COVER SHEET
SHEET INI�E�
COVER SHEET
G-1
GENERAL NOTES
G-2
SITE PLAN
C-1
FOUNDATION PLAN
S-1
DIMENSION PLAN
S-2
BRACING PLAN
S-3
FRAMING PLAN
S-4
ROOF FRAMING PLAN
S-5
DECKING LAYOUT
S-6
ELEVATIONS
S-7
FRAMING DETAILS
S-8
ELECTRICAL PLAN
E-1
FLOOR PLAN
A-1
DETAILS
A-2
CABINET LAYOUT
A-3
FLOORING PLAN
A-4
FINISHING NOTES
1
Sprinkler System
2
2" Pvc Blinds
3
White Microhood
4
All Appliances White
5
Full House Gutters
6
Large Covered Rear Porch Option
7
Outdoor Ceiling Fan On Rear Porch
PLAN APPROVAL
APPROVED
INITIALS
DATE
ADMINISTRATOR
/
SUPERINTENDENT
/
CUSTOMER
/
From:STYLECRAFT BUILDERS INC
979 690 0348 10/05/2007 10:10 #116 P.002/007
Renewable 5 Year
Subterranean
Termite Retreatment
t 1 i l�k�.� i` .i . i �: Agreement
(Does not cover any other species of Termites)
"Shielding & Protecting
Homes Against Pests"
This agreement provides for rretreatment only of the infested areas covered under the original treatment areas (See Graph).
JXlee',211
Customer Name Date Billing Name if different
9lGf
Street Address of treated structure
(.,5
City State Zip Code
Home Phone
Work Phone
Type of Treatment Partial Bait ) We -Treat
Treatment for: Prevention Control of Subterranean
Termites
Billing Address if different
City
State Zip Code
Initial Termite Cost $
Additional Renewals Paid
Other
Tax
Cash_Check# Total $ 0
Payment $ —
Balance $ 7^ -V —
Credit Card: '
Type Ezp. Date Card Number
5 Year Subterranean Termite Retreatment Guarantee: RP Lee Termite and Pest Control will retreat the. structure for Subterranean
Termites at no cost to the customer, if an infestation of Subterranean Termites is found, as long as the original treatment is paid in full
and the customer is current on their yearly renewals. This Agreement will expire in one (1) year unless the customer elects to pay
the yearly warranty fee. The guarantee can be renewed for up to five (5) years by paying the yearly warranty fee. RP Lee Termite
and Pest Control may approve additional warranty years after the five (5) years with an additional increase in the yearly warranty fee.
The guarantee does not cover any damages to the structure or contents of the customer. The customer agrees to control all condusive
conditions that may cause reinfestation. If the structure is modified, added on to, altered, or if the soil treatment around the structure
is removed the customer must contact RP Lee Termite and Pest Control and pay for additional treatment in order to keep the guarantee
in effect. If the customer does not pay for additional treatment the retreatment guarantee can be cancelled q o
Renewal Fee: Customer may elect to renew the retreatment guarantee for additional years. Thesenewal fee is $ - moo. plus tax.
The renewal fee is due on or before the annual anniversary date or paid $ ol*' plus tax every third (3) month with inspection.
Maintaining the Guarantee: The customer agrees to correct all conducive conditions, at owner's expense, as they exist or as they
occur in the future in order for the guarantee not to be cancelled Customer will make the structure available for inspections and
treatments as requested by RP Lee Termite and Pest Control.
Reinspection: RP Lee Termite and Pest Control will reinspect the structure at customers request or any other times RP Lee Termite
and Pest Control deems necessary. RP Lee Termite and Pest Control recommends that the customer call and set up an annual inspec-
tion at the time of customers yearly renewal.
nsfe : This agreement maybe transferred to anew owner with the payment of a transfer fee of $ copy of the Wood
Destroying Insect Report from the sell, and approval of RP Lee Termite and Pest Control.
This Subterranean Termite Retreatment Guarantee does not prevent and is not intended to control other forms of Termites
mood Formosan etc.). Wood Boring Beetles Carpenter Ants Carpenter Bees Wood Rot Fungus Decay, or any other
wood destroying insects or organisms.
Arbitration: In the event of any dispute arising out of this agreement or any other services performed or not performed the parties
above agree to participate in mediation through and in accordance with the commercial mediation rules of the American Arbitration
Association. The Arbitrator shall consider the legal defenses raised in the arbitration, and the decision of the arbitrator shall be final,
binding, non -appealable and may be entered and enforced in any court having jurisdiction in accordance with the Federal Arbitration
Act.
Limitation of Liability; Landscaping and grass next to the slab may be damaged during treatment, carpet may need to be pulled
up in certain areas around the home, drill holes may need to be made in floor coverings such as tile or linoleum or in cabinets next
to pipe areas, and holes may need to be cut in walls. Customer agrees not to hold RP Lee Termite and Pest Control liable for these
damages, or treatment techniques, or other damages that may occur during treatment.
Agreement- This Agreement shall be the entire agreement between customer and RP LeeTermite and Pest Control. If any part of
this agreement is found to be invalid it shall not affect the validity of any other part of the Agreement.
We are licensed by the Structural Pest Control Board - 333-Guadalupe Suite I-530
Austin, TX 78701 512-305-8250
RP Lee Termite &rPest Control Cert. Apl.# Cust6mer Signature Date
From:STYLECRAFT BUILDERS INC 979 690 0348 10/05/2007 10:10 #116 P.003/007
SUBTERRANEAN 'TERMITE PRE -CONSTRUCTION TREATMENT DISCLOSURE FOR EACH ESTIMATE
Licensed and regulated under the Texas Structural Pest Control Ac
RP LEE TERMITE & PEST CONTROL
PO Box 9423 • College Station; TX 77842 • (972) 690-8622 - TPCL #11486
CUSTOMER INFORMA ON:
Name: .ST/ �«���L Phone #1: Phone #2:
Address: (�, City: State:. Zip Code:
7/ Location to be Treated: f A46Ie
For all treatments there will be a diagram showing exactly what will be treated prior to the beginning of treatment. Review the pesticide label provided to you at thistime for minimum treatment standard.
Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the law. Review the consumer information sheet for further information. If yd
have any questions, contact the pest control compa ft or the Texas Structural Pest Control Board; P.O. Box 1927, Austin, TX 78767-1927. Telephone number (512) 305-8250.
Before conducting a termite preconstruction treatment, the company will present a complete diagram of the structure including construction details. When construction prevents performance of a fu
treatment, in accordance with a -bid for full treatment, any change to a partial treatment by the company providing the treatment will be permitted ff the owner of the structure or the person in charge o
the construction and the certified applicator for the pest control company sign a statement attesting to the construction conditions. The agreement must be attached to the contract with an amender
diagram showing the exact areas to be treated. Copies must be sent to the owner of the property within seven days of the application. _
Type of treatment proposed: (check all.that apply): ❑ Full Partial tyWood GO Bait ❑ Commercial (Single Family
Total square feet to be trQaled: Total linear feet to be treated: �7 y Approximate measurements of structure(s) to be treated: —
A label of • oAJ1 C Rd t _ mmtticide(s) is attached. The.percentage of the termiticide(s) to be applied at this location is_ ✓� %:
Estimated amount of termitic ide to be aDDlied. oallon(s).
THE SUBTERRANEAN TERMITE PRECONSTRUCTION.TREATMENTBUILDERS GUIDE IS ATTACHED ON BACK (SPCB/D4). THE BOARD APPROVED SUBTERRANEAN TERMITE
PRECONSTRUCTION TREATMENT BUILDERS GUIDE MUST BE PROVIDED TO, AND SIGNED BY THE CONTRACTOR OR PURCHASER OF THE PRECONSTRUCTIONTREATMENT
SERVICE Complete details of warranty (if any) indudingt are period of warranty, renewal options and cost and obligations of the contracting partie,& is attached: tithe warranty does not -
include the entire structure treated, the areas included in the warranty are (specify):
A 6onsu r nfbnmfion sheet is also attached.
