Loading...
HomeMy WebLinkAboutADDN2007-02841r 0 07aw 499YI PREPARED 2/11/08, 7:51:39 INSPECTION TICKET PAGE 5 City of ------------------------------------------------------------------------------------------------ College Station INSPECTOR: BUILDING INSPECTOR DATE 2/08/08 ADDRESS . : 705 WELSH AVE SUBDIV: COLLEGE PARK TENANT, NBR: ADD BEDROOM/STUDY CONTRACTOR LAWRENCE GUSEMAN CONSTRUCTION PHONE (979) 574-3040 OWNER HOBSON, ROY E & WANDA PHONE PARCEL 195400-1060-0020 APPL NUMBER: 07-00002841 RESIDENTIAL, ADDITION ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 10/15/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 10/15/07 DA October 15, 2007 9:22:38 AM glsouth. 10/15/2007 03:46 PM JGM PDA need proper laps on beam steel, need to raise beam steel B100 02 10/16/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 10/16/07 AP October 16, 2007 9:39:29 AM acarter. B115 01 11/14/07 DS BLDG, FRAMING TIME: 17:00 s .11/14/07 DP November 14, 2007 8:10:57 AM kwolfe. November 14, 2007 4:28:38 PM kwolfe. anchor bolts within 12" of ends of sole plate (back double ' door) nut & washer on anchor bolt under double window backroom need purlin brace on roof rafter B115 02 11/15/07 DS BLDG, FRAMING TIME: 17:00 11/16/07 AP November 15, 2007 9:43:12 AM acarter. B130 01 11/19/07 OC BLDG, INSULATION TIME: 17:00 11/19/07 AP November 16, 2007 1:04:53 PM acarter. B125 01 2/BLDG, FIAL TIE: 17:00 _ 0 /,98 B ,0 C9 (- FebruaryN8, 2008M1:28:00 PM acarter. -------------------------------------- COMMENTS AND NOTES-------------------------------------- Date: 2/11 /2008 [nspection Comments for Final Permit Year: 7 permit Number: 2841 Address: 705 WELSH AVE Type Inspection Type Code Description snsp. Inspection Result Comments B.100 BLDG, FOUNDATION-SL, IC 10/15/2007 03:46 PM JGM PDA B100 BLDG, FOUNDATION-SU IC need proper laps on beam steel, need to raise beam steel B115 BLDG, FRAMING IC November 14, 2007 4:28:38 PM kwolfe. B115 BLDG, FRAMING IC anchor bolts within 12" of ends of sole plate (back double B115 BLDG, FRAMING IC door) B115 BLDG, FRAMING IC nut & washer on anchor bolt under double window B115 BLDG, FRAMING IC need purlin brace on roof rafter Ell ELEC, ROUGH IN IC November 14, 2007 4:30:37 PM kwolfe. E150 ELEC, FINAL IC January 30, 2008 10:54:30 AM kwolfe. M110 MECH, FINAL IC February 6, 2008 1:06:40 PM kwolfe. P100 PLBG, ROUGH IN IC October 8, 2007 4:16:52 PM kwolfe. P100 PLBG, ROUGH IN I IC Inot holding water test Page 1 INTERIOR BEAM BARS 016O.C. EXTERIOR BEAM brick Iedg S vz F .................. 4 rre or 406 •- 8 AY> or BARS 6 N8 _ .� BARS 3• Vapor Retarder H Vapor Retarder (min. 8 mil Poh) (min. 8 mil pob) 9' E 2� 70 STIRRUPS 4• 14' 03 BARS a 48- O.C. 4 ga. WWM ® 24' O.C. or 6 ga. W WM a Is' O.C. INTERIOR SLAB DROP ............................................................................... ..... .0 #8 35" 6'min. GENERAL NOTES: 1. Exterior beam shall extend a minimum of 6 inches into undisturbed soil or fill which is compacted to 95 % Standard Proctor (ASTM D 698) within ( � 2 % of optimum moisture content. All fill material shall have a Plasilicity, Index (P.I.) between 5 and 18. 2. Interior beams that exceed 60 ft.In length must be a minimum of 30" deep. 3. Maximum beam spacing shall be 15 feet and shall be continuous over the length or width of the foundation. 4. Steel to be set to clear bare earth minimum 3", wood or steel form 1 -112". 5. Minimum concrete specified compression strength shall be 3000 psi @ 28 days. 6. Masonry fireplace footings shall be a minimum of 30".deep with 2 mats of #5's @ 12" O.C. both ways. 7. These minimum standards shall apply to all foundations. Exceptions: A. Foundations for temporary buildings and permanent buildings not exceeding one story In height and 400' square feet in area. B. Foundations designed by an Architect registered in the State of Texas or a civil/structural Engineer registered in the State of Texas and approved for use by the Building Official. 8. All foundations designed by an Architect or Engineer shall be Installed as designed. Revisions and exceptions must be submitted in writing by the Architect or Engineer and approved by the Building Official. 9. Reinforcing steel shall be grade 60 (grade 40 allowed for stirrups only). All deformations shall meet ASTM A615. Page 46 of 69 BM Siff MIN lM. INCHES MNIMUM MDIUS OF KENOS #3 12" 15/16" #4 12" 1-1/4" #5 15" 1-9/16" #6 20" 2-1/4" #7 26" 2-5/8" 3" 0..vt.bn DwabOo" 0� BUILDING DIVISION CITY OF COLLEGE STATION MINIMUM FOUNDATION STANDARDS SIZE V0.E7ARE0 12/04 SHEET 1 OF 1 Rev. 03/05 ."A ADDiT0t'l PLAl'j SchLE = 1/4" _ I to.. }FATED Wl� = (0O SF 1/V RAP �U1SE W (?N—P/�Oi STU �2E-gAR�i k� WAu, 1NSLIL tiok = R��tun� = Rt3 . CEI L-ior- (F�SU� —Cj .j = IZVRunc = R3o' °/c OF WPrtUL ©PERT ► A-C = ,18 or It'k 17L2 s'Wets � raA i lP I �ti F or?f-� rtt ; 'JUIaIb MAX. SPAN FLOOR JOISTS MAX. SPAN RAFTER MAX:S�PA:NUNTO HEADER SCHEDULE Am BTm4m 2 X 8 0 18' OC. 13'-2- 40 Pa► UVE IAAO 2 X 12 O 12' QC. 4�m OVQ 3B[AY 21'-7' YAK 9PAN 2 X' 8 O 18' O.G 17•-3' 2X10 O 10' O.C. 20'-G- 2 X 12 O 16' O.C. 2 X 8 0 12- O.2-2 X 4 ON EDGE IN-10' 2 X a O 18' O.2-2 X 8 ON EDGE4'_8• J'-8- 00 N0T F71CCkm aIVE11 DILL 2 X 12 O 24' O.C. 13'-4' 2 X B O 24' 0.2-2 X 8 ON EDGE8'-0' DO NDT EICEED MVW DIILZ4 Psr MYC la-7Ps2-2 X 10 ON EDGE 7'-8' GENERAL FRAMING NOTES WINDER STAIRS w e• ON IREADSOW I'='p�� �mfi2Xaa2C a PI.AIL IMIM otHIP aC. 62x42NDa31fALLBDOIlQmOM>OFS OF ALL � 2 Rooea • NY tUPTIDRB m RAP 018 t o s • ALL COfamt6 AND llptm 7REA0 WD1N 1r FROM e>< : X 14 NARROW EDGE MOT r S PROVIDE 2-2 X 4 STRONO BACK • MWAN OF a PROVIZ SOICLE SCLL PIATE AND COOSE EDP pLA7L 3PAIq OVQI 17-0• I M 2 X 4 COiAII um • 7. PROVIDE t X 4 OIAODNAI LET-N SDm BRACING • ♦'-O' O.C. Ca10®IS O► EX1t •ALLi m t/r BRACINPLrmD 4. PROVIDE 2 X a SCLaSCR jMM a CAT1mRAL amam aMATMAL UM t01La (YA") A) T IN[ 10 W OF INSTµj�jTCOL I . 2 X 10 1KEAOS CLEAR p'..r SpNq LES3 � a1 � a at a'-r an to'-D' an FRONT OF TR TO BE FLUSH Lam IESS � W/ RISER NO AMU t/r 512E8 7t/Y x S/1a' J( 3 t� x a/fa' 7 t/T x a/1a• �/xr i 1' It x aAr x yr j � x y/b• 2 x 12 rcRyP VVAM O MT.w&L t/r - r-w 1. CUT PURUN BRACE BIRD MOUTH 'FIT TO PURUN ANGLE 2. PURUN TO BE O RIGHT ANGLE TO RAFTER 3. DO NOT PRE -BUILD 'T' BRACE, INSTALL 2 X 4 BRACE FIRST, THEN JAMB 2 X 4 AGAINST RAFTER & NAIL TO KNEE BRACE MIN 2-18d RAFTER HANDRA113 (30-Se" Y LEADING EDGE OP TREAD z X 4-a7 VFROCALLY TO NMMWL 2 X 6-#3 PURUN �2-1Bd n 189 O 2 X 4 KNEE BRACE TO RAISED BEAM 24 O.G. GUARDRAIL INTERMEDIATE RAIL • SPACNO SNALL PR(:1pJT PAS OP A M mumv 2 X 4 g3 i7YPK'a1L a�,E S'ICRY SMcnM seAtc I/2' - r-o' 7/Ir am O<<JIDIp No PELT PAPIDI 2 X 4 MAU Tap PLAIT 2X4-0 1 10= 1 x a MARDI ---- rm um INCK 3CLU1031 OOAM--� 3/4' FOL BA= MICATlEIW- FACE iaOl 2X4On=atrCr- TREATID =4 BOT. PLA1 a[LP MCLn • 3r OA )! DE00N PELT PAPER ICP PLA1E P aaoma -LATE I/r S Erm= 4 2 X 12 Am .IOBTB 2 X 4 DCU" IOP RATE 2 4 *TYPE It QARATI01 EMUS -0) 1/r Oa w= BAIT Ka"TION -2 X 4 SNOB • tr as a F w A %� 5l71F P,! SALE 3/3� I'o" Ins W66 S H �kvf--t,44E to-r 3. f Ve- mw 30' of Lor 2, f�K 'F; Co[.t.C6E PjgkK, Couc'sdC S7Afi'a,� � T�XiFS CIS- SURVEYOR'S CERTIFICATE: I, BRAD KERR. R.P.L.S. NO. 4502. DO HEREBY CERTIFY THAT TO THE BEST OF MY KNOWLEDGE THIS PLAT IS A TRUE REPRESENTATION OF A SURVEY MADE ON THE GROUND UNDER MY SUPERVISION AND �- THAT THERE ARE NO VISIBLE ENCROACHMENTS ON THIS TRACT EXCEPT AS SHOWN HEREON. THIS TRAT DOES5/8 INCH IRON THE F RCM. MAPS,NOT 000MMUNITY PANEL NO LIE WITHIN ADESIGNATED 4 0441CO144 C, 100 YEARFLOOD EFFECTIVE DATE:PLAIN AC07-012G 19 1.17 2 ROD FOUND - CM S SCALE: 1 " = 30' ; / / / szS,'��Fo BRAD KERR REGISTERED PROFESSIONAL LAND SURVEYOR NO. 4502 LOT 4 // �, J IN BLOCK F . i ,0' � �\�/��' � 10.Op0 \ S� � 1 /2 INCH IRON �/ y\O��C. gyp. , '11,n �ROD FOUND - CM PSG �p`�? �Q�c. /� \ c+'Ana,-,a.��.a=.:o•:>:...,.,�aUo�.Wfii c;��• �`' /i �e��. LOT 3 o� // BLOCK 'F' •V \� ' :'':,, _,:, ;;.: 1 /2 INCH IRON ° / �.`' �, �� 3y ��• G+ ROD FOUND - CM/ /moo `'�"/'?a f •�O`�' 4 OG LEGEND: o4. 1.36' \ '9L y0 �0� gam/ ©� GS�O1y j / �J 0LIGHT POLE \ O°' \ C/F�,y 9�0• AERIAL ELECTRIC � LINES 4� GAS ti� \ 01 METER \ i �`' �• �g _ WOOD FENCE o—ej--��---�t / i G �L WATER i . CHAIN LINK FENCE —0-0-0-� `�???. METER ?s' CLEAN / / P� OUT x2 / yJQ�i 'A DECK �O, v ��\ st gF9s • CONCRETE A, F .' • �ll �� ..' ::.. i S \ % �.` Q� O LOT 1 CCti . � ��• .�2 BLOCK 'F' � 1/2 INCH IRON �j� ROD ;..•:. ,f FOUND - CM BUILDING SETBACK LINES PER CITY OF COLLEGE STATION U.D.O. (CS) AND DEED RESTRICTIONS, 111/197 (DR). CM - CONTROUJNG MONUMENT FOUND AND USED TO ESTABUSH PROPERTY UNES. ` BEARING SYSTEM SHOWN HEREON IS BASED ON GRID NORTH AS ESTA13USHED FROM GPS OBSERVATION. BUYER LAWRENCE F. GUSEMAN, III TITLE BRAZOS COUNTY COMPANY ABSTRACT COMPANY G.F. No. 145866 LAND TITLE SURVEY PLAT OF LOT 3 & THE NW 30' OF LOT 2, BLOCK 'F' COLLEGE PARK VOLUME 107, PAGE 151 COLLEGE STATION, BRAZOS COUNTY, TEXAS SCALE: 1 INCH = 30 FEET SURVEY DATE: 08-22-07 C PLAT DATE: 08-24-07 JOB NUMBER: 07-659 CAD NAME: 07-659 CR5 FILE: COLPARK (cont); 07-659 (job) PREPARED BY: KERR SURVEYING, LLC 505 CHURCH AVENUE, P.O. BOX 269 COLLEGE STATION, TEXAS 77841 PHONE (979) 268-3195 BUDLD.Ik1Q PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #• Tenant nbr, name . . . . . . Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00002841 612909 705 WELSH AVE 195400-1060-0020 R24146 Date 9/24/07 ADD BEDROOM/STUDY RESIDENTIAL, ADDITION COLLEGE PARK RESIDENTIAL SINGLE FAMILY RESIDENTIAL 30000 Owner Contractor ------------------------ HOBSON, ROY E & WANDA ------------------------ LAWRENCE GUSEMAN CONSTRUCTION 2010 ELMWOOD DR 425 CHIMNEY HILL DR BRYAN TX 778021809 COLLEGE STATION TX 77840 (979) 574-3040 --- Structure Information 000 000 ADDITION Construction'Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info EXTERIOR WALL TYPE SIDING IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE.OF GARAGE (ATT/DET) NA HEATED AREA 600.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 1.00 NUMBER OF BEDROOMS 1.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number 526657 Permit Fee 160.00 Plan Check Fee .00 Issue Date . . . . 9/24/07 Valuation . . . . 30000 Expiration Date 3/22/08 Qty Unit Charge Per Extension BASE FEE 15.00 29.00 5.0000 THOU BLDG, VAL 1001-50000 145.00 ---------------------------------------------------------------------------- Special Notes and Comments 4; ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY ARC -FAULT CIRCUIT INTERRUPTER(S) ------------------------------------- ---- -- -= --- . BUILDING DEPT RFfRESENT�IVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002841 Application pin number . . . 612909 Page 2 Date 9/24/07 Special Notes and Comments PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe U.V. light. ------------------------------------------------�-- - ----------- BUILDING DEPT R)SPRESENT#IVE: APPLICANT: T—L i BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (•979) 764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002841 Application pin number . . . 612909 Page 3 Date 9/24/07 Special Notes and Comments ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 2001 A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTO OR LOWER SHALL BE MET. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND PRIOR TO PLACING FILL. VEGETATION AND FOREIGN WINDOWS ADJACENT TO TUBS FOREIGN MATERIAL FROM SLAB AREA FILL SHALL BE FREE FROM MATERIAL. WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 160.00 160.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 160.00 160.00 .00 .00 ---------------------------------------------------- -- - - --------- BUILDING DEPT REP SENTA VE : � Y APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . 07-00002841 Application pin number . . . 612909 Page 4 Date 9/24/07 BUILDING DEPT EPPRESE ATIVE: s Aoe��- — APPLICANT: . T. APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE.STATiorr Plehni ;De4-0pn ntStrvi. (979) 764-3570 (979) 764-3496 FAX .g:du'. WWW.CSTX.GOV S l.l 1 {, fFor Office Use Only �j� DATE: I `'�RCCREG /`r APPLICATION # ll �� a*A I TEMP POLE # ADDRESS/LOCATION: - / V U-.O > e • LOT 3V �6 LOCK SUBDIVISION Cat," P SEC/PH BUSINESS/OWNER NAME:_—T.' PHONE:giQ-45'144 -3,o4 O CONTRACTOR/HOMEOWNER: `�,gw�f�t,��.Q S'�,,�.Q 4�„ PHONE: Q—tQ -S-1y -3oq Q CONTACT PERSON FOR REVIEW COMMENTS: PHONE: FAX: p EMAIL: �/�v ELECTRICIAN: "'�b PLUMBER:57 �► Cf 45 Z, HVAC: --r D GOOD CENTS (Residential only): CESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: AAIC PROPOSED USE: HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ JV, ood TOTAL AREA: 00 HEATED AREA: 6ekL (Cost of Labor and Materials) dPUBLIC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: WATER TAP: OTHER TAP: TEMP POLE GARAGE TYPE SIZE SIZE SIZE SINGLE ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE FOUNDATION TYPE ROOF TYPE: DOUBLE F-1 TRIPLE DETACHED F__] CARPORT a SIGNATURE OF APPLICANT: v *If proposed work involves new comV cial construction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only ::;��-/fir-o'7 Plans Examiner Zoning Official Co ments: orNO Fire Marshall Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork A/C SEER Rating Protection Against Subterranean Termites Chemical Termiticide Treatment (Soil Treatment) •�f 13 ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy.