HomeMy WebLinkAboutRES2007-02291, 07-2293p'I •Ztgl
From: Joe Garcia
To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Kim W...
Date: 4/1/2008 9:35 AM
Subject: Re: Calling for C.O. @ 915 Dove Landing Ave.
THIS ONE IS OK FOR CO. JMG
>>> Gina Southerland 03/31/08 12:59 PM >>>
BP# 07-2291
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.csbc.gov
915 DOVE LANDING AVENUE
LOT 31, BLOCK 9
DOVE CROSSING SUBDIVISION
COLLEGE STATION, BRAZOS CO.
7
0
0
55.15'
10' P.U.E
— — —
— — — — — — — — — — —
—
iV
N
20' BL
r—
I
— — — — — — — — — —
I
ONE STORY
SINGLE FAMILY
BRICK RESIDENCE
PLAN # 1706
�
-
A
�n
O
�n
�0
60
�o
7'-6"
40'-011
I
I
I
I
L -
-
- - -
18' CONC.
O
DRIVEWAY
N
5' P.U.E
55.15'
0
0
7'-7 13/16"
25' BL
915 DOVE LANDING AVENUE
LOT 31, BLOCK 9
DOVE CROSSING SUBDIVISION
COLLEGE STATION, BRAZOS CO.
TX
FLATWORK 858 SQ/FT
GRASS 205 YARDS
PREPARED
3/31/08,
8:09:00
INSPECTION TICKET PAGE 2
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR DATE 3/28/08
ADDRESS
. : 915 DOVE LANDING
AVE SUBDIV: DOVE CROSSING PH 3
CONTRACTOR CLASSIC
CENTURY HOMES PHONE (817) 561-4369
OWNER .
.
PHONE
PARCEL .
. 230100-0309-0310
APPL NUMBER: 07-00002291
RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
10/02/07
JGM
BLDG, FOUNDATION -SLAB TIME: 17:00
10/02/07
AP
October 2, 2007 8:52:43 AM glsouth.
Form Surrey Submitted
Slab Ground Installed
Bi-, 0 01
--10/09/07
RH
BLDG, FRAMING -PARTIAL TIME: 17:00
10/09/07
AP
October 9, 2007 12:01:28 PM glsouth.
APA FRAMING
B115 01
11/05/07
RH
BLDG, FRAMING TIME: 17:00
11/05/07
AE
November 2, 2007 11:06:07 AM kwolfe.
11/05/2007 03:09 PM RH PDA
By insulation install joist hangers for rafters at bay
window in master. Tape seal all penetrations through green
guard.
B130 01
11/26/07
RH
BLDG, INSULATION TIME: 17:00
•
11/26/07
DP
November 26, 2007 8:59:27 AM glsouth.
11/26/2007 03:33 PM RH PDA
Not ready.
B130 02
11/27/07
RH
BLDG, INSULATION TIME: 17:00
11/27/07
AP
November 27, 2007 10:28:08 AM glsouth.
B125 01
3/ 8/08
BQ�
BLDG, FINAL TIME: 17:00
3 i10V
j' p O(-
March 28, 2008 2:29:57 PM glsouth.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
C r, T10✓�
,r nVA
Date: 3/31 /2008
[nspection Comments for Final,
Permit Year: 7 permit Number: 2291
Address: 915 DOVE LANDING AVE
Type
Inspection Type Code
Description
Status
Inspection Result Comments
B100
BLDG, FOUNDATION-SV
IC
Form Survey Submitted
B100
BLDG, FOUNDATION-SIJ
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
11/05/2007 03:09 PM RH PDA
B115
BLDG, FRAMING
IC
By insulation install joist hangers for rafters at bay
B115
BLDG, FRAMING
IC
window in master. Tape seal all penetrations through green
B115
BLDG, FRAMING
IC
guard.
B130
BLDG, INSULATION
IC
11/26/2007 03:33 PM RH PDA
B130
BLDG, INSULATION
IC
Not ready.
P125
PLBG, FINAL
IC
January 22, 2008 4:48:49 PM kwolfe.
Page 1
Jan 08 08 10:59a Cch - B/cs 979 690 3823 p.3 1
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
• .M•r • •- :.•
CLASSIC CENTURY HOMES
915 DOVE LANDING
Fj 1T . _ I - •
2331
Percentage of Termticide,,(S.) to be applied at this IoCation: 0.06%178 GAL.
Type of Treatment: Full Partial XX_ Vertical XX
Horizontal/Perimeter Beam XX_
- F -_
-- '' — •N.N'• •L
A LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY)
INCLUDING AREA COVERED, TIME PERIOD OF Vh&RRANTY. RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE-
TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED HY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD. AND THE CONDITIONS THAT
COULD DEVELOP AS A RESULT OF THE OWNER'S ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED.
