HomeMy WebLinkAboutRES2007-02254, 07-22551
10/14/2008 11:02 9797740565 ED FROEHLING BUILDER
PAGE 04/19
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
PmpertyOwner: -FROEH ING HOMES
Location to be Treated: 3712:00VE HOLLOW
�,p roxim to Measures to be—Ueated: 2415
Percentage of Tenn jr, ade(s).to be._apnat this location; �„�o�°(A-81 L.
Tye oMmtmomt Full +l i� _ VgrtiraLX
HorizontallPerimeter Beam XX_
Foundation: S&AR SjdW '"RICK
Primary Jse.LRIES�D—WC �Qaf: COMP051TIQ�
a LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT, WARRANTY INFORMATION (IF ANY)
NCLUDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO'RE-
rREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT
:OULD DEVELOP AS A RESULT OF THE OWNERS ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED,
Charges for pre -treat:
NOTES. Annual re-newal:
$352.83
$126.00
32129 PT 9/3/2007
Co or TechlnNen SPCB Ilcem o # 32129 PT
10/14/2008 11:02 9797740565 ED FROEHLING BUILDER PAGE 05/19
Y :
ACE PEST CONTROL
T.P.C.L. # 7120 PT
PO BOX 4474
BRXAN, TX 77805
(979)823-7777
(979) 774-4736
CE'RTIFICAT.E
The following property 3712 DOVE HOLLOW
built by FROEHLING HOMES State of Texas
County of DRALO the city of COLLEGE STATION
Mailing Address SAME Zip code 77845
was treated for subterranean termites on this day SEPTEMBER 3. 2007 and has met
with approval. Cost of initial treatment, . 352.83 is payable upon completion of work.
The treatment is guaranteed for 12 months from the date of treatment. Thereaficr, this
contract is subject to annual renewal. (OPTIONAL) upori payment of annual inspection
and renewal fee of $ 125 plus tax, for a period of�ears. (sec attacked letter) If
at any time during this contract a reinkstation of subterranean termites should occur, the
above said property will be treated at no additional cost to the owner. ACE PEST
CONTROL does not accept any liability for any subterranean termite damage repair.
Failure to pay the annual renewal fee within thirty days after the inspection date shall be
construed as a cancellation of this contract. Any alteration or addition to the foundation.
of the above described property without proper termite treatment by ACE PEST
CONTROL Services shall nullify this contract,
Licensed and regulated by
Structural. Pest Control Board
P.O. BOX 1927
Austin, TX 78767-1.927
(512) 305-8250
I
WFO949197 / 001 City of College*Srt& 5,ion
PAGE 1
REQ. DATE: 08/09/07 08/09/07 10:54:51
LOCATION: 3712 DOVE HOLLOW LN LOC ID: 205464
REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ USER: ACARTER AUTH USER:ACARTER WRK TYPE:
WTR 3/4" SWR 4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 08/09/07 SCHED COMPLETION: 08/09/07
********************************************************************************
JOB ORDER RESULT COM UKRTS
PREPARED
10/14/08, 12:01:49
INSPECTION TICKET
PAGE 4
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 10/14/08
ADDRESS
. : 3712 DOVE HOLLOW IN SUBDIV:
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER .
.
PHONE
PARCEL .
. 230100-0102-0070
APPL NUMBER: 07-00002254 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
9/04/07 RH
BLDG, FOUNDATION -SLAB TIME: 17:00
9/04/07 AP
September 4, 2007 11:44:05 AM acarter.
09/04/2007 03:34 PM RH PDA
Strings up, slab ground installed.
B115 01
11/06/07 RH
BLDG, FRAMING TIME: 17:00
11/06/07 AE
November 6, 2007 10:16:06 AM kwolfe.
11/06/2007 03:20 PM RH PDA
Tape seal all holes through Tyvek before foam insulation.
B130 01
11/14/07 RH
BLDG, INSULATION TIME: 17:00
4
11/14/07 AP
November 14, 2007 8:24:23 AM acarter.
B125 01
10/14/08 BI
BLDG, FINAL TIME: 17:00
October 14, 2008 11:54:08 AM glsouth.
�--------------
M
-----------------------------------
COMMENTS AND NOTES -------A
-
Date: 10/15/2008
[nspection Comments for Final
Permit Year: 7 'ermit Number: 2254
Address: 3712 DOVE HOLLOW LN
Type
Inspection Type Code
s asps
Inspection Result Comments
Description
B100
BLDG, FOUNDATION-SL,
IC
09/04/2007 03:34 PM RH PDA
B100
BLDG, FOUND ATION-SLj
IC
Strings up, slab ground installed. '
B115
BLDG, FRAMING
IC
11/06/2007 03:20 PM RH PDA
6115
BLDG, FRAMING
IC
Tape seal all holes through Tyvek before foam insulation.
City of College Station
1101 TEXAS -AVENUE
COLLEGE STATION TX 77840
C E
R
T
I
F
I
C A T E
O F
O C
C
U
P
A
N
C Y
P E R M
A N E
N T
Issue Date . . . . . . 10/16/08
Parcel Number 230100-0102-0070
Property Address . . . 3712 DOVE HOLLOW LN
COLLEGE STATION TX 77845
Subdivision Name
Legal Description DOVE CROSSING PH 1C
BLK 2
LOT 7
Property Zoning . . . . SINGLE FAMILY RESIDENTIAL
Owner . . . . . . . . .
Contractor . . . . . . ED FROEHLING BUILDERS
979 776-8266
Application number 07-00002254 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . . i
Ic A -,
Approved . . . . . .
Bu' i g Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
BUILDING PERMIT
CITY OF f Cq".. jFGE , STATION
1101 TEXAS AVENUE, COLLEGE:STATI'ON, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bp'lnspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .07-00002254 Date 8/02/07
Application pin number . . . 712344
Property Address . . . . . . 3712 DOVE HOLLOW LN
Property ID: 230100-0102-0070
R #: R
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation 125004
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME
RD
COLLEGE STATION
TX 77845
(979) 776-8266
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info
EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1894.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
AC
Permit pin number .
516930
Permit Fee . . . .
538.00 Plan Check Fee
.00
Issue Date . . . .
8/02/07 Valuation . . .
. 125004
Expiration Date . .
1/29/08
Qty Unit Charge
Per
Extension
BASE FEE
460.00
26.00 3.0000
THOU BLDG, VAL 100001-500000
78.00
----------------------------------------------------------------------------
Special Notes and Comments
-Narrow Wall Bracing
Fully Sheathed
-Rear 20' PUE and Setback
-------------------------------
BUILDING DEPT REPRESENTATIVE:
----- --
--' ------
APPLICANT:
BUILDING PERMIT
CITY OF.COLLFGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002254
Application pin number . . . 712344
Page 2
Date 8/02/07
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
---------------------------------------------- ----- -- �__
---------
BUILDING DEPT REPREUNTATIVE:
V
APPLICANT: —y
BUILDING PERMIT
CITY OF,COLLF'GE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002254
Application pin number . . . 712344
Page 3
Date 8/02/07
Special Notes and Comments
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
--------------------------------------------- ------ ------ --------------
BUILDING DEPT REPRESENTATIVE: `
APPLICANT:
BUILDING PERMIT
CITY OF.COLLFGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number 07-00002254
Application pin number . . . 712344
Page 4
Date 8/02/07
Special Notes and Comments
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 2001 A .40 OR LOWER FACTOR AND ABOVE 200-o
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
Other Fees . . . .
SEWER TAP 4"
WATER TAP 3/4"
350.00
400.00
----------------------------------------------------------------------------
-
----Feesummary--Charged--Paid ---- Credit d .Due
- ---- -- _-----
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF -COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . .
Application pin number . . .
----------------- ----------
Permit Fee Total 538.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1288.00
Page
5
07-00002254
Date
8/02/07
712344
--------------------
538.00
----------
.00
.00
.00
.00
.00
750.00
.00
.00
1288.00
.00
.00
-----------------------------------� -- ---- _-----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF -COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION. TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 07-00002255 Date 8/02/07
Application pin number . . . 248805
Property Address . . . . . . 3712 DOVE.HOLLOW LN
Property ID: 230100-0102-0070
R #: R
Application type description TEMP POLE
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME
RD
COLLEGE STATION
TX 77845
(979) 776-8266
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. AC
Permit pin number
. 516948
Permit Fee . . .
. 20.00
Issue Date . . .
. 8/02/07
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total'
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT REPRESENTATIVE: _46-
--I- ------
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CMQOLLP-a.STATAQ (979) 764.3570 (979) 764.3408 FAX
kdm4i 'dT7 h i��sa`at„.
WYYW.CSTX.GOV
DATE:
APPLIOATION
TEMP POLE 0
ADDRESS/LLOCATION:_�.; / 1 -L— �✓�"� � �`�''°`� `��'-- —
LOT �! BLOCK Z._ SUBDIVISION Q21J& G! PHONE:
ONE: H..
BUSINESSIOWNER NAME:
O
CONTRACTOWHOMEC�WNER: �ro�, ��� �^G.Pr�oNe: _n?6- 6Z6�
CONTACT PERSON FOR REVIEW COMMENTS: _ M _ PHONE:
FAX: 'I% 4 •0�^�� w
ELECTRICIAN: zAdz,
HVAC: J 6
EMAIL: __ —
PLUMBER: _ j S
GOOD CENTS (Residential only):
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION OVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION' SLAB ONLY
SWIMMING DUPLEX (Landscape Plans) REMODELIRENOVATIO N' TENT CANOPYOL
DESCRIPTION OF WORK:
PROPOSED USE: S;�_ ��r✓�11 e
l� REVIEW COMMITTEE APPROVAL: _
HOMEOWNER ASSOCIA'TIONiARCHITECTI/AL OR Dr=.,ICN REV
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EASPRJ _
VALUATION: $ I Z TOTAL AREA: 2 HEATED AREA:
(Cost of Lbbar and Materials)
E2/P`UBLIC SEWER NuMaER OFF BEDROOMS:
SEPTIG%TREATMENT SYSTEM NUMBER OF BATHSOOMS: Z
EWER TAP; +11 INTERIOR WALL TYPE:�-
SI:�
WATER TAP: EXTERIOR WALL TYPE.
' SIZE
L1 OTHER TAP:
' FOUNDATION TYPE: 1 GJ CY1
TEMP POLE ROOF TYPE:
GARAGE TYPE: SINGLE • DOUBLE [d TRIPLE p
ATTACHEDDETACHED CARPORT
SIGNATURE OF APPLICANT:
`If proposed work involves new commercial Construction or facade Improve jrenovations to an existing
.commercial property, building elevations are required.
00000000000000000000000000000s®0000s0000e0000e0000se0000.000♦
Olf clal Use Only
0?
�P Plans Examiner
31aCJtzc Avers
Zoning Official ✓ Fine Marshall
C mments: _ �v(1 �) c
�or NO
Energy Code Compliance Information
% Glazing of exterior walls 12 6 of
Insulation R value of exterior walls 13
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic) �J/�
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork /
AJC SEER Rating 13 /
Protection ,against Subterranean. Termites
lid Chemical Termiticide Treatment (Soil Treatment)
❑ Chenti.cal Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Yeriiacation of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
�0
-f
. PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
v�- easy
DATE:
BUILDING ADDRESS:
3 I a, bave (A-0 1 0 LW .
I. Foundation Requirements- Minimum City Foundation Standards
N K
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
K
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
K
1. One -hour rated extending to roof deck
ZPOK
E.
Header sizes indicated on plans
N
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing plan or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q.
Tempered Glass required in all hazardous locations
i
. PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
K
&OK
A. Stairway Details
K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N O
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
N
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
I
• PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
N
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NAM
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N O
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NIAIW
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
NA/
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
COOK
"APPROVED PLANS PER IRC SECTION R106.3.1."
LANS EXAMINER
�- 2 - D?
DATE
l
20" P
Dove Crossing Subdivision
Scale: 1 " = 20'
N 48 04' 39" W - 56.25'
40'-9"
ELEC BOX
1' FROM CORNER 3712 DOVE
HOLLOW LANE
N
LO (V
Proposed
Residence
Phase 1C
Lot 7 Block 2 N
Lot 8 Block 2 N � Lot 6 Block 2
zo h
0) N
7'-9„
N Concrete
N L5, orivewaY
—..-� —--------
Ln
N 48 04' 39" W - 56.25'
Dove Hollow Lane
50' R.O.W. - 27' Pavement
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: Untitled.rck
TITLE: 3712 DOVE HOLLOW LANE
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 07/18/07
DATE OF PLANS: 7/13/07
PROJECT INFORMATION:
40.75 LEMKE
LOT 7 BLOCK 2
DOVE CROSSING PHASE I
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC.
NOTES:
HEATED: 1894
TOTAL: 2415
COMPLIANCE: Passes
Maximum UA = 698
Your Home UA = 540
22.6% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.35
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 45 deg. from North; Comp. orient.: Front
Projection factor: 0.29
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 45 deg. from North; Comp. orient.: Left Side
Projection factor: 0.29
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
1894
30.0
0.0
66
326
13.0
0.0
20
41
0.640 26
38 0.400 15
513 30.0 0.0 23
36 0.640 23
Wall 3: Wood Frame, 16" o.c.
Window 3: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 45 deg. from North; Comp. orient.:
Projection factor: 0.29
Door 2: Glass
SHGC: 0.78
Bldg. faces 45 deg. from North; Comp. orient.:
Projection factor: 0.60
Wall 4: Wood Frame, 16" o.c.
Window 4: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 45 deg. from North; Comp. orient.:
Projection factor: 0.33
Floor 1: Slab -On -Grade: Unheated
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
Back
Back
Right Side
326 13.0 0.0 18
87 ' 0.640 56
18 0.580 10
513 13.0 0.0 39
41 0.640 26
209 0.0 218
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in
the RES check Inspection Checklist.
Builder/Design e ' Date �'