
Application type description TEMP POLE
Subdivision Name . . . . . . CASTLE ROCK PH lA
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL DISTRICT
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
BENCHMARK - DBA G D
T INC
1110 12TH MAN CIR
COLLEGE STATION
TX 77845
(979) 690-7117
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. AC
Permit pin number
. 537274
Permit Fee . . .
. 20.00
Issue Date . . .
. 11/27/07
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
------------------------------
Due
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT REPRES INTATWEN - G
APPLICANT:
r
- - - - - 1 ------------
/ ForOfficeUse Only
APPLICATION FOR BUILDING PERMIT DATE: -l"l'V� TRCCREG 01M4\
CITY OF COLLEGE STATION � , J� D
1101 TEXAS AVENUE APPLICATION # �J
COLLEGE STATION, TX 77840 TEMP POLE
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning d Development Snvien
WWIN.GSTX.GOV /
ADDRESS/LOCATION: s/
LOT Oq' / BLOCK 77 SUBDIVISION �iAS`�IZ KOGI�C '/ SEC/PH��I'///
BUSINESS/OWNER NAME: e:DT :TAr. PHONE: 79 -1-90 7/I
CONTRACTOR/HOMEOWNER: 5�.16AA-A*l 0 7 PHONE: L 7'7°'
CONTRACTOR ADDRESS: 11 In I -4(A Ak&,1 -Cy -2
ELECTRICIAN: c/kC de % C PLUMBER: `7, ii S .�A. ; e-
d w c
HVAC: % is �Z , 2 GOOD CENTS (Residential only): S
CLASS OF WORK
'n ACCESSORY/STORAGE LOCATION. RE -ROOF
1 ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL
�`►. Required)
DESCRIPTION OF WORK: ►�� �° �� S �;N� c�=mac»-.�.� �� ryc � �
kk
.STRUCTURE USE:
HOMEOWNER ASSOC IATIO N/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
( TEXAS ACCESSIBILITY STANDARD (TA(S) PROJECT REGISTRATION# BPRJ
VALUATION: $ I b} Z�.Cp ✓TOTAL AR HEATED AREA: `1
(Cost of Labor and Materials)--
PUBLIC SEWER Nl OMS:
.❑ SEPT'Ic TREATMENT SYSTEM
SEWER TAP: f 1
SIZE
WATER TAP: � ) f
SIZE
OTHER TAP:
SIZE
}� TEMP POLE
ROOF TYPE:
5 (AL Iry
(26IL& p6)s;
GARAGE TYPE: SINGLE a DOUBLE ® TRIPLE E
ATTACHED DETACHEDRPORT a
SIGNATURE OF APPLICANT:
*If proposed work involves new coni , construction orfacade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
C mments:
U�orNO
/r/l4 Plans Examiner ✓ Zoning Official
—✓ �r�rz�. ye W 11-� �v (�t( s� w� �y'c�tt,,'N G
�i4cv�,� �4cct'is s-1-v�cM`� g�bu�3 � A,�i�o►�-s �"° /� off' ��' >�'� �,,
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls)
Insulation R value of ceiling 1 (flat areas) 3
Insulation R value of. ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating ��
{
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
,
Insulation R value of ceiling 1 (flat areas)
I
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
a
R value of ductwork
r
A/C SEER Rating
Protection Against Subterranean Termites
I
Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
I
❑ Other
I
I
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
w PLAN REVIEW
Vt*t/4"ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
. CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 017 _ 3 3 Sv 7
DATE: / f _ I �! 0-7
BUILDING ADDRESS:
C_km rL kaU e-
I. Foundation Requirements- Minimum City Foundation Standafds
NlAtbho
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
K
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
San exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
&WOK
OK
CITY OF COLLEGE STATION
Planning d' Development Servitef
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
WOK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
CITY OF COLLEGE STATION
Planning 6- Development Servial
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N AJ#K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N K
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N K
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER
0-7
DATE
/c
REScheck Software Version 4.0.1
Compliance Certificate
Project Title: Benchmark Homes Job 300
Report Date: 11/13/07
Data filename: C:\Program Files\Check\REScheck\REScheck docs\300BM.rck
Energy Code: 2003 IECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 13%
Heating Degree Days: 1788
Construction Site: Owner/Agent:
4232 Rocky Rhodes Drive
College Station, TX 77845
Permit Date: November 14, 2007
Designer/Contractor:
Compliance: Passes Maxim m UA: 7■18 Your Home UA: 57�1 > 20.5% Better Than Code (UA)
Maximum SHGC: •0 Your SHGC: 0.34
Ceiling 1: Flat Ceiling or Scissor Truss:
1791 30.0
0.0 63
Wall 1: Wood Frame, 16" o.c.:
1926 13.0
3.4 116
Window 1: Metal Frame:Double Pane with Low-E:
229
0.650 149
SHGC: 0.34
Door 1: Solid:
21
0.400 8
Door 2: Glass:
21
0.650 14
SHGC: 0.34
Floor 1: Slab -On -Grade: Unheated:
212
0.0 221
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air: 14 SEER
Furnace 1: Forced Hot Air: 80 AFUE
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Version 4.0.1 and to comply with the mandatory requirem s listed n the RE ch Inspection Checklist.
4 /v (7
Name - Title Sign ture Date
Project Notes:
First Time to Build this plan. (Four Bedroom two bath. (1791 Heated)
BENCHMARK HOMES Job 300
4232 ROCKY RHODES DR.
College Station, Texas 77845
BENCHMARK HOMES
1110 12th Man Court
College station, Texas 77845
PLAN 1791 S/Ft.
Benchmark Homes Job 300 Page 1 of 4
REScheck Software Version 4.0.1
Inspection Checklist
Date: 11 /13/07
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.4 continuous insulation
Comments:
Windows:
❑ Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.650
For windows without labeled U-factors, describe features:
Wanes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1: Solid, U-factor: 0.400
Comments:
❑ Door 2: Glass, U-factor: 0.650
Comments:
Floors:
❑ Floor 1: Slab -On -Grade: Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
❑ Air Conditioner 1: Electric Central Air: 14 SEER or higher
Make and Model Number:
❑ Furnace 1: Forced Hot Air. 80 AFUE or higher
Make and Model Number:
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values are determined in
accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, fixtures are installed with a 3" clearance from insulation.
Skylights:
❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13.
Materials Identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
Benchmark Homes Job 300
Page 2 of 4
❑ Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency are clearly marked on the building plans or
specifications.
Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a
manner that achieves the rated R-value without compressing the insulation.
Duct Insulation:
❑ Supply ducts in unconditioned attics or outside the building are insulated to R-8.
o Return ducts in unconditioned attics or outside the building are insulated to R-4.
Cj Supply ducts in unconditioned spaces are insulated to R-6.
Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in
basements.
0 Where exterior walls are used as plenums, the wall is insulated to R-8.
Duct Construction:
o Duct connections to flanges of air distribution system equipment are sealed and mechanically fastened.
All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric,
or tapes. Tapes and mastics are rated UL 181A or UL 181 B.
Exceptions:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa).
Lj The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or floor is provided.
Service Water Heating:
❑ Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat
trap or is part of a circulating system.
Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable
sources. Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Benchmark Homes Job 300 Page 3 of 4
1
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and Runouts
Heated Water
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
Temperature ("F)
170-180
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100-139
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Insulation Thickness in Inches by Pipe Sizes
Piping System Types
Fluid Temp.
Range("F)
2" Runouts 1" and Less
1.25" to 2.0" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
106-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)