(2/20/2008) Kim Wolfe Re Calling for C.9 @LL2420 Stone Castle Cir Page 1 ;
x _
From: Paul Schoenfeld
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G...
Date: 2/20/2008 4:06 PM
Subject: Re: Calling for C.O. @ 2420 Stone Castle Cir
ALL OK.
PAUL
>>> Gina Southerland 2/19/2008 12:13 PM >>>
BP# 07-3247
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.Qov
PREPARED 2/19/08, 12:07:14 INSPECTION TICKET PAGE 11
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/19/08
------------------------------------------------------------------------------------------------
ADDRESS . : 2420 STONE CASTLE CIR SUBDIV: CASTLEGATE PH 1 SEC 7
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER . . PHONE
PARCEL . . 184200-1720-0200
APPL NUMBER: 07-00003247 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B115 01 12/17/07 OC BLDG, FRAMING TIME: 17:00
12/17/07 AP December 13, 2007 11:56:30 AM kwolfe.
1 B130 02 12/20/07 RH BLDG, INSULATION TIME: 17:00
12/21/07 AP December 20, 2007 4:54:23 PM kwolfe.
late as possible ........ per Robin
December 21, 2007 11:47:39 AM kwolfe.
B130 01 12/20/07 RH BLDG, INSULATION TIME: 17:00
12/20/07 DP December 20, 2007 7:59:50 AM kwolfe.
thursday afternoon
12/20/2007 02:41 PM RH PDA
Did not fix previous notes on a/c ducts. Need proper fire
blocking for fireplace to attic. Tape seal doors and
windows properly. Repair.and seal moisture barrier. Cut
insulation to fit , do not overstuff. Insulation mising in
areas. Seal seams, cracks, around windows ect...
B125 01 / 9/08 A
BLDG, FINAL TIME: 17:00
February 19, 2008 10:17:42 AM acarter.
-------------------------------------- COMMENTS AND NOTES ------------------- /01/-------------
D
From:STYLECRAFT BUILDERS INC 979 690 0348
12/03/2007 18:00 #620 P.005/007
Renewable 5 Year
Subterranean
Termite Retreatment
Agreement
(Does not cover any other species of Termites)
"Shielding & Protecting
Homes Against Pests"
This agreement provides for retreatment only of the infested. areas covered under the.ori&.al treatment areas (See Graph).. .
Customer Name Date Billing Name if different
i
Street Address of treated structure Billing Address if different
City State Zip Code
Home Phone
Work Phone
Type of Treatment Partial Bait VPre-Treat
Treatment for: Prevention Control of Subterranean
Termites
City
State Zip Code
� ram
Initial Termite Cost $ ✓2G .
Additional Renewals Paid
Other
Taxt
Cash Check# Total
$ Z1.
Payment
$
Balance
$ 7 -
Credit Card:
Type Exp. Date Card Number
fi X_earSubtetraneau Termite Retreatment Guarantee,• RP Lee Termite and Pest Control will retreat the structure for Subterranean
Termites at no cost to the customer, if an iufesffition of Subter=m'1c ites is. found, as long as. the original treatment.is_ mid in. full
and the customer is current on their yearly renewals. This Agreement will expire in one (1) year unless the customer elects to pay
the yearly warranty fee. The guarantee can be renewed for up to five (5) years by paying the yearly warranty fee. RP Lee Termite
and Pest Control may approve additional warranty years after the five (5) years with au additional increase in the yearly warranty fee.
The guarantee does not cover any damages to the structure or contents of the customer. The customer agrees to control all condusive.r
conditions that may cause reinfestation. If the structure is modified, added on to, altered, or if the soil treatment around the structure
is removed the customer must contact RP Lee Termite and Pest Control and pay for additional treatment in order to keep the guarantee
in effect. If the customer does not pay for additional treatment the retreatment guarantee can be cancelled. rye
Renewal Fee: Customer may elect to renew the ietreatment guarantee for additional years. The renewal fee is $ 15-0 . phis tax -
The renewal fee is due on or before the annual anniversary date or paid $' --I- plus tax every third (3) month with inspection.
IVlaintaininQ the Guarantee: The customer agrees to correct all condusive conditions, at owner's expense, as they exist or as they
occur in the future in order for the guarantee not to be cancelled Customer will make the structure available for inspections and
treatments as requested by RP Lee Termite and Pest Control.
Beiuscpection: RP Lee Termite and Pest Control will reinspect the structure at customers request or any other times RP Lee Termite
and Pest Control deems necessary. RP Lee Termite and Pest Control recommends that the customer call and set up an annual inspeo-
lion at the time of customers yearly renewal
ihin grijr,• This agreement maybe transferred to a new owner with the payment of a transfer fee of $ , copy of the Wood
Destroying Insect Report from the sell, and approval of RP Lee Termite and Pest ControL
This Subterranean Termite Retreatment Guarantee does not prevent and is not intended to control other forms of Te* mit- s
(prvwood Formosan etc.). Wood Boring Beetles Carpenter Ants Carpenter Bee Wood Rot hulgns DecaL or any other
wood destroying insects or organisms.
Arbitration: In the event of any dispute arising out of this agreement or any other services performed or not performed the parties
above agree to participate in mediation through and in accordance with the commercial mediation Hiles of the American Arbitration
Association. The Arbitrator shall consider the legal defenses raised in the arbitration, and the decision of the arbitrator shall be final,
binding, non -appealable and may be entered and enforced in any court having jurisdiction in accordance with the Federal Arbitration
Act
Limitation of Liability: Landscaping and grass next to the slab may be damaged during treatment, carpet may need to be pulled
up in certain areas around the home, drill holes may need to be made in floor coverings such as tile or linoleum or in cabinets next
to pipe areas, and holes may need to be cut in walls. Customer agrees not to hold RP Lee Termite and Pest Control liable for these
damages, or treatment techniques, or other damages that may occur during treatment
Agreement: This Agreement shall be the entire agreement between customer and RP LeeTeanite and Pest Control. If any part of
this agreement is found to be invalid it shall not affect the validity of any other part of the Agreement.
We are licensed by the Structural Pest Control Board 333-Guadalupe Suite I 5l0
Austin T% 78701512 3p5-8250
f. � � Y fi�v�'� �f`-� .,`,r?�` � S a v �- � � �� emu`✓ � �
RP Lee Terma& Pest Control Cert. Apl.# Customer Signature Date
From:STYLECRAFT BUILDERS INC 979 690 0348 12/03/2007 18:00 #620 P.006/007
SUBTERRANEAN-- TERMITE PRE -CONSTRUCTION; TREATMENT DISCLOSURE FOR'EACH ESTIMATE
Licensed and regulated under the Texas Structural Pest Control,
RP LEE TERMITE & PEST CONTROL
PO Box 9423 - College Station, TX 77842 - (972) 690-8622 - TPCL #11486
CUSTOMER INFORMATION:
Name: 4 Pc'r7 nr A ew56-- Phone #1:
Phone #2:
Address: City. w State: Zip Code:
Location to be Treated 1�� E R ST�
-----For-alltreatments.there will be a diagram sbowiagaxadty-wfiat-willbefreateOrkauothe beginningogmatmerd-Reviewthe.pestisideaabel providedtw ouat4hisfime for minimumtreatmentstandart
Remember that your architects or design englneers specifications must also be followed, unless they are in violation of the law. Review the consumer information sheet for further information. If Y
have any questions, contact the nest controtcomparnr or the Texas Structural Pest Coirh`ol Board, P.O. Box 1927, Austin, TX 78767-1927. Telephone number (512) 305-8250.
Before conducting a termite preconsttuction treatment, the company will present a complete diagram of the structure including construction details. When construction prevents performance of a f
trealmerd, in accordance with a bid for full treatment, any change to a partial treatment by the company providing the treatment wig be permitted lithe owner of the structure or the person in charge
the construction and the certfied applicator for the pest control company sign a statement attesting to the construction conditions. The agreement must be attached to the contract with an amend)
diagram showing the exact areas to be treated. Copies must be sent to the owner of the property within seven days of the application.
notes: O 2w., yr.4®
zVe-;55, rr c.r
�NT,¢Ec �,�ascd
Ave a !ice r
Type of treatment proposed: (check all that apply): ❑ Full kParlial IZWood ❑ Bait O Commercial 0 Wgle Family
Total square feet to be
treated: / Total linear feet to be treated: • to fl Approximate in of structure(s) to be treated:
A label of 1J 0,44 CA a <_ termiticide(s) Is attached. The percentage of the terrniticide(s) to be applied at this location is
Estimated amount of termtticide to be applied: aallonfsl.
THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE IS ATTACHED ON BACK (SPCBM 4). THE BOARD APPROVED SUBTERRANEAN TERMITE
PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUCTION TREATMENT
SERVICE Complete details of warranty (if any) including time period of warranty, renewal options and cost, and obfigations of the contracting parties is attached. If the warranty does not
include the entire structure treated, the area Included in the warranty are (specify):
A consumROnforination sheet is also attached, y
ITEM $STTit 3t4 owvor
Name Date Signature of Customer Verifying Receipt of Ths Document Date
While Copy- Service Provider Yellow Copy -Customer I— D-VM woftWbySa%mMikGm met-MV>B-15M,Dear,TX0=7
' Service Treatment Invoice
Route: Map Code:
PM
EDate:
f�'l. `' u� Appoint.Time:
am/ m
P
I Start Time: em/pm. Finish Time:
I Type of Service: ntd 'Regular ahapm
Frequency: M�
Structure: 1
BM Q S Y
Crawl P/B Combo
Follow Up One Time Charity
.0
Shielding & Protecting
Pets: Dog(s) Cat(s) Blyd(s) Fish
.AfGN e
j Service Address
Homes Against Posts"
}
°C
Name: ���i�/�'fi� v bea5� Billing:
TPCL #114"!
Cost of Service
$ ��
i Address: �E/1 Li ,t ^ l' ,�
Tax
$ —
Payment by:
City tt . 5 TX 77,E /3
Total Due
$ °
Cash Q
^
Phone:
Payment
$
Check O #
PEST PROBLEMS:
Balance
$ _ :
Credit Card U
I.
DIRECTIONS INSTRUCTIONS:
EQUIP. METH. LOCATION(S)
WOOD DESTRO NG INSECTS
GENERAL. PESTS
FLEAS
MICE, RODENT, RATS MONITORS
PRODUCT
QTY
TARGET PEST(S)
Termidor SC-Fipronfl.06% Subterranean Termites, Ants Size of Tank
Termidor 80W F1pronil.06%' _ �_ Posted
Subterranean Termites. Size of Tank. Posted
Bon-care.Disedium OctaborateTetrabydate 50% T Subterranean/FormosadDrywood Termites, Carpenter Ants, Beepes, Posted Advance-Balt-Abaneetin..011% Carpenter Ants
Invader HPH-Baygon 1%
Demon WP-Cyano-Phenoayphenyl
Dimet#ycyleyelopropanecarbozylate 1%
Tempo Ultra WP-Cynothtln .025% (Rest)
(gen. surface spray, spot, mist, crack & crevice)
Talker EZ BlfRnthrin 1%
Maxforce-Hydiamethylon l 0/o-2.15%
Cykick CS Cy9uthrin .05%
Phantom .5%
Tengard-Pergrethrin .5%
Suspend SC-Ddtaneturin 4.75°/Q (REST)
Nygum'd-Metbyletnoxy 10% (REST)
Excite R Pyrethrin .OS%
ltstrae-Brow ethaUn .01 %
Bait Station-LargelSman Glue. -Boards
Speckoz-Pyroclde .50%
Blfen 11T Blfenthrin .06W
kauiament: A -Compressed Snraver P_Pravor c.,ro.,-. u_n o. n:._-
CarpenterAnts, Spiders, Crickets, Ma 1pedes, Beetles, Termites.
Cockroaches, Millipedes, Suwbuga, Flies, Ticks, Mosquitos, Pillbugs,
Silverfish, Bees,Ants, Carpenter Acts, Scorpions, Spiders.
'Ants (Except Pharaoh), Cockroaches, Crickets, Earwigs, M1Wpedes, FUM Fruit Flies, Beetles,
PWbugs, Silverfish, Spiders, Gnats, Hornets, Wasps,YetiowJackets.
Ants, Centipedes, Cockroaches, Crickets, Grasshoppers, Scorpions, Ticks, Silverfish, Spiders.
Pharaoh Ants, Crickets, Carpenter Ants, Lg. Roaches, Variety of Ants:
Spiders, Scorpions.
Pbaroh Ants, Variety'ofAats, Roaches.
Fiea4lIcks,Ants, Centipedes, Carpenter Ants, Bees, Wasps, Carpenter Bees, Cockroaches,
Crickets, Flies, Earwigs, Millipedes, Beetles, Pillbugs.
Fleas, Bees, Beetles, Roaches, Crickets, Lice, Flies, Scorpions, Ticks, Wasps.
IGR-Growth Regulator -Fleas, Roaches, Crickets, Flying Insects, Stored Product Pests.
'Fleas.
Mice, Rodents, Rats
Mice, Rodents, Rats, Bug Monitors.
Houseflies, Mosquitos, Moths, Fleas, Wasps, Hornets, Ticks, Cockroaches.
Spiders, Ants, Roaches, Silverfish, Earwigs, Fleas, Scorpions
-_ +- - -• - i•� w,• --Pelt awuon in r -Dan Trap 11-Aerosol Can G-Glue Board PI -Hand Duster S-Spreader F-Fogger Other
IAt BtlOna: 1-Kitchen 2•Bath(s) 3-fledrooms 4-Dining Room 5-Utility 6 Stontge, "7,Common Areas 8-Garage 9-Perimeter of Stmcttae 10-Attic 11-Yard 12-Under Home 13-Warehouse 14.0ffice ISExposed Wood 2' up from Slab Other " &etUd of ImA men s: CC -Crack & Crevice SS -Sub -Slab injection VT -Void Treatment BP -Bait Placemenf BS-Broadcast'Spray PB�Perimeter Barrier BV-Brick Venire WT-Wood Treatment
PRECAUTIONS: Do, not touch treated areas till dry.'Do not tamper with bait stations. Ventilate rooms after treatment. Keep pets away until: pesticides have dried.
Licenced by the Structural Pest Control Board - 333 Guadalupe, Suite I-530 • Austin, TX '78701 's 512-305-8250.
I
§ERVICE TECHNICIAN: _ /i�c CUSTOMER SIGNATURE: ��ia S c,. �
—!7 5..--_
WF0988293 / 001 City of College Station
PAGE 1
REQ. DATE: 12/13/07 12/13/07 9:31:30
LOCATION: 2420 STONE CASTLE CIR LOC ID: 208156.
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 12/13/07 SCHED COMPLETION: 12/13/07
********************************************************************************
JOB ORDER RESULT COMMENTS
ti-
�' -r BUILDERS, INC.
Home, Less Money
SHEET INDEX
COVER SHEET
G-1
GENERAL NOTES
G-2
SITE PLAN
C-1
FOUNDATION -PLAN
S-1
DIMENSION PLAN
S-2
DETAILS
S-3
BRACING PLAN
S-4
FRAMING PLAN
S-5
ROOF FRAMING PLAN
S-6
DECKING LAYOUT
S-7
ELEVATIONS
S-8
FRAMING DETAILS
S-9
ELECTRICAL PLAN
E-1
FLOOR PLAN
A-1
FLOORING PLAN
A-2
CABINET LAYOUT
A-3
PLAN APPROVAL
APPROVED
INITIALS
DATE
ADMINISTRATOR
/
SUPERINTENDENT
/
CUSTOMER
/
NOTICE
THIS SET OF DRAWINGS FOR A HOME IS THE
COPYRIGHTED PROPERTY OF STYLECRAFT
BUILDERS, INC. THIS SINGLE COPY IS LICENSED AND
NO RIGHT TO REPRODUCE, COPY OR DUPLICATE ALL
OR ANY PORTION OF THE LICENSED PLANS IS
GRANTED, EITHER EXPRESSLY OR IMPLIED.
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THE DRAWING ARE
OWNED BY AND THE PROPERTY OF THE DESIGNERS
AND WERE CREATED, EVOLVED AND DEVELOPED
FOR USE ON AND IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS,
DESIGNS, ARRANGEMENTS OR PLANS SHALL BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR
CORPORATION FOR ANY PURPOSE WHATSOEVER
WITHOUT THE WRITTEN PERMISSION OF THE
DESIGNERS.
1 PLAN PREVIEW
SCALE:3/32"=1'-0"
FINISHING NOTES
1 lNotes
COMMENTS
LOCATION
7r
1
r— N
r
N
Ocl
cl
U�
�r
SHEET:
G-1
ZFRONT ELEVATION
SCALE:3/32"=1'-0"
AREA
SUMMARY
I ON F C RO NCE
Nd,, ---- g 10'REARP C7
Li
20' SETBACK I
----- -- - ------------
I
I
i
� � I
I
I UI
co Q
w� W I H
N� U) m
17'-6- _ t7-6w�"
I I
a p
o
0
I
0
5' RONT SETBAC o
I
C p Nl
2420 STONE CASTLE CIRCLE
CASTLEGATE 7
LOT -20
5' FRONT PUE —
BLOCK - 2
20 ssss - W5W8- PHASE - 1
a�
a
2420 STONE CASTLE CIRCLE
1 SITE PLAN
SCALE:1 "=20'-0"
A_
Fv
W€
zH
FTe
�g
SHEET:
C-1
STTE PLAN
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE 121TATIUN, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00003247 Date 11/06/07
Application pin number . . . 17013.9
Property Address . . . . . . 2420 STONE CASTLE CIR
Property ID: 184200-1720-0200
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . CASTLEGATE PH 1 SEC 7
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 191506
Owner Contractor
------------------------ ------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION TX 77845
(979) 690-1222
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE SIDING
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 3224.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TRAFFIC,.IMPACT ANAL (TAZ) 441.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit pin number . 533703
Permit Fee . . . . 736.00 Plan Check Fee .00
Issue Date . . . . 11/06/07 ,IValuation 191506
Expiration Date 5/04/08
Qty Unit Charge Per Extension
BASE FEE 460.00
92.00 3.0000 THOU BLDG, VAL 100001-500000 276.00
----------------------------------------------------------------------------
Special Notes and Comments
-Slab only permit #07-2932 was issued
-Make sure 2nd floor windows comply ' h 24" 2mTFz;;;
---------------------------------------- -------- ;------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 07-00003247 Date 11/06/07
Application pin number . . . 170139
----------------------------------------------------------------------------
Special Notes and Comments
-Add 2nd Floor smoke detector
-Narrow Wall Bracing Fully Sheathed with Outside Garage
Corner 18" Minimum APA Framed. Also Modified Master Bedroom
wall to get 32" minimum and Modified front door area with
interior anchor bolts and bracing.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 30") WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE -
----------------------------------------- -
BUILDING DEPT REPRESENTATIVE: ---- ---
APPLICANT: 1441- _117w m
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00003247
Application pin number . . . 170139
Page 3
Date 11/06/07
Special Notes and Comments
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK .I_S DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a g azing area that
exceeds 15% of the gross area of ex for Zis, -8Id t
--------------------------------------- --------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 07-00003247 Date 11/06/07
Application pin number . . . 170139
----------------------------------------------------------------------------
Special Notes and Comments
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT -OF" -WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 200
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC )
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE
ROOM.
ALL PLUMBING, ELECTRICAL, AND HVAC J(mehanica WORK MUS
BUILDING DEPT REPRESENWATIVE:_
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 5
Application Number . . . . . 07-00003247 Date 11/06/07
Application pin number . . . 170139
----------------------------------------------------------------------------
Special Notes and Comments
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total -- -- -- --
Plan Check Total
Grand Total
------------------------
BUILDING DEPT RE]
APPLICANT: e
V*
CITY OF COLLEGE STATION
Planning c5 Development Services
ADDRESS/LOCATION:
APPLICATION FOR BUILDING
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
I I For Office Use Only
PERMIT DATE: \ \TRCC REG
APPLICATION #
CirG4-
TEMP POLE #
LOT �,v BLOCK SUBDIVISION u S �t G 4�2 SEC/PH
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222�ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTACT PERSON FOR REVIEW COMMENTS: ERIC WIVAGG PHONE: 690-1222 ext. 120
FAX: 690-0348
+4i>.cv �-
ELECTRICIAN:
HVAC: Control Temp
EMAIL: ewivagg(aD_stylecraft-builders.com
PLUMBER: Bass Plumbing
GOOD CENTS (Residential only): No
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: Conventional Framing — L-C's s stm b
PROPOSED USE: Single Family Residence
WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/ CSPS �g ENGINEERED
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: No
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A
\(4LUATION: $ 19(,40 TOTAL AREA: 3g� HEATED AREA:
/ (Cost of at and Materials)
r• . PUBLIC SEWER NUMBER OF BEDROOMS:
I —I SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
SEWER TAP:
F_ WATER TAP:
❑ OTHER TAP:
L TEMP POLE
GARAGE TYPE
SIZE ` �0
SIZE
INTERIOR WALL TYPE: Sheet Rock
D a'+
EXTERIOR WALL TYPE: Siding and/or Masonry
FOUNDATION TYPE: Slab on Grade
NZE
ROOF TYPE:
SINGLE DOUBLE
ATTACHED DETACHED
Composition
TRIPLE 71
CARPORT
SIGNATURE OF APPLICANT: — %-- For Stylecraft
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
/1-7--07
�F�10 Plans Examiner D Zoning Official
Co ments:
� r ✓� -/-S ES or NO
Fire Marshall
A " Op
Energy Code Compliance Information
% Glazing of exterior walls `� 3 %
Insulation R value of exterior walls R13
Insulation R value of ceiling 1 (flat areas) Rs' 3.8 `
Insulation R value of ceiling 2 (vaulted areas/no attic) R19
Glazing SHGC (Solar Heat Gain Coefficient) .35
Glazing U-Factor .53
R value of ductwork R6
A/C SEER Rating 13
Protection Against Subterranean Termites
❑ Chemical Termiticide Treatment (Soil Treatment)
Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
i
' � 1
t V*. tlq"
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# O n _ 3 a
DATE:
BUILDING ADDRESS: �yg-4) ' • _
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
WJOK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
MOK
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within T of property line to have protected openings.
&W10K
OK
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
III. Stairway Requirements
A. Stairway Details
N
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
CITY OF COLLEGE STATION
Planning 6 Development Servial
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NA/ K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
7
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
&90 K
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLAN5 EXAMINER
DATE
REScheck Software Version 4.0.1
Compliance Certificate
Project Title: 2350 Plan
Report Date: 11/01/07
Data filename: \\STYLECRAFTI\Share\ACAD\RESCheck\2350.00-Master.rck
Energy Code:
2006 IECC
Location:
College Station, Texas
Construction Type:
Single Family
Conditioned Floor Area:
3224 ft2
Glazing Area Percentage:
21 %
Heating Degree Days:
1788
Climate Zone:
2
Construction Site:
College Station, TX 77845
Owner/Agent:
Stylecraft Builders, Inc.
4090 SH 6 South
College Station, TX 77845
979-690-1222 x120
ewivagg@stylecraft-builders.com
Designer/Contractor:
Stylecraft Builders, Inc.
4090 SH 6 South
College Station, TX 77845
979-690-1222 x120
ewivagg@stylecraft-builders.com
Maximum SHGC: Your SHGC: 0.40
0.40
Wall 1: Wood Frame, 16" o.c.:
2486 13.0
0.0 159
Window 1: Metal Frame:Double Pane with Low-E:
492
0.67u 330
SHGC: 0.40
Door 1: Solid:
38
0.500 19
Door 2: Glass:
18
0.440 8
SHGC: 0.40
Ceiling 1: Flat Ceiling or Scissor Truss:
3001 38.0
0.0 90
Floor 1: Slab -On -Grade: Unheated:
223
0.0 232
Insulation depth: 0.0'
Furnace 1: Forced Hot Air: 80 AFUE
Air Conditioner 1: Electric Central Air: 13 SEER
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2006 IECC requirements in
REScheck Version 4.0.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name - Title Signature Date
Project Notes:
All U-Factors and SHGC are at entered at higher than actual amounts.
Actual amounts are lower, but are entered higher to account for
differences in ratings per material.
2350 Plan
Page 1 of 1