Loading...
HomeMy WebLinkAboutRES2007-03348, 07-3349IMMENEFOO7,W33 7FMP City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . . . Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved . . .. . . 3/26/08 244030-0715-0350 3917 LATINNE LN COLLEGE STATION TX 77845 EDELWEISS GARTENS PH 7 EDELWEISS GARTENS PH 7 LOT 35 BLK 15 SINGLE FAMILY RESIDENTIAL CHARLES THOMAS HOMES, INC 979 696-4384 07-00003348 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX B &- ldina Official VOID UNLESS SIGNED BY BUILDING OFFICIAL WF0981674 / 001 City of Colleie ZUation PAGE 1 REQ. DATE: 11/14/07 11/14/07 16:27:51 LOCATION: 3917 LATINNE LN LOC ID: 208890 REQUESTOR: CHARLES THOMAS HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 11/14/07 SCHED COMPLETION: 11/14/07 ******************************************************************************** JOB ORDER RESULT COMMENTS NOW Gina Southerland Re: CAlling for CO for 3917 Latinne Ln Page 11: From: Paul Schoenfeld To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 3/20/2008 2:30 PM Subject: Re: CAlling for CO for 3917 Latinne Ln ALL OK. PAU > Amber Ca r 3/20/2008 9:19 AM >>> p 07-3348 Any issu (1%8/2008) Kim Wolfe -Insulation request inspection result, 3917 Latinne, #07-3348 Page 1 From: Brian Henry To: Southerland, Gina Date: 1/8/2008 9:50 AM Subject: Insulation request inspection result, 3917 Latinne, #07-3348 , CC: Carter, Amber; Wolfe, Kim Print for file Inspected insulation, 3917 Latinne, #07-3348, Charles Thomas Homes, 1-8-08 Inspection result: Inspected OK for Good Cents PREPARED 3/20/08, 11:59:24 INSPECTION TICKET PAGE 10 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/20/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 3917 LATINNE LN SUBDIV: EDELWEISS GARTENS PH 7 CONTRACTOR CHARLES THOMAS HOMES, INC PHONE (979) 696-4384 OWNER . . PHONE PARCEL . . 244030-0715-0350 APPL NUMBER: 07-00003348 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/06/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 12/06/07 AP December 5, 2007 4:36:47 PM acarter. Strings On Setbacks O.K. Slab Ground Installed B115 01 1/04/08 OC BLDG, FRAMING TIME: 17:00 1/04/08 AP January 3, 2008 3:03:27 PM acarter. B130 01 1/08/08 BH BLDG, INSULATION TIME: 17:00 1/08/08 AP January 8, 2008 10:01:59 AM kwolfe. January 8, 2008 10:02:13 AM kwolfe. B125 01 3/20/08 BI Iff; BLDG, FINAL TIME: 17:00 A— March 20, 2008 9:20:58 AM acarter. -------------------------------------- COMMENTS AND NOTES -------------------------------------- 0 � iZ2 LC� �tA i" � 74 ! STALL &D. c Q Vol Date: 3/20/2008 Inspection Comments for Final, Permit Year: 7 permit Number: 334E Address: 3917 LATINNE LN Type inspection Type Code Description status Inspection Result Comments B100 BLDG, FOUNDATION-SLi IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLR IC Slab Ground Installed B130 BLDG, INSULATION IC January 8, 2008 10:02:13 AM kwolfe. E110 ELEC, ROUGH IN IC 01/03/2008 03:48 PM RH PDA E110 ELEC, ROUGH IN IC Need clamp for bond wire at gasline. M110 MECH, FINAL IC February 20, 2008 3:59:08 PM kwolfe. P100 PLBG, ROUGH IN IC November 29, 2007 2:24:07 PM acarter. P100 PLBG, ROUGH IN IC cancelled per john goss P125 PLBG, FINAL IC March 13, 2008 2:58:26 PM kwolfe. Page 1 Mar 26 08 11:38a MACIAS 9797744736 p.2 TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT CHARLES THOMAS HOMESANC. 3997LATINNE 2.334 Percentage of Temjftid (a) to be -a HorizontaliPerimeter FoundalionLSILM .. Primmy RESIDENCE Roof'. A LABEL FOR ANY OTHER PESTFCWE RECOW-NDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY) INCLUDING AREA COVERED, TWE PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE- TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WnlT N THE WARRANTY PERIOD, AND THE CONDRIONS THAT COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED. Charges for pre -treat: NOTES: Annual renewal: .SEE:AT]'ACHED SKETC! BUILDERS SUPPLIES: SKETCH/_PLAi $32.8. $125. C-� L i�k.#-154100 BUIL,AIZL�_ PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 07-00003348, Date 11/14/07 Application pin number . . . 976368 Property Address . . . . . . 3917 LATINNE LN Property ID: 244030-0715-0350 R #. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 7 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 110000 . Owner Contractor ------------------------ ------------------------ CHARLES THOMAS HOMES, INC P.O. BOX 10106 COLLEGE STATION TX 77842 (979) 696-4384 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1621.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 535591 Permit Fee . . . . 490.00 Plan Check Fee .00 Issue Date . . . . 11/14/07 Valuation . . . . 110000 Expiration Date . . 5/12/08 Qty Unit Charge Per Extension BASE FEE 460.00 10.00 3.0000 THOU BLDG, VAL 100001-500000 30.00 ---------------------------------------------------------------------------- Special Notes and Comments -Narrow Wall Bracing Fully Sheathed with Regular Garage Framing with 24" Minimums and Interior 4aracing and Anchors ------------------- BUILDING DE APPLICANT: BUILDING, PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number 07-00003348 Date 11/14/07 Application pin number 976368 ---------------------------------------------------------------------------- Special Notes and Comments to right of Front door area. -Add Smoke detectors in bedrooms and move 3' from return air ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit BUILDING DE APPLICANT: BUILDING.PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00003348 Date 11/14/07 Application pin number . . . 976368 ---------------------------------------------------------------------------- Special Notes and Comments PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR.MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating -------------------------------------------------& - -�-- BUILDING DEPT REW4SENTATIVE: APPLICANT: BUILDING: PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00003348 Application pin number . . . 976368 Page 4 Date 11/14/07 Special Notes and Comments of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 200-o A .40 OR LOWER FACTOR AND ABOVE 200 TO 30% A .35 FACTO OR LOWER SHALL BE MET. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS "REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER T 4" 350.00 -------�--�-----------------------�--- -------------- BUILDING DEPT.RERGz ENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . ... 07-00003348 Date 11/14/07 Application pin number . . . 976368 ---------------------------------------------------------------------------- Other Fees . . . . . . ... . WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid ---------- Credited ---------- Due ---------- ----------------- Permit Fee Total 490.00 490.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1240.00 1240.00 .00 .00 BUILDING DE APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number Application pin number Property Address Property ID: R #• Application type description Subdivision Name . . . . . Property Use . . . . . . . Property Zoning . . . . . . Application valuation . . . 07-00003349 107484 3917 LATINNE LN 244030-0715-0350 Date 11/14/07 TEMP POLE EDELWEISS GARTENS PH 7 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ CHARLES THOMAS HOMES, INC P.O. BOX 10106 COLLEGE STATION TX 77842 (979) 696-4384 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . AC Permit pin number . 535609 Permit Fee . . . . 20.00 Issue Date . . . . 11/14/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited ------------------------------ Due Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 --------------- - - - - BUILDING DE APPLICANT: APPLICATION FOR BUILDING PERMIT ` 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CrrYOF COLLEGE.STAT[ON (979) T64-3570 (979) 764-3496 FAX Plann:ag' _D_kpm gi,$rivide; WW W.CSpTX.GOV ADDRESS/LOCATION: �q ! L_.��# r t LOT BLOCK 'SUBDIVISION _,u Z�S / 5c U DATE:f' I ,EG O APPLICATION # 07 TEMP POLE # BUSINESS/OWNER NAME: CHARLES THOMAS HOMES. INNONE: P.O. BOX 10106 CONTRACTOR/HOMEOWNER: COLLEGE STATION TX 77842 '"PHONE: CONTACT PERSON FOR REVIEW COMMENTS:(2_-inarIES PHONE: 229-botc>lj— FAX: EMAIL: _C_amG7I ll @�llE�l9e�S co ya ELECTRICIAN: _�+_ e PLUMBER: A �.