Loading...
HomeMy WebLinkAboutRES2007-03287, 07-3288i WF0983848 / 001 City of College Station . . to PAGE 1 REQ. DATE: 11/27/07 11/27/07 9:29:33 LOCATION: 205 FIELDSTONE PL LOC ID: 209870 REQUESTOR: STYLECRFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 11/27/07 SCHED COMPLETION: 11/27/07 ******************************************************************************** JOB ORDER RESULT COMMENTS r PREPARED 4/17/08, 8:03:44 INSPECTION TICKET PAGE 8 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/16/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 205 FIELDSTONE PL SUBDIV: SONOMA PH 1 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 578700-0110-0220 APPL NUMBER: 07-00003287 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/03/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 12/03/07 AP November 30, 2007 11:49:17 AM glsouth. MONDAY AM Strings On Setbacks O.K. Slab Ground Installed B115 01 1/04/08 RH BLDG, FRAMING TIME: 17:00 1/04/08 DP January 4, 2008 10:51:19 AM acarter. O1/04/2008 03:24 PM RH PDA Need proper APA nailing pattern. B115 02 1/07/08 RH BLDG, FRAMING TIME: 17:00 1/07/08 AP January 7, 2008 10:44:55 AM kwolfe. B130 01 1/09/08 RH BLDG, INSULATION TIME: 17:00 1/09/08 AP January 8, 2008 1:56:52 PM kwolfe. B125 01 4/16/08 B I BLDG, FINAL TIME: 17:00 i April 16, 2008 1:15:46 PM npadilla. -------------------------------------- COMMENTS AND NOTES ------ 0&------------------- i _ . From:STYLECRAFT BUILDERS INC 979 690 0348 01/17/2008 14:35 H393 P.008/010 . Oq - 301r7 Renewable 5 Year Subterranean Termite Retreatment Agreement (Does not cover any other species of Termites) "Shielding & Protecting Homes Against Pests" This agreement provides for retreatment only of the infested areas covered under the original treatment areas (See Graph). / —6111) Customer Name Date Billing Name if different Street Address of treated structure t 7j< Y� City State Zip Code Home Phone Work Phone Type of Treatment Partial Bait !Pre -Treat Treatment for." Prevention Control of Subterranean Termites Billing Address if different City State Zip Code Initial Termite Cost $e%. Additional Renewals Paid.r Other — Tag Casb_Check# Total $--���— Payment $�_ Balance $ Credit Card: Type Exp. Date Card Number 5 Year Subterranean Termite Retreatment GuarantM, RP Lee Termite and Pest Control will retreat the structure for Subterranean Termites at no cost to the customer, if an infestation of Subterranean Termites is found, as long as the original treatment is paid in full and the customer is current on their yearly renewals. This Agreement will expire in one (1) year unless the customer elects to pay the yearly warranty fee. The guarantee can be renewed for up to five (5) years by paying the yearly warranty fee. RP Lee Termite and Pest Control may approve additional warranty years after -the five (5) yearn with an additional increase in the yearly warranty fee. The guarantee does not cover any damages to the structure or contents of the customer The customer agrees to control all condusive conditions that may cause reinfestation. If the structure is modified, added on to, altered, or if the soil treatment around the structure is removed the customer must contact RP Lee Termite and Pest Control and pay for additional treatment in order to keep the guarantee in effect If the customer does not pay for additional treatment the retreatment guarantee can be cancelled_ ,renewal Fee: Customer may elect to renew the retreatment guarantee for additional years. The renewal fee is $ plus tax_ The renewal fee is due on or before the annual anniversary date or paid $ plus tax every third (3) month with imypction. arc mug a uaran : e customer agrees to correct a 1 con usive nditions, at owner's expense, as they exist or as they occur in the future in order for the guarantee not to be cancelled. Customer will make the structure available for inspections and treatments as requested by RP Lee Termite and Pest Control. Reinspection: RP Lee Termite and Pest Control will reinspect the structure at customers request or any other times RP Lee Termite and Pest Control deems necessary. RP Lee Termite and Pest Control recommends that the customer call and set up an annual inspec- tion at the time of customers yearly renewal. 'Transfer.This agreement may be transferred to a new owner with the payment of a transfer fee of $ / , copy of the Wood Destroying Insect Report from the sell, and approval of RP Lee Termite and Pest Control. This -Subterranean Termite Retreatment Guarantee dots not prevent and is not intended to control other forms of Termites 013mood Formosan etc 1. Wood Boring Beetles CarpenterAnts Carpenter Bees. Wood Rot Fungus- Decay or any other wood destroying inserts or organisms. Arbitration: In the event of any dispute arising out of this agreement or any other services performed or not performed the parties above agree to participate in mediation through and in accordance with the commercial mediation rules of the American Arbitration Association. The Arbitrator shall consider the legal defenses raised in the arbitration, and the decision of the arbitrator shall be final, binding, non -appealable and may be entered and enforced in any court having jurisdiction in accordance with the Federal Arbitration Act Limitation of Liability: Landscaping and grass next to the slab may be damaged during treatment, carpet may need to be pulled up in certain areas around the home, drill holes may need to be made in floor coverings such as tile or linoleum or in cabinets next to pipe areas, and holes may need to be cut in walls. Customer agrees not to hold RP Lee Termite and Pest Control liable for these damages, or treatment techniques, or other damages that may occur during treatment Agreement: This Agreement shall be the entire agreement between customer and RP LeeTermite and Pest Control. If any part of this agreement is found to be invalid it shall not affect the validity of arty other part of the Agreement. We are licensed by the Structural Pest Control Board - 333-Gundalun&. Swig 1-530 Austin, 3[% 78701 512-305-8250 RP Lee Termite Pest Control Cert. Apl.# customer ignature Date From:STYLECRAFT BUILDERS INC 979 690 0348 01/17/2008 14:35 #393 P.009/010 SUBTERRANEAN TERMITE PRE -CONSTRUCTION TREATMENT DISCLOSURE FOR EACH ESTIMATI Licensed and regulated under the Texas Structural Pest Control RP LEE TERMITE & PEST CONTROL PO Box 9423 College Station, TX 77842 • 072) 690-8622 • TPCL #11486 - CUSTOMER INFO TIO� Name: YZ ea. Phone #1: Phone #2: Address: City: State: Zip Code: Location to be Treated: �.7 r F C� Tj a'� el. S . ;if 77' o J - For all treatments there will be a diagram showing exactly what will be treated priorto the beginning of treatment Review the Pesticide LI l provided to you at this time for minimum treatmentstandal Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the law. Review the consumer information sheet for further information. If have any questions, contact the pest control comoany or the Texas Structural Pest Control Board, P.O. Box 1927. Austin, TX 78767-1927. Telephone number (512) 305-8250. Before conducting a termite premnstruction treatment, the company snfill present a complete diagram of the structure including construction details. When construction prevents performance of a treatment, in accordance with a bid for full treatment, any change to a partial treatment by the company providing the treatment Will be permitted if the owner of the structure or the person in dtarg( the construction and the certified applicator for the pest control company sign a statement attesting to the construction conditions. The agreement must be attached to the contract with an amen( diagram showing the exact areas to be treated. Copies must be sent to the owner of the property within seven days of the application. M'p� Diagram HIMU off Structure(s) in and ME= Proposed Area(s) To Be Treated 11111121111111111111 ■■■.MEMEM ■!!h!`.-:■■�.11■r��ii.la■■■■■■■i■ '■i■::ii'1.'.�■ am W ■■■■■■■■■■■■U■■■■■■!■■■■.■■■Il■.■■■■■■.■!■■■W■■■■■ ■■ ■!■■ OOm ■■■ AN= ■@!■■!.i■■■■�■■1..■! ■■■� �■■�■■O■■■C■■!1■0■■■f Uri■■■■■■■!■■ manvo m■■■ viEam ...■.■ ■■■■■m■.ME ■■�.;■'■s■■ m■ m■■■■O■1 ■■!■1■.■■■ ■■■■■■■li■■!■!■.■1■■■ ■>t■!■■■ia CC lr..■!:3■,■��..■''�CC!"!'.v:CC:�'.�'■I�CC:�CC:'t:■':'■:■� u■ mom rung "�>t�ii '■:iC■"■■■■ .n ��1.!■■sm!■■lmE •�s i ■■lliCivamm■■■■■■■■■! MOM LWA2WiL.■■C:/f:■■l2 ■.p.■�.1 !! 11111M■ gi■■■ii■■i■■■■' Qi!:Ci■'CC'�iiaso ■iC■m/. _W m�■i�i'■■C■ii ■M■■■■i1■'■■■■■■1�■.■■I�■■■u1�0!■�/■■..■� ■■■n■■■n ...■.■a■■■■m■■■.■■■�■■■■r■,!h...��..�.� ■■mtll■■■!!Om■Q■■ MOM ! ! ■■■1■■■■■■■■.■■■■.■r>■■1■! ■i■■■.■I•�■■■■■IN■■■!■ti■MO.! ■■mm■■■■■■■■■■■!m■a�m■min mtillmtl(wm■■ .■■. ■O■■■.;tll1 ■lmmmm ■ a■■■■■■■■ ■■!/■■■O■m■■■■1■m ■■■■■■f m■�p ■■MO"=O -no ■■■m■■IA■■m■■■■■■!■■p■■m/.■ .lnl•�miil■■■:"wm■■.■!■■■■ E■!■n■H■■■■n■■■■O.■■■m■■. la; ■■MMIN ■■!m!m ■■amos■m.lf■tl■>�■.orE■;a Samoa ■■ma■>t.® .m a mint...■■ME MENEM .m■■!■■.....■�■�1/�r ■■■....m■v■■■m!■■■■.,!■■.■■.HmS■■ m om»•�� +��11im. ■■■■ m■m■mmm■■■m■■!m■■■!■■■■■■m IMEN■■■'C:y'■'u"■oiui■miinw■■■m■■ .'■miffEN ffuu'■)t■ notes: &09CAfe �7, 6t/yae) 2 ( ow,— T r s1,05 ;g De 4:1.-Towei-TI Type of treatment proposed: (check all that apply): ❑ Full Partial *OVVood ❑ Bait ❑ Commercial CICSingle Family Total square feet to be treated: _ Total linear feet to be treated: Approximate measurements of structure(s) to be treated: el'01 F A label of fg E1dA P'410e tenniticide(s) is attached. The percentage of the termiticide(s) to be applied at this location is %. Estimated amount of termiticide to be applied: r gallon(s). THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREALTMEN r-BUILDERS GUIDE IS ATTACHED ON BACK (SPCE113 4) THE BOARD APPROVED SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUCTION TREATMENT SERVICE. Complete details of warranty (if any) including time period of warrant)4 renewal options and cost, and obligations of the contracting parties is attached. If the warranty does not include the entire structure treated, the areas included in the warranty are (specify): 4- A consum 'nfornation sheet is also attached. le -Y.1011eel Signature of CA or chniaan Printed Name Date Signature ofMtomer Verifying Receipt of This Document Date 11Htsslrn340-2.• otmaor white Copy - ServicePmvider YenowCopy -Customer Fur od9W ad Fiitee by ScrvfootgM Coanv—ems t-MWs24M.Oedb. TX caw; Service Treatment Invoice Route: 6 Map Code:. Start Time: m/pm Finish Time: ---am pm Type of Service: f` itial Regular Follow Up One Time Charity Service Address Name: Address: City: (I � TX Phone: Billing: iEE "Shlelding & Protecting Homes Against Postal' TPCL #11486 Date: r �'" ?U�/ Appoiut.Timc: Ir am/pm Frequency: � BM Q S Y Structure: labs Crawl P/B Combo Pets: Dog(s) Cat(s) Bird(s) Fish A./4. Cost of Service $ cue.?. TAX. $ Total Due $ 1,7-0 Payment $ Balance It - ,7FU - PEST PROBLEMS: d- DIRECTIONS / INSTRUCTIONS: EQUIP. METH. LOCATIONS) PRODUCT WOOD DESTROYING INSECTS GENERAL PESTS I FLEAS i MFCE RODENTS AT MONITOR OTHER QTY TARGET PEST(S) Payment by: Cash ❑ Check ❑ # Credit Card ❑ PAYMENT DUE UPON RECEIPT Termidor SC-Fipronll .06% Termidor BOW Fipronll Subterranean Termites, Ants Size of Tanis . Posted .06% Hole-careDlsodlum OMaborete'Ibtrahydate 50% Subterranean Termites. Size of Tank Posted Su bterranean/Fottnosan/Drywood Tiermtles, Carpenter Ants, Beetles, Posted ._• 4: Invader HPH-Baygon 1% Carpenter Ants, Spiders, Crickets, Millipedes, Beetles, Termites. Demon WP-Cyaho•Phenoxyphegyl Cockroaches, Millipedes, Sowbugs, Flies, Ticks, Mosquitos, Plllbugs, Dlmethycyleyclopropan¢carbozytate 1% Tempo Ultra WP-Cyfiuthrin .02$% (Rest) Silverfish, Bees, Ants, Carpenter Ants, Scorpions, Spiders. (gen. surface spray, spot, mist, crack & crevice) Ants (Except Pharaoh), Cockroaches, Crickets, Earwigs, Millipedes, Flies, Fruit Flies, Beetles, Plllbugs, Silverfisb, Spiders, Gnats, Hornets, Wasps, Yellow Jackets. Telster EZ Blfenthrin .2% Maxforce-Hydramethylon 1%-2ti1S% Ants, Centipedes, Cockroaches, Crickets, Grasshoppers, Scorplonsjlcks, Silverfish, Spiders. Cykick CS Cyttuthrin PharachAots, Crickets, Carpenter Ants, Lg. Roaches, Variety of Ants. .05% Phantom Spiders, Scorpions,Ants, CarpenterAats, Carpenter Bees, Roaches, Crickets, Silverfish. .5% Pbaroh Ants, Varlety of Ants, Roaches. Tengard-Permethrin .5% Fleas, Ticks, Ants, Centipedes, Carpenter Ants, Bees, Wasps, Carpenter Bees, Cockroaches, Crickets, Flies, Earwigs, Millipedes, Beetles, Plllbugs. Suspend MethySC-Deletnox rin %4.(R5 ST) Fleas, Bees, Beetles, Roaches, Crickets, Lice, Flies, Scorpions, Ticks, Wasps. NygueR Pyrekyletn05 10% (R 9T) IGR-Growth Regulator-Flens, Roaches, Crickets, Flying Insects, Stored Product Pests. Excite R Pyrethrin .OS% Fleas. Fastrac-Bromethalln .01% Mice, Rodents, Rats. Bait Station-Large/Small Glue Boards Mice, Rodents, Rats, Bug Monitors. Speckoz-Pyrocide .50% Houseflies, Mosquitos, Moths, Flens, Wasps, Hornets, Ticks, Cockroaches. Blfen I/T Blfenthrin .06% Splders,Auts, Roaches, Silverfish, Earwigs, Fleas, Scorpions Mitipment: A -Compressed Sprayer P-Power Sprayer B-Bait Dispenser BS-Bait Station BVBait Tiap D-Aerosol Can G-Glue Board H-Hand Duster S-Spreader F-Fogger FM-Foamer AC-Actisol unit Other Locations: 1-Kitchen 2-Bath(s) 3-Bedrooms 4-Dining Room 5-Utility 6-Storage 7-Common Areas 8�Galage 9-Perimeterof Structure 10-Attic I1-Yard 12-Under Home 13-Warehouse 14.Office 15-Exposed Wood 2' up from Slab Other Method of Treatments: CC -Crack & Crevice SS -Sub -Slab Injection VT -Void Treatment BP -Bait Placement BS-Broadcast Spray PB-Perimeter Barrier BV-Brick Venire WT-Wood Treatment PRECAUTIONS: Do not touch treated areas till dry. Do not tampet with bait stations. Ventilate rooms after treatment. Keep pets away until pesticides have dried. Licenced by the Structural Pest Control Board - 333 Guadalupe, Suite I-530 • Austin, TX 78701.512-305-8250 SERVICE TECHNICIAN:. �� � = �- CUSTOMER SIGNATURE: _ l�i� a�%�''''� t%�.. ��ff DATE: •/�"�%-�% O R C/) r M C-D n 00 C 0 M Cn z CD v cD co CZ) CZ) CA) A Co W O v N C7 CZ) co .A W O7 CD CIO 0 CD CZ> CD From:STYLECRAFT BUILDERS INC 979 690 0348 01/09/2008 09:44 #193 iPOf/OA t'S;�7 U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE OMB No. 1660-0008 Federal Emergency Management Agency I Expires February 28, 2009 National Flood Insurance Program Important: Read the instructions on pages 14 SECTION A - PROPERTY INFORMATION le �. o N, ' �'- e'`C�k 1' Al. Building Owner's Name S lecraft Builders A2. Building Street Address (Including Apt., Unit, Suite, and/or Bldg. No:) or P.O. Route and Box No. 205•Fieldstone Place r vp yi9�,YY e; �21 �I �i3 ' „ Ei "i" f n�fWeii. v oldie ZIP Code College Station Texas 77M A3.. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Sonoma, Phase 1, Block 1, Lot 22 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5. Latftude/Longftuds: Lat. N 30deg 33.390 Long. W 96deg 17.420 Horizontal Datum: ❑ NAD 1927 NAD 1983 A6. Attach at least 2 photographs of the building If the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1 l s A8. For a building with a crawpace r enclosure(s), provide: : A9. For a building with an attached garage, provide: a) Square footage of crawl spat or enclosure(s) sq ft a) Square footage of attached garage sq ft b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage enclosure(s) walls within 1.0 foot above adjacent grade walls within 1.0 foot above adjacent grade c) Total net area of flood openings in A8.b sq In c) Total net area of flood openings in A9.b sq In SECTION B - FLOOD INSURANCE RATE -MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number 62. County Name B3. State Cityof Bryan 480082 Brazos Texas B4. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone Date Effective/Revised Date Zones) AO, use base flood depth) 48041CO205 D 7-2-92 2-9-2000 AE 321 tito. inaicate me source of the Base Flood Elevation (BFE) data.or base flood depth entered in Item B9. ❑ FIS Profile FIRM []Community Determined ❑ Other (Describe) B11. Indicate elevation datum used for BFE In Item B9: ❑ NGVD 1929 ❑ NAVD 1988 nOther (Describe) local B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes No Designation Date ❑ CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings* O' Building Under Construction' ❑ Finished Construction 'A new Elevation Certificate will be.required when construction of the building is complete. C2. Elevations —Zones Al-A3.0, AE, AH, A (with BFE), VE, VI-V30, V (with BFE), AR, AR/A, AR/AE; AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-g below according to the building diagram specified in Item A7. Benchmark Utilized Subdivision BM Vertical Datum Conversion/Comments .Property is not in the FEMA 1 % or 100 year floodpl in, but the City of College Station requires a MFF 322 ft for stormwater Check the measurement used. a) Top of bottom floor (including basement, crawl space, or enclosure floor) 322.00_0 feet ❑ meters (Puerto Rico only) b) Top of the next higher floor c) Bottom of the lowest horizontal structural member (V Zones only) d) Attached garage (top of slab) e) Lowest elevation of machinery.or equipment servicing the building (Describe type of equipment in Comments) f) Lowest adjacent (finished) grade (LAG) g) Highest adjacent (finished) grade (HAG) ❑ feet feet _❑ feet _ ❑ feet 321.07 feet 12A.38_0: feet ❑ meters (Puerto Rico only) ❑ meters (Puerto Rico only) ❑ meters (Puerto Rico only) ❑ meters (Puerto Rico only) ❑ meters (Puerto Rico only) ❑ meters (Puerto Rico only) SECTION D-SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify ele% information. l certify that the Information an this Cerftate represents my best efforts to interpret the data available: 1 understand that any false statement may be punishable!by fine or impnisonmeht under 18 U. S: Code, Section 1001. ❑ Check here if comments are provided on back of form. Title ;F ,t License Number' 5743 o� State ZIP Code Texas T7803 Telephone ,3*� :979-779-7670 FEMA Form.81-31, February 2006 See reverse side for continuation. Replaces all previous editions From:STYLECRAFT BUILDERS INC 979 690 0348 01/09/2008 09:44 #193 P.002/003 Building Photographs See Instructions for Item A6. Building Street Address (including Apt, Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number ZIP Station If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identify, all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page, following. Finish Floor Elevation High Elevation From:STYLECRAFT BUILDERS INC 979 690 0348 01/09/2008 09:45 #193 P.003/003 Building Photographs Continuation Page Building Street Address (including Apt, Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number If submitting more photographs than will fit on the preceding page, affm the additional photographs below. Identify all photographs with: date taken; "Front View' and "Rear View"; and, if required, "Right Side View" and "Left Side View." Low Elevation May.30, 2008 8:43AM Stylecraft Builders, Inc. No.1225 P. 2 Mats bu ud u'I :J4a Pau i w 1 1 1 i ams Lana Survey 9797797G72 Iva 3 ;s? U:. CrEPARTMENT OF HOMELAND secuRr Y . CLG V A I 1 VIV %wr.M I I ri%o '► I C Exoir bruit v 28 Federal Emergency Management Agency Exnir®s Febtvary 28.2009 National Flood Inswance Program Important: Read the instructions on pages 1-8. SECTION A- PROPERTY INFORMATION ForIirstinceiiti>ise= ` 9 Name Al. Building Owner' Aaron Boswell and Theresa Boswell A2. Sunding StreetAddreea (including Apt., unit, sutlo, and/or Bldg. No.) or P.O. Route and Sox No. CarTit aTl �FififC fitli ter!' � •" _ 2W Fleldatane Place city Stan® ZIP Code - coir a Statron Texas 77845 A3. Property Dsscdpllon (Lot and Block Numbers, Tax Parcel Number, Legal Descrlplion, etc,) Sonoma, Phase 1, Block 1, Lot 22 A4. Bddfng Use (e g.. Residential, Non-Resldentlal, Addttlon, AvAmory; etc.) Residential A5. LatlturWLongkWe: Lat. N 30deg 33.390 Long. W 96deg 17.420 Horizontal Datum: ❑ NAD 1927 NAD 1983 A$. Attach at lust 2 photographa of the building if the Certificate Is. being used to obtain flood Insurance. A7, Building Diagram Number 1_ A& For a building with a crawl space or enclosure(s), provide: Ag. For a building with an attached garage, provide: a) Square footage of crawl space or enclosures) sq ft a) Square footage of attached garage _ .. _ _ _ sq ft b) No. of permanent flood openings In the crawl space or b) No. of permanent flood openings In the attached garage enclosure(s) walls wlth In 1.0 foot above adjacent grade walls within 1.0 foot above adjawd grade c) Total not area of flood openings in AS.b sq In c) Total net area of Stood openings In A9.b sq in SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION 81. NFIP Community Name A Community Number B2. County Name TW8tate Oy of College Station 480083 Brazos Texas 154, Map/PaW Number 95. Suffix B6. FIRM Index B7, FIRM Panel 58. Flood 59. am@ Flood FJevation(s) (zone Date Effective/Revised Date Zones) AO, use base flood depth) 48041CO205 D 7•$•92 2-9-2000 AH . 321 910. Indlcals the source of the Base Flood Elevation (BFM data or base flood depth entered In Rem B9. ❑ FIS Profile FIRM ❑ Community Determined ❑ Other (Describe) 811. Indicate elevation daturn used for BFE in hem Be: ❑ NGVD IM ❑ NAVD 1988 Mother (Descrlba) local 812- Is the building located in a Coastal Barrier Resources System (CSAa) area ar Otherwise Protected Area (OPA)? ❑ Yes 0 No Designation Date ❑ CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SUAVV RMUIRL:D) Cl. Building elevations are based on, ❑ Construction Drawings' ❑ Building Under Conshvetion' Finished Construction A new Oevabon Certificate will be required when construction of the building is complete. C2. 'Etavadons —Zones Ai-A30, AE, AK A (with BFq, vE, VI-V30, V left SM, AR, ARIA, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items 02.a•g below according to the building diagram specified In Item A7. Benchmark UGlizad Subdivision BM Vertical Datum Converskin/Oamments Property is not 1n the FIEMA 1 % or 100 year floodplain, but the City of Co@egs Station requires a MIFF 322 R for stonnwater _ Check the measurement used. a) Top of bottom floor (including basement, crawl space, or enclosure floor) b) Top of the next higher floor c) Bottom of the (owest hoti2onml structural member (V Zones only] d) Attached garage (top of slab) a) Lowest elevation of machinery or equipment servicing the buikflng (Describe type of equipment In Comments) f) Lowest adjacent (finished) grade (LAG) g) Highest adjacent (finished) grade (HAG) =68 , feet feet lost _❑ feet _❑ foot meters (Puerto Rico only) meters (Puerto Rico only) meters (Puerto Rico only) ❑ meters (Puerto Rico on)y) ❑ meters (Puerto Rico only) feet ❑ meters (Puerto Film only) M25 feet ❑ meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This rerttficattan Is to be signed and Sealed Dy a lama Surveyor, engineer, or arcnitect aumormw oy law to cerary ale information, / cerW that the InlonnoWn an Mis Cdifflh a reprrea" my best efforts to intemml the lotto avaHW& I understand Mat any false statement maybe punishable by fine or frtip6sonmerrt tinder 18 U.S. Code Sedan 1001 0 Check here if comments are provided on back of fort. FEMA Form al-31, February 2008 See reverse side for continuation. Replaces all previous editions Ma May.30. f-.'3,�$:44aMPaul 1irlfamS 1Bann' Iurve 9797797672 No. 1225 P, 4 J y p• Building Photographs Corttinuatlon Page For Insurance Company Us4 Build9ng Street Addrm (Indudino Apt., Una, Suite, arWor Eodg. No.) or P.O. Fkoute and Box No. Polley Number 205 Fieldstone Place Gay State ZIP code company tJAEc NurMw -1- If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and 'Rear View"; and, if required, "Right Side Vleve and `Leff Side View." Low Elevation May,30. 2008:44aM S t y I e c r a f t Builders, Inc, Mai :%U un ur:14a Paul W1111ams Lana survey 9797797672 No.1225 F. 4- p. a Building Photographs AAA inntnirtiAnS fnr item AS. For Insurance Company Usa: Building street Address (including Apt, Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Poky Numtw 2D5 Fleldstone place City State ZJP Code cotr�aany �u nwrwer Calve Station Texas n If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identify all photographs with: date taken; "Front View" and "Rear View"; and, If requirad, "Right Side View" and °Left Side View." if submitting more photographs than will fit on this page, use the Contlnuatlon Page, following. Finish Floor Elevation High Elevation (5/5/2008) Gina Southerland Re: Calling for CO for 205 Fieldstone PI .. � Page 11 From: Joe Garcia To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Kim W... Date: 4/18/2008 4:19 PM Subject: Re: Calling for CO for 205 Fieldstone PI NO FOR CO. SEWER BOX IS BURIED. JMG >>> Amber Carter 04/17/08 1:42 PM >>> by 07-3287 Any issues? I/2- DIA. SMOOTH DOWEL 2'-0- LONG W/ PVC CAP - PLACE IN $lA8 OR DRILL 9' INTO EXISTING GRADE BEAM. TAPE CAP TO LEAVE TOOL EDGE E.J.T. 1' ® END OF ROD 4' THICK PAVING 3000 PSI REINF. W/ 83's ® 18' O.C.E.W. MID DEPTH USE CHAIR SUPPORTS DISCONTINUE REINF. O E.J. 1x REDWOOD DIVIDER D SECTION "D" N.T1 CONTINUE REINFORCEMENT THROUGH KEYWAY ONE CHAIR PER 4' THICK PAVING 3000 PSI 4 SO. FT. MIN. REINF. W/ 13's ® 18' O.C.E.W. MID DEPTH USE CHAIR SUPPORTS C SECTION "C" N.rs. 3/8- DIA. DOWEL W/ SLEEVE. DRILL INTO EXISTING SIDEWALK Ix REDWOOD = B SECTION T" N.TS �DRILLINTO -W/ SLEEVE. G CURB 8' X 8'BEAM W/ 4 �5 REBAR A SECTION "A" N.T3. d < d �— d ° INSTALL EXPANSION JOINT ° 0 MID -DRIVE IF OVER 45' PR 4'REINIFORCEOPSI CONC. 6 S 18W//%3O.C.E.W. OF I SIDEWFY ALKI� CITY SIDE WALK IN FIELD MAI L LAYDOWN CURB DETAILS Q c d CONTRACTION JOINT WHEN DRIVE G 16 WIDE 4" THICK 300q PSI CONC REINFORCE W/ #3 BARS ® 18" O.C.E. CONTRACTION JOINT E PTALL JOINT3/ METAL KEYWAY $'ADIA. SLICK DWLS. 0 18 O.C. W/ SLEEVES ONE SIDE WATER VALVE COVERS 205 FIELD STONE PL SONOMA PHASE- 011 BLOCK- 011 LOT- 22 .0 T7 0 C3 0. L O 0Io,E N v m C V C 0 3ru_v v CNL, �= ON N cina u o �n o,o• .T UO v On v vVL, JOB#: 07173 J Z O U F- LLJ V) w Li- Ln CD CV PRE -CON CREATED: 11/7 PRE -CON: REVISED: ISSUED: PRINTED: 1 1 /7 Q 00 v- w � M d' r-- H SCALE: - 1 •-2a C-1 BUILDING PERMIT CITY OF COLLEGE STATION 1101.,TEXA18 AVENUE, COLLEGE STATION, TX 7784a PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00003287 382096 205 FIELDSTONE PL 578700-0110-0220 Date 11/26/07 RESIDENTIAL, 1 UNIT DETACHED NEW SONOMA PH 1 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 95238 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID DUE FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1443.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 427.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 536953 Permit Fee . . . . 444.00 Plan Check Fee .00 Issue Date . . . . 11/26/07 Valuation . . 95238 Expiration Date . . 5/24/08 Qty Unit Charge Per Extension BASE FEE 260.00 46.00 4.0000 THOU BLDG, VAL 50001-100000 184.00 ---------------------------------------------------------------------------- Special Notes and Comments -Minimum Finished Floor of 322' for F ood Management, Elevation Certificate - - Ap -----requires ---------------------------- BUILDING DEPT RE$R7SENTATIVF,:, -- ----------------------- APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101,TEXAS AVENUE, COLLEGE STATION, TX 7784C PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00003287 Application pin number . . . 382096 Page 2 Date 11/26/07 Special Notes and Comments -Narrow Wall Bracing Fully Sheathed with 16" minimum APA Garage Framing ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 301-) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/O ACCESS MAY HAVE TO --------------------------------------------- ----ij-;PaA; ---------- BUILDING DEPT REP SE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101,TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov --------------------------------------------=------------------------------- Page 3 Application Number . . . . . 07-00003287 Date 11/26/07 Application pin number . . . 382096 ---------------------------------------------------------------------------- Special Notes and Comments BE ELEVATED TO ALLOW FOR ATTIC INSULATION ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER'PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. -- ------------------------------------------------f'�.i•-- - ------------ BUILDING DEPT REPRESTIVE:_ APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101.TEXAS AVENUE, COLLEGE STATION, TX 77840- PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00003287 Application pin number . . . 382096 Page 4 Date 11/26/07 Special Notes and Comments SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 2001 A .40 OR LOWER FACTOR AND ABOVE 200 TO 30% A .35 FACTO OR LOWER SHALL BE MET. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ELEVATION CERTIFICATE REQUIRED - PROVIDE ELEVATION CERTIFICATE PRIOR TO SLAB INSPECTION AND A SECOND CERTIFICATE PRIOR TO FINAL INSPECTION/C.O. Other Fees SEWER TAR 4" BUILDING DEPT REPRES 4LTIVE: APPLICANT: 350.00 BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840- PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 07-00003287 Date 11/26/07 Application pin number . . . 382096 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged --------------------------- Paid Credited -------------------- Due ---------- Permit Fee Total 444.00 444.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1194.00 1194.00 .00 .00 44A;� `--------------------------------------------------------- BUILDING DEPT REPRES TA I . APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00003288 525504 205 FIELDSTONE PL 578700-0110-0220 Date 11/26/07 TEMP POLE SONOMA PH 1 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit pin number . 536961 Permit Fee . . . . 20.00 Issue Date . . . . 11/26/07 Valuation a. 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------------------------------------- J64or------------------------- BUILDING DEPT REPRESE&T-ATIVE: APPLICANT: (*//4" CITY OF COLLEGE STATION Planning 6 Development Services ADDRESS/LOCATION APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOV �aS 'FIEt� For Office Use Only DATE' l-101 TRCC REG APPLICATION # TEMP POLE # LOT LZ / ✓ LOCK �" SUBDIVISION SONG M /_\ SEC/PH l BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTACT PERSON FOR REVIEW COMMENTS: ERIC WIVAGG PHONE: 690-1222 ext. 120 FAX: 690-0348 EMAIL: ewivagg(aD_stylecraft-builders.com ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No ACCESSORY/STORAGE ADDITION DEMOLITION (Asbestos Survey) DUPLEX (Landscape Plans) LOCATION MOVING X NEW CONSTRUCTION REMODEURENOVATION* DESCRIPTION OF WORK: Conventional Framing PROPOSED USE: Single Family Residence '4 *'\ RE -ROOF SHELL ONLY SLAB ONLY SWIMMING POOL TENT/CANOPY WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPS Vj ENGINEERED ❑ HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ C1511 35 TOTAL AREA: 18152. HEATED AREA: 1443 (Cost of Labor and Materials) 4 atk� �X PUBLIC SEWER �1 ❑ SEPTIC/TREATMENT SYSTEM ,10 �X SEWER TAP: 4e SIZE FXJ WATER TAP: %11 SIZE b�� �� a �' 1t�� OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE ATTACHED • •'•• gr •' �'.r1• • • •Masonry E: lab on Grade Ro Composition DOUBLE%� ''r'LE D [;],CARPORT e— SIGNATURE OF APPLICANT: /l 7 0-1 For St lecraft *If proposed work involves new commercial c nst to or facade improvements/r n vations to an existing commercial property, building elevations are required. Official Use Only 7_1 ���-�..�� ✓J� ns Examiner Zoning Official -oil n/ . 3-A-01 ��iv� r 1• -/eat Comments: �J(� S� nor NO C� IbaM�v. Fire Marshall ((A_ > Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating Protection Against Subterranean Termites I2 % ✓ R13 R30 R19 .35 ❑ Chemical Termiticide Treatment (Soil Treatment) R6 Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other 19 *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. i PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS `� CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Service; COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 0%— 39 DATE: ,'`5_ol BUILDING ADDRESS: vS �edd save %ce I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex WOK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans NA/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing plan or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. K gAjV11K ►u PLAN REVIEW Vt*t/q"ONE and TWO FAMILY OCCUPANCY REQUIREMENTS . CITY OF COLLEGE STATION CITY OF COLLEGE STATION 1101 TEXAS AVENUE Planning& Development Service; COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX III. Stairway Requirements A. Stairway Details K 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N / 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ' ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vlll. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." LANS EXAMINER II,f.. �7 DATE REScheck Software Version 3.7.3 Permit # Permit Date Compliance Certificate Project Title: Plan #1443 Report Date: 11/07/07 Data filename: S:WCAD\Archived\Old REScheck\1443 205 Fieldstone.rck Energy Code: 2003 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 12% Heating Degree Days: 1788 Construction Site: Owner/Agent: Permit Date: 11/7/07 Maximum SHGC: 0.40 Your SHGC: 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Cathedral Ceiling (no attic): Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame, Double Pane with Low-E: SHGC: 0.40 Door 1: Solid: Door 2: Glass: SHGC: 0.40 Floor 1: Slab-On-Grade:Unheated: , Insulation Depth: 0.0' Air Conditioner 1: Electric Central Air: 13 SEER Furnace 2: Forced Hot Air: 80 AFUE Designer/Contractor: 1345 30.0 0.0 47 103 19.0 0.0 5 1626 13.0 0.0 114 178 0.670 119 38 0.500 19 18 0.580 10 201 0.0 209 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7.3 and to comply with therequirements listed in the REScheck Inspection Checklist. SIYLEGIZA� m a t'7o Builder/Designer Company ame Date Project Notes: Previously saved project information: Spec 205 Fieldstone College Station, Texas Stylecraft Builders Inc. 4090 State Hwy. 6 South College Station, Texas 77845 Plan #1443 Page 1 of 1