HomeMy WebLinkAboutPLGS2007-02217c�
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLL='-S'I'AT I ON ,. TX 77840
PHONE: (979)764-3570 FAX:�(979)764-3496
http://bpinspdct.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00002217 Date 8/20/07
Application pin number . . . .701110
Property Address . . . . . . 361 GEORGE BUSH DR E
Property ID: - -
R #•
Application type description RESIDENTIAL, 1 UNIT ATTACHED NEW (TOWNHO
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . . TOWNHOUSE
Application valuation 128520
Owner
Contractor
- -----------
------------------------
------------
MILES CONSTRUCTION CORP.
P.O. BOX 10467
COLLEGE STATION
TX 77842
(979) 777-4675
--- Structure Information
000 000 TOWNHOME
Construction Type
COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1390.00
INTERIOR WALL TYPE
DRYWALL
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
2.00
SEWER TYPE
PUBLIC
TAZ
253.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit pin number .
520353
Permit Fee . . . .
547.00 Plan Check Fee
.00
Issue Date . . . .
8/20/07 Valuation . .
. . 128520
Expiration Date . .
2/16/08
Qty Unit Charge Per Extension
BASE FEE 460.00
29.00 3.0000 THOU BLDG, VAL 100001-500000 87.00
----------------------------------------------------------------------------
Special Notes and Comments
-Building to be fully sprinkled, plans forwarded to Fire
Dept. Marshall Eric Hurt on 7-27-07.
---------------------------
BUILDING D SENT IVE:
APPLICANT:
--- -------------------
WF0958126 / 001 City of College Station
PAGE 1
REQ. DATE: 08/21/07 08/21/07 9:10:58
LOCATION: 361 GEORGE BUSH DR E LOC ID: 209362
REQUESTOR: MILES CONSTRUCTION ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
1" WTR
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 08/21/07 SCHED COMPLETION: 08/21/07
********************************************************************************
JOB ORDER RESULT COMdENTS
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 07-00002217 Date 8/20/07
Application pin number . . . 701110
----------------------------------------------------------------------------
Special Notes and Comments
-2nd and 3rd floor operable windows must be placed 24" AFF
-All garage waterheaters must be placed on 18" platform and
no plumbing to be ran in 2 hour common wall, including pan
and T&P drains.
-Unit seperation walls are to be built to 2 hour standards
with 4' of firerated decking at roof or built to page A7.01
detail 6.
-1st floor wall design is shown 2X4@16" on center, it must
be 12" o.c. or 2X6Q16" o.c
-Make sure perimeter foundation beams are of sufficient
depth to go 12" into undisturbed soil.
-Make sur 2 hour common fire wall does not include any
plumbing or mechanical in them.
-Narrow wall bracing Fully Sheathed.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20- OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FO RESIDENTIAL .
PROPERTIES WITH FLOOR AREA GREATER T 500�1 . xo��
------------------------------- -
----------------------------
BUILDING DEk'1'tEP�2�SEN/�'ATIVE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002217
Application pin number . . . 701110
Page 3
Date 8/20/07
Special Notes and Comments
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved b low the slab, seal
annular space at ends with caulk, foaar oth me s.
BUILDING DE T--R.EPPMENJATIVE :
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002217
Application pin number . . . 701110
Page 4
Date 8/20/07
Special Notes and Comments
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20%
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2006 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page
5
Application Number . . . . . 07-00002217 Date
8/20/07
Application pin number . . . 701110
----------------------------------------------------------------------------
Special Notes and Comments
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE
ROOM.
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . WATER TAP 1" 500.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 547.00 547.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 500.00 500.00 .00
.00
Grand Total 1047.00 1047.00 .00
.00
------------------------------------------- ----`/ - -•------------
BUILDING DE�REPffSEl� TIVE
U -�
APPLICANT:
APPLICATION FOR'BUILOING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
rCITY OF COLLEGE STATION Planning & Development &micrt (979) 764-3570 (979) 764-3496 FAX
WWW CSTX GOV
For Office U�On
DATE', _ 'TRCClG
APPLICATION # Oel - as
TEMP POLE #
ADDRESS/LOCATION: 361 George Bush Drive East V NI-T 91 AIf.
LOT _2-E BLOCK A SUBDIVISION _CULPEPPER PLAZA SEC/PH
BUSINESS/OWNER NAME: Atticus Real Estate Services, Inc PHONE:972-701-9636
CONTRACTOR/HOMEOWNER: _J P Miles Construction Corporation_ PHONE: 777-4675
CONTACT PERSON FOR REVIEW COMMENTS: _Bo Miles PHONE: 777-4675
FAX: _846-7860.
EMAI L:_MILESCONSTRUCTION@GMAIL. COM
ELECTRICIAN: Matthews Electric PLUMBER: Robinson Plumbing
HVAC: Climate Masters GOOD CENTS (Residential only): No
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) x NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: Townhouse living units A townhome in Dominion on Dominik
` PROPOSED USE: Living units
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 128,520 TOTAL AREA: 1890 sf _ HEATED AREA: 1390 sf_
(Cost of Labor and Materials)
FX PUBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
E _
',EWER TAP: INTERIOR WALL TYPE: DRYWALL
SIZE
�X WATER TAP: 1
� SIZE
OTHER TAP:
TEMP POLE
GARAGE TYPE:
SIZE
SINGLE
ATTACHED
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE 5
DETACHED
BRICK
POST TENSION SLAB
COMPOSITION SHINGLES
TRIPLE
CARPORT a
SIGNATURE OF APPLICANT:
*If proposed work involves new commercial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
7--30 -07
Plans Examiner Zoning Official Fire Marshall
Comments:
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
1076
_See ResCheck attached
R1
310
X Chemical Termiticide Treatment (Soil Treatment)
Nk
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.
NOTE:
LINE AND CURVE DATA SHOWN CORRESPONDS WITH FINAL PLAT FILED BY
PLEDGERJCALKOMEY DATED JULY 1Z 2007.
LINE DATA
LINE BEARING DISTANCE
L69 N 36°02'46' E 1.07
L73 S 04"1T17' W 1.07"
CURVE DATA
CURVE RADIUS DELTA ARC TANGENT BEARING CHORD
C7 50.00' 40'21'51" 35.27 18.38' N 74*0751" W 34.50'
S 44.5606' E 29.50,
1
TP = 300.1,
TC = 301 20 I
j I v
3
LOT 2-E
0.0462 Ac. o
2013.11 SF N
ri
EXISTING
L73 SIDEWALK
NOTE: FLATWORK
EXTENDS 7 PAST
PROP. LINE.TYP.
AT ALL UNITS.
C1
A' JRI G. OGERS
�p..a.e...........60
50833��®
N O N O
�'®' GRAPHIC SCALE
LOT 2—E
Title: SITE PLANS BY LOT Scale AS SHOWN
DOMINIONS AT COLLEGE STATION Job No.
COLLEGE STATION, TX 06 0120
Drawn By DAL
ATTICLIS REAL ESTATE Checked By AGR
Gessner 1400 South Austin Street 1712 SW Pkwy. Suite 105 Drawn Date
Brenham, Texas 77834 P.O. Box 10763 College Station, Texas 77840 07/23/07
Engineering Tele: (979)836-6855 Fax: (979)836-6847 Tele: (979)680-8840 Fax: (979)680-8841 Drawing No. 5OF 10