HomeMy WebLinkAboutRES2007-02737, 07-2738PREPARED 10/14/08, 12:01:49 INSPECTION TICKET PAGE 6
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/14/08
------------------------------------------------------------------------------------------------
ADDRESS . : 1107 PETERSBURG CT SUBDIV: SHENANDOAH PH 13
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER ED FROEHLING BUILDER INC PHONE
PARCEL 569500-1336-0060
APPL NUMBER: 07-00002737 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 10/15/07 OC BLDG, FOUNDATION -SLAB TIME: 17:00
10/15/07 AP October 15, 2007 9:59:25 AM kwolfe.
Strings On Setbacks O.K.
Slab Ground Installed
B120 01 10/24/07 RH BLDG, FRAMING -PARTIAL TIME: 17:00
10/24/07 AP October 24, 2007 2:24:02 PM kwolfe.
APA framing
October 24, 2007 2:26:02 PM kwolfe.
B115 01 12/14/07 RH BLDG, FRAMING TIME: 17:00
12/14/07 AE December 13, 2007 3:44:53 PM acarter.
12/14/2007 10:35 AM RH PDA
By insulation in anchors at front door, connect
exhaust duct to master bath fan, install back windows and
tape seal them and all penetrations through TYVEK before
foam sealant. Install brace on wall to right of backdoor a
per plans.
B130 01 1/15/08 RH BLDG, INSULATION TIME: 17:00
1/15/08 DA January 14, 2008 3:58:27 PM kwolfe.
O1/15/2008 11:24 AM RH PDA
Did not install master bathroom exhaust duct as noted at
framing.
B130 02 1/18/08 RH BLDG, INSULATION TIME: 17:00
1/18/08 AP January 17, 2008 3:43:21 PM kwolfe.
B125 01 10/14/08 BI _ _ BLDG, FINAL TIME: 17:00 LA1p"g� October 14, 2008 11:53:21 AM lsouth.__.
------------------------------------- COMMENTS AND NOTES ------------------
Date: 10/15/2008
Inspection Comments for Final,
Permit Year: 7 permit Number: 2737
Address: 1107 PETERSBURG CT
Type
Inspection Type Code
Description
status
Inspection Result Comments
B100
BLDG, FOUNDATION-SL,
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION-SU
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
12/14/2007 10:35 AM RH PDA
B115
BLDG, FRAMING
IC
By insulation install anchors at front door, connect
13115
BLDG, FRAMING
IC
exhaust duct to master bath fan, install back windows and
13115
BLDG, FRAMING
IC
tape seal them and all penetrations through TYVEK before
13115
BLDG, FRAMING
IC
foam sealant. Install brace on wall to right of backdoor a
13115
BLDG, FRAMING
IC
per plans.
B120
BLDG, FRAMING-PARTIP
IC
October 24, 2007 2:26:02 PM kwolfe.
B130
BLDG, INSULATION
IC
01/15/2008 11:24 AM RH PDA
B130
BLDG, INSULATION
IC
Did not install master bathroom exhaust duct as noted at
B130
BLDG, INSULATION
IC
framing.
Page 1
1sr
04/29/2008 13:20 9797740565 ED FROEHLING BUILDER
Ed Froehling, Builder
3887 High Lonesome Road — College Station, Texas 77845
Phone (979) 776-8266 — Fax (979) 774-0565
April 29, 2008
City of College Station
1101 Texas Ave
College Station, Texas 77840
Dear Chris Haver,
PAGE 06/08
1. would like to request an extension oia the permit for 1107 Petersburg Ct. (permit
# 07-00002737).
Our houses are built up to a certain point before a buyer is found for the home.
We have not found a buyer for this home at the present time.
Please contact me with any questions.
Sincerely,
C TI
10/14/2008 11:02 9797740565 ED FROEHLING BUILDER
PAGE 18/19
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
Pr�O�e� FROENI. ING HOMES
pit to be...I#'��Lt . 1107 PETERSBURG CT.
2695
er�entaa® of T rmtic�de � n1ied at ttlis€L
rvRe of Tre�ti�0.+E t: Full PartiaLXX— Vertical �t
Horizonta Perimeter Beem_k
T
-rut•a. �.:..
label of _T_a[sta�O��ci� Ge�lart of thisstprttent.
