Loading...
HomeMy WebLinkAboutADDN2007-02878PREPARED 2/12/08, 12:00:46 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/12/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 1303 MISSION HILLS DR SUBDIV: PEBBLE CREEK TENANT, NBR: OUTDOOR KITCHEN CONTRACTOR MARIOTT HOMES PHONE (979) 696-1787 OWNER CLOSE, KENNETH R & CHRISTINA R PHONE PARCEL 497900-0060-0030 APPL NUMBER: 07-00002878 RESIDENTIAL, ADDITION ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 10/09/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 10/09/07 AP October 8, 2007 11:53:00 AM kwolfe. tuesday morning B125 0 2/12/08 BI BLDG, FINAL TIME: 17:00 February 12, 2008 9:46:13 AM acarter. COMMENTS AND NOTES Date: 2/12/2008 [nspection Comments for Final, Permit Year: 7 'ermit Number: 287E Address: 1303 MISSION HILLS DR Type Type Code Status Inspection Result Comments Description Description E110 ELEC, ROUGH IN IC 09/28/2007 02:46 PM RH PDA Ell ELEC, ROUGH IN IC Electrical in slab rough -in. E150 ELEC, FINAL IC February 4, 2008 4:29:13 PM kwolfe. Bb1G PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . '. . . . 07-00002878 Date 9/24/07 Application pin number . . . 147052 Property Address . . . . . . 1303 MISSION HILLS DR Property ID: 497900-0060-0030 R #: R301294 Tenant nbr, name . . . OUTDOOR KITCHEN Application type description RESIDENTIAL, ADDITION Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 44872 Owner Contractor ------------------------ ------------------------ CLOSE, KENNETH R & CHRISTINA R MARIOTT HOMES 1303 MISSION HILLS DR 209 ROCK PRAIRIE RD COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 696-1787 --------------------- Structure Information 000 000 ---------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE SHEETROCK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) N/A HEATED AREA 1.00 INTERIOR WALL TYPE N/A SEWER TYPE PUBLIC ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 526681 Permit Fee . . . . 235.00 Plan Check Fee .00 Issue Date . . . . 9/24/07 Valuation . . . . 44872 Expiration Date . . 3/22/08 Qty Unit Charge Per Extension BASE FEE 15.00 44.00 5.0000 THOU BLDG, VAL 1001-50000 220.00 ---------------------------------------------------------------------------- Special Notes and Comments -Adding covered porch kitchen area. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S --------------------------- -----X.- - ----------------- BUILDING DEPT_.. i ESENTATIVE : APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 07-00002878* Date 9/24/07 Application pin number . . . 147052 ---------------------------------------------------------------------------- Special Notes and Comments ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total Plan Check Total Grand Total 235.00 235.00 .00. .00 .00 .00 .00 .00 235.00 235.00 .00 .00 ------------------------------ =------------- BUILDING DEPT R RESEN ATIVE: o. APPLICANT: _ APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLFG.E.STATIQN. (979) 764-3570 (979) 764-3496 FAX Planning6Oryelopmen'FSe'rviu ' WWW.CSTX.GOV DATE- " TRCC R APPLICATION #� TEMP POLE # ADDRESS/LOCATION: �� O3 /f /1 ASS/�� �GIS u/1 ✓ LOT � BLOCK SUBDIVISION b2lgG C�QE L %� SEC/PH-Sa BUSINESS/OWNER NAME: eKit.G-9i19�C�7ti Gf»S�� PHONE: l/f �� 2, CONTRACTOR/HOMEOWNER: to k0l*1411 PHONE: O 1Y` �U / CONTACT PERSON FOR L REVIEW COMMENTS: [ ?'a" PHONE: d �� FAX: � cPa_ `�f�� EMAIL: ELECTRICIAN: AR, Ld c G7"/1 e G PLUMBER:A/ HVAC: GOOD CENTS (Residential only): ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEURENOVATION" SWIMMING POOL TENT/CANOPY DESCRIPTION OF I PROPOSED USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ Y� TOTAL AREA:S�i G HEATED AREA: �— (Cost 6f La or and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: ❑ SEPTIC/TREATMENT SYSTEM ❑ SEWER TAP: ❑ WATER TAP: ❑ OTHER TAP: TEMP POLE GARAGE TYPE: SIZE SIZE SIZE SINGLE NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE F—] TRIPLE ATTACHED,,�� DETACHED a a SIGNATURE OF APPLICANT: "If proposed work involves new commercial constru Ion or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only 6 Plans Examiner Zoning Official Camments: YES r NO Fire Marshall It Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating Protection Against Subterranean Termites 4A ❑ Chemical Termiticide Treatment (Soil Treatment) CIA ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. N CITY OF COLLEGE STATION Planning & Dnxlopmrnt Snvira PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 017 _ DATE: L?-Zy BUILDING ADDRESS: 303 P0 '% sioa/ ;11 fir?. I. Foundation Requirements- Minimum City Foundation Standards N K A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex CAMIK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans NA/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roofcovering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans .t CITY OF COLLEGE STATION Planning 6 Drmlopment Servira PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX Q. Tempered Glass required in all hazardous locations UL R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements "OK OK A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements NA/ A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: OK 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required CITY OF COLLEGE STATION Planning 6 Dt Iopmtnt Strvita PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NA/ B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements OK A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 860 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow FK Elevation certificate needed —@— "APPROVED `'a CITY OF COLLEGE STATION Planning d Development Snvita PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX ! ! _ _ PROPERTY LINE: 150.00' - N 23-5012011 N I o / _ _ _ _ 7.5' UILDING SETBACK LINE 3Lo to Lu N PROPOSED EXIS ING Q I Lu I N I n/ W ADDITION RESI NCE I I i 1 Q/ O/ zl - �/ uj wl 1ij p l l m I 51 co of (LI / NI of w W I i i I al /- - - - 7.5 BUILDING SETBACK LINE - - - - I PROPERTY LINE: 153.80' - N 27-2313711 N I SITE FLAN 0 LOT:-pe O 3 BLOCK: -�5 490 SUBDIVISION: I PEBBLE GREEK PHASE 7-132 COLLEGE STATION, TX BRAZOS COUNTY iAL I= Ol.