Loading...
HomeMy WebLinkAboutRES2007-02812, 07-2813f ll i (6/4/2008) Amber Carter - Re: Calling for CO for 1706 Twin Pond Cir Page 1 From: Joe Garcia To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Mitch... Date: 5/15/2008 12:38 PM Subject: Re: Calling for CO for 1706 Twin Pond Cir OK FOR CO. JMG >>> Terry Boriskie 04/24/08 10:49 AM >>> Contacted Donnie Sprague at 218-1918 about the problems. Terry Boriskie City of College Station Residential Plans Examiner Ofc. 979-764-3744 Fax 979-764-3496 >>> Paul Schoenfeld 4/24/2008 9:33 am >>> NO for CO. Water meter lid broken box needs to be raised to grade. Sewer box needs to be raised to grade. Paul >>> Amber Carter 4/21/2008 8:18 AM >>> by 07-2812 Any issues? (0-7p -- a IS t aa, TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT Property Owner• DONOVAN HOMES Lore to be Treated• 1706 TWIN POND CIR. 2461 ( - 1 r. • • 11 i • • • • • 1 • 1 • 1 0.06 - 4•. :.,W • Full: r •, �� •a. 1 • _ • 1 • .1 BRICK Prima A LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY iNFORMATiON (IF ANY) INCLUDING AREA COVERED. TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE- TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED By TERMITE INFESTATIONS WITHIN THE WARRANTY PER10D. AND THE CONDITIONS THAT COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED. Charges for pro -treat: NOTES: Annual re-newal: $344.86 $125.00 32129 PT W28/2007 Ca or Techinckn SPCB Ilemme 0 32129 PT Z•.d £9L90696L6 an6eadS .Q sepe4o a£9:90 80 Zl unf i ACE PEST CONTROL T.P.C.L. # 7120 PT PO BOX 4474 BRYAN, TX 77805 (979)823-7777 (979) 7744736 CERTIFICATE The following property 1706 TWIN POND CJ[JL built by DONOVAN HOMES State of Texas County of BRAZOS the city of COLLEGE STATION Mailing Address SAME Zip code 77845 was treated for subterranean termites on this day SEPTEMBER 28, 2007 and has met with approval. Cost of initial treatment, S344.86, is payable 'upon completion of wont. The treatment is guaranteed for 12 months from the date of treatment. Thereafter, this contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection and renewal fee of S 125 plus tax, for a period of 4 years. ( see attached letter ) If at any time during this contract a reinfestation of subterranean termites should occur, the above said property will be treated at no additional cost to the owner. ACE PEST CONTROL does not accept any liability for any subterranean termite damage repair. Failure to pay the annual renewal fee within thirty days after the inspection date shall be construed as a cancellation of this contract. Any alteration or addition to the foundation of the above described property without proper temute treatrnent by ACE PEST CONTROL Services shall nullify this contract Licensed and regulated by Structural Pest Control Board P.O. BOX 1927 Austin, TX 78767-1927 (512) 305-8250 £'d £9L90696M enbeadg •a selae4o et,9:90 g0 ZL unf SUBTERRANEAN TERN= PRECONSTRUCTION DISCLOSURE FOR EACH ESTIMATE For all treatments there will be a diagram showing exactly what will he treated prior to the beginning of treatment. Review the pesticide label provided to you at this time for minimum treatment standards. Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the law. Review the consumer information sheet for further information. If you have any questions, contact the pest control company or the Texas Structural Pest Control Board, PO Box 1927, Austin, Texas 78767-1927. Telephone number (512) 305-8250. Name of Customer 1 10 6 1/ck Address City State Zip Location to be Treated 1 '�(D Type of Treatment: [ J Full [artiai A label of _ 1 f .