Loading...
HomeMy WebLinkAboutCNEW2007-03308o� City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address Subdivision Name Legal Description . . . Property Zoning . . Owner . . . . . . . Contractor . . . . Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved 1/18/08 134500-0203-0010 1602 ROCK PRAIRIE RD 3000 COLLEGE STATION TX 77845 BELMONT PLACE #2 BELMONT PLACE #2, BLOCK 3, LOT 1R (PT OF) & ADJ .44 AC "COLLEGE STATION MEDICAL CENTER" (SEE R116787 & R305098 GENERAL COMMERCIAL COLLEGE STATION HOSPITAL L.P. KEYS & WALSH CONSTRUCTION, LLC 979 693-3200 07-00003308 000 000 COMMERCIAL, OFFICES/BANKS/PROFESSION NON-COMBUSTIBLE BUSINESS ...... C�AA4 Building Official VOID UNLESS SIGNED BY BUILDING OFFICIAL (1/16/2008) GinaPSoutherland - Re: Calling for CO@ 1602 Rock Praise Rd. #300 Page 1 From: James Boykin To: Alan Gibbs; Amber Carter; Benjamin McCarty; Brian Wells; Carol Cotte... Date: 1/16/2008 2:56 PM Subject: Re: Calling for C.O. @ 1602 Rock Prairie Rd. #300 Environmental Services has no issues. Okay for CO. James Boykin Environmental Technician Water Services Department 979-764-6312 >>> Gina Southerland 1/16/2008 9:13 AM >>> Finish Out for a medical office BP# 07-3308 Contact Info: Ronnie with Keys & Walsh @ 219-6624 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.gov - (f 1%16/2008) Gina Southerland - Re: Calling for C.O. @ 1602 Rock Prairie Rd. #300 Page 1 From: Lindsay Boyer To: Gina Southerland Date: 1/16/2008 10:15 AM Subject: Re: Calling for C.O. @ 1602 Rock Prairie Rd. #300 No issues for planning, interior finish out >>> Gina Southerland 1/16/2008 9:13 AM >>> Finish Out for a medical office BP# 07-3308 Contact Info: Ronnie with Keys & Walsh @ 219-6624 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csbc.00v (1/16/2008) Gina Southerland - Re: Calling for C.O. @ 1602 Rock Prairie Rd. #300 Page 1 From: Paul Schoenfeld To: Alan Gibbs; Amber Carter; Benjamin McCarty; Brian Wells; Carol Cotte... Date: 1/16/2008 10:20 AM Subject: Re: Calling for C.O. @ 1602 Rock Prairie Rd. #300 ALL OK. PAUL >>> Gina Southerland 1/16/2008 9:13 AM >>> Finish Out for a medical office BP# 07-3308 Contact Info: Ronnie with Keys & Walsh @ 219-6624 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.00v . �. _—. __w - . (1/16%2008) Gina Southerland - Re: Calling for C.O. @ 1602 Rock Prairie Rd. #300 w � � Page 1 From: To: Date: Subject: OK with Drainage. Donnie Willis Southerland, Gina 1/16/2008 9:47 AM Re: Calling for C.O. Donnie Willis, CFM Environmental Engineering Technician Certified Floodplain Manager Public Works Department 979-764-6375 office 979-229-7632 cell dwillis@cstx.gov @ 1602 Rock Prairie Rd. #300 >>> On 1/16/2008 at 9:13 am, in message <478DCAC6.6D9C.0039.0@cstx.gov>, Gina Southerland wrote: Finish Out for a medical office BP# 07-3308 Contact Info: Ronnie with Keys & Walsh @ 219-6624 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csb(.gov (1/16/2008) Gina Southerland - Re: Calling for C.O. @ 1602 Rock Prairie Rd. #300 Page 1 From: Tony Michalsky To: Gina Southerland Date: 1/16/2008 9:47 AM Subject:. Re: Calling for C.O. @ 1602 Rock Prairie Rd. #300 ok with us >>> Gina Southerland 1/16/2008 9:13 AM >>> Finish Out for a medical office BP# 07-3308 Contact Info: Ronnie with Keys & Walsh @ 219-6624 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csbc.gov PREPARED 1/16/08, 12:08:14 INSPECTION TICKET PAGE 20 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 1/16/08 ------------------- _----,-------------------------------------------------------------------------- ADDRESS 1602 ROCK PRAIRIE RD 3000 SUBDIV: BELMONT PLACE #2 TENANT, NBR :FI S OUT/MEDICAL OFFICE CONTRACTOR KEYS & WALSH CONSTRUCTION, LLC PHONE (979) 693-3200 OWNER COLLEGE STATION HOSPITAL L.P. PHONE PARCEL 134500-0203-0010 APPL NUMBER: 07-00003308 COMMERCIAL, OFFICES/BANKS/PROFESSION ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B115 01 12/18/07 RH BLDG, FRAMING TIME: 17:00 12/18/07 AP December 18, 2007 9:47:00 AM kwolfe. 'B12;5 01_ / /08 BI BLDG, FINAL TIME: 17:00 d 4 January 16, 2008 8:33:50 AM glsouth. --------------------------"----- CONTINUED ONTO NEXT PAGE----------------------------------- 0\qV Date I 'O Permit #61 •i: Project Name COMMERCIAL CO Planning Jy (Lindsay Boyer, Jennifer Prochazka, Jennifer Reeves, Crissy Hard, Jason Schubert, Grant Wencel, Molly Hitchcock) Bridgette George Development Engineers (Alan Gibbs, Josh Norton, Carol Cotter) City Engineer (Bob Mosley, Jerry Jones, John Logan, Robert Bumpurs, William Ethridge) Environmental Services (Eaphrame Thomas, James Boykin, Pete Garcia) Fire Department (Eric Hurt, Eric Dotson, Jerry Duffey, Steve Smith) Drainage 04- (Donnie Willis) Public Works - Sanitation (Wally Urrutia) Electrical Services (Tony Michalsky) Water/Wastewater Services (Joe Mike Garcia Paul Schoenfeld, Mitchell Miscellaneous Notes 0�- �1.330� OCollege Station Fire Department INSPECTION/TEST REQUEST Ct_>l Location of Inspection/Test: ��,ti✓ r • ter. ' � . v . _. � � _ Business/Job Phone: 7 t 13 (;. 7� z v Applicant Name: Address: Phone: -)� fr; Date of Application: INSPECTION/TEST FEE AMT. DUE DayCare Inspection......................................................................... $30.00 .............. $ Foster Home Inspection................................................................... $30.00 .............. $ Nursing Home Inspection................................................................. $50.00 .............. $ Health Care Facility Inspection . $50.00 ..........:... $ Fire Sprinkler/Standpipe Test, up to 100.......................................... $50.00 .............. $ Each 100 thereafter, or fraction ..... # heads @ $50.00/100 .............. $ Automatic Hood Fire Extinguisher Test ............................................ $30.00 .............. $ Fuel Tank Leak Test......................................................................... $50.00 .............. $ Fuel Line Leak Test.......................................................................... $50.00 .............. $ Automatic Fire Alarm System Test, up to 25 initiating devices ......... $30.00 $ Each 100 thereafter, or fraction .... # devices @ $50.00/100 .............. $ Natural Gas System Test.................................................................. $30.00 .............. $ Inspections Outside City Limits Standard Fee: x 1.5 = Vehicle Mileage: Total Travel Time: x 0.325 = x 20.00 = Total Inspection Fee: $ TOTAL AMOUNT DUE: $� PLEASE NOTE: Re -tests and re -inspections will be billed at the same rate as the initial test or inspection. White: Applicant Yellow: Fire Marshal Pink: Building 0 CITY OF Cfn.t.M STATION R R P R 1 0 T 4£i CUSTOMER RECEIPT tat 0917 A rType; CT Draver: 1 Date: 1/16/08.69 Receipt no. 1 Description guantit A:aouni C8 pum FIR, A6/881 E8 Lee $30. es AWO FIRE ALARM/801 1. Rfl $30.09 Tender detail CH PEAL 1618 ;Q, g0 Total tendered $60.83 Total payment $60.08 Trans date: %,1/16/88 Time: 9:35:38 THM you BUILDING PERMIT CITY OF COLLEGE STATION, 1101 TEXAS AVENUE, COLLEGE STATION1 TX 77840 PHONE: (979)764-3570 FAX: (979)76473496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Tenant nbr, name . . . . . . Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner 07-00003308 Date 12/04/07 804860 1602 ROCK PRAIRIE RD 3000 134500-0203-0010 R80075 FINISH OUT/MEDICAL OFFICE COMMERCIAL, OFFICES/BANKS/PROFESSION BELMONT PLACE #2 GENERAL COMMERCIAL 120000 COLLEGE STATION HOSPITAL L.P. COLLEGE STATION MEDICAL CTR 1604 ROCK PRAIRIE RD COLLEGE STATION TX 778458345 Contractor KEYS & WALSH CONSTRUCTION, LLC 232 SOUTHWEST PKWY E COLLEGE STATION TX 77840 (979) 693-3200 --- Structure Information 000 000 MEDICAL OFFICE TENANT FINISHOUT Construction Type . . . . . NON-COMBUSTIBLE Occupancy Type . . . . . . BUSINESS Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB HEATED AREA 1575.00 INTERIOR WALL TYPE DRYWALL SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 391.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 538538 Permit Fee . . . . 520.00 Plan Check Fee .00 Issue Date . . . . 12/04/07 Valuation . . . . 120000 Expiration Date . . 6/01/08 Qty Unit Charge Per Extension BASE FEE 460.00 20.00 3.0000 THOU BLDG, VAL 100001-500000 60.00 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ADDRESS ON COMMERCIAL BUILDINGS -FRONT: 5" ADDRESS NUMBERS, AND ON REAR DOOR(S): 2" HIGH ADDRESS NUMBERS AND NAME OF BUSINESS. FOR MULTI -FAMILY RESIDENTIAL PROVIDE UNIT NUMBER ON FRONT DOOR AND IDENTIFY EACH UNIT FROM A REAR FIRE -------------------------------------------- -------- ------ -------------- BUILDING DEPT REP NTATIVE: APPLICANT: ,� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION,. TX 77840 PHONE: (979)764-3570 FAX: (979)7.64-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 07-00003308 Date 12/04/07 Application pin number . . . 804860 ------------------------------------7--------------------------------------- Special Notes and Comments LANE. IDENTIFY MULTI -FAMILY BUILDINGS WITH 12" BUILDING NUMBERS, VISIBLE FROM ALL ADJACENT/NEARBY FIRE LANES. ALL NUMBERS AND LETTERS SHALL HAVE CONTRASTING BACKGROUNDS. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE PROVIDE COMBUSTION AIR: FOR GAS -FIRED APPLIANCES PER SECTION 304 OF THE 2006 INTERNATIONAL FUEL GAS CODE; FOR OTHER FUELS TO COMPLY WITH CHAPTER 7 OF THE 2006 IMC. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS SUBMIT FIRE ALARM PLANS WITH PRODUCT DATA SHEETS - DESIGN AND INSTALL AS PER NFPA 72 NO WORK SHALL START UNTIL PLANS HAVE BEEN REVIEWED AND RETURNED PROVIDE FIRE EXTINGUISHER(S) - VERIFY LOCATION AND PLACEMENT WITH THE FIRE MARSHALL'S OFFICE (MIN. 2A10BC) SUBMIT FIRE SPRINKLER PLANS AND CALCULATIONS FOR REVIEW NO WORK ON SPRINKLER SYSTEM SHALL BEGIN UNTIL PLANS HAVE BEEN REVIEW AND RETURNED. SPRINKLER SYSTEM CONTROLS AND WATER FLOW SWITCHES ARE REQUIRED TO BE MONITORED BY AN APPROVED MONITORING COMPANY. A COPY OF THE MONITORING CONTRACT SHALL BE SENT TO THE COLLEGE STATION FIRE DEPARTMENT, FIRE PREVENTION DIVISION. PROVIDE MINIMUM 42" CLEARANCE FROM CENTER LINE OF WATER CLOSET TO EDGE OF LAVATORY OR WALL TO COMPLY WITH ANSI 2003, ACCESSIBLE STANDARDS. PROVIDE A KNOX BOX FOR FIRE DEPARTMENT ACCESS. A KEY FOR EACH SHELL BUILDING AND/ OR TENANT DOOR IS REQUIRED. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT INTERIOR LIGHTING SHALL MEET THE CONTROLS AND WATTAGE REQUIREMENTS OF SECTION 505 OF THE 2006 INTERNATIONAL ENERGY CONSERVATION CODE. CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) PROVIDE PANIC HARDWARE ON EXIT DOORS ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION,:TX 7`7840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00003308 Date 12/04/07 Application pin number 804860 ---------------------------------------------------------------------------- Special Notes and Comments CONSTRUCTION CONTRACTS OVER $50,000 REQUIRE SUBMISSION TO THE STATE FOR ACCESSIBILITY REVIEW - CONTACT TDLR @ (512) 463-3211 FOR MORE INFORMATION TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 520.00 520.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 520.00 520.00 .00 .00 ----------------- --- - -- ------ BUILDING DEPT REP✓t�RNTATIVE: / APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE (*//qq44 COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning d Devtlopmtnt Srrvirrf WWW.CSTX.GOV ADDRESS/LOCATION: l uo zi !�;T4_ �J LOT BLOCK SUBDIVISION For Offlae Use Only DATE: c TRCC RE'GG APPLICATION # J TEMP POLE # � A //�� SEC/PH BUSINESS/OWNER NAME: 7e�S f u( l� 1 c_41. k9ve—�9T9 PHONE: "7 f��-mot V_V r CONTRACTOR/HOMEOWNER: ' Ii1S 4 w�-S C��-`Y PHONE: 1973'�3ZD� CONTACT PERSON FOR REVIEW COMMENTS: )<[_ V,V k L­�>kf PHONE:We-Yn'-4Lu FAX: f��Z2i'7Zzs EMAIL: ELECTRICIAN: C_LLE Tt0f i PLUMBER: 2c-�4�/ T C ✓"'� `�- GOOD CENTS (Residential only): ACCESSORY/STORAGE MOVING RE -ROOF ADDITION NEW CONSTRUCTION* SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION REMODEL/RENOVATION* DESCRIPTION OF WORK: &T PcP_ `v `ti�Ct PROPOSED USE: ��c cPL STRUCTURE USE: UGe>. HOMEOWNER ASSOC IATION/ARC HITECTUAL OR DESIGN REVIEW COMMITTE APP OVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ � RoIII v t �• o VALUATION: $ 1 1,01 mr-) TOTAL AREA: IS� S HEATED AREA: I J (Cost 6f Labor and Materials) UBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM ❑ SEWER TAP: N e, SIZE WATER TAP: A hSIZE OTHER TAP: (•v/I� SIZE TEMP POLE GARAGE TYPE: SINGLE a ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE F1 DETACHED TRIPLE CARPORT SIGNATURE OF APPLICANT: *If proposed work involves new co ercial construction or facade improvements/renovations to an existing commercial property, building el ations are required. .......................................................... Official Use Only NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating Protection Against Subterranean Termites ❑ Chemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. EDDIE HARE -ACCESSIBILITY SPECIALIST TDLR/TAS Registered Accessibility Specialist #0008 5855 Foster Road * Bryan, Texas 77807 (979) 775-6850 office * (979) 775-6820 fax * (979) 228-1776 * (877) 381-9685 toll free October 6, 2007 EABPRJA8801961 Mr. Charles N. Burris The Arkitex Studio 308 N. Bryan Avenue Bryan, Texas 77803 Re: Expansion of Brazos Medical Associates * C/S Med Plaza East * 1602 Rock Prairie Road, #3000 College Station, Texas 77845 Dear Mr. Burris: The construction documents for this projecthavebeen revicwed.and approved by this office for purposes of ensuring compliance with the provisions of the Texas Architectural Barriers Act, adopted by the Texas Department of Licensing and Regulation for the purposes of ensuring compliance with the provisions of Chapter 469, Elimination of Architectural Bamers. The iesults of this report do not address the Americans with Disabilities Act (ADA, P.L. 101-336) or any other federal, state, or local requirement. For information on the ADA Hotline, (800) 949-4232, or the United States Department Of Justice at (202) 514-0301. A written response to this report is not required. If you have any questions, contact me at the above referenced address or phone numbers. Please reference the EABPRJ number in all future correspondence pertaining to this project. The building or facility owner must request an inspection from the Department or a Registered Accessibility Specialist (RAS) no later than 30 days after completion of construction. Sincerely, Eddie Hare Accessibility Specialist ICBO#1131801-21 RAS# 0008 THE REVIEW OFDOCUMENTSAS CONTRACT DOCUMENTS AND FIELD INSPECTIONS, BY THIS REGISTERED ACCESSSIBLITY SPECIALIST, EDDIE HARE, FOR THE TEXASDEPARTMENT OFLICENSING AND REGULATION (TDLR), AUSTIN, TEXAS, IS BASED ON BEST EFFORTS ENDEAVOR FOLLOWM INSTRUCTIONAND CERTIFICA770N BY BOTH TDLR AND ICBO. PLAN REVIE{f AND INSPECTION INNO WAY {VARRANn COMPLETE COMPLIANCE TO THE TEXASACCESSIBLITYSTANDARDS THIS BUSINESS, THE PROFESSIONAL, HIS EMPLOYEES, AND CLIENT FOR WHOM THE REVIEW OR INSPECTTONIS MADE AGREES TO HOLD HARMLESSAND INDEMNIFY WE REGISTERED ACCESSIBILTYSPECIALIST, EDDTE HARE, AND THE TDLR FROMAND AGAINST ANYLIABILITYARISING FROMTHE PERFORMANCE OF THE WORK ABProjRegForm Page 1 of 1 Texas Department of Licensing and Regulation Architectural Barriers Project Registration Confirmation Page Wednesday, October 03, 2007 EABPRJAB801961 PERSON FILING FORM Name: Eddie Hare Emall:hares3211@msn.com Phone: 979-820-0149 RAS Number: 00000008 Project Name: Expansion of Brazos Medical Associates Project Address: College Station Medical Center-Med Plaza East 1602 Rock Prairie Road #3000 College Station, TX 77845 County: Brazos TENANT Name: Brazos Medical Associates Phone: 979-764AO43 Tenant Address: 1602 Rock Prairie Road #3000, College Station, Tx 77845 Contact Name: Susan Sadtler Phone: 979-7644043 Contact Address: BUILDINGIFACILITY Name: College Station Medical Center-Med Plaza East FACILITY Owner: College Station Medical Center Phone: 979-764-3412 Owner Address: 1604 Rock Prairie Road, College Station, Tx 77845 Contact Name: Frank Hartman, Dir. of Facilities Phone: — Contact Address: DESIGN FIRM Name: The Arkitex Studio Phone: 979-821-2635 Firm Address: 308 N. Bryan Avenue, Bryan, Tx 77803 Designer Name: Charles N. Burris Email: cburris@arkitex.com Type of License: Architect License Number: 7904 PROJECT DESCRIPTION Date Construction Documents Received By RAS: I0/01/2007 Start Date: 10/2007 Completion date: 01/2008 Estimated Cost: $60,000.00 Type of Work: Renovation/Alteration Does this building(s) have more than one level? Yes Are there any elevators, escalators, or platform lifts in this building? Yes Type of Funds: This project is privately funded, on private land for private use. State Lease No.: Scope of Work: Addition of two offices to an existing medical office tease space I will submit this rmation Page, Project Status Update Form and applicable fees to TDLR at P.O. Box 12157 Austin, Texts 78 1 accordance with the Texas Administrative Code Chapter 68. 00000008 10/01/2007 Signature of RAS OR Name of CP RAS/CP# Date Construction Documents Received by RAS Enter Another Project Print this Page To of f PaggITDLR_Home Pa4ejA6 Home Pagpl B Project Registration Pagg ftedback http://www.license. state.tx.us/abprojectregistration/ABProjRegFormVerification.aspx?strR... 10/3/2007 "iwNov.08 07 12: 17p C & S HEATING AND A/C 979-776-2121 p. 1 COMcheck Software Version 3.4.1 Mechanical Compliance Certificate 2006 IECC Report Date: 11/08/07 Data filename: C:\Program Files\Check\COMcheck\DR. ROBINSON.cck Section 1: Project Information Project Title: MEO CENTER Construction Site: Owner/Agent: 1602 ROCK PRAITIE RD. SUITE 3300 MED CENTER COLLEGE STATION, TX.. TX 77845 1602 ROCK PRAIRIE RD. COLLEGE STATION, TX 77845 Section 2: General Information Building Location (for weather data): College Station, Texas Climate Zone: 2a Heating Degree Days (base 65 degrees F): 1788 Cooling Degree Days (base 50 degrees F): 6851 Project Type: New Construction Section 3: Mechanical Systems List Designer/Contractor. KEY & WALSH CONSTRUCTION 232 SOUTHWEST PKWY. COLLEGE STATION, TX 77840 QypiDA Jt $yAqm Tvoe & IDercription 1 HVAC System 1: Healing: Other, Electric / Cooling: Other, Capacity <54 k8tu/h, Air -Cooled Condenser / Multiple -Zone Section 4: Requirements Checklist Requirements Specific To: HVAC System 1 : 0 1. Minimum one temperature control device per zone 0 2. Systems serving more than one zone must be VAV systems 0 3. Single -duct VAV terminals reduce primary air before reheating 0 4. Controls capable of resetting supply air temp (SAT) by 25% of SAT -room temp difference Generic Requirements: Must be met by'all systems to which the requirement is applicable: 1. Load calculations per 2001 ASHRAE Fundamentals 0 2. Plant equipment and system capacity no greater than needed to meet bads - Exception: Standby equipment automatically off when primary system Is operating - Exception: Multiple units controlled to sequence operation as a function of load D 3. Minimum one temperature control device per system 4. Minimum one humidity control device per installed humidirication/dehumidification system 0 5. Thermostatic controls has 5 degrees F deadband - Exception: Thermostats requiring manual changeover between heating and cooling O 6. Automatic Controls: Setback to 55 degrees F (heat) and 85 degrees F (cool); 7-day dock, 2-hour occupant override, 10-hour backup - Exception: Continuously operating zones - Exception: 2 kW demand or less, submit calculations 0 7. Outside -air source for ventilation; system capable of reducing OSA to required minimum Page 1 of 4 �p,Nov,y08 07 12:18p C a S HEATING AND A/C ` 979-776-2121 p.2 0 8. R5 supply and return air dud insulation•in unconditibhed'spaces R-8 supply and -return air duct insulation outside the building R-B insulation between duds and the building exterioi wFien ducts are part of a,building assembly. - Exception: Ducts located within equipment - Exception: Duds with interior and exterior temperature difference not exceeding 15•degrees F. - Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at static pressures less than 2 inches w.g. pressure classification 9. Mechanical fasteners and sealants used to connect duds and air distribution equipment 10.Ducts sealed - longitudinal seams on rigid ducts; transverse seams on all ducts; UL 181A or 181 B tapes and mastics 11.Operation and maintenance manual provided to building owner O 12.Balancing devices provided in accordance with IMC 603.15 13. Motorized, automatic shutoff dampers required on exhaust and outdoor air supply openings - Exception: Gravity dampers acceptable in buildings <3 stories, - Exception: Gravity dampers acceptable in systems with outside or exhaust air flow rates less than,300 cfm where dampers are Interlocked with fan o 14.Stair and elevator shaft vents are equipped with motorized dampers Section 5: Compliance Statement Compliance Statement The proposed mechanical design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2006 IECC requirements in COMcheck Version.3.4.1 and to comply with the mandatory requirements in the Requirements Page 2 of 4 ,.•Novy08 07 12: 18p C & S HEATING AND A/C 979-776-2121 p.3 COMcheck Software Version 3.4.1 Mechanical Requirements Description 2006 IECC Report Date: Data filename: C:1Program Files\Check\COMcheck\OR. ROBINSON.cck The following list provides more detailed descriptions of the requirements in Section 4 of the Mechanical Compliance Certificate. Requirements Specific To: HVAC System 1 : 1. Each zone of a multiple -zone system must have its own temperature control device. 2. Systems serving multiple thermostatic control zones must be variable -flow systems. Zone terminal controls must reduce the flow of primary supply air before reheating, retooling, or mixing air streams. 3. The specified multiple -zone system is equipped with single -duct VAV terminals. These terminals must be equipped with dampers, air valves, or other means to reduce the supply of primary supply air to a minimum prior to reheating. 4. Multple zone systems must include controls capable of resetting the supply air temperature by at least 25% of the difference between the design supply air temperature and the design room temperature. - Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. Design heating and cooling bads for the building must be determined using'procedures In the ASHRAE Handbook of Fundamentals or an approved equivalent calculation procedure_ 2. All equipment and systems must be sized to be no; Wiiher than needed to meet calculated loads. A single piece of equipmend providing both heating and cooling must satisfy this provision for one function with the capacity for the other function as small as possible, within available equipment options. Exception: The equipment and/or system capacity maybe greater than calculated loads for standby purposes. Standby equipment must be automatically controlled to be off when the primary equipmentandlor system Is operating. Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated load are allowed if they are provided with controls to sequence operation of the units as the load increases or decreases. 3. Each heating or cooling system serving a single zone must -have its 'own teirirperafure c or&ol'd&ioe `" 4. Each humidification system must have Its am humidity control device_ 5. Thermostats controlling both heating and cooling must be capable of maintaining a 5 degrees F deadband (a range of temperature where no heating or cooling is provided). - Exception: Deadband capability is not required i1` the themxulat does not have atrtorrratic changeover capability between heating and cooling. , . . 6. The system or zone control must be a programmable tjierincistat or other automatic control meeting the following criteria:a) capable of setting back temperature to 55 degrees F duringiheating aril setting up to 85 degrees F dxiring 000lir►gb) capable of automatically setting back or shutting down systems during unoccupied• lioriis using 7 d'ifieseiit day schedules"c) have an accessible 24wur occupant overided) liave a battery back-up capable of r iasAaurirrg progratii►nied mftigs•i& at least 1 O hours withotd power. - Exception: A setback or shutoff` control Is not required on thermostats that control systems serving areas that operate continuously. t • -, • - Exception: A setback or shutoff control is not required on systems with total energy demand of 2 kW (6,826 Bhdh) or less. 7. The system must supply outside ventilation air as required by Chapter 4 of the International Mechanical Code. If the ventilation system is designed to supply outdoor -air quantities:exoeedbong minimum. required.levels. th%aystern must be capable of reducing outdoor -air flow to the minimum required levels. ,, S. Air ducts must be insulated to the following levelsa) Supply and return air duds for conditioned air located in urwo mditioned spaces (spaces neither heated nor cooled) must be insulated with a mirrimum of R-5 Unogn Gorre[�:spaoes.ineinrde allies, crawl spaces, unheated 6aselnents, and unheated garages.b) Supply arld TWm. air ductsand,plenums must be insulated to a minimum of R 8 when located outside the buitding.c) When duds are located within exterior components (e.g., floors or roofs), minimum R-8 insulation is required only between the dud and the building exterior. - Exception: Dud insulation is not required on ducts located within equipment-:. - Exception: Dud insulation is not required when the design temperature difference between the interior and exterior of the duct or plenum does not exceed 15 degrees F. I - • . - Exception: Continuously welded and kx*kxj4ype longitudinal joints and seams on duds operating at static pressures less than 2 inches w.g. pressure classification. Page 3 of 4 ,,Nov,-08 07 12:18p C & S HEATING AND A/C 979-776-2121 p.4 9. Mechanical fasteners and seals, mastics, or gaskets must be used when connecting duds to fans and other air distribution equipment, including multiple -zone terminal units. 10. All joints, longitudinal and transverse seams, and connections in ductwork must be securely sealed using weldments; mechanical fasteners with seals, gaskets, or mastics; mesh and mastic sealing systems; or tapes. Tapes and mastics must be listed and labeled in accordance with UL 181A and shall be marked '181A-P for pressure sensitive tape;181A-M' for mastic or'181A-H' for heat -sensitive tape. Tapes and mastics used to seal flexible air ductsand flexible air connectors shall comply with UL 181 B and shall be marked '181 B-FXfor pressure sensitive tape or'181 B-M' for mastic. Unlisted dud tape is not permitted as a sealant on any metal ducts. 11. Operation and maintenance documentation must be provided to the owner that includes at least the following information:a) equipment capacity (input and output) and required maintenance actonsb) equipment operation and maintenance manualsc) HVAC system control maintenance and calibration information, mduding wiring diagrams, schematics, and control sequence descriptions; desired or freW-detemrined set points must be permanently recorded on control drawings. at control devices, or, for digital control systems, in programming commented) complete narrative of tow each system is lotended to operate. 12. Each supply air outlet or diffuser and each zone terminal device (such as VAV or mb&q box) must have itt own balancing device. Acceptable balancing devices mdude adjustable dampers located within the ductwork, terminal devices, and supply air diffusers. 13. Outdoor as supply and exhaust systems must have motorized dampers that automatically shut when the systems or spaces served are not in use. Dampers must be capable of automatically shutting off during pm4x=uparwy bu'ridhV warm-up, cooEdown, and setback, except when ventilation reduces energy costs (e-g., night purge) or when ventilation must be supplied lameet code requirements- Both outdoor air supply and exhaust air dampers must have a maximum leakage rate of 3 ckWft2 at 1.0 in w.g. when tested in accordance with AMCA Standard 500. - Exception: Gravity (non -motorized) dampers are acceptable in buildings less than three stories in freight - Exception: Systems with a design outside air intake or exhaust capacity of 3OG dm (M Lls) or less that are equipped with motor operated dampers that open and close when the unit is energized and de�energ¢ed, respectively. 14. Stair and ekwabor shaft vents must be equipped with motorized dampers capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke defection systems. AS gravity outdoor a= supply and exhaust hoods, vests, and ventilators must be equipped VMh motorized dampers Mrat wi au6wrailically shut when One spaces served are not in use. Excxplions: - Gravity (non -motorized) dampers are acceptable in buildings less than three stories in height above grade. - Ventilation systems serving unconditioned spaces. v COMcheck Software Version 3.4.1 Lighting Compliance Certificate e8/1 . 2003 IECC Report Date: 11/01/07 Data filename: S:\_14 ACTIVE T&M\TM 1400 KEYS AND WALSH\TM1410 BRAZOS MED. ASSOC\BMA Compliance Survey.cck Section 1: Project Information Project Title: Brazos Medical Associates Construction Site: Owner/Agent: Rock Prarie Road College Station Texas, TX 77840 Section 2: General Information Building Use Description by: Activity Type Project Type: New Construction Activity Type(s) Floor Area Medical and Clinical Care 1870 Section 3: Requirements Checklist Interior Lighting: 62/1. Total actual watts must be less than or equal to total allowed watts. Allowed Watts Actual Watts Complies 2244 1938 YES 2(2. Exit signs 5 Watts or less per side. Exterior Lighting: Lj 3. Efficacy greater than 45 lumens/W. Exceptions: Designer/Contractor: Specialized lighting highlighting features of historic buildings; signage; safety or security lighting; low -voltage landscape lighting. Controls, Switching, and Wiring: [g 4. Independent controls for each space (switch/occupancy sensor). Exceptions: Areas designated as security or emergency areas that must be continuously illuminated. Lighting in stairways or corridors that are elements of the means of egress. 5. Master switch at entry to hotel/motel guest room. 6. Individual dwelling units separately metered. 7. Each space provided with a manual control to provide uniform light reduction by at least 50%. Exceptions: Only one luminaire in space; An occupant -sensing device controls the area; The area is a corridor, storeroom, restroom, public lobby or guest room; Areas that use less than 0.6 Watts/sq.ft. 8. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions: Page 1 of 3 Areas with only one luminaire, corridors, storerooms, restrooms, or public lobbies. 9. Photocell/astronomical time switch on exterior lights. Exceptions: Lighting intended for 24 hour use. o 10.Tandem wired one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts). Exceptions: Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 4: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2003 IECC, Chapter S, requirements in COMcheck Version 3.4.1 and to comply with the ma dat requirements in the Requirements Checklist. PM (l. / . O Name - Title Si a ure Date 7- Page 2 of I LrJ COMcheck Software Version 3.4.1 Lighting Application Worksheet 2003 IECC Report Date: Data filename: S:\_14 ACTIVE T&M\TM 1400 KEYS AND WALSH\TM1410 BRAZOS MED. ASSOC\BMA Compliance Survey.cck Section 1: Allowed Lighting Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B x C) Medical and Clinical Care 1870 1.2 2244 Section 2: Actual Lighting Power Calculation A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Total Allowed Watts = 2244 B C D E Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Medical and Clinical Care (1870 sq.ft.) Linear Fluorescent 1: 48" T8 32W (Super T8) / Electronic 2 25 64 1600 Compact Fluorescent 1: Twin Tube 24/26/27W / Electronic 1 13 26 338 Total Actual Watts = 1938 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 2244 Total Actual Watts = 1938 Project Compliance = 306 Page 3 of 3