Loading...
HomeMy WebLinkAboutADDN2007-023190"7- ol319 7 r.� City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . . . Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved 11/08/07 497900-0027-0240 710 BERRY CREEK COLLEGE STATION TX 77845 PEBBLE CREEK PEBBLE CREEK #6, BLOCK 27, LOT 24 SINGLE FAMILY RESIDENTIAL BOHNE, CHADWICK LEE & REBECCA MARIOTT HOMES 979 696-1787 07-00002319 000 000 RESIDENTIAL, ADDITION COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX — Bui&dirfg Official VOID UNLESS SIGNED BY BUILDING OFFICIAL PREPARED 11/06/07, 11:5.9:46 INSPECTION TICKET PAGE 9 City of ------------------------------------------------------------------------------------------------ College Station INSPECTOR: BUILDING INSPECTOR DATE 11/06/07 ADDRESS . : 710 BERRY CREEK SUBDIV: PEBBLE CREEK CONTRACTOR MARIOTT HOMES PHONE (979) 696-1787 OWNER BOHNE, CHADWICK LEE & REBECCA PHONE PARCEL 497900-0027-0240 APPL NUMBER: 07-00002319 RESIDENTIAL, ADDITION --------=--------------------------------------------------------------------------------------- PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 8/09/07 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 8/10/07 AP August 9, 2007 12:22:53 PM kwolfe. early morning B115 01 9/21/07 JGM BLDG, FRAMING TIME: 17:00 9/21/07 AE September 18, 2007 4:20:26 PM glsouth. 09/21/2007 01:42 PM JGM PDA roof bracing need stiffbacks, brace for valley needs to be on raised beam B130 01 9/25/07 RH BLDG, INSULATION TIME: 17:00 9/25/07 AP September 24, 2007 11:33:17 AM kwolfe. tuesday morning B125 02 11 06/ 7 BI BLDG, FINAL TIME: 17:00 (u November 6, 2007 10:22:38 AM acarter. The addition is in the back, and they left the back door unlocked for you. Thanks! B125 01 11/06/07 RH BLDG, FINAL TIME: 17:00 11/06/07 CA November 6, 2007 8:23:52 AM glsouth.V 11/06/2007 09:51 AM RH PDA Iv1��Y✓ No one home. Left door hanger. -------------------------------------- COMMENTS AND NOTES-------------------------------------- Date: 11 /6/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 2319 Address: 710 BERRY CREEK Type Inspection Type Code Description siat�s Inspection Result Comments B115 BLDG, FRAMING IC 09/21/2007 01:42 PM JGM PDA B115 BLDG, FRAMING IC roof bracing need stiffbacks, brace for valley needs to be B115 BLDG, FRAMING IC on raised beam E110 ELEC, ROUGH IN IC BOND METAL BOXES OUTSIDE. E110 ELEC, ROUGH IN IC SMOKE DETECTOR NEED PROPER CLEARANCE FROM A/C BOX. E110 ELEC, ROUGH IN IC NEED WIRE NUT OR CRIMP ON GROUNDS. P120 PLBG, SEWER LINE IC 08/21/2007 11:21 AM JGM PDA P120 PLBG, SEWER LINE IC not ready P120 PLBG, SEWER LINE IC 08/21/2007 04:12 PM JGM PDA P120 PLBG, SEWER LINE IC yard line Page 1 WF0960272 / 001 City of College Station PAGE 1 REQ. DATE: 08/24/07 08/24/07 12:18:21 LOCATION: 710 BERRY CREEK LOC ID: 132712 REQUESTOR: MARIOTT GROUP ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 08/24/07 SCHED COMPLETION: 08/24/07 ******************************************************************************** JOB ORDER RESULT COMMENTS V] 91"310( BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation 07-00002319 Date 8/06/07 795641 710 BERRY CREEK 497900-0027-0240 R101073 RESIDENTIAL, ADDITION PEBBLE CREEK RESIDENTIAL SINGLE FAMILY RESIDENTIAL 102500 Owner Contractor BOHNE, CHADWICK LEE & REBECCA MARIOTT HOMES CHRIS 209 ROCK PRAIRIE RD 710 BERRY CRK COLLEGE STATION TX 77845 COLLEGE STATION TX 778454431 (979) 696-1787 --- Structure Information 000 000 ADDITION Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . IMPACT/PRORATA FEES PAID NA HEATED AREA 698.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 1.00 NUMBER OF BEDROOMS 1.00 TAZ 419.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit pin number . 517276 Permit Fee . . . . 469.00 Plan Check Fee .00 Issue Date . . . . 8/06/07 Valuation . . . . 102500 Expiration Date . . 2/02/08 Qty Unit Charge Per Extension BASE FEE 460.00 3.00 3.0000 THOU BLDG, VAL 100001-500000 9.00 ---------------------------------------------------------------------------- Special Notes and Comments -Add Smoke detectors inside and outside bedroom. Narrow Wall Bracing Fully Sheathed Addition and Modify Breakfast Windows from 3 to 2 and Interior Anchors and Bracing per plans. ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECT BY AN C-F UL7 P CUIT BUILDING DEPT RFaqZR"'8NNTATTVE : , APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 . FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002319 Application pin number . . . 795641 Page 2 Date 8/06/07 Special Notes and Comments INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 30") WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE NSPE20N PROCESS HAS ----------------------------------------- ------------- BUILDING DEPT REP_R NTATIV� : - APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002319 Application pin number . . . 795641 Page 3 Date 8/06/07 Special Notes and Comments BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 2001 A .40 OR LOWER FACTOR AND ABOVE 200 TO 30% A .35 FACTO OR LOWER SHALL BE MET. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (me hanical -WORK MUST ------------------------------------- - - - --- - --- - �0v----------- BUILDING DEPT REPR��TIVE n APPLICANT: BUILDING PERMIT CITY OF. COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number 07-00002319 Date 8/06/07 Application pin number . . . 795641 --------------------------------- ------ 7------------------------------------- Special Notes and Comments BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. ---------------------------------------------------------------------------- Fee summary Charged- 'Paid Credited Due --------------------------------------------------------- Permit Fee Total 469.00 469.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 469.00 469.00 .00 .00 ------------------- BUILDING DE APPLICANT: APPLICATION FOR BUILDING PERMIT ` 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE. STATION. (979) 764-3570 (979) 764-3496 FAX Planning' �;DcvelgpineniSlniice{'. WWW.CSTX.GOV For Office USe Only DATE: V M` TRCC REG APPLICATION # 4 10 TEMP POLE # ADDRESS/LOCATION: I_1%�j� CLrGI"6� % LOT BLOCK SUBDIVISION /,� hL7` uJC� SEC/PH D BUSINESS/OWNER NAME: C cK� iv e PHONE: � /ice!'>37 CONTRACTOR/HOMEOWNER: AIAj �W /n��S PHONE: X rb_ / 7 / CONTACT PERSON FOR REVIEW COMMENTS: Jay>&kgle PHONE: a,/ V(ZU® FAX: bb b ��f�b EMAIL: /pe/trodt ELECTRICIAN: /y/,P. It c,tipiG PLUMBER: HVAC:/ESE GOOD CENTS (Residential only): K CCESSORY/STORAGE LOCATION RE -ROOF DDITION MOVING SHELL ONLY EMOLITION (Asbestos Survey) NEW CONSTRUCTION ` SLAB ONLY DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: z"n'n s d `firo� PROPOSED USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPFjJ VALUATION: $ Ir���,�fJO TOTAL AREA: ,2d. HEATED AREA: E?�/ (Cost of Labor and Materials) (,I/PUBLIC SEWER NUMBER OF BEDROOMS: ❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: ❑ SEWER TAP: INTERIOR WALL TYPE SIZE 0 WATER TAP: EXTERIOR WALL TYPE SIZE OTHER TAP: FOUNDATION TYPE 1 SIZE ❑ TEMP POLE ROOF TYPE: S -�ti O-7 - GARAGE TYPE: SINGLE F__] DOUBLE F__] TRIPLE a ATTACHED CHED CARPORT c SIGNATURE OF APPLICANT: *If proposed work involves new commercia construc ion or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only Plans�.EXa �nU✓+s�ae g�� Zoning Official 4olGt T 01s daa O Comments: :n �NO Fire Marshall Energy Code Compliance Information % Glazing of exterior walls rt Insulation R value of exterior walls -3 Insulation R value of ceiling 1 (flat areas) a Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) . Y L) Glazing U-Factor R value of ductwork (o A/C SEER Rating Protection Against Subterranean Termites 9 Chemical Termiticide Treatment (Soil Treatment) EeChemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. I` I -4 m m c ul r- O aR�' N_ N J ul -u Z7 0 AO=mZ yrDUl r Mrnr N rn6% p N 70 �o z x PROPERTY LINE: g5.21' - N 47'Iq'26" W — — — — — — — — — 10.0' PUBLIC UTILITY EASEMENT I r- — — NG SETBACK LINE— — I I v I I ° I o) I o I� � - m z - al � N �I N cDi l �o I rl N v Z w ml z Z, I o N i Ivy � i Irn ��•�' t3UILDINC SETB ACK — — LINE — — — _I I PUBLIC UTILITY EASEMENT PROPERT - E: g1.82' _ S 43.5 710 BERRY' CREEK ��A= �� r �� IMAMAn� 69ai SQ. F7 SITE MN-0i-161 �69 sa �r PLAN HOMES, INC. ��,W,L PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: BUILDING ADDRESS: I. Foundation Requirements- Minimum City Foundation Stan rds NA/ A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated V AJOK II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck OK E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK OK A. Stairway Details NAJOK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: N 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N OK B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Ener y Requirements N K A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 oK Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 NAP Does not block any water course or divert any flow Elevation certificate needed OK "APPROVED PLANS PER IRC SECTION R106.3.1." L S MINER 8 - 3 -07 DATE