Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2007-02340, 07-2341
070 I I I 119.67' EBBTIDE COVE I ENERGY SOUTH HAMPTON SITE PLAN OT 1 SCALE: 1 "=20'-0" Amber Carter - Re: CAlling for CO for 1601 Cranberry Dr Page 11 From: Joe Garcia To: Amber Carter; Benjamin McCarty; Chris Haver; Date: 4/10/2008 11:46:09 am Subject: Re: CAlling for CO for 1601 Cranberry Dr OK FOR CO. JMG >>> Amber Carter 04/09/08 12:22 PM >>> by 07-2340 Any issues? PREPARED 4/10/08, 12:14:46 INSPECTION TICKET PAGE 4 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/10/08 ------------------------ ----------------------------------------------------------------------- ADDRESS . : 1601 CRANBERRY DR SUBDIV: SOUTH HAMPTON PH 2 CONTRACTOR EASTERLING HOMES PHONE (979) 776-9709 OWNER PHONE PARCEL 579020-0203-0010 APPL NUMBER: 07-00002340 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 8/31/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 8/31/07 AP August 30, 2007 8:40:04 AM acarter. no rush on this one. Strings On Setbacks O.K. Slab Ground Installed B115 01 10/24/07 RH BLDG, FRAMING TIME: 17:00 10/24/07 AE October 23, 2007 3:48:57 PM glsouth. 10/24/2007 10:06 AM RH PDA Connect bathroom exhaust ducts. Tape seal above front windows properly. Need to cover small strip of OSB at top front of fireplace. By insulation. B130 01 10/31/07 OC BLDG, INSULATION TIME: 17:00 10/31/07 AP October 30, 2007 1:36:00 PM glsouth. B125 01 4/09/08 BB BLDG, FINAL TIME: 17:00 4/09/08 DA April 9, 2008 8:30.:24 AM glsouth. 04/09/2008 04:59 PM BB PDA Need energy requirements posted in electrical panel. Need insulation certificate posted in attic. B125 02 4/10/08 BI BLDG, FINAL TIME: 17:00 4 REINSEPCTION April 10, 2008 10:32:46 AM dgrace. -------------------------------------- COMMENTS AND NOTES -------------------------------------- T�'1Z'L���ZCk� Date: 4/10/2008 [nspection Comments for Final, Permit Year: 7 'ermit Number: 234C Address: 1601 CRANBERRY DR Type inspection Type Code Description siat�s Inspection Result Comments B100 BLDG, FOUNDATION -SLR IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION-SU IC Slab Ground Installed 6115 BLDG, FRAMING IC 10/24/2007 10:06 AM RH PDA 6115 BLDG, FRAMING IC Connect bathroom exhaust ducts. Tape seal above front 6115 BLDG, FRAMING IC windows properly. Need to cover small strip of OSB at top 6115 BLDG, FRAMING IC front of fireplace. By insulation. B125 BLDG, FINAL IC 04/09/2008 04:59 PM BB PDA B125 BLDG, FINAL IC Need energy requirements posted in electrical panel. Need B125 BLDG, FINAL IC insulation certificate posted in attic. E150 ELEC, FINAL IC April 9, 2008 8:30:43 AM glsouth. P100 PLBG, ROUGH IN IC 08/30/2007 09:44 AM JGM PDA P100 PLBG, ROUGH IN IC test not holding P125 PLBG, FINAL IC ITEST NOT HOLDING Page 1 Date: 4/9/2008 Inspection Comments for Final Permit Year: 7 'ermit Number: 234C Address: 1601 CRANBERRY DR Type Inspection Type Code Description Status Inspection Result Comments B100 BLDG, FOUNDATION -St, IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION-SL, IC Slab Ground Installed 13115 BLDG, FRAMING IC 10/24/2007 10:06 AM RH PDA 13115 BLDG, FRAMING IC Connect bathroom exhaust ducts. Tape seal above front B115 BLDG, FRAMING IC windows properly. Need to cover small strip of OSB at top B115 BLDG, FRAMING IC front of fireplace. By insulation. E150 ELEC, FINAL IC April 9, 2008 8:30:43 AM glsouth. P100 PLBG, ROUGH IN IC 08/30/2007 09:44 AM JGM PDA P100 PLBG, ROUGH IN IC test not holding P125 PLBG, FINAL IC TEST NOT HOLDING Page 1 WF0952675 / 001 City of College etation PAGE 1 REQ. DATE: 08/14/07 08/14/07 9:07:04 LOCATION: 1601 CRANBERRY DR LOC ID: 209038 REQUESTOR: EASTERLING HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 08/14/07 SCHED COMPLETION: 08/14/07 ******************************************************************************** JOB ORDER RESULT COMMENTS City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . . . Application number Description of Work Construction type . Occupancy type . . . . Flood Zone . . . . . . Approved . . . . . . 4/22/08 579020-0203-0010 1601 CRANBERRY DR COLLEGE STATION TX 77845 SOUTH HAMPTON PH 2 SOUTH HAMPTON PH 2, BLOCK 3, L OT 1 PLANNED DEVL DISTRICT EASTERLING HOMES LLC EASTERLING HOMES 979 776-9709 07-00002340 000 000 RESIDENTIAL, 1 UNIT DETACHED.NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX ldirfa Of f ici VOID UNLESS SIGNED BY BUILDING OFFICIAL Apr 22 2008 4:22PM Easterling 979-776-5250 TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT Propody Owner: i=A&TtRLINQ:HOMES Location to be Treated: 1601 CRA BERRY Approximate Measures to be Treated: 3044 Percentage of Termticide(a toL be applied at this location: �a � Type of Treatment:, Full Partial XX VerticalXX HorizontaUPerimeter Beam_XX_ Foundation: SLAB Siding BRICK. Primary Use: RESIDENCE Roof: COMPOSITION IEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS SEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY) !DING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF TTS PEST CONTROL OPERATOR TO RE. TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERYOTE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT COULD. DEVELOP A$ A RESULT OF T RE OWNER'S ACTION OR INACTION TWIT WOULD VOID THE WARRANTY HAS ALSO SEEN ATTACHED. Charges for prq-treat: $428:�29 NOTES: Annual re-newal: $1:300.0 32129 PT 813112007 Ce a ToWndon SPm Bcerme M =129 PT BUILQJZI z PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE;STATION, TX 77840 PHONE: (979)764-3570-, FAX: (979)764-3496 http://bpins*pect.cstx.gov ---------------------------------------------------------------------------- Application Number Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00002340 730120 1601 CRANBERRY DR 579020-0203-0010 Date 8/14/07 RESIDENTIAL, 1 UNIT DETACHED NEW SOUTH HAMPTON PH 2 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 160000 Owner Contractor ------------------------ ------------------------ EASTERLING HOMES P.O. BOX 6436 BRYAN TX 77805 (979) 776-9709 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2417.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 447.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 518977 Permit Fee . . . . 640.00 Plan Check Fee .00 Issue Date . . . . 8/14/07 Valuation . . . . 160000 Expiration Date 2/10/08 Qty Unit Charge Per Extension BASE FEE 460.00 60.00 3.0000 THOU BLDG, VAL 100001-500000 180.00 ---------------------------------------------------------------------------- Special Notes and Comments -Narrow Wall Bracing Fully Sheathed wi Interior Anchors and Bracing to left of Front Door Are ----------------------------------------- BUILDING DEPT REPRESENTATIVE: -- =- ------------------ APPLICANT: BUILDING.PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002340 Application pin number . . . 730120 Page 2 Date 8/14/07 Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 30") WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES -------- -------- ----- ---------------- --- --------------- --- ------ --- --- 4 BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILZING, PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00002340 Date 8/14/07 Application pin number . . . 730120 ---------------------------------------------------------------------------- Special Notes and Comments PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF BUILDING DEPT REPRESENTATIVE: APPLICANT: BUI:�DING.PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002340 Application pin number . . . 730120 Special Notes and Comments Page 4 Date 8/14/07 THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 200 TO 30% A .35 FACTO OR LOWER SHALL BE MET. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES -------------------------------------------- ------ ---- ------------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING , PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 07-00002340 Date 8/14/07 Application pin number . . . 730120 ---------------------------------------------------------------------------- Special Notes and Comments AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid ---------- Credited ---------- Due ---------- Permit Fee Total 640.00 640.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1390.00 1390.00 .00 .00 ---------------------------- - BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #• Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00002341 863338 1601 CRANBERRY DR 579020-0203-0010 Date 8/14/07 TEMP POLE SOUTH HAMPTON PH 2 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ EASTERLING HOMES P.O. BOX 6436 BRYAN TX 77805 (979) 776-9709 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . AC Permit pin number . 518985 Permit Fee . . . . 20.00 Issue Date . . . . 8/14/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------------------------------- ------ --- - -- -_------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX VVM.CI.COLLEGESTATION.TX.US ;4k ADDRESS/LOCATION: Fa Ofte Ux OrW DATE: APPLICATION # r TEMP POLE # [J LOT BLOCK - v SUBDIVISION BUSINESS/OWNER NAME: �54erl.* _QgPHONE: 7`I /Y/%S� CONTRACTOR/HOMEOWNER: PHONE: CONTRACTOR ADDRESS: er 0, qS�o "� . &=i ELECTRICIAN: I T"/ram — � A-.. � La-4) PLUMBER: HVAC: GOOD CENTS (Residenbal only): CLASS OF WORK ACCESSORY/STORAGE ADDITION DEMOLITION (Asbestos Survey) DUPLEX (Landscape Plans Req) DESCRIPTION OF WORK: rcA STRUCTURE USE: LOCATION 9YING NEW CONSTRUGfiION IlREMODEURENOVATION RE -ROOF (Total/Partial) SHELL ONLY. SLAB ONLY SWIMMING POOL HOMEOWNER ASSOCIATION/ARCIiITECTUAL OR DEIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS)/PROJECT REGIST N# EABPR. VALUATION: $ 000.�2 ✓ O R :_3oG2 (Cost of t>a and Mate ) �UBLIC SEWER L F DROOMS: - a SEPTICITREATMENT SYST NUMBER OF BATHROOMS: EWER TAP: ALL TYPE: / SIzE 2 ATER TAP: 3 u I ALL TYPE: SIZE OTHER TAP: FOUNDATION TYPE 'SIZE EMP POLE ROOF TYPE: HEATED AREA: Z za 7- GARAGE TYPE: SINGLE DOUBLE E2"TRIPLE a ATTACHED ©/DETACHED CARPORT a SIGNATURE OF APPLICANT: Official Use OnlyCo,mMents: 7-p7 ES rNO Plans Examiner Zoning Official Aw H Ti c cez CJD &V't �� i .y Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls e o Insulation R value of ceiling ' 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) {Z z., Glazing SHGC Glazing U-Factor . (q / R value of ductwork (o A/C SEER rating 13 Lt Protection Against Subterranean Termites U Chemical Termiticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other *Verification of Application shall be submitted to the City of College Station _Building Department prior to issuance of the Certificate of Occupancy. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# _ a O DATE: _ J BUILDING ADDRESS: 0/ n be AAq b1Z . I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated OK Il. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck fWOK E. Header sizes indicated on plans NA/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, rade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations r h PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements K OK A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location a PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NAPK A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NAJOK Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements NA/ Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow Elevation certificate needed A/ K "APPROVED PLANS PER IRC SECTION R106.3.1." NS EXAMINER DATE