C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . . 12/31/07
Parcel Number . . . .
. 230100-0102-0100
Property Address . .
. 3718 DOVE HOLLOW LN
COLLEGE STATION TX 77845
Subdivision Name . .
.
Legal Description . .
. DOVE CROSSING PH 1C
BLK 2
LOT 10
Property Zoning . . .
. SINGLE FAMILY RESIDENTIAL
Owner . . . . . . . .
.
Contractor . . . . .
. ED FROEHLING BUILDERS
979 776-8266
Application number
07-00002257 000 000
Description of Work
RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type .
COMBUSTIBLE (UNPROTECTED)
Occupancy type . . .
. RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . .
. //
Approved . . . . . .
Bu' i g O ficial
VOID UNLESS SIGNED BY BUILDING OFFICIAL
PREPARED 12/28/07, 9:14:04
INSPECTION TICKET PAGE 1
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR DATE 12/27/07
ADDRESS
. : 3718 DOVE HOLLOW
LN SUBDIV:
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER
. .
PHONE
PARCEL
. . 230100-0102-0100
APPL NUMBER: 07-00002257 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
9/14/07 RH
BLDG, FOUNDATION -SLAB TIME: 17:00
9/14/07 AP
September 14, 2007 10:25:03 AM acarter.
09/14/2007 02:14 PM RH PDA
Strings up, slab ground installed.
B120 01
9/25/07 OC
BLDG, FRAMING -PARTIAL TIME: 17:00
9/25/07 AP
September 24, 2007 2:55:51 PM acarter.
APA NAILING INSPECTIONS
B115 01
10/19/07 OC
BLDG, FRAMING TIME: 17:00
10/19/07 AP
October 18, 2007 3:44:42 PM glsouth.
B130 01
10/30/07 RH
BLDG, INSULATION TIME: 17:00
10/30/07 AE
October 30, 2007 8:54:11 AM acarter.
10/30/2007 03:57 PM RH PDA
Repair and seal all holes in Tyvek be ore brick.
B125 01
12/27/07 BBI-
BLDG, FINAL TIME: 17:00
() /at10.1 IF OC.
December 28, 2007 9:13:19 AM acarter.
-------------------------------------- COMMENTS AND NOTES--------------------------------------
Date: 12/28/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 2257
Address: 3718 DOVE HOLLOW LN
Insp.
inspection Type Code
p.
Status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
09/14/2007 02:14 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
B130
BLDG, INSULATION
IC
10/30/2007 03:57 PM RH PDA
Rim
RI nr. INSI11 ATION
IC
Renair and seal all hnles in Tvvek he nre hrirk
WF0949180 / 001 City of College Station
PAGE 1
REQ. DATE: 08/09/07 08/09/07 10:50:27
LOCATION: 3718 DOVE HOLLOW LN LOC ID: 205470
REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 08/09/07 SCHED COMPLETION: 08/09/07
********************************************************************************
JOB ORDER RESULT CON14ENTS
Amber Carter - Re Calling for CO for 3718 Dove Hollow Ln
From: Terry Boriskie
To: Amber Carter; Benjamin McCarty; Chris Haver; ...
Date: 12/28/2007 4:20 pm
Subject: Re: Calling for CO for 3718 Dove Hollow Ln
Contacted Builder Froehling Homes at 776-8266.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld 12/28/2007 2:23 pm >>>
NO FOR CO.
Water meter box broken.
Sewer buried flagged.
Paul
>>> Amber Carter 12/28/2007 9:16 AM >>>
by 07-2257
Any issues?
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE d� • Z2�
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
07-00002490 Date 8/16/07
618070
3718 DOVE HOLLOW LN
230100-0102-0100
R
TEMP POLE
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME
RD
COLLEGE STATION
TX 77845
(979) 776-8266
--------------------------
Permit . . . . .
7-------------------------------------------------
. TEMP POLE
PERMIT
Additional desc .
. AC
Permit pin number
. 519728
Permit Fee . . .
. 20.00
Issue Date . . .
. 8/16/07
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
----------------------------------------------
BUILDING DEPT_ WPRESENTATIVE : e
APPLICANT:
-t--- - - - - --
/2007 09:21 FAX 9797740565 Ed Froehling Builder Inc
Ron
SUBTERRANEAN TERMTE PRECONSTRUCnON
DISCLOSURE FOR EACH ESTYMATE
For all treatments there will be a.diagram showing exactly what will be treated prior to the beginning of
treatment. Review the pesticide label provided to you at this time for minimum treatment standards.
Remember that your architects or design engineers specifications must also be followed, unless they are
in violation of the law. Review the consumer information sheet for further information. If you have any
questions, contact the pest control company or the Texas Structural Pest Control Board, PO Box 1927,
Austin, Texas 78767-1927. Telephone number (512) 305-8250.
