Amber Carter - Re: Calling for CO @ 4205 Whispering Creek Dr Page 1
-... _._
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; ...
Date: 10/16/2007 9:46 am
Subject: Re: Calling for CO @ 4205 Whispering Creek Dr
Contacted JR Torres at 220-2325
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld
NO for CO
Sewer buried flagged.
Water has wrong lid.
Paul
10/ 12/2007 3:34 pm > > >
>>> Kim Wolfe 10/10/2007 12:16 PM >>>
any issues?
BP # 07-2336
Thanks
Kimberly Wolfe, CPS/CAP
City of College Station
Planning & Development Services
(979) 764-3570
www.cstx.00v
PREPARED
10/01/07,
11:58:48
INSPECTION TICKET
PAGE 26
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 10/01/07
ADDRESS
. : 4205 WHISPERING CREEK DR SUBDIV: SPRING CREEK GARDENS
PH 2
CONTRACTOR NEW VISION
CUSTOM
HOMES PHONE (979) 220-2325
OWNER
SPRING
CREEK CS DEVELOPMENT PHONE
PARCEL
58288170203-0040
APPL NUMBER: 07-00002336
RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING
PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 O1
8/13/07
OC
BLDG, FOUNDATION -SLAB TIME: 17:00
f l8/13/07
AP
August 10, 2007 1:09:36 PM glsouth.
MORNING
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
9/04/07
RH
BLDG, FRAMING TIME: 17:00
9/04/07
AE
September 4, 2007 8:04:08 AM kwolfe.
09/04/2007 02:53 PM RH PDA
Brace ridge/ valley over kichen/dining area from
something
other than stiff back on ceiling joist.
B130 01
9/05/07
RH
BLDG, INSULATION TIME: 17:00
9/05/07
DP
September 4, 2607 4:07:27 PM kwolfe.
afternoon
09/05/2007 02:37 PM RH PDA
Not ready.
B330 0:2
9/06/07
OC
BLDG, INSULATION TIME: 17:00
9/06/07
AP
September 5, 2007 3:36:45 PM acarter.
B125 61
;.. 10/q1�07
2�
BLDG, FINAL TIME: 17:00
% 0
49Z
October 1, 2007 11:23:09 AM kwolfe.
------I-------------------------------- COMMENTS AND NOTES--------
------------------------------
P0 5m ETA ?'s e",
Date: 10/8/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 2336
Address: 4205 WHISPERING CREEK DR
Insp.
Inspection Type Code
Description
Status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
09/04/2007 02:53 PM RH PDA
B115
BLDG, FRAMING
IC
Brace ridge/ valley over kichen/dining area from something
B115
BLDG, FRAMING
IC
other than stiff back on ceiling joist.
B130
BLDG, INSULATION
IC
09/05/2007 02:37 PM RH PDA
B130
BLDG, INSULATION
IC
Not ready.
P100
PLBG, ROUGH IN
IC
August 9, 2007 8:51:44 AM acarter.
Page 1
WF0947934 / 001 City of CollQge Station PAGE 1
REQ. DATE: 08/08/07 08/08/07 8:22:55
LOCATION: 4205 WHISPERING CREEK DR LOC ID: 205158
REQUESTOR: NEW VISION CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 08/08/07 SCHED COMPLETION: 08/08/07
********************************************************************************
JOB ORDER RESULT COM ENTS
Sep 25 07 12:24p MACIAS 9797744736 p.4
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
o
NEW VISION CUSTOM HOMES
Location to be Treated: 4205 WHISPERING CREEK
Approximate Measures to be Treated: 1826
Percentage of Termticide(s) to be applied at this location- 0.06%61`4 ra,
Type of Treatment Full Partial XX Vertical xx
HorizontaUPerimeter Beam_XX_
Foundation. SLAB Siding: BRICK
Primary Use: RESIDENCE Roof: COMPOSITION
a star One insecticide has been attached as part of -this locum
A LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION pF ANY►
INCLUDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE-
TREAT FOR TERMITE (NFESTATfONS OR REPASR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDMIONSTHAT
COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED.
