HomeMy WebLinkAboutADDN2007-02878PREPARED 2/12/08, 12:00:46 INSPECTION TICKET PAGE 6
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/12/08
------------------------------------------------------------------------------------------------
ADDRESS . : 1303 MISSION HILLS DR SUBDIV: PEBBLE CREEK
TENANT, NBR: OUTDOOR KITCHEN
CONTRACTOR MARIOTT HOMES PHONE (979) 696-1787
OWNER CLOSE, KENNETH R & CHRISTINA R PHONE
PARCEL 497900-0060-0030
APPL NUMBER: 07-00002878 RESIDENTIAL, ADDITION
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 10/09/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00
10/09/07 AP October 8, 2007 11:53:00 AM kwolfe.
tuesday morning
B125 0 2/12/08 BI BLDG, FINAL TIME: 17:00
February 12, 2008 9:46:13 AM acarter.
COMMENTS AND NOTES
Date: 2/12/2008
[nspection Comments for Final,
Permit Year: 7 'ermit Number: 287E
Address: 1303 MISSION HILLS DR
Type
Type Code
Status
Inspection Result Comments
Description
Description
E110
ELEC, ROUGH IN
IC
09/28/2007 02:46 PM RH PDA
Ell
ELEC, ROUGH IN
IC
Electrical in slab rough -in.
E150
ELEC, FINAL
IC
February 4, 2008 4:29:13 PM kwolfe.
Bb1G PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . '. . . . 07-00002878
Date 9/24/07
Application pin number . . . 147052
Property Address . . . . . . 1303 MISSION HILLS DR
Property ID: 497900-0060-0030
R #: R301294
Tenant nbr, name . . . OUTDOOR KITCHEN
Application type description RESIDENTIAL, ADDITION
Subdivision Name . . . . . . PEBBLE CREEK
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 44872
Owner Contractor
------------------------ ------------------------
CLOSE, KENNETH R & CHRISTINA R MARIOTT HOMES
1303 MISSION HILLS DR 209 ROCK PRAIRIE
RD
COLLEGE STATION TX 77845 COLLEGE STATION
TX 77845
(979) 696-1787
--------------------- Structure Information 000 000 ----------------------
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE
SHEETROCK
IMPACT/PRORATA FEES PAID
N/A
FOUNDATION TYPE
SLAB
TYPE OF GARAGE (ATT/DET)
N/A
HEATED AREA
1.00
INTERIOR WALL TYPE
N/A
SEWER TYPE
PUBLIC
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . AC
Permit pin number . 526681
Permit Fee . . . . 235.00 Plan Check Fee
.00
Issue Date . . . . 9/24/07 Valuation . .
. . 44872
Expiration Date . . 3/22/08
Qty Unit Charge Per
Extension
BASE FEE
15.00
44.00 5.0000 THOU BLDG, VAL 1001-50000
220.00
----------------------------------------------------------------------------
Special Notes and Comments
-Adding covered porch kitchen area.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
--------------------------- -----X.-
- -----------------
BUILDING DEPT_.. i ESENTATIVE :
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 07-00002878* Date 9/24/07
Application pin number . . . 147052
----------------------------------------------------------------------------
Special Notes and Comments
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total
Plan Check Total
Grand Total
235.00 235.00 .00. .00
.00 .00 .00 .00
235.00 235.00 .00 .00
------------------------------ =-------------
BUILDING DEPT R RESEN ATIVE:
o.
APPLICANT:
_ APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLFG.E.STATIQN. (979) 764-3570 (979) 764-3496 FAX
Planning6Oryelopmen'FSe'rviu '
WWW.CSTX.GOV
DATE- " TRCC R
APPLICATION #�
TEMP POLE #
ADDRESS/LOCATION: �� O3 /f /1 ASS/�� �GIS u/1 ✓
LOT � BLOCK SUBDIVISION b2lgG C�QE L %� SEC/PH-Sa
BUSINESS/OWNER NAME: eKit.G-9i19�C�7ti Gf»S�� PHONE: l/f �� 2,
CONTRACTOR/HOMEOWNER: to k0l*1411 PHONE: O 1Y` �U /
CONTACT PERSON FOR L
REVIEW COMMENTS: [ ?'a" PHONE: d ��
FAX: � cPa_ `�f�� EMAIL:
ELECTRICIAN: AR, Ld c G7"/1 e G PLUMBER:A/
HVAC: GOOD CENTS (Residential only):
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEURENOVATION" SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF I
PROPOSED USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ Y� TOTAL AREA:S�i G HEATED AREA: �—
(Cost 6f La or and Materials)
PUBLIC SEWER NUMBER OF BEDROOMS:
❑ SEPTIC/TREATMENT SYSTEM
❑ SEWER TAP:
❑ WATER TAP:
❑ OTHER TAP:
TEMP POLE
GARAGE TYPE:
SIZE
SIZE
SIZE
SINGLE
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE F—] TRIPLE
ATTACHED,,�� DETACHED
a
a
SIGNATURE OF APPLICANT:
"If proposed work involves new commercial constru Ion or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
6
Plans Examiner
Zoning Official
Camments:
YES r NO
Fire Marshall
It
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
4A
❑ Chemical Termiticide Treatment (Soil Treatment)
CIA
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
N
CITY OF COLLEGE STATION
Planning & Dnxlopmrnt Snvira
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 017 _
DATE: L?-Zy
BUILDING ADDRESS:
303 P0 '% sioa/ ;11 fir?.
I. Foundation Requirements- Minimum City Foundation Standards
N K
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
CAMIK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roofcovering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
.t
CITY OF COLLEGE STATION
Planning 6 Drmlopment Servira
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
Q. Tempered Glass required in all hazardous locations
UL
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
"OK
OK
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
OK
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
CITY OF COLLEGE STATION
Planning 6 Dt Iopmtnt Strvita
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NA/
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
OK
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 860
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
FK
Elevation certificate needed
—@—
"APPROVED
`'a
CITY OF COLLEGE STATION
Planning d Development Snvita
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
!
! _ _ PROPERTY LINE: 150.00' - N 23-5012011 N I
o / _ _ _ _ 7.5' UILDING SETBACK LINE
3Lo
to
Lu N
PROPOSED EXIS ING Q I Lu I N I
n/ W ADDITION RESI NCE I I i 1
Q/ O/ zl -
�/ uj wl
1ij p l l m I 51
co
of (LI
/ NI of w
W
I
i i I al
/- - - - 7.5 BUILDING SETBACK LINE - - - - I
PROPERTY LINE: 153.80' - N 27-2313711 N
I SITE FLAN 0
LOT:-pe O 3
BLOCK: -�5 490
SUBDIVISION: I
PEBBLE GREEK
PHASE 7-132
COLLEGE STATION, TX
BRAZOS COUNTY
iAL
I=
Ol.