Name of Customer . T�
Address
City.
State Zip
Location to be Treated J u t� . r `�0� C'4115
Type of -Treatment: [ ] Full [ Partial
A label of l S termiticide(s) is enclosed.
The percentage of the termiticide(s) to be applied at this location is C
Warranty Information provided must include the Complete Details of any Warranty provided and the
following: Time Period of Warranty; Renewal Options and Cost; and Ob gatdons of the Contracting
Parties.
If the warranty does not include the entire structure treated, the areas included in the warranty are:
(specify) .
~Total Square Feet to be Treated: Total Linear Feet to be Treated:/1
Approximate Measurements of the Structure(s) to be Treated:
of CertifedApplicator or printed Namr
z Completing Estimate
Name of Pest Control Company
TPCL_ No.
Date
Licensed and regulated under the Texas Structural Pest Control Act
Texas Stt uctural,Pest Control Board, PO'Box 1927, Austin, Texas 78767-1927, Telephone number (512) 305-8250.
Sample Form — April 4, 2005
Page 1 of 2
12/31/2007 09:20 FAX 9797740565 Ed Froehling Builder Inc
Q 002
ACE PEST CONTROL
T.P.C.L. It 7120 PT
PO BOX 4474
BRYAN, TX 77805
(979) 823-7777
(979) 7744736
CERTIFICATE
The following property 3718 DOVE 1QOLLOW
built by
F'ROMLING HOMES State of Texas
County of BRAZ S the city of COLLEGE STATION
N lailing Address SAME Zip code 77845
was treated for subterranean termites on this day SEPTEMB R 13 2007 and has
met with approval. Cost of initial treatment, 352.83 is payable upon completion of
work. The treatment is: guaranteed for 12 months from the date of treatment. Thereafter,
this contract is subject to annual renewal (OPTIONAL) upon payment of annual
inspection and renewal fee of S 125 talus tax, for a period of_ 4 years. ( see
attached letter ) If at any time during this contract a reinfestation of subterranean termites
should occur, the above said property will be treated at no additional cost to the owner.
ACE PEST CONTROL does not accept any liability for any subterranean termite damage
repair. Failure to pay the annual renewal fee within thirty days after the inspection date
shall be construed as a cancellation of this contract. .Any alteration or addition to the
foundation of the above described property without proper termite treatment by ACE
PEST CONTROL Services shall nullify this contract.
Licensed and regulated by
Structural Pest Control Board
P.O. BOX 1927
Austin, TX 78767-1927
(512) 305-8250
BUILDING PERMIT
CITY OF COL&EGE_.STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number 07-00002257 Date 8/02/07
Application pin number . . . 487395
Property Address . . . . 3718 DOVE HOLLOW LN
Property ID: 230100-0102-0100
R #: R
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 125004
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME RD
COLLEGE STATION TX 77845
(979) 776-8266
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1894.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
AC
Permit pin number .
516963
Permit Fee . . . .
538.00 Plan Check Fee .00
Issue Date . . . .
8/02/07 Valuation . . . . 125004
Expiration Date . .
1/29/08
Qty Unit Charge
Per Extension
BASE FEE 460.00
26.00 3.0000
THOU BLDG, VAL 100001-500000 78.00
----------------------------------------------------------------------------
Special Notes and Comments
-20' Rear PUE and Setback
-Narrow Wall Bracing
Fully Sheathed
---- -----------------------
BUILDING DEPT REPRESENTATIVE:
- ------ --- -- -------------
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE.STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002257
Application pin number . . . 487395
Page 2
Date 8/02/07
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
BUILDING DEPT REPRESENTATIVE: •
APPLICANT: '
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002257
Application pin number . . . 487395
Page 3
Date 8/02/07
Special Notes and Comments
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS O SITE LOCATED OFF
_ Y
----------------------------------------------- --------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002257
Application pin number . . . 487395
Page 4
Date 8/02/07
Special Notes and Comments
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 200
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
Other Fees SEWER TAP 4"
WATER TAP 3/4"
350.00
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Cre ted Due
---- ------------------------ ------ --- -----jam---------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:/
BUILDING PERMIT
CITY OF COLLEGE ,STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number
Application pin number
Permit Fee Total 538.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1288.00
07-00002257
487395
538.00
.00
750.00
1288.00
.00
.00
.00
.00
Page 5
Date 8/02/07
------------------------ j4440-
BUILDING DEPT REPRESENTATIVE:-
V
APPLICANT:
.00
.00
.00
.00
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
�+ COLLEGE STATION, TX 77840
CITY of Q.:L. ,EGE S2ATl0.rr; (979) 764-3570 (979) 764-3496 FAX
Planning l¢;QtvilQpmin t;Seru}teii:
WWW.CST X.GOV /
ADDRESS/LOCATION: 39Ie� Qr)v, i i—�����L✓ L Pi J '
LOT 10 BLOCK Z 'SUBDIVISION [)oy?e, SEC/PH I
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: c 1;-- ✓Aje)r !,,4— PHONE: 176 076`I�
CONTACT PERSON FOR REVIEW COMMENTS: PHONE: 1776 • �i66
FAX: 'oS6� EMAIL:
IFo Office Use Only
DATE: -5l RCC REG
APPLICATION # 01) A6_7
TEMP POLE #
ELECTRICIAN: 3 + G r IP.,Ar', PLUMBER:
HVAC: JGOOD CENTS (Residential only):
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) 4REMODELJRENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE: Si�Q1PJrna
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ i Z54oa4 TOTAL AREA: 2,=t'I'G HEATED AREA: IS 9
(Cost of Labor and• Materials)
52"PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
SEWER TAP: 441
WATER TAP:
OTHER TAP:
TEMP POLE
GARAGE TYPE:
JIZE
3�14 , j
SIZE
JIZE
SINGLE E]
ATTACHED Ez
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE 1z TRIPLE
DETACHED F] CARPORT
21
Z
SIGNATURE OF APPLICANT -
*If proposed work involves new commercial construction or f e improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
Z rI P Plans Examiner
Zoning Official
CO ents:
rNO
dcfwfj
ire Marshall
FV It I,y l�
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R' value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
13
.40 i
A/C SEER Rating 3
Protection Against Subterranean Termites
dChemical Termiticide Treatment Soil Treatment
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
0
.f
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# n -7 ZZ -57
DATE: Z�7
BUILDING ADDRESS:
3 '7 18 Dove Pm I k ow Ltj-
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
K
11. Framing: Floor, Wall, Ceiling and Roof Requirements
NAW
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in du lex
OK
1. One -hour rated extending to roof deck
GXOK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
4
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
QWOK
A/ K
A. Stairway Details
K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
I
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N ° O
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NAT
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
U
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Re uirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N O
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
K
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
&#OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
PL NS EXAMINER
, 0 `Z
DATE
20" P.U.E.--
ELEC BOX
V FROM CORNER
Lot 11 Block 2
Dove Crossing Subdivision
Scale: 1 " = 20'
N 48 04' 39" W - 56.25'
3718 DOVE
HOLLOW LANE
40'-9" 7'
Proposed
Residence
Phase 1 C
Lot 10 Block 2
n
N
LO Lot 9 Block 2
h
t�
a'
I I
I I
I I
o � I �S'MA+c •--+
Concrete
Driveway
Driveway
— — — — — — — — — — — —I— — — — — — — L — — — — — — — — --
� ? I I
a
N 48 04' 39" W - 56.25'
3718
Dove Hollow Lane
50' R.O.W. - 27' Pavement
N
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: Untitled.rck
TITLE: 3718 DOVE HOLLOW LANE
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Singl
DATE: 07/ 18/07
DATE OF PLANS: 7/13/07
PROJECT INFORMATION:
40.75 LEMKE
LOT 10 BLOCK 2
DOVE CROSSING PHASE I
COMPANY INFORMATION:
ED FROEHLING BUILDER, IT
NOTES:
HEATED: 1894
TOTAL: 2415
COMPLIANCE: Passes
Maximum UA = 698
Your Home UA = 540
22.6% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.35
Ceiling 1: Flat Ceiling or Scissor
Wall 1: Wood Frame, 16" o.c.
Window l: Metal Frame:Double
SHGC: 0.40
Bldg. faces 45 deg. from Nortl
Projection factor: 0.29
Door l: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double
SHGC: 0.40
Bldg. faces 45 deg. from Nortl
Projection factor: 0.29
Permit Number
Checked By/Date
Wall 3: Wood Frame, 16" o.c.
326
13.0 0.0 18
Window 3: Metal Frame:Double Pane with Low-E
87
0.640 56
SHGC: 0.40
Bldg. faces 45 deg. from North; Comp. orient.: Back
Projection factor: 0.29
Door 2: Glass
18
0.580 10
SHGC: 0.78
Bldg. faces 45 deg. from North; Comp. orient.: Back
Projection factor: 0.60
Wall 4: Wood Frame, 16" o.c.
513
13.0 0.0 39
Window 4: Metal Frame:Double Pane with Low-E
41
0.640 26
SHGC: 0.40
Bldg. faces 45 deg. from North; Comp. orient.: Right Side
Projection factor: 0.33
Floor l: Slab -On -Grade: Unheated
209
0.0 218
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchecl and to comply with the mandatory requirements listed in
the RESchecklnspection Checklist.
; �l �7
Builder/Design f Date