% , HVAC: - ean5GOOD CENTS (Residential only): E6­r y� £ bb ACCESSORY/STORAGE LOCATION RE -ROOF 0A'>'► ADDITION VING DEMOLITION (Asbestos Survey) DUPLEX (Landscape Plans) DESCRIPTION OF WORK: ��VPROPOSED USE: NEW CONSTRUCTION REMODEL/RENOVATION* SHELL ONLY SLAB ONLY SWIMMING POOL TENT/CANOPY HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: �^ TEXAS ACCESSIBILITY STANDARD (fAS) PfjOJECT REGISTRATION# EAB J ' VALUATION:.$ ,/ TOTAL AREA: �EATED AREA Id (Cost of -Labot and Materials) t M PUBLIC SEWER - . . SEPTIC/TREATMENT SY TEM � 35o M R SEWER TAP: WATER TAP: II SIZE OTHER TAP: 6 SIZE TEMP POLE GARAGE TYPE: SINGLE El ATTACHEII Fn NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE TRIPLE DETACHED EJ SIGNATURE OF APPLICANT: *If proposed work involves new commercial cons acad6 improvements/renovations to an existing commercial property, building elevations are required. Official Use Only Q l t - v -7 F/� Plans Examiner � ai4wilLi Ac c es S —A0CS-h) Zoning Official J� e t44 Fire Marshall Comments: Ztq k N�S,0 y p i nor NO v �u fi. 1� ci f of - h�{t�i w�. A-e, .,qi/ O xou ,s ,,to W . v4- Red Df•w& r Energy Code Compliance Information 1 % Glazing of exterior walls - - — Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) 3o- Insulation R value--of-ceiling-2-(vaulted areas/no atfi - / - Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating Protection Against Subterranean Termites heroical Termiticide Treatment Soil Treatmentn C �' ( ) A L� 41S T ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other - *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS Vt*. f/q" CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Services COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# i0j_ 3 DATE: BUILDING ADDRESS: r' N - I. Foundation Requirements- Minimum CiN Foundation Standards NAJOK A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated OK Il. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate Ilk D. Tenant separation in duplex K 1. One -hour rated extending to roof deck O E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. San exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. K AN/OK PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning &Development Ser vices COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements NA/ A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NA/ K 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location 'J CITY OF COLLEGE STATION Planning d Development Serviat PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NAI B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/ A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NA/ A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ K Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 NIA/Plj Does not block any water course or divert any flow Elevation certificate needed N K "APPROVE At� IkANS EXAM ( -[t p L4,fli �-P- " LT 35 Bl k ICI- - �A ` INC I I I �u 'Wa L INE 60,001 L.;4; tQ ,se Lam, E-- CHARLES THOMAS HOMES, INC. P.O. BOX 10106 COLLEGE STATION, TX 77842 MECcheck Compliance Report 2000 IECC MECcheck Software Version 3.2 Release lb TTTLE: College Station Building Permits CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 11/13/07 DATE OF PLANS: 11/14/2007 PROJECT INFORMATION: 3917 Latinne Lane - Edlws Grtns - Ph 7 COMPANY INFORMATION: Charles Thomas Homes, Inc. COMPLIANCE: Passes Maximum UA = 754 Your Home = 537 28.8% Better Than Code Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E Door 1: Solid Door 3: Solid Door 2: Glass Slab 1: Unheated, 0.0' insul. Furnace 1: Forced Hot Air, 80 AFUE Air Conditioner 1: Electric Central Air, 14 SEER Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1621 0.0 30.0 50 1755 13.4 0.0 122 197 0.640 126 20 0.013 0 17 0.013 0 17 0.440 7 223 0.0 232 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed tott2�CC requiremen��Ccheck Version 3.2 Release lb. , Builder/Designer Date ! 7z-c. 0'