Loading...
HomeMy WebLinkAboutRMDL2007-02852r VARIES 18'-0' VARIES 18'-0" TYPICAL 1OC14 PURLINS TYPICAL m IOC14 BEAMS 6" x 6" x M6" TUBE TYPICAL CARPORT PLAN — EVEN CAR SPACES 1-10C14 BEAM TYPICAL TYPICAL COLUMN 6" x 6' x W TUBE Ili I i i� SECTION '.A' 3a a -41n" sg i H '2 4 C FINISH SURFACE TYPICAL FOOTING o i �3' x 3 x 12 GAUGE TUBE TYPICAL COLUMN 6" x 6' x Ms TUBE ,r-FINISH SURFACE TYPICAL FOOTING SECTION 'B' REFER TO SECTION "E' 0 A b+ � BEAM —COLUMN CONN. L3" x 3' x 14 GAUGE WITH (2)V.-14 SCREWS AT EACH LEG (TYPICAL) E SECTION ® ROOF EDGE 416' R WITH (2)%'o HOLES FOR WO BOLTS /-4'4' THICK PLYWOOD DECK SPAN BETWEEN PURLINS �C �t FY=55,000 PSI F SECTION—'C' BEAM IDC14 BEAM b* IQ WITH (2)Y15"0 HOLES 'OR "-0 BOLTS (.TYPICAL) YPICAL COLUMN D BEAM —COLUMN CONN. 6'x6'xWTUBE FY=55,000 PSI G SECTION —COLUMN ' 1-1OC14 BEAMS 'vT ca 10 GAUGE CUP I I Vi-0 A325 BOLTS I 1 I LIWx1W xWx4W yy WITH 4Se'0 HOLE FOR /32 WO BOLT tOC14 BEAM H TYPICAL CONNECTION TYPICAL --CONNECTION K BEAM —BEAM CONNECTION TIPICAL COLUMN FINISH SURFACE GENERAL NOTES: 1. CONFORMS TO 2003 IBC (INTERNATIONAL BUILDING CODE) �6 REBAR X 1'-0' 2. GAUGE SIZES USED ARE MILL GAUGE SIZES (U.S. STD.) AS SHOWN 3. COLUMNS, k BEAMS ARE G-90 GALVANIZED 4. FASTENERS TO BE PLATED STEEL SCREWS WITH WASHERS FORMED INTEGRALLY WITH HEAD. 5. BOLTS TO BE ASTM AS NOTED. 6. ASSUME SOIL PRESSURE .TO BE 2,000 PSF WITH LATERAL BEARING PRESSURE OF 200 PSF/FT OF DEPTH TF a' 7. PLACE CONCRETE AGAINST UNDISTURBED EARTH. 8. CONCRETE TO BE 3.000 PS IN 28 DAYS. IF 7- l �E OF E' 18"0 9. MINIMUM YIELD OF MATERIAL SPECIFIED SECTIONS. 10. ALL COLD FORMED MATERIAL DESIGNED IN ACCORDANCE.WITH 1996 EDITION OF L TYPICAL FOOTING DESIGN LOAM*-* """"""".. YOOSEFLAVI iI LIVE LOAD: 20 PSF DEAD LOAD: 6 PSF •....... • .................. WIND SPEED: 90 MPH (3 SEC. GUST)€NS�OG`��e "B" l,.`4`g`� e`er= EXPOSURE _ IF = 1.0 =` REV DATE O EL Lo CD a m 3 1.1 �- a c1 3 z N Of N a Q I Q W —J C.'D z N f— M �= M O ev 1 C Z O Q M N f\ m Q N ~ Oz 0 da QW DRAWN BY J.B. DATE 01-30-07 ,we { 07-036 smm S-1 *ss n � 4 W W W H a- a ;W Fcn ��, Lu a (n W N LL Wu u- m: a :v o� w�on,- ,z ri •a1 r- i BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 I PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #• Tenant nbr, name . . . . . . Application type description Subdivision Name . . : . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00002852 Date 9/19/07 184968 1001 KRENEK TAP RD 234920-0001-0010 R114564 CARPORT COMMERCIAL, REMODEL/RENOVATION E & M JONES FARM PLACE UNKNOWN 7500 Owner Contractor ------------------------ ------------------------ WATERWOOD TOWNHOMES L.P. NATIONAL CARPORT INDUSTRIES 4200 WOODLAND PARK CT OUTSIDE CITY LIMITS-BL ARLINGTON TX 760135505 COLLEGE STATION TX 77840 --- Structure Information 000 000 REPLACE CARPORT TO MATCH EXISTING Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . UTILITY AND MISCELLANEOUS Other struct info . . . . . IMPACT/PRORATA FEES PAID N/A HEATED AREA 300.00 INTERIOR WALL TYPE BRICK SEWER TYPE PUBLIC ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 525865 Permit Fee . . . . 50.00 Plan Check Fee .00 Issue Date . . . . 9/19/07 Valuation . . . . 7500 Expiration Date . . 3/17/08 Qty Unit Charge Per Extension BASE FEE 15.00 7.00 5.0000 THOU BLDG, VAL 1001-50000 35.00 ---------------------------------------------------------------------------- Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE ---------------------------- - ----- -- -- ------------- BUILDING DEPT REPRESENTATIVE: .�'� APPLICANT': �_ \/ N �/ / BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number 07-00002852 Date 9/19/07 Application pin number 184968 ------------ 7--------------------------------------- 7----------------------- Special Notes and Comments ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK CALL FOR FINAL INSPECTION AT 979-764-3570, REQUIRED PRIOR TO CERTIFICATE OF COMPLETION IS ISSUED. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- Permit Fee Total 50.00 Plan Check Total .00 Grand Total 50.00 50.00 .00 .00 .00 .00 .00 50.00 .00 .00 --------------------------- - ----- ----------------------- BUILDING DEPT PRESENT VE: APPLICANT : APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning d'Dr loprarnt Srrtrirrr W1NW.CSTX.GOV ADDRESS/LOCATION: ll e ) I K. 1`�wG F— 7019 „a LOT BLOCK SUBDIVISION BUSINESS/OWNER NAME: f ►� r I � DATE: TRCC REG APPLICATION # TEMP POLE # PHONE: SEC/PH CONTRACTOR/HOMEOWNER: ijOI IbWAL IUP0k1 S PJ n PHONE: � O3� D"IZ" � D"1 CONTACT PERSON FOR REVIEW COMMENTS: MIKE V C A&'M PHONE: % 14' J 64 ' 1 42..— FAX: "1c)-3' 6qZ' 1 9(D EMAIL: ELECTRICIAN: HVAC: PLUMBER: GOOD CENTS (Residential only): ACCESSORY/STORAGE MOVING RE -ROOF ADDITION NEW CONSTRUCTION* SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION REMODEURENOVATION* n DESCRIPTION OF WORK: 1z4F y� N e1(r —'—xr N o cy� PROPOSED USE: STRUCTURE USE: e tci glr'ri4 tee, , ,q4eW Carr orf rt.i' IM�t O HOMEOWNER ASSOC IATIMARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ �-�7 O VALUATION: $ 1 GOO `0 TOTAL AREA: 3 00 1& KlEATED AREA: (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: SIZE WATER TAP: OTHER TAP: TEMP POLE GARAGE TYPE SIZE SIZE SINGLE ED ATTACHED 71 NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE ED DETACHED TRIPLE a CARPORT SIGNATURE OF APPLICANT: *If proposed work involves new commercial constructl orlpt ade improvements/renovations to an existing commercial property, building elevations are required. .......................................................... Official Use Only L�G� Comments: Wor NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating Protection Against Subterranean Termites ❑ Chemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy.