HomeMy WebLinkAboutRES2007-02303, 07-2304PREPARED 1/14/08, 12:21:35
INSPECTION TICKET PAGE 2
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR DATE 1/14/08
ADDRESS
. : 905 DOVE LANDING AVE SUBDIV: DOVE CROSSING PH 3
CONTRACTOR CLASSIC CENTURY HOMES PHONE (817) 561-4369
OWNER
. .
PHONE
PARCEL
. . 230100-0309-0360
APPL NUMBER: 07-00002303 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
$LDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TAP/SQ
. COMPLETED RESULT
RESULTS/COMMENTS
----------------------------------------------------------------------------------------------
B100 O1
9/20/07 JGM
BLDG, FOUNDATION -SLAB TIME: 17:00
9/20/07 AP
September 20, 2007 8:23:40 AM acarter.
Form Survey Submitted
Slab Ground Installed
B120 01
10/08/07 OC
BLDG, FRAMING -PARTIAL TIME: 17:00
10/08/07 AP
October 8, 2007 8:25:55 AM acarter.
APA FRAMING
B115 01
10/15/07 RH
BLDG, FRAMING TIME: 17:00
=-
10/15/07 AE
October 15, 2007 11:41:32 AM kwolfe.
10/15/2007 02:47 PM RH PDA
Connect exhaust flex. Add support for rafter/joist in
master bedroom by insulation. Tape seams and holes.
B130 01
10/18/07 RH
BLDG, INSULATION TIME: 17:00
10/18/07 DP
October 18, 2007 8:56:38 AM acarter.
10/18/2007 04:20 PM RH PDA
Not ready. Need to tape all seams and holes through green
guard.
B130 02
10/24/07 RH
BLDG, INSULATION TIME: 17:00
10/24/07 AP
October 24, 2007 10:47:35 AM acarter.
B125 01
1/07/08 RH
BLDG, FINAL TIME: 17:00
1/07/08 DP
January 7, 2008 11:06:57 AM kwolfe.
O1/07/2008 03:23 PM RH PDA
Need proper support at back porch. Install hardware and
water heater.
B125 02
1/14/08 BI
BLDG, FINAL TIME: 17:00
IV
January 14, 2008 10:20:44 AM acarter.
--------------------------------------
COMMENTS AND NOTES--------------------------------------
-42R+hYPJTe.J �5/t��Aa.�
li (0-1
•
Date: 1/14/2008
Inspection Comments for Finals
Permit Year: 7 Permit Number: 2303
Address: 905 DOVE LANDING AVE
Insp.
inspection Type Code
Description
p.
Status
Inspection -Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Form Survey Submitted
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
10/15/2007 02:47 PM RH PDA
B115
BLDG, FRAMING
IC
Connect exhaust flex. Add support for rafter/joist in
B115
BLDG, FRAMING
IC
master bedroom by insulation. Tape seams and holes.
B125
BLDG, FINAL
IC
01/07/2008 03:23 PM RH PDA
B125
BLDG, FINAL
IC
Need proper support at back porch. Install hardware and
B125
BLDG, FINAL
IC
water heater.
B130
BLDG, INSULATION
IC
10/18/2007 04:20 PM RH PDA
B130
BLDG, INSULATION
IC
Not ready. Need to tape all seams and holes through green
B130
BLDG, INSULATION
IC
guard.
E110
ELEC, ROUGH IN
IC
10/15/2007 10:25 AM RH PDA
E110
ELEC, ROUGH IN
IC
Smoke detector in front bedroom needs min. 3ft. from fan
E110
ELEC, ROUGH IN
IC
blades. Install all nails in repair strap at top plate by
E110
ELEC, ROUGH IN
IC
framing.
E150
ELEC, FINAL
IC
December 17, 2007 8:32:03 AM glsouth.
M100
MECH, ROUGH IN
IC
10/09/2007 03:33 PM RH PDA
M100
MECH, ROUGH IN
IC
Connect exhaust flex when fans are installed.
P125
PLBG, FINAL
IC
12/17/2007 03:09 PM RH PDA
P125
PLBG, FINAL
IC
All electric.
Page 1
Amber Carter - Re: Calling for C.O. @ 905 Dove Landing Ave Page 1
From: Joe Garcia
To: Amber Carter; Benjamin McCarty; Chris Haver;
Date: 1/8/2008 2:53 pm
Subject: Re: Calling for C.O. @ 905 Dove Landing Ave
ALL OK FOR CO. JMG
>>> Gina Southerland 01/07/08 12:54 PM >>>
BP# 07-2303
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.gov
Jan 08 08 11:01 a Cch - B/cs 979 690 3823 s. p.8
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
Propedy Owner: CLASSIC CENTURY HOMES
Location to be Treated: 905 DOVE LANDING
Approximate Measures to be Treated: 2331
Rementag-0 of Termticide(s) to be applied at this location- 0,06% ks GAL.
Type of Treatment: Full Partial XX yertica��UC
HorizontaUPerimeter Beam—XX—
. - • r. • . 1 •i y l 7 .- - • l_ • l . • • 1_
A LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION ((F ANY)
INCLUDING AREA COVERED. TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBUGATIONS OF THE PEST CONTROL OPERATOR TO RE-
TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT
COULD DEVELOP AS A RESULT OF THE OWNERS ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED.
Charges for pre -treat:
NOTES: Annual re-newal:
SEE ATTACHED SKETCH
BUILDERS SUPPLIES SKETCH/ PLAN
$252.33
$125.00
32129 PT 9/1812007
Ca ar Techinclm SPCB Ikmso 4 32129'PT
F) t SEP-06-2007 THU 04:41 PM
S U R V E Y P L A T
P. 012
This is to certify that I have, this date, made an on the ground survey of the property
located on 905 Dove Landing Avenue in the City of College Station, Texas. described as
follows:
Lot 36. Block 9, of Dove Crossing Subdivision, Phases 3 & 4. an addition to the City of
College Station. Brazos County. Texas, according to the mop or plat therof recorded in
Volume 8130, Page 258. of the Plot Records of Brazos County. Texas.
C,
/ Ur
rb
NOTES:
1. IRF - IRON ROD FOUND
2. IRS - IRON ROD SET
3. Basis of 8earing - Subject Plat
4. C.M. - CONTROLUNG MONUMENT
5. -X- WOOD FENCE
�9
Cb •q,.
Wr
�'� f 4P
'caw
a%L�.o1
aaao tmttrtoae
M dAlndrad 4 to
FWW @M RWW RUr Man br OMW tlaPC. Tdwalr fM aiypet gap.y aawi dlpl r atrb a MOM Apse flmsd Am hm Yq Ap.�, wr dpb
Ckw� tbsnr�r POW A` 40041CCM a WA&d bt b Paid b Zww OL
Nab q• b "" 6"M as 'OLVOW ape UM awo. Nd Aod 6lolwmt � st tiMr M ar � adJbr Mupbrw thwapa � tr daa tam r �
Aw� yapbr IYwb aor and ab Go ad Are Yid Ad b baMMd M dww.pdp w m0�d aao•. Ma ;Ld6 !Yuan! .do ei cr a NOW
11• lfwam b a buk coned ad aavdp of tM Pgwty •► dAoaiwd b w " as i aye r ad d ao nw - wawa. and
1M ery tr ar wmr4 M tpw and eb+Mrbod - MIO nay —a biabd or M PE% a am XWON" d M d and brwwnwib a� s dry,
d Nwowmnab Ewo dli tlw bwndidw d b owpwV n! bod ftm Paywpr it fa OWp hriwbb ad as dli=a *m ew agwt YdwMCI" a, MOM" b a
napan an ad' � 7mm aw W van* anaeadnn� mrdaati or powmam aRw1d v *Am
Rfilllam P. Price '
NlNW wd n r...lwd tone 0- ip► pb. aW
MG
BUENA TIERRA GROUP me � a'--=
sQBVSYnrG•CONsvLTIIQs•]tANAGBIrr400SOUTH INDUSTRIAL. BLVD, SURE 228 (817) 354-1445 S +• - 3'EULE55. TEXAS 76040 (817) 354-1451 (F) PAWN W. MAT
WF0956790 / 001 City of College Station
PAGE 1
REQ. DATE: 08/17/07 08/17/07 15:08:13
LOCATION: 905 DOVE LANDING AVE LOC ID: 209214
REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 08/17/07 SCHED COMPLETION: 08/17/07
********************************************************************************
JOB ORDER RESULT CONIIKENrS
,_BUILDING PERMIT
„ CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAUX,: (979)764-3496
http://bpinspect.dstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00002303 Date 8/17/07
Application pin number . . . 501853
Property Address . . . . . . 905 DOVE LANDING AVE
Property ID: 230100-0309-0360
R #:
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . DOVE CROSSING PH 3
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation 112596
Owner
Contractor
------------------------
------------------------
CLASSIC CENTURY
HOMES
5001 HWY 287 S
ARLINTON TEXAS
ARLINGTON
TX 76017
(817) 561-4369
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info
EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
N/A
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1706.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
AC
Permit pin number .
520023
Permit Fee . . . .
499.00 Plan Check Fee
.00
Issue Date . . . .
8/17/07 Valuation . .
. . 112596
Expiration Date . .
2/13/08
Qty Unit Charge
Per
Extension
BASE FEE
460.00
13.00 3.0000
THOU BLDG, VAL 100001-500000
39.00
----------------------------------------------------------------------------
Special Notes and Comments
-Engineered Bracing
and Foundation
------------------------------------------------
BUILDING DEPT REPRESENTATIVE:
--- 6J_ -
-------
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 1 FAX,: (979) 764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002303
Application pin number . . . 501853
Page 2
Date 8/17/07
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
----------------------------------------------- ---- �----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX,: (979) 764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 07-00002303 Date 8/17/07
Application pin number . . . 501853
----------------------------------------------------------------------------
Special Notes and Comments
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS SITE LOCATED OFF
-------------------------------------------
--- --------------
BUILDING DEPT REPRESENTATIVE:,
APPLICANT:
BUILDING PERMIT
` CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAQ,: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 07-00002303 Date 8/17/07
Application pin number . . . 501853
----------------------------------------------------------------------------
Special Notes and Comments
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20%
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
---------------------------------------------- -----------------------------
Fee summary Charged Paid Cred' ed Due
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Permit Fee Total 499.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1249.00
07-00002303
501853
499.00
.00
750.00
1249.00
------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
Page 5
Date 8/17/07
.00
.00
.00
.00
.00
.00
.00
.00
--j 4-- 1
A ------------
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00002304 Date 8/17/07
Application pin number . . . 616704
Property Address . . . . . . 905 DOVE LANDING AVE
Property ID: 230100-0309-0360
R #.
Application type description TEMP POLE
Subdivision Name . . . . . . DOVE CROSSING PH 3
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
CLASSIC CENTURY HOMES
5001 HWY 287 S
ARLINTON TEXAS
ARLINGTON
TX 76017
(817) 561-4369
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. AC
Permit pin number
. 520031
Permit Fee . . .
. 20.00
Issue Date . . .
. 8/17/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-------------------------------------------- ✓-----Z--- ------------
BUILDING DEPT REPRESENTATIVE: G�
APPLICANT:
Jun 20 07 02:04p Cch - B/cs 979 690 3823 p.2
s
APPLICATION FOR BUILDING PERMIT 4
Gc
GATE• TRC
'—
1101 TEXAS AVENUE
APPLICATION N
CsTroP _ COLLEGE STATION, 'fX 77840
' ��S� O�'� (979) 764-3970 (979) 764-3496 FAX TEMP POLE a
+k�iSSf.! Or1�(e�yyjno'IiS',rivkx
Y4WW.CSTX.GDV
ADDRESWLOCATiON:_ NVey
LOT y3�" BLOCK ��SUBDIVISION ` b oil C . C> SSI Q (-j �EC/PH ✓
BUSINESS/OWNER NAME: CLASSIC _ Q9 �rIK1CS PHONE: I-R60-w -66,5j
CONTRACTOR/HOMEOWNER:
Oj--A55((- Ek) QRY �pHOME: 5 B(09
CONTACT PERSON FOR REVIEW COMMENTS:'--- PHONE:
, ,,A �)
Q��� D �I.�RI 5 PHONE:
FAX:_V%EMAIL:
ELECTRICIAN:
HVAC:
PLUMBER:
GOOD CENTS (Residential only):
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION • SLAB ONLY
DUPLEX (Landscape Plans) REMODEURENOVATION' SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK; / �D�j/��c�7-/d�
PROPOSED USE: / L/c—� �D/[ AV—CrMAJ
HOMEOWNER ASSOCIATION/ARCHI'TECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL• yCs
TEXAS ACCESSIBILITY
S=NA4V)PRO
/ECT REGISTRATION# EA6PRJ_ IIA
VALUATION:$ TOTAL AREA 33I _
HEATED AREA:
(Cost of Labor and Mmarials)
Z PUBLIC SEWER
Q SEPTIGiREA?MENT SYSTEM
SEWER TAP:
�I
bWATER TAP: _5 �t
OTHER TAP:
✓ TEMP POLE S rLE
% GARAGE TYPE:
SINGLE a
N UMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE E] TRIPLE
ATTACHED L�d D-1E;;ACHED n CARPORT
SIGNATURE OF APPLICANT;
aR lCK
-�LQS►'
ftmeb5 m a,J
'If proposed work involves new comma ial n on facade i vementslrandwtions loan existing
commercial property. building elevations are reoulred.
eeeseooeeoeeeeeeeeeseeeeesaeeeeooeaaaee4o9oee•+oee+eeseeeoo•
J� Ofcfa( (Jae Only
94,-07
f p Plans Examiner Zoning Of ial ✓ Fire Marshall
i(s'a44-3e W/ H Commenta: — � rN�'�`i i4 �r�`S �'► aifV.
Ti tcvzi, Acc.erc (5or NO
47M of r vice $*414'..,
Jun 20 07 02:05p Cch - B/cs 979 690 3823 p,3
Energy Code Compliance Information
/o
0 1 Zlo
Glazing of exterior walls
Insulation R value o exterior w - / a f xtan• ills 'J T'('
Insulation R value of ceiling I (flat areas) -,3$ a 6 /
Insulation R value of ceiling 2 (vaulted areas/no attic)�3F17`7
Glazing SHGC (Solar Heat Gain Coefficient) 3
Glazing U-Factor
R value of ductwork
A/C SEER hating 3
Protection Against Subterranean Termites
Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verlflcafion of AppUcation small be submitted to the Cidy of College Station
Building Department prior to issuance of the Cerdfle2te of Occupancy.
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 01 _ 930-5
DATE: 8-1-0r1
1
BUILDING ADDRESS:
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
OK
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
WOK
A. Stairway Details
OK
1.
Maximum riser height 7-3/4 inches
2.
Minimum tread width 10 inches
3.
Stairway risers are uniform 3/8" Max. difference
4.
Stairway width not less than 36 inches
5.
Stairway headroom not less that six ft. eight 6-8
B. Winder details
1.
Treads a minimum of six 6 inches on narrow edge
2.
Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1.
Riser height less than nine and one-half 9-1/2 inches
2.
Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3.
Stairway width not less than thirty-six inches
4.
Headroom required not less than six ft six 6-6 inches
5.
All treads must be identical
D. Guards/handrail details
1.
Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2.
Handrails are required on stairways located two or more risers above floor/grade
3.
Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4.
Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairwa
5.
Guards must be a minimum of thirty-six 36 inches above finished floor
6.
Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N K
A. Hearth extensions
1.
Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2.
Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry
fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NAr
1.
Electrical fixtures & switches indicated
2.
Smoke detector locations indicated as required
3.
GFI circuits indicated where required
4.
Arc fault protection for bedroom circuits
5.
Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Ener y Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block an water course or divert an flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
,j4L_ -4-11
EXAMINER
� - (a __07
DATE
gineering, LLC
401 S. CLAY STREET, ENNIS, TX 75119
July 6, 2007
Classic Century Homes
5001 Hwy. 287 South
Arlington, TX 76017
The following post -tensioned foundation plans are herein authorized for construction at the address and legal
description shown below.
Lot
Blk
Subdivision
Address
Citv
County
State
36
9
Dove Crossing
905 Dove Landing Av.
College Station
Brazos
TX
A site specific soils report was not provided. The foundation has been designed based on the following soils
conditions.
Soils Laboratory
Brazos County USDA Soils Survey
Allowable
Bearing Pressure P.l.
1500 psf 52
The foundation design is in accordance with the applicable provisions of the International Building Code
2000/2003 Edition, the International Residential Code 2000/2003 Edition, the Design and Construction of Post -
Tensioned Slabs -on -Ground, Second Edition, 1996 by the Post -Tensioned Institute, applicable provisions of the
Building Research Advisory Board (BRAB) Publication 33, and accepted engineering practice.
If you have any questions, please call me at 972-878-3647.
PTF0707026
71612007
A.G. (Tony) Medina
Registered Professional Engineer
PHONE: 972.878.ENGR (3647) • FAX: 972.875.1398 • E-MAIL: info@ Woundations.com
10' P.U.E
-
— —
— — — — — — — — —
O
— r—
— — —
cV
N
20' B
I
i
ONE STORY
SINGLE FAMILY
BRICK RESIDENCE
PLAN # 1706
as
a'�a
A
A
�o
�
00
T
40'-0"
7'-6"
7'-7 13/16"
I
I
18' CONC.'
o
I
I
DRIVEWAY
W)
N
-------------------
5' P.U.E
55.15'
OL
905 DOVE LANDING AVENUE
LOT 36, BLOCK 9
DOVE CROSSING SUBDIVISION
COLLEGE STATION, BRAZOS CO.
TX
FLATWORK 858 SQ/FT
GRASS 205 YARDS
i
55.15'
10' P.U.E -
- - - - - - - - - - - -
(V
- - - -
N
ONE STORY
SINGLE FAMILY
BRICK RESIDENCE
PLAN # 1706
O
i
00
40'-0"
7'-7 27/32"
-
18' CONC.
DRIVEWAY
N
5' P.U.E
55.15'
7'-5 31/32"
25' BL
905 DOVE LANDING AVENUE
LOT 36, BLOCK 9
DOVE CROSSING SUBDIVISION
COLLEGE STATION, BRAZOS CO.
TX
FLATWORK 858 SQ/FT
GRASS 205 YARDS
PROVIDE STEEL LINTELS AT ALL
ASONARY OPENINGS AS REQUIRED
on men
i �-- ::MEN ■■■
liffig I I ....... - �.
BRICK QUOINS 16' x 7' OVHD 2. DOUBLE
W I" PROJECTION 3' x 6' DL 1/] MULLED
ROWLOCK
TO SURROUND WINDOWS
PLAN # 1706
lassie
ADDRESS 905 DOVE LANDING
LOT 36 Century
BLK 9 Homes
SUBDIVISION DOVE CROSSING MaMnx N—.o.. neb AgmdaD4
20' 6" 19'6"
4' 3" 3' 0" 6' 0" 3' 0" 4' 3"
3' 0"
en
in
PORCH
---------------------------------- 8' CLG
ao
MSTR SUITE 2' 0" 5' 10" 3' 0"
SLOPE CLG 8' - 10'17 T T
Y .1 V TV I
6' 10" 0"
IPO
FAMILY
8' CLG SLOPE CLG 8'- 10'
Q;) ------------------
4- 5" 3' 0" 96'.
12' 1 2' 5' 5" 42" T
------- --- ---- - --------- — I -----------
----------
BDRM 2
81 CLG BREAKFAST
KITCHEN
40 8' CLG
00
TV
2'
;n 11 4'il' 2'0
7
BDRM 3 -4- ---- -- -----
8'CLG -- :-:
"
--:- a, 4.,
8'CLG
a
_
�
ENTRY DINING':
SLOE CLG 8'- 0'
GARAGE PORCH
8' CLG 8' CLG
10' 2" 2' 4" 4' 4" 2' 2"
10,111, T 2' 4" T I " ELEVATIONS FOR
IT 3" a' a" 2'11 WINDOWS SIZE AND LOCATION
20'6" 14' 0"
F
FOOTAGE
I'LL%
BING
LIVING 1706
1) SHADED WALLS TO 2" x 6" FOR
GARAGE 441
2) ALL HEADER HEIGHTS TO BE 6-
[0" U
qLESS
COPYRIGHT 2000
PORCH 184 FRED BURRIS & CCH
OTHERWISE NOTED
TOTAL 2331
.3) PROVIDE TEMPERED GLASS Wf
ERE
'4EEDED
Q, 0.
PLAN # 1706
lassic
ADDRESS 905 DOVE LANDING AV
LOT 36 Century
BLK -9 Homes
SUBDIVISION 11 DOVE CROSSING
40'e'
20'6" 19' 6"
4-3- 1, 3-0- 6'0" FZ,4 3' 0" 4'3"
)1�2, 3'0" . 5'0—
---------------------------------
-----------------------
PORCH
---------- I -----------------------
8' CLG
MSTR SUITE
2'0" 5' 10" 3'0" 8- 8"
SLOPE CLG 8'- 10-
W
3'0' 610- U13-10" 6 0"
6' V 6' 10"
FAMILY
8' CLG
11 3' 4"
SLOPE CLG 8'- 10'
4'5' 3'0"
12'1.
2'
1-
4
zz
BDRM 2
8' CLG
BREAKFAST
KITCHEN
8' CLG �r
do
f2
ti
4'11'
2 V
BDRM31-4-
2-8-
--- --------
8'CLG
6'7
4'4"
8' CLG
ENTR DINING:
01
SLOPE CLG 8'- 10'
GARAGE
3'V
PORCH
8' CLG
8' CLG
10' 2"
2' 4" L
4' 4" ..2'
2'
4.
ELEVATIONS FOR
1 4"'
3 4 2-11
E[:;SOE:I,'
W
VS SIZE AND LOCATION
20-6"
14' 0"
FOOTAGE
LIVING 1706
1) SHADED WALLS TO 2" x 6" FOR
)LUN BING
GARAGE 441COPYRIGHff 2000
2) ALL HEADER HEIGHTS TO BE 6'.0"
U 14LESS
PORCH 184 FRED BURRIS & CCH
OTHERWISE NOTED
TOTAL 2331
3) PROVIDE TEMPERED GLASS Wl-
ERE ',TEEDED
40'0"
PLAN # 1706
lassic
ADDRESS 905 DOVE LANDING AV
LOT 36 Century
BLK 9 Homes
SUBDIVISION 11 DOVE CROSSING ::] I
GABLE
NOTE:1) Foundation anchor bolts at
60" o.c. as per 2000 IRC
sec. R403.1.6
2) All framing and structural
design to meet 90 m.p.h.
wind criteria as per sec.
R301.2.1 and table R301.
2000 IRC code.
3) All lower sole plate to be
Pressure treated as per
sec. R323. All fasteners
ROOF AS SELECTED
RIGHT ELEVATION
LEFT ELEVATIO
AIL
...........
to be hot dipped galv. steel,
stainless steel, silicon bronze
or coper only as per sec. R323.3
4) Provide hand rails on all stairs/steps
with a minimum of 2 risers as per
sec. R315. (min. stair tread 10":
max. riser 7 3/4" sec. R314.2)
5) Masonry veneer anchorage of
24" horizontal and 18" vertical as
per sec. R703.7.4.1 and weep holes
at a maximum of 33" o.c. as per
sec. R703.7.6.
REAR ELEVATION
PLAN# 1706
lassic
ADDRESS 905 DOVE LANDING
LOT 36 Century
ll
BLK 9 {_. om
SUBDIVISION DOVE CROSSII�TGsx�.a�.��m..a.
In
Electrical
ceiling an
fluorescent fixture
light
outlet
outlet gfi
s
smoke detector
o
spot light
$
switch
to
switch 3 way
sa s�s��s
vanity bar light
®
vent fan w light
------------------------------- -
MSTR SUITE
SLOPE CLG 8' - 10'
BLOCK & WIRE
FOR FAN ONLY
8' CLG I I
C
BDRM 2 \O
8' CLG
Y
BDRM 3 /
8' CLG /
GARAGE
8' CLG
COPYRIGHT 2000
FRED BURRIS & CCH
PORCH;
8' CLG
se /
v x FAMILY
OSLOPE CLG 8' - 10'
-- - 7 ----
BREAWAST
8' CLG
ENTRY
DjNING
- _ - SLOPE CLG 8' - 10'
PORCH
8' CLG
NOTE: 1) Lighting on stair to conect from switch
@ top to light mounted on wall
@ middle of stairs to switch
@ bottom of stairs per sec R303.4
2) Smoke detectors will be hard wired
in serie w/ battery backup power as
per sec. R317
3) Provide 110 outlet & light near HVAC
unit for service with switch.
PLAN #
1706 ELECTRICAL PLAN
lassie
Century
II `
ll oeS
ADDRESS
LOT
BLK
SUBDIVISION
mdtrM xoM. o.,,.,:rry M w<e&
In-SHEArI11NG
AR BA„lEx
.1
MICAL M1OOR SYSiFIk
sn 0 13.1.c
11I BAR msuunUN
W'TAG SIIaFLWI
n'GMUM BOARD
TRUSS SPA GA. TIBCKMI
MBEDETEIONNEDBYctanotA
I..MlcoW-3N
ix+eonoM IMTEA
I
BAITotWIATIONFURZ OFFLW1
WM m—anCAULKIKo —
LLLTALBMTLES l2K+TUr I"no,
1' All SIACB
IMSHMTIIIND
ALL 9AMIE1 BRIcK(wKSFSTUUxInK51DE
h+sTU05916•,c DF ROD, low
111 BATT ndUMTIUN ,0.TEI VENT EVFAY r1DB,I«
-sHEETRocK AT aDRDAII
METALB,1« 0
:'A SrAa
N SHMTHa+G
M BALLIEI
NISTUndt I6•.c
11 BATr INSULAno,,
I?SITES K=
�G BUROM IUIE TRMTEU
VI' PLYWOOD SWE:ATHING
CAu "H' CUPS
MIN. 2"X6" RAFTERS o 24- o—
BATT INSULATION
CONTINUOUS AIR VENT BAFFLES
•24" O.C.
END AT RIDGE TO BE INSTALLED
SO THAT AIR FLOW 15 NOT
RESTRICTED
WOOD FASCIA
J ALL SLAB dAIENSIUHSTm«Nts5F5
al . ✓1 Ra1Nro,CIAIKYTroBEUkltiRMmw Inr
U+GmFFA
sMOUES
cnKTmIp1USABIYENTBAFT gN'0.0
I— AT IIDGE • TD BE DtSTALLFD 50 THAT
Ait FL09'6 NDTAETi,IrIFD
NR:.T4 Mr1k99QM'O.0
I sFUpp SNMmMG
H CIumrS
FASCIA
SORITWIEpUAL1.Y 5PAEFD VENTS J [LQ
QI60.0 p74]1/l'Y�✓_—.➢ryltll—
�`rNlB,IC1t
nEq
A PAcE
In'SII ,uBG
M BAAB.
m sTlrm g m-
l11BAIT RBN
Trr1rAL ix+av« ExrEual wALr:
IrrsxEEr,a«
oclt
7rAITBnIm
NETAL611-Tits
1-MRA«
V.^ SHMTHM
An BARRDR
.+SNOB@ 16.0.r
III) BAIT IKSIA.A M
I75HELTRo«
x+aT gso.rMAx
J A •��1• ALLd1ABa0nrbNN5ni1LW.T,q E5.
'•e � •,eHLGRLtyFNrroeEucTFssa¢TreT
J ENawEEa
TOP VIEW
CHIMNEY CAP
ROOF PITC
2X4 BAND 15
SOFFIT MATERIAL
TYPICAL BRICK EXTERIOR WALL
FACE BRICK
I' AIR SPACE
I/Y SHEATHING
2'x4' STUDS a 16" o.e.
BATT INSULATION CITY OF LOCKHART
1/2' S14EETROCK TYPICAL ROOF OVERHANG DETAIL
TYPICAL WALL DETAILS
2X4 FR)"
MEMBER
SIDE VIEW
NOTE:
1) Foundation anchor bolts at
60" o.c. as per 2000 IRC
sec. R403.1.6
2) All framing and structural
design to meet 90 m.p.h.
wind criteria as per Sec.
R301.2.1 and table R301.2(4)
20031RC code.
3) All Iowa sole plate to be
Pressure treated as per
sec. R323. All fasteners
to be hot dipped galv. steel,
stainless steel, silicon bronze
or coper only as per sec. R323.3
4) Provide hand rails on all stairs/steps
with a minimum of 2 risers as per
sec. R315. (min. Stair tread 10":
max. riser 7 3/4" sec. R314.2)
5) Masonry veneer anchorage of
24' horizontal and 18" vertical as sex
per sec. R703.7.4.1 and weep holes N
at a maximum of 33" O.C. as per HANDRAIL I IN'Mm.
sec. R703.7.6. TO 2 5w MAX SI2 .
.........................
m
0 IN. TREA
q,34 GU nAz
+
U PR
0o z
co �
STAIR DETAIL IRC 2003
D
LUE 21411 0" MIN�1011 MIN.
CHIMNEY
CAP Z
2X4 BAND
O
I I
2X4 FRAMING
MEMBER W
I ^ I
I I�i I
OSB
I W I ■ rNS�C
SIDING Century
� I
HoineS
t �oI Making Nome ON•nen�h � AJJorJabfe
I
Area Calculator:
Window
Name .
Assembly Type
Comments/
IMImulled
Immulled
MM
07/05/07 14:26:02
Window Area Total: 195.00
1/1
Area Calculator:
IMM
Assembly Type
=MIMIMBEMM
Comments/
Description
IM
��■�■��i��
;mom
Door Area Total: 55.56
1/1
SIMPSON LSTA21 OR CS20 (ATTACH -
TO FRAMING ON OPPOSITE SIDES OF
SHEATHING) TYPICAL BOTH SIDES
OF OPENING.
24" MIN
LEA
HEADER
SPAN
6'
(BETW
EN 6'
TO 181)
:
.
o
24" MIN
3" GRID PATTERN 8d
COMMON NAILS TO
HEADER
TOP PLATE TO
HEADER - 2 ROWS OF
16d SINKERS, 311O.C.
3" O.C. NAILING IN ALL
FRAMING -STUDS,
BLOCKS, TOP PLATE,
AND BEHIND THE
STHD10 HOLDDOWN
5/8" TITAN ANCHOR BOLT MIN.
EMBED. DEPTH - 4" TYP.
;a c.
Lp.o...gg.< Q. � ..�4a. :ep a.: Ogg �. ..4 •
• p a
1800 LB HOLDOWN
ONE-STORY STRUCTURES CAN USE
SIMPSON HTT16, PHD2, HDU2, OR
STHD10 HOLDOWNS.
1- - 2-41"M IN.-
FRONT ELEVATION
5'-W MIN.
RIGHT ELEVATION
REAR ELEVATION
TOEd
�I �Ir1XWLETAWNTO
,,BOTTOM PLATE AND
tINTERVENING STUDS. TYP.
LTYP.-0° LESS THAN 25LESS THAN 22-W L
��r
LEFT ELEVATION
5'-0• MIN.
TYP.
2'-6'
TYR
LESS THAN 25-0• I, LESS THAN t r-°
4
i0
VS0LOL0dM9
LEFT
REAR
FRONT
R's
8 m
•Z• '•.
Os
LL
Lu
Vy' Q
'�•'•'. :�: .•• �J U)2w
sot =1 W D 2
r�
rn
W2 Z ~
.- cn
Q^=��� cocrQ�
CL >o V °D � wC'30
J > Z NN
J=OO r0❑N
F-wZ❑ ❑z
W �z Z �wm
U=Zw Z 0)oz
DUo-jL gS❑0
L)Fn �moa
Q C/) H rf 0
RIGHT g z
0
m V U p w 0
O U
= 1"' O
U)
O
O
O
a
m
ui
0
O
U
m
0
m
m
z
�
o
¢
II
�
y
W
o
z
o
N
�
a
3
W
,c...
QCD
N N V
C
W
W
J jS
LL
Q
Q
Q W
m7
TOP OF
GRADE
BRICKLEDGE WHEN
APPLICABLE
i
CHAIR
tD
CUSHION
\
SAND. TYP.
'
TOP OF
POST -TENSION STRANDS
GRADE -
WHEN INDICATED
ON PLAN, TYPICAL
DRAPE BEAM STRAND
WHEN INDICATED
ON PLAN, TYPICAL
#3 SUPPORT STAKE
DETAIL "A"
BRICKLEDGE WHEN
APPLICABLE
3 —CHAIR
— SLAB. STRANDS
WHERE APPLICABLE
—BEAM STRAND
WHERE
APPLICABLE
SUPPORT STAKE
DETAIL "B"
., .�-.1. CHAIR
TOP OF
GRADE -I SLAB STRANDS
WHERE APPLICABLE
DRAPE BEAM STRAND
H WHEN INDICATED
ON PLAN, TYPICAL
DETAIL "C"
•� Y
M�
CUSHION
SAND, TYP.
TOP OF
POST -TENSION STRANDS
GRADE
WHEN INDICATED
' ON PLAN, TYPICAL
1
STIRRUPS
WHEN SPECIFIED
1" 3- #4 BARS
TOP & BOTTOM.
DETAIL I'D"
C
TOP OF
GRADE
SAND. TYP.
POST -TENSION STRANDS
WHEN INDICATED
Q
u
p >
,I '
ON PLAN, TYPICAL.
r= a
O O
2- 45 BARS
o O
� Q
—DRAPE BEAM STRAND
O
WHEN INDICATED
ON PLAN, TYPICAL
'
#3 SUPPORT STAKES
VAPOR
RETARDE
TYPICAL
DETAIL "Al
SLAB STRANDS
WHERE APPLICABLE
.p 2- #5 BARS
BEAM STRAND
WHERE
APPLICABLE
'I #3 SUPPORT STAKE
DETAIL "B1"
BRICKLEDGE WHEN
APPLICABLE
SLAB STRANDS
,
WHERE APPLICABLE
1
2- #5 BARS
iD 7
DRAPE BEAM
STRAND D
TOP OF
WHEN INDICATED
GRADE
ON PLAN, TYPICAL
DETAIL "Cl
'\ --CHAIR
3a SLAB STRANDS
p \ WHERE APPLICABLE
`STIRRUPS
WHEN SPECIFIED
3- #4 BARS
TOP & BOTTOM.
DETAIL "H"
SLAB STRAND
WHERE APPLICABLE
•�.
ill
cr
.'`�
=
#4 BARS
@ 12'O.C.
I
R /I
SEE PLAN FOR
EACH WAY
DETAIL "E"
BRICKLEDGE WHEN
APPLICABLE /
1-#4 BACKUP BAR
�� ••• CHAIR
e• SLAB STRANDS
i WHERE APPLICABLE
O.C.E.W.
DRAPE BEAM
STRAND
WHEN INDICATED
ON PLAN. TYPICAL
BRICKLEDGE WHE.1
APPLICABLE �11.CK`Ul.
/
D ETAI L "G"
BRICKLEDGE WHEN
c�
m
CUSHION
SAND. TYP.
TOP OF
oel'+
,i -
POST -TENSION STRANDS
GRADE
-
", ...
- WHEN INDICATED
ON PLAN, TYPICAL
{
BEAM STRAND
;
,—DRAPE
/ WHEN INDICATED
y�
ON PLAN, TYPICAL
O
UNDISTURBED
SOIL GRADE
4
2- #4 BARS VERTICALLY
SPACED @ 12' O.C. AS
N
REQUIRED PER BEAM
N
DEPTH
NOTE: IT IS IMPORTANT TO USE THIS DETAIL )
44 VERTICAL
WHEN THERE IS A 4' OR LESS SLOPE IN THE
SUPPORTS @ 48'
FOUNDATION FOOT PRINT AREA TO INSURE
THAT SETTLEMENT DOES NOT OCCUR, THE
O C
BOTTOM OF THE PERIMETER BEAM MUST
SOIL A MIN OF 12'�
STANDARD
DEEPEN
L PENETRATE UNDISTURBED
'-� SLAB STRANDS C1
WHERE APPLICABLE
#4 BARS @ 12
O.C.E.W.
DRAPE BEAM
STRAND
WHEN INDICATED
ON PLAN, TYPICAL
NOTE: DETAIL T'
CAN BE
DETAIL "F„ SUBSTITUTED
[FOR DETAIL TV.
SLAB STRANDS
WHERE APPLICABLE
#4 BARS @ 12
-
O.C.E.W.
n. I
NV+
DRAPE BEAM
oa:�:^�_• STRAND
WHEN INDICATED
O
H OA ON PLAN, TYPICAL
DETAIL I'M"
BEAM DETAIL
STRANDS
CHAIR
cTnnlnApn -
BAR
WHEN APPLICABLE
1- #4 BACKUP BAR
114 BARS @ 12' O.C.E.W.
SLAB STRAND
aal::
CHAIR
..q. SLAB STRAND
3'-0' MAX " W . BEAM STRAND
L AS SPECIFIED
— 1- #4 FOR L.= 14' OR LESS
2-#4 FOR L=15'TO 25'
3- #4 FOR L = 26' TO 36'
DETAIL "F1"
S' STRAND AS
SHOWN ON PLAN
1, 2 x D TYPICAL
SHOWN ON PLAN
L WHEN (2)'BS' STRANDS ARE
#3 STAKES AS REQUIRED
SPECIFIED IN THE BEAM,
TO MAINTAIN A 3'
TIE'BS' STRANDS TOGETHER
CLEARANCE FROM THE
AND INSTALL SIDE BY SIDE
BOTTOM OF THE BEAM
AS A SINGLE 'BS' STRAND.
54' MAX. SPACING
INSTALL ANCHORS SIDE BY SIDE
SEE'2-BS' DETAIL
BEAM STRAND "BS" DETAIL.
1Z• # 3 REBAR WITH 2-0'
BENT @ 45' TYP. @
ALL CORNERS
6 , "2-BS" DETAIL
6' 6' ��� S' STRAND
ANCHOR
N �.
'BS' STRAND
ANCHOR
SLAB STRANDS
FORM BOARD
:r —o:
CHAIR
2 /
U
0
TIE WIRE -
CHAIR
LESS THAN 54'
CHAIR LAYOUT
SHEATHING CUT BACK BEHIND ANCHOR
(CARE SHOULD BETAKEN TO
ENSURE SHEATHING DOES NOT
PROTRUDE INTO THE ANCHOR)
FORM - "`^"'
EXCAVATION
TENDON INSTALLATION
AT STRESSING -END
POCKET
16' (12' MIN.) FORMER
CUT PL4,S1c
BEAM HERE
EXCAVATION WOOD
` FORM
COMPLETED
STRESSING -END INSTALLATION
FIXED -END PLASTIC
ANCHOR SHEATHING
3. STRAND
10'-1r
STRIP
SHEATHING
20d NAIL
(MIN.)
FIXED -END (DEAD-END)
LWOOD FORM INSTALLATION
TOP VIEW
STANDARD DETAILS
G Cn A P.CGl /- / f 1.11 —
+1
0
N
w
D_
U)
9ZOLOLOdld
NOTES: h o
1. TO PREVENT SETTLEMENT DUE TO SOIL CONSOU woo: •.•`�/ Z kI Z
ALL EXTERIOR FOUNDATION BEAMS MUST BE FOUNDED A .•' : ; �•.�O�J, ° °C °'
MINIMUM OF 12 INCHES INTO UNDISTURBED SOIL. WHEN 0 j z
FOUNDATION SITE CONTAIINS FILL (MAX. 3'-0'5, THE DEEPEN IL ; :) .4 a a
BEAM DETAIL SHOULD BE USED IN THESE FILLED AREAS.- 00. �Q ; �% aup, ' 3 w
FOR SITES WHERE FILL IS GREATER THAN V-0", PLEASE ila : • ; • �y a a
CONTACT AGTM ENGINEERING LLC TO INCORPORATE ~A.
INTO THE DESIGN. �••'••: : •'• e N M w
2, 3000 PSI, CONCRETE SLAB. �1*_•; W ❑ 6
3. 4" OF CUSHION SAND UNDER CONCRETE SLAB IS � o Q
RECOMMENDED.
4. PROVIDE A 6 MIL POLYETHYLENE MOISTURE RETARDER
BENEATH SLAB AREA. ZO
5. ALL STRANDS 1/2" DIA. - 270 K N
6. THIS FOUNDATION DESIGN IS CONSIDERED INVALID (n w
UNLESS ACCOMPANIED BY A LETTER FROM AGTM uj co Z
ENGINEERING LLC AUTHORIZING ITS USE ON A SPECIFIC Q M !P }
LOT & BLOCK, OR ADDRESS. O � F-
7. PLANS CAN BE REVERSED ON LOT AT BUILDERS Z = ^ U? 0 Z
DISCRETION. OO () o o
8. PLANS ARE FOR STRAND AND BEAM PLACEMENT ONLY. O = N LLI > - vU�
SET FORMS, DROPS, HANDICAP RAMPS, ETC., BYLL O f O Z O
ARCHITECTUAL FLOOR PLAN OR AS SPECIFIED BY 1` cm Z 0 O ►�
OWNER/GENERAL CONTRACTOR, Z Z O m W Cr
9. AT CONTRACTORS OPTION, LIVE END AND DEAD END O L u F- Z Z > > m
REVERSAL IS PERMITTED. V= 0 Ir ZLI) O Z
10. AT CONTRACTORS OPTION, BRICK LEDGE MAY BE U) Z Lu rn o O
In
INCLUDED OR OMITTED AT EXTERIOR DOOR OPENINGS. Z p Q U a -iCy) ~Q
11. DRAINAGE, DRAINAGE, DRAINAGE. THE FINAL GRADE Z M Cl)
AROUND THE FOUNDATION SHALL BE 8" BELOW THE TOP OF
THE FOUNDATION AND SLOPE AWAY FROM THE
O F- W
FOUNDATION A MINIMUM OF 3" IN 5'-0". (n U U OJ
O J
0
12. VIBRATE CONCRETE @ ALL CABLE LOCATIONS 0- O U
ESPECIALLY AT CORNERS WHERE SEVERAL CABLES ARE 0
ANCHORED, MAXIMUM CONCRETE DENSITY IS REQUIRED
TO INSURE THAT A "BLOW-OUT," DOES NOT OCCUR DURING t-u r
CABLE STRESSING. = T u- N
13. THE FOLLOWING SYMBOL INDICATES DROP IN a cn O
FOUNDATION. THE AMOUNT OF DROP AND EXACT 0 r-
LOCATION IS TO BE DETERMINED BY PLAN OR AS 1`
DIRECTED BY OWNER/CONTRACTOR. 0
LL
FOUNDATION: ate.
1. THICKNESS T= 4" Lj,j
2. BEAM WIDTH W= 10" O
3. BEAM DEPTH D= 3311 U
4. AREA = 2328 SQ. FT. ° m
5. EST. CONCRETE = 93 YRDS, 4 g O
6. SOILS REPORT:
CME TESTING AND ENGINEERING, INC. m z F-
1806 WELSH AVENUE, SUITE C
COLLEGE STATION, TEXAS 77840 4 E
❑ m ❑ cc I
PROJECT NO. 26116
DATED: OCTOBER 2, 2006 J W E
0
0—a)REQUIRED.=SEE-DETAILS $ C Q
Zen
N CO co m
.� L j
CAUTION: IN THE EVENT THATACABLE C
PASSES THROUGH A PLUMBING OPENING, ECAUTION: VIBRATE ALL CABLE LIVE C
MOVE CABLE TO EDGE OF OPENING. AND DEAD ENDS TO ENSURE MAX. 'R W LU u-
J .
CABLE SPACING CAN BE ADJUSTED, BUi IN DENSITY CONCRETE ESPECIALLY
NO EVENT CAN CABLE SPACING BE AREAS WHERE MULTIPLESTRANDS UJ
GREATER THAN 5'-W O.C. COME TOGETHER