Loading...
HomeMy WebLinkAboutRES2007-02257, 07-2490obi-�u� G►ernPi City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 12/31/07 Parcel Number . . . . . 230100-0102-0100 Property Address . . . 3718 DOVE HOLLOW LN COLLEGE STATION TX 77845 Subdivision Name . . . Legal Description . . . DOVE CROSSING PH 1C BLK 2 LOT 10 Property Zoning . . . . SINGLE FAMILY RESIDENTIAL Owner . . . . . . . . . Contractor . . . . . . ED FROEHLING BUILDERS 979 776-8266 Application number 07-00002257 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . // Approved . . . . . . Bu' i g O ficial VOID UNLESS SIGNED BY BUILDING OFFICIAL PREPARED 12/28/07, 9:14:04 INSPECTION TICKET PAGE 1 City of ------------------------------------------------------------------------------------------------ College Station INSPECTOR: BUILDING INSPECTOR DATE 12/27/07 ADDRESS . : 3718 DOVE HOLLOW LN SUBDIV: CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER . . PHONE PARCEL . . 230100-0102-0100 APPL NUMBER: 07-00002257 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 9/14/07 RH BLDG, FOUNDATION -SLAB TIME: 17:00 9/14/07 AP September 14, 2007 10:25:03 AM acarter. 09/14/2007 02:14 PM RH PDA Strings up, slab ground installed. B120 01 9/25/07 OC BLDG, FRAMING -PARTIAL TIME: 17:00 9/25/07 AP September 24, 2007 2:55:51 PM acarter. APA NAILING INSPECTIONS B115 01 10/19/07 OC BLDG, FRAMING TIME: 17:00 10/19/07 AP October 18, 2007 3:44:42 PM glsouth. B130 01 10/30/07 RH BLDG, INSULATION TIME: 17:00 10/30/07 AE October 30, 2007 8:54:11 AM acarter. 10/30/2007 03:57 PM RH PDA Repair and seal all holes in Tyvek be ore brick. B125 01 12/27/07 BBI- BLDG, FINAL TIME: 17:00 () /at10.1 IF OC. December 28, 2007 9:13:19 AM acarter. -------------------------------------- COMMENTS AND NOTES-------------------------------------- Date: 12/28/2007 Inspection Comments for Finals Permit Year: 7 Permit Number: 2257 Address: 3718 DOVE HOLLOW LN Insp. inspection Type Code p. Status Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC 09/14/2007 02:14 PM RH PDA B100 BLDG, FOUNDATION -SLAB IC Strings up, slab ground installed. B130 BLDG, INSULATION IC 10/30/2007 03:57 PM RH PDA Rim RI nr. INSI11 ATION IC Renair and seal all hnles in Tvvek he nre hrirk WF0949180 / 001 City of College Station PAGE 1 REQ. DATE: 08/09/07 08/09/07 10:50:27 LOCATION: 3718 DOVE HOLLOW LN LOC ID: 205470 REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE: WTR 3/4" SWR 4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 08/09/07 SCHED COMPLETION: 08/09/07 ******************************************************************************** JOB ORDER RESULT CON14ENTS Amber Carter - Re Calling for CO for 3718 Dove Hollow Ln From: Terry Boriskie To: Amber Carter; Benjamin McCarty; Chris Haver; ... Date: 12/28/2007 4:20 pm Subject: Re: Calling for CO for 3718 Dove Hollow Ln Contacted Builder Froehling Homes at 776-8266. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Paul Schoenfeld 12/28/2007 2:23 pm >>> NO FOR CO. Water meter box broken. Sewer buried flagged. Paul >>> Amber Carter 12/28/2007 9:16 AM >>> by 07-2257 Any issues? TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE d� • Z2� COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Application pin number . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 07-00002490 Date 8/16/07 618070 3718 DOVE HOLLOW LN 230100-0102-0100 R TEMP POLE RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 -------------------------- Permit . . . . . 7------------------------------------------------- . TEMP POLE PERMIT Additional desc . . AC Permit pin number . 519728 Permit Fee . . . . 20.00 Issue Date . . . . 8/16/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------------------------------------------- BUILDING DEPT_ WPRESENTATIVE : e APPLICANT: -t--- - - - - -- /2007 09:21 FAX 9797740565 Ed Froehling Builder Inc Ron SUBTERRANEAN TERMTE PRECONSTRUCnON DISCLOSURE FOR EACH ESTYMATE For all treatments there will be a.diagram showing exactly what will be treated prior to the beginning of treatment. Review the pesticide label provided to you at this time for minimum treatment standards. Remember that your architects or design engineers specifications must also be followed, unless they are in violation of the law. Review the consumer information sheet for further information. If you have any questions, contact the pest control company or the Texas Structural Pest Control Board, PO Box 1927, Austin, Texas 78767-1927. Telephone number (512) 305-8250. Name of Customer . T� Address City. State Zip Location to be Treated J u t� . r `�0� C'4115 Type of -Treatment: [ ] Full [ Partial A label of l S termiticide(s) is enclosed. The percentage of the termiticide(s) to be applied at this location is C Warranty Information provided must include the Complete Details of any Warranty provided and the following: Time Period of Warranty; Renewal Options and Cost; and Ob gatdons of the Contracting Parties. If the warranty does not include the entire structure treated, the areas included in the warranty are: (specify) . ~Total Square Feet to be Treated: Total Linear Feet to be Treated:/1 Approximate Measurements of the Structure(s) to be Treated: of CertifedApplicator or printed Namr z Completing Estimate Name of Pest Control Company TPCL_ No. Date Licensed and regulated under the Texas Structural Pest Control Act Texas Stt uctural,Pest Control Board, PO'Box 1927, Austin, Texas 78767-1927, Telephone number (512) 305-8250. Sample Form — April 4, 2005 Page 1 of 2 12/31/2007 09:20 FAX 9797740565 Ed Froehling Builder Inc Q 002 ACE PEST CONTROL T.P.C.L. It 7120 PT PO BOX 4474 BRYAN, TX 77805 (979) 823-7777 (979) 7744736 CERTIFICATE The following property 3718 DOVE 1QOLLOW built by F'ROMLING HOMES State of Texas County of BRAZ S the city of COLLEGE STATION N lailing Address SAME Zip code 77845 was treated for subterranean termites on this day SEPTEMB R 13 2007 and has met with approval. Cost of initial treatment, 352.83 is payable upon completion of work. The treatment is: guaranteed for 12 months from the date of treatment. Thereafter, this contract is subject to annual renewal (OPTIONAL) upon payment of annual inspection and renewal fee of S 125 talus tax, for a period of_ 4 years. ( see attached letter ) If at any time during this contract a reinfestation of subterranean termites should occur, the above said property will be treated at no additional cost to the owner. ACE PEST CONTROL does not accept any liability for any subterranean termite damage repair. Failure to pay the annual renewal fee within thirty days after the inspection date shall be construed as a cancellation of this contract. .Any alteration or addition to the foundation of the above described property without proper termite treatment by ACE PEST CONTROL Services shall nullify this contract. Licensed and regulated by Structural Pest Control Board P.O. BOX 1927 Austin, TX 78767-1927 (512) 305-8250 BUILDING PERMIT CITY OF COL&EGE_.STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number 07-00002257 Date 8/02/07 Application pin number . . . 487395 Property Address . . . . 3718 DOVE HOLLOW LN Property ID: 230100-0102-0100 R #: R Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 125004 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1894.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . AC Permit pin number . 516963 Permit Fee . . . . 538.00 Plan Check Fee .00 Issue Date . . . . 8/02/07 Valuation . . . . 125004 Expiration Date . . 1/29/08 Qty Unit Charge Per Extension BASE FEE 460.00 26.00 3.0000 THOU BLDG, VAL 100001-500000 78.00 ---------------------------------------------------------------------------- Special Notes and Comments -20' Rear PUE and Setback -Narrow Wall Bracing Fully Sheathed ---- ----------------------- BUILDING DEPT REPRESENTATIVE: - ------ --- -- ------------- APPLICANT: BUILDING PERMIT CITY OF COLLEGE.STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002257 Application pin number . . . 487395 Page 2 Date 8/02/07 Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES BUILDING DEPT REPRESENTATIVE: • APPLICANT: ' BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002257 Application pin number . . . 487395 Page 3 Date 8/02/07 Special Notes and Comments PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS O SITE LOCATED OFF _ Y ----------------------------------------------- -------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002257 Application pin number . . . 487395 Page 4 Date 8/02/07 Special Notes and Comments THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 200 TO 30% A .35 FACTO OR LOWER SHALL BE MET. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. Other Fees SEWER TAP 4" WATER TAP 3/4" 350.00 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Cre ted Due ---- ------------------------ ------ --- -----jam--------- BUILDING DEPT REPRESENTATIVE: APPLICANT:/ BUILDING PERMIT CITY OF COLLEGE ,STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number Application pin number Permit Fee Total 538.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1288.00 07-00002257 487395 538.00 .00 750.00 1288.00 .00 .00 .00 .00 Page 5 Date 8/02/07 ------------------------ j4440- BUILDING DEPT REPRESENTATIVE:- V APPLICANT: .00 .00 .00 .00 APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE �+ COLLEGE STATION, TX 77840 CITY of Q.:L. ,EGE S2ATl0.rr; (979) 764-3570 (979) 764-3496 FAX Planning l¢;QtvilQpmin t;Seru}teii: WWW.CST X.GOV / ADDRESS/LOCATION: 39Ie� Qr)v, i i—�����L✓ L Pi J ' LOT 10 BLOCK Z 'SUBDIVISION [)oy?e, SEC/PH I BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: c 1;-- ✓Aje)r !,,4— PHONE: 176 076`I� CONTACT PERSON FOR REVIEW COMMENTS: PHONE: 1776 • �i66 FAX: 'oS6� EMAIL: IFo Office Use Only DATE: -5l RCC REG APPLICATION # 01) A6_7 TEMP POLE # ELECTRICIAN: 3 + G r IP.,Ar', PLUMBER: HVAC: JGOOD CENTS (Residential only): ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) 4REMODELJRENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: PROPOSED USE: Si�Q1PJrna HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ i Z54oa4 TOTAL AREA: 2,=t'I'G HEATED AREA: IS 9 (Cost of Labor and• Materials) 52"PUBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM SEWER TAP: 441 WATER TAP: OTHER TAP: TEMP POLE GARAGE TYPE: JIZE 3�14 , j SIZE JIZE SINGLE E] ATTACHED Ez NUMBER OF BEDROOMS NUMBER OF BATHROOMS: INTERIOR WALL TYPE EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE 1z TRIPLE DETACHED F] CARPORT 21 Z SIGNATURE OF APPLICANT - *If proposed work involves new commercial construction or f e improvements/renovations to an existing commercial property, building elevations are required. Official Use Only Z rI P Plans Examiner Zoning Official CO ents: rNO dcfwfj ire Marshall FV It I,y l� Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R' value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork 13 .40 i A/C SEER Rating 3 Protection Against Subterranean Termites dChemical Termiticide Treatment Soil Treatment ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers ❑ Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. 0 .f PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# n -7 ZZ -57 DATE: Z�7 BUILDING ADDRESS: 3 '7 18 Dove Pm I k ow Ltj- I. Foundation Requirements- Minimum City Foundation Standards N A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier Emil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated K 11. Framing: Floor, Wall, Ceiling and Roof Requirements NAW A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in du lex OK 1. One -hour rated extending to roof deck GXOK E. Header sizes indicated on plans NA/ F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations 4 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements QWOK A/ K A. Stairway Details K 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway I 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N ° O A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NAT 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location U PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Re uirements A. Pressure reducing valve required when water pressure exceeds 80 psi N O B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/ A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements K A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 NA/ Does not block any water course or divert any flow Elevation certificate needed &#OK "APPROVED PLANS PER IRC SECTION R106.3.1." PL NS EXAMINER , 0 `Z DATE 20" P.U.E.-- ELEC BOX V FROM CORNER Lot 11 Block 2 Dove Crossing Subdivision Scale: 1 " = 20' N 48 04' 39" W - 56.25' 3718 DOVE HOLLOW LANE 40'-9" 7' Proposed Residence Phase 1 C Lot 10 Block 2 n N LO Lot 9 Block 2 h t� a' I I I I I I o � I �S'MA+c •--+ Concrete Driveway Driveway — — — — — — — — — — — —I— — — — — — — L — — — — — — — — -- � ? I I a N 48 04' 39" W - 56.25' 3718 Dove Hollow Lane 50' R.O.W. - 27' Pavement N REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: Untitled.rck TITLE: 3718 DOVE HOLLOW LANE CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Singl DATE: 07/ 18/07 DATE OF PLANS: 7/13/07 PROJECT INFORMATION: 40.75 LEMKE LOT 10 BLOCK 2 DOVE CROSSING PHASE I COMPANY INFORMATION: ED FROEHLING BUILDER, IT NOTES: HEATED: 1894 TOTAL: 2415 COMPLIANCE: Passes Maximum UA = 698 Your Home UA = 540 22.6% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.35 Ceiling 1: Flat Ceiling or Scissor Wall 1: Wood Frame, 16" o.c. Window l: Metal Frame:Double SHGC: 0.40 Bldg. faces 45 deg. from Nortl Projection factor: 0.29 Door l: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double SHGC: 0.40 Bldg. faces 45 deg. from Nortl Projection factor: 0.29 Permit Number Checked By/Date Wall 3: Wood Frame, 16" o.c. 326 13.0 0.0 18 Window 3: Metal Frame:Double Pane with Low-E 87 0.640 56 SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Back Projection factor: 0.29 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 45 deg. from North; Comp. orient.: Back Projection factor: 0.60 Wall 4: Wood Frame, 16" o.c. 513 13.0 0.0 39 Window 4: Metal Frame:Double Pane with Low-E 41 0.640 26 SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Right Side Projection factor: 0.33 Floor l: Slab -On -Grade: Unheated 209 0.0 218 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 13 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly MECchecl and to comply with the mandatory requirements listed in the RESchecklnspection Checklist. ; �l �7 Builder/Design f Date