HomeMy WebLinkAboutRES2007-03348, 07-3349IMMENEFOO7,W33 7FMP
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . . .
Application number
Description of Work
Construction type . . .
Occupancy type . . . .
Flood Zone . . . . . .
Approved . . .. . .
3/26/08
244030-0715-0350
3917 LATINNE LN
COLLEGE STATION TX 77845
EDELWEISS GARTENS PH 7
EDELWEISS GARTENS PH 7
LOT 35 BLK 15
SINGLE FAMILY RESIDENTIAL
CHARLES THOMAS HOMES, INC
979 696-4384
07-00003348 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
B &-
ldina Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
WF0981674 / 001 City of Colleie ZUation PAGE 1
REQ. DATE: 11/14/07 11/14/07 16:27:51
LOCATION: 3917 LATINNE LN LOC ID: 208890
REQUESTOR: CHARLES THOMAS HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 11/14/07 SCHED COMPLETION: 11/14/07
********************************************************************************
JOB ORDER RESULT COMMENTS
NOW
Gina Southerland Re: CAlling for CO for 3917 Latinne Ln Page 11:
From: Paul Schoenfeld
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 3/20/2008 2:30 PM
Subject: Re: CAlling for CO for 3917 Latinne Ln
ALL OK.
PAU
> Amber Ca r 3/20/2008 9:19 AM >>>
p 07-3348
Any issu
(1%8/2008) Kim Wolfe -Insulation request inspection result, 3917 Latinne, #07-3348 Page 1
From: Brian Henry
To: Southerland, Gina
Date: 1/8/2008 9:50 AM
Subject: Insulation request inspection result, 3917 Latinne, #07-3348 ,
CC: Carter, Amber; Wolfe, Kim
Print for file
Inspected insulation, 3917 Latinne, #07-3348, Charles Thomas Homes, 1-8-08
Inspection result: Inspected OK for Good Cents
PREPARED 3/20/08, 11:59:24
INSPECTION TICKET
PAGE 10
City of
College Station
INSPECTOR: BUILDING
INSPECTOR DATE 3/20/08
------------------------------------------------------------------------------------------------
ADDRESS
. : 3917 LATINNE LN
SUBDIV:
EDELWEISS GARTENS PH 7
CONTRACTOR CHARLES THOMAS HOMES, INC PHONE
(979) 696-4384
OWNER
. .
PHONE
PARCEL
. . 244030-0715-0350
APPL NUMBER: 07-00003348 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
12/06/07 OC
BLDG, FOUNDATION -SLAB TIME:
17:00
12/06/07 AP
December 5, 2007 4:36:47 PM
acarter.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
1/04/08 OC
BLDG, FRAMING TIME: 17:00
1/04/08 AP
January 3, 2008 3:03:27 PM
acarter.
B130 01
1/08/08 BH
BLDG, INSULATION TIME: 17:00
1/08/08 AP
January 8, 2008 10:01:59 AM
kwolfe.
January 8, 2008 10:02:13 AM
kwolfe.
B125 01
3/20/08 BI Iff;
BLDG, FINAL TIME: 17:00
A—
March 20, 2008 9:20:58 AM acarter.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
0 � iZ2 LC� �tA i" � 74 ! STALL &D. c Q
Vol
Date: 3/20/2008
Inspection Comments for Final,
Permit Year: 7 permit Number: 334E
Address: 3917 LATINNE LN
Type
inspection Type Code Description
status
Inspection Result Comments
B100
BLDG, FOUNDATION-SLi
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLR
IC
Slab Ground Installed
B130
BLDG, INSULATION
IC
January 8, 2008 10:02:13 AM kwolfe.
E110
ELEC, ROUGH IN
IC
01/03/2008 03:48 PM RH PDA
E110
ELEC, ROUGH IN
IC
Need clamp for bond wire at gasline.
M110
MECH, FINAL
IC
February 20, 2008 3:59:08 PM kwolfe.
P100
PLBG, ROUGH IN
IC
November 29, 2007 2:24:07 PM acarter.
P100
PLBG, ROUGH IN
IC
cancelled per john goss
P125
PLBG, FINAL
IC
March 13, 2008 2:58:26 PM kwolfe.
Page 1
Mar 26 08 11:38a MACIAS 9797744736 p.2
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
CHARLES THOMAS HOMESANC.
3997LATINNE
2.334
Percentage of Temjftid (a) to be -a
HorizontaliPerimeter
FoundalionLSILM ..
Primmy RESIDENCE Roof'.
A LABEL FOR ANY OTHER PESTFCWE RECOW-NDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY)
INCLUDING AREA COVERED, TWE PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE-
TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WnlT N THE WARRANTY PERIOD, AND THE CONDRIONS THAT
COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED.
Charges for pre -treat:
NOTES: Annual renewal:
.SEE:AT]'ACHED SKETC!
BUILDERS SUPPLIES: SKETCH/_PLAi
$32.8.
$125.
C-� L
i�k.#-154100
BUIL,AIZL�_ PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00003348, Date 11/14/07
Application pin number . . . 976368
Property Address . . . . . . 3917 LATINNE LN
Property ID: 244030-0715-0350
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . EDELWEISS GARTENS PH 7
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 110000 .
Owner
Contractor
------------------------
------------------------
CHARLES THOMAS HOMES, INC
P.O. BOX 10106
COLLEGE STATION
TX 77842
(979) 696-4384
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
N/A
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1621.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TRAFFIC IMPACT ANAL (TAZ)
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
AC
Permit pin number .
535591
Permit Fee . . . .
490.00 Plan Check Fee
.00
Issue Date . . . .
11/14/07 Valuation . . .
. 110000
Expiration Date . .
5/12/08
Qty Unit Charge
Per
Extension
BASE FEE
460.00
10.00 3.0000
THOU BLDG, VAL 100001-500000
30.00
----------------------------------------------------------------------------
Special Notes and Comments
-Narrow Wall Bracing
Fully Sheathed with Regular Garage
Framing with 24" Minimums
and Interior 4aracing and Anchors
-------------------
BUILDING DE
APPLICANT:
BUILDING, PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number 07-00003348 Date 11/14/07
Application pin number 976368
----------------------------------------------------------------------------
Special Notes and Comments
to right of Front door area.
-Add Smoke detectors in bedrooms and move 3' from return air
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
BUILDING DE
APPLICANT:
BUILDING.PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 07-00003348 Date 11/14/07
Application pin number . . . 976368
----------------------------------------------------------------------------
Special Notes and Comments
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR.MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
-------------------------------------------------& - -�--
BUILDING DEPT REW4SENTATIVE:
APPLICANT:
BUILDING: PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00003348
Application pin number . . . 976368
Page 4
Date 11/14/07
Special Notes and Comments
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 200-o A .40 OR LOWER FACTOR AND ABOVE 200
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
"REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER T 4" 350.00
-------�--�-----------------------�--- --------------
BUILDING DEPT.RERGz ENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 5
Application Number . . ...
07-00003348
Date 11/14/07
Application pin number . . .
976368
----------------------------------------------------------------------------
Other Fees . . . . . . ... .
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid
----------
Credited
----------
Due
----------
-----------------
Permit Fee Total 490.00
490.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total 1240.00
1240.00
.00
.00
BUILDING DE
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
Application pin number
Property Address
Property ID:
R #•
Application type description
Subdivision Name . . . . .
Property Use . . . . . . .
Property Zoning . . . . . .
Application valuation . . .
07-00003349
107484
3917 LATINNE LN
244030-0715-0350
Date 11/14/07
TEMP POLE
EDELWEISS GARTENS PH 7
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
------------------------
CHARLES THOMAS HOMES,
INC
P.O. BOX 10106
COLLEGE STATION
TX 77842
(979) 696-4384
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. AC
Permit pin number
. 535609
Permit Fee . . .
. 20.00
Issue Date . . .