Charges for pre -treat:
NOTES: Annual re-newal:
SEE: ATTACHED SKETCH
8UILDERS SUPPLIES SKETCH/ PLAN
$276.64
$120.00
32129 PT 8/912007
Ca or Techlncian SPCIB licenses 32129 PT
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . . .
Application number
Description of Work
Construction type
Occupancy type .
Flood Zone . . . .
Approved . . . . . . .
10/23/07
582881-0203-0040
4205 WHISPERING CREEK DR
COLLEGE STATION TX 77845
SPRING CREEK GARDENS PH 2
SPRING CREEK GARDENS #2, BLOCK
3, LOT 4
PLANNED DEVL DISTRICT
SPRING CREEK CS DEVELOPMENT
NEW VISION CUSTOM HOMES
979 220-2325
07-00002336 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
Bidding 01"ficial
VOID UNLESS SIGNED BY BUILDING OFFICIAL
Az; n'
Whispering Creek Dr,
Site Flan
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATIOt 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00002336 Date 8/07/07
675808
4205 WHISPERING CREEK DR
582881-0203-0040
R304261
RESIDENTIAL, 1 UNIT DETACHED NEW
SPRING CREEK GARDENS PH 2
RESIDENTIAL
PLANNED DEVL DISTRICT
110000
Owner Contractor
SPRING CREEK CS DEVELOPMENT NEW VISION CUSTOM
HOMES
LTD
P.O. BOX 86
4490 CASTLEGATE DR
WELLBORN
TX 77881
COLLEGE STATION
TX 778453388 (979) 220-2325
--- Structure Information
000 000 SINGLE FAMILY
Construction Type
COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info
EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1258.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
427.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit pin number
517672
Permit Fee
490.00 Plan Check Fee
.00
Issue Date . . . .
8/07/07 Valuation . . .
. 110000
Expiration Date . .
2/03/08
Qty Unit Charge
Per
Extension
BASE FEE
460.00
10.00 3.0000
THOU BLDG, VAL 100001-500000
30.00
----------------------------------------------------------------------------
Special Notes and Comments
-Narrow Wall Bracing
Fully Sheathed with 18" Minimum APA
-------------------
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX'77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002336
Application pin number . . . 675808
Page 2
Date 8/07/07
Special Notes and Comments
Garage Framing.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 30") WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25, Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX'77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 07-00002336 Date 8/07/07
Application pin number 675808
----------------------------------------------------------------------------
Special Notes and Comments
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST -HAVE 3' CLEARANCE FROM FORCED AIR
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX'77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002336
Application pin number . . . 675808
Page 4
Date 8/07/07
Special Notes and Comments
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 2001 A .40 OR LOWER FACTOR AND ABOVE 200
TO 30o A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
Other Fees
SEWER TAP 4"
WATER TAP 3/4"
350.00
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
------------------------------------------ - --- ----------------------
BUILDING DEPT REPRESENTAT
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX-77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number . . . . .
07-00002336
Date
8/07/07
Application pin number . . .
675808
Permit Fee Total 490.00
490.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total 1240.00
1240.00
.00
.00
-------------------
BUILDING DE
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AV8
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
Application pin number
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00002337 Date 8/07/07
757861
4205 WHISPERING CREEK DR
582881-0203-0040
R304261
TEMP POLE
SPRING CREEK GARDENS PH 2
RESIDENTIAL
PLANNED DEVL DISTRICT
0
Owner Contractor
SPRING CREEK CS DEVELOPMENT
NEW VISION CUSTOM
HOMES
LTD
P.O. BOX 86
4490 CASTLEGATE DR
WELLBORN
TX 77881
COLLEGE STATION
TX 778453388
(979) 220-2325
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit pin number
. 517680
Permit Fee . . .
. 20.00
Issue Date . . .
. 8/07/07
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
----------------------
BUILDING DEPT REPRESENTATIVA:
APPLICANT:
5
/ <Z---,
X f0
40
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION
Planning d'Dede(979) 764-3570 (979) 764-3496 FAX
. lopmenpSeidice;
WWW.CSTX.GOV
ADDRESS/LOCATION: D- `
LOT !4VBLOCK &' SUBDIVISION AA
BUSINESS/OWNER NAME: /Vf_'. X5'r&AA_
CONTRACTOR/HOMEOWNER:
CONTACT PERSON FOR REVIEW COMMENTS: 7, je. %rr•;s
FAX:
ELECTRICIAN: 1-0
HVAC:
I'll
Office Use Only
DATE: 9 1 1 1TRCC REG
APPLICATION # `
TEMP POLE # '
I
' G' SEC/PH
PHONE: 224-) - ,?3Z5
PHONE: ./r J
PHONE:
EMAIL:i���lC=� =• C�
PLUMBER:
GOOD CENTS (Residential only):
ACCESSORY/STORAGE LOCATION
ADDITION MOVING
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION `
DUPLEX (Landscape Plans) REMODEURENOVATION*
DESCRIPTION OF)
PROPOSED USE:
RE -ROOF
SHELL ONLY
SLAB ONLY
SWIMMING POOL
TENT/CANOPY
C
C51z4&C-ek_
f ,
aWzz&4
0
V, 1LN ko0. / ATTACHED ���DETAC D CARPORT
7
V
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
ACCESSIBILITYTEXAS $ TANDARD (TA= PROJECT REGISTRATION# EABPRJ
VALUATION
W_ TOTAL AREA: HEATED AREA:,1AW
(Cost of L96or and Materials)
121/PUBLIC SEWER NUMBER OF BEDROOMS: 3
SEPTIC/TREATMENT SYSTEM
it /
SEWER TAP: •/
/� IZE, ti J� rl
WATER TAP: �9 -
SIZE
OTHER TAP:
TEW,q
'OLD
SIZE
SINGLE
MATURE OF APPLICANT:
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE � TRIPLE
*If proposed work involves new commercol construction or facade i jr t o
commercial property, building elevation re required.
Official Use Only
Plans Examiner
WN
� WN
;w6lop
it
Energy Code Compliance Information
% Glazing of exterior walls 9
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas) • �� /
,eP r
Insulation R value of ceiling 2 (vaulted areas/no attic) 9
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
/
R value. of ductwork
A/C SEER Rating
1
Protection Against Subterranean Termites
Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NA/gK
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
Nkpro
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
ffOK
"A
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# n a 3 3(
V
DATE:
—0 -7
BUILDING ADDRESS:
tAJ h
I. Foundation Requirements- Minimum City Foundation Standards
NA/
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
^VOK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/OM
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, rade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size,
location indicated on plans
grade &
Q. Tempered Glass required in all hazardous locations
.I
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
OK
A.
Stairway Details
kqA10K
1.
Maximum riser height 7-3/4 inches
2.
Minimum tread width 10 inches
3.
Stairway risers are uniform 3/8" Max. difference
4.
Stairway width not less than 36 inches
5.
Stairway headroom not less that six ft. eight 6-8
B.
Winder details
1.
Treads a minimum of six 6 inches on narrow edge
2.
Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C.
Spiral stairway details
1.
Riser height less than nine and one-half 9-1/2 inches
2.
Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3.
Stairway width not less than thirty-six inches
4.
Headroom required not less than six ft six 6-6 inches
5.
All treads must be identical
D.
Guards/handrail
details
1.
Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2.
Handrails are required on stairways located two or more risers above floor/grade
3.
Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4.
Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5.
Guards must be a minimum of thirty-six 36 inches above finished floor
6.
Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace
Requirements
A.
Hearth
extensions
1.
Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2.
Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward
B.
Masonry
fireplace requires 2" clearance from all combustible materials
C.
Chimneys
must meet IRC Chapter 10 Requirements
V. Electrical
A.
Service
Electrical
Requirements
plan to include:
N
�T
1.
Electrical fixtures & switches indicated
2.
Smoke detector locations indicated as required
3.
GFI circuits indicated where required
4.
Arc fault protection for bedroom circuits
5.
Panel location