�'ck,r �,� termiticide(s) is enclosed. The percentage of the termiticide(s) to be applied at this location is Warranty Information provided must include the Complete Details of any Warranty provided and the following: Time Period of Warranty; Renewal Options and Cost; and Obligations of the Contracting Parties: If the warranty does not include the entire structure treated, the areas included in the warranty are: (specify) _ Total Square Feet to be Treated:--;? LfJ / Total Linear Feet to be Treated:— %Ci ' Approximate Measurements of the Structure(s) to be Treated: .I- 5i$hature of Certified Applicator or Printed Name Date chnician Completing Estimate ej Name of Pest Control Company TPCL. No. Licensed and regulated under the Texas Structural Pest Control Act Texas'Structural Pest Control Board, PO Box 1927, Austin, Texas 78767-1927, Telephone number (512) 3054250. Sample Form —April 4, 2005 Page i of 2 t,'d C9L90696L6 en6eidS •a selaeyo eV9:90 80 Zl unf z4m4 Ace Pest Control Date: October 3, 2007�� P4 Box 4474 979-82s-nor --� �� Bryan TX 77805 TPCL 712fJPT Professional Services At An Affordable Frice At rA< r::S BPI To DONOVAN HOMES 5610 TIMBERLINE COLLEGE STATION, TX. 77845 Service Date Type Of Service All bills DUE on or before the 10"h of the month following date of service. Service Charge of 1 Y. t per month (18 o per year) Added to Past Dues Accounts. THIS PORTION IS FOR YOUR RECORDS. YOUR CHECK IS YOUR RECIEPT 5 Linear Square Check#( Amount 9/28/2007 1706 TWIN PONDS CIR. SLAB PRETREAT 210 2451 �$344 86 — _ -------- —------- it—_--- ••--- Current 1-30 Days 31-40 days 61-90 Days Over 90 Days - Amount Due I : _86 Please return this portion with payment Remittance Date 10/3107 Amount Due 1 $344.86 Amount enclosed ACE PEST CONTROL -TPCLlf7120PT P.O. BOX 4474 BRYAN. TX. 77805 DONOVAN HOMES 11706 TWIN PONDS CIR. SLAB PRETREAT Thank you for your business l•d £9L90696L6 enbeidg •a selaeyC) I e£5:90 80 Z6 unf oop C.5 ' 1, �• 1 i CA 103 R NT 10 Lo 10) 0 � = 20 , Cam =? X _ _I _ 11 � r• i� � r� L ,= �• 00,40- 4f, 7- I_6�5 N`v� 1 T —E(575/2008) Gina Soufhe�land - Re: Calling for CO for 1706 Twin Pond Cir Page 1 From: Paul Schoenfeld To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Joe G... Date: 4/24/2008 9:33 AM Subject: Re: Calling for CO for 1706 Twin Pond Cir NO for CO. Water meter lid broken box needs to be raised to grade. Sewer box needs to be raised to grade. Paul >>> Amber Carter 4/21/2008 8:18 AM >>> by 07-2812 Any issues? -- (5/22/2008)-Gina-Southerland = Re: Calling for' CO for 1706 Twin Pond Cir Page 1 From: Joe Garcia To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Mitch... Date: 5/15/2008 12:38 PM Subject: Re: Calling for CO for 1706 Twin Pond Cir OK FOR CO. JMG >>> Terry Boriskie 04/24/08 10:49 AM >>> Contacted Donnie Sprague at 218-1918 about the problems. Terry Boriskie City of College Station Residential Plans Examiner Ofc.979-764-3744 Fax 979-764-3496 >>> Paul Schoenfeld 4/24/2008 9:33 am >>> NO for CO. Water meter lid broken box needs to be raised to grade. Sewer box needs to be raised to grade. Paul >>> Amber Carter 4/21/2008 8:18 AM >>> by 07-2812 Any issues? Date: 4/21/2008 Inspection Comments for Finals Permit Year: 7 Permit Number: 2812 Address: 1706 TWIN POND CIR Insp. Inspection Type Code Description p. status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC 10/03/2007 11:36 AM OC PDA B100 BLDG, FOUNDATION -SLAB IC drain lines not covered . B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed E110 ELEC, ROUGH IN IC 11/13/2007 04:19 PM RH PDA E110 ELEC, ROUGH IN IC Smoke detectors need a min.3f . from fan blades and a/c E110 ELEC, ROUGH IN IC vents. Lights at shower/tubs need to be suitable with E110 ELEC, ROUGH IN IC proper covers. By final. Page 1 WF0967767 / 001 City of College Station a + PAGE 1 REQ. DATE: 09/20/07 a 09/20/07 8:57:11 LOCATION: 1706 TWIN POND CIR LOC ID: 204092 REQUESTOR: DONOVAN HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 09/20/07 SCHED COMPLETION: 09/20/07 ******************************************************************************** JOB ORDER RESULT COMMENTS PREPARED 6/04/08, 7:59:53 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/03/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 1706 TWIN POND CIR SUBDIV: COVE OF NANTUCKET PH 1 CONTRACTOR DONOVAN HOMES PHONE (979) 690-6753 OWNER . . PHONE PARCEL . . 021001-0102-0350 APPL NUMBER: 07-00002812 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 02 10/03/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 10/03/07 AP October 3, 2007 11:52:45 AM kwolfe. Strings On Setbacks O.K. Slab Ground Installed B100 01 10/03/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 10/03/07 DP October 2, 2007 10:24:34 AM kwolfe 10/03/2007 11:36 AM OC PDA drain lines not covered . B115 01 11/14/07 OC BLDG, FRAMING TIME: 17:00 11/14/07 AP November 14, 2007 9:02:36 AM kwolfe. B130 01 11/16/07 OC BLDG, INSULATION TIME: 17:00 11/16/07 AP November 16, 2007 8:58:00 AM kwolfe. B125 01 4/21/08 BB BLDG, FINAL TIME: 17:00 4/21/08 DP April 18, 2008 3:01:19 PM glsouth. 04/21/2008 11:32 AM BB PDA Need to insulate attic. Need to post energy requirements in electrical panel. Skylight in hall bath nee to be completed. W irrigation. /'/`^/� B125 02 6/03/08 BI BLDG, FINAL TIME: 17:00 June 3, 2008 4:21:50 PM glsouth. KEY IS ABOVE THE `FRONT DDOR_ ----) -------------------------------------- COMMENTS AND NOTES ---------- -------- ---------------- BUILDING PERMIT CITY OF COLLEGE STATION COLLEGE STATION, TX 77840 1101 TEXAS AVENUE, PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 07-00002812 Date 9/15/07 Application pin number . . . 365908 Property Address . . . . . . 1706 TWIN POND CIR Property ID: 021001-0102-0350 R # Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 118536 Owner Contractor ------------------------ ------------------------ DONOVAN HOMES 5610 TIMBERLINE DR COLLEGE STATION TX 77845 (979) 690-6753 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A ' FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1796.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 447.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 525949 Permit Fee . . . . 517.00 Plan Check Fee .00 Issue Date . . . . 9/19/07 Valuation . . . . 118536 Expiration Date 3/17/08 Qty Unit Charge Per Extension BASE FEE 460.00 19.00 3.0000 THOU BLDG, VAL 10000.1-500000 57.00 ---------------------------------------------------------------------------- Special Notes and Comments -Narrow Wall Bracing Fully Sheathe3wii h 18"Minimum APA Garage Framing. ------ A.- ------ ------------- ---- - ----A� ----------- BUILDING DEP—REPR E ATI E: APPLICANT: 0 BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002812 Application pin number . . . 365908 Page 2 Date 9/19/07 Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front ) - ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULA ION BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840' PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00002812 Date 9/19/07 Application pin number . . . 365908 ---------------------------------------------------------------------------- Special Notes and Comments ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY',TOOL OR SPECIAL KNOWLEDGE/EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE ROM FO ED R - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - BUILDING DEP'PRZSE AT VE: APPLICANT: BUILDING PERMIT CITY OF COLI,.,EGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number 07-00002812 Date 9/19/07 Application pin number 365908 ---------------------------------------------------------------------------- Special Notes and Comments DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 2001 A .40 OR LOWER FACTOR AND ABOVE 200 TO 30% A .35 FACTO OR LOWER SHALL BE MET. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 517.00 517.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750 00 .00 .00 ------Grand -Total - 1267.00 ---126 00 00--��----��- ----------- - --- --- - -�-�- ----- BUILDING DEPT.--REPRES ATIV : APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-.3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 07-00002812 Application pin number . . . 365908 BUILDING DE APPLICANT: Page 5 Date 9/19/07 TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00002813 Date 9/19/07 Application pin number . . . 465967 Property Address . . . . . . 1706 TWIN POND CIR Property ID: 021001-0102-0350 R #. Application type description TEMP POLE Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ DONOVAN HOMES 5610 TIMBERLINE DR COLLEGE STATION TX 77845 (979) 690-6753 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit pin number . 525956 Permit Fee . . . . 20.00 Issue Date . . . . 9/19/07 Valuation 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited -------------------- Due Permit Fee Total 20.00 ---------- 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------- -------- - - - - - - - - - - - - ---------VAT --- ----- ---- BUILDING DE�'!r'iiEP�EIVE APPLICANT: * hr"" CITY OF COLLEGE $TATION P�annag:d Devi(opmeni'Seevicei: ADDRESS/LOCATION: APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOV DATE:%/ V L-% MC APPLICATION # TEMP POLE # v LOT �/ ✓ I/� ,ramT.! v BLOCK SUBDIVISION L _O F_ AT /�1 q!K BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: Ojl� Olyl PHONE: 2(P-'I . CONTACT PERSON FOR REVIEW COMMENTS- KjKjj FAQAF_ PHONE: \L FAX: I( l0 — (�15 J EMAIL: ELECTRICIAN: !;;5 & 0J HVAC: �i X:Lj0aVArt'1y'F_ PLUMBER: T4— " GOOD CENTS (Residential only): ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTIONSLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: PROPOSED USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) OJECT REGISTRATION# EABPRJ VALUATION: $ 3 TOTAL AREA: =a-� HEATED AREA:�� (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SEWER TAP�W WATER TAP.%V OTHER TAP: 1z TEMP POLE oro,,,bq GARAGE TYPE SINGLE ATTACHED NUMBER OF BEDROOMS: UMBER OF BATHROOMS INTERIOR WALL TYPE: 0 a EXTERIOR WALL TYPE: I1� ROOF TYPE: DOUBLE TRIPLE IET E CARPORT a SIGNATURE OF APPLICANT: %I-- __ VQ-1 a `If proposed work involves new commercial constrbqdo or facade commercial property, building elevations are required. Official Use Only -1 --o Plans Examiner -- eA.� Ut �1�2c4e rs Zoning Official zr_ ents: s:E or NO to an existing Fire Marshall G^.,� F;c" u 11V Energy Code Compliance Information % Glazing of exterior walls �. Y Insulation R value of exterior walls Insulation R value of ceiling 1 flat areas ( ) I p, Insulation R value of ceiling 2 (vaulted areas/no attic) 1 l Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork / A/C SEER Rating 13 / Protection Against Subterranean Termites /$TONE 6 1?---l-f. 6-01PF E hemical Termiticide Treatment (Soil Treatment) Chemical Termiticide Treatment (Field Applied Wood Treatment) 4 ❑ Physical Barriers ❑ Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. CITY OF COLLEGE STATION planning & Dn Iopmrnt Snwrct PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# �? Z DATE: _ BUILDING ADDRESS: �. e� I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement 10K F. Protection Method used for Termites. G. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species I B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck WAJOK E. Header sizes indicated on plans NA/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs location indicated on plans must have the size, grade & CITY OF COLLEGE STATION Planning 6- Dr Iopmrnt Seruita PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK OK A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8n & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N AT 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi NA/ B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window LI-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N K Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NAMLI Does not block any water course or divert any flow ;;0 �K Elevation certificate needed "APPROVED PLANS PER IRC SECTION R106.3.1." CITY OF COLLEGE STATION Planning b Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX e PLANS EXAMINER DATE