PREPARED 12/28/07, 8:29:56 INSPECTION TICKET PAGE 1
City.of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/28/07
------------------------------------------------------------------------------------------------
ADDRESS . : 5306 BALLYBUNION CT SUBDIV: PEBBLE CREEK
CONTRACTOR MARIOTT HOMES PHONE (979) 696-1787
OWNER . . PHONE
PARCEL . . 497900-0946-0580
APPL NUMBER: 07-00002276 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 9/07/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00
9/07/07 AP September 7, 2007 8:04:32 AM glsouth.
09/07/2007 04:03 PM RH PDA
Strings up, slab ground installed.
B145 01 9/21/07 JGM BLDG, EXT. SHEATHING FASTENER TIME: 17:00
9/21/07 AP September 20, 2007 4:16:11 PM glsouth.
FRIDAY AFTERNOON
B115 01 10/10/07 JGM BLDG, FRAMING TIME: 17:00
4
10/10/07 AP October 9, 2007 4:36:53 PM acarter.
B130 01 10/12/07 JGM BLDG, INSULATION TIME: 17:00
10/12/07 AP October 11, 2007 2:18:07 PM acarter.
B125 01 12/ 8/A7 I BLDG, FINAL TIME: 17:00
�1 C)C- December 28, 2007 8:29:37 AM acarter.
-------------------------------------- COMMENTS AND NOTES --------------------------------------
n' y 6C0 e7
Iv
Date: 12/28/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 2276
Address: 5306 BALLYBUNION CT
Type
inspection Type Code
Description
p.
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
09/07/2007 04:03 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
M100
MECH, ROUGH IN
IC
10/03/2007 03:24 PM RH PDA
M100
MECH, ROUGH IN
IC
By framing repair duct lines that are partially collapsed
M100
MECH, ROUGH IN
IC
and where inner liners are bunched up at connections
M100
MECH, ROUGH IN
IC
causing air restiction. Inner liners shall be tight and
M100
MECH, ROUGH IN
IC
smooth. Ducts need a long 90 not a short immediate 90
M100
MECH, ROUGH IN
IC
that causes some of these problems.
P105
PLBG, TOP OUT
IC
October 5, 2007 4:38:33 PM kwolfe.
P125
PLBG, FINAL
IC
December 27, 2007 4:39:28 PM kwolfe.
Page 1
Amber Carter - Re: Calling for CO for 5306 Ball bunion Ct 1
From: Mitchell Carson
To: Amber Carter; Benjamin McCarty; Chris Haver; ...
Date: 12/28/2007 4:03 pm
Subject: Re: Calling for CO for 5306 Ballybunion Ct
flagged the sewer box it is broke and needs to be replaced mitch
>>> Amber Carter 12/28/07 8:34 AM >>>
by 07-2276
Any issues?
WF0961645 / 001 City of College Station
PAGE 1
REQ. DATE: 08/29/07 08/29/07 11:11:16
LOCATION: 5306 BALLYBUNION CT LOC ID: 205886
REQUESTOR: MARIOTT HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE:
4" SWR TAP 3/4" WTR TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 08/29/07 SCHED COMPLETION: 08/29/07
********************************************************************************
JOB ORDER RESULT COMMENTS
City of"College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I
C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . .
. . 12/31/07
Parcel Number
497900-0946-0580
Property Address .
. . 5306 BALLYBUNION CT
COLLEGE STATION TX 77845
Subdivision Name .
. . PEBBLE CREEK
Legal Description .
. . PEBBLE CREEK 9-D
BLK 46
LOT 58
Property Zoning . .
. . SINGLE FAMILY RESIDENTIAL
Owner . . . . . . .
. .
Contractor . . . .
. . MARIOTT HOMES
979 696-1787
Application number
07-00002276 000 000
Description of Work
RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy type . .
. . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . .
t
. . //
Approved . . . . . .
Bu' ing Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
Service Treatment Invoice
Route: Map Code:
StartTime: am/pm FlnlshTime: am/pm
Type of Servlce: !Hill Regular Fn)ldw Up Onc Time Charity
Service Addre s
Namc: 07T Nvy+d
Address: D6 twJ� J
City: 61.5 _TX 7%o9r
Phone-
t."EE
r
"Shielding & Protecting
Homes Against Pests"
TPCL#11486
Billing:
v 3 loas _0
Date: �0''�— Appoint -Time:
Frequency: b
TIM Q S YStructure: Crawl P/B Combo
Pets: Dogs) Cat(s) Bird(s) Fish - C,&I&
0
MP
Cost of Service
S
TaN
S
Total Due
$_
Payment
S
Balance
S m
M
Payment by:
Cash O
Check Elk
Credit Card
PEST PROBLEMS: /irL�— �aAt�u.e�+ __
DIRECTIONS / INSTRUCTIONS:
..
YAVYIEN 1' DtiE
EQUIP. METIL LOCATION(S)
PRODUCT
Q1'Y TARGET PEST(S) UPON RECEIPT
WOOD DE TROYING INSECTS
Termidur SC-Fipronil .06%
SuLterrauesn Termites. Ants Size of'rank Posted
_
Termidor80W-Fipntnil.06%
Bora-carc-Disndium 00ahoratcTctroh}•date 50`io
SubterrancanTermites. Size of Tank Posted
Sub Prranean/Formosan/Dr)-ivood'rermites, Carpenter Ants, Beetles, Posted
_
Advance-Balt—Abaneclin .011%
Carpenter Ants
GENER&L PEST-S
Invader APt1.Ba)goul%
_. _ Carpenter Ants, Spiders, Crickets, Millipedes, Dectics,frrmiles.
Denton R'P-C yano-Phenos)pheml
Cockroaches, Millipedes, Sosrbugs, FIIes,Ticks, Mosquitos, Pillhug.,
Dlmelhyc)9evclopmpaneearboxy'late 1 %
Silverfish, Bees, Ants, Carpenter Ants, Scorpions, Splders.
Tempo Ultra WP-Cyfluthrin .025% (Rest)
_..._ Ants (Except Pita raoh),Cock roaches, Crickets, Earwigs, Millipedes, Flies, fruit Flies, Beetles,
_
(gen. surface spray, spot, Wrist, crack & crevice)
Pillbugs, Silverfish, Spiders. Gnats, Hornels,\Vasps,Yellow Jackets.
Talsmr EZ Blfenthrin .1%
Ants, Centipedes, Cockroaches, Crickets, Grasslwpprrs: Scorpions,Tlcks, Silverfish, Spiders.
Maxforce-Hydramethylon M-2.15141,
Pharaoh Ants, Crickets, CarpcnterAnts, Lg. Ronches,Y:triely of Ants.
_
Cvklck CS Cyfluthrin .05 %
_ Spiders, Scorpions.
_
Phantom .5°/
Pharoh Ants, Varicty of Ants, Roaches.
FLEAS
Tcneard-Pcrmethrin .55a
__ _ Fleas, Ticks, Ants, Centipedes, CarpenterAnIs, Bees, Wasl,.,, Cat penter Bees, Cockroaches,
-
Crickets, Flies, Earsvles, Millipedes, Beetles, Pillhugs.
Suspend SC-Deltanetnrin 4.7., (REST)
pleas, Sees, Beetles, Roacties,Crickets, Lice, Flies, Scorpinnq,Ticks,NVasps.
- _
Nyguatd-Alcthylctnoxy 10% (REST)
IGR-Growth Regulator -pleas, Roaches, Crickets, Flying Insects, Stored Product Pests.
Lacltc R Py rethrin .05%
_ _ Fleas.
141[C1, RODEN FS RATS-11.1OMITORS
Postrac-Broinetholin .01 %
Alice, Rodents, Rats.
_
_ Bait Sta(ion -LargelSmall Glue Boards
Mice, Rodents, Rats, Bug Monitors.
!iT1Ic13
Spec kuz-Pyrocide.50 %
Houseflies, Mosquitas,Aloths, Fleas,N'asps, Hornets,Ticks, Cockroaches.
_
Bifen I!f (tifenthrin .06%
_ Splders, Ants, Roaches, Silverfish, Ear,slgs, Fiens, Scorpions
Fauipment: A -Compressed Sprayer P-Potver Sprayer B-Bait Dispenser BS-DaiL Station 1IT-I1ait Trip D-Aerosol Can G-Glue Board H-Hand Duster S-Spreader F-Fogger Other_
Lneatinns: I -Kitchen 2-Bath(s) J Bedrooms t-Dining Room 5-Utility 6-Storage 7-Common Ar.as 8-Garage 9-Perimeter ol'Structure 111-Attic I I -Yard 12-Under Home 13-Rarehouse Id -Office 15-Exposed Wood 2' up from Slab Other
A'lethod orTreatnients: CC -Crack & Crevice SS -Sub -Slab Injection VT -Void Treatment BP-Hnit Placement BS-Broadcast Spray PB-Perimeter Barrier DV-Drick Venire WI'-Wbud Treatment _,
PRECAUTIONS: Do not ttiuch treated areas till dry. Do not tamper with bait stations. Ventilate rooms after treatment. Keep pets away until pesticides have dried.
Licensed by the Structural Pest Control Board - 333 Guadalupe, Sui(e 1-530 • Austin,TX 78701 •512-305-8250
SERVICE TECHNICIAN: ��- CUSTOivIER SIGNATURE: IF 4 Gti f ec s a,..,, /V!C Imm I0-6`09
Please review the Customer Information ran the other side of Invoice
P.O. Box 9423 • College Station, TX 77842 9 (979) 690-8622 • Fax (979) 690-8840
BUILDING PERMIT
CITY,,OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number
07-00002276 Date 8/29/07
Application pin number
. . . 611576
Property Address . .
. . . . 5306 BALLYBUNION CT
Property ID:
497900-0946-0580
R #:
R
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . PEBBLE CREEK
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 297360
Owner
Contractor
------------------------
------------------------
MARIOTT HOMES
209 ROCK PRAIRIE RD
COLLEGE STATION TX 77845
(979) 696-1787
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 3.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 3304.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 4.50
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 419.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit pin number .
522227
Permit Fee . . . .
1054.00 Plan Check Fee .00
Issue Date . . . .
8/29/07 Valuation . . . . 297360
Expiration Date . .
2/25/08
Qty Unit Charge
Per Extension
BASE FEE 460.00
198.00 3.0000
THOU BLDG, VAL 100001-500000 594.00
----------------------------------------------------------------------------
Special Notes and Comments
-Narrow Wall Bracing
Fully Sheathed with 1 side of Double
Garage being APA Framied with 20" min. OS and Interior
-----------------
BUILDING DEPT REPRESENTATIVE:
-------- ---- -----=---------
APPLICANT:
BUILDING PERMIT
CITY,OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002276
Application pin number . . . 611576
Page 2
Date 8/29/07
Special Notes and Comments
Anchors and Bracing per Plans.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR
ATTACHED GARAGES SHALL HAVE
PENETRATIONS SEALED
Assure Proper GFI Locations,
Outside A/C Unit
GARAGE DOOR HEADER
ALL TOP PLATE AND HEADER
Including One Within 25' Of
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
--------------------------------------------- ----- ---_4-- 1-0 ------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY,OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002276
Application pin number . . . 611576
Page 3
Date 8/29/07
Special Notes and Comments
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
--------------------------------------------�-----� _---=-�_-----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY,OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number 07-00002276 Date 8/29/07
Application pin number . . . 611576
----------------------------------------------------------------------------
Special Notes and Comments
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20%
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ----------' ----------
Permit Fee Total 1054.00 1054.00
Plan Check Total .00 .00
Other Fee Total 750.00 750.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
.00
.00
.00
i$s
--. -- -----------
BUILDING PERMIT
CITY,OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00002276
Application pin number . . . 611576
Grand Total 1804.00 1804.00
Ke
Page
Date
---------------------------------------------✓1-------/---i1----
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
5
8/29/07
M
TEMPORARY POLE PERMIT
CITY,OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00002277 Date 8/29/07
Application pin number . . . 766502
Property Address . . . . . . 5306 BALLYBUNION CT
Property ID: 497900-0946-0580
Application type description TEMP POLE
Subdivision Name . . . . . . PEBBLE CREEK
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
MARIOTT HOMES
209 ROCK PRAIRIE RD
COLLEGE STATION TX 77845
(979) 696-1787
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . KW
Permit pin number . 522201
Permit Fee . . . . 20.00
Issue Date . . . . 8/29/07 Valuation . . . . 0
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 20.00 20.00 .00 .00
Grand Total 20.00 20.00 .00 .00
------------------------------------------
BUILDING DEPT REPRESENTATIVE:
- A. -- AAA , tt34�
APPLICANT:
------4----4-----A--------------
V* hrqq*
CITY OF COLLEGE STATION
Planningo.Dtve%pm nt'Seivice{
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.C//STX.GOV %
ADDRESS/LOCATION: ��� W l i
LOT vBLOCK UBDIVISION
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWNER:
CONTACT PERSON FOR REVIEW COMMENTS:
ELECTI
HVAC:
ACCESSORY/STORAGE
ADDITION
DEMOLITION (Asbestos Survey)
DUPLEX (Landscape Plans)
DESCRIPTION OF WORK:
PROPOSED USE:
For Office Use Only
DATE ° 3 ORCC REG
APPLICATION # °rw
TEMP POLE # M °
-7
PHONE:
PHONE:
' 4 PHONE: q` O��""L��7[j
EMAIL: e-"4f x C'o0� S �
PLUMBER:
GOOD CENTS (Residential only):
LOCATION
ING
EW CONSTRUCTION '
RE MODE URENOVATION'
RE -ROOF
SHELL ONLY
SLAB ONLY
SWIMMING POOL
TENT/CANOPY
HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ V, 3j `/ TOTAL AREA: _�� HEATED AREA:
(Cost of Labooi a� aterials) q
UBLIC SEWER NUMBER OF BEDROOMS:
❑ SEPTIC/TREATMENT SYSTEM
it
SEWER TAP: `/
�/ATER TAP
OTHER TAP:
VEMP POLE
GARAGE TYPE:
SIZE
SIZE
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE
FOUNDATION TYPE
ROOF TYPE:
SINGLE OUBLE a
ATTACHED DETACHa
TRIPLE
CARPORT
SIGNATURE OF APPLICANT: JA"P � i �//
'If proposed work involves new commercla construction or a de improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
�B 9-1-17
�IFr Plans Examiner
Zoning Official /' r_:; KAa�rsh�all
�
C ents: ry � � -) hA4 r j'AV U! j�'�f3 1 Sf�d..
ES r NO o4- 14**3�6 f,,4ox,1A-
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (Vaulted'areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
16.T�o
Chemical Termiticide Treatment (Soil Treatment)
l
a38
55
e'OChemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# O _
DATE: v'
BUILDING ADDRESS:
3 0 ID LjOictJ C*
I. Foundation Requirements- Minimum City Foundation Stan ards
NA/
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
O
II. Framing:
Floor, Wall, Ceiling and Roof Requirements
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
O
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
J
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
UOK
A. Stairway Details
K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairwa
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NAMW
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NAf0jW
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
K
np
"APPROVED PLANS PER IRC SECTION R106.3.1."
PLANS EXAMINER
f-lL-o7
DATE
530�
BALLYBUN ION COURT
8-2 ne'1:
PR PERTY LINE: 112.00' - 39°34 5g' E
N
25.0' ING SETi CK LINE 1 1
'
O Zi r ��
1. A
Ul
WA
►� (11 � .,,� :4a.�* n a1,�g }es,�;d�.;y,�,•pi£�''�3`v�`. �n 1(jl W `�O/i
2 S
UILDING SETBACK LI
QZ 1
-a. --- - �►'-------------------
10.0 PUBLIC UTILITY EASE I1 T t____ —
1
— — 1
PROPERTY LINE: 13q.40' - N 38°1 '08" W —1-
1
1
q' --I It
lo
3'-6n
01 51TE PLAN�,.0
��
l \
I
LOT: 58
BLOCK: 46
SUBDiVISION:
PEBBLE CREEK k
PHASE q-D
COLLEGE STATION, TX
BRAZOS COUNTY