Charges for pre -treat:
SEE ATTACHED SKETCH
BUILDERS SUPPLIES SKETCH/ PLAN
$252.41
NOTES: Annual re-newal: $125.00
32129 PT
Ca or Techincian SPCS ficame 0
9/28/2007
32129 PT
SEP-06-2007 THU 04:43 PM
S U R V E Y R L A T '
P. 017
0� ,'
This is to certify that I have, this date. made an on the ground survey of the property
located on 915 Dove Landing Avenue in the City of College Station, Texas, described as
follows:
Lot 31, Block 9, of Dove Crossing Subdivision. Phases 3 do 4, an addition to the City of
College Station, Brazos County, Texas, according to the map or plat therof recorded in
Volume 8130, Page 258, of the Plat Records of Brazos County, Texas.
o^Cb
OA,Cb 0
A� cob
1�W PALL
VOL (
Me
7.Y
b,�•
70 4
•
7.9 �.
%VL am PO. me �
NOTES
1. IRF — IRON ROD FOUND
2. IRS — IRON ROD SET
3. Beefs of Bearing — Sub Plot
4. C.M. = CONTROLLING MONUMENT
5. —X— WOOD FENCE
2&4
Wr
i
I.Ls.tr1
RWD ttallsrM
Oaw gr iM�A Nw aug t .Wl.a W r are%boubd Tams. 0 mjed I M 11 D.w N,e r .Mira ski+ cewew
now nw� Wn Newt MM (100 r r nook. bw m.
tr to rr r, �a1d� ddt, m Morilbd mod Motet m,w NY nod SAwma do. ad MW not tM rwrb ad/w drodr eM go be w" ewu a. , - w raw
d6 d D".w GIVOW 0001 owl m0 M OW wq 010 MWO ► v be Mnmsd b amw-amb or ad" oamw 7m Rood aftmNt dd nod soft IMM
fio dot Mrwa r • 6v* aorn,ot mo 0tiatolo npoow�pOwf Q 1w wopwb m AOrmbO br m m tln P - 'mom =a 0o ee and a ew,et� "hove m, od
n•6Rlkeo tld lr d �sn4 liN ia� and dY�s d dd oimwb !iy teirid tti do Ion va M% b . ad !" d NiMw Tot l�O�w�A a� m deq
moon id0 002L llr�o ool4=9 of �NA►w�dba�Yoasfpa1�-I 4NN t N� and er 41a�o0 eom 0n ma�ot MANrdlon m YiOo�MO to a,
4d_ CPO zs.
TOMP. Price
rr OWW nowh" tmd 9r40W ML Me
&NG
BUENA TIERRA GROUP � 1D.
i;TtIMG : °'-d`7
SURY • CvriBTJ 7= • �Ct�r 00/24W
400 SOUTH INDUSTRIAL BLVD.. SURE 228 (817) 354-1445 sum V - W
EULESS. TEXAS 78040 (817) 354-1451 (F) o wa
WF0956793 / 001 City of Co1"lege"Station
0
PAGE 1
REQ. DATE: 08/17/07 08/17/07 15:09:33
LOCATION: 915 DOVE LANDING AVE LOC ID: 209224
REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 08/17/07 SCHED COMPLETION: 08/17/07
********************************************************************************
JOB ORDER RESULT COMMENTS
BUILDING PERMIT
;,,,,.• ''CITY OFt-COLI-SEGE *STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-357'0 FAX: (979)764-3496
http://bpinspect.cstx.gov
---------------------------------------------------------------------- - - - - - -
Application Number . . . . . 07-00002291 Date 8/17/07
Application pin number . . . 834459
Property Address . . . . . . 915 DOVE LANDING AVE
Property ID: 230100-0309-0310
R #•
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . DOVE CROSSING PH 3
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 112596
Owner
Contractor
------------------------
------------------------
CLASSIC CENTURY
HOMES
5001 HWY 287 S
ARLINTON TEXAS
ARLINGTON
TX 76017
(817) 561-4369
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX-
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
N/A
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1706.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit pin number .
519926
Permit Fee . . . .
499.00 Plan Check Fee
.00
Issue Date . . . .
8/17/07 Valuation . .
. . 112596
Expiration Date . .
2/13/08
Qty Unit Charge
Per
Extension
BASE FEE
460.00
13.00 3.0000
THOU BLDG, VAL 100001-500000
39.00
----------------------------------------------------------------------------
Special Notes and Comments
-Engineered Slab and
Wind Bracing
----------------------------------------------------------------------------
BUILDING DEPT REPRESENTATIVE: /
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002291
Application pin number . . . 834459
Page 2
Date 8/17/07
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 30") WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OFF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002291
Application pin number . . . 834459
Page 3
Date 8/17/07
Special Notes and Comments
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
BUILDING DEPT REPRESENTA'
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002291
Application pin number . . . 834459
Page 4
Date 8/17/07
Special Notes and Comments
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20%
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
Other Fees SEWER TAP 4"
WATER TAP 3/4"
350.00
400.00
Fee summary Charged Paid Credited Due
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
----------------- ----------
Permit Fee Total 499.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1249.00
--------------------------
BUILDING DEPT REPF
APPLICANT:
Page
5
07-00002291
Date
8/17/07
834459
--------------------
499.00
----------
.00
.00
.00
.00
.00
750.00
.00
.00
1249.00
.00
.00
TEMPORARY POLE PERMIT
o' CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00002293 Date 8/17/07
Application pin number . . . 042957
Property Address . . . . . . 915 DOVE LANDING AVE
Property ID: 230100-0309-0310
R #.
Application type description TEMP POLE
Subdivision Name . . . . . . DOVE CROSSING PH 3
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
CLASSIC CENTURY HOMES
5001 HWY 287 S
ARLINTON TEXAS
ARLINGTON
TX 76017
(817) 561-4369
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. GS
Permit pin number
. 519934
Permit Fee . . .
. 20.00
Issue Date . . .
. 8/17/07
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
------------------------------
Due
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
----------------------------------------------------------
BUILDING DEPT REPRESENTATIVE: r
APPLICANT:
Jun •LU U/ UL:U413 ucn - talcs
q
J 4.
Chy op
P1114lSli ,04i(al liS,�i%tnoi'
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION. TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
ADDRESS/LOCATION- I L7
LOT _ZjyBLOCK ._.(3� /�UBDIVISION
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWNER:
y!y oyU oozo P.e-
PHONE: L�� -(�655
PHONE: %- (0q
CONTACT PERSON FOR REVIEW COMMENTS: � ��RR15 PHONE:
FAX: 13Q a EMAIL:
ELECTRICIAN:
HVAC:
PLUMBER:
GOOD CENTS (Residential only):
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION • SLAB ONLY
DUPLEX (Landscape Plans) REMODEURENOVATION` SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:PROPOSED USE: USE: ('12111T/�d(�,-1jAJ
HOMEOWNERASSOCIATIONIARCHITEC7UAL OR DESIGN REVIEW COMMITTEE APPROVAL: yC's
TEXAS ACCESSMILIT/Y STANDA (TAS ROJECT REGISTRATION# EASPRJ_ MIA
VALUATION: $ f 51& TOTAL AREA: � HEATED AREA:
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/rREATMENT SYSTEM
Rr SEWER TAP:
WATER TAP: 3 a%
S ME
OTHER TAP:
S rtE
TEMP PoLe
GARAGE TYPE: SINGLE Q
ATTACHED
SIGNATURE OF APPLICANT:
N UMeER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE ® TRIPLE
DETACHED CARPORT
(��� � S�IE�T�cx.lC
02R KV
�D"�T TAIL ( &�s
i
'If proposed work involves new comma lal a of facade I p emeraslrenevations io an existing
commercial property, building elevatlons are required.
♦����*eeeeseeeeeeeeeeeeeeeeee•e��eeeeeee��♦♦e♦+eee+�esee��e•
Official Use Only
b - 3 - 07
rig Plans Examiner
�G 412^1. wIAN
�14GULzr Aca,�jf
li►l.o�`s� K�uwL
Zoning Official Fire Marshall
ants: �1t5',vu!` SJ—&mI�l2Acr1�
rNO
Jun 1U U/ 01:U5p Ucri - tS/CS y�y vw JocJ �J.J
r
.energy Code Compliance Information
Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling I (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Meat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEEM Rating
Protection Against Subterranean Termites
o
- 1�
IESATT
-3$ 25 L U-6
R • 22 1�F17`j
13
Chemical Tem-dticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
rl Physical3Baniers
® Other
*Verification of Appilcation shall be submitted, to the City of College Station
BwtIdiug Department prior to issuance of the Certificate of Occupancy.
t`
I
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# O -7 _ Z Z 47 (
DATE: W-3 _ O',
BUILDING ADDRESS:
1 S 17o v g— L14 .d
I. Foundation Requirements- Minimum City Foundation Standards
NA/
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
A/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, rade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
OK
A. Stairway Details
&WOK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N O
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
N
Does not block any water course or divert any flow
Elevation certificate needed
jV0
"APPROVED PLANS PER IRC SECTION R106.3.1."
c
L S EXAMINER
k-.,-3'-07
DATE