HomeMy WebLinkAboutADDN2007-02832wol�a�aa PREPARED 1/07/08, 12:07:01 INSPECTION TICKET PAGE 15 City of College Station 3e INSPECTOR: BUILDING INSPECTOR DATE 1/07/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 3002 LODGEPOLE DR SUBDIV: SOUTHWOOD VALLEY PHS 4B, 7A CONTRACTOR PDALLAS CONSTRUCTION PHONE (979) 690-9205 OWNER OTTE, MELINDA G PHONE PARCEL 582800-0290-0110 APPL NUMBER: 07-00002832 RESIDENTIAL, ADDITION ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 10/15/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 10/15/07 CA October 15, 2007 8:38:43 AM kwolfe. October 15, 2007 1:16:59 PM acarter. B100 02 10/16/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 10/16/07 AP October 16, 2007 9:11:36 AM kwolfe. B115 01 11/09/07 DS BLDG, FRAMING TIME: 17:00 .11/09/07 AP November 9, 2007 8:45:17 AM kwolfe. November 12, 2007 11:46:05 AM kwolfe. B130 01 11/12/07 RH BLDG, INSULATION TIME: 17:00 11/12/07 AP November 12, 2007 11:46:21 AM kwolfe. B1,25.01 1/0 48 B ` BLDG, FINAL TIME: 17:00 J n ry 7, 2008 9:30:40 AM glsouth. ------------------------------ CONTINUED ONTO NEXT PAGE ---------------------------------- D PREPARED 1/07/08, 12:07:01 INSPECTION TICKET PAGE 16 City of ------------------------------------------------------------------------------------------------ College Station INSPECTOR: BUILDING INSPECTOR DATE 1/07/08 ADDRESS . : 3002 LODGEPOLE DR SUBDIV: SOUTHWOOD VALLEY PHS 4B, 7A CONTRACTOR PDALLAS CONSTRUCTION PHONE (979) 690-9205 OWNER OTTE, MELINDA G PHONE PARCEL 582800-0290-0110 APPL NUMBER: 07-00002832 RESIDENTIAL, ADDITION ------------------------------------------------------------------------------------------------ PERMIT: PLBG 00 PLUMBING PERMITS SUB: DOUBLE D PLUMBING (979)693-2284 REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ P105 01 11/07/07 DS PLBG, TOP OUT TIME: 17:00 11/07/07 AP November 7, 2007 11:00:04 AM acarter. for hosebib & vents November 7, 2007 4:49:54 PM kwolfe. P125 01 1/07/08 B PLBG, FINAL TIME: 17:00 �No GAS AND SEWER MUST BE COMPLETED. 7, 2008 10:09:19 AM kwolfe. ------------- ----------COMMENTS jr AND NOTES ----------------------------------- Date: 1 /7/2008 Inspection Comments for Finals Permit Year: 7 Permit Number: 2832 Address: 3002 LODGEPOLE DR Type Inspection Type Code status Inspection Result Comments Description 6100 BLDG, FOUNDATION -SLAB IC October 15, 2007 1:16:59 PM acarter. 6115 BLDG, FRAMING IC November 12, 2007 11:46:05 AM kwolfe. P105 PLBG, TOP OUT IC November 7, 2007 4:49:54 PM kwolfe. Page 1 BUILDING PERMIT r- CITY OF COLLEGE STATION 1101 TEAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . Application valuation . . . . Owner 07-00002832 Date 9/18/07 937056 3002 LODGEPOLE DR 582800-0290-0110 R43710 RESIDENTIAL, ADDITION SOUTHWOOD VALLEY PHS 4B, 7A RESIDENTIAL SINGLE-FAMILY RESIDENTIAL 24000 Contractor OTTE, MELINDA G PDALLAS CONSTRUCTION 6412 S HULEN ST 15985 FM 2154 FORT WORTH TX 761335206 COLLEGE STATION TX 77845 (979) 690-9205 --- Structure Information 000 000 ADDITION Construction Type COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE SIDING IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NA HEATED AREA 325.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BEDROOMS 1.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 525410 Permit Fee . . . . 130.00 Plan Check Fee .00 Issue Date . . . . 9/18/07 Valuation . . . . 24000 Expiration Date . . 3/16/08 Qty Unit Charge 'Per Extension BASE FEE 15.00 23.00 5.0000 THOU BLDG, VAL 1001-50000 115.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade F 11 Minimum of 6" ------------- BUILDING DEPT REPRCs) ------------------------ -- NTATIVE: - ----------- . A n A APPLICANT: BUILDING PERMIT , CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov -----------------------------------------------=---------------------------- Application Number . . . . . 07-00002832 Application pin number . . . 937056 Page 2 Date 9/18/07 Special Notes and Comments inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO IN ECTS AND DECAY -----------------------="--------------------- ---------------- P- BUILDING DET P ESENTATIVE: APPLICANT: BUILDING PERMIT . CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . 07-00002832 Date 9/18/07 Application pin number . . . 937056 ---------------------------------------------------------------------------- Special Notes and Comments SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total Plan Check Total Grand Total 130.00 130.00 .00 .00 .00 .00 .00 .00 130.00 130.00 .00 .00 --- j- --- --`----------- BUILDING DEPT RES�VTATIVE: APPLICANT: (*//q" CITY OF COLLEGE STATION Planning 6 Development Servirer ADDRESS/LOCATION: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOV 5, - b"5 a p. t£ For Office Use Only DATE #1KOO1 TRCC REG APPLICATION # _1 S TEMP POLE # LOT _BLOCK Z SUBDIVISION ss Wooi Vw1 Ie,M SEC/PH_ R/ BUSINESS/OWNER NAME: `�'`�� ' PHONE: Z 2"q ' CONTRACTOR/HOMEOWNER: M'-fI9'P-rr PHONE: S-`tom -7j(oj' CONTACT PERSON FOR REVIEW COMMENTS: IP4"'1*- � PHONE: 7-"Z4 r /Qt7o FAX: oil'?1 69 E 5 Ur ELECTRICIAN. HVAC: &-k - EMAIL: PLUMBER: GOOD CENTS (Residential only): ACCESSORY/STORAGE MOVING RE -ROOF ADDITION NEW CONSTRUCTION* SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION REMODEL/RENOVATION* DESCRIPTION OF WORK: '3Z S- th '01' 7 �e-y , PROPOSED USE: 9" /57a� STRUCTURE USE: A '5 HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ ?-`ti r&-v— TOTAL AREA: I&OrV W HEATED AREA: 4y'*t1' CF_ (Cost of Labor and Materials) 7IZ'S PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 7- SEWER TAP: INTERIOR WALL TYPE: wODy;P SIZE WATER TAP: EXTERIOR WALL TYPE: U 1 S SIZE OTHER TAP: FOUNDATION TYPE: - SIZE TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE ® DOUBLE F TRIPLE F ATTACHED [gj DEYADtiED F__] CARPORT a SIGNATURE OF APPLICANT: *If proposed work involves new commercial construction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only or NO Plans Examiner Zoning Official nn Energy Code Compliance Information % Glazing of exterior walls %VAr Insulation R value of exterior walls C Insulation R value of ceiling 1 (flat areas) P ' 3y Insulation R value of ceiling 2 (vaulted areas/no attic) A Glazing SHGC (Solar Heat Gain Coefficient) Glazing *U-Factor ' R value of ductwork 9' 6 A/C SEER Rating 13, 0 Protection Against Subterranean Termites ❑ Chemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. ---1 L L L LJ L L-L.1 _ + � � _.i -"�,�_ ter- � - - - - os t I ��i;_ 40 _ 7. ff EI 441, or CIS 7 T91: I tm V F�I -�- -- 5 y� � i �Cx S � f �-I-�-�I I I j--� - g-,5 So �L