.. z'2;1W..:__ .... �o -L =mil .... OP.� h��e 5 aiv if Ap -7-&
Signs ure of or Technician Printed Name Date Signaturt of Custom r Verifying Receipt of This Document Date
ITEM It STVR -_NW olm6 White'Copy-seiviOe Provid.¢r Yellow Co Customer
Copy - Farm Deg
_mW mE ftW by Sa*WA cs m1cam 1-866782£27S, Daft TX 02007
Service Treatment Invoice
r
Date: �(J"��'0�% Appoint. Time: '!� am/pm
RpRte: Map Code:
Frequency: M
BM Q S Y
$tar( Time: _ am/pm . Finish Time: aadpm
Type.of Service: nlit) Regular Follow Up 'One Time Charity
:
Structure: la
Crawl P/B Combo
�"
Pets: Dog(s) Cat(s)
Bird(s) FishC/R°
"Shielding A Protecting
Service ddress /�
Homes Against Pests"
TPCL Mlt486
Cost of Service
an .', ; ':
$
5 9 4 U
Name: % �—7�'f�°`ar�ia4 Billing:
Address: "1 l q
Tax,.
$
Payment by:
, -�Alo%
Total Due
�.c.
$ /69.•
Cash El
City: (', TX' 1�;4/� •
Payment
$ _
Check ❑ #
phone:
Balance
$
Credit Card ❑
PEST PROBLEMS: %` • l.4.efi1 DIRECTIONS/ INSTRUCTIONS:
;EQUIP. METH. LOCATION(S)
WOOD DESTROYING INSECTS
wr/
GENERAL PESTS
FLEAS
PRODUCT
Termidor SC-Fipron11.06%
Termidor.80 W.FipronD .06"/0
Bora•care-Disodlum Octaborate Tetrehydate 50"/0
A'dvance-Balt--Abanectin .Oil.%
InvaderHPH-Baygon 1%
Demon WP-Cyano-Phenoxyphenyl
Dimethycyleycloftopanecarbozylate 1%
Tempo Ultra WP-CyHuthrin .025% (Rest):.
(gen. surface spray, spot, mist, crack & crevice)' '
TalstarEZBffenthrin.2%; -
Maxforce-Hydrametbylon j%.2.15%
Cyklck CS Cyfluthrin .0S% '
Phantom .5%
Tengard-Permethrin .5%
Suspend SC-Deltonetnrin 4.75% (REST)
Nygaard-hletbyletnoxy'10% (REST)
Excite R Pyrethrip .05% .
Fostrac-Bromethalln .01%
Bait Station-Large/Small Glue Boards
QTY TARGET PEST(S)
.PAYMENT DUE
UPON RECEIPT
Subterranean Termites, Ants SizeofTank Posted
Subterranear) Termites. Size of Tank- Posted
fr7iF •Subterraneau/Formosan/Dryrvo6dTeermites, Carpenter Ants, Beetles, Posted
:C. arpentei. Ants
Carpenter Ants, Spiders, Crickets, Millipedes, Beetles, Termites.
Cockroaches,'Mllllpedes, Sowbugs, Flies, Ticks; Mosquitos, Pillbags,
Silverfish, Bees, Ants, Carpenter Ants, Scorpions, Spiders.
Ante (Except-Pharaoti), Cockroaches, Crickets, Earwigs, Millipedes, Flies, Fruit Files, Beetles,
POlbugs Sllverfish, spiders, Gnats, Hornets, Wasps, Yellow Jackets:
Ants, Centipedes, Cockroaches, Crickets, Grasshoppers, Scorpions, Ticks, Silverfish, Spiders.
Pharaoh Ants, Crickets, CarpenterAnts, Lg. Roaches, Variety of Ants.
Spiders, Scorpions,
Pharoh Ants, Variety: of'Ants, Roaches.
$(eas,TicksiAnts, Centipedes, Carpenter Ants, Bees, Wasps, Carpenter Bees, Cockroaches,
Crickets, Flies, Earwigs, Millipedes, Beetles; Pillbugs.
�_. Fleas, Bees, Beetles, Roaches, Crickets,' Lice, Flies, Scorpions, Ticks, Waspa.
IGR-Growth Regulator-Fless, Roaches; Crlckots, Flying Insects, Stored Product Pests.
Fleas.
Mice, Rodents, Rats. -
Mice, Rodents, Rats, Bug Monitors.
Speckoz-Pyrocide .50% Housefiles, Mosquitos, Moths, Fleas, Wasps, Hornets, Ticks, Cockroaches.