4 LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY)
NOLUDINO AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE.
TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WmiIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT
�bULD DEVELOP AS A RESULT OF THE OWNFR'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED.
'� t`�,,^]I hr.yi,f�i��i°fir ���I �°� .Celr,�•�l;•/'s,%.�lP�'IV.
Charges for pre -treat: $939.74
NOTES: Annual re-newal: $130.00
32129. PT
CA or Timbmetan SPCA rleense A
10/12/2007
921Z9 P7
WF0967754 / 001 City of College Station
PAGE 1
REQ. DATE: 09/20/07 09/20/07 8:29:15
LOCATION: 1107 PETERSBURG CT LOC ID: 201754
REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 09/20/07 SCHED COMPLETION: 09/20/07
JOB ORDER RESULT COMMENTS
..: 11:02 9797740565
���";��yri`.drijti
�c.c''
ED FROEHLING BUILDER
ACE PEST CONTROL
T.P.C.L. # 7120 PT
PO BOX 4474
BRYAN, TX 77805
(979) 823-7777
(979) 774-4736
CERTIF'ICAT. ,
PAGE 19/19
The following property 1107 PETERSBURG CT. '
built by FROEHLING.HOMES State of Texas
County of BRAZO the city of COLLEGE STATION
Mailing Address SAME Zip code " 7ZS45
was treated for subterranean termites on. ails day OCTOBER 12, 2007 and has met
with approval. Cost of initial treatment, $393.74, is payable upon completion of work.
The treatment is guaranteed for 12 months from the date of treatment. Tbereafter, this
contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection
and renewal fee of 1$ 30.. plus tax, for a period of^ 4 years. ( see attached letter ) if
at any time during this contract a reinfestation of subterranean termites should occur, the
above said property will be treated at no additional cost to the owner. ACE PEST
CONTROL does not accept any liability for any subterranean termite damage repair.
Failure to pay the annual renewal fee within thirty days after the inspection date shall be
construed as a eaucellation of this contract. Any alteration or addition to the foundation
of the above described property without proper termite treatment by ACE PEST
CONTROL Services shall nullify this contract.
Licensed and regulated by
Structural Pest Control Board
P.O. BOX 1927
Austin, TX 78767-1927
(512) 305-8250
City of College Station
1101 TFXAS r,VENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . . .
10/16/08
569500-1336-0060
1107 PETERSBURG CT
COLLEGE STATION TX 77845
SHENANDOAH PH 13
SHENANDOAH #13, BLOCK 36, LOT
6
SINGLE FAMILY RESIDENTIAL
ED FROEHLING BUILDER INC
ED FROEHLING BUILDERS
979 776-8266
Application number 07-00002737 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type COMBUSTIBLE (UNPROTECTED)
Occupancy type RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
I /l c
Approved . . . . . .
Bui0ing-Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
BUILDING PERMIT
CITY OF1 COLIIEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570, FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00002737 Date 9/19/07
Application pin number . . . 782346
Property Address . . . . . . 1107 PETERSBURG CT
Property ID: 569500-1336-0060
R #: R301805
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . SHENANDOAH PH 13
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 140052
Owner Contractor
------------------------ ------------------------
ED FROEHLING BUILDER INC ED FROEHLING BUILDERS
3887 HIGH LONESOME 3887 HIGH LONESOME RD
COLLEGE STATION TX 778459443 COLLEGE STATION TX 77845
(979) 776-8266
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2122.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 427.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . AC
Permit pin number . 525832
Permit Fee . . . . 583.00 Plan Check Fee .00
Issue Date . . . . 9/19/07 Valuation . . . . 140052
Expiration Date . . 3/17/08
Qty Unit Charge Per Extension
BASE FEE 460.00
41.00 3.0000 THOU BLDG, VAL 100001-500000 123.00
----------------------------------------------------------------------------
Special Notes and Comments
-Narrow Wall Bracing Fully Sheathed with APA Garage Framing
and Interior Anchors Bolts and Bracing at Back Door.
--------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF' COLIJEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002737
Application pin number . . . 782346
Page 2
Date 9/19/07
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS .
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES'WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 251-Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
-
--------------------------------------------------/�`/•-----------
BUILDING DEPT REPRESENTATIVE
APPLICANT: -.--'o - 'f
BUILDING PERMIT
CITY OF'COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 07-00002737 Date 9/19/07
Application pin number . . . 782346
----------------------------------------------------------------------------
Special Notes and Comments
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL"KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
------------------------------------------ ------ --•---'---------
BUILDING DEPT REPRESENTATIVE: ----
APPLICANT:-, —
BUILDING PERMIT
CITY OF' COLILEGE STATION
1101 TEXAS AVENUE, COLLEG)E STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002737
Application pin number . . . 782346
Page 4
Date 9/19/07
Special Notes and Comments
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 200-o A .40 OR LOWER FACTOR AND ABOVE 200
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------- ----------------------------
-----Fee-summary--------Charged--------Paid----Cred,ed e
,,- ---------
BUILDING DEPT REPRESENTATIVE: If.
APPLICANT
BUILDING PERMIT
CITY OF' COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
----------------- ----------
Permit Fee Total 583.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1333.00
07-00002737
782346
--------------------
583.00
.00
.00
.00
750.00
.00
1333.00
.00
-----------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
Page 5
Date 9/19/07
.00
.00
.00
.00
-- -/---------
TEMPORARY POLE PERMIT
CITY OF'COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00002738 Date
9/19/07
Application pin number . . .
865204
Property Address . . . . . .
1107 PETERSBURG CT
Property ID:
569500-1336-0060
R #:
R301805
Application type description
TEMP POLE
Subdivision Name . . . . . .
SHENANDOAH PH 13
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
ED FROEHLING BUILDER INC
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME
3887 HIGH LONESOME RD
COLLEGE STATION TX 778459443
COLLEGE STATION TX
77845
(979) 776-8266
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . AC
Permit pin number 525840
Permit Fee 20.00
Issue Date 9/19/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT 45.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited Due
------------------------------
-----------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
---------------------------------------- -- ----- --------------
BUILDING DEPT REPRESE�AT�:
APPLICANT:
CATS , I I 'v OC REG 1�
' APPLICATION FOR BUILDING PERMIT --
1101 TEXAS AVENUE APPLICATION # a
COLLEGE STATION, TX 77840
CITY ¢8 �ozlF `.rd S? (978} 7643570 (978) 764.306 FAX TEMP POLE d
rlaxidll lit oXe�nk£ >ei WWW.C8TX.GOV
ADDRESS/LOCATION:
� t )I • p �s4� rx CURT
LOT �„✓BLACK SUBDIVISION J��`�^� wA� SEWPH /
BUSINESSIOWNER NAME:
PHONE:
CONTRACTOR/HOMEOWNER: treC Lt"43 PHONE:
CONTACT PERSON FOR REVIEW COMMENTS: _ PHONE:
FAX: -7-7 A -051o5
ELECTRICIAN: 15 A
HVAC: _Jot Imat-414T1 w
EMAIL: ___
PLUMBER: _ TIE1PtJ65
GOOD CENTS (Residential only):
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTIONSLAB ONLY
DUPLEX (LandscapePlans) PREMODELJRENOVATION* EF SWIIMCIAN POOL
TIEN
DESCRIPTION OF WORK:
PROPOSED USE: Sit-I&L9 FAM LV R851MhlG9
HOMEOWNER ASSOCIATIOWARCHITASTUAL OR DESIGN ECT 17E0 SRATREVIEW# EARPRJEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (T )
VALUATION: $ 1'1V 52 •O�`� TOTAL AREA: HEATED AREA:
(Cwt oT Labor and Materials)
5fPU6uC SEWER
SEPTIC-ITREATMENT SYSTEM
,LII
[MeSEWERTAP:
WATER TAP:
SIZE
t
ER TAP:
P POLE
GARAGE TYPE:
3rc�
SINGLE
ATTACHED d
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS: 2
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE: BRCIL
FOUNDATION TYPE: S� c4
ROOF TYPE'�
DOUBLE TRIPLE Q
DETACHED F] CARPORT
SIGNATURE OF APPLICANT:
*If proposed worts Involves new comm rcia an on facade I vementsirenovations to an existing
commercial property, building elevations are red.
