Loading...
HomeMy WebLinkAboutRES2007-02737, 07-2738PREPARED 10/14/08, 12:01:49 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/14/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 1107 PETERSBURG CT SUBDIV: SHENANDOAH PH 13 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER ED FROEHLING BUILDER INC PHONE PARCEL 569500-1336-0060 APPL NUMBER: 07-00002737 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 10/15/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00 10/15/07 AP October 15, 2007 9:59:25 AM kwolfe. Strings On Setbacks O.K. Slab Ground Installed B120 01 10/24/07 RH BLDG, FRAMING -PARTIAL TIME: 17:00 10/24/07 AP October 24, 2007 2:24:02 PM kwolfe. APA framing October 24, 2007 2:26:02 PM kwolfe. B115 01 12/14/07 RH BLDG, FRAMING TIME: 17:00 12/14/07 AE December 13, 2007 3:44:53 PM acarter. 12/14/2007 10:35 AM RH PDA By insulation in anchors at front door, connect exhaust duct to master bath fan, install back windows and tape seal them and all penetrations through TYVEK before foam sealant. Install brace on wall to right of backdoor a per plans. B130 01 1/15/08 RH BLDG, INSULATION TIME: 17:00 1/15/08 DA January 14, 2008 3:58:27 PM kwolfe. O1/15/2008 11:24 AM RH PDA Did not install master bathroom exhaust duct as noted at framing. B130 02 1/18/08 RH BLDG, INSULATION TIME: 17:00 1/18/08 AP January 17, 2008 3:43:21 PM kwolfe. B125 01 10/14/08 BI _ _ BLDG, FINAL TIME: 17:00 LA1p"g� October 14, 2008 11:53:21 AM lsouth.__. ------------------------------------- COMMENTS AND NOTES ------------------ Date: 10/15/2008 Inspection Comments for Final, Permit Year: 7 permit Number: 2737 Address: 1107 PETERSBURG CT Type Inspection Type Code Description status Inspection Result Comments B100 BLDG, FOUNDATION-SL, IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION-SU IC Slab Ground Installed B115 BLDG, FRAMING IC 12/14/2007 10:35 AM RH PDA B115 BLDG, FRAMING IC By insulation install anchors at front door, connect 13115 BLDG, FRAMING IC exhaust duct to master bath fan, install back windows and 13115 BLDG, FRAMING IC tape seal them and all penetrations through TYVEK before 13115 BLDG, FRAMING IC foam sealant. Install brace on wall to right of backdoor a 13115 BLDG, FRAMING IC per plans. B120 BLDG, FRAMING-PARTIP IC October 24, 2007 2:26:02 PM kwolfe. B130 BLDG, INSULATION IC 01/15/2008 11:24 AM RH PDA B130 BLDG, INSULATION IC Did not install master bathroom exhaust duct as noted at B130 BLDG, INSULATION IC framing. Page 1 1sr 04/29/2008 13:20 9797740565 ED FROEHLING BUILDER Ed Froehling, Builder 3887 High Lonesome Road — College Station, Texas 77845 Phone (979) 776-8266 — Fax (979) 774-0565 April 29, 2008 City of College Station 1101 Texas Ave College Station, Texas 77840 Dear Chris Haver, PAGE 06/08 1. would like to request an extension oia the permit for 1107 Petersburg Ct. (permit # 07-00002737). Our houses are built up to a certain point before a buyer is found for the home. We have not found a buyer for this home at the present time. Please contact me with any questions. Sincerely, C TI 10/14/2008 11:02 9797740565 ED FROEHLING BUILDER PAGE 18/19 TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT Pr�O�e� FROENI. ING HOMES pit to be...I#'��Lt . 1107 PETERSBURG CT. 2695 er�entaa® of T rmtic�de � n1ied at ttlis€L rvRe of Tre�ti�0.+E t: Full PartiaLXX— Vertical �t Horizonta Perimeter Beem_k T -rut•a. �.:.. label of _T_a[sta�O��ci� Ge�lart of thisstprttent. 4 LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY) NOLUDINO AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE. TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WmiIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT �bULD DEVELOP AS A RESULT OF THE OWNFR'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED. '� t`�,,^]I hr.yi,f�i��i°fir ���I �°� .Celr,�•�l;•/'s,%.�lP�'IV. Charges for pre -treat: $939.74 NOTES: Annual re-newal: $130.00 32129. PT CA or Timbmetan SPCA rleense A 10/12/2007 921Z9 P7 WF0967754 / 001 City of College Station PAGE 1 REQ. DATE: 09/20/07 09/20/07 8:29:15 LOCATION: 1107 PETERSBURG CT LOC ID: 201754 REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 09/20/07 SCHED COMPLETION: 09/20/07 JOB ORDER RESULT COMMENTS ..: 11:02 9797740565 ���";��yri`.drijti �c.c'' ED FROEHLING BUILDER ACE PEST CONTROL T.P.C.L. # 7120 PT PO BOX 4474 BRYAN, TX 77805 (979) 823-7777 (979) 774-4736 CERTIF'ICAT. , PAGE 19/19 The following property 1107 PETERSBURG CT. ' built by FROEHLING.HOMES State of Texas County of BRAZO the city of COLLEGE STATION Mailing Address SAME Zip code " 7ZS45 was treated for subterranean termites on. ails day OCTOBER 12, 2007 and has met with approval. Cost of initial treatment, $393.74, is payable upon completion of work. The treatment is guaranteed for 12 months from the date of treatment. Tbereafter, this contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection and renewal fee of 1$ 30.. plus tax, for a period of^ 4 years. ( see attached letter ) if at any time during this contract a reinfestation of subterranean termites should occur, the above said property will be treated at no additional cost to the owner. ACE PEST CONTROL does not accept any liability for any subterranean termite damage repair. Failure to pay the annual renewal fee within thirty days after the inspection date shall be construed as a eaucellation of this contract. Any alteration or addition to the foundation of the above described property without proper termite treatment by ACE PEST CONTROL Services shall nullify this contract. Licensed and regulated by Structural Pest Control Board P.O. BOX 1927 Austin, TX 78767-1927 (512) 305-8250 City of College Station 1101 TFXAS r,VENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . . . 10/16/08 569500-1336-0060 1107 PETERSBURG CT COLLEGE STATION TX 77845 SHENANDOAH PH 13 SHENANDOAH #13, BLOCK 36, LOT 6 SINGLE FAMILY RESIDENTIAL ED FROEHLING BUILDER INC ED FROEHLING BUILDERS 979 776-8266 Application number 07-00002737 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type COMBUSTIBLE (UNPROTECTED) Occupancy type RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . I /l c Approved . . . . . . Bui0ing-Official VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING PERMIT CITY OF1 COLIIEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570, FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 07-00002737 Date 9/19/07 Application pin number . . . 782346 Property Address . . . . . . 1107 PETERSBURG CT Property ID: 569500-1336-0060 R #: R301805 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SHENANDOAH PH 13 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 140052 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDER INC ED FROEHLING BUILDERS 3887 HIGH LONESOME 3887 HIGH LONESOME RD COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2122.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 427.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 525832 Permit Fee . . . . 583.00 Plan Check Fee .00 Issue Date . . . . 9/19/07 Valuation . . . . 140052 Expiration Date . . 3/17/08 Qty Unit Charge Per Extension BASE FEE 460.00 41.00 3.0000 THOU BLDG, VAL 100001-500000 123.00 ---------------------------------------------------------------------------- Special Notes and Comments -Narrow Wall Bracing Fully Sheathed with APA Garage Framing and Interior Anchors Bolts and Bracing at Back Door. -------------------------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF' COLIJEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002737 Application pin number . . . 782346 Page 2 Date 9/19/07 Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS . ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES'WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 251-Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES - --------------------------------------------------/�`/•----------- BUILDING DEPT REPRESENTATIVE APPLICANT: -.--'o - 'f BUILDING PERMIT CITY OF'COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00002737 Date 9/19/07 Application pin number . . . 782346 ---------------------------------------------------------------------------- Special Notes and Comments PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL"KNOWLEDGE/EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF ------------------------------------------ ------ --•---'--------- BUILDING DEPT REPRESENTATIVE: ---- APPLICANT:-, — BUILDING PERMIT CITY OF' COLILEGE STATION 1101 TEXAS AVENUE, COLLEG)E STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002737 Application pin number . . . 782346 Page 4 Date 9/19/07 Special Notes and Comments THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 200-o A .40 OR LOWER FACTOR AND ABOVE 200 TO 30% A .35 FACTO OR LOWER SHALL BE MET. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ----------------------------------------------- ---------------------------- -----Fee-summary--------Charged--------Paid----Cred,ed e ,,- --------- BUILDING DEPT REPRESENTATIVE: If. APPLICANT BUILDING PERMIT CITY OF' COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . ----------------- ---------- Permit Fee Total 583.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1333.00 07-00002737 782346 -------------------- 583.00 .00 .00 .00 750.00 .00 1333.00 .00 ----------------------------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: Page 5 Date 9/19/07 .00 .00 .00 .00 -- -/--------- TEMPORARY POLE PERMIT CITY OF'COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00002738 Date 9/19/07 Application pin number . . . 865204 Property Address . . . . . . 1107 PETERSBURG CT Property ID: 569500-1336-0060 R #: R301805 Application type description TEMP POLE Subdivision Name . . . . . . SHENANDOAH PH 13 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ED FROEHLING BUILDER INC ------------------------ ED FROEHLING BUILDERS 3887 HIGH LONESOME 3887 HIGH LONESOME RD COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845 (979) 776-8266 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . AC Permit pin number 525840 Permit Fee 20.00 Issue Date 9/19/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited Due ------------------------------ ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------------------------------------- -- ----- -------------- BUILDING DEPT REPRESE�AT�: APPLICANT: CATS , I I 'v OC REG 1� ' APPLICATION FOR BUILDING PERMIT -- 1101 TEXAS AVENUE APPLICATION # a COLLEGE STATION, TX 77840 CITY ¢8 �ozlF `.rd S? (978} 7643570 (978) 764.306 FAX TEMP POLE d rlaxidll lit oXe�nk£ >ei WWW.C8TX.GOV ADDRESS/LOCATION: � t )I • p �s4� rx CURT LOT �„✓BLACK SUBDIVISION J��`�^� wA� SEWPH / BUSINESSIOWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: treC Lt"43 PHONE: CONTACT PERSON FOR REVIEW COMMENTS: _ PHONE: FAX: -7-7 A -051o5 ELECTRICIAN: 15 A HVAC: _Jot Imat-414T1 w EMAIL: ___ PLUMBER: _ TIE1PtJ65 GOOD CENTS (Residential only): ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTIONSLAB ONLY DUPLEX (LandscapePlans) PREMODELJRENOVATION* EF SWIIMCIAN POOL TIEN DESCRIPTION OF WORK: PROPOSED USE: Sit-I&L9 FAM LV R851MhlG9 HOMEOWNER ASSOCIATIOWARCHITASTUAL OR DESIGN ECT 17E0 SRATREVIEW# EARPRJEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (T ) VALUATION: $ 1'1V 52 •O�`� TOTAL AREA: HEATED AREA: (Cwt oT Labor and Materials) 5fPU6uC SEWER SEPTIC-ITREATMENT SYSTEM ,LII [MeSEWERTAP: WATER TAP: SIZE t ER TAP: P POLE GARAGE TYPE: 3rc� SINGLE ATTACHED d NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: 2 INTERIOR WALL TYPE: EXTERIOR WALL TYPE: BRCIL FOUNDATION TYPE: S� c4 ROOF TYPE'� DOUBLE TRIPLE Q DETACHED F] CARPORT SIGNATURE OF APPLICANT: *If proposed worts Involves new comm rcia an on facade I vementsirenovations to an existing commercial property, building elevations are red. ♦•oo�oo�0000000♦+�♦�+oo+ooeoocliv eoo y oe ♦o�oos0000��•�•o+♦ t �J)PExaminer Zoning Official Fire Marshall /lans /� J,.������ W� l� ern ants: *-cal t4 i /YESIor NO j 1M'rK.l Energy Code:CompllanceInformation % Glazing of exterior walls 13•�/ Insulation R value of exterior walls 3 Insulation R value of ceiling i (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) N /Pe" Glazing SHGC (Solar heat Gain Coefficient) Glazing U-FactorCe • R value.of ductwork A/C SEER Rating .Protection Against Subterranean Termites Chemical Termiticide Treatment (Soil Treatment) ❑ Chemical Terauticide TYeatment (]Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. - a , CITY OF COLLEGE STATION Planning d Development Servitor PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# .7 a% DATE: BUILDING ADDRESS: I. Foundation Requirements- Minimum City Foundation Standards NA/ A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement and Beam Reinforcement F. Protection Method used for Termites. G. Wood foundation details indicated OK II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/Ift A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck MOK E. Header sizes indicated on plans NA/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans CITY OF COLLEGE STATION Planning 6 Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX Q. Tempered Glass required in all hazardous locations Q R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK WK A. Stairway Details K 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements INACCW A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NAT 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required I CITY OF COLLEGE STATION Planning d Development Servitor PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N K B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N K Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block any water course or divert any flow Elevation certificate needed 6YOK "APPROVED PLANS PER IRC SECTION R106.3.1." i CITY OF COLLEGE STATION Planning 6 Development Semica PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLANS E MINER CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX 9-/2-()-7 DATE Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\1212HBck.rck TITLE: 1107 PETERSBURG COURT CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 09/08/07 DATE OF PLANS: JANUARY 22, 2003 PROJECT INFORMATION: SPEC HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC NOTES: SAME PLAN AS 1212HB WITH ADDED BACK PORCH COMPLIANCE: Passes Maximum UA = 726 Your Home UA = 583 19.7% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.37 Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 2122 30.0 0.0 74 Wall 1: Wood Frame, 16" o.c. 430 13.0 0.0 28 Window 1: Metal