HomeMy WebLinkAboutADDN2007-02292■' 1
f
0
BUILDING PERMIT
CITY OF COLLEGE -STATION
1101 TEXAS AVENUE, COLLEGE gt)T TION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspOc',t.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
ACKLAM, SHAWN N
1 FOREST DR
COLLEGE STATION
07-00002292 Date 8/02/07
077616
1 FOREST DR
513500-0201-0010
R37998
RESIDENTIAL, ADDITION
POST OAK FOREST ##2
RESIDENTIAL
PLANNED DEVL DISTRICT
20000
Contractor
LAFOLLETTE CONSTRUCTION,
1723 BALL CIR
TX 778402321 COLLEGE STATION TX
--- Structure Information 000 000
Construction Type . . . . .
Occupancy Type . . . . . .
Other struct info . . . . .
INC
77845
(979) 690-7531
ADDITION
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
IMPACT/PRORATA FEES PAID NA
HEATED AREA 740.00
NUMBER OF BATHROOMS 1.00
NUMBER OF BEDROOMS 1.00
TAZ 218.00
----------------------------------------------------------------------------
Permit . . ... . . BUILDING PERMIT
Additional desc . . GS
Permit pin number . 516799
Permit Fee . . . . 110.00 Plan Check Fee .00
Issue Date . . . . 8/02/07 Valuation . . . . 20000
Expiration Date . . 1/29/08
Qty Unit Charge Per Extension
BASE FEE 15.00
19.00 5.0000 THOU BLDG, VAL 1001-50000 95.00
----------------------------------------------------------------------------
Special Notes and Comments
-Add smoke detector inside and outside bedroom.
-Make sure stair construction complies with codes.
-7' ceiling min. requirements are met and ok'd with popups.
-Perimeter walls and ceiling already existed and were
already sheetrocked.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
----- - -�---------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002292
Application pin number . . . 077616
Page 2
Date 8/02/07
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 30") WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20%
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND.LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 110.00 110.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 110.00 110.00 .00 .00
---------------------- -----� --- ------------
BUILDING DEPT REPRESENTATIVE:
----
APPLICANT:
t
APPLICATION FOR BUILDING PERMIT
V4 *1 1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CmrOFCOLLEGE.$TATIQN (979) 764-3570 (979) 764-3496 FAX
Planning :�: pev(ppnirriiSt(yjce'
WWW.CSTX.GOV
F Oft Use Only
DATE: R C REG
APPLICATION:( t
TEMP POLE #
ADDRESS/LOCATION: _* ( F—ptes — . y-e, (f_ S J )C
LOT BLOCK
BUSINESS/OWNER NAME
_ SUBDIVISION
Lae- C,06j--
SEC/PH
PHONE: A112-1351
CONTRACTOR/HOMEOWNER: PHONE:
CONTACT PERSON FOR REVIEW COMMENTS: A
PHONE: 4 1 Z_ 1391
FAX:'' ii�171� ~ O�G Z EMAIL:
ELECTRICIAN: PLUMBER:
HVAC: o ems¢-•r GOOD CENTS (Residential only):
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION " SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION' SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE:�''5� -� U
HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 2-__ 01 &_s3 TOTAL AREA: HEATED AREA: -740
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP:
WATER TAP:
OTHER TAP:
TEMP POLE
GARAGE TYPE
SIZE
SIZE
SIZE
SINGLE
E7
ATTACHED
a
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE: �&
ROOF TYPE: 6D AJ.1 _
DOUBLE F__1 TRIPLE El
DETACHED F__1 CARPORT
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial con ucf nor facade improvements/renovations to an existing
commercial property, building elevations are r uired.
Official Use Only
Plans Examiner Zoning Official / Fire Marshall
- P�i�� �o
+ C ments: P�� f.�„��
i or NO
!7 f Cly. /k;.v /Ltd C,/f Pop V 0 f
Energy Code Compliance Information
% Glazing of exterior walls l) A
Insulation R value of exterior walls 13
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic) AI%-
Glazing SHGC (Solar Heat Gain Coefficient) `{ o
Glazing U-Factor • G �5—
R value of ductwork C ws r
A/C SEER Rating Ex, - s f s
Protection Against Subterranean Termites
�A
❑ Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
4160-