. 11/14/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
------------------------------
Due
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
--------------- - - - -
BUILDING DE
APPLICANT:
APPLICATION FOR BUILDING PERMIT
` 1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CrrYOF COLLEGE.STAT[ON (979) T64-3570 (979) 764-3496 FAX
Plann:ag' _D_kpm gi,$rivide;
WW W.CSpTX.GOV
ADDRESS/LOCATION: �q ! L_.��#
r t
LOT BLOCK 'SUBDIVISION _,u Z�S
/ 5c U
DATE:f' I ,EG O
APPLICATION #
07 TEMP POLE #
BUSINESS/OWNER NAME: CHARLES THOMAS HOMES. INNONE:
P.O. BOX 10106
CONTRACTOR/HOMEOWNER: COLLEGE STATION TX 77842 '"PHONE:
CONTACT PERSON FOR REVIEW COMMENTS:(2_-inarIES PHONE: 229-botc>lj—
FAX: EMAIL: _C_amG7I ll @�llE�l9e�S co ya
ELECTRICIAN: _�+_ e PLUMBER: A �.% ,
HVAC: - ean5GOOD CENTS (Residential only): E6r y� £
bb
ACCESSORY/STORAGE LOCATION RE -ROOF 0A'>'►
ADDITION VING
DEMOLITION (Asbestos Survey)
DUPLEX (Landscape Plans)
DESCRIPTION OF WORK:
��VPROPOSED USE:
NEW CONSTRUCTION
REMODEL/RENOVATION*
SHELL ONLY
SLAB ONLY
SWIMMING POOL
TENT/CANOPY
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
�^ TEXAS ACCESSIBILITY STANDARD (fAS) PfjOJECT REGISTRATION# EAB J
' VALUATION:.$ ,/ TOTAL AREA: �EATED AREA Id
(Cost of -Labot and Materials)
t
M PUBLIC SEWER - . .
SEPTIC/TREATMENT SY TEM
� 35o
M
R SEWER TAP:
WATER TAP: II
SIZE
OTHER TAP:
6
SIZE
TEMP POLE
GARAGE TYPE: SINGLE El
ATTACHEII Fn
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE TRIPLE
DETACHED EJ
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial cons acad6 improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
Q l t - v -7
F/� Plans Examiner
� ai4wilLi Ac c es S
—A0CS-h)
Zoning Official J� e t44 Fire Marshall
Comments: Ztq k N�S,0
y p i
nor NO v �u fi. 1� ci f of - h�{t�i w�. A-e, .,qi/
O xou ,s ,,to W . v4- Red Df•w&
r
Energy Code Compliance Information
1
% Glazing of exterior walls - - —
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas) 3o-
Insulation R value--of-ceiling-2-(vaulted areas/no atfi - / -
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
heroical Termiticide Treatment Soil Treatmentn
C �' ( ) A L� 41S T
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other -
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
Vt*. f/q" CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# i0j_ 3
DATE:
BUILDING ADDRESS:
r' N -
I. Foundation Requirements- Minimum CiN Foundation Standards
NAJOK
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
OK
Il. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
Ilk
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
O
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
San exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
K
AN/OK
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning &Development Ser vices COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/ K
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
'J
CITY OF COLLEGE STATION
Planning d Development Serviat
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NAI
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NA/
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/ K
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
NIA/Plj
Does not block any water course or divert any flow
Elevation certificate needed
N K
"APPROVE
At�
IkANS EXAM
( -[t p L4,fli �-P- "
LT 35 Bl k ICI- - �A
`
INC
I I
I
�u
'Wa L INE
60,001
L.;4; tQ ,se Lam, E--
CHARLES THOMAS HOMES, INC.
P.O. BOX 10106
COLLEGE STATION, TX 77842
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release lb
TTTLE: College Station Building Permits
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 11/13/07
DATE OF PLANS: 11/14/2007
PROJECT INFORMATION:
3917 Latinne Lane - Edlws Grtns - Ph 7
COMPANY INFORMATION:
Charles Thomas Homes, Inc.
COMPLIANCE: Passes
Maximum UA = 754
Your Home = 537
28.8% Better Than Code
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane with Low-E
Door 1: Solid
Door 3: Solid
Door 2: Glass
Slab 1: Unheated, 0.0' insul.
Furnace 1: Forced Hot Air, 80 AFUE
Air Conditioner 1: Electric Central Air, 14 SEER
Permit Number
Checked By/Date
Gross
Glazing
Area or Cavity
Cont.
or Door
Perimeter R-Value
R-Value
U-Factor
UA
1621 0.0
30.0
50
1755 13.4
0.0
122
197
0.640
126
20
0.013
0
17
0.013
0
17
0.440
7
223
0.0
232
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building
plans, specifications, and other calculations submitted with the permit application. The proposed building has
been designed tott2�CC requiremen��Ccheck Version 3.2 Release lb.
,
Builder/Designer Date ! 7z-c. 0'