Loading...
HomeMy WebLinkAboutCNEW2007-02203, 07-2491r, Date Permit # � a LM I Project Name COMMERCIAL CO Planning /� (Lindsay Boyer, Jennifer Prochazka, Jennifer eves, Crissy Ha] 1, Jason Schubert, Grant Wencel, Molly Hitchcock) Bridgette George Development Engineers (Alan Gibbs, Josh Norton, Carol Cotter) City Engineer (Bob Mosley, Jerry Jones, John Logan, Robert Bumpurs, William Ethridge) Environmental Services - - (Eaphrame Thomas, lames Boykin, Pete Garcia) f- d- r ..�� - r Fire Department (Eric Hurt, Eric Dotson, Jerry Duffey, SteveYi Drainage (Donnie Willis) Public Works - Sanitation (Wally Urrutia) Electrical Services (Tony Michalsky) �� Water/Wastewater Services (Joe Mike Garcia Paul Schoenfeld, Mitchell Carson) Miscellaneous Notes t5';�b' WF0974393 / 001 City of College Station PAGE 1 REQ. DATE:` ; 10/16/671 10/16/07 12:59:52 LOCATION: 3322 LONGMIRE DR LOC ID: 190984 REQUESTOR: B & A CONSTRUCTION ORIGIN: CUSTOMER -WALK IN REQ USER: KWOLFE AUTH USER:KWOLFE WRK TYPE: 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/16/07 SCHED COMPLETION: 10/16/07 ******************************************************************************** JOB ORDER RESULT COMMENTS PREPARED 6/19/08, 8:10:22 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/18/08 ------------------------------------------------------------------------------------------------ ADDRESS . : 3322 LONGMIRE DR SUBDIV: LONGMIRE PLACE CONTRACTOR B & A CONSTRUCTION PHONE (979) 846-1700 OWNER MAREK, JOE D PHONE PARCEL 391500-0000-0024 APPL NUMBER: 07-00002203 COMMERCIAL, OFFICES/BANKS/PROFESSION PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 9/17/07 DS BLDG, FOUNDATION -SLAB TIME: 17:00 9/17/07 AP September 14, 2007 9:04:40 AM kwolfe. B115 01 11/01/07 OC BLDG, FRAMING TIME: 17:00 i' 11/01/07 AE November 1, 2007 11:15:46 AM kwolfe. Window at bottom of stairs needs to be tempered by CO. B130 01 2/01/08 DS BLDG„ INSULATION TIME: 17:00 2/01/08 DP February 1, 2008 10:18:56 AM acarter. February 1, 2008 4:23:34 PM kwolfe. no insulation installed this should have went out on Monday morning, it was not recorded on the inspection request, so taking $27 off February 4, 2008 8:08:54 AM kwolfe. ';B130 02 2/04/08 DS BLDG, INSULATION TIME: 17:00 2/04/08 AP February 4, 2008 8:07:17 AM kwolfe. B125 01 5/22/08 DS BLDG, FINAL TIME: 17:00 5/22/08 DP May 22, 2008 11:54:36 AM glsouth. 05/22/2008 05:01 PM DS PDA 1 rear landing not large enough 2 steps to high 7 3/4" 7" on the other 3 ? on if it needs handicap ramp and handrails 4 no address on back door or name of bussiness 5 front and back door locked could not check inside B125 02 5/23/08 DS BLDG, FINAL TIME: 17:00 5/23/08 CA May 23, 2008 8:29:45 AM ccourt. TO GET INSIDE BUILDING CODE IS 6858. IF POSSIBLE PLEASE CALL SO HE CAN BE THERE. BRADY BRITTIAN 412-0022 05/23/2008 02:33 PM DS PDA h made it a walk through �!L B125 03 18/08 BLDG, FINAL TIME: 17:00 ( �0 June 18, 2008 2:32:19 PM acarter."� mb =f^1 k `b 6858 — Q L4F �� � co 0 or oc ox is ----------- ---------- -J-------------- COMMENTS AND NOTES-------------------------------------- (5/29/2008) Gina Southerland - Re: Fwd: Calling for C.O. @ 3322 Longmire Dr Brittain-Byers Office Bldg Pagi-101 From: Steve Smith To: Gina Southerland Date: 5/29/2008 8:07 AM i Sti.bject:- Re: Fwd: Calling for C.O. @ 3322 Longmire Dr Brittain-Byers Office Bldg They need three fire extinguishers ... OK for CO >>> Gina Southerland 05/28/08 10:16 AM >>> Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csbc.gov >>> Gina Southerland 5/22/2008 1:03 PM >>> BP# 07-2203 contact person: Brady Brittain @ 412-0022 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csbc.aov (5/28/2008) Amber Carter - Re: Calling for C.O. @ 3322 Longmire Dr Brittain-Byers Office Bldg Page 111 From: Jason Schubert To: Boyer, Lindsay; Boykin, James; Caler, Julie; Carson, Mitchell; Carte... Date: 5/27/2008 2:00 PM Subject: Re: Calling for C.O. @ 3322 Longmire Dr Brittain-Byers Office Bldg planning is ok for CO Jason >>> Gina Southerland 5/22/2008 1:03:45 pm >>> BP# 07-2203 contact person: Brady Brittain @ 412-0022 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csbc.gov (5/23/2008) Gina Southerland - Re: Calling for C.O. @ 3322 Longmire Dr Brittain-Byers Office Bldg Page 111 From: Pete Garcia To: COS Date: 5/23/2008 2:33 PM Subject: Re: Calling for C.O. @ 3322 Longmire Dr Brittain-Byers Office Bldg Attachments: Pete Garcia.vcf They are OK. 'Do not ask the Lord to Guide your Footsteps if you are not willing to move your Feet' This e-mail and/or attachment is for the sole use of the intended recipient(s) and may contain confidential and /or legally privileged information. Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all electronic and paper copies of the original message and any attachments. Thank You. >>> On 5/22/2008 at 1:03 PM, in message<48356F31.6D9C.0039.0(a)csbc.00v>, Gina Southerland wrote: BP# 07-2203 contact person: Brady Brittain @ 412-0022 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csbc.Qov (5/23/2008) Gina Southerland - Re: Calling for C.O. @ 3322 Longmire Dr Brittain-Byers Office Bldg Page 1 From: Bridgette George To: Gina Southerland Date: 5/22/2008 1:32 PM Subject: Re: Calling for C.O. @ 3322 Longmire Dr Brittain-Byers Office Bldg Do you know the property owner's name? >>> Gina Southerland 5/22/08 1:03 PM >>> BP# 07-2203 contact person: Brady Brittain @ 412-0022 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csbc.00v (5/23/2008) Gina Southerland - Re: Calling for C.O. @ 3322 Longmire Dr Brittain-Byers Office Bldg Page 1 From: To: Date: Subject: OK with Drainage. Donnie Willis Southerland, Gina 5/22/2008 3:34 PM Re: Calling for C.O. Donnie Willis, CFM Environmental Engineering Technician Certified Floodplain Manager Public Works Department 979-764-6375 office 979-229-7632 cell dwillis@cstx.gov @ 3322 Longmire Dr Brittain-Byers Office Bldg >>> On 5/22/2008 at 1:03 pm, in message<48356F31.6D9C.0039.0@cstx.gov>, Gina Southerland wrote: BP# 07-2203 contact person: Brady Brittain @ 412-0022 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csb(.gov (5/23/2 108) GinaaSoutherland - Re: Calling for C.O. @ 4809 Wayne Ct Page 1 From: Joe Garcia To: Amber Carter; Benjamin McCarty; Chris Haver; Gina Southerland; Mitch... Date: 5/23/2008 8:43 AM Subject: Re: Calling for C.O. @ 4809 Wayne Ct OK FOR CO. JMG >>> Gina Southerland 05/21/08 4:29 PM >>> BP# 07-3275 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.csbc.00v (5/2312008) Gina Southerland - Re: Calling for C.O. @ 3322 Longmire Dr Brittain-Byers Office Bldg Page II From: Bridgette George To: r Gina Southerland Date: 5/22/2008 1:32 PM Subject: Re: Calling for C.O. @ 3322 Longmire Dr Brittain-Byers Office Bldg Do you know the property owner's name? >>> Gina Southerland 5/22/08 1:03 PM >>> BP# 07-2203 contact person: Brady Brittain @ 412-0022 Gina Southerland CSR - Planning & Development Services City of College Station 979-764-3570 www.cstx.00v SPECIFICATIONS PROJECT INFORMATION: CLIENT NAME: Brady Brittain & John Byers JOB ADDRESS: 3322 Longmire Drive, College Station, TX 77845 LEGAL DESCRIPTION: Longmire Place, Lot 62D CLIENT PHONE: 979-846-1700, 979-412-0022 UTILITY INFORMATION: WATER: Rear of Lot SEWER: Rear of Lot GAS: Rear of Lot ELECTRICITY: Rear of Lot PHONE: Rear of Lot CABLE: Verify SITE WORK / LANDSCAPING: SURVEYING: EXCAVATING / CLEARING: FILL / COMPACTION: SOIL TESTS: FINISH GRADING: SPRINKLER SYSTEM LANDSCAPING: SOD: GUTTERS: FOUNDATION / FLATWORK: FOUNDATION TYPE: FINISH FLOOR ELEVATION: TERMITE TREATMENT: WATERPROOFING: REINFORCING: CONCRETE: FLATWORK: CONCRETE PUMP: MASONRY: TYPE / SIZE: MORTAR COLOR: ADDRESS BLOCK: FRAMING: EXTERIOR WALLS INTERIOR WALLS: HEADERS: CEILING JOISTS: FLOOR JOISTS: SUBFLOOR: RAFTERS: ROOF DECKING: Locate Corners as needed Clear existing grass for site work Build compacted pad per engineer's report. sidewalk nearest to front door Test select till for compaction Smooth remaining dirt around slab per Association per Association per Association 5" aluminum gutters Slab height to be even with existing Slab on grade To be even with existing sidewalk nearest front door Bora-Care treatment applied to lower portion of wood framing 6 mil. poly. See Plan 3000 PSI Connect to existing sidewalk at front entrance. Handicap ramp needed at side entrance: As necessary Red brick, to match existing buildings White, to match existing buildings Yes 2x4, Bottom plates #2 treated, all others #2 YP, SPF or equal @ 16" OC, Kool- Ply sheathing 2x4 @ 16" OC #2 YP, SPF, or equal Per local code Per local code Per local code 7/8" T&G decking 2x6 @ 16" OC 1/2" 08B Cool -Ply Page 1 of 3 a M ATTIC DECKING: To A/C unit, if applicable . ROOFING: Metal, 1" profile, concealed fasteners, to match existing buildings ROOF VENTILATION: Continuous ridge vent SOFFIT: 3/8" Hardipanel, continuous perforated FASCIA: 8" x 3/4" Hardiplank DRIP MOULD: 6" x 3/4" Hardiplank EAVE STRIP: Type DL metal edge INSULATION: WALLS: 3.5" blown cellulose - R-13 CEILINGS: 10" blown fiberglass - R-30 INTERIOR WALLS: 3.5" Batt - R-13 WINDOWS: TYPE: Aluminum, Insulating, to match existing buildings FINISH/LITE PATTERN: Match existing buildings DOORS: EXTERIOR DOORS: Glass front and side entry to match existing buildings INTERIOR DOORS: 6-panel, solid core, 1-3/8", 6'8" height DOOR HARDWARE: Lever -type door pulls, chrome finish DOOR STOPS: Hinge or Base as needed INTERIOR TRIM: WINDOW CASING: 1x4 paint grade DOOR CASING: 1x4 paint grade BASE: 1 x6 paint grade WINDOW STOOL: 1x4 paint grade CROWN: 4-1/4" in reception areas CLOSETS: MDF paint grade shelving CABINETS: Stock paint -grade cabinets in break areas FINISHES: DRYWALL: WALLS: Texture and paint CEILINGS: Texture and paint PAINT: PPG/Monarch builder grade. Colors TBD INTERIOR: Interior Walls to be one color, ceiling may be second color, trim color TBD EXTERIOR: All painted surfaces to be one color FLOOR COVERINGS: BATHROOMS: Ceramic tile ENTRY / RECEPTION: Commercial carpet HALLWAYS: Commercial carpet OFFICES: Commercial carpet WINDOW COVERINGS: ALL WINDOWS: 2" blinds MIRRORS, GLASS, TUB ENCLOSURES: MIRRORS: Bathroom Vanities to have full mirrors Page 2 of 3 ELECTRICAL: SERVICE: To be sized by electrician FIXTURES: Standard flourescent lighting, securuty lighting on exterior TV / PHONE / DATA: All rooms to be wired SMOKE DETECTORS: See Plan PLATE COLOR: White SECURITY SYSTEM: Pre -Wire MECHANICAL: NUMBER/TYPE OF UNITS: To be sized by A/C technician, zoned, 14 SEER DUCT MATERIAL: Duct board & flex duct supply lines THERMOSTAT: Programmable PLUMBING: WATER SUPPLY: Inside building to be pex piping GAS: None WATER HEATER(S): Electric Tankless water heater HOSE BIBBS: See Plan FIXTURES: 3 wall mounted sinks for baths, 3 water closets, 2 sinks for break areas APPLIANCES: None Page 3 of 3 eGenerated by COM check -Web Software l�rl Envelope Compliance Certificate 2003 IECC Report Date: 07/25/07 Section 1: Project Information Project Title: Construction Site: Owner/Agent: Section 2: General Information Building Location (for weather data): College Station, Texas Climate Zone: 4b Heating Degree Days (base 65 degrees F): 1788 Cooling Degree Days (base 65 degrees F): 2776 Project Type: New Construction Vertical Glazing / Wall Area Pct.: 19% Building Type Floor Area Unknown Building Type 2700 Section 3: Requirements Checklist Envelope PASSES: Design 32,0/9„,better than code.... Climate -Specific Requirements: Component Name/Description Roof 1: All -Wood Joist/Rafter/Truss Ext. Wall 1: Wood Frame, Any Spacing Window 1: Vinyl Frame, 2 Pane w/ Low-E, Tinted, SHGC 0.34 Door 1: Glass (over 50% glazing), Tinted, SHGC 1.05 Int. Wall 2: Wood Frame, Any Spacing Floors: Unheated Slab -On -Grade Designer/Contractor: Gross Area Cavity Cont. Proposed Budget or Perimeter R-Value R-Value U-Factor U-Factor 3258 30.0 0.0 0.035 0.063 2405 13.0 0.0 0.091 0.207 348 --- --- 0.350 1.230 112 --- --- 1.080 1.230 3186 13.0 0.0 0.089 0.339 210 --- 0.0 --- --- (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. Air Leakage, Component Certification, and Vapor Retarder Requirements: Cj 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor -permeable wrapping material installed in accordance with the manufacturer's installation instructions. ❑ 2. Windows, doors, and skylights certified as meeting leakage requirements. ❑ 3. Component R-values & U-factors labeled as certified. ❑ 4. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. Ej 5. Stair, elevator shaft vents, and other dampers integral to the building envelope are equipped with motorized dampers. El 6. Cargo doors and loading dock doors are weather sealed. ❑ 7. Recessed lighting fixtures are: (i) Type IC rated and sealed or gasketed; or (ii) installed inside an appropriate air -tight assembly with a 0.5 inch clearance from combustible materials and with 3 inches clearance from insulation material. Note: Vapor retarder not required in this location. Section 4: Compliance Statement Page 1 of 9 Compliance Statement. The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2003 IECC requirements in COMcheck-Web and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Page 2 of 9 eGenerated by COMcheck-Web Software N(l Lighting Compliance Certificate 2003 IECC Report Date: 07/25/07 Section 1: Project Information Project Title: Construction Site: Owner/Agent: Section 2: General Information Building Use Description by: Project Type: New Construction Building Type Floor Area Unknown Building Type 2700 Section 3: Requirements Checklist Interior Lighting: ❑ 1. Total actual watts must be less than or equal to total allowed watts. Allowed Watts Actual Watts Complies 2700 2559 YES ❑ 2. Exit signs 5 Watts or less per side. Exterior Lighting: 3. Efficacy greater than 45 lumens/W. Exceptions: Designer/Contractor: Specialized lighting highlighting features of historic buildings; signage; safety or security lighting; low -voltage landscape lighting. Controls, Switching, and Wiring: ❑ 4. Independent controls for each space (switch/occupancy sensor). Exceptions: Areas designated as security or emergency areas that must be continuously illuminated. Lighting in stairways or corridors that are elements of the means of egress. 5. Master switch at entry to hotel/motel guest room. 6. Individual dwelling units separately metered. 7. Each space provided with a manual control to provide uniform light reduction by at least 50%. Exceptions: Only one luminaire in space; An occupant -sensing device controls the area; The area is a corridor, storeroom, restroom, public lobby or guest room; Areas that use less than 0.6 Watts/sq.ft. 8. Automatic lighting shutoff control in buildings larger than 5,000 sq.ff. Cl 9. Photocell/astronomical time switch on exterior lights. Exceptions: Lighting intended for 24 hour use. Page 3 of 9 10.Tandem wired one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts). Exceptions: Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 4: Compliance Statement Compliance Statement. The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2003 IECC, Chapter 8, requirements in COMcheck-Web and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Page 4 of 9 N( Generated by COMcheck-Web Software Lighting Application Worksheet 20031ECC Report Date: Section 1: Allowed Lighting Power Calculation A B C D Floor Area Allowed Allowed Watts Watts / ft2 Unknown Building Type 2700 1 2700 Total Allowed Wafts = 2700 Section 2: Actual Lighting Power Calculation A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Incandescent 1: 60W Inc for offices 3 13 60 780 Incandescent 2: 60W WC Lights 3 3 60 180 Incandescent 3: 75W Misc Spots 1 5 75 375 Incandescent 4: 100W Ext Entrances 1 4 100 400 Incandescent 5: 150W Ext Flood 2 4 . 150 600 Linear Fluorescent 1: 48 in. T8 30W (Super T8) / Hybrid 2 7 32 224 Total Actual Wafts = 2559 Section 3: Compliance Calculation If the Total Allowed Wafts minus the Total Actual Wafts is greater than or equal to zero, the building complies. Total Allowed Wafts = 2700 Total Actual Wafts = 2559 Project Compliance = 141 Lighting PASSES: Design 5% better than code. Page 5 of 9 Generated by COM check -Web Software Mechanical Compliance Certificate 2003 I ECC Report Date: 07/25/07 Section 1: Project Information Project Title: Construction Site: Owner/Agent: Section 2: General Information Building Location (for weather data): College Station, Texas Climate Zone: 4b Heating Degree Days (base 65 degrees F): 1788 Cooling Degree Days (base 65 degrees F): 2776 Project Type: New Construction Section 3: Mechanical Systems List Designer/Contractor: uanti System Type & Description 1 A Unit: Heating: Central Furnace, Electric / Cooling: Split System, Capacity <65 kBtu/h, Evaporatively Cooled Condenser / Single Zone 1 BC Unit: Heating: Central Furnace, Electric / Cooling: Split System, Capacity <65 kBtu/h, Evaporatively Cooled Condenser / Single Zone 1 Water Heater 1: Service Water Heater Section 4: Requirements Checklist Requirements Specific To: A Unit: ❑ 1. Equipment minimum efficiency: Split System: 12.1 EER Requirements Specific To: BC Unit: ❑ 1. Equipment minimum efficiency: Split System: 12.1 EER Requirements Specific To: Water Heater 1 ❑ 1. Heat traps in inlet/outlet fittings ❑ 2. 1/2-in. insulation on 8 ff of inletloutlet piping if no'integral heat traps Cl 3. Unknown hot water system type. Efficiency requirements can not be determined. Generic Requirements: Must be met by all systems to which the requirement is applicable: ❑ 1. Load calculations per 2001 ASHRAE Fundamentals 2. Plant equipment and system capacity no greater than needed to meet loads - Exception: Standby equipment automatically off when primary system is operating Exception: Multiple units controlled to sequence operation as a function of load 3. Minimum one temperature control device per system 4. Minimum one humidity control device per installed humidification/dehumidification system 5. Thermostatic controls has 5 degrees F deadband - Exception: Thermostats requiring manual changeover between heating and cooling ❑ 6. Automatic Controls: Setback to 55 degrees F (heat) and 85 degrees F (cool); 7-day clock, 2-hour occupant override, 10-hour backup Page 6 of 9 - Exception: Continuously operating zones - Exception: 2 kW demand or less, submit calculations 7. Automatic shut-off dampers on exhaust systems and supply systems with airflow >3,000 cfm 8. Outside -air source for ventilation; system capable of reducing OSA to required minimum 9. R-5 supply and return air duct insulation in unconditioned spaces R-8 supply and return air duct insulation outside the building R-8 insulation between ducts and the building exterior when ducts are part of a building assembly - Exception: Ducts located within equipment - Exception: Ducts with interior and exterior temperature difference not exceeding 15 degrees F. ❑ 10.Ducts sealed -longitudinal seams on rigid ducts; transverse seams on all ducts; UL 181A or 181 B tapes and mastics - Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at static pressures less than 2 inches w.g. pressure classification Cl 11. Mechanical fasteners and sealants used to connect ducts and air distribution equipment Cj 12. Hot water pipe insulation: 1 in. for pipes <=1.5 in. and 2 in. for pipes >1.5 in. Chilled water/refrigerant/brine pipe insulation: 1 in. for pipes <=1.5 in. and 1.5 in. for pipes >1.5 in. Steam pipe insulation: 1.5 in. for pipes <=1.5 in. and 3 in. for pipes >1.5 in. Exception: Piping within HVAC equipment Exception: Fluid temperatures between 55 and 105 degrees F Exception: Fluid not heated or cooled Exception: Runouts <4 ft in length ❑ 13.Operation and maintenance manual provided to building owner ❑ 14.Balancing devices provided in accordance with IMC 603.15 ❑ 15.Newly purchased service water heating equipment meets the efficiency requirements 16. Water heater temperature controls: 110 degrees F for dwelling units or 90 degrees F for other occupancies o 17.Stair and elevator shaft vents are equipped with motorized dampers Section 5: Compliance Statement Compliance Statement. The proposed mechanical design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2003 IECC requirements in COMcheck-Web and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Page 7 of 9 Generated by COMcheck-Web Software Mechanical Requirements Description 2003 IECC Report Date: The following list provides more detailed descriptions of the requirements in Section 4 of the Mechanical Compliance Certificate. Requirements Specific To: A Unit: 1. The specified heating and/or cooling equipment is covered by ASHRAE 90.1 Code and must meet the following minimum efficiency: Split System: 12.1 EER Requirements Specific To: BC Unit: 1. The specified heating and/or cooling equipment is covered by ASHRAE 90.1 Code and must meet the following minimum efficiency: Split System: 12.1 EER Requirements Specific To: Water Heater 1 1. Heat traps are required on noncirculating water heating systems on both inlet and outlet connections. Heat traps may be purchased or field -fabricated by creating a loop or inverted U-shaped arrangement on the inlet and outlet pipes. 