HomeMy WebLinkAboutRES2007-02902, 07-2903O/v 7, o o ol, 0,5 Clem P PREPARED 8/19/08, 8:05:19 INSPECTION TICKET PAGE 4 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/18/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 4413 AMBERLEY PL SUBDIV: CASTLEGATE PH 6 CONTRACTOR PODRAZA CUSTOM BUILDERS, INC PHONE (979) 690-3810 OWNER PODRAZA CUSTOM BUILDERS INC PHONE PARCEL 184200-0601-0040 APPL NUMBER: 07-00002902 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT= BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 10/30/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 10/30/07 AP October 29, 2007 4:46:00 PM kwolfe. 10/30/2007 10:46 AM RH PDA Strings up, slab ground installed. B120 01 12/20/07 RH BLDG, FRAMING -PARTIAL TIME: 17:00 12/20/07 AP December 20, 2007 8:51:13 AM glsouth. APA FRAME _ B115 01 2/20/08 OC BLDG, FRAMING TIME: 17:00 2/20/08 AP February 20, 2008 11:12:29 AM kwolfe. B130 01. 2/26/08 RH BLDG, INSULATION TIME: 17:00 2/26/08 AP February 25, 2008 4:03:29 PM glsouth. B125 01 8/18/08 BI BLDG, FINAL TIME: 17:00 A�e August 18, 2008 4:43:19 PM ccourt. ----------------------------------- CONTINUED ONTO NEXT PAGE ----------------------------------- Ajee '� 'I l. ?vs' !aiL7ZGl TL_.cam 0 tjo+ bww oJ'r AtiiJ-�.c- (8/19/2008) Bethany Boerboom Re Calling for CO for 4413 AmberleyvPlm _ .__ __ Page ! ' �_.....:---:._.. .. �..------.-.--.---- ___ _.__.�__ From: Paul Schoenfeld To: Benjamin McCarty; Bethany Boerboom; Chris Haver; Gina Southerland; I... Date: 8/19/2008 12:24 PM Subject: Re: Calling for CO for 4413 Amberley PI ALL OK. PAUL >>> Bethany Boerboom 8/19/2008 8:21 AM >>> BP 07-2902 Any issues? Beth Boerboom, Customer Service Rep. Planning & Development Services City of College Station 979.764.3570 www.cstx.4ov WF0974037 / 001 City of College Statiorl PAGE 1 REQ. DATE: 10/15/07 10/15/07 10:21:43 LOCATION: 4413 AMBERLEY PL LOC ID: 204278 REQUESTOR: PODRAZA CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/15/07 SCHED COMPLETION: 10/15/07 ******************************************************************************** JOB ORDER RESULT COMMENTS a. City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 8/21/08 Parcel Number . . . . . 184200-0001-0040 Property Address . . . 4413 AMBERLEY PL COLLEGE STATION TX 77845 Subdivision Name CASTLEGATE PH G Legal Description . . . CASTLEGATE SEC 6, BLOCK 1, LOT 4 Property Zoning . . . . PLANNED DEVL DISTRICT Owner . . . . . . . . . PODRAZA CUSTOM BUILDERS INC Contractor . . . . . . PODRAZA CUSTOM BUILDERS, INC 979 G90-3810 Application number 07-00002902 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . Approved . . . . . . . Bu' ing Official VOID UNLESS SIGNED BY BUILDING OFFICIAL TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT q . \'.. t'Am o b�_� Location � rated. 4��";�„'�q.:ti.� .:'r,-<SR+ '""ss,n-f 5'•o5 �;cti".;?C'�''("-,'"?� .yf���:` _! ARproxamate Measures to be T abed. Percentage of ❑ ill • - l • • _ applied at this locationsType of Treatment Full -.l. Pri A LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS SEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY) INCLUDING AREA COVERED. TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE- TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOLAD VOID THE WARRANTY HAS ALSO BEEN ATTACHED. i:i?C%J j;,`�'+< v,(:.t�i� ,.�� y.ss.a f; .:a� Charges for iP� re -treat: :x�$�>Ys=$5°' P I�.i . ,1, ,..at..,. r�3::t.:'ttitd.L+. v. asilu•..c..a„r:.. r n:.>rFt NOTES: Annual re-newal:-y? R 1l. ' :...:5_-:'i'v5...::..J�..`:f :.•.-INt.�".`{-:(�:1.1•:: !i..s..5 sv::Gl s-. ..¢....s :r Ca or TeMindan SPCB Brume 6 S212S PT z'd 099B-S26-9E6 'siapjing wo4sn0 eze.apod �,S=B Boot Oz 2nd ACE PEST CONTROL PO BOX 4474 BRYAN, TX 77805 (979) 823-7777 TPCL 7120 PT LIMITATIONS OF LIABILITY 1. ACE PEST CONTROL'S liability for additional treatment of the covered property is limited to areas of infestation to the structure(s) which occur during the term of this agreement (with the restrictions of the chemical label). 2. ACE PEST CONTROL shall not be liable for property that has been added to or structurally altered unless ACE PEST CONTROL has been notified prior to the beginning of any additions or alterations, and any additional treatment or re -treatment found necessary is performed. Such additional treatment must be performed by ACE PEST CONTROL at the expense of the owner. 3. ACE PEST CONTROL shall have no liability under this agreement should the customer refuse access to the covered premises of any additions for the purpose of carrying out the terms and conditions of the agreement. 4. ACE PEST CONTROL shall not be liable for re -treatment of subterranean termite infestation caused by ABNORMAL moisture conditions such as leaky roofs, shower stalls, plumbing, or wet soil under the structure due to poor ventilation. . 5. This service agreement does not guarantee against present or future damage to property or contents, nor provide for repairs or compensation therefore. This service agreement is for subterranean termites only, and does not include treatment for dry - wood termites, carpenter ants, powder post beetles, or other wood destroying insects. 6. ACE PEST CONTROL shall not be liable for re -treatments of subterranean termites caused by excess wood left around the foundation. For example: wood forms, railroad ties, or any excess wood forms left in tub drains. Licensed and regulated by the Structural Pest Control Board P.O. Box 1927 Austin, Texas . 78767-1927 (512) 305-8250 6-d 0996-S28-966 `sjopjtng wogsn0 ezeJpod *Is: a' 800202 end ACE PEST CONTROL T.P.C.L. # 7120 PT PO BOX 4474 BRYAN, TX 77805 (979) 823-7777 (979)774-4736 CERTIFICATE The following property 4413 AMBERLEY PL. built by PODRAZA CUSTOM HOMES State of Texas County of BRAZOS the city of COLLEGE STATION Mailing Address SAME Zip code 77845 was treated for subterranean termites on this day OCTOBER 27, 2007 and has met with approval. Cost of initial treatment, $524.25, is payable upon completion of work. The treatment is guaranteed for 12 months from the date of treatment. Thereafter, this contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection and renewal fee of $ 140 plus tax, for a period of 4 years. ( see attached letter ) If at any time during this contract a reinfestation of subterranean termites should occur, the above said property will be treated at no additional cost to the owner. ACE PEST CONTROL does not accept any liability for. any subterranean termite damage repair. Failure. to pay the annual renewal fee within thirty days after the inspection date shall be construed as a cancellation of this contract. Any alteration or addition to the foundation of the above described property without proper termite treatment by ACE PEST CONTROL Services shall nullify this contract. Licensed and regulated by Structural Pest Control Board P.O. BOX 1927 Austin, TX 78767-1927 (512) 305-8250 b'd 09SB-SZB-9E6 `siapjing wogsn0 ezeJpod tS=B 8002 02 2nd CONSUMER INFORMATION SHEET The structural pest control industry is regulated by the Texas Structural Pest Control Board located at PO Box 1927, Austin, TX 78767-1927. The Board licenses the businesses, certified applicators and technicians who perform structural pest control work. Certified applicators and technicians must pass a written examination in order to receive their licenses. Pesticides must be registered with the United States Environmental Protection Agency and the Texas Department of Agriculture before they may be used in Texas. Environmental Protection Agency registration is not a fmding of product safety. Pesticides are designed to kill or control pests. Your risk of harm depends upon the degree of your exposure and your individual susceptibility. Specific health and safety information varies between pesticides and types of exposures and is available on the label information or MSDS sheet, which can be supplied to you upon request from the licensed applicator. Take precautions when a treatment has been performed to avoid exposure to vulnerable individuals. Pesticides may be harmful if swallowed, inhaled, or absorbed through the skin. Avoid breathing dust or spray mist and any unnecessary contact with treated surfaces. If you desire specific information on precautions, refer to the pesticide label. The law requires that the application procedures specified on the label be followed. If you have questions about the application, contact the business or person making the application. If you suspect a violation of the law regarding structural pest control, contact the Structural Pest Control Board. In case of a health emergency, seek immediate medical attention. Pest Control signs must be posted prior to treatment in many instances. The signs should be posted in an area of common access at least 48 hours prior to treatment. The information sign will allow you to contact someone who can tell you what pesticide is being used. If you are contracting for pest control services due to a home solicitation, you have the right to cancel the contract within 72 hours. You may exercise this right by notifying the pest control company that you do not wish to receive their service. For general information on pesticides contact the National Pesticide Telecommunications Network at 1-800-858-7378. For information concerning structural pest control laws, contact the Structural Pest Control Board at (512) 305-8250. For information concerning the. formulation and registration of pesticides, contact the Texas Department of Agriculture at (512) 463-7476. For non -emergency health information relating to pesticides, contact Texas Department of Health (512) 458-7111 REDUCED IMPACT SERVICE In order to minimize the reliance on pesticides and reduce pest populations, a Reduced impact Pest Control operator may recommend that you consider the sanitation or physical alteration of your work place or residence. It is your responsibility to follow those recommendations. Your pest control operator may or may not offer these services upon request. A proper inspection will provide the information necessary for you to choose the method of pest control which best suits your situation. Many pest problems can be solved without using pesticides. This Reduced Impact Service will include an inspection report and treatment recommendations. You should review these and keep a copy for your records. Your cooperation in following the recommendations made by your service provider is essential to a reduced impact service program. Pesticides may be used in a responsible and professional manner in a reduced impact pest control service. If you do not want a specific pesticide used or any pesticides used at all, you must note this in writing on the contract prior to the initiation of the service. If any specific pesticide or class of pesticides are not excluded, it may be used by the provider. REQUIRED BY THE TEXAS STRUCTURAL PEST CONTROL BOARD Revised 6/6/03 Pagel of 1 S'd 0998-S28-9E6 `sjoPling wojsn0 ezeipod ts:a 800Z oa 2nd SUBTERRANEAN TERMITE PRECONSTRUCTION DISCLOSURE FOR EACH ESTIMATE For all treatments there will be a diagram showing exactly what will be treated prior to the beginning of treatment. Review the pesticide label provided to you at this time for minimum treatment standards. Remember that your architects or design engineers specifications. must also be followed, unless they are in violation of the law. Review the consumer information sheet for further. information. If you have any questions, contact the pest control company or the Texas Structural Pest Control Board, PO Box 1927, Austin, Texas 78767-1927. Telephone number (512) 305-8250. C. Name of Customer s4o�_ Address- city State Zip A Location to be Treated � ( G 5 zi � Type of Treatment: [ ] Full ¢Partial A label of�- termiticide(s) is enclosed. The percentage of the termiticide(s) to be applied at this location. is Warranty Information provided must include the Complete Details of any Warranty provided and the following: Time Period of Warranty; Renewal Options and Cost; and Obligations of the Contracting Parties. If the warranty does not include the entire structure treated, the areas included in the warranty are: (specify) Total Square Feet to be Treated: 3 7 2— Co Total Linear Feet to be Treated: Approximate Measu ents of the Structu ) to be Treated: li V� � O� •v S V C� Gq l S Signature of Certified Applicator or Technici Co pie ' Estimate Name of Pest Control Company Printed Name - Date TPCL. No. i / z_1D y0 T Licensed and regulated under the Texas Structural Pest Control Act Texas Structural Pest Control Board, PO Box 1927, Austin, Texas 78767-1927, Telephone number (512) 305-8250. Sample Form —April 4, 2005 Page 1 of 9-01 09SB-SZB-9E6 `siapjing wojsn0 eze,apod bS=B 8002 02 2nd SUBTERRANEAN TERMITE PRECONSTRUCTION DISCLOSURE FOR EACH ESTIMATE For all treatments there will be a diagram showing exactly what will be treated prior to the beginning of treatment. Review the pesticide label provided to you at this time for minimum treatment standards. Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the law. Review the consumer information sheet for further information. If you have any questions, contact the pest control company or the Texas Structural Pest Control Board, P.O. Box 1927, Austin, TX 78767-1927. Telephone number is (512) 305-8250. Name of Customer: Podraza Custom Homes ,Location Name: Property Owner Customer Address: P.O. Box 10107 Location to Treat: 4413 Amberly Place College Station, TX 77842 College Station, TX 77845 Type of Treatment [ ] Full [ ] Partial [X] Wood [ J Bait [ ] Commercial [X] Single Family A label of Bora-Care Termiticide(s) is enclosed. The percentage of the termiticide(s) to be applied at this location is: 23.0% Warranty Information provided must include the Complete Details of any Warranty provided and the following: Time Period of Warranty; Renewal Options and Cost; and Obligations of the Contracting Parties. If the warranty does not include the entire structure treated, the areas included in the warranty are: (specify) Total Square Feet to be Treated: 3726 Total Linear Feet to be Treated: Approximate Measurements of the Structure(s) to be Treated: A%W" 6 a 6 Russell C. Breland 633 02/14/2008 Signature of Certified Applicator or Printed Name Date Technician Completing Estimate A-1 Termites TPCL 11932 Name of Pest Control Company TPCL. No. Licensed and regulated under the Texas Structural Pest Control Act Texas Structural Pest Control Board, PO Box 1927, Austin, Texas 78767-1927, Telephone number (512) 305-8250. Page 1 of 4 1--d 09913-S28-9E6 `siapjtng wojsn0 ezeJpod SS=B 8000 02 2nd A-1 Termites 979-589-1203 Ofic.979-589-3655 Fax 7343 Wixon Road. P.O. Box 5481 . Bryan, TX 77805 TPCL 11932 LIFETIME SUBTERRANEAN TERMITE CONTRACT Contractor Name: Podraza Custom Homes Property Name: Property Owner Contractor Address: P.O. Box 10107 Property Address: 4413 Amberly Place College Station, TX77942 College Station, TX 77845 Property Description: Residence - Bora Care Wood Pretreatment for Subterranean Termites Effective: 02/14/2008 through 02/14/2010 Treatment Cost: $O.OD Yearly Renewal: $250.00 + tax = $26938 Treatment Areas: [X] 2' High Interior Wall Studs [ j 8' High Interior Wall Studs [ [ 2' High Exterior Wall Transfer Cost: $150.00 (Charged to Buyer after sale of Property) A-1 Termites will annually extend this contract to the Owner for the LIFETIME of the property provided the yearly renewal is paid before the end of the previous contract period. If active subterranean termite infestation is found while under contract, A-1 Termites will retreat the infested area at no charge. If the property sells,. the new Owner must pay the transfer cost and yearly renewal or the contract is void. A-] Termites reserves the right to revise the annual renewal charge after the first year and each year after that. A-1 Termites does NOT guarantee against any present or future damage to this property or its contents, nor will A-1 Termites provide for any repairs that may be necessary. Any additions or alterations to the property drawn on the graph/blueprints dated 02/14/2008 will allow A -I Termites the right to change the amount of the annual renewal. A-1 Termites must be notified of these changes, and the additions or alterations must be properly treated by A-1 Termites at the expense of the Owner, or this contract is invalid. Po raze C m homes Date Russell C. Breland C.A. for A-1 Termites Licensed and Regulated by the Structural Pest Control Board P.O. Box 1927, Austin, TX 78767-1927 512-305-8250 Page 3 of 4 B-d 0998-SZB-9E6 `stapling wolsn0 ezeipod SS=B BOOz OZ `end PROPER PRE -CONSTRUCTION SUBTERRANEAN TERMITE TREATMENTS A Guide for Builders and Consumers I. Definitions The Texas Structural Pest Control Board licenses pest control operators and regulates the application of pesticides for the prevention or control of subterranean termites. Because of the importance of treatments made to buildings under construction (commonly called pre -treats), this publication has been prepared for builders and consumers which hire pest control operators for these preventative termite treatments. Pre -construction treatments may include soil treatments, baiting systems, treatments of wooden structural elements, physical barriers, methods and other devices. A pre -construction liquid soil termiticide treatment may be a full treatment or a partial treatment, defined in the following manner. A. FULL TREATMENT Effective precodstruction treatment for subterranean termite prevention requires the establishment of complete vertical and horizontal approved physical or chemical barriers between wood in the structure and the termite colonies in the soil. For Horizontal Chemical Barriers, applications shall be made using a low pressure spray after grading is completed and prior to the pouring of the slab or footing to provide thorough 01108120D7 Texas Structural Pest Control Board P.O. Box 1927 Austin, Texas 78767-1927 Telephone No. (512) 305-8250 and continuous coverage of the area being treated. For Vertical Chemical Barriers, establish vertical barriers in areas such as around the base of foundations, plumbing lines, backfilled soil against foundation walls and other areas which may warrant more than just a horizontal barrier. B. PARTIAL TREATMENT A partial treatment is anything less than a full treatment as described above. A partial treatment only protects the areas treated from wood destroying insects. The areas chemically treated must be treated using at least the minimum labeled rate. Physical barriers and devices installed at slab penetrations are considered partial treatments. Baits shall be disclosed as bait treatments. C. PRE -CONSTRUCTION TREATMENT WITH WOOD FRAMING A pre -construction treatment of all or part of the wood framing as described in Board Rul 599.3(e) shall be disclosed as a wood treatment. Label instructions for.wood framing treatments allow a wide variety of treatment strategies. More extensive treatments may provide greater protection than treatments designed to protect a specific area or location. II. APPLICATION RATES Labels can and do differ. Read and follow label directions. Builders and consumers should ask for a copy of the label. 1) Unless otherwise directed by the label, fill material to be covered by a slab is treated at a rate of 1 gallon per 10 square feet (soil fill). For coarse fill, use 1.5 gallons per 10 square feet or as specified on the product label. 2) Unless otherwise directed by the label, soil backfill areas next to walls, piers, pipes and under "critical areas" like slab expansion joints are treated with 4 gallons per 10 linear feet per fbot of depth. (This includes fill areas inside chimneys and earth - filled porches). 3) Hollow masonry units receive 2 gallons per 10 linear feet. Though a concrete block wall may have multiple chambers (2 or 3 hole blocks), it is counted as one hollow void when calculating the amount of termiticide needed for treatment. Review specific label requirements for proper mixture rates and application procedures. 3) Wood applied termiticide treatments are to be applied according to the label directions. Page 1 of 2 6-d 09SB-928-9E6 `siapjing wogsn0 ezeJpod SS=8 8002 02 2nd . 4 BUILT' ING -HERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http:,/,`/bpinspect.cstx.gov --------------------------------------------------------------------------- Application Number . . . . . 07-00002902 Date 10/15/07 Application pin number . . . 073170 Property Address . . . . . . 4413 AMBERLEY PL Property ID: 184200-0601-0040 R #: R303783 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE PH 6 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 275000 Owner Contractor ------------------------ ------------------------ PODRAZA CUSTOM BUILDERS INC PODRAZA CUSTOM BUILDERS, INC PO BOX 592 P.O. BOX 592 NAVASOTA TX 778680592 NAVASOTA TX 77868 (979) 690-3810 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE WOOD STUD IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2750.00 INTERIOR WALL TYPE WOOD STUD NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TRAFFIC IMPACT ANAL (TAZ) 441.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 530196 Permit Fee . . . . 985.00 Plan Check Fee .00 Issue Date . . . . 10/15/07 Valuation . . . . 275000 Expiration Date . . 4/12/08 Qty Unit Charge Per Extension BASE FEE 460.00 175.00 3.0000 THOU BLDG, VAL 100001-500000 525.00 ---------------------------------------------------------------------------- Special Notes and Comments -Attic Space to Be Used for Storage Only, No plans submitted to indicate anything else.. - --------------------------------------------------- ----- -'---------- BUILDING DE ATIVE : l/�J APPLICANT: BUIVDING. ►PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002902 Application pin number . . . 073170 Page 2 Date 10/15/07 Special Notes and Comments -Narrow Wall Bracing Fully Sheathed with APA 20" Minimum Breakfast Area Framing with 2X12 minimum Header. Will remove side breakfast area window per Ronnie and remove French doors and replace with a single door to get 28" minimum OSB. ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2006 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED --------------------------------------------- ------ --- - ------ ---------- BUILDING DEPT R SENTATIVE: APPLICANT: BUILDING ePERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00002902 Date 10/15/07 Application pin number . . 073170 ---------------------------------------------------------------------------- Special Notes and Comments Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 THE MAXIMUM ALLOWABLE ZRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating ------------------------------ BUILDING DEPT ENTATIVE: ` APPLICANT: / BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number 07-00002902 Date 10/15/07 Application pin number 073170 ---------------------------------------------------------------------------- Special Notes and Comments of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 200 TO 30% A .35 FACTO OR LOWER SHALL BE MET. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC ) RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mec anical) WORK MUST --------------------------------------- - - ------------------ BUILDING DEPTV,TNTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 07-00002902 Date 10/15/07 Application pin number . . . ------------------------------------------------------------------7--------- 073170 Special Notes and Comments BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited ------------------------------ Due Permit Fee Total 985.00 985.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1735.00 1735.00 .00 .00 -------------------------------------------- ------------ BUILDING DEPT R E ENTATIVE: J) 0 4 APPLICANT: TEMPORA9Y POLE PERMIT CITY OF COLLEGE.STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00002903 Date 10/15/07 Application pin number — . 149005 Property Address . . . . . . 4413 AMBERLEY PL Property ID: 184200-0601-0040 R #: R303783 Application type description TEMP POLE Subdivision Name . . . . . . CASTLEGATE PH 6 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . UNKNOWN Application valuation . . . . . 0 Owner Contractor ------------------------ PODRAZA CUSTOM BUILDERS INC ------------------------ PODRAZA CUSTOM BUILDERS, INC PO BOX 592 P.O. BOX 592 NAVASOTA TX 778680592 NAVASOTA TX 77868 (979) 690-3810 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . AC Permit pin number . 530204 Permit Fee . . . . 20.00 Issue Date . . . . 10/15/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------------------------- - - - --- - - - - - - - - ;�� - - - - - - - - - - - BUILDING DEPT SENTATIVE: APPLICANT: Fir Plans Examiner ZA44 c- Fmc 5-6A► or"J4 , pw FiavI• ov+. J1ACAJ7, A «C% — /Irta��t/� 21'e1G qFor O Use Only APPLICATION FOR BUILDING PERMIT DATE: `'�TRCC REG —` CCITY ITY TEXAS COS LEGSAVENSTATION APPLICATION # COLLEGE STATION, TX 77840 TEMP POLE # CITY OF COLLEGE S` NI -ION (979) 764-3570 (979) 764-3496 FAX Planning cs. Devekprne-at $qi ivn WWW.CSTX.GOV ADDRESS/LOCATION: 4913 PrM&ERLEY flace LOT _V BLOCK SUBDIVISION CAME G ATC SEC/PH !! w BUSINESS/OWNER NAME: PODRAZA CJSTCM 1ALDS1115 PHONE: 511- logo - 3%10 1 Rice) CONTRACTOR/HOMEOWNER: /1 PHONE: CONTACT PERSON FOR REVIEW COMMENTS: RoNNI fr PHONE: 17 1- Z 1$^ 0- D7 df -mc) FAX: t- 966 - HL11--1125 ELECTRICIAN: N14Ti14EW5 Et-19-MC_ HVAC: An, eDn1G--'OT ACCESSORY/STORAGE ADDITION DEMOLITION (ASBESTOS SURVEY) DUPLEX:(LANDSCAPE PLANS REQUIRED) LOCATION DESCRIPTION OF WORK: KIESIDEti PROPOSED USE: (yCW STRUCTURE USE: I'to\jSt EMAIL: pcdre-7.Ab01Mej Cd gnnctil. om PLUMBER: CR NAT614_4 fR_Un.blNq GOOD CENTS (Residential only): No ■ • ■ W • NO Ed Mti HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITT TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPR VALUATION: $ 7.75,00D ✓/ TOTAL AREA: (Cost of Labor and Materials) 317Z6 PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM SEWER TAP O0 • D WATER TAP: � (0 OTHER TAP: TEMP POLE GARAGE TYPE: y„ S12E g,� u S12E SIZE SINGLE a ATTACHED 21 lig APPROVAL: yeS J HEATEDAREA: *ZjSO 4 NUMBER OF BATHROOMS: INTERIOR WALL TYPE: V OJD - 5-Tu Q EXTERIOR WALL TYPE: WOop - 51 VD FOUNDATION TYPE: 5L,4,t3 ROOF TYPE: 5i+%o( .E DOUBLE F-'] TRIPLE a DETACHED F__j CARPORT SIGNATURE OF APPLICANT: *If proposed work involves new commercial construction or facade improvements/renovations to an existing commercial property, building elevations are required. ............................................................ Official Use Only 07 Comments: ✓ /' 7 / <53, or NO ZT-ay fficial /hiss w/ jAj4 &"a4f 4- P& .ev4 04 Aol,z w,klak l 11C- rol. (y Ajo' - Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls] Insulation R value of ceiling 1 (flat areas) 130 Insulation R-value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) 5 Glazing U-Factor t S R value of ductwork (j A/C SEER Rating 13 Protection Against Subterranean Termites Chemical Termiticide Treatment (Soil Treatment) Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. CITY OF COLLEGE STATION planning 6- Development Snvieei PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 0% O cl DATE: _ % BUILDING ADDRESS: I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 6mil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated O 11. Framing: Floor, Wall, Ceiling and Roof Requirements A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck R&QK E. Header sizes indicated on plans NA/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing plan or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX Q. Tempered Glass required in all hazardous locations L R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK 100K A. Stairway Details NAM 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements Wfft A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NAT 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N 4K B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 860 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 IN!Akoo Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed OJOK "APPROVED PLANS PER IRC SECTION R106.3.1." I CITY OF COLLEGE STATION Planning d Dtvtlopment Sttvita PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS J4 -� PLANS EXAMINER CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX DATE I` LEWLIC 05, — >a' buiidinq line O r �LF- ar z Foundation outline ' i!1 Speculative Residence r ?AN EL I I ' I cons. apron 25' uilding line "VoIlly oNly Zot 4' walk i - - - - - - - I - -- � 12' drive 05, LOT: 4 PODRAZA BLOCK: I CASTLEGrtATE CUSTOM SECTION: to BUILDERS. 0 5' 10' 20' 40' 60' SCALE: 1 "=20' 51 TE FLAN p Manber chid - RESchi?ck-Compliance Cefttate Clwked By/Date 200.0 IWC RE&71jeck'Soffware Version 3-.6RAease 2-' Data filename: UXProgram Fi.tesNCheck�RESeheck\PODRAZA—CASTLEGATE—LOT 4.rck 'Speculative Re's"tae'n' be"'; CITY: College Station STATE: Texas HDD: 1788 CONSTRUCfl&TVTE' Single. Family W WDOWW:h WALE R-XT'­10:.0.J4: DATE: 07J20/07 DATE -OF. P.LANS,.--,07.20'01 PkOJE_CT_DES CIUPt-16N' Lut 4 Block I Section-6 CastlegaLe Subdivision DESIGNER/CONTRACTOR: Podraza Custom Builders COMPLIANCE: -Passes Maximum UA = 1172 Your Home UA = 855 27.0% Better Than Code (UA) Maximum SHGC = 0.40 Your SrfGC = 0.35 Clg. 1: flat clg.: Flat Ceiling or Scissor Truss Wall I : 2 x. 4 walls: Wood* Frame, 16" o. c. Window I SH: Vihyf Fktme:Doubfe Pane with Low-E' .Sfi(-i(—: 0.34 Window. 2 FXD.: Vinyl Frame:Double Pane with Low-E SHGC: 0.33 Door 1: Solid Door 2: Glass SHGC: 0.40 Rioor i - -Slab-On-CrMe-.Unheated Gross Glazing Area or Cavity . Cont. or Door - Perimeter R-Value R-Value U-FactoT UA 2694 30.0 0.0 94 2982 0.0 0.0 208 257 0.650 ' 167 .66 .0.520 34 24 0.400 10 100 0.400 40 290 0.0 302 Lisulation depth: 0.0' Furnace 1: Forced Hot Air, 80 AFUE Air Conditioner 1: Electric Central Air, 14 SEER COMPLIANCE STATEMENT: The propus&d building -design descn-bed here is consisttait With the building plans, spaifi ttions, and other calculations submitted with the permit -application. The proposed building has been -designed to meet the 2000 iFCC requirements in RF,Scheek Version 16 Release 2 (brmerly WCcheck) and to comply with the mandatory rcquiremcuts listed in the RES ieckIuspcction Checklist. __�O7 Builder/Designer Date G