Bifen I/r Blfenthrin .06% Spiders, Ants, Roaches, Silverfish, Earwigs, Fleas, Scorpions
PAui ment: A -Compressed Sprayer P-Power Sprayer B-Bait Dispenser BS-Bait Station BT-Bait Trap D-Aerosol Can G-Glue Board H-Hand Duster S-Spreader F-Fogger Other
Locetlons: 1--Kitchen 2-Bath(s) 3-Bedrooms, 4-Dining Room 5-Utility 6-Storage 7-Common Areas 8-Garage 9-Perimeter of Structure 10-Attic 11-Yard 12-(Jnder Home 13-Warehouse.14.Office 15-Exposgd Wood 2' up from Slab Other
Method of reatmentsi CC-Craek & Crevice SS -Sub -Slab Injection VT -Void Treatment BP -Bait Placement BS-Broadcast Spray PB-Perimeter Barrier BV-Brick Venire WT-Wood Treatment
PRECAUTIONS: Do not touch treated areas till dry. Do not tamper with bait stations. Ventilate rooms after treatment. Keep pets away until pesticides have dried.
Licenced by the Structural Pest Control Board - 333 Guadalupe, Suite I-530 • Austin, TX 78701. 512-305-82500
SERVICE TECHNICIAN: ve���a <_ CUSTOMER SIGNATURE: % e►e -�� r''lr DATE: 0" -12``
Ple ca raview_tha rivia nman rmf . +in.. ske nk6va-7A.....f..r......t....
CD
CD
CTI
N
I CZ)
CD
v
CD
CD
*k
CD
O
CD
CD
0
J
(11/26/2007)_Gina Southerland - Re: Calling for CO @ 914 _Eagle. Ave �Page_1
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; Eddie Green; Gina South...
Date: 11/26/2007 11:29 AM
Subject: Re: Calling for CO @ 914 Eagle Ave
This is to notify those at Stylecraft needing to know about the repair of water and. sewer
box repairs.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld 11/26/2007 11:25 am >>>
Water meter box broken.
Sewer buried flagged.
Paul
>>> Kim Wolfe 11/21/2007 8:05 AM >>>
any issues?
BP # 07-2708
Thanks
Kimberly Wolfe, CPS/CAP
City of College Station
Planning & Development Services
(979)764-3570
www.cstx.goy
PREPARED 11/21/07, 7:36:26 INSPECTION TICKET PAGE 12
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/20/07
------------------------------------------------------------------------------------------------
ADDRESS . : 914 EAGLE AVE SUBDIV:
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER PHONE
PARCEL 006507-0408-0380
APPL NUMBER: 07-00002708 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT_ BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 9/19/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
9/19/07 AP September 18, 2007 3:07:15 PM glsouth.
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 10/15/07 OC BLDG, FRAMING TIME: 17:00
10/15/07 AP October 12, 2007 3:06:05 PM acarter.
B130 01 10/16/07 JGM BLDG, INSULATION TIME: 17:00
10/16/07 AP October 16, 2007 11:11:14 AM glsouth.
B145 01 10/19/07 RH BLDG, EXT. SHEATHING FASTENER TIME: 17:00
10/19/07 AP October 18, 2007 3:29:42 PM acarter.
late morning please
B125 01 11/20/07 BI ����"" BLDG, FINAL TIME: 17:00
I
It-3(-C'7 November 20, 2007 4:25:09 PM acarter.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
Date: 11 /21 /2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 2708
Address: 914 EAGLE AVE
Type
Inspection Type Code
Description
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
Ell
ELEC, ROUGH IN
IC
10/09/2007 02:45 PM RH PDA
Ell
ELEC, ROUGH IN
IC
Connect gas bond wire at stub out at meter by framing.
E150
ELEC, FINAL
IC
11/12/2007 03:04 PM RH PDA
E150
ELEC, FINAL
IC
All plugs in garage shall be GFI. Downstairs bathroom GFI
E150
ELEC, FINAL
IC
plug not working. Upstairs middle bedroom breaker is
E150
ELEC, FINAL
IC
tripping.
Page 1
WF0964429 / 001 City of College Station
PAGE 1
REQ. DATE: 09/07/07 09/07/07 16:21:34
LOCATION: 914 EAGLE AVE LOC ID: 203758
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 09/07/07 SCHED COMPLETION: 09/07/07
********************************************************************************
JOB ORDER RESULT CONIIKENTS
BUILDING PERMIT A -C
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00002708 Date 9/07/07
Application pin number . . . 490400
Property Address . . . . . . 914 EAGLE AVE
Property ID: 006507-0408-0380
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 107118
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION TX 77845
(979) 690-1222
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE SIDING
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1625.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE-. PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit pin number .
523787
Permit Fee . . . .
484.00 Plan Check Fee .00
Issue Date . . . .
9/07/07 Valuation . . . . 107118
Expiration Date
3/05/08
Qty Unit Charge
Per Extension
BASE FEE 460.00
8.00 3.0000
THOU BLDG, VAL 100001-500000 24.00
-----------------------------------------------------------------------------
Special Notes and Comments
-Make Sure That 2nd
Floor Operable Wi dows are 24" Above
Finished Floor.
---------------------------=--------------
-
- ----------------------
BUILDING DEPT &ERRESENTAT-T-VE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002708
Application pin number . . . 490400
Page 2
Date 9/07/07
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPA T BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/ ACCE S MA®�V�
BUILDING DEPT F"SENT�TIV�
APPLICANT:
BUILDING PERMIT
' CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 07-00002708 Date 9/07/07
Application pin number . . . 490400
----------------------------------------------------------------------------
Special Notes and Comments
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
------------------------------------------- ---- A)064*4641 ------------
BUILDING DEPT REENTATIVE-
APPLICANT:
BUILDING PERMIT
` CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002708
Application pin number . . . 490400
Page 4
Date 9/07/07
Special Notes and Comments
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 2001 A .40 OR LOWER FACTOR AND ABOVE 200-o
TO 3001 A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC )
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE
ROOM. I
------------------------------------------j ----�-- ----------
BUILDING DEPT REPR WTATIVE:
APPLICANT: \ )IF_)"�>< v -
BUILDING PERMIT
' CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number
07-00002708 Date
9/07/07
Application pin number . . .
490400
----------------------------------------------------------------------------
Special Notes and Comments
ALL PLUMBING, ELECTRICAL, AND
HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS
PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE
IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited Due
------------------------------
-----------------
Permit Fee Total 484.00
484.00 .00
.00
Plan Check Total .00
.00 .00
.00
Other Fee Total 750.00
750.00 .00
.00
Grand Total 1234.00
1234.00 .00
.00
------------------------------------------- -� - - ---- ------------
BUILDING DEPT RE ES NTATPVZ'
APPLICANT:
For Office Lre Only
' V , v 1 C%
APPLICATION FOR BUILDING PERMIT DATE: TRCC REG my
*//4"`
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 APPLICATION #
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX TEMP POLE # 1
Planning & Development Services
WWW.CSTX.GOV
ADDRESS/LOCATION: alai E&3LE Ave
LOT 38// BLOCK 0 -/ SUBDIVISION VO✓VT91LQ VrLU^EJE SEC/PH 4
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTACT PERSON FOR REVIEW COMMENTS: ERIC WIVAGG PHONE: 690-1222 ext. 120
FAX: 690-0348 EMAIL: ewivagg(aD_stylecraft-builders.com
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans) REMODEURENOVATIOW SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: Conventional Framing
PROPOSED USE: Sinale Family Residence
WALL BRACING METHOD: PRESCRIPTIVE ❑ APA PORTAL FRAME W/.CSPS 0 ENGINEERED SZL
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $ ID7 0 as TOTAL AREA: 2;3LA HEATED AREA: 162�
(Cost of La or and Materials)
�X PUBLIC SEWER
NUMBER OF BEDROOMS:
❑ SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS:
�X SEWER TAP:
4"
INTERIOR WALL TYPE:
1�
SIZE
�X WATER TAP:
%11
EXTERIOR WALL TYPE:
SIZE
❑ OTHER TAP:
TEMP POLE SIZE
GARAGE TYPE: SINGLE
ATTACHED
FOUNDATION TYPE
ROOF TYPE:
DOUBLE F—] TRIPLE
DETAC _E4 [�] CARPORT
SIGNATURE OF APPLICANT: \ .&
*If proposed work involves new commercial c
commercial property, building elevations are)
3
2
Sheet Rock
Siding and/or Masonry
Slab on Grade
Composition
EJ
C1/b/07 For Stvlecraft
structio or facade improverriehts/renovations to an existing
luired.
Official Use Only
,4 7-4 - 07
(54vjW Plans Examiner Zoning Official
F100A WWO-Ws Z" ` WO- AF CO-ments:
S NO
��;01'14VAe aAaa I eR r
lF're Marshall
i9iaeeA-9J XZ41.5
Energy Code Compliance Information
% Glazing of exterior walls %
Insulation R value of exterior walls R13 /
Insulation R value of ceiling 1 (flat areas) R30
Insulation R value of ceiling 2 (vaulted areas/no attic) R19 /0"
Glazing SHGC (Solar Heat Gain Coefficient) .35
Glazing U-Factor .53
R value of ductwork R6
A/C SEER Rating 13
Protection Against Subterranean Termites
❑ Chemical Termiticide Treatment (Soil Treatment)
Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College -Station
Building Department prior to issuance of the Certificate of Occupancy.
t
CITY OF COLLEGE STATION
planning d Development Servitor
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# O
r
DATE: _ f w 7
BUILDING ADDRESS: 2 / Ll 4��4 te A
-,/e
I. Foundation Requirements- Minimum City Foundlaton Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement and Beam Reinforcement
F.
Protection Method used for Termites.
G.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing plan or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
CITY OF COLLEGE STATION
Planning 6 Development Snvita
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
Q. Tempered Glass required in all hazardous locations
B/
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
M
DOK
&VOK
A. Stairway Details
N
1.
Maximum riser height 7-3/4 inches
2.
Minimum tread width 10 inches
3.
Stairway risers are uniform 3/8" Max. difference
4.
Stairway width not less than 36 inches
5.
Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1.
Treads a minimum of six 6 inches on narrow edge
2.
Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1.
Riser height less than nine and one-half 9-1/2 inches
2.
Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3.
Stairway width not less than thirty-six inches
4.
Headroom required not less than six ft six 6-6 inches
5.
All treads must be identical
D. Guards/handrail details
1.
Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2.
Handrails are required on stairways located two or more risers above floor/grade
3.
Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4.
Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5.
Guards must be a minimum of thirty-six 36 inches above finished floor
6.
Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
OK
A. Hearth extensions
1.
Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2.
Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry
fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1.
Electrical fixtures & switches indicated
2.
Smoke detector locations indicated as required
CITY OF COLLEGE STATION
Planning d Development Snviru
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
3. GFI circuits indicated where required
Q
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NAM
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
K
"APPROVED PLANS PER IRC SECTION R106.3.1."
N
CITY OF COLLEGE STATION
Planning dDemlopmentSa ices
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
4LZ-
LANS EXAMINER
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
9-707
DATE
Permit #
Permit Date
REScheck Software Version 3.7.3
Compliance Certificate
Project Title: Plan # 1623
Report Date: 09/06/07
Data filename: S:\ACAD\Archived\Old REScheck\1623_914 Eagle.cck
Energy Code: 2000 IECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 11 %
Heating Degree Days: 1788
Construction Site: Owner/Agent:
Permit Date: 9/6/07
Maximum SHGC: 0.40 Your SHGC: 0.40
Ceiling 1: Flat Ceiling or Scissor Truss:
Ceiling 2: Cathedral Ceiling (no attic):
Wall 1: Wood Frame, 16" o.c.:
Window 1: Metal Frame, Double Pane with Low-E:
SHGC: 0.40
Door 1: Solid:
Door 2: Glass:
SHGC: 0.40
Floor 1: Slab -On -Grade: Heated: , Insulation Depth: 0.0'
Air Conditioner 2: Electric Central Air: 12 SEER
Furnace 2: Forced Hot Air: 80 AFUE
Designer/Contractor:
1413 30.0
0.0
49
210 19.0
0.0
11
1923 13.0
0.0
137
199
0.670
133
38
0.500
19
18
0.580
10
164
0.0
171
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in
REScheck Version 3.7.3 and to comply with the m ato require ents I'7n the REScheck Inspection Checklis .
57Y[C42AF f a b7
Builder/Designer Company Name Dat
Project Notes:
Previously saved project information:
Spec
914 Eagle
College Station, Texas
Stylecraft Builders, Inc.
4090 St. Hwy. 6 S.
College Station, Texas 77845
Plan # 1623
Page 1 of 1