2. Pipe insulation for the specified noncirculating service hot water system is required for all piping in the following categories:a) the first 8 ft of outlet piping from any constant -temperature, noncirculating storage systemb) the inlet piping between the storage tank and a heat trap in a noncirculating storage systemPipe insulation must be at least 1/2 in. and have a conductivity no >0.28 Btu-in/(h-ft2-degrees F). 3. Service water heating equipment used solely for heating potable water, pool heaters, and hot water storage tanks must meet the following miniumum efficiency: Unknown hot water system type. Efficiency requirements can not be determined. Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. Design heating and cooling loads for the building must be determined using procedures in the ASHRAE Handbook of Fundamentals or an approved equivalent calculation procedure. 2. All equipment and systems must be sized to be no greater than needed to meet calculated loads. A single piece of equipment providing both heating and cooling must satisfy this provision for one function with the capacity for the other function as small as possible, within available equipment options. Exception: The equipment and/or system capacity may be greater than calculated loads for standby purposes. Standby equipment must be automatically controlled to be off when the primary equipment and/or system is operating. Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated load are allowed if they are provided with controls to sequence operation of the units as the load increases or decreases. 3. Each heating or cooling system serving a single zone must have its own temperature control device. 4. Each humidification system must have its own humidity control device. 5. Thermostats controlling both heating and cooling must be capable of maintaining a 5 degrees F deadband (a range of temperature where no heating or cooling is provided). - Exception: Deadband capability is not required if the thermostat does not have automatic changeover capability between heating and cooling. 6. The system or zone control must be a programmable thermostat or other automatic control meeting the following criteria:a) capable of setting back temperature to 55 degrees F during heating and setting up to 85 degrees F during coolingb) capable of automatically setting back or shutting down systems during unoccupied hours using 7 different day schedulesc) have an accessible 2-hour occupant overrided) have a battery back-up capable of maintaining programmed settings for at least 10 hours without power. - Exception: A setback or shutoff control is not required on thermostats that control systems serving areas that operate continuously. - Exception: A setback or shutoff control is not required on systems with total energy demand of 2 kW (6,826 Btu/h) or less. 7. Outdoor -air supply systems with design airflow rates >3,000 cfm of outdoor air and all exhaust systems must have dampers that are automatically closed while the equipment is not operating. 8. The system must supply outside ventilation air as required by Chapter 4 of the International Mechanical Code. If the ventilation system is designed to supply outdoor -air quantities exceeding minimum required levels, the system must be capable of reducing outdoor -air flow to the minimum required levels. Page 8 of 9 9. Air ducts must be insulated to the following levels:a) Supply and return air ducts for conditioned air located in unconditioned spaces (spaces neither heated nor cooled) must be insulated with a minimum of R-5. Unconditioned spaces include attics, crawl spaces, unheated basements, and unheated garages.b) Supply and return air ducts and plenums must be insulated to a minimum of R-8 when located outside the building.c) When ducts are located within exterior components (e.g., floors or roofs), minimum R-8 insulation is required only between the duct and the building exterior. Exception: Duct insulation is not required on ducts located within equipment. Exception: Duct insulation is not required when the design temperature difference between the interior and exterior of the duct or plenum does not exceed 15 degrees F. 10. All joints, longitudinal and transverse seams, and connections in ductwork must be securely sealed using weldments; mechanical fasteners with seals, gaskets, or mastics; mesh and mastic sealing systems; or tapes. Tapes and mastics must be listed and labeled in accordance with UL 181A or UL 181 B. - Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at static pressures less than 2 inches w.g. pressure classification. 