Loading...
HomeMy WebLinkAboutRES2007-02797, 07-2798PREPARED 4/18/08, 12:03:12 INSPECTION TICKET . PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/18/08 ------------------------------------------------------------------------------------------------ ADDRESS 4220 ROCKY RHODES DR SUBDIV: CASTLE ROCK CONTRACTOR CROWLEY CONSTRUCTION PHONE (979) 777-0285 OWNER . . PHONE PARCEL . . 184100-0170-0180 APPL NUMBER: 07-00002797 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 9/26/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 9/26/07 AP September 26, 2007 8:3.0:13 AM ACARTER. Strings On Setbacks O.K. Slab Ground Installed B145 01 11/19/07 RH BLDG, FRAMING TIME: 17:00 11/26/07 AE November 19, 2007 4:26:56 PM kwolfe. 11/26/2007 11:14 AM RH PDA Tape seal all penetrations through tyvek by insulation. B130 01 11/26/07 OC BLDG, INSULATION TIME: 17:00 11/26 7 AP November 26, 2007 11:35:28 AM kwolfe. B125 Ol 4/18/08 BI BLDG, FINAL TIME: 17:00 ri April 18, 2008 11:24:39 AM glsouth. -------------------------------------- COMMENTS AND NOTES --------/------------------------------ 0�' Date: 4/18/2008 Inspection Comments for Finals Permit Year: 7 Permit Number: 2797 Address: 4220 ROCKY RHODES DR Insp. inspection Type code p. Status Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B115 BLDG, FRAMING IC 11/26/2007 11:14 AM RH PDA B115 BLDG, FRAMING IC Tape seal all penetrations through tyvek by insulation. M110 MECH, FINAL IC April 18, 2008 11:22:11 AM glsouth. P125 PLBG, FINAL IC April 18, 2008 11:22:40 AM glsouth. Page 1 WF0966778 / 001 City of College Station PAGE 1 REQ. DATE: 09/17/07 -09/17/07 13:11:35 LOCATION: 4220 ROCKY RHODES DR LOC ID: 209650 REQUESTOR: CROWLEY CONSTRUCTION ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:. SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 09/17/07 SCHED COMPLETION: 09/17/07 ******************************************************************************** JOB ORDER RESULT CONIlKE TTS 1 City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . . . Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved . . . . . . . 4/23/08 184100-0170-0180 4220 ROCKY RHODES DR COLLEGE STATION TX 77845 CASTLE ROCK CASTLEROCK PH lA BLK 7 LOT 18 PLANNED DEVL DISTRICT CROWLEY CONSTRUCTION 979 777-0285 07-00002797 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX I//l A Bu icia VOID UNLESS SIGNED BY BUILDING OFFICIAL L■ N66'3634V ROCKY RHODES DRIVE &W PLAN A0002" IO=Y f*4=66 ORI '*"v * CAGTLERO= 6"' COLLEGE STATION CROWLSY CONSIWXTION LM, 1e Ism , d"Nu tA C+oULKrn � TEXA6 T0'd wv ZT=T0 400Z-vT-d3S ol NY &,jz-3y. DATE: T Ter rite & Peest Control Services P.lDEt60JPT-II0N u vuii rL ............. MW�e ali.qpqcks paysable N.I.-Accurate Termite and'Pe,$t a Control er&f?.U-0� YPOI Campleflix) 6U.SeNices rendered, VICE'CHARGE AQPEO-IF PAYIM ENT NOT FtECEINfED WITHIN 30 T - E DATE OF THII;'INVOfCE DAYS OF'I 14 LI C w r A t TIE:$[ QvcrindivWuqjs firxnscd byfl!C Round klthc Act. THANK You r�Qvyot)R L Accurate Termite & Pest Control Robert & Michelle Pro ft 13253 Hwy 30 F; Anderson, TX 77830 (936) 874-3034 877-796-9125 " r TPCL# 11588 3 Re: Dear ,QIZ& This letter and enclosed information is for your records concerning the soil treatment for sub�grraflean WMites at your contract site_19cated at Treatment was We applied one(1) gallon of chemical to every ten(10) square feet of slab area. We applied four(4) gallons of chemical per ten(10) linear feet of the perimeter. Extra chemicVa s plied argy nd all water drainage pipes. We used — mixed with water to form a olution. After all landscaping has been done around the perimeter of the structure, please call and we will trench and treat the outside. Please see attatched label and consumer information sheet for additional information. Our work is guaranteed for a period of five(S) years frome the date of initial treatment, with inspections made annually at a cost of $ plus tax per year. Should you decide not to carry the contract, the initial treatment is guaranteed only for one (1) year from date of treatment. Should any reinfestation occur during the term of the contract, we will retreat at no additional charge, providing that the contract is kept current. The contract is transferable to new owners if the property is sold during the life of the contract and all annual inspections are current. Exclusion: Accurate Termite & Pest Control will not be held responsible for any "previous" or "future" structural damage. If you wish to carry the contract, please sign the copy of the attatched contract and return it to my office. The guarantee will be void if the soil is disturbed after the chemical has been applied. For best results in preventing reinfestation, do not stack wood against the foundation. The cost of treatment wasS per square foot. Total cost was 3�0 plus sales tax of $ ,'2 dP.o—, for a total of $ Jg�e, Zb based on 6gg�Q square feet of slab. Signed and a ei on by bothLaarties in the contract this '_07YX� day of , 20 Purchaser _ Accurate Ter, & P Control By. LTitle: Thank you for choosing our company to take care of your pest control needs Structural Pest Control Board P.O. BOX 1927 Austin, Texas 78767-1927 (512) 305-8250 The board has jurisdiction over individuals licensed by the board and the act. SUBTERN NEAN TERMITE PRE-CONSTRUCTION.TRE TMENT DISCLOSURE FOR EACH ESTIMATE — PEST CONTROL COMPANY: Licensed and regulated under the Texas Structural Pest Control Ac Name: ACCi_1RATE TERMITE Sr PEST CONTROL TPCL No. 11588 Phone #: CM6) 874-3004 Address: 13253 HWY 30 City: - ANDERSON State: _� Zip Code: 77830 —9.VaI VMCK NFORMAI IVIV: Name: Phone #1: �� ' !'D T/� Phone #2: Address: City: State: Zip Code: For all treatments there will be a diagram showing exactly what will be treated. Treatment specifications and warranties for those treatments may vary widely. Review the pesticide label provided to you for minimum treatment specification. Remember that your architects or design engineer's specifications must also be followed, unless they are in violation of the law. If you have any questions, contact the pest control company or the Texas Structural Pest Control Board, P.O. Box 1927, Austin, TX 78767-1927. Telephone number (512) 305-8250. Before conducting a termite pre -construction treatment, the company will present a complete diagram of the structure including construction details. When construction prevents performance of a full treatment, in accordance with a bid for full treatment, any change to a partial treatment by the company providing treatment will be permitted if the owner of the structure or the person in charge of the construction and the certified applicator for the pest control company sign a statement attesting to the construction conditions. The agreement must be attached to the contract with an amended diagram showing the exact areas to be treated. Copies must be sent to the owner of the property and to the Structural Pest Control Board within seven days of the application. notes: Type of treatment proposed: (see other side of this page) O Full UPTrItial Total square feet to be treated:. Total linear feet to be treated: e_zl'�%. Approximate measurements of structure(s) to be treated: A label of �l " "T' termiticide(s) is attached. The concentration of the termiticide(s) to be applied is ��— %. Estimated amount of termiticide to be applied: llon(s). THE SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE IS ATTACHED ON BACK (SPCB/D-2).THE BOARD APPROVED SUBTERRANEAN TERMITE PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUCTION TREATMENT SERVICE. Complete details of warranty (if any) including time period of warranty, renewal options and cost, and obligations of the contracting parties is attached. ALthe warranty does not include the entire.structure treated, t ar@ s included in the warranty are: (specify) A consumer information sfieet is a &E tt of C or Technician Printed Name WDat� Signature of Customer Verifying Receipt of This Docu ent Date 340-2 • revised aww2 White Copy - Service Provider Yellow Copy - Customer Form Design 8 PdnBng by ServieeMark Communications 14166-782.6275, Dallas, TX 0 2002 _r BUILDING PERMIT_ a CITY OF COLLEGE.STATIOlf 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX-:-'(979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 07-00002797 Date 9/17/07 Application pin number . . . 811571 Property Address . . . . . . 4220 ROCKY RHODES DR Property ID: 184100-0170-0180 R #• Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLE ROCK PH lA Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL DISTRICT Application valuation . . . . 150000 Owner Contractor ------------------------ ------------------------ CROWLEY CONSTRUCTION 4714 WILLIAMS CREEK DR COLLEGE STATION TX 77845 (979) 777-0285 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2076.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 441.00 ---------------------------------------------------------------------------- Permit . . . . . BUILDING PERMIT Additional desc . . MA Permit pin number . 525253 Permit Fee . . . . 610.00 Plan Check Fee .00 Issue Date . . . . 9/17/07 Valuation . . . . 150000 Expiration Date . . 3/15/08 Qty Unit Charge Per Extension BASE FEE 460.00 50.00 3.0000 THOU BLDG, VAL 100001-500000 150.00 ---------------------------------------------------------------------------- Special Notes and Comments -2nd Floor Windows to be at least 24" A.F.F. -Narrow Wall Bracing Fully Sheathed with m dified rear porch ----------------------------------------------- BUILDING DEPT R, 2 -----�--- ESENTATIVE: ---.--'-------- APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION` 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002797 Application pin number . . . 811571 Page 2 Date 9/17/07 Special Notes and Comments area to allow 33" OSB per plans. ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. Garage ceiling must have 5/8" Type X sheetrock when there is Habitable'space above the garage. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) -----------------------------------------------L--- -�:.i --�__------- BUILDING DEPT B7ESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002797 Application pin number . . . 811571 Page 3 Date 9/17/07 Special Notes and Comments ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed,Over A11'Exterior Sheathing Per 2006 IRC Section R703.2 THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN PRESSURE REDUCING VALVE SHALL BE PROVIDED MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING BUILDING DEPT TIVE: APPROVED THAT LIMITS THE ENVELOPE SHALL _46------- APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 07-00002797 Date 9/17/07 Application pin number . . . 811571 ---------------------------------------------------------------------------- Special Notes and Comments BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC ) RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC -------------------------------------------------�'- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING.PERMIT , ' CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX-77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 07-00002797 Date 9/17/07 Application pin number . . . ---------------------------------------------------------------------------- 811571 Special Notes and Comments IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE ROOM. ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged --------------------------- Paid Credited Due Permit Fee Total 610.00 ------------------------------ 610.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1360.00 1360.00 .00 .00 ------------------------------------------------`-----�. ---.4-- -- -------- BUILDING DEPT R5AD-RESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT ' CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 --------------------'-------------------------------------------------------- Application Number . . . . . 07-00002798 Date 9/17/07 Application pin number . . . 954514 Property Address . . . . . . 4220 ROCKY RHODES DR Property ID: 184100-0170-0180 R #. Application type description TEMP POLE. Subdivision Name . . . . . . CASTLE ROCK PH lA Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL DISTRICT Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ CROWLEY CONSTRUCTION 4714 WILLIAMS CREEK DR COLLEGE STATION TX 77845 (979) 777-0285 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc MA Permit pin number 525261 Permit Fee . . . . 20.00 Issue Date . . . . 9/17/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited -------------------- Due Permit Fee Total 20.00 ---------- 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 00 ----------------------------------------------� ----� -- --------- BUILDING DEP3_-R4,�ESENTATIVE: APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning & Develepment Service WWW.CSTX.GOV ADDRESS/LOCATION: +OW a&q ' For Office Use Only DATE: • • V RCC I APPLICATION # TEMP POLE # 1 • LOT G,� BLOCK SUBDIVISION CC-t `�"12Q'O G`ti '� SEC/PH_I A BUSINESS/OWNER NAME: (,C�CJw�C� ����, PHONE: CONTRACTOR/HOMEOWNER: PHONE: CONTACT PERSON FOR REVIEW COMMENTS: �� cro"i�PHONE: FAX: (970 -7�;5-2S- ELECTRICIAN: HVAC: EMAIL: CN-br Ir--i-Q C ro W �egC-'Ck?c, PLUMBER: C? GOOD CENTS (Residential only): �eEct> ACCESSORY/STORAGE MOVING RE -ROOF ADDITION NEW CONSTRUCTION* SHELL ONLY DEMOLITION (ASBESTOS SURVEY) PORTABLE STORAGE (RESIDENTIAL) SLAB ONLY DUPLEX (LANDSCAPE PLANS REQUIRED) PORTABLE STORAGE (NON-RESIDENTIAL) SWIMMING POOL LOCATION REMODEL/RENOVATION" DESCRIPTION OF WORK:-UQ0APb"% !•c�1v� n PROPOSED USE:��� STRUCTURE USE: HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ (,!�b, cc2c, TOTAL AREA: HEATED AREA: Z"7 (Cost of Labor and Materials) Zg3a PUBLIC SEWER NUMBER OF BEDROOMS: (� ❑ SEPTIC/TREATMENT SYS M NUMBER OF BATHROOMS: r SE R INTERIOR WALL TYPE: � e \ ` WAT OIL�;XTERIOR WALL TYPE:t t�G SIZE OTHE AP: ��• FOUNDATION TYPE: �e sl � �]C TEMP P6 ROOF TYPE: GARAGE TYPE: LE a DOUBLE TRIPLE a ATTACHED DETACHED a CARPORT a SIGNATURE OF APPLICANT: ' If proposed work involves new commer ' onstruction o faca i rovements/r novatio to an existing commercial property, building elevations are required. ............................................................ Official Use Only —/ —0 Comments: 4tZrNO QP Plans Examiner 4A4 ,Zpning Official �t�..� ins 14y" MA/ . AG'r J MWf sae BmlrwL zrrtn isA w • Air EnergyaCode Compliance Information I _ , Glazing of exterior walls- ��- �� , . "� �, , � _ � , o ' Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) IN 3 .,/ Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient)U Glazing U-Factor S R value of ductwork A/C SEER Rating Protection Against Subterranean Termites 60 Chemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other * Verification of Application shall be submitted to the City of College Station Building Division prior to issuance of the Certificate of Occupancy. CITY OF COLLEGE STATION Planning d Development Servien PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# _ DATE: BUILDING ADDRESS: ..nn d Kdck:�Zh NQ I. Foundation Requirements- Minimum City Foundation Stl3ndards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 6mil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, rade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduce span) O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans CITY OF COLLEGE STATION Planning d Development Service; PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX Q. Tempered Glass required in all hazardous locations R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK &MOK A. Stairway Details N K 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1 /2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NA/ 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required CITY OF COLLEGE STATION Planning d-De Iopment Simko PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NA/ K Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow Elevation certificate needed WOK "APPROVED PLANS PER IRC SECTION R106.3.1." tf CITY OF COLLEGE STATION Planning& Dnalopmont&mira PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX � 12ou 4, 9 - 1 �-07 PLANS EXAMINER DATE