PREPARED 4/17/08, 8:03:44 INSPECTION TICKET PAGE 8
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/16/08
------------------------------------------------------------------------------------------------
ADDRESS . : 205 FIELDSTONE PL SUBDIV: SONOMA PH 1
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER . . PHONE
PARCEL . . 578700-0110-0220
APPL NUMBER: 07-00003287 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/03/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
12/03/07 AP November 30, 2007 11:49:17 AM glsouth.
MONDAY AM
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 1/04/08 RH BLDG, FRAMING TIME: 17:00
1/04/08 DP January 4, 2008 10:51:19 AM acarter.
O1/04/2008 03:24 PM RH PDA
Need proper APA nailing pattern.
B115 02 1/07/08 RH BLDG, FRAMING TIME: 17:00
1/07/08 AP January 7, 2008 10:44:55 AM kwolfe.
B130 01 1/09/08 RH BLDG, INSULATION TIME: 17:00
1/09/08 AP January 8, 2008 1:56:52 PM kwolfe.
B125 01 4/16/08 B I BLDG, FINAL TIME: 17:00
i April 16, 2008 1:15:46 PM npadilla.
-------------------------------------- COMMENTS AND NOTES ------ 0&-------------------
i _ .
From:STYLECRAFT BUILDERS INC 979 690 0348
01/17/2008 14:35 H393 P.008/010
. Oq - 301r7
Renewable 5 Year
Subterranean
Termite Retreatment
Agreement
(Does not cover any other species of Termites)
"Shielding & Protecting
Homes Against Pests"
This agreement provides for retreatment only of the infested areas covered under the original treatment areas (See Graph).
/
—6111)
Customer Name Date Billing Name if different
Street Address of treated structure
t 7j< Y�
City State Zip Code
Home Phone
Work Phone
Type of Treatment Partial Bait !Pre -Treat
Treatment for." Prevention Control of Subterranean
Termites
Billing Address if different
City
State Zip Code
Initial Termite Cost $e%.
Additional Renewals Paid.r
Other
—
Tag
Casb_Check# Total $--���—
Payment $�_
Balance $
Credit Card:
Type Exp. Date Card Number
5 Year Subterranean Termite Retreatment GuarantM, RP Lee Termite and Pest Control will retreat the structure for Subterranean
Termites at no cost to the customer, if an infestation of Subterranean Termites is found, as long as the original treatment is paid in full
and the customer is current on their yearly renewals. This Agreement will expire in one (1) year unless the customer elects to pay
the yearly warranty fee. The guarantee can be renewed for up to five (5) years by paying the yearly warranty fee. RP Lee Termite
and Pest Control may approve additional warranty years after -the five (5) yearn with an additional increase in the yearly warranty fee.
The guarantee does not cover any damages to the structure or contents of the customer The customer agrees to control all condusive
conditions that may cause reinfestation. If the structure is modified, added on to, altered, or if the soil treatment around the structure
is removed the customer must contact RP Lee Termite and Pest Control and pay for additional treatment in order to keep the guarantee
in effect If the customer does not pay for additional treatment the retreatment guarantee can be cancelled_
,renewal Fee: Customer may elect to renew the retreatment guarantee for additional years. The renewal fee is $ plus tax_
The renewal fee is due on or before the annual anniversary date or paid $ plus tax every third (3) month with imypction.
arc mug a uaran : e customer agrees to correct a 1 con usive nditions, at owner's expense, as they exist or as they
occur in the future in order for the guarantee not to be cancelled. Customer will make the structure available for inspections and
treatments as requested by RP Lee Termite and Pest Control.
Reinspection: RP Lee Termite and Pest Control will reinspect the structure at customers request or any other times RP Lee Termite
and Pest Control deems necessary. RP Lee Termite and Pest Control recommends that the customer call and set up an annual inspec-
tion at the time of customers yearly renewal.
'Transfer.This agreement may be transferred to a new owner with the payment of a transfer fee of $ / , copy of the Wood
Destroying Insect Report from the sell, and approval of RP Lee Termite and Pest Control.
This -Subterranean Termite Retreatment Guarantee dots not prevent and is not intended to control other forms of Termites
013mood Formosan etc 1. Wood Boring Beetles CarpenterAnts Carpenter Bees. Wood Rot Fungus- Decay or any other
wood destroying inserts or organisms.
Arbitration: In the event of any dispute arising out of this agreement or any other services performed or not performed the parties
above agree to participate in mediation through and in accordance with the commercial mediation rules of the American Arbitration
Association. The Arbitrator shall consider the legal defenses raised in the arbitration, and the decision of the arbitrator shall be final,
binding, non -appealable and may be entered and enforced in any court having jurisdiction in accordance with the Federal Arbitration
Act
Limitation of Liability: Landscaping and grass next to the slab may be damaged during treatment, carpet may need to be pulled
up in certain areas around the home, drill holes may need to be made in floor coverings such as tile or linoleum or in cabinets next
to pipe areas, and holes may need to be cut in walls. Customer agrees not to hold RP Lee Termite and Pest Control liable for these
damages, or treatment techniques, or other damages that may occur during treatment
Agreement: This Agreement shall be the entire agreement between customer and RP LeeTermite and Pest Control. If any part of
this agreement is found to be invalid it shall not affect the validity of arty other part of the Agreement.
We are licensed by the Structural Pest Control Board - 333-Gundalun&. Swig 1-530
Austin, 3[% 78701 512-305-8250
RP Lee Termite Pest Control
Cert. Apl.# customer ignature Date
From:STYLECRAFT BUILDERS INC 979 690 0348 01/17/2008 14:35 #393 P.009/010
SUBTERRANEAN TERMITE PRE -CONSTRUCTION TREATMENT DISCLOSURE FOR EACH ESTIMATI
Licensed and regulated under the Texas Structural Pest Control
RP LEE TERMITE & PEST CONTROL
PO Box 9423 College Station, TX 77842 • 072) 690-8622 • TPCL #11486
- CUSTOMER INFO TIO�
Name: YZ ea. Phone #1: Phone #2:
Address: City: State: Zip Code:
Location to be Treated: �.7 r F C� Tj a'� el. S . ;if 77' o J -
For all treatments there will be a diagram showing exactly what will be treated priorto the beginning of treatment Review the Pesticide LI l provided to you at this time for minimum treatmentstandal
Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the law. Review the consumer information sheet for further information. If
have any questions, contact the pest control comoany or the Texas Structural Pest Control Board, P.O. Box 1927. Austin, TX 78767-1927. Telephone number (512) 305-8250.
Before conducting a termite premnstruction treatment, the company snfill present a complete diagram of the structure including construction details. When construction prevents performance of a
treatment, in accordance with a bid for full treatment, any change to a partial treatment by the company providing the treatment Will be permitted if the owner of the structure or the person in dtarg(
the construction and the certified applicator for the pest control company sign a statement attesting to the construction conditions. The agreement must be attached to the contract with an amen(
diagram showing the exact areas to be treated. Copies must be sent to the owner of the property within seven days of the application.
M'p�
Diagram
HIMU
off
Structure(s)
in
and
ME=
Proposed
Area(s)
To Be Treated
11111121111111111111
■■■.MEMEM
■!!h!`.-:■■�.11■r��ii.la■■■■■■■i■
'■i■::ii'1.'.�■
am
W
■■■■■■■■■■■■U■■■■■■!■■■■.■■■Il■.■■■■■■.■!■■■W■■■■■
■■
■!■■
OOm
■■■
AN=
■@!■■!.i■■■■�■■1..■!
■■■�
�■■�■■O■■■C■■!1■0■■■f
Uri■■■■■■■!■■
manvo
m■■■
viEam
...■.■
■■■■■m■.ME
■■�.;■'■s■■
m■
m■■■■O■1
■■!■1■.■■■
■■■■■■■li■■!■!■.■1■■■
■>t■!■■■ia
CC
lr..■!:3■,■��..■''�CC!"!'.v:CC:�'.�'■I�CC:�CC:'t:■':'■:■�
u■
mom
rung
"�>t�ii
'■:iC■"■■■■
.n
��1.!■■sm!■■lmE
•�s
i
■■lliCivamm■■■■■■■■■!
MOM
LWA2WiL.■■C:/f:■■l2
■.p.■�.1
!!
11111M■
gi■■■ii■■i■■■■'
Qi!:Ci■'CC'�iiaso
■iC■m/.
_W
m�■i�i'■■C■ii
■M■■■■i1■'■■■■■■1�■.■■I�■■■u1�0!■�/■■..■�
■■■n■■■n
...■.■a■■■■m■■■.■■■�■■■■r■,!h...��..�.�
■■mtll■■■!!Om■Q■■
MOM
!
!
■■■1■■■■■■■■.■■■■.■r>■■1■!
■i■■■.■I•�■■■■■IN■■■!■ti■MO.!
■■mm■■■■■■■■■■■!m■a�m■min
mtillmtl(wm■■
.■■.
■O■■■.;tll1
■lmmmm
■ a■■■■■■■■
■■!/■■■O■m■■■■1■m
■■■■■■f
m■�p
■■MO"=O
-no
■■■m■■IA■■m■■■■■■!■■p■■m/.■
.lnl•�miil■■■:"wm■■.■!■■■■
E■!■n■H■■■■n■■■■O.■■■m■■.
la; ■■MMIN
■■!m!m
■■amos■m.lf■tl■>�■.orE■;a
Samoa
■■ma■>t.®
.m
a
mint...■■ME
MENEM
.m■■!■■.....■�■�1/�r
■■■....m■v■■■m!■■■■.,!■■.■■.HmS■■
m
om»•��
+��11im.
■■■■
m■m■mmm■■■m■■!m■■■!■■■■■■m
IMEN■■■'C:y'■'u"■oiui■miinw■■■m■■
.'■miffEN
ffuu'■)t■
notes: &09CAfe
�7,
6t/yae) 2 ( ow,— T r
s1,05
;g De
4:1.-Towei-TI
Type of treatment proposed: (check all that apply): ❑ Full Partial *OVVood ❑ Bait ❑ Commercial CICSingle Family
Total square feet to be treated: _ Total linear feet to be treated: Approximate measurements of structure(s) to be treated: el'01 F
A label of fg E1dA P'410e tenniticide(s) is attached. The percentage of the termiticide(s) to be applied at this location is %.
Estimated amount of termiticide to be applied: r gallon(s).
THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREALTMEN r-BUILDERS GUIDE IS ATTACHED ON BACK (SPCE113 4) THE BOARD APPROVED SUBTERRANEAN TERMITE
PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUCTION TREATMENT
SERVICE. Complete details of warranty (if any) including time period of warrant)4 renewal options and cost, and obligations of the contracting parties is attached. If the warranty does not
include the entire structure treated, the areas included in the warranty are (specify):
4- A consum 'nfornation sheet is also attached.
le -Y.1011eel
Signature of CA or chniaan Printed Name Date Signature ofMtomer Verifying Receipt of This Document Date
11Htsslrn340-2.• otmaor white Copy - ServicePmvider YenowCopy -Customer
Fur od9W ad Fiitee by ScrvfootgM Coanv—ems t-MWs24M.Oedb. TX caw;
Service Treatment Invoice
Route: 6 Map Code:.
Start Time: m/pm Finish Time: ---am pm
Type of Service: f` itial Regular Follow Up One Time Charity
Service Address
Name:
Address:
City: (I � TX
Phone:
Billing:
iEE
"Shlelding & Protecting
Homes Against Postal'
TPCL #11486
Date: r �'" ?U�/ Appoiut.Timc: Ir am/pm
Frequency: � BM Q S Y
Structure: labs Crawl P/B Combo
Pets: Dog(s) Cat(s) Bird(s) Fish A./4.
Cost of Service $ cue.?.
TAX. $
Total Due $ 1,7-0
Payment $
Balance It - ,7FU -
PEST PROBLEMS: d- DIRECTIONS / INSTRUCTIONS:
EQUIP. METH. LOCATIONS) PRODUCT
WOOD DESTROYING INSECTS
GENERAL PESTS
I FLEAS
i
MFCE RODENTS AT MONITOR
OTHER
QTY
TARGET PEST(S)
Payment by:
Cash ❑
Check ❑ #
Credit Card ❑
PAYMENT DUE
UPON RECEIPT
Termidor SC-Fipronll .06%
Termidor BOW Fipronll
Subterranean Termites, Ants Size of Tanis . Posted
.06%
Hole-careDlsodlum OMaborete'Ibtrahydate 50%
Subterranean Termites. Size of Tank Posted
Su bterranean/Fottnosan/Drywood Tiermtles, Carpenter Ants, Beetles, Posted ._• 4:
Invader HPH-Baygon 1%
Carpenter Ants, Spiders, Crickets, Millipedes, Beetles, Termites.
Demon WP-Cyaho•Phenoxyphegyl
Cockroaches, Millipedes, Sowbugs, Flies, Ticks, Mosquitos, Plllbugs,
Dlmethycyleyclopropan¢carbozytate 1%
Tempo Ultra WP-Cyfiuthrin .02$% (Rest)
Silverfish, Bees, Ants, Carpenter Ants, Scorpions, Spiders.
(gen. surface spray, spot, mist, crack & crevice)
Ants (Except Pharaoh), Cockroaches, Crickets, Earwigs, Millipedes, Flies, Fruit Flies, Beetles,
Plllbugs, Silverfisb, Spiders, Gnats, Hornets, Wasps, Yellow Jackets.
Telster EZ Blfenthrin .2%
Maxforce-Hydramethylon 1%-2ti1S%
Ants, Centipedes, Cockroaches, Crickets, Grasshoppers, Scorplonsjlcks, Silverfish, Spiders.
Cykick CS Cyttuthrin
PharachAots, Crickets, Carpenter Ants, Lg. Roaches, Variety of Ants.
.05%
Phantom
Spiders, Scorpions,Ants, CarpenterAats, Carpenter Bees, Roaches, Crickets, Silverfish.
.5%
Pbaroh Ants, Varlety of Ants, Roaches.
Tengard-Permethrin .5% Fleas, Ticks, Ants, Centipedes, Carpenter Ants, Bees, Wasps, Carpenter Bees, Cockroaches,
Crickets, Flies, Earwigs, Millipedes, Beetles, Plllbugs.
Suspend MethySC-Deletnox rin %4.(R5 ST) Fleas, Bees, Beetles, Roaches, Crickets, Lice, Flies, Scorpions, Ticks, Wasps.
NygueR Pyrekyletn05 10% (R 9T) IGR-Growth Regulator-Flens, Roaches, Crickets, Flying Insects, Stored Product Pests.
Excite R Pyrethrin .OS% Fleas.
Fastrac-Bromethalln .01% Mice, Rodents, Rats.
Bait Station-Large/Small Glue Boards Mice, Rodents, Rats, Bug Monitors.
Speckoz-Pyrocide .50% Houseflies, Mosquitos, Moths, Flens, Wasps, Hornets, Ticks, Cockroaches.
Blfen I/T Blfenthrin .06% Splders,Auts, Roaches, Silverfish, Earwigs, Fleas, Scorpions
Mitipment: A -Compressed Sprayer P-Power Sprayer B-Bait Dispenser BS-Bait Station BVBait Tiap D-Aerosol Can G-Glue Board H-Hand Duster S-Spreader F-Fogger FM-Foamer AC-Actisol unit Other
Locations: 1-Kitchen 2-Bath(s) 3-Bedrooms 4-Dining Room 5-Utility 6-Storage 7-Common Areas 8�Galage 9-Perimeterof Structure 10-Attic I1-Yard 12-Under Home 13-Warehouse 14.Office 15-Exposed Wood 2' up from Slab Other
Method of Treatments: CC -Crack & Crevice SS -Sub -Slab Injection VT -Void Treatment BP -Bait Placement BS-Broadcast Spray PB-Perimeter Barrier BV-Brick Venire WT-Wood Treatment
PRECAUTIONS: Do not touch treated areas till dry. Do not tampet with bait stations. Ventilate rooms after treatment. Keep pets away until pesticides have dried.
Licenced by the Structural Pest Control Board - 333 Guadalupe, Suite I-530 • Austin, TX 78701.512-305-8250
SERVICE TECHNICIAN:.
�� � = �- CUSTOMER SIGNATURE: _ l�i� a�%�''''� t%�.. ��ff DATE: •/�"�%-�%
O
R
C/)
r
M
C-D
n
00
C
0
M
Cn
z
CD
v
cD
co
CZ)
CZ)
CA)
A
Co
W
O
v
N
C7
CZ)
co
.A
W
O7
CD
CIO
0
CD
CZ>
CD
From:STYLECRAFT BUILDERS INC 979 690 0348 01/09/2008 09:44 #193 iPOf/OA t'S;�7
U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE OMB No. 1660-0008
Federal Emergency Management Agency I Expires February 28, 2009
National Flood Insurance Program Important: Read the instructions on pages 14
SECTION A - PROPERTY INFORMATION
le �.
o
N, ' �'-
e'`C�k
1'
Al. Building Owner's Name
S lecraft Builders
A2. Building Street Address (Including Apt., Unit, Suite, and/or Bldg. No:) or P.O. Route and Box No.
205•Fieldstone Place
r vp yi9�,YY
e;
�21 �I �i3 ' „
Ei "i" f n�fWeii.
v oldie ZIP Code
College Station Texas 77M
A3.. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
Sonoma, Phase 1, Block 1, Lot 22
A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential
A5. Latftude/Longftuds: Lat. N 30deg 33.390 Long. W 96deg 17.420 Horizontal Datum: ❑ NAD 1927 NAD 1983
A6. Attach at least 2 photographs of the building If the Certificate is being used to obtain flood insurance.
A7. Building Diagram Number 1
l s A8. For a building with a crawpace r enclosure(s), provide: : A9. For a building with an attached garage, provide:
a) Square footage of crawl spat or enclosure(s) sq ft a) Square footage of attached garage sq ft
b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage
enclosure(s) walls within 1.0 foot above adjacent grade walls within 1.0 foot above adjacent grade
c) Total net area of flood openings in A8.b sq In c) Total net area of flood openings in A9.b sq In
SECTION B - FLOOD INSURANCE RATE -MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number 62. County Name B3. State
Cityof Bryan 480082 Brazos Texas
B4. Map/Panel Number
B5. Suffix
B6. FIRM Index
B7. FIRM Panel
B8. Flood
B9. Base Flood Elevation(s) (Zone
Date
Effective/Revised Date
Zones)
AO, use base flood depth)
48041CO205
D
7-2-92
2-9-2000
AE
321
tito. inaicate me source of the Base Flood Elevation (BFE) data.or base flood depth entered in Item B9.
❑ FIS Profile FIRM []Community Determined ❑ Other (Describe)
B11. Indicate elevation datum used for BFE In Item B9: ❑ NGVD 1929 ❑ NAVD 1988 nOther (Describe) local
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes No
Designation Date ❑ CBRS ❑ OPA
SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
Cl. Building elevations are based on: ❑ Construction Drawings* O' Building Under Construction' ❑ Finished Construction
'A new Elevation Certificate will be.required when construction of the building is complete.
C2. Elevations —Zones Al-A3.0, AE, AH, A (with BFE), VE, VI-V30, V (with BFE), AR, AR/A, AR/AE; AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-g
below according to the building diagram specified in Item A7.
Benchmark Utilized Subdivision BM Vertical Datum
Conversion/Comments .Property is not in the FEMA 1 % or 100 year floodpl in, but the City of College Station requires a MFF 322 ft for stormwater
Check the measurement used.
a) Top of bottom floor (including basement, crawl space, or enclosure floor) 322.00_0 feet ❑ meters (Puerto Rico only)
b) Top of the next higher floor
c) Bottom of the lowest horizontal structural member (V Zones only)
d) Attached garage (top of slab)
e) Lowest elevation of machinery.or equipment servicing the building
(Describe type of equipment in Comments)
f) Lowest adjacent (finished) grade (LAG)
g) Highest adjacent (finished) grade (HAG)
❑ feet
feet
_❑ feet
_ ❑ feet
321.07 feet
12A.38_0: feet
❑ meters (Puerto Rico only)
❑ meters (Puerto Rico only)
❑ meters (Puerto Rico only)
❑ meters (Puerto Rico only)
❑ meters (Puerto Rico only)
❑ meters (Puerto Rico only)
SECTION D-SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify ele%
information. l certify that the Information an this Cerftate represents my best efforts to interpret the data available:
1 understand that any false statement may be punishable!by fine or impnisonmeht under 18 U. S: Code, Section 1001.
❑ Check here if comments are provided on back of form.
Title
;F ,t
License Number'
5743
o�
State ZIP Code
Texas T7803
Telephone
,3*�
:979-779-7670
FEMA Form.81-31, February 2006 See reverse side for continuation. Replaces all previous editions
From:STYLECRAFT BUILDERS INC
979 690 0348 01/09/2008 09:44 #193 P.002/003
Building Photographs
See Instructions for Item A6.
Building Street Address (including Apt, Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number
ZIP
Station
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to
the instructions for Item A6. Identify, all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right
Side View" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page,
following.
Finish Floor Elevation
High Elevation
From:STYLECRAFT BUILDERS INC 979 690 0348 01/09/2008 09:45 #193 P.003/003
Building Photographs
Continuation Page
Building Street Address (including Apt, Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number
If submitting more photographs than will fit on the preceding page, affm the additional photographs below. Identify all
photographs with: date taken; "Front View' and "Rear View"; and, if required, "Right Side View" and "Left Side View."
Low Elevation
May.30, 2008 8:43AM Stylecraft Builders, Inc. No.1225 P. 2
Mats bu ud u'I :J4a Pau i w 1 1 1 i ams Lana Survey 9797797G72 Iva 3
;s? U:. CrEPARTMENT OF HOMELAND secuRr Y . CLG V A I 1 VIV %wr.M I I ri%o '► I C Exoir bruit v 28
Federal Emergency Management Agency
Exnir®s Febtvary 28.2009
National Flood Inswance Program Important: Read the instructions on pages 1-8.
SECTION A- PROPERTY INFORMATION ForIirstinceiiti>ise= `
9 Name
Al. Building Owner'
Aaron Boswell and Theresa Boswell
A2. Sunding StreetAddreea (including Apt., unit, sutlo, and/or Bldg. No.) or P.O. Route and Sox No. CarTit aTl �FififC fitli ter!' � •" _
2W Fleldatane Place
city Stan® ZIP Code -
coir a Statron Texas 77845
A3. Property Dsscdpllon (Lot and Block Numbers, Tax Parcel Number, Legal Descrlplion, etc,)
Sonoma, Phase 1, Block 1, Lot 22
A4. Bddfng Use (e g.. Residential, Non-Resldentlal, Addttlon, AvAmory; etc.) Residential
A5. LatlturWLongkWe: Lat. N 30deg 33.390 Long. W 96deg 17.420 Horizontal Datum: ❑ NAD 1927 NAD 1983
A$. Attach at lust 2 photographa of the building if the Certificate Is. being used to obtain flood Insurance.
A7, Building Diagram Number 1_
A& For a building with a crawl space or enclosure(s), provide: Ag. For a building with an attached garage, provide:
a) Square footage of crawl space or enclosures) sq ft a) Square footage of attached garage _ .. _ _ _ sq ft
b) No. of permanent flood openings In the crawl space or b) No. of permanent flood openings In the attached garage
enclosure(s) walls wlth In 1.0 foot above adjacent grade walls within 1.0 foot above adjawd grade
c) Total not area of flood openings in AS.b sq In c) Total net area of Stood openings In A9.b sq in
SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
81. NFIP Community Name A Community Number B2. County Name TW8tate
Oy of College Station 480083 Brazos Texas
154, Map/PaW Number
95. Suffix
B6. FIRM Index
B7, FIRM Panel
58. Flood
59. am@ Flood FJevation(s) (zone
Date
Effective/Revised Date
Zones)
AO, use base flood depth)
48041CO205
D
7•$•92
2-9-2000
AH
. 321
910. Indlcals the source of the Base Flood Elevation (BFM data or base flood depth entered In Rem B9.
❑ FIS Profile FIRM ❑ Community Determined ❑ Other (Describe)
811. Indicate elevation daturn used for BFE in hem Be: ❑ NGVD IM ❑ NAVD 1988 Mother (Descrlba) local
812- Is the building located in a Coastal Barrier Resources System (CSAa) area ar Otherwise Protected Area (OPA)? ❑ Yes 0 No
Designation Date ❑ CBRS ❑ OPA
SECTION C - BUILDING ELEVATION INFORMATION (SUAVV RMUIRL:D)
Cl. Building elevations are based on, ❑ Construction Drawings' ❑ Building Under Conshvetion' Finished Construction
A new Oevabon Certificate will be required when construction of the building is complete.
C2. 'Etavadons —Zones Ai-A30, AE, AK A (with BFq, vE, VI-V30, V left SM, AR, ARIA, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items 02.a•g
below according to the building diagram specified In Item A7.
Benchmark UGlizad Subdivision BM Vertical Datum
Converskin/Oamments Property is not 1n the FIEMA 1 % or 100 year floodplain, but the City of Co@egs Station requires a MIFF 322 R for stonnwater _
Check the measurement used.
a) Top of bottom floor (including basement, crawl space, or enclosure floor)
b) Top of the next higher floor
c) Bottom of the (owest hoti2onml structural member (V Zones only]
d) Attached garage (top of slab)
a) Lowest elevation of machinery or equipment servicing the buikflng
(Describe type of equipment In Comments)
f) Lowest adjacent (finished) grade (LAG)
g) Highest adjacent (finished) grade (HAG)
=68 , feet
feet
lost
_❑ feet
_❑ foot
meters (Puerto Rico only)
meters (Puerto Rico only)
meters (Puerto Rico only)
❑ meters (Puerto Rico on)y)
❑ meters (Puerto Rico only)
feet ❑ meters (Puerto Film only)
M25 feet ❑ meters (Puerto Rico only)
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This rerttficattan Is to be signed and Sealed Dy a lama Surveyor, engineer, or arcnitect aumormw oy law to cerary ale
information, / cerW that the InlonnoWn an Mis Cdifflh a reprrea" my best efforts to intemml the lotto avaHW&
I understand Mat any false statement maybe punishable by fine or frtip6sonmerrt tinder 18 U.S. Code Sedan 1001
0 Check here if comments are provided on back of fort.
FEMA Form al-31, February 2008 See reverse side for continuation. Replaces all previous editions
Ma May.30. f-.'3,�$:44aMPaul 1irlfamS 1Bann' Iurve 9797797672 No. 1225 P, 4
J y p•
Building Photographs
Corttinuatlon Page
For Insurance Company Us4
Build9ng Street Addrm (Indudino Apt., Una, Suite, arWor Eodg. No.) or P.O. Fkoute and Box No. Polley Number
205 Fieldstone Place
Gay State ZIP code company tJAEc NurMw
-1-
If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all
photographs with: date taken; "Front View" and 'Rear View"; and, if required, "Right Side Vleve and `Leff Side View."
Low Elevation
May,30. 2008:44aM S t y I e c r a f t Builders, Inc,
Mai :%U un ur:14a Paul W1111ams Lana survey 9797797672
No.1225 F. 4-
p. a
Building Photographs
AAA inntnirtiAnS fnr item AS.
For Insurance Company Usa:
Building street Address (including Apt, Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Poky Numtw
2D5 Fleldstone place
City State ZJP Code cotr�aany �u nwrwer
Calve Station Texas n
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to
the instructions for Item A6. Identify all photographs with: date taken; "Front View" and "Rear View"; and, If requirad, "Right
Side View" and °Left Side View." if submitting more photographs than will fit on this page, use the Contlnuatlon Page,
following.
Finish Floor Elevation
High Elevation
(5/5/2008) Gina Southerland Re: Calling for CO for 205 Fieldstone PI .. � Page 11
From: Joe Garcia
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Kim W...
Date: 4/18/2008 4:19 PM
Subject: Re: Calling for CO for 205 Fieldstone PI
NO FOR CO. SEWER BOX IS BURIED. JMG
>>> Amber Carter 04/17/08 1:42 PM >>>
by 07-3287
Any issues?
I/2- DIA. SMOOTH DOWEL 2'-0-
LONG W/ PVC CAP - PLACE IN
$lA8 OR DRILL 9' INTO EXISTING
GRADE BEAM. TAPE CAP TO LEAVE
TOOL EDGE E.J.T. 1' ® END OF ROD
4' THICK PAVING 3000 PSI
REINF. W/ 83's ® 18' O.C.E.W.
MID DEPTH USE CHAIR SUPPORTS
DISCONTINUE REINF. O E.J.
1x REDWOOD DIVIDER
D SECTION "D"
N.T1
CONTINUE REINFORCEMENT
THROUGH KEYWAY
ONE CHAIR PER 4' THICK PAVING 3000 PSI
4 SO. FT. MIN. REINF. W/ 13's ® 18' O.C.E.W.
MID DEPTH USE CHAIR SUPPORTS
C SECTION "C"
N.rs.
3/8- DIA. DOWEL W/ SLEEVE.
DRILL INTO EXISTING SIDEWALK
Ix REDWOOD =
B SECTION T"
N.TS
�DRILLINTO
-W/ SLEEVE.
G CURB
8' X 8'BEAM
W/ 4 �5 REBAR
A SECTION "A"
N.T3.
d <
d �—
d
°
INSTALL EXPANSION JOINT °
0 MID -DRIVE IF OVER 45'
PR
4'REINIFORCEOPSI
CONC.
6 S
18W//%3O.C.E.W.
OF I SIDEWFY ALKI� CITY SIDE WALK
IN FIELD
MAI L
LAYDOWN CURB DETAILS
Q
c
d
CONTRACTION JOINT WHEN
DRIVE G 16 WIDE
4" THICK 300q PSI CONC
REINFORCE W/ #3 BARS
® 18" O.C.E.
CONTRACTION JOINT
E PTALL JOINT3/ METAL KEYWAY
$'ADIA.
SLICK DWLS. 0 18 O.C.
W/ SLEEVES ONE SIDE
WATER VALVE COVERS
205 FIELD STONE PL
SONOMA
PHASE- 011 BLOCK- 011 LOT- 22
.0
T7
0
C3
0.
L O
0Io,E
N v m C V
C 0
3ru_v
v CNL,
�= ON
N
cina u
o �n o,o• .T
UO v
On
v vVL,
JOB#:
07173
J
Z
O
U F-
LLJ V)
w
Li-
Ln
CD
CV
PRE -CON
CREATED:
11/7
PRE -CON:
REVISED:
ISSUED:
PRINTED:
1 1 /7
Q
00
v-
w
� M
d'
r--
H
SCALE: -
1 •-2a
C-1
BUILDING PERMIT
CITY OF COLLEGE STATION
1101.,TEXA18 AVENUE, COLLEGE STATION, TX 7784a
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00003287
382096
205 FIELDSTONE PL
578700-0110-0220
Date 11/26/07
RESIDENTIAL, 1 UNIT DETACHED NEW
SONOMA PH 1
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
95238
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION TX 77845
(979) 690-1222
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE MASONRY
IMPACT/PRORATA FEES PAID DUE
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1443.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TRAFFIC IMPACT ANAL (TAZ) 427.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit pin number .
536953
Permit Fee . . . .
444.00 Plan Check Fee .00
Issue Date . . . .
11/26/07 Valuation . . 95238
Expiration Date . .
5/24/08
Qty Unit Charge
Per Extension
BASE FEE 260.00
46.00 4.0000
THOU BLDG, VAL 50001-100000 184.00
----------------------------------------------------------------------------
Special Notes and Comments
-Minimum Finished Floor
of 322' for F ood Management,
Elevation Certificate
- -
Ap
-----requires
----------------------------
BUILDING DEPT RE$R7SENTATIVF,:,
-- -----------------------
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101,TEXAS AVENUE, COLLEGE STATION, TX 7784C
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00003287
Application pin number . . . 382096
Page 2
Date 11/26/07
Special Notes and Comments
-Narrow Wall Bracing Fully Sheathed with 16" minimum APA
Garage Framing
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 301-) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/O ACCESS MAY HAVE TO
--------------------------------------------- ----ij-;PaA; ----------
BUILDING DEPT REP SE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101,TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
--------------------------------------------=-------------------------------
Page 3
Application Number . . . . . 07-00003287 Date 11/26/07
Application pin number . . . 382096
----------------------------------------------------------------------------
Special Notes and Comments
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER'PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
--
------------------------------------------------f'�.i•-- - ------------
BUILDING DEPT REPRESTIVE:_
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101.TEXAS AVENUE, COLLEGE STATION, TX 77840-
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00003287
Application pin number . . . 382096
Page 4
Date 11/26/07
Special Notes and Comments
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 2001 A .40 OR LOWER FACTOR AND ABOVE 200
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
ELEVATION CERTIFICATE REQUIRED - PROVIDE ELEVATION
CERTIFICATE PRIOR TO SLAB INSPECTION AND A SECOND
CERTIFICATE PRIOR TO FINAL INSPECTION/C.O.
Other Fees
SEWER TAR 4"
BUILDING DEPT REPRES 4LTIVE:
APPLICANT:
350.00
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840-
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 5
Application Number . . . . .
07-00003287
Date 11/26/07
Application pin number . . .
382096
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
---------------------------
Paid Credited
--------------------
Due
----------
Permit Fee Total 444.00
444.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total 1194.00
1194.00
.00
.00
44A;�
`---------------------------------------------------------
BUILDING DEPT REPRES TA I .
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00003288
525504
205 FIELDSTONE PL
578700-0110-0220
Date 11/26/07
TEMP POLE
SONOMA PH 1
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION
TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit pin number
. 536961
Permit Fee . . .
. 20.00
Issue Date . . .
. 11/26/07
Valuation a.
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
---------------------------------------- J64or-------------------------
BUILDING DEPT REPRESE&T-ATIVE:
APPLICANT:
(*//4"
CITY OF COLLEGE STATION
Planning 6 Development Services
ADDRESS/LOCATION
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
�aS 'FIEt�
For Office Use Only
DATE' l-101 TRCC REG
APPLICATION #
TEMP POLE #
LOT LZ / ✓ LOCK �" SUBDIVISION SONG M /_\ SEC/PH l
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTACT PERSON FOR REVIEW COMMENTS: ERIC WIVAGG PHONE: 690-1222 ext. 120
FAX: 690-0348 EMAIL: ewivagg(aD_stylecraft-builders.com
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
ACCESSORY/STORAGE
ADDITION
DEMOLITION (Asbestos Survey)
DUPLEX (Landscape Plans)
LOCATION
MOVING
X NEW CONSTRUCTION
REMODEURENOVATION*
DESCRIPTION OF WORK: Conventional Framing
PROPOSED USE: Single Family Residence
'4 *'\
RE -ROOF
SHELL ONLY
SLAB ONLY
SWIMMING POOL
TENT/CANOPY
WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPS Vj ENGINEERED ❑
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $ C1511 35 TOTAL AREA: 18152. HEATED AREA: 1443
(Cost of Labor and Materials)
4 atk� �X PUBLIC SEWER
�1
❑ SEPTIC/TREATMENT SYSTEM
,10 �X SEWER TAP: 4e
SIZE
FXJ WATER TAP: %11
SIZE
b��
�� a
�'
1t��
OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE
ATTACHED
• •'••
gr
•' �'.r1• • • •Masonry
E: lab on Grade
Ro Composition
DOUBLE%� ''r'LE
D [;],CARPORT
e—
SIGNATURE OF APPLICANT: /l 7 0-1 For St lecraft
*If proposed work involves new commercial c nst to or facade improvements/r n vations to an existing
commercial property, building elevations are required.
Official Use Only
7_1 ���-�..��
✓J�
ns Examiner
Zoning Official
-oil n/ . 3-A-01 ��iv� r 1• -/eat
Comments:
�J(� S� nor NO
C� IbaM�v.
Fire Marshall
((A_ >
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
I2 % ✓
R13
R30
R19
.35
❑ Chemical Termiticide Treatment (Soil Treatment)
R6
Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
19
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
i
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
`� CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Service; COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 0%— 39
DATE: ,'`5_ol
BUILDING ADDRESS:
vS �edd save %ce
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
WOK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing plan or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
K
gAjV11K
►u
PLAN REVIEW
Vt*t/q"ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
. CITY OF COLLEGE STATION
CITY OF COLLEGE STATION 1101 TEXAS AVENUE
Planning& Development Service; COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N /
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW '
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vlll. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
LANS EXAMINER
II,f.. �7
DATE
REScheck Software Version 3.7.3
Permit #
Permit Date
Compliance Certificate
Project Title: Plan #1443
Report Date: 11/07/07
Data filename: S:WCAD\Archived\Old REScheck\1443 205 Fieldstone.rck
Energy Code:
2003 IECC
Location:
College Station, Texas
Construction Type:
Single Family
Glazing Area Percentage:
12%
Heating Degree Days:
1788
Construction Site:
Owner/Agent:
Permit Date: 11/7/07
Maximum SHGC: 0.40 Your SHGC: 0.40
Ceiling 1: Flat Ceiling or Scissor Truss:
Ceiling 2: Cathedral Ceiling (no attic):
Wall 1: Wood Frame, 16" o.c.:
Window 1: Metal Frame, Double Pane with Low-E:
SHGC: 0.40
Door 1: Solid:
Door 2: Glass:
SHGC: 0.40
Floor 1: Slab-On-Grade:Unheated: , Insulation Depth: 0.0'
Air Conditioner 1: Electric Central Air: 13 SEER
Furnace 2: Forced Hot Air: 80 AFUE
Designer/Contractor:
1345 30.0
0.0
47
103 19.0
0.0
5
1626 13.0
0.0
114
178
0.670
119
38
0.500
19
18
0.580
10
201
0.0
209
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Version 3.7.3 and to comply with therequirements listed in the REScheck Inspection Checklist.