11. Mechanical fasteners and seals, mastics, or gaskets must be used when connecting ducts to fans and other air distribution equipment, including multiple -zone terminal units. 12. All pipes serving space -conditioning systems must be insulated as follows: Hot water piping for heating systems: 1 in. for pipes <=1 1/2-in. nominal diameter 2 in. for pipes >1 1/2-in. nominal diameter. Chilled water, refrigerant, and brine piping systems: 1 in. insulation for pipes <=1 1/2-in. nominal diameter 1 1/2 in. insulation for pipes >1 1/2-in. nominal diameter. Steam piping: 1 1/2 in. insulation for pipes <=1 1/2-in. nominal diameter 3 in. insulation for pipes >1 1/2-in. nominal diameter. Exception: Pipe insulation is not required for factory -installed piping within HVAC equipment. Exception: Pipe insulation is not required for piping that conveys fluids having a design operating temperature range between 55 .degrees F and 105 degrees F. Exception: Pipe insulation is not required for piping that conveys fluids that have not been heated or cooled through the use of fossil fuels or electric power. Exception: Pipe insulation is not required for runout piping not exceeding 4 ft in length and 1 in. in diameter between the control valve and HVAC coil. 13. Operation and maintenance documentation must be provided to the owner that includes at least the following information:a) equipment capacity (input and output) and required maintenance actionsb) equipment operation and maintenance manualsc) HVAC system control maintenance and calibration information, including wiring diagrams, schematics, and control sequence descriptions; desired or field -determined set points must be permanently recorded on control drawings, at control devices, or, for digital control systems, in programming commentsd) complete narrative of how each system is intended to operate. 14. Each supply air outlet or diffuser and each zone terminal device (such as VAV or mixing box) must have its own balancing device. Acceptable balancing devices include adjustable dampers located within the ductwork, terminal devices, and supply air diffusers. 15. Service water heating equipment must meet minimum Federal efficiency requirements included in the National Appliance Energy Conservation Act and the Energy Policy Act of 1992, which meet or exceed ASHRAE 90.1 Code. New service water heating equipment can be assumed to meet these requirements. 16. Water -heating equipment must be provided with controls that allow the user to set the water temperature to 110 degrees F for dwelling units and 90 degrees F for other occupancies. Controls must limit output temperatures of lavatories in public facility restrooms to 110 degrees F. 17. Stair and elevator shaft vents must be equipped with motorized dampers capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. All gravity outdoor air supply and exhaust hoods, vents, and ventilators must be equipped with motorized dampers that will automatically shut when the spaces served are not in use. Exceptions: - Gravity (non -motorized) dampers are acceptable in buildings less than three stories in height above grade. - Ventilation systems serving unconditioned spaces. Page 9 of 9 `� City of College Station Page of 'AV Building Inspection Department g PLANS EXAMINATION REPORT Address: 332-2 Date: 7/31/07 Project Name: ✓.5�,e,'1� �a ►3'^'Io/'Ky Drawing Number Code Ref. Number Questions or Comments S-fa,�,•w 60"" L�ea..eNtG �� /�C 00✓+ r . e Received by: Date: P� njamin McCa - 3322 Longmire building permit Page 1 From: Jason Schubert To: McCarty, Benjamin Date: 8/9/2007 10:31:13 AM Subject: 3322 Longmire building permit Ben, I have reviewed the above referenced revised building permit and have no further comments. Jason Jason Schubert Staff Planner Planning & Development Services City of College Station Phone: 979.764.3570 Fax: 979.764.3496 Benjamin McCarty - 3322 Longmire building elevations Page 1 From: Jason Schubert To: Brittain, Brady Date: 7/5/2007 10:12:46 AM Subject: 3322 Longmire building elevations Brady, I have received the revised building elevations for this project. They have been approved. The next step is to apply for a building permit, which would include the revised elevations in the submittal. Let me know if you have any questions. Jason Jason Schubert Staff Planner Planning & Development Services City of College Station Phone: 979.764.3570 Fax: 979.764.3496 CC: McCarty, Benjamin Edit Narrativ® SUNGARWPUBUC SECTOR NoviUne p S .. M D Ei I SpeN dick % i ttn 5 j Appkeflon monDer,type: 07 00002203 COMMERCM, OFFICESIBANKSMR Property address: 3322 LONOMIRE OR needs handrail on wall aide of new handicap ramp one toilet seat did not get changed to open front type a 9 v 0 &UIL6WNG• PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Application Number . . . . . 07-00002203 Date 8/16/07 Application pin number . . . 192506 Property Address . . . . . . 3322 LONGMIRE DR Property ID: 391500-0000-0024 R #: R103928 Application type description COMMERCIAL, OFFICES/BANKS/PROFESSION Subdivision Name . . . . . . LONGMIRE PLACE Property Use . . . . . . . . BUSINESS Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 180000 Owner Contractor ------------------------ ------------------------ MAREK, JOE D B & A CONSTRUCTION 1300 ANNA ST 4103 S TEXAS # 219 COLLEGE STATION TX 778403109 BRYAN TX 77802 (979) 846-1700 --- Structure Information 000 000 NEW OFFICE BUILDING Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . BUSINESS Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N/A FOUNDATION TYPE SLAB HEATED AREA 2700.00 INTERIOR WALL TYPE SHEETROCK SEWER TYPE PUBLIC TAZ 383.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit pin number . 519744 Permit Fee . . . . 700.00 Plan Check Fee .00 Issue Date . . . . 8/16/07 Valuation . . . . 180000 Expiration Date 2/12/08 Qty Unit Charge Per Extension BASE FEE 460.00 80.00 3.0000 THOU BLDG, VAL 100001-500000 240.00 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ADDRESS ON COMMERCIAL BUILDINGS -FRONT: 5" ADDRESS NUMBERS, AND ON REAR DOOR(S): 2" HIGH ADDRESS NUMBERS AND NAME OF BUSINESS. PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS PASSAGEWAY MAY HAVE TO BE ELEVATED TO ALLOW FOR REQUIRED R-VALUE ATTIC INSULATION. ------------------- BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 07-00002203 Date 8/16/07 Application pin number . . . 192506 ---------------------------------------------------------------------------- Special Notes and Comments Permit Number provided by the COOS shall be conspicuously posted in the lower right hand corner of the banner. Shall be mounted parallel to the face of a building or permanent structure. Shall advertise only the name of, uses of, or goods or services available within the building or tenant lease space to which the banner is attached. Shall not be located within public road ROW (State or Local) . Shall not obstruct any window, door, stairway, or other opening inteded for ingress or for needed ventilation or light. Shall not exceed the top of the structure to which it is attached. Shall advertise only the name of, uses of, or goods or services available within the building, or tenant lease space, to which the banner is attached. Shall be mounted parallel to the face of the building. Shall not be cantilevered away from the structure. Shall not extend more than one foot from any exterior building face, mansard, awning, or canopy. Shall not obstruct any window, door, stairway, or other opening intended for ingress or for needed ventilation or light. Shall not be attached to any tree, fence, or public utility pole. ELECTRICAL UTILITIES COMMENTS DEVELOPER INSTALLS CONDUIT PER CITY SPECS & DESIGN DEVELOPER PROVIDES TEMP BLANKET EASEMENT FOR CONSTRUCTION DEVELOPER POURS TRANSFORMER PAD PER CITY SPECS (IF NECESSARY) DEVELOPER PROVIDES 30' RIGID CONUDIT FOR RISER POLE (IF NECESSARY) DEVELOPER INSTALLS FIRST 10' OF CONDUIT ON RISER POLE. CITY INSTALLS REMAINING 201. DEVELOPER PROVIDES EASEMENTS FOR ELECTRIC INFRASTRUCTURE AS INSTALLED FOR ELECTRIC LINES. DEVELOPER PROVIDES DIGITAL SITE PLAN IN AUTOCADE 14 VERSION. EMAIL TO RBOLIN@CI.COLLEGE-STATION.TX.US DEVELOPER IS REPSONSIBLE FOR THE INSTALLATION OF SERVICE FROM TRANSFORMER TO BUILDING ------------------------------------ ----------------- BUILDING DEPT REPRESENTATIVE: ---ti=.�`'I/ APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002203 Application pin number . . . 192506 Page 3 Date 8/16/07 Special Notes and Comments FOR QUESTIONS CONTACT RONNIE BOLIN AT 979-764-3614 PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE PROVIDE COMBUSTION AIR: FOR GAS -FIRED APPLIANCES PER SECTION 304 OF THE 2006 INTERNATIONAL FUEL GAS CODE; FOR OTHER FUELS TO COMPLY WITH CHAPTER 7 OF THE 2006 IMC. Underground electrical conduit installation shall be installed per city specs and is the responsibility of the owner and/or contractor. Contact the electrical division at (979) 764-6314 for more information. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR REQUIRED EXIT DOOR(S) PROVIDE FIRE EXTINGUISHERS) - VERIFY LOCATION AND PLACEMENT WITH THE FIRE MARSHALL'S OFFICE (MIN. 2A10BC) GUARDS SHALL COMPLY WITH SECTION 1013 OF THE 2006 IBC. Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROVIDE MINIMUM 42" CLEARANCE FROM CENTER LINE OF WATER CLOSET TO EDGE OF LAVATORY OR WALL TO COMPLY WITH ANSI 2003, ACCESSIBLE STANDARDS. HANDRAILS SHALL COMPLY WITH SECTION R-311 (2003 IRC) OR SECTION 1009 (2003 IBC) AS APPROPRIATE PROVIDE A KNOX BOX FOR FIRE DEPARTMENT ACCESS. A KEY FOR EACH SHELL BUILDING AND/ OR TENANT DOOR IS REQUIRED. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT INTERIOR LIGHTING SHALL MEET THE CONTROLS AND WATTAGE --------------------------- - - --- -- --------------- BUILDING DEPT REP$ESENTATIVE: _ APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 07-00002203 Date 8/16/07 Application pin number . . . 192506 ---------------------------------------------------------------------------- Special Notes and Comments REQUIREMENTS OF SECTION 505 OF THE 2006 INTERNATIONAL ENERGY CONSERVATION CODE. All roof and ground -mounted mechanical equipment shall be sreened from view or isolated so as not to be visible from any public right-of-way or residential district within 150 feet of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. Acceptable methods of screening rooftop equipment may include, but are not limited to encasement, parapet walls, or partition screens. A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) PROVIDE PANIC HARDWARE ON EXIT DOORS If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE Permit shall be posted on the storage container. POST PERMIT CARD ON JOB SITE PROJECTIONS (OVERHANGS) BEYOND THE EXTERIOR WALL SHALL COMPLY WITH ORDINANCE NO. 2713 AND CHAPTER 12 AMENDMENTS TO THE U.D.O. AND EXHIBITS "A", "B", AND "C". WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTO OR LOWER SHALL BE MET. AS PER THE ZONING ORDINANCE SECTION 12.3.L; ATTACHED SIGNS SHALL NOT EXTEND MORE THAN ONE FOOT AWAY FROM EXTERIOR BUILDING FACE ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE -------------------------------------------- - - ---------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 07-00002203 Date 8/16/07 Application pin number . . . 192506 ---------------------------------------------------------------------------- Special Notes and Comments TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. CONSTRUCTION CONTRACTS OVER $50,000 REQUIRE SUBMISSION TO THE STATE FOR ACCESSIBILITY REVIEW - CONTACT TDLR @ (512) 463-3211 FOR MORE INFORMATION TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC ) ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK PROVIDE OSB SHEATHING FOR SHEAR WALL BRACING, SEE NOTES ON BUILDING PLANS. PROVIDE EMERGENCY LIGHTING,SEE NOTES AND LOCATIONS ON BUILDING PLANS. PROVIDE HANDRAIL EXTENSIONS AT STAIRS PER 2006 IBC. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ---------------------------------------- ----------------- Permit Fee Total 700.00 700.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1450.00 1450.00 .00 .00 ------------------------------- - ------------------------- BUILDING DEPT REPr7TATIVE: — APPLICANT: TEMPIJRARY• POLE PERMIT CITY OF COLLEGE STATION 1101'TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00002491 Date 8/16/07 Application pin number . . . 588168 Property Address . . . . . . 3322 LONGMIRE DR Property ID: 391500-0000-0024 R #: R103928 Application type description TEMP POLE Subdivision Name . . . . . . LONGMIRE PLACE Property Use . . . . . . . . BUSINESS Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 0 Owner Contractor ------------------------ MAREK, JOE D ------------------------ B & A CONSTRUCTION 1300 ANNA ST 4103 S TEXAS # 219 COLLEGE STATION TX 778403109 BRYAN TX 77802 (979) 846-1700 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit pin number . 519751 Permit Fee . . . . 20.00 Issue Date . . . . 8/16/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------------------------------------------- BUILDING DEPT REPREOENTATIVE: APPLICANT: 1111*1. //"" ,',.CITY OF COLLEGE STATION PLvmmS cb Dnrlapwmi Sera cet DATE: — ' 10" TRCCREG -_ APPLICATION # / —v TEMP POLE # I -C --�� l ADDRESS/LOCATION: 3322 LONGMIRE DRIVE, COLLEGE STATION, TX 77845 LOT 132D BLOCK - SUBDIVISION LONGMIRE PLACE SEC/PH - BUSINESS/OWNER NAME: BRADY BRITTAIN & JOHN BYERS PHONE: 979-412-0022 CONTRACTOR/HOMEOWNER: B&A CONSTRUCTION PHONE: 979-412-0022 CONTACT PERSON FOR REVIEW COMMENTS: BRADY BRITTAIN PHONE: 979-412-0022 FAX: 979-846-6863 EMAIL: BRADY@ASSISTBCS.COM ELECTRICIAN: LINK AT THIS TIME PLUMBER: JIB PLUMBING HVAC: JONES HEATING & AIR GOOD CENTS (Residential only): ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION ' SLAB ONLY DUPLEX (Landscape Plans) REMODEURENOVATION' SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: NEW CONSTRUCTION -SITE PREP TO 100% COMPLETION PROPOSED USE: PROFESSIONAL OFFICE BUILDING HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: APPROVED TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ A7820230 W1,00 VALUATION: $ 180,000 TOTAL AREA: 3470 HEATED AREA: 2700 (Cost of Labor and M_ atedals) 7X PUBLIC•SEWER NUMBER OF BEDROOMS: N/A Q SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: N/A 'P SEWER TAP: 4" INTERIOR WALL TYPE: 2X4 WOOD STUD N" SIZE O° QX WATER TAP. 3/4" EXTERIOR WALL TYPE: 2X4 WOOD STUD (��• SIZE OTHER TAP: FOUNDATIONTYPE: O SIZE TEMP POLE ROOF TYPE: `-� JC V GARAGE TYPE: SINGLE DOUBLE TRIPLE' ATTACHED D CARPORT 1 6(13 3 N - 0 TACHED 0 APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX77840 (979) 764-3570 (979) 764-3496 FAX YWVW.CSTX.GOV SIGNATURE OF APPLICANT: *If proposed work involves new comm -con struc tion-or4aeadei ovements/renovations to an existing commercial property, building elevatio are required. Official Use Only a� e'z s Plans Examiner Zoning Official Fire Marshall 9ents: T NO Energy Code Compliance Information % Glazing of exterior walls Insulation R value of 'exterior walls Insulation. R value of ceiling. I (flat areas) Insulation.R value, of ceiling 2 (vaulted.areas/no attic). Glazing. SHGC. (Solar Heat Gain Coefficient) Glazing U-Factor R value of ductwork 19.54% R-13 R-30 R-19 0.34 .35 R-6 A/C SEER Rating 14-SEER Protection Against Subterranean Termites ❑ Chemical Termiticide Treatment (Soil Treatment) E Chemical. Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical Barriers Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy-