HomeMy WebLinkAboutRES2007-02248t�
Dec 07 07 12:37p MACIAS 9797744736 p.4
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
RCM CUSTOM HOMES
3731 DOVE CROSSING
HAS"
Percentage of T-armticide(,%) to be applied atthijs location@ 0,06%82 GAL.
T=e of E LIJ 1 l iX i 1
HorizontalliPerimeter
Beam—xx—
FounclaficIaLSIAR• l.• K
Primary Lka: RESMENCE POSITION
A LABEL FOR ANY OTHM PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMATION (IF ANY)
INCLUDING AREA COVERED, TWE PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE-
TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BYTERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONDITIONS THAT
COULD DEVELOP AS A RESULT OF THE OWNERS ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED_
Charges for pre treat:
NOTES: Annual re-newal:
SEE ATTACHED SKETCH
BUILDERS SUPPLIES SKETCHI PLAN
$319.38
$120.00
32129 PT 1011112007
.Ia
Ca orTeeWnclan SPCB 11cenee 9 =29 PT
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . . 12/07/07
Parcel Number
230100-0306-0090
Property Address
3731 DOVE CROSSING LN
COLLEGE STATION TX 77845
Subdivision Name
DOVE CROSSING PH 3
Legal Description . .
. DOVE CROSSING PH 3
LOT 9 BLK 6
Property Zoning
SINGLE FAMILY RESIDENTIAL
Owner . . . . . . . .
.
Contractor . . . . .
. K M CUSTOM HOMES
979 589-3739
Application number
07-00002248 000 000
Description of Work
RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . .
. COMBUSTIBLE (UNPROTECTED)
Occupancy type . . .
. RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . .
. / v
Approved . . . . . . .
- B16ndlfrq Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
62, 50'
SITE PLAN
SCALE: 1 "=20'-0"
PREPARED 12/OS/07, 12:01:12 INSPECTION TICKET PAGE 9
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/05/07
-------------------------------_------------------------------------------------------------------
ADDRESS 3731 DOVE CROSSING LN SUBDIV: DOVE CROSSING PH 3
CONTRACTOR K M CUSTOM HOMES T PHONE (979) 589-3739
OWNER . . PHONE
PARCEL . . 230100-0306-0090
APPL NUMBER: 07-00002248 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 10/12/07 DS BLDG, FOUNDATION -SLAB TIME: 17:00
10/12/07 AP October 12; 2007 10:25:48 AM acarter.
B115 01 11/07/07 RH BLDG, FRAMING TIME: 17:00
11/07/07 DA November 7, 2007 8:08:44 AM acarter.
11/07/2007 11:02 AM RH PDA
4 Electrical notes were not corrected from rough -in. Bond
wire for gas needs to be outside of Brick.
B115 02 11/08/07 OC BLDG, FRAMING TIME: 17:00
11/08/07 AP November 8, 2007 8:25:31 AM glsouth.
B130 01 11/09/07 RH BLDG, INSULATION TIME: 17:00
11/09/07 AP November 8, 2007 3:01:53 PM acarter.
B125 01 12/y/O) B BLDG, FINAL TIME: 17:00
6/07 1p 0 C. December 5, 2007 11:40:01 AM glsouth.
----------------------------------- CONTINUED ONTO NEXT PAGE-----------------------------------
1f p�^ , s
U
r
Date: 12/6/2007
Inspection Comments for Finals
Permit Year: 7 Permit Number: 2248
Address: 3731 DOVE CROSSING LN
Type
Inspection Type Code
Description
status
Inspection Result Comments
B115
BLDG, FRAMING
IC
11/07/2007 11:02 AM RH PDA
13115
BLDG, FRAMING
IC
Electrical notes were not corrected from rough -in. Bond
6115
BLDG, FRAMING
IC
wire for gas needs to be outside of Brick.
E110
ELEC, ROUGH IN
IC
11/05/2007 02:37 PM RH PDA
E110
ELEC, ROUGH IN
IC
Make sure light at tub has proper clearance or is suitable
E110
ELEC, ROUGH IN
IC
for wet location with proper cover. Bond gas-tite at stub
E110
ELEC, ROUGH IN
IC
out and connect w/h when installed. By framing.
M100
MECH, ROUGH IN
IC
11/07/2007 10:57 AM RH PDA
M100
MECH, ROUGH IN
IC
Return air duct has big kink from strap.
Page 1
WF0971077 / 001 City of College Station
PAGE 1
REQ. DATE: 10/03/07 i 10/03/07 15:09:43
LOCATION: 3731 DOVE CROSSING LN LOC ID: 209208
j REQUESTOR: K M CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
3/4" WTR 4" SWR
1
TASK: SET UP NEW UTILITY ACCT SETREADY
SCHED START: 10/03/07 SCHED COMPLETION: 10/03/07
JOB ORDER RESULT COMMENTS
BUILDING PERMIT
CITY OF COLLEGE STAT;ION `
1101 TEXAS AVENUE, COLLEGE STATION,,TX 77840,
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00002248 Date 10/01/07
Application pin number 655128
Property Address . . . . . . 3731 DOVE CROSSING LN
Property ID: 230100-0306-0090
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . DOVE CROSSING PH 3
Property Use . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 160000
Owner
Contractor
------------------------
------------------------
K M CUSTOM HOMES
232 SOUTHWEST PKWY
E
COLLEGE STATION
TX 77840
(979) 589-3739
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1844.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . .
BUILDING PERMIT
Additional desc
AC_
Permitpin number
527739
Permit Fee . . . .
640.00 Plan Check Fee
.00
Issue Date . . . .
10/01/07 Valuation . .
. . 160000
Expiration Date
3/29/08
Qty Unit Charge
Per
Extension
BASE FEE
460.00
60.00 3.0000
THOU BLDG, VAL 100001-500000
----------------------------
180.00
-----------------------------------------------
Special Notes and Comments
-Narrow Wall Bracing
Fully Sheathed
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLE S IN DWELLING
----------------------------------
BUILDING DEPT RE '�E�'ENT
-------------�----
E :
- ------------
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE:. (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002248
Application pin number . . . 655128
Page 2
Date 10/01/07
Special Notes and Comments
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
walls.
DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY
SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE
CORNER OF A STREET INTERSECTION. THIS MEASUREMENT
SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES
AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN
THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLAT AND HEADER
---------------------- ----- --- ----------------
BUILDING DEPT RE R/E JI T I#tE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002248
Application pin number . . . 655128
Page 3
Date 10/01/07
Special Notes and Comments
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
.OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a gl zing area that
-------- --------------- ------------------- ---- --------------
BUILDING DEPT 1 yPRE jENTAT*E�
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002248
Application pin number . . . 655128
Page 4
Date 10/01/07
Special Notes and Comments
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20o A .40 OR LOWER FACTOR AND ABOVE 20a
TO 30o A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTHjWATR HEATERS AND------------------------------�E:
------- ---------
---- --- ---- ---
BUILDING DEPT PR�FSENTP /� /
APPLICANT:
BUILDING PERMIT .
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 5
Application Number
. . . . .
07-00002248
Date 10/01/07
Application pin number
----------------------------------------------------------------------------
. . .
655128
Special Notes and
Comments
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . .
. . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid
----------
Credited
----------
Due
----------
Permit Fee Total
640.00
640.00
.00
.00
Plan Check Total
.00
.00
..00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1390.00
1390.00
.00
.00
-------------------
BUILDING DE
APPLICANT:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV
Planning fd'_Div jigit i SiivictJ.
For qfflce Use Only
DATERCC REG
'W
APPLICATION # PIT 2&40
TEMP POLE #
ADDRESS/LOCATION: �6de "h 4_)r jU'
LOT J BLOCK _ jSUBDIVISION Do/v e S 6�
BUSINESS/OWNER NAME:
G�55�
CONTRACTOR/HOMEOWNER:
CONTRACTOR ADDRESS: Z.3 Z s'W' r&k_"4Y_
�EC/PH 5 /
PHONE:
ELECTRICIAN: M& w PLUMBER: T3
HVAC: A GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOC TION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION" SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE:
HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBIL//II/TYl!,,STANDARD (TAS) PROJECT REGISTRATION# EABPRJ �p
VALUATION: $ Mo oho TOTAL AREA: 7-96 HEATED AREA: O
(Cost ofitabor and Materials)
E PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
Ft EWER TAP:
WATER TAP:
OTHER TAP:
TEMP POLE
GARAGE TYPE
NZt
JILt
JILt
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
EXTERIOR WALL TYPE
FOUNDATION TYPE
ROOF TYPE:
SINGLE UBLE TRIPLE
ATTACHED 2e__-D��Cl-!�D F] gpPJOR
2
If ►J_
51'�t
66
W
011
SIGNATURE OF APPLICANT: -"
*If proposed work involves new commercial c4quired.
structi n or facade provements/renovations to an existing
commercial property, building elevations are r
n �✓ ' ^ O � Official Use Only
Plans Examiner Zoning Official Fire Marshall
Co ments:
W(A ES))rN0
=�d-cvza,i
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
a
VA
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 0,7 _ ao2 a
DATE:
BUILDING ADDRESS:
3131 .
I. Foundation Requirements- Minimum City Foundation Standards
N
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
K
Il. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
OK
E.
Header sizes indicated on plans
NA/
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
III. Stairway Requirements
12WOK
OK
A. Stairway Details
K
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NA/
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
r
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NA/
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
NA/
Does not block any water course or divert any flow
Elevation certificate needed
&OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
LAN XAMINER DATE