Loading...
HomeMy WebLinkAboutMF2007-02792Date _-- Permit # 74 Project Name COMMERCIAL CO Planning (Lindsay Boyer, Jennifer Prochazka,'Jennifer Reeves, Crissy Hartl, Jason Schubert Grant Wencel, Molly Hitchcock) Bridgette George Development Engineers (Alan Gibbs, Josh Norton, Carol Cotter) City Engineer (Bob Mosley, Jerry Jones, John Logan, Robert Bumpurs, William Ethridge) Environmental Services (Eaphrame Thomas, James Boykin, Pete Garcia) Fire Department (Eric Hurt, Eric Dotson, Jerry Duffey, Steve Smith) Drainage (Donnie Willis) Public Works - Sanitation (Wally Urrutia) Electrical Services (Tony Michalsky) Water/VVastewater Services (Joe Mike Garcia, Paul Schoenfeld, Mitchell Carson) Miscellaneous Notes WF0972404 / 001 City of Collegs.-Stat.ion PAGE 1 REQ. DATE: 10/09/07 10/09/07 9:32:21 LOCATION: 1725 HARVEY MITCHELL PKWY S 5211 LOC ID: 207084 REQUESTOR: DOVETAIL BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/09/07 SCHED COMPLETION: 10/09/07 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0972406 / 001 City of College Station PAGE 1 REQ. DATE: 10/09/07 10/09/07 9:32:51 LOCATION: 1725 HARVEY MITCHELL PKWY S 5212 LOC ID: 207092 REQUESTOR: DOVETAIL BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/09/07 SCHED COMPLETION: 10/09/07 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0972409 / 001 City of College Station PAGE 1 REQ. DATE: 10/09/07 10/09/07 9:33:22 LOCATION: 1725 HARVEY MITCHELL PKWY S 5213 LOC ID: 207100 REQUESTOR: DOVETAIL BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/09/07 SCHED COMPLETION: 10/09/07 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0972413 / 001 City of College Station PAGE 1 REQ. DATE: 10/09/07 10/09/07 9:35:36 LOCATION: 1725 HARVEY MITCHELL PKWY S 5221 LOC ID: 207088 REQUESTOR: DOVETAIL BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/09/07 SCHED COMPLETION: 10/09/07 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0972414 / 001 City of College Station PAGE 1 REQ. DATE: 10/09/07 10/09/07 9:36:14 LOCATION: 1725 HARVEY MITCHELL PKWY S 5222 LOC ID: 207090 REQUESTOR: DOVETAIL BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/09/07 SCHED COMPLETION: 10/09/07 JOB ORDER RESULT COMMENTS WF097241G / 001 City of College Station PAGE 1 REQ. DATE: 10/09/07 10/09/07 9:36:44 LOCATION: 1725 HARVEY MITCHELL PKWY S 5223 LOC ID: 207096 REQUESTOR: DOVETAIL BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/09/07 SCHED COMPLETION: 10/09/07 JOB ORDER RESULT COMMENTS WF0972421 / 001 City of College Station PAGE 1 REQ. DATE: 10/09/07 10/09/07 9:38:25 LOCATION: 1725 HARVEY MITCHELL PKWY S 5224 LOC ID: 207098 REQUESTOR: DOVETAIL BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/09/07 SCHED COMPLETION: 10/09/07 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0972423 / 001 City of College Station PAGE 1 REQ. DATE: 10/09/07 10/09/07 9:38:54 LOCATION: 1725 HARVEY MITCHELL PKWY S 5225 LOC ID: 207102 REQUESTOR: DOVETAIL BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/09/07 SCHED COMPLETION: 10/09/07 JOB ORDER RESULT COMMENTS WF0972424 / 001 City of College,Station PAGE 1 REQ. DATE: 10/09/07 10/09/07 9:39:23 LOCATION: 1725 HARVEY MITCHELL PKWY S 5226 LOC ID: 207104 REQUESTOR: DOVETAIL BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH'USER:ACARTER WRK TYPE: WTR 3/4" TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/09/07 SCHED COMPLETION: 10/09/07 ******************************************************************************** JOB ORDER RESULT COMMENTS City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 T E M P O R A R Y C O T E M P O R A R Y Issue Date . . . . . . Expiration Date . . . . Parcel Number . . . . . Property Address Subdivision Name Legal Description Property Zoning Owner . . . . . . . . Contractor 7/29/08 9/05/08 000701-0104-0000 1725 HARVEY MITCHELL PKWY S BL 52 COLLEGE STATION TX 77840 CRAWFORD BURNETT (ICL) A000701 CRAWFORD BURNETT (ICL) , TRACT 104, ACRES 75.93 APARTMENT LOW DENSITY WOODLANDS OF COLLEGE STATION DOVETAIL BUILDERS 706 357-9100 Application number 07-00002792 000 000 Description of Work RESIDENTIAL, 5+ UNITS NEW Construction type COMBUSTIBLE (PROTECTED) Occupancy type RESIDENTIAL -MULTI -FAMILY Flood Zone Special conditions 1. ESTABLISH GROUNDCOVER OVER ALL DISTURBED EARTH. Approved J A Building Official_ VOID UNLESS SIGNED BY BUILDING OFFICIAL City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 T E M P O R A R Y C O T E M P O R A R Y Issue Date . . . . . . Expiration Date . . . . Parcel Number . . . . . Property Address . . . Subdivision Name Legal Description Property Zoning . . . Owner . . . . . . . . Contractor 7/29/08 8/29/08 000701-0104-0000 1725 HARVEY MITCHELL PKWY S BL 52 COLLEGE STATION TX 77840 CRAWFORD BURNETT (ICL) A000701 CRAWFORD BURNETT (ICL) , TRACT 104, ACRES 75.93 APARTMENT LOW DENSITY WOODLANDS OF COLLEGE STATION DOVETAIL BUILDERS 706 357-9100 Application number 07-00002792 000 000 Description of Work RESIDENTIAL, 5+ UNITS NEW Construction type . . . COMBUSTIBLE (PROTECTED) Occupancy type . . . . RESIDENTIAL -MULTI -FAMILY Flood Zone . . . . . . Special conditions . . 1. ESTABLISH GROUNDCOVER OVER ALL DISTURBED EARTH. Approved c9 A1. Building Official VOID UNLESS SIGNED BY BUILDING OFFICIAL City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 T E M P O R A R Y C O T E M P O R A R Y Issue Date . . . . . . 7/29/08 Expiration Date 8/13/08 Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning 000701-0104-0000 1725 HARVEY MITCHELL PKWY S BL 52 COLLEGE STATION TX 77840 CRAWFORD BURNETT (ICL) A000701 CRAWFORD BURNETT (ICL) TRACT 104, ACRES 75.93 APARTMENT LOW DENSITY Owner . . . . . . . . . WOODLANDS OF COLLEGE STATION Contractor . . . . . . DOVETAIL BUILDERS 706 357-9100 Application number 07-00002792 000 000 Description of Work RESIDENTIAL, 5+ UNITS NEW Construction type . . . COMBUSTIBLE (PROTECTED) Occupancy type . . . . RESIDENTIAL -MULTI -FAMILY Flood Zone . . . . . . Special conditions . . 1. DRAINAGE ISSUE MUST BE CORRECTED WITH CITY ENGINEER. 2. KNOX SWITCH FOR THE SECOND GATE NEEDS TO BE INSTALLED. Approved . . . . . . . VOID UNLESS SIGNED BY BUILDING OFFICIAL M- a-79,;L U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE OMB No. 1660-0008 Federal Emergency Management Agency I EXDireS February 28. 2009 National Flood Insurance Program Important: Read the instructions on pages 1-8. SECTION A - PROPERTY INFORMATION For Insurance Company Use: Al. Building Owner's Name DOVETAIL DEVELOPMENT LLC Policy Number A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Company NAIC Number 1725 HARVEY MITCHELL PARKWAY, COTTAGE 52 City COLLEGE STATION State TX ZIP Code 77840 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) PLAT OF THE WOODLANDS OF COLLEGE STATION A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) MULTI -FAMILY RESIDENTIAL A5. Latitude/Longitude: Lat. 30°35'21.24"N Long. 96°19'16.09"W Horizontal Datum: ❑ NAD 1927 X NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1 A8. For a building with a crawl space or enclosure(s), provide A9. For a building with an attached garage, provide: a) Square footage of crawl space or enclosure(s) sq ft a) Square footage of attached garage sq ft b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage enclosure(s) walls within 1.0 foot above adjacent grade walls within 1.0 foot above adjacent grade c) Total net area of flood openings in A8.b sq in c) Total net area of flood openings in A9.b sq in SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State CITY OF COLLEGE STATION 480083 BRAZOS I TX B4. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone Date Effective/Revised Date Zone(s) AO, use base flood depth) 48041 CO182 C 2-9-2000 LOMR Effective Date AE-1 % Annual LOMR Case No. 06-06- 3-29-2007 Chance 100 yr B753P Flood lain B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile ❑ FIRM ❑ Community Determined X Other (Describe) LOMR Bl 1. Indicate elevation datum used for BFE in Item 69: X NGVD 1929 ❑ NAVD 1988 ❑ Other (Describe) B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑Yes X No Designation Date ❑ CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings' Building Under Construction' x Finished Construction New Elevation Certificates will be required when the slab is poured and when construction of the building is complete. C2. Elevations -Zones Al-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-g below according to the building diagram specified in Item A7. Benchmark Utilized SEE BELOW Vertical Datum NGVD-29 Conversion/Comments BASED ON THE CITY OF COLLEGE STATION HORIZONTAL CONTROL MONUMENT NOA 19, ELEVATION=279.76 Check the measurement used. a) Top of bottom floor (including basement, crawl space, or enclosure floor)_ 285.1 X feet ❑ meters (Puerto Rico only) b) Top of the next higher floor ❑ feet ❑ meters (Puerto Rico only) c) Bottom of the lowest horizontal structural member (V Zones only) ❑ feet ❑ meters (Puerto Rico only) d) Attached garage (top of slab) ❑ feet ❑ meters (Puerto Rico only) e) Lowest elevation of machinery or equipment servicing the building ❑ feet ❑ meters (Puerto Rico only) (Describe type of equipment in Comments) f) Lowest adjacent grade (finished) (LAG) 284.6 x feet ❑ meters (Puerto Rico only) g) Highest adjacent grade (finished) (HAG) 285.0 x feet ❑ meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. ❑ Check here if comments are provided on back of form. Certifier's Name GREGORY HOPCUS License Number 6047 Title REGISTERED PROFESSIONAL LAND SURVEYOR Company Name GOODWIN LASITER, INC Address 3600 STATE HWY 6 SOUTH, STE. 102 City COLLEGE STATION State TX ZIP Code 77845 o• o, 00:0,"o so GREG RTCUS ofo�oaeomom®rc.na�c? Jfl �� �q 6047- �,'j FEMA Form 81-31, February 2006 Date 7-23-2008 teiepnone 9(9/696-6/b/ See reverse side for continuation. Replaces all previous editions (7/2912008) Gina Southerland „Ok for Temp CO on buildings 39, 50 53 _ ,__.___.__....... _ ...._...._ _.__.. _. Page. 1. From: Donnie Willis To: Southerland, Gina Date: 7/29/2008 3:28 PM Subject: Ok for Temp CO on buildings 39, 50-53. Ok for Temp CO on buildings 39, 50-53. Donnie Willis, CFM Environmental Engineering Technician Certified Floodplain Manager Public Works Department 979-764-6375 office 979-229-7632 cell dwillis@cstx.gov (7/29/2008) Amkier Carter - Re Calling for CO for 1725 H. Mitchell BI 31 39 and 48 53 Page 1 From: Eric Dotson To: Alan Gibbs; Amber Carter; Benjamin McCarty; Brenda Godfrey; Bridgett... Date: 7/23/2008 2:10 PM Subject: Re: Calling for CO for 1725 H. Mitchell BI 31-39 and 48-53 Good for Temp CO all they need is to install the gate Knox Key on the second entrance when it is delivered all other issues have been resolved. Eric Dotson '06 Deputy Fire Marshal College Station Fire Department edotson@cstx.gov (979)764-3709 (979)764-3705 Fax (979)764-3403 >>> Amber Carter 7/9/2008 4:47 PM >>> This should include the last of the buildings for the Woodlands. Contact: Justin Randall @ 706-215-1868 Owner: Woodlands of College Station Thanks! V 1 U.S. DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency National Flood Insurance Program ELEVATION CERTIFICATE Important: Read the instructions on pages 1-8. OMB No. 1660-0008 Expires February 28. 2009 SECTION A - PROPERTY INFORMATION For Insurance Company Use: Al. Building Owner's Name DOVETAIL DEVELOPMENT LLC Policy Number A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. I Company NAIC Number I 1725 HARVEY MITCHELL PARKWAY, COTTAGE 52 City COLLEGE STATION State TX ZIP Code 77840 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) PLAT OF THE WOODLANDS OF COLLEGE STATION A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) MULTI -FAMILY RESIDENTIAL A5. Latitude/Longitude: Lat. 30°35'21.24"N Long. 96°19'16.09'W Horizontal Datum: ❑ NAD 1927 X NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1 A8. For a building with a crawl space or enclosure(s), provide A9. For a building with an attached garage, provide: a) Square footage of crawl space or enclosure(s) sq ft a) Square footage of attached garage sq ft b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage enclosure(s) walls within 1.0 foot above adjacent grade walls within 1.0 foot above adjacent grade c) Total net area of flood openings in A8.b sq in c) Total net area of flood openings in A9.b sq in SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State CITY OF COLLEGE STATION 480083 BRAZOS TX 71 B4. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone Date Effective/Revised Date Zone(s) AO, use base flood depth) 48041 CO182 C 2-9-2000 LOMR Effective Date AE-1 % Annual LOMR Case No. 06-06- 3-29-2007 Chance 100 yr B753P Flood lain B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile ❑ FIRM ❑ Community Determined X Other (Describe) LOMR B11. Indicate elevation datum used for BFE in Item B9: X NGVD 1929 ❑ NAVD 1988 ❑ Other (Describe) B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑Yes X No Designation Date ❑ CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings` Building Under Construction" x Finished Construction New Elevation Certificates will be required when the slab is poured and when construction of the building is complete. C2. Elevations - Zones Al-A30, AE, AH, A (with BFE), VE, V1430, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-g below according to the building diagram specified in Item A7. Benchmark Utilized SEE BELOW Vertical Datum NGVD-29 Conversion/Comments BASED ON THE CITY OF COLLEGE STATION HORIZONTAL CONTROL MONUMENT NOA 19, ELEVATION=279.76 Check the measurement used. a) Top of bottom floor (including basement, crawl space, or enclosure floor)_ 285.1 X feet ❑ meters (Puerto Rico only) b) Top of the next higher floor ❑ feet ❑ meters (Puerto Rico only) c) Bottom of the lowest horizontal structural member (V Zones only) ❑ feet ❑ meters (Puerto Rico only) d) Attached garage (top of slab) ❑ feet ❑ meters (Puerto Rico only) e) Lowest elevation of machinery or equipment servicing the building ❑ feet ❑ meters (Puerto Rico only) (Describe type of equipment in Comments) f) Lowest adjacent grade (finished) (LAG) 284.6 x feet ❑ meters (Puerto Rico only) g) Highest adjacent grade (finished) (HAG) 285.0 x feet ❑ meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. a. ❑ Check here if comments are provided on back of form. Certifier's Name GREGORY HOPCUS License Number 6047 Title REGISTERED PROFESSIONAL LAND SURVEYOR Company Name GOODWIN LASITER, INC 6047Address 3600 STATE HWY 6 SOUTH, STE. 102 City COLLEGE STATION State TX ZIP Code 77845VIC �;0�..�� �C?'� j D�-2�GZ r. `•, �= , IMPORTANT: In these spaces, copy the corresponding information from Section A. For Insurance Company Use: Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 1725 HARVEY MITCHELL PARKWAY, COTTAGE 52 City COLLEGE STATION State TX ZIP Code 77840 Company NAIC Number SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. Comments _Z _p Signature Date ❑ Check here if attachments SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items El-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B, and C. For Items E1-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-8 with permanent flood openings provided in Section A Items 8 and/or 9 (see page 8 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8. and G9. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4.-G9.) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: ❑ feet ❑ meters (PR) Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters (PR) Datum Local Official's Name Title Community Name Telephone Signature Date Comments ❑ Check here if attachments FEMA Form 81-31, February 2006 Replaces all previous editions Building Photographs See Instructions for Item A6. FRONT VIEW BUILDING 52 FACING SOUTHWEST TAKEN 7-22-08 BACK VIEW BUILDING 52 FACING SOUTHEAST TAKEN 7-22-08 Building Photographs Continuation Page For Insurance Company Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. I Policy Number City State ZIP Code I Company NAIC Number If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." BUILDING 52 FACING NORTHEAST 7-22-08 6AC4 VICO BUILDING 52 FACING NORTHWEST 7-22-08 F�ovr v1 W U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE OMB NO. 1660-0008 ExOires February 28. 2009 Federal Emergency Management Agency ' National Flood Insurance Program Important: Read the instructions on pages 1-8. SECTION A - PROPERTY INFORMATION For Insurance Company Use: Al. Building Owner's Name DOVETAIL DEVELOPMENT LLC Policy Number A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. I Company NAIC Number I 1725 HARVEY MITCHELL PARKWAY, COTTAGE 52 City COLLEGE STATION State TX ZIP Code 77840 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) PLAT OF THE WOODLANDS OF COLLEGE STATION A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) MULTI -FAMILY RESIDENTIAL A5. Latitude/Longitude: Lat. 30°35'21.24"N Long. 96°19'16.09'W Horizontal Datum: ❑ NAD 1927 X NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1 A8. For a building with a crawl space or enclosure(s), provide A9. For a building with an attached garage, provide: a) Square footage of crawl space or enclosure(s) sq ft a) Square footage of attached garage sq ft b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage enclosure(s) walls within 1.0 foot above adjacent grade walls within 1.0 foot above adjacent grade c) Total net area of flood openings in A8.b sq in c) Total net area of flood openings in A9.b sq in SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State CITY OF COLLEGE STATION 480083 1 BRAZOS I TX B4. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone Date Effective/Revised Date Zone(s) AO, use base flood depth) 48041 CO182 C 2-9-2000 LOMR Effective Date AE-1 % Annual LOMR Case No. 06-06- 3-29-2007 Chance 100 yr B753P Flood lain 610. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile ❑ FIRM ❑ Community Determined X Other (Describe) LOMR B11. Indicate elevation datum used for BFE in Item 69: X NGVD 1929 ❑ NAVD 1988 ❑ Other (Describe) B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑Yes X No Designation Date ❑ CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings' X Building Under Construction' ❑ Finished Construction New Elevation Certificates will be required when the slab is poured and when construction of the building is complete. C2. Elevations - Zones Al-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-g below according to the building diagram specified in Item A7. Benchmark Utilized SEE BELOW Vertical Datum NGVD-29 Conversion/Comments BASED ON THE CITY OF COLLEGE STATION HORIZONTAL CONTROL MONUMENT NO.119. ELEVATION=279.76 Check the measurement used. a) Top of bottom floor (including basement, crawl space, or enclosure floor)_ 285.1 X feet ❑ meters (Puerto Rico only) b) Top of the next higher floor ❑ feet ❑ meters (Puerto Rico only) c) Bottom of the lowest horizontal structural member (V Zones only) ❑ feet ❑ meters (Puerto Rico only) d) Attached garage (top of slab) ❑ feet ❑ meters (Puerto Rico only) e) Lowest elevation of machinery or equipment servicing the building ❑ feet ❑ meters (Puerto Rico only) (Describe type of equipment in Comments) f) Lowest adjacent grade (finished) (LAG) 284.6 x feet ❑ meters (Puerto Rico only) g) Highest adjacent grade (finished) (HAG) 285.0 x feet ❑ meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. ❑ Check here if comments are provided on back of form. Certifier's Name GREGORY HOPCUS License Number 6047 Title REGISTERED PROFESSIONAL LAND SURVEYOR Company Name GOODWIN LASITER, INC Address 3600 STATE HWY 6 SOUTH, STE. 102 City COLLEGE STATION State TX ZIP Code 77845 GREGORY Nui'CUS �saososesseosr. naa�4aa� / �'O/► 60,6i •''' a 4e-FS r�40 asap© gnature Date Coo ra% orco cirio fnr rnntini intinn Rpnitlr:p.S ;;II nrpvious editions IMPORTANT: In these spaces, copy the corresponding information from Section A. For Insurance Company Use: Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number 1725 HARVEY MITCHELL PARKWAY, COTTAGE 52 City COLLEGE STATION State TX ZIP Code 77840 Company NAIC Number SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. 7-z3 Signature 17(/ r Date ❑ Check here if attachments SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B, and C. For Items El-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-8 with permanent flood openings provided in Section A Items 8 and/or 9 (see page 8 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is El feet ❑ meters ❑ above or El below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8. and G9. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (indicate the source and date of the elevation data in the Comments area below.) G2. ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4.-G9.) is provided for community floodplain management purposes. G4. Permit Number I G5. Date Permit Issued I G6. Date Certificate Of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: _❑ feet ❑ meters (PR) Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters (PR) Datum Local Official's Name Title Community Name Telephone Signature Date Comments ❑ Check here if attachments FEMA Form 81-31, February 2006 Replaces all previous editions Building Photographs See Instructions for Item A6. For Insurance Company Use: Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number City State ZIP Code Company NAlCNumber If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page, following. FRONT VIEW BUILDING 52 FACING SOUTHWEST TAKEN 7-22-08 BACK VIEW BUILDING 52 FACING SOUTHEAST TAKEN 7-22-08 Building Photographs Continuation Page For Insurance Company Use: Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. I Policy Number City State ZIP Code If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." t x4 . BACK VIEW BUILDING 52 FACING NORTHEAST TAKEN 7-22-08 FRONT VIEW BUILDING 52 FACING NORTHWEST TAKEN 7-22-08 BUILDING,''PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX.77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 07-00002792 Date 10/02/07 Application pin number . . . 422896 Property Address . . . . . . 1725 HARVEY MITCHELL PKWY S BL 52 Property ID: 000701-0104-0000 R #: R10473 Tenant nbr, name . . . . . . APTS W/ 9 UNITS Application type description RESIDENTIAL, 5+ UNITS NEW Subdivision Name . . . . . . CRAWFORD BURNETT (ICL) Property Use . . . . . . . . Property Zoning . . . . . . . APARTMENT LOW DENSITY Application valuation . . . . 537240 Owner Contractor ------------------------ ------------------------ WOODLANDS OF COLLEGE STATION DOVETAIL BUILDERS LP 126 BRIARCLIFF RD STE 9 1550 TIMOTHY RD STE 201 ATHENS GA 30606 ATHENS GA 30606 (706) 357-9100 --- Structure Information 000 000 NEW MULTI -FAMILY DWELLING BUILDING Construction Type . . . . . COMBUSTIBLE (PROTECTED) Occupancy Type . . . . . . RESIDENTIAL -MULTI -FAMILY Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NA HEATED AREA 12099.00 INTERIOR WALL TYPE DRYWALL NUMBER OF BATHROOMS 27.00 NUMBER OF BEDROOMS 27.00 SEWER TYPE PUBLIC TAZ 373.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 528091 Permit Fee . . . . 1736.00 Plan Check Fee .00 Issue Date . . . . 10/02/07 Valuation . . . . 537240 Expiration Date . 3/30/08 Qty Unit Charge Per Extension BASE FEE 1660.00 38.00 2.0000 THOU BLDG, VAL 500001 & UP 76.00 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ADDRESS ON COMMERCIAL BUILDINGS -FRONT: 5" ADDRESS NUMBERS, AND ON REAR DOOR(S): 2" HIGH ADDRESS NUMBERS AND --------------------------- -A� -- -------------------- BUILDING DEPT REPRESENTATIVE: / APPLICANT: BUILDING,PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002792 Application pin number . . . 422896 Page 2 Date 10/02/07 Special Notes and Comments NAME OF BUSINESS. ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS PASSAGEWAY MAY HAVE TO BE ELEVATED TO ALLOW FOR REQUIRED R-VALUE ATTIC INSULATION. PROVIDE ATTIC ACCESS OPENING OF 20"x 30" WITH A CLEAR HEIGHT OF 30" MINIMUM HEADROOM IN THE ATTIC SPACE ABOVE THE ACCESS OPENING. PROVIDE ATTIC ACCESS WITHIN 20' OF APPLIANCES; EXCEPTION: PROVIDE ATTIC ACCESS WITHIN 50' OF APPLIANCES IF PASSAGEWAY IS UNOBSTRUCTED AND NOT LESS THAN 6' HIGH AND 22" WIDE FOR ITS ENTIRE LENGTH PER SECTION 306.3, 2006 IMC. Shall advertise only the name of, uses of, or goods or services available within the building, or tenant lease space, to which the banner is attached. Shall be mounted parallel to the face of the building. Shall not be cantilevered away from the structure. Shall not extend more than one foot from any exterior building face, mansard, awning, or canopy. Shall not obstruct any window, door, stairway, or other opening intended for ingress or for needed ventilation or light. Shall not be attached to any tree, fence, or public utility pole. NOTE FROM WATER DEPT--REDUCED PRESSURE ASSEMBLY REQUIRED FOR CAR WASH, POSTMIX CARBONATER, AND HEATING/AC WITH DIRECT CONNECTION TO WATER SUPPLY AND LAWN IRRIGATION SYSTEMS. ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD #2394. ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD#2394 ELECTRICAL UTILITIES COMMENTS DEVELOPER INSTALLS CONDUIT PER CITY SPECS & DESIGN DEVELOPER PROVIDES TEMP BLANKET EASEMENT FOR CONSTRUCTION DEVELOPER POURS TRANSFORMER PAD PER CITY SPECS (IF NECESSARY) DEVELOPER PROVIDES 30' RIGID CONUDIT FOR RISER POLE (IF NECESSARY) ________EUILDING_________DEtT ---- _REtRESENTATIVE: --------------- _______ ___�T____________________ 4 n APPLICANT: BUILDING,PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002792 Application pin number . . . 422896 Page 3 Date 10/02/07 Special Notes and Comments DEVELOPER INSTALLS FIRST 10' OF CONDUIT ON RISER POLE. CITY INSTALLS,REMAINING 201. DEVELOPER PROVIDES EASEMENTS FOR ELECTRIC INFRASTRUCTURE AS INSTALLED FOR ELECTRIC LINES. DEVELOPER PROVIDES DIGITAL SITE PLAN IN AUTOCADE 14 VERSION. EMAIL TO RBOLIN@CI.COLLEGE-STATION.TX.US DEVELOPER IS REPSONSIBLE FOR THE INSTALLATION OF SERVICE FROM TRANSFORMER TO BUILDING FOR QUESTIONS CONTACT RONNIE BOLIN AT 979-764-3614 PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE PROVIDE COMBUSTION AIR: FOR GAS -FIRED APPLIANCES PER SECTION 304 OF THE 2006 INTERNATIONAL FUEL GAS CODE; FOR OTHER FUELS TO COMPLY WITH CHAPTER 7 OF THE 2006 IMC. Underground electrical conduit installation shall be installed per city specs and is the responsibility of the owner and/or contractor. Contact the electrical division at (979) 764-6314 for more information. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELEVATION CERTIFICATE REQUIRED - PROVIDE ELEVATION CERTIFICATE PRIOR TO SLAB INSPECTION AND A SECOND CERTIFICATE PRIOR TO FINAL INSPECTION/C.O. ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR REQUIRED EXIT DOOR(S) SUBMIT FIRE ALARM PLANS WITH PRODUCT DATA SHEETS - DESIGN AND INSTALL AS PER NFPA 72 NO WORK SHALL START UNTIL PLANS HAVE BEEN REVIEWED AND RETURNED - APPLICANT: BUILDING•PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 07-00002792 Date 10/02/07 Application pin number . . . 422896 ---------------------------------------------------------------------------- Special Notes and Comments MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND SUBMIT FIRE SPRINKLER PLANS AND CALCULATIONS FOR REVIEW NO WORK ON SPRINKLER SYSTEM SHALL BEGIN UNTIL PLANS HAVE BEEN REVIEW AND RETURNED. SPRINKLER SYSTEM CONTROLS AND WATER FLOW SWITCHES ARE REQUIRED TO BE MONITORED BY AN APPROVED MONITORING COMPANY. A COPY OF THE MONITORING CONTRACT SHALL BE SENT TO THE COLLEGE STATION FIRE DEPARTMENT, FIRE PREVENTION DIVISION. GUARDS SHALL COMPLY WITH SECTION 1013 OF THE 2006 IBC. Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit HANDRAILS SHALL COMPLY WITH SECTION R-311 (2003 IRC) OR SECTION 1009 (2003 IBC) AS APPROPRIATE PROVIDE PROTECTION FOR STRUCTURES, DUMPSTER ENCLOSURES, AND MECHANICAL, AND ELECTRICAL EQUIPMENT FROM IMPACT BY AUTOMOBILES. INTERIOR BEAMS > 60' MUST BE A MINIMUM OF 30" DEEP PROVIDE A KNOX BOX FOR FIRE DEPARTMENT ACCESS. A KEY FOR EACH SHELL BUILDING AND/ OR TENANT DOOR IS REQUIRED. IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. IF LAWN SPRINKLERS IS PROVIDED, LAWN SPRINKLER SYSTEM MUST BE INSTALLED AND TESTED PRIOR TO CERTIFICATE OF OCCUPANCY. PROVIDE ENVIRONMENTAL SEVICES WITH THE ORIGINAL BACKFLOW TEST REPORT PRIOR TO C.O. All roof and ground -mounted mechanical equipment shall be sreened from view or isolated so as not to be visible from any public right-of-way or residential district within 150 feet of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. Acceptable methods of screening rooftop equipment may include, but are not limited to encasement, parapet walls, or partition screens. A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 ----------------------------------------------- BUILDING DEPT REPRESENTATIVE 4 4 APPLICANT: BUIL'DINGiPERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 07-00002792 Date 10/02/07 Application pin number . . . 422896 ---------------------------------------------------------------------------- Special Notes and Comments CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL PUBLIC SEWER SERVICE IS PROVIDED OR APPROVED ALTERNATE SEWER SYSTEM IS INSTALLED SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO -------------------------------- ---------------- 04 BUILDING DEPT REPRESENTATIVE: A APPLICANT: BUILDING•PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 6 Application Number . . . . . 07-00002792 Date 10/02/07 Application pin number . . . 422896 ---------------------------------------------------------------------------- Special Notes and Comments GLAZING RATIO UP TO 2001 A .40 OR LOWER FACTOR AND ABOVE 200 TO 30% A .35 FACTO OR LOWER SHALL BE MET. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC ) SUBMIT COMPLETE TRUSS DESIGN WITH LAYOUT PLAN RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE ROOM. ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK IF TILE IS INSTALLED AROUND TUBS OR SHOWERS, THEN AN APPROVDED NON-ABSORBANT BACKER MATERIAL THAT COMPLIES WITH 2006 IBC WILL BE REQUIRED, AND SHALL BE INSPECTED PRIOR TO COVER-UP. PROVIDE BACKFLOW DEVICE ON WATER SUPPLY LINE SERVING THE THIRD FLOOR AND HIGHER. ---------------------------------------------- s- *- _ ------------------- BUILDING DEPT REPRESENTAT APPLICANT: BUILDING•PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 7 Application Number 07-00002792 Date 10/02/07 Application pin number . . . 422896 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" 3600.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid ---------- Credited ---------- Due ---------- ----------------- Permit Fee Total 1736.00 1736.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 3600.00 3600.00 .00 .00 Grand Total 5336.00 5336.00 .00 .00 ------------------------- - BUILDING DEPT REPRESENTATIVE ' : ,j 4 APPLICANT: -4, W r1i CITY OF COLLEGE STATION Planning Cr Dndop.m .Snvim ADDRESS/LOCATION: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) i64-3570 (979) 764-3496 FAX WWW:ICSTX.GOV 1 1 /� 5 � l,/1 V- 1" � �✓ C"r v` lJ ,� nl FN1 7 �5 For OK DA E: RCC REG APPLICATION �'' I;Q TEibIP POLE # F �/1 .492, LOT BLOCK SUBDIVISION Buri SEC/PH �— I LP BUSINESS/OWNER NAME: nF Cot1Pnc. S+o, ,on PHONE:-100 . 35-1. `it06 v CONTRACTOR/HOMEOWNER: Dntl?.Fo'i ( lt�i> I l�Pf� I'n� PHONE: l.(};R CONTRACTOR ADDRESS: _'tF*�o -F%mrs�In,, 3010C,i J ELECTRICIAN: 70 ire Rn I ou,,)C-i PLUMBER: -�c� ilr,�nunC e ci HVAC: I n he- lAnni2�;.kocQ GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION I MOVING SHELL ONLY DEMOLITION (Asbestos Survey) y NEW CONSTRUCTION ` SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: nS,l v STRUCTURE USE: moo{ lsake� CnnAnon In i l-k m <z I i eo i (Cost of Labor and Materials) l PUBLIC SEWER SEPTIC/TREATMENT SYSTEM /SIZE I J3164-V-Poo"WATER TAP: * 1 SIZE i ER AP: --2 ) SIZE TEMP POLE I HOMEOWNER ASSOCIATION TEXAS ACCESSIBILITY STAN VALUATION: $ GARAGE TYPE: SINGLE ATTACHED F7 iITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: (TAS) PROJECT REGISTRATION# EABPRJ ro ' TOTAL AREA: 16 46 I HEATED AREA: i a ()aq NUMBER OF BEDROOMS: a-1 NUMBER OF BATHROOMS: 0�1 JPU II INTERIOR WALL TYPE: EXTERIOR WALL TYPE FOUNDATION TYPE ROOF TYPE: DOUBLE E:D TRIPLE DETACHED F-] CARPORT J T E gna►NcED ; ll nn 1T (Sln I ^w, � o PARKLANDEDICATION .FEES DUE SIGNATURE OF APPLICANT: I �— Z 6.za- •a *If proposed work involves new commercial constructs nor fac e provements/renovations to an existing commercial property, building elevations are required. AO�iOAi�i40►♦4A®4�l��o����i4+ 4vAA•►Ola6elilAl9e�9 Official Use Only � O G' L ,/) Comments: [� S NO Plans Examiner i oning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic). Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating