PREPARED 3/11/08, 12:01:47 INSPECTION TICKET PAGE 2
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/11/08
------------------------------------------------------------------------------------------------
ADDRESS . : 1016 LYCEUM CT SUBDIV: UNIVERSITY PRESERVE
CONTRACTOR ARMATYS CUSTOM HOMES PHONE (979) 693-8584
OWNER CRUX FINANCIAL SERVICES INC PHONE
PARCEL 620800-0001-0080
APPL NUMBER: 07-00002275 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 8/24/07 DS BLDG, FOUNDATION -SLAB TIME: 17:00
8/24/07 AP August 24, 2007 9:11:44 AM acarter.
doesn't think that it will be ready until 3
B115 01 11/26/07 DS BLDG, FRAMING TIME: 17:00
11/26/07 AE November 26, 2007 9:37:41 AM acarter.
'+ 11/26/2007 04:36 PM DS PDA
fireblock top of column in dinning room and top and back
pony wall of fire place
B13C?-01 12/06/07 DS BLDG, INSULATION TIME: 17:00
12/06/07 AP December 6, 2007 11:43:33 AM kwolfe.
B125.01 3/11/08 BI BLDG, FINAL TIME: 17:00
Ac March 11, 2008 11:58:56 AM kwolfe.
-------------------------------- - - - - -- COMMENTS AND NOTES -----------------------------
-
- '�DTA�SS IJ�OS -ro � O� 'Fi2a.C� o� clv�� oti
C, 0 ,
TAR
Date: 3/11 /2008
Inspection Comments for Final,
Permit Year: 7 permit Number: 227E
Address: 1016 LYCEUM CT
TYPe
Inspection Type Code
Description
status
Inspection Result Comments
B115
BLDG, FRAMING
IC
11/26/2007 04:36 PM DS PDA
6115
BLDG, FRAMING
IC
fireblock top of column in dinning room and top and back
B115
BLDG, FRAMING
IC
pony wall of fire place
E110
ELEC, ROUGH IN
IC
11/26/2007 04:41 PM DS PDA
E110
ELEC, ROUGH IN
IC
add receptial in middle bedroom
M100
MECH, ROUGH IN
IC
August 15, 2007 11:18:41 AM kwolfe.
M100
MECH, ROUGH IN
IC
wrong house - contractor pulled the wrong permit at the
M100
MECH, ROUGH IN
IC
wrong house and we went out. The work had been done at
1014
M100
MECH, ROUGH IN
IC
three days before permit pulled. Since permit was already
M100
MECH, ROUGH IN
IC
pulled we could not double charge. So David red tagged
.L.:-
M100
MECH, ROUGH IN
IC
inspection for making us go to wrong house.
M110
MECH, FINAL
IC
SHOULD HAVE BEEN A MECH ROUGH IN INSPECTION
Page 1
WF0946108 / 001 City of C:cdilege Station PAGE 1
REQ. DATE: 08/06/07 08/06/07 13:55:28
LOCATION: 1016 LYCEUM CT LOC ID: 196216
REQUESTOR: ARMATYS CONSTRUCTION ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 08/06/07 SCHED COMPLETION: 08/06/07
JOB ORDER RESULT CONIIK=S
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 778-4-0
C E R T I F I
C A T E O F O C C U P A N C Y
T E M P O R A R Y
Issue Date . . . . .
. 3/13/08
Expiration Date . . .
. 3/28/08
Parcel Number . . . .
. 620800-0001-0080
Property Address . .
. 1016 LYCEUM CT
COLLEGE STATION TX 77840
Subdivision Name . .
. UNIVERSITY PRESERVE
Legal Description . .
. UNIVERSITY PRESERVE, BLOCK 1,
LOT 8
Property Zoning . . .
. UNKNOWN
Owner . . . . . . . .
q
. CRUX FINANCIAL SERVICES INC
Contractor . . . . .
. ARMATYS CUSTOM HOMES
979 693-8584
Application number 07-00002275 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . .
Special conditions
ADDRESS NEEDS TO BE ON FRONT OF HOUSE OR BOTH SIDES OF
MAILBOX.
Approved
J
C -� Q
Building fficial
VOID UNLESS SIGNED BY BUILDING OFFICIAL
City of College Station
11Y01 TEXAS AVENUE
COLLEGE STATION TX 77840
T E M P O R A R Y C O
T E M P O R A R Y
Issue Date . . . . . .
Expiration Date . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning
3/13/08
4/04/08
620800-0001-0080
1016 LYCEUM CT
COLLEGE STATION TX 77840
UNIVERSITY PRESERVE
UNIVERSITY PRESERVE, BLOCK 1,
LOT 8
UNKNOWN
Owner . . . . . . . . . CRUX FINANCIAL SERVICES INC
Contractor . . . . . . ARMATYS CUSTOM HOMES
979 693-8584
Application number 07-00002275 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Special conditions . .
ADDRESS NEEDS TO BE ON FRONT OF HOUSE OR BOTH SIDES OF
MAILBOX.
Approved . . . . . . .
%Uydr1 •-
ng officia
VOID UNLESS SIGNED BY BUILDING OFFICIAL
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00002361 Date 8/07/07
Application pin number . . . 490194
Property Address . . . . . . 1016 LYCEUM CT
Property ID: 620800-0001-0080
R #: R114846
Application type description TEMP POLE
Subdivision Name . . . . . . UNIVERSITY PRESERVE
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
CRUX FINANCIAL SERVICES INC ARMATYS CUSTOM HOMES
1017 LYCEUM CT 2706 WINGATE
COLLEGE STATION TX 778402342 COLLEGE STATION TX 77845
(979) 693-8584
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . GS
Permit pin number 517722
Permit Fee 20.00
Issue Date 8/07/07 Valuation . . . . 0
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 20.00 20.00 .00 .00
Grand Total 20.00 20.00 .00 .00
------------------------- -----------------
BUILDING DEPT REPRESENTATIVE: '�r
APPLICANT:
BUILDING PERMIT,.., a
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
`PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00002275 Date 8/06/07
Application pin number . . . 456650
Property Address . . . . . . 1016 LYCEUM CT
Property ID: 620800-0001-0080
R #: R114846
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . UNIVERSITY PRESERVE
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation 220000
Owner Contractor
------------------------ ------------------------
CRUX FINANCIAL SERVICES INC ARMATYS CUSTOM HOMES
1017 LYCEUM CT 2706 WINGATE
COLLEGE STATION TX 778402342 COLLEGE STATION TX 77845
(979) 693-8584
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) ice.
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
.TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2929.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 246.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit pin number . 517318
Permit Fee . . . . 820.00 Plan Check Fee .00
Issue Date . . . . 8/06/07 Valuation . . . . 220000
Expiration Date 2/02/08
Qty Unit Charge Per Extension
BASE FEE 460.00
120.00 3.0000 THOU BLDG., VAL 100001-500000 360.00
----------------------------------------------------------------------------
Special Notes and Comments
-Add Smoke detectors per plans
-Narrow Wall Bracing Fully Sheathed with PA Framing in
BUILDING DEPT REPRESSNTATIVY.
APPLICANT:
' BUILDING PERMIT ,
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002275
Application pin number . . . 456650
Page 2
Date 8/06/07
Special Notes and Comments
several locations throughout house per plans.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR
ATTACHED GARAGES SHALL HAVE
PENETRATIONS SEALED
Assure Proper GFI Locations,
Outside A/C Unit
GARAGE DOOR HEADER
ALL TOP PLATE AND HEADER
Including One Within 25' Of
PLATFORM FOR MECHANICAL EQUIPMENT AND/O ACCESS MAY HAVE TO
-------------------------------------------------`-- 4_66046� ----------
BUILDING DEPT REPRESIKTATIVV.
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 07-00002275 Date 8/06/07
Application pin number . . . 456650
----------------------------------------------------------------------------
Special Notes and Comments
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE.UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required.. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
------------------------------------------- ----- -- ------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT •
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002275
Application pin number . . . 456650
Page 4
Date 8/06/07
Special Notes and Comments
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 200
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Other Fees SEWER TAP 4"
WATER TAP 3/4"
65.00
200.00
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 820.00 820.00 .00 .00
Plan Check Total .00 .00 .00 .00
-------------------------------------------- ----- -------------
BUILDING DEPT REPRESS TATIVE•.'
OF
APPLICANT:
• BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00002275
Application pin number . . . 456650
Other Fee Total 265.00 265.00
Grand Total 1085.00 1085.00
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ----
BUILDING DEPT�JREPRESENTATIV
APPLICANT: /�
Page 5
Date 8/06/07
.00 .00
.00 .00
J A
CITY OF COLLEGE STATION
Planning d Development Snvicrt
ADDRESS/LOCATION
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
• i rvr Office Use Onty
DATE: TRCC REG
APPLICATION # 0 tea
TEMP POLE #
LOT O BLOCK SUBDIVISION Uti)aee s i l y SEC/PH
BUSINESS/OWNER NAME: /M, P_ PHONE: %079 %,f% q
CONTRACTOR/HOMEOWNER: &1vLJy5 ("mc� 5 �rv���� K— PHONE:
CONTACT PERSON FOR REVIEW COMMENTS: /"QX 1-PPI S PHONE:
FAX: a/%9 to93EMAIL: a,rMa-4v5 9 4a Pt vle�'
ELECTRICIAN: -&e.1 405C PLUMBER: Pa ,t1. /,-
HVAC: 0Bv,4,,1 /et.,�P GOOD CENTS (Residential only):
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) 1---NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEURENOVATION" SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE: IC 5de,4 1' I
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 02a V TOTAL AREA:, 38 1( HEATED AREA: 9 a
(Cost of Labor and Materials)
VPUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
J [ / l� J,
dSEWER TAP: `1 � •
SIZE YWATER TAP: 3 SIZE „ " 42,0
❑ OTHER TAP:
SIZE
li�(TEMP POLE
GARAGE TYPE: SINGLE
ATTACHED
NUMBER OF BEDROOMS
-5
NUMBER OF BATHROOMS: 3
INTERIOR WALL TYPE: wdlpyAlwIla%,4e 4ld�ocG//_
EXTERIOR WALL TYPE: lklmdlF-I'a 0-2 J4r/A
FOUNDATION TYPE:
ROOF TYPE: 3Oyit �01� f P_
DOUBLE TRIPLE
I - I DETACHED �a CARPORT a
SIGNATURE OF APPLICANT: / ! VP-- 19`
`If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
-7"G3 s-2-0 7
�FiP Plans Examiner
Zoning Official
D L. oC'+foall Comments:
t����aJ�-a G✓� Seeld r NO
Lpc.c,,�o,,, pee PISS
4ir,earshall
Accev-
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating C"
Protection Against Subterranean Termites
M Chemical Termiticide Treatment (Soil Treatment)
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
+ f .
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# � p
'1 - a�s
DATE:
BUILDING ADDRESS:
l 0 / fo L c ev rA C�•
I. Foundation Requirements- Minimum City Foundation Standards
NA/
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
OK
Il. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
two&
E.
Header sizes indicated on plans
NACW
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduce span)
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
OK
VftOK
A. Stairway Details
OK
1.
Maximum riser height 7-3/4 inches
2.
Minimum tread width 10 inches
3.
Stairway risers are uniform 3/8" Max. difference
4.
Stairway width not less than 36 inches
5.
Stairway headroom not less that six ft. eight 6-8
B. Winder details
1.
Treads a minimum of six 6 inches on narrow edge
2.
Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1.
Riser height less than nine and one-half 9-1/2 inches
2.
Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3.
Stairway width not less than thirty-six inches
4.
Headroom required not less than six ft six 6-6 inches
5.
All treads must be identical
D. Guards/handrail details
1.
Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2.
Handrails are required on stairways located two or more risers above floor/grade
3.
Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4.
Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5.
Guards must be a minimum of thirty-six 36 inches above finished floor
6.
Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1.
Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2.
Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry
fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/ K
1.
Electrical fixtures & switches indicated
2.
Smoke detector locations indicated as required
3.
GFI circuits indicated where required
4.
Arc fault protection for bedroom circuits
5.
Panel location
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NAA
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N 410-0
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
" L �_,
ANS EXAMINER
DATE