♦•oo�oo�0000000♦+�♦�+oo+ooeoocliv eoo y oe ♦o�oos0000��•�•o+♦
t
�J)PExaminer Zoning Official Fire Marshall
/lans /� J,.������ W� l� ern ants:
*-cal t4 i /YESIor NO j 1M'rK.l
Energy Code:CompllanceInformation
% Glazing of exterior walls 13•�/
Insulation R value of exterior walls 3
Insulation R value of ceiling i (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic) N /Pe"
Glazing SHGC (Solar heat Gain Coefficient)
Glazing U-FactorCe
•
R value.of ductwork
A/C SEER Rating
.Protection Against Subterranean Termites
Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Terauticide TYeatment (]Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
- a ,
CITY OF COLLEGE STATION
Planning d Development Servitor
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# .7 a%
DATE:
BUILDING ADDRESS:
I. Foundation Requirements- Minimum City Foundation Standards
NA/
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/Ift
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
MOK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
CITY OF COLLEGE STATION
Planning 6 Development Services
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
Q. Tempered Glass required in all hazardous locations
Q
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
WK
A. Stairway Details
K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
INACCW
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NAT
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
I
CITY OF COLLEGE STATION
Planning d Development Servitor
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N K
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N K
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
6YOK
"APPROVED PLANS PER IRC SECTION R106.3.1."
i
CITY OF COLLEGE STATION
Planning 6 Development Semica
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
PLANS E MINER
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
9-/2-()-7
DATE
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\1212HBck.rck
TITLE: 1107 PETERSBURG COURT
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 09/08/07
DATE OF PLANS: JANUARY 22, 2003
PROJECT INFORMATION:
SPEC HOME
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
NOTES:
SAME PLAN AS 1212HB WITH ADDED BACK PORCH
COMPLIANCE: Passes
Maximum UA = 726
Your Home UA = 583
19.7% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.37
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
2122
30.0
0.0
74
Wall 1: Wood Frame, 16" o.c.
430
13.0
0.0
28
Window 1: Metal Frame, Double Pane with Low-E
53
0.650
34
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Front
Projection factor: 0.18
Door 1: Solid
38
0.400
15
Wall 2: Wood Frame, 16" o.c.
490
13.0
0.0
35
Window 2: Metal Frame:Double Pane with Low-E
64
0.650
42
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Projection factor: 0.18
Wall 3: Wood Frame, 16" o.c.
430
13.0
0.0
28
Window 3: Metal Frame:Double Pane with Low-E
75
0.650
49
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 0.33
Door 2: Glass 18 0.580 10
SHGC: 0.78
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 0.81
Wall 4: Wood Frame, 16" o.c. 490 13.0 0.0 36
Window 4: Metal Frame:Double Pane with Low-E 49 0.650 32
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Floor 1: Unheated 192 0.0 200
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 a ase lb (fo rly MECchecl and to comply with the mandatory requirements listed in
the RES checkInsp cklist. a
Builder/Designer Date V O
.5outhern Plantation Drive
60' R.O.W. - 38' Pavement
Vol. 6580, Pg. 214 Back / Curb
5' Sidewalk
N 45 26' 36" E - 65.0' 20' P.U.E.
10' P.U.E.
- - - - q _j - - - - - � — — — — — —
---- - - - - -- - - -- NN
1mCP
7. ' ! 10.0
B.S.L.
r✓ 3` r f.+w-. �'rrF� cx-z�'.lnru�,.y r - r,`✓ e^FP,� r,,.'.r yG
'e rr >r� �3` 1 J"3�' ✓� ref r3�L r ,..,7r, s
7r`
Se- ��ftXr1 7arir�`Frrr'r.�F �-Y-.Fr�
l r .4r-J^1 '
rr Sty qF to { , r�rl
Nt^�� �.c�,�v •rrr� '"��r r r#
ia
Wit
r xr�r rh yyt rrr f - y`d N
ENE �^S. f," r -.t
p "' � r a,�,��,�r r � r, n r ?n�l}",� ; �1 `'`��. tr Lot 5 Block 36
Lot 7 Block 36 I r
�n ,,,, u � e�ersbur
N Ff `.. .t of *, 'S y�-,�4 a. r f7,4� .y. fi 3 •.
FF
gz
4 i 4
� ,� C� � ✓Proposed r � � f, � �� � �!
M ��i: �r'�F� f�� 4r"'f LC'r '��i�'�zF � •e��� ''riirl yf Ci
rr W.
Shen�rJdoah`�Phase��13�
-cs$r i'i. ,r'�ar]§ rr,..�yrdtc•• xff�' r r
i47-
0
{ et'�'vr7r iys'S�• �r �t i A +' '?'
rr c„ox� � y. .{� �f 1 0.24'
r�q � r r�'�,r✓Pn r ��r � � r. �$� a c �ir�1.i rryrsi '�• `
Co►icrete
ado I • Dd9 ew4 1
o� Go I
m N I of
i o I
N 45 26' 36" E - 65.0'
N
Petersburg Court
50' R.O.W. - 27'Pavement
Vol. 6580, Pg. 214
Scale 1 " = 20'
ED FROEHLING BUILDER, INC
3887 HIGH LONESOME RD
LIVING AREA
COLLEGE STATION, TEXAS
SHENANDOAH SUBDIVISION
2122 SQFT
PHONE 979.776.8266
FAX 979.774.0565 1107 PETERSBURG COURT
ALL PLANS
SUBJECT TO CHANGE
47'-0"
18'-0"
15'4" "-
13'-8"
2860
860
PORCH
o6
OBS MP MED
LIN=
o
. _ _ ,.m,
to �
in
CIO
N
rrLt�►
N
2850
8' CEILING
2 50
2068
00
—` � ""
N
'•v
tO CLG
8'CLG
DO DD
CABINET
\ 14x20
0
r
— I
N
W
I
B'CLG
1 '-6"
' I
" 6'-10'"
T-0'
z
DO
N
N
DO
ry
N
KNEE
SPACE
MASTER BEDROOM \
} ,
�
i;
'
2868
Go.
—� BEDROOM
�
/
in
O60
1acLc
2868
DO
N DO
N
W CLG
d9
nnnn
N
c
to
BE RO
Do
N
47'
BAR
¢
®
�
8'CLG
8'CLG
4'
4'-6'
3'/6" 1 3.1"
— 7'-2"
5.04
4,-411
2"
o
8:-1
KIT SINK
DO
'
\
N
+
a
MED
(O
N
/lJ l
N
DO
N
2068
I
RSS
I wA
2068
22'_8
�4-4 DO
5,_3,
Q) -�
SHELF
� N
�
00
N
N
COUNTER
2868
BEDROOM
`\\\</
\�
LAUNDRY
1� 0' CLG
�
n
V
"fl \
LIVING ROOM \•\
�
7'-4"
\
DRYER
WASHER
\
B' CLG
�.�
86
7210 TRANSOM z
LL
Z >S oce
�
ON 10
FREEZER STAN
C)
'
z
01
O w
_
I ATTIC ACCESS
3
2S7?' X 54"
I
L
\\
2870
2870
23'
3068 721 205E5
WINDOW DDOOR
I
'-3
9"
'-"
6
FRZR
p
FRAMING NOTES:
�) FULCY SH l EGV
'O%
_ I
J� O I
Lc)3J
ApA�BW_tGMIGAT.
MED CABINETS IN
EtS,FOR,y/�C
IS 14'20'
10'CLG
YI -
4.) ATTIC ACCESS 251
X 5/
SIDING ONLY
PORCH
Ll
j
NON-GFCI FOR
SJ NO BRICK ABOVE
NO BRICK POCKET FOR
GE
POST
_
_ _
w
SPRINKLER
7. LARGE BRICK POST IKEi212
7J
HB
-
p
N
8. CHIMNEY CHASE 3P
30"
\
--
-GARAGE— —
-�
APDO
A NARROW WALL BRACT
�
16' FOR B' CEILINGS -
I
\
16068
�
12'20" 15'_0"
47'-0"