INSPECTION TICKET PAGE 3
City of
----------------------.--------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR DATE 12/08/08
ADDRESS
. : 2453 NEWARK CIR
SUBDIV:
CONTRACTOR CLASSIC CENTURY HOMES PHONE (817) 561-4369
OWNER
GREENS PRAIRIE INVESTORS LTD PHONE
PARCEL
184200-2501-0230
APPL NUMBER: 07-00002193 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
11/05/07 OC
BLDG, FOUNDATION -SLAB TIME: 17:00
11/05/07 AP
November 5, 2007 10:24:54 AM kwolfe.
Strings On Setbacks O.K.
Slab Ground Installed
B120 01
11/13/07 RH
BLDG, FRAMING -PARTIAL TIME: 17:00
11/13/07 AE
November 13, 2007 8:32:29 AM kwolfe.
APA FRAMING
11/13/2007 04:06 PM RH PDA
Install base anchor brackets at garage. By framing.
B115 01
12/20/07 RH
BLDG, FRAMING TIME: 17:00
12/20/07 DP
December 20, 2007 11:59:09 AM glsouth.
December 20, 2007 4:41:45 PM kwolfe.
fireblocking for fireplace
joist hangers
-
need doors installed properly
tape seal holes & seams
B115 02
12/28/07 OC
BLDG, FRAMING TIME: 17:00
12/28/07 AP
December 28, 2007 9:04:19 AM kwolfe.
B130 01
1/02/08 RH
BLDG, INSULATION TIME: 17:00
1/02/08 AP
January 2, 2008 8:56:16 AM acarter.
B125 01
12/08/08 111 p�
BLDG, FINAL TIME: 17:00
4!✓
December 8, 2008 10:54:33 AM ccourt.
-------------------------------- ---- COMMENTS AND NOTES -------------------
I
Ci1 PvSe
1
d- raaj You +kaea.
1%
WF0950000 / 001 City of College Station
'r
PAGE 1
REQ. DATE: 08/10/07 08/10/07 8:17:14
LOCATION: 2453 NEWARK CIR LOC ID: 203994
REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN
REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE:
SWR 4" WTR 3/4"
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 08/10/07 SCHED COMPLETION: 08/10/07
********************************************************************************
JOB ORDER RESULT CON14ENTTS
TEXAS SPCB TERMITE TREATMENT DISCLOSURE DOCUMENT
Propedy Ownerl CLASSIC CENTURY HOMES �^ , (q�
Location to be Treated: 2453 NEWARK
Approximate Measures to be lreat.ed:
3324
lRercentage of m• to • - applied at this! I .
Foundation: SLAB Sidina: BRICK
Primary- RESIDENCE i •• •mposlilm
labelof - r fm- inaecticide has been attagzhed as part of document.
A LABEL FOR ANY OTHER PESTICIDE RECOMENDED OR USED HAS BEEN ATTACHED AS PART OF THIS DOCUMENT. WARRANTY INFORMAT►ON (IF ANY)
INCLUDING AREA COVERED, TIME PERIOD OF WARRANTY, RENEWAL OPTIONSAND COST, THE OBLIGATIONS OF THE PEST CONTROL OPERATOR TO RE-
TREAT FOR TERMITE INFESTATIONS OR REPAIR DAMAGE CAUSED BY TERMITE INFESTATIONS WITHIN THE WARRANTY PERIOD, AND THE CONOrrIONS THAT
COULD DEVELOP AS A RESULT OF THE OWNERS ACTION OR INACTION THAT WOULD VOID THE WARRANTY HAS ALSO BEEN ATTACHED.
Charges for pretreat
NOTES: Annual re-newal:
SEE ATTACHED SKETCH
BUILDERS SUPPLIES SKETCH! PLAN
$369.82
$'130.00
32129 PT 10/3112007
Ca or TeeItInci n SPCS Oomse H 32129 PT
t,-d £Z8£ 069 6L6 SO/8 - 400 139£: l l 60 Z 6 ref
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840°
P�IONE: (979) 764-3570 FAX: (979) 764-3496 -w_- ==-'
http://bpinspect.cstx.gov
--------------------- ------------------------------------------------------
Application Number . . . . . 07-00002193 Date 8/07/07
Application pin number . . . 745011
Property Address 2453 NEWARK CIR
Property ID: 184200-2501-0230
R #: R303661
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . CASTLEGATE PH 5 SEC 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL DISTRICT
Application valuation . . . . 177408
Owner Contractor
------------------------ ------------------------
GREENS PRAIRIE INVESTORS LTD CLASSIC CENTURY HOMES
4490 CASTLEGATE DR 5001 HWY 287 S
COLLEGE STATION TX 778453388 ARLINTON TEXAS
ARLINGTON TX 76017
(817) 561-4369
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2688.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 441.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit pin number . 517433
Permit Fee . . . . 694.00 Plan Check Fee .00
Issue Date . . . . 8/07/07 Valuation . . . . 177408
Expiration Date . . 2/03/08
Qty Unit Charge Per Extension
BASE FEE 460.00
78.00 3.0000 THOU BLDG, VAL 100001-500000 234.00
----------------------------------------------------------------------------
Special Notes and Comments
-Engineered Foundation and Framing.
------------------------- ---- - - ----------- ----------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496,
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 07-00002193 Date 8/07/07
Application pin number . . . 745011
---------------------=------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
BORACARE TREATMENT IS A SUITABLE SUBSTITUTE.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED
IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE
ISSUED.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE
Surface Drainage Shall Be Diverted to an Approved Point of
Collection. Lots Shall Have a Grade Fall Minimum of 6"
inches Within the First 10' feet Away From the Foundation
Walls.
DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY
SHALL BE CONSTRUCTED WITHIN TWENTY FEET (201) OF THE
CORNER OF A STREET INTERSECTION. THIS MEASUREMENT
SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES
AT THE CORNER." ALSO NOTHING SHