HomeMy WebLinkAboutRES2007-02865, 07-2866O LTEMP��
PREPARED
3/24/08, 14:27:24
INSPECTION TICKET PAGE 1
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: ROBERT HUDSON DATE 3/24/08
ADDRESS
. : 4235 ROCKY RHODES
DR SUBDIV: CASTLE ROCK
CONTRACTOR BLACKHAWK CUSTOM
HOMES INC PHONE (979) 574-5459
OWNER .
.
PHONE
PARCEL .
. 184100-0180-0060
APPL.NUMBER: 07-00002865 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
10/17/07 JGM
BLDG, FOUNDATION -SLAB TIME: 17:00
10/17/07 AP
October 17, 2007 10:36:18 AM glsouth.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
11/29/07 RH
BLDG, FRAMING TIME: 17:00
11/29/07 AE
November 29, 2007 10:51:27 AM glsouth.
11/29/2007 03:15 PM RH PDA
Need proper apa at garage. Need to finish fireplace and
fireblocking at fireplace. Tape seal holes in Tyvek. By
insulation.
BJ,?O 01_
12/04/07 RH
BLDG, FRAMING -PARTIAL TIME: 17:00
4
12/04/07 AP
December 4, 2007 2:44:40 PM glsouth.
APA FRAMING PARTIAL
B130 01
12/06/07. RH
BLDG, INSULATION TIME: 17:00
12/06/07 AP
December 6, 2007 10:22:24 AM kwolfe.
B125 01
3/24/08 RAP
BLDG, FINAL TIME: 17:00
March 24, 2008 2:26:11 PM kwolfe.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
s
V L
WF0968497 / 001 City of College Station
PAGE 1
REQ. DATE: 09/24/07 09/24/07 12:41:57
LOCATION: 4235 ROCKY RHODES DR LOC ID: 209694
REQUESTOR: BLACKHAWK CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 09/24/07 SCHED COMPLETION: 09/24/07
JOB ORDER RESULT COMMENTS
Mar 26 08 01:10p MACIAS _ 9797744736 p.2
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
QoQpedy-Ownor: BLACKHAWK CUSTOM HOMES
Location to be Treated: 4236 ROCKY RHODES
Approximate Measures to be Treated: 2217
Percentage of Termticide(s) to be applied at this location: 0.06% 74 GAL
Tyne of Treatment Full Padiial XXver-tical XX
Horizontal/Perimeter Beam_XX
Foundation: SLAB Siding: BRICK �.
Primar- Usk-.--SIDENCE Roof: COMPOSITION
A LABEL FOR ANY OTHER PESTICIDE R£COMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY)
INCLUDING AREA COVERED. TIME PERIOD OF WARRANTY. RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE-
TREAT FOR TERMITE INFESTATIONS OR REPW R DAMAGE CAUSED BY TF_RhME INFESTATIONS WITHIN THE WARRANTY PERIOD. AND THE CONDITIONS THAT
COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED.
Charges for pre treat:
NOTES: Annual re-newal:
SEE ATTACHED SKETCH
BUILDERS SUPPLIES SKETCH/ PLAN
J:u:4-
�• ts"q.j
$335.88
$120.00
32129 PT 10/15/2007
Ca er Techinden SPCB IIcetme # 3Y128 PT
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name
Legal Description
Property Zoning
Owner . . . . . . . . .
Contractor . . . . . .
Application number
Description of Work
Construction type
Occupancy type
Flood Zone . . . . . .
3/26/08
184100-0180-0060
4235 ROCKY RHODES DR
COLLEGE STATION TX 77845
CASTLE ROCK
CASTLEROCK PH lA
BLK 8 LOT 6
PLANNED DEVL DISTRICT
BLACKHAWK CUSTOM HOMES INC
979 574-5459
07-00002865 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
C-
0
Approved . . . . . . .
Of f icia
VOID UNLESS SIGNED BY BUILDING OFFICIAL
1 APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
t* ff 1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY01:C0I.1-L-:GESTNI'1 14 (979) 764-3570 (979) 764-3496 FAX
llkwlin3 d-0—kp—1 t svrd('a
WWW.CSTX.GOV
ADDRESS/LOCATION: H235 1ZoG1ci �Iodr-s Of.,/
LOT BLOCK SUBDIVISION Ca t&IG F_o k- ✓ SEC/PH
BUSINESS/OWNER NAME:I�Ckl,�,wl�('�) (Or', OrnGS I/JG PHONE:
CONTRACTOR/HOMEOWNER:6fg4bri,/kc--.4)5Un. goyn'-5PHONE: Jli Sly--56ojro
CONTACT PERSON FOR REVIEW COMMENTS: �� I 't CWDG PHONE: q7q V _SGo�
FAX: 1 1 " (0"l3�' 2.�% EMAIL: IGGI % 614C ��tW<<c(%`JrDY�1��" •GOr�
ELECTRICIAN: r radCnce. PLUMBER: Car)01�_I1A✓
HVAC: r .If a r C-6 trf.G GOOD CENTS (Residential only):
ACCESSORY/STORAGE MOVING RE -ROOF
ADDITION NEW CONSTRUCTION` SHELL ONLY
DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY
DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL
LOCATION REMODDEURENZlrdk
TIOW TENTS
DESCRIPTION OF WORK: &NskfoG'� on � S� 1"L51'��nc�
PROPOSED USE: 'ra
//� IG m'.1 /�G`�I�lLr1C�%
STRUCTURE USE: 7t WI/_ ��r �!� !eAidet ,,Pi
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: V
TEXAS ACCESSIBILITY STANDARD
I (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ I Sf 0 VTOTAL AREA7-,Z' � HEATED AREA:
(Cost of La or and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
X SEWER TAP: L
WATER TAP:
OTHER TAP:
,N:TEMN POLE
GARAGE TYPE
3 LA
SIZE
SIZE
SINGLE
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS: Z
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE N%9 TRIPLE
DETACHED jn CARPORT
,Ey15f14 _Fsforlc.
5514L on wk..,
El
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial constru on or facade improvements/renovations to an existing
commercial property, building elevations are requ' d. A.211110L E �L<!
Official Use OnlyMi Y is
o� Plans Examiner Zoning Official
f1w 40", e,
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
XChemical Termiticide Treatment (Soil Treatment)
�3
3-110
z-owe, Z70
�54
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
* Verification of Application shall be submitted to the City of College Station
Building Division prior to issuance of the Certificate of Occupancy.
rij
CITY OF COLLEGE STATION
Planning d Developmenr Semirei
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# _ S
DATE:
i Z
BUILDING ADDRESS: //L
I. Foundation Requirements- Minimum City Foundation Stan ards
NAICW
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
A/ K
ll. Framing: Floor, Wall, Ceiling and Roof Requirements
A/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
CITY OF COLLEGE STATION
Planning & Development Semiem
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
Q. Tempered Glass required in all hazardous locations
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
OK
A. Stairway Details
K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
(Ty
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
.t
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NAIdW
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 860
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate neededMPK_
"APPROVED PLANS PER IRC SECTION R106.3.1."
'
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
PLANS EXAMINER
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
DATE
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . 07-00002866 Date 9/24/07
Application pin number . . . 948832
Property Address . . . . . . 4235 ROCKY RHODES DR
Property ID: 184100-0180-0060
R #.
Application type description TEMP POLE
Subdivision Name . . . . . . CASTLE ROCK PH lA
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL DISTRICT
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
BLACKHAWK CUSTOM
HOMES INC
3211 INNSBRUCK CIR
COLLEGE STATION
TX 77845
(979) 574-5459
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. AC
Permit pin number
. 526640
Permit Fee . . .
. 20.00
Issue Date
9/24/07
Valuation . .
. . 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
---------------------------- - - - - ---------------- --- ---- --------------
BUILDING DEPT REPRESENTAT E:
APPLICANT: �-�--
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00002865 Date 9/24/07
Application pin number . . . 858480
Property Address . . . . . . 4235 ROCKY RHODES DR
Property ID: 184100-0180-0060
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . CASTLE ROCK PH lA
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL DISTRICT
Application valuation . . . . 151700
Owner Contractor
------------------------ ------------------------
BLACKHAWK CUSTOM HOMES INC
3211 INNSBRUCK CIR
COLLEGE STATION TX 77845
(979) 574-5459
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER. OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1666.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 441.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . AC
Permit pin number . 526632
Permit Fee . . . . 616.00 Plan Check Fee .00
Issue.Date . . . . 9/24/07 Valuation . . . . 151700
Expiration Date . . 3/22/08
Qty Unit Charge Per Extension
BASE FEE 460.00
52.00 3.0000 THOU BLDG, VAL 100001-500000 156.00
----------------------------------------------------------------------------
Special Notes and Comments
-Narrow Wall Bracing Fully Sheathed with APA Framing at
Garage Area 16" Minimums.
---------------------------
--- ------------ ------ ---.---'------------
BUILDING DEPT REPRESENTAT E:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002865
Application pin number . . . 858480
Page 2
Date 9/24/07
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULAT ON
--------------------------------------------------�-- - ,---------
BUILDING DEPT REPRESENTA VE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number 07-00002865 Date 9/24/07
Application pin number . . . 858480
----------------------------------------------------------------------------
Special Notes and Comments
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC.CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM ORCED AIR
------------------------------------------------ ----- --- - -----
BUILDING DEPT REPRESENTA VE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
-----------------------------------------------------------------------------
Page 4
Application Number 07-00002865 Date 9/24/07
Application pin number . . . 858480
----------------------------------------------------------------------------
Special Notes and Comments
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20%
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid
----------
Credited
--------------------
Due
Permit Fee Total
616.00
616.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1366.00
366.00
.00
.00
------------------------------------
BUILDING DEPT
REPRESENTATI
--------------
----------------------
`
APPLICANT:�---
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number .
Application pin number
Q
0
07-00002865
858480
Page 5
Date 9/24/07