Loading...
HomeMy WebLinkAboutSIGN2007-03010p 1.3010 YP., PREPARED 10/31/08, 12:05:03 INSPECTION TICKET PAGE 1 _C ity of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/31/08 ------------------------------------------------------------------------------------------------ `vADDRESS 801 TURTLE DOVE TRL SUBDIV: CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER PHONE :-.,PARCEL 230100-0130-0080 uAPPL NUMBER: 07-00003008 RESIDENTIAL, 1 UNIT DETACHED NEW :.------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT t REQUESTED INSP DESCRIPTION ' TYP/SQ COMPLETED RESULT RESULTS/COMMENTS g- ------------------------------------- ----------------------------------------------------------- 01 B100 01 B120 01 B115 01 B 131 01 11/26/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 11/26/07 AP November 26, 2007 9:48:50 AM kwolfe. 11/26/2007 03:34 PM RH PDA Strings up''slab ground installed. 12/19/07 RH BLDG, FRAMING -PARTIAL TIME: 17:00 12/19/07 AP December 19„ 2007 9:31:07 AM kwolfe. APA FRAMING`-1 December 19; 2007 11:55:41 AM kwolfe. 3/14/08 RH BLDG, FRAMING TIME: 17:00 3/14/08 AE March 13, 2008 4:50:14 PM kwolfe. March 14, 2008 11:48:38 AM kwolfe. need anchors'at doors do not brace off of stiffback at area above citchen tape seal tyvek and holes 3/25/08 BB BLDG, INSULATION TIME: 17:00 3/25/08 DP March 24,' 2008 3:44:27 PM glsouth. afternoon 03/25/2008 04:56 PM BB PDA Need anchors at doors. Need to tape seal penetrations and loose Tyvek. B130 02 3/28/08.: BB `:•;:' `BLDG, INSULATION TIME: 17:00 3/28/08 AP March 27, 2008 8:01:21 AM kwolfe. insulation B125 01 10/31/08 ',�BII BLDG, FINAL TIME: 17:00 October 31, 2008 10:14:31 AM bcaldwell. ---------------------------------- COMMENTS AND NOTES --------- --------------------------- us<<�5� .. y WF0975169 / 001 City of College ijt_t;on PAGE 1 REQ. DATE: 10/18/07 10/18/07 14:10:50 LOCATION: 801 TURTLE DOVE TRL LOC ID: 205504 REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/18/07 SCHED COMPLETION: 10/18/07 JOB ORDER RESULT COMMENTS 11/04/2008 16:00 9797740565 ED FROEHLING BUILDER PAGE 02/04 TEXAS SPC13 TERMITE TREATMENT DISCLOSURE DOCUMENT ProRerri _-0—w- ea FROEHLING HOMES Locafipjutp-?e Treate-& 801 TURTLE DOVE Apj?roX#mate Mu���.��TICe tamed= 2119 peEc to71 GAS.MtjgTrt�U- TxRgs f atment- Vert od M - Horizontal/Perlmeter Beam--? X — -� ' II 11 , !IF, i . • . • I • • L r �e1 of Ta#star O�.e�a���lidt�L�#a�e.�i�ed as oarx�f th#s docume��t„ A LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY) INCLUDING AREA COVERED, TIME PERIOD OK WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATION3 OF THE PEST CONTROL OPERATOR TO RE. TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOib THE WARRANTY HAS ALSO BEEN ATTACHED. Charges for pre -treat: $309.59 NOTES: Annual re-newal: $125.00 32129 PT 11/21/2007 Ca or TocHticim GPM 11cor o 0 =' 1m PT 11/04/2008 16:00 9797740565 ED FROEHLING BUILDER PAGE 03/04 ACE PEST CONTROL T.P.C.L. # 7120 PT PO BOX 4474 BRYAN, TX 77805 (979) 823-7777 (979) 7144736 CERTIFICATE The following property OI TU)[tTLE DdVE built by FROEHLTNG IFTOMES _„State of Texas County of BBRAZOS the city of COLLEGE STAT>GON Mailing Address SAME Zip code 77845 was treated for subterranean termites on this day N031AMER 21, 2007 and has met with approval.. Cost of initial treatment, 30$ 9.59� is payable upon completion, of work. The treatment is guaranteed for 12 months from the date of treatment. Thereafter, this contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection and renewal. fee of x_S 25 ^plus tax, for a period of� 4 years. ( see attached letter ) I£ at any titre during this contract a reinfestation of subterranean termites should occur, the above said property will be treated at no additional cost to the owner. ACE PEST CONTROL does not accept any liability for any subterranean termite damage repair. Failure to pay the annual renewal. fee within thirty days after the inspection. date sball be construed as a cancellation of this contract. Any alteration or addition to the foundation of the above described property without proper termite treatment by ACE PEST CONTROL Services shall. nullify this contract. Licensed and Regulated by the Texas Department of Agriculture, Structural Pest Control Service, PO Box 12847, Austin, Texes 78711-2947 (512)305-8250 11/04/2008 16:00 9797740565 ED FROEHLING BUILDER PAGE 04/04 SUBTERRANEAN TERMITE PRECONSTRUCTION ]DISCLOSURE FOR EACH ESTIMATE For all treatments there will be a diagram showing exactly what will be treated prior to the beginning of. treatment. Review the pesticide label provided to you at this time for m.in.imum treatment standards. Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the law. Review the consumer information sheet for further information. If you have any questions, contact the pest control company or the Texas Structural Pest Control Board, PO Box 1927, Austin, Texas 78767-1927_ Telephone number (512) 305-8250. . Name of Customer Address city State lip Location to be Treated Type of TreatmentFull A label The percentage of the termiticide(s) to be applied at this location is iticide(s) is enclosed. (Warranty .information provided ,roust include the Complete Details of any Warranty provided and the following: 7Yme Period of Warranty; .renewal Options and Cost; and Obligations of the Contracting Parties if the warranty does not include the entire structure treated, the areas included in the warranty are: (specify) Total Square feet to be Treated: 11d Total Linear Feet to be Treated: Approximate Measurenaeots of the Structure(s) to be Treated: vcw� ` ", Sign�at ire of Certified Applicator or Printed Name f Vale Technic'an Completing Est3,-� e �0 712W-r- Name of Pest Control Company TPCL. No. Licensed and regulated under the Texas Structural Pest Control Act Texas Structural Pest Control Hoard, PO Box 1927; Austin, Tw ias 78767-1927, Telephone number (512) 305-8250. Sample Form — April 4, 2005 Page 1 of 2 BUILDING PERMIT CITY OF CbLLEG'E STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number 07-00003008 Date 10/18/07 Application pin number . . . 145408 Property Address . . . . . . 801 TURTLE DOVE TRL Property ID: 230100-0130-0080 R #: R Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 153978 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2333.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TRAFFIC.IMPACT ANAL (TAZ) 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 530675 Permit Fee . . . . 622.00 Plan Check Fee .00 Issue Date . . . . 10/18/07 Valuation . . . . 153978 Expiration Date . . 4/15/08 Qty Unit Charge Per Extension BASE FEE 460:00 54.00 3.0000 THOU BLDG, VAL 100001-500000 162.00 ---------------------------------------------------------------------------- Special Notes and Comments -Narrow Wall Bracing Fully Sheathed with 16" Minimum APA. Garage Framing. _ ---------------------------------------------- BUILDING DEPT REPRESENTATIVE: -----�---------- APPLICANT: i���l BUILDING PERMIT CITY OF COLLEGt STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 07-00003008 Date 10/18/07 Application pin number . . . 145408 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. Garage ceiling must have 5/8" Type X sheetrock when there is Habitable space above the garage. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN TWENTY FEET (20') OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O06 INT RNATIONAL RESIDENTIAL -------------------------------- ------ - - ---.------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGt STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00003008 Date 10/18/07 Application pin number . . . 145408 ---------------------------------------------------------------------------- Special Notes and Comments CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/.EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVI ED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 -- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGt STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00003008 Application pin number . . . 145408 Page 4 Date 10/18/07 Special Notes and Comments RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 200 TO 30% A .35 FACTO OR LOWER SHALL BE MET. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING ---------------------------'= -- --- ----- ---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number 07-00003008 Date 10/18/07 Application pin number . . . 145408 ---------------------------------------------------------------------------- Special Notes and Comments EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) ' RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE ROOM. ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ---------------------------------------- Due ----------------- Permit Fee Total 622.00 622.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1372.00 1372.00 .00 .00 ----------------------- - - - - -- ---- _... BUILDING DEPT REPRESENTATIVE:.,:,. v APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning d Drvelapmrnt Serviun WWW.CSTX.GOV ADDRESS/LOCATION: LOT 8 V BLOCK I_-rt `Tr4o;1 ✓ DATE: J0 I M791EG APPLICATION # 07ao It TEMP POLE # 3 SUBDIVISION 'OOVP/ �_ GrOSS 1 �/1G�✓ SEC/PH 1 Ci ✓ BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: 1 G. PHONE: CONTACT PERSON FOR REVIEW COMMENTS: M ax-k PHONE: 7 6-9 ZG6 FAX: 40 2f-77' 66,, 5 5 ELECTRICIAN: T"t `.n7 C lC/14c% & V HVAC: (A 1 Y1Vt©VXA.yQ. EMAIL: ./ PLUMBER: `T• �� GOOD CENTS (Residential only): ACCESSORY/STORAGE MOVING RE -ROOF ADDITION EW CONSTRUCTION" SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION REMODELJRENOVATION* DESCRIPTION OF WORK: PROPOSED USE: STRUCTURE USE: ;I HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TT ROJECT REGISTRATIOnN# EABPRJ VALUATION: $ IVD-.27 '9 9 1J TOTAL AREA: 47 HEATED AREA: Z 3 (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: SIZE WATER TAP: 3 4 SIZE OTHER TAP: SIZE TEMP POLE NUMBER OF BEDROOMS: 4- NUMBER OF BATHROOMS: 3 INTERIOR WALL TYPE: SA"'&4 IVA. EXTERIOR WALL TYPE FOUNDATION TYPE ROOF TYPE: GARAGE TYPE: SINGLE F__j DOUBLE d ATTACHED DETACHED +.��rr1 A. fl TRIPLE CARPORT SIGNATURE OF APPLICANT: If proposed work involves new commercial construction or facade im ents/renovations to an existing commercial property, building elevations are required. ............................................................ Official Use Only ' Co 0 � 1 1 � 1 Comments: ES r NO �'C iv Plans Examiner 4, 4t (off" ZY I'ApF- Zoning Official -&44 v Ily Shr.,i d W//W GAAAfe AA,k.>>j 16"MtN. r Energy Code Compliance Information % Glazing of exterior walls = �O Insulation R value of exterior walls i3 Insulation R value of ceiling 1 (flat areas) 30 Insulation R value of ceiling 2 (vaulted'areas/no attic) N/A ✓ -s Glazing SHGC (Solar Heat Gain Coefficient) • �� Glazing U-Factor t • �04 '✓ R value of ductwork A/C SEER Rating 13 Protection Against Subterranean Termites Chemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. Q c a� J E m 3 `° a O _ N Z t o Q � o o L0 Dove Crossing Subdivision Scale: 1 " = 20' 10' P.U.E.-- ---- (IC F- ..I j5'-0" 39'-6" B.S.L. �---� 62'-0" — 39'-0" 801 Turtle Dove Trail Proposed LO v Residence Phase 1 C Lot 8 Block 3 in ELEC BOX V FROM CORNER I Concvete I \ O J I .. . 'Driveway.', • ' .'' I N 5' P.U.E. Turtle Dove Trail 50' R.O.W. •- 27' Pavement CITY OF COLLEGE STATION Planning & Dr Iopmmt $nvirn PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: BUILDING ADDRESS: poi U1 ,e Dvve I P % . I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex K 1. One -hour rated extending to roof deck"OKI E. Header sizes indicated on plans NAA0K F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not rovided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans t CITY OF COLLEGE STATION Planning 6 Development Strviat PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OWOK WOK A. Stairway Details NA/ 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required CITY OF COLLEGE STATION Planning 6- Development Semitet PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/ A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NAtOA Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed 1-1 Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed WO-K:: "APPROVED PLANS PER IRC SECTION R106.3.1." CITY OF COLLEGE STATION Planning d Development Snvitei PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS ALL PLANS EXAMINER CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX /0-11-o7 DATE REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\80 I TD.rck TITLE: 801 TURTLE DOVE TRAIL CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 10/ 10/07 DATE OF PLANS: 10/5/07 PROJECT INFORMATION: LOT 8 BLOCK 3 DOVE CROSSING I COMPANY INFORMATION: ED FROEHLING BUILDER, INC. COMPLIANCE: Passes Maximum UA = 867 Your Home UA = 612 29.4% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.36 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window I: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Front Projection factor: 0.33 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Left Side Projection factor: 0.33 Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Back Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1572 30.0 0.0 55 761 30.0 0.0 27 312 13.0 0.0 21 21 0.640 13 38 0.400 15 434 13.0 0.0 30 73 0.640 47 312 13.0 0.0 23 19 0.640 12 Projection factor: 0.33 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 135 deg. from North; Comp. orient.: Back Projection factor: 0.33 Wall 4: Wood Frame, 16" o.c. 434 13.0 0.0 32 Window 4: Metal Frame:Double Pane with Low-E 43 0.640 27 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Right Side Projection factor: 0.33 Wall 5: Wood Frame, 16" o.c. 261 13.0 0.0 21 Wall 6: Wood Frame, 16" o.c. 220 13.0 0.0 16 Window 5: Metal Frame:Double Pane with Low-E 25 0.640 16 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Left Side Projection factor: 0.33 Wall 7: Wood Frame, 16" o.c. 261 13.0 0.0 21 Wall 8: Wood Frame, 16" o.c. 220 13.0 0.0 16 Window 6: Metal Frame:Double Pane with Low-E 25 0.640 16 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Right Side Projection factor: 0.33 Floor 1: Slab -On -Grade: Unheated 186 0.0 194 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 13 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in the RES check Inspection Checklist. Builder/Designer Date