WF0984947 / 001 City of College ,Station
PAGE 1
REQ.-DATE: 11/30/07 11/30/07 13:52:52
LOCATION: 1209 EBBTIDE CV LOC ID: 209060
REQUESTOR: SIERRA VISTA CONSTRUCTION ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
.WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 11/30/07 SCHED COMPLETION: 11/30/07
********************************************************************************
JOB ORDER RESULT COMMENTS
(2/29/2008) Kim Wolfe Insulation request inspection _result: -1209 Ebbtide Cv #07-3327 Page 1 s
From: Brian Henry
To: Southerland, Gina
Date: 2/29/2008 11:23 AM
Subject: Insulation request inspection result: 1209 Ebbtide Crr`#07-3327
CC: Carter, Amber; Wolfe, Kim
Print for file
Inspected insulation, 1209 Ebbtide Cv. #07-3327, Sierra Homes, 2-29-08
Inspection resutl: Inspected OK for Good Cents
Notes:
Tape the bottom of all windows on the exterior.
INTERIOR BEAM BARS ®16O.C. EXTERIOR BEAM
brick
lodg
6. F
.. ........................................................................\ .....................................
4 06 or 4 #6
6 #S or
BARS _ 6 #6
BARS
3-
Vapor Retarder N 7or
(min. 6 mil poy) 3' E
STIRRUPS M
4' 14• 03 BARS a 48- O4- —14' .
4 pa. WWM a 24.
6 go. WWM a 18' O.C.
INTERIOR SLAB DROP
.............................................................................. ......
��-1
6'min.
GENERAL NOTES:
1. Exterior beam shall extend a minimum of 6 inches into undisturbed soil or fill which is
compacted to 95 % Standard Proctor (ASTM D 698) within ( +, 2 % of optimum
moisture content. All fill material shall have a Plasiticity Index (P.I.) between
5 and 18.
2. Interior beams that exceed 60 ft In length must be a minimum of 30" deep.
3. Maximum beam spacing shall be 15 feet and shall be continuous over the length or
width of the foundation.
4. Steel to be set to clear bare earth minimum 3". wood or steel form 1 -1/2".
5. Minimum concrete specified compression strength shall be 3000 psi @ 28 days.
6. Masonry fireplace footings shall be a minimum of 30".deep with 2 mats of #5's @
12" O.C. both ways.
7. These minimum standards shall apply to all foundations.
Exceptions:
A. Foundations for temporary buildings and permanent buildings not exceeding
one story in height and 400' square feet in area.
B. Foundations designed by an Architect registered in the State of Texas or a
civil/structural Engineer registered in the State of Texas and approved for use
by the Building Official.
8. All foundations designed by an Architect or Engineer shall be installed
as designed. Revisions and exceptions must be submitted in writing by
the Architect or Engineer and approved by the Building Official.
9. Reinforcing steel shall be grade 60 (grade 40 allowed for stirrups only).
All deformations shall meet ASTM A615.
Page 46 of 69
BAR
Sig
MIN. W.
INCHES
MNIMUM nAD1US
OF BENDS
#3
12"
15/16"
#4
12"
1-1/4"
#5
15"
1-9/16"
#6
20"
2-1/4"
#7
26"
2-5/8"
#8
35"
3"
0..vbbn Owalptbn DA
BUILDING DIVISION
CITY OF COLLEGE STATION
MINIMUM
FOUNDATION
STANDARDS
s¢E A vaEvuiEo 12104 " 1 0, 1
Rev. 03/05
/1
SCALE: 1 " = 30'
5/8 INCH IRON
ROD FOUND - CM
bo1 /
/
/ SURVEYOR'S CERTIFICATE:
/ I, BRAD KERR, R.P.L.S. NO. 4502, DO HEREBY CERTIFY THAT TO THE BEST OF MY KNOWLEDGE THIS
PLAT IS A TRUE REPRESENTATION OF A SURVEY MADE ON THE GROUND UNDER MY SUPERVISION AND
THAT THERE ARE THIS N TRACT DOES NOT ILIE LWITHIN RAADESIGNATED CHMENTS Ni OI YEAR FLOOD PLAIN ACCORDING THEREON.S TRACT EXCEPT AS SHOWN
O
THE F.I.R.M. MAPS, COMMUNITY PANEL NO. 48041 CO205 D, EFFECTIVE DATE: 02-09-2000.
BRAD KERR
/ REGISTERED PROFESSIONAL
/ LAND SURVEYOR NO. 4502
5/8 INCH IRON
/
/
LOT 6
BLOCK
4
ROD FOUND - CM
/ 40' BUFFER
/
ZONE /
/
�cl
/ `j% �O.
s10, `r�0 S>�
LOT 7
UTILITY
EASEMENT
BLOCK 4 ?,. s F
/
or
/ 10' PUBLIC UTILITY
/ EASEMENT
h
S�
�0. `O�'1 1O.
0- s�9�• , /
5/8 INCH
ROD SET IRON
/
LOT 8
BLOCK
r0 :s
4
PROPERTY LINE DIMENSIONS SHOWN HEREON
ARE PLAT CALL AND MEASURED.
BUILDING SETBACK LINES PER CITY OF COLLEGE
STATION U.0.0 AND PLAT,
CM - CONTROLLING MONUMENT FOUND AND
USED TO ESTABLISH PROPERTY LINES.
BEARING SYSTEM SHOWN HEREON IS HONORING
THE PLAT CALLED BEARINGS AS SHOWN ON THE
PLAT RECORDED IN VOL. 8021. PG. 119, AND
AS MONUMENTED ON THE GROUND.
Z/ 5/8 INCH IRON
/ ROD SET
/
5
ST
3
o 'aacee r:�oo ,oa�aoae
5RAD K7RR
a aaG•OcoaaC"JCaG000°aa
a
a
/J�
L!�.?��
FORM SURVEY
OF
LOT 7, BLOCK 4
SOUTH HAMPTON SUBDIVISION, PHASE 2
VOLUME 8021, PAGE 119
COLLEGE STATION, BRAZOS COUNTY, TEXAS
SCALE: 1 INCH = 30 FEET
SURVEY'DATE: 12-11-07
PLAT DATE: 12-12-07
JOB NUMBER: 07-956
CAD NAME: 07-956A
CR5 FILE: HAMPTON (cont); 07-956A (job)
PREPARED BY: KERR SURVEYING, LLC
505 CHURCH AVENUE, P.O. BOX 269
COLLEGE STATION, TEXAS 77841
PHONE (979) 268-3195
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #:
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00003327
877958
1209 EBBTIDE CV
579020-0204-0070
Date 11/30/07
RESIDENTIAL, 1 UNIT DETACHED NEW
SOUTH HAMPTON PH 2
RESIDENTIAL
PLANNED DEVL DISTRICT
157740
Owner
Contractor
------------------------
------------------------
SIERRA VISTA CONSTRUCTION
6029 MELROSE AVE
SAN ANGELO
TX 76901
(325) 942-8999
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
N/A
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2390.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.50
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TRAFFIC IMPACT ANAL (TAZ)
447.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
Permit pin number .
537928
Permit Fee . . . .
634.00 Plan Check Fee
.00
Issue Date . . . .
11/30/07 Valuation . .
. . 157740
Expiration Date . .
5/28/08
Qty Unit Charge
Per
Extension
BASE FEE
460.00
58.00 3.0000
THOU BLDG, VAL 100001-500000
174.00
------------------------------------------ ----------------------------------
Special Notes and Comments
-Narrow Wall Bracing
Fully Sheathed with 18" Minimum APA
Garage Framing
1 1,7 'y i _
------------------
BUILDING .T=
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00003327
Application pin number . . . 877958
Page 2
Date 11/30/07
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
--------BUILDING D REhPRF�ENTAT-TVE'--,�� --fit-_� ---------
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 07-00003327 Date 11/30/07
Application pin number . . . 877958
----------------------------------------------------------------------------
Special Notes and Comments
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR -ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS.ON SITE LOCATED OFF
BUILDING
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number 07-00003327 Date 11/30/07
Application pin number . . . 877958
----------------------------------------------------------------------------
Special Notes and Comments
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 2001 A .40 OR LOWER FACTOR AND ABOVE 20%
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4". 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Pail Cr dite - Due
------------------- -----------------------------�!-- ---- -------------
BUILDING 3E�''� EP�'B'ENT4I E : .
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Permit Fee Total 634.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1384.00
-----------------
BUILDING
APPLICANT
07-00003327
877958
634.00
.00
.00
.00
750.00
.00
1384.00
.00
Page 5
Date 11/30/07
.00
.00
.00
.00
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00003328
Date 11/30/07
Application pin number . . .
030912
Property Address . . . . . .
1209 EBBTIDE CV
Property ID:
579020-0204-0070
Application type description
TEMP POLE
Subdivision Name . . . . . .
SOUTH HAMPTON PH 2
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
PLANNED DEVL DISTRICT
Application valuation
0
Owner
Contractor
------------------------
------------------------
SIERRA VISTA CONSTRUCTION
6029 MELROSE AVE
SAN ANGELO
TX 76901
(325) 942-8999
-------=--------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . .
Permit pin number . 537944
Permit Fee . . . . 20.00
Issue Date . . . . 11/30/07
Valuation . .
. . 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
---------------------------
Paid Credited
--------------------
Due
----------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
-----------------
BUILDING
APPLICANT
CITY OF COLLEGE STATION.
P14nning0,'Dfji47pme iSeroitu'
ADDRESS/ALLOCATION:_
LOT _a" BLOCK A
APPLICATION FOR 3UILD!NG PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
a oq b�h'� �, Cv �, ✓�
BUSINESS/OWNER NAME
DATE:
APPLICATION #
TEMP POLE # 07�3 R9
� �-D4
� c 1
_ SUBDIVISION _ )j��lL�C�IYiII I�i� (�i ✓ SEC/PHA
� J ) ec r &, V ) s l Q__- l�l l7� 1 PHONE: 9l 7 - 499 r�' (SC
CONTRACTOR/HOMEOWNER: l I hc1C� PHONE: '1 'j"`'( -- 49 2 - la i ce
CONTRACTOR ADDRESS: - t21A?> (mar kr CreeIL VP,1,)y ID3 brc��
ELECTRICIAN G�� `�� �Cti PLUMBER: —FA "Y ILlh(Ibl (rl G
HVAC: Ci1 gtr GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ` SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
I I I A o TENT/CANOPY
DESCRIPTION OF WORK: '1���QE'lI�T1CSL \U1�
I
PROPOSED USE: 'L`JIG�Y1`�l(
HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION## EEABPRJ r�2
VALUATION: $ _,4�A 5 ' o TOTAL AREA:,IL,�— HEATED AREA:C- cL lO
(Cost of LVbor and Materials)
NUMBER OF BEDROOMS: 4
NUMBER OF BATHROOMS: ;? , J
INTERIOR WALL_ YPE: 1 WGcJ \
f
EXTERIOR WA C
FOUNDATION TYPE: J 1
ROOF TYPE: U a
i
DOUBLE E2r TRIP
F9ra _oa'&k
ATTACHED DETACHED F] CARPORT
SIGNATURE OF APPLICANT: 1
*If proposed work involves new commercial constructiori or facade improvements renovations to an ex
\ commercial property, building elevations are required.
Official Use Only
Plans Examiner
PP
1� w1 h pAcceSS
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
r1
SEWER TAP:
SIZE
3
WATER TAP: U
SIZE
OTHER TAP:
bIZE
POLE
GARAGE TYPE: SINGLE El
Zoning Official
Comments:
nor NO
Fire Marshall
L jw'5fv tiII.L BA04tio/t-
G AX&O A4-P 4i
Energy Code Compliance Information
% Glazing of exterior walls / D
Insulation R value of exterior walls
•R 13 �
Insulation R value of ceiling 1 (flat areas)
J
Insulation R value of ceiling 2 (vaulted areas/ho attic) v
Glazing SHGC 40
Glazing U-Factor
R value of ductwork "
A/C SEER Rating 3
PLAN- REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning d Development Services COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# Q 7 _ 3
DATE:
', _ 3 _ O -7
BUILDING ADDRESS:
z o E 'alco v
I. Foundation Requirements- Minimum City Foundation Standards
NA/
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
A/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing plan or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
San exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size,
location indicated on plans
grade &
Q. Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
/OK
/OK
J PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning dDrvrlopmrnrSmica COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N /
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NAM
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NAICA
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
N K
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
jZ J_ - -
PLANS EXAMINER
11 ��vo-7
DATE