HomeMy WebLinkAboutRES2007-02209WF0958120 / 001 City of, -col ,ge Station PAGE 1
5'
REQ. DATE: 08/21/07 M 08/21/07 9:09:32
LOCATION: 353 GEORGE BUSH DR E LOC ID: 209354
REQUESTOR: MILES CONSTRUCTION ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
1" WTR
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 08/21/07 SCHED COMPLETION: 08/21/07
********************************************************************************
JOB ORDER RESULT COMMENTS
BUILDING PERMIT
CITY OF COLLEGE STATION
1i01 TEXAS AVENUE, COLLEGE_.STATION, TX 77840
' PHONE: (979)764-3570; FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Application Number . . . . . 07-00002209 Date 8/20/07
Application pin number . . . U3909
Property Address . . . . . . 353 GEORGE BUSH DR E
Property ID: - -
R #.
Application type description RESIDENTIAL, 1 UNIT ATTACHED NEW (TOWNHO
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . . TOWNHOUSE
Application valuation . . . . 134504
Owner Contractor
------------------------ ------------------------
MILES CONSTRUCTION CORP.
P.O. BOX 10467
COLLEGE STATION TX 77842
(979) 777-4675
--- Structure Information 000 000 TOWNHOMES
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1559.00
INTERIOR WALL TYPE DRYWALL
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 2.00
SEWER TYPE PUBLIC
TAZ 253.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit pin number . 520312
Permit Fee . . . . 565.00 Plan Check Fee .00
Issue Date . . . . 8/20/07 Valuation . . . . 134504
Expiration Date . . 2/16/08
Qty Unit Charge Per Extension
BASE FEE 460.00
35.00 3.0000 THOU BLDG, VAL 100001-500000 105.00
----------------------------------------------------------------------------
Special Notes and Comments
-Building to be fully sprinkled, pla s forwarded to _Fire
Dept. Marshall Eric Hurt on 7-27-07 /J.
44,
BUILDING DE\PT REPRA&tAT E.:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1i01 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 07-00002209 Date 8/20/07
Application pin number . . . 863909
----------------------------------------------------------------------------
Special Notes and Comments
-2nd and 3rd floor operable windows must be placed 24" AFF
-All garage waterheaters must be placed on 18" platform and
no plumbing to be ran in 2 hour common wall, including pan
and T&P drains.
-Unit seperation walls are to be built to 2 hour standards
with 4' of firerated decking at roof or built to page A7.01
detail 6.
-1st floor wall design is shown 2X4@16" on center, it must
be 12" o.c. or 2X6@16"o.c.
-Make sure that perimeter foundation beams are sufficient
depth to go 12" inot undisturbed soil.
-Make sure 2 hour common fire wall does not include any
plumbing or mechanical in them.
-This is Unit B-1 and 2nd floor area to contain Simpson
Panel per plans.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
Garage ceiling must have 5/8" Type X sheetrock when there
is Habitable space above the garage.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED JFORESIDE,2ftIAI
GG
BUILDING D P EPWIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1i01 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number 07-00002209
Application pin number . . . 863909
Page 3
Date 8/20/07
Special Notes and Comments
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved elow t1je slab,_se 1
--- --------- /6.- _44044_(�_ --- - - - - - - - - - - -
BUILDING DE T EPRX4VE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002209
Application pin number . . . 863909
Page 4
Date 8/20/07
Special Notes and Comments
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20o A .40 OR LOWER FACTOR AND ABOVE 200
TO 30o A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND
PRIOR TO PLACING FILL.
VEGETATION AND FOREIGN
STAIRS SHALL COMPLY WITH
BUILDING DE
APPLICANT:
FOREIGN MATERIAL FROM SLAB AREA
FILL SHALL BE FREE FROM
MATERIAL.
SECTION R-3 (2006C��IT��2��`��
BUILDING PERMIT
CITY OF COLLEGE STATION
li01 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002209
Application pin number . . . 863909
Page 5
Date 8/20/07
Special Notes and Comments
CONTINUOUS HANDRAIL OR SECTION
1009 (2006 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC )
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
IF AN OPERABLE WINDOW IS MORE THAN 72" ABOVE EXTERIOR
FINISHED GRADE THEN THE LOWEST PART OF THE WINDOW OPENING
MUST BE AT LEAST 24" ABOVE THE FINSHED FLOOR FROM INSIDE THE
ROOM.
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND
CLOTHES DRYERS.
Other Fees WATER TAP 1"
500.00
Fee summary
Charged
----------
Paid
----------
Credited
--------------------
Due
-----------------
Permit Fee Total
565.00
565.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
500.00
500.00
.00
.00
Grand Total
1065.00
1065.00
.00
.00
------------------- ----------A- ----------- ----------------
BUILDING DE EPR T IVE:
APPLICANT:
k r
CITY OF COLLEGE STATION
Planning & Development Snvita
ADDRESS/LOCATION:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
VJWW CSTX GOV
For Olive Use Only
DATETCy
t O` R�C REG
APPLICATION #
TEMP POLE #
353 George Bush Drive East um,
LOT 2-1 BLOCK A SUBDIVISION CULPEPPER PLAZA SEC/PH
BUSINESS/OWNER NAME: Atticus Real Estate Services, Inc PHONE:972-701-9636
CONTRACTOR/HOMEOWNER: _J P Miles Construction Corporation_ PHONE: 777-4675
CONTACT PERSON FOR REVIEW COMMENTS: _Bo Miles PHONE: 777-4675
FAX: _846-7860 EMAIL:_MILESCONSTRUCTIONtC7"/ GMAIL.COM
ELECTRICIAN: Matthews Electric PLUMBER: Robinson Plumbing
HVAC: Climate Masters GOOD CENTS (Residential only): No
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) x NEW CONSTRUCTIONSLAB ONLY
DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: Townhouse living units A townhome in Dominion on Dominik
PROPOSED USE: Living units
HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
a VALUATION: $ 134,504 TOTAL AREA:1978 sf_ HEATED AREA: 1559 sf_
(Cost of Labor and Materials)
DX PUBLIC SEWER NUMBER OF BEDROOMS: 2
❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 2
SEWER TAP: INTERIOR WALL TYPE: DRYWALL
,`
SIZE
VDU � �X WATER TAP: 1 e EXTERIOR WALL TYPE: BRICK
SIZE
OTHER TAP: FOUNDATION TYPE: POST TENSION SLAB
SIZE
TEMP POLE ROOF TYPE: COMPOSITION SHINGLES
GARAGE TYPE: SINGLE DOUBLE FT] TRIPLE
ATTACH yWtCA = CARPORT
SIGNATURE OF APPLICANT: !t l Iv "LA
*If proposed work involves new com— me�rcial construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
�g 7 -30 ->,?
Plans Examiner
Zoning Official
Comments:
Fire Marshall
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
X Chemical Termiticide Treatment (Soil Treatment)
Se'e YesCheck attached
❑ Chemical Termiticide Treatment (Field Applied Wood Treatment)
❑ Physical Barriers
❑ Other
*Verification of Application shall be submitted to the City of College Station
Building Department prior to issuance of the Certificate of Occupancy.