Frame, Double Pane with Low-E 53 0.650 34 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Front Projection factor: 0.18 Door 1: Solid 38 0.400 15 Wall 2: Wood Frame, 16" o.c. 490 13.0 0.0 35 Window 2: Metal Frame:Double Pane with Low-E 64 0.650 42 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Left Side Projection factor: 0.18 Wall 3: Wood Frame, 16" o.c. 430 13.0 0.0 28 Window 3: Metal Frame:Double Pane with Low-E 75 0.650 49 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Back Projection factor: 0.33 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 135 deg. from North; Comp. orient.: Back Projection factor: 0.81 Wall 4: Wood Frame, 16" o.c. 490 13.0 0.0 36 Window 4: Metal Frame:Double Pane with Low-E 49 0.650 32 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Unheated 192 0.0 200 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 13 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 a ase lb (fo rly MECchecl and to comply with the mandatory requirements listed in the RES checkInsp cklist. a Builder/Designer Date V O .5outhern Plantation Drive 60' R.O.W. - 38' Pavement Vol. 6580, Pg. 214 Back / Curb 5' Sidewalk N 45 26' 36" E - 65.0' 20' P.U.E. 10' P.U.E. - - - - q _j - - - - - � — — — — — — ---- - - - - -- - - -- NN 1mCP 7. ' ! 10.0 B.S.L. r✓ 3` r f.+w-. �'rrF� cx-z�'.lnru�,.y r - r,`✓ e^FP,� r,,.'.r yG 'e rr >r� �3` 1 J"3�' ✓� ref r3�L r ,..,7r, s 7r` Se- ��ftXr1 7arir�`Frrr'r.�F �-Y-.Fr� l r .4r-J^1 ' rr Sty qF to { , r�rl Nt^�� �.c�,�v •rrr� '"��r r r# ia Wit r xr�r rh yyt rrr f - y`d N ENE �^S. f," r -.t p "' � r a,�,��,�r r � r, n r ?n�l}",� ; �1 `'`��. tr Lot 5 Block 36 Lot 7 Block 36 I r �n ,,,, u � e�ersbur N Ff `.. .t of *, 'S y�-,�4 a. r f7,4� .y. fi 3 •. FF gz 4 i 4 � ,� C� � ✓Proposed r � � f, � �� � �! M ��i: �r'�F� f�� 4r"'f LC'r '��i�'�zF � •e��� ''riirl yf Ci rr W. Shen�rJdoah`�Phase��13� -cs$r i'i. ,r'�ar]§ rr,..�yrdtc•• xff�' r r i47- 0 { et'�'vr7r iys'S�• �r �t i A +' '?' rr c„ox� � y. .{� �f 1 0.24' r�q � r r�'�,r✓Pn r ��r � � r. �$� a c �ir�1.i rryrsi '�• ` Co►icrete ado I • Dd9 ew4 1 o� Go I m N I of i o I N 45 26' 36" E - 65.0' N Petersburg Court 50' R.O.W. - 27'Pavement Vol. 6580, Pg. 214 Scale 1 " = 20' ED FROEHLING BUILDER, INC 3887 HIGH LONESOME RD LIVING AREA COLLEGE STATION, TEXAS SHENANDOAH SUBDIVISION 2122 SQFT PHONE 979.776.8266 FAX 979.774.0565 1107 PETERSBURG COURT ALL PLANS SUBJECT TO CHANGE 47'-0" 18'-0" 15'4" "- 13'-8" 2860 860 PORCH o6 OBS MP MED LIN= o . _ _ ,.m, to � in CIO N rrLt�► N 2850 8' CEILING 2 50 2068 00 —` � "" N '•v tO CLG 8'CLG DO DD CABINET \ 14x20 0 r — I N W I B'CLG 1 '-6" ' I " 6'-10'" T-0' z DO N N DO ry N KNEE SPACE MASTER BEDROOM \ } , � i; ' 2868 Go. —� BEDROOM � / in O60 1acLc 2868 DO N DO N W CLG d9 nnnn N c to BE RO Do N 47' BAR ¢ ® � 8'CLG 8'CLG 4' 4'-6' 3'/6" 1 3.1" — 7'-2" 5.04 4,-411 2" o 8:-1 KIT SINK DO ' \ N + a MED (O N /lJ l N DO N 2068 I RSS I wA 2068 22'_8 �4-4 DO 5,_3, Q) -� SHELF � N � 00 N N COUNTER 2868 BEDROOM `\\\</ \� LAUNDRY 1� 0' CLG � n V "fl \ LIVING ROOM \•\ � 7'-4" \ DRYER WASHER \ B' CLG �.� 86 7210 TRANSOM z LL Z >S oce � ON 10 FREEZER STAN C) ' z 01 O w _ I ATTIC ACCESS 3 2S7?' X 54" I L \\ 2870 2870 23' 3068 721 205E5 WINDOW DDOOR I '-3 9" '-" 6 FRZR p FRAMING NOTES: �) FULCY SH l EGV 'O% _ I J� O I Lc)3J ApA�BW_tGMIGAT. MED CABINETS IN EtS,FOR,y/�C IS 14'20' 10'CLG YI - 4.) ATTIC ACCESS 251 X 5/ SIDING ONLY PORCH Ll j NON-GFCI FOR SJ NO BRICK ABOVE NO BRICK POCKET FOR GE POST _ _ _ w SPRINKLER 7. LARGE BRICK POST IKEi212 7J HB - p N 8. CHIMNEY CHASE 3P 30" \ -- -GARAGE— — -� APDO A NARROW WALL BRACT � 16' FOR B' CEILINGS - I \ 16068 � 12'20" 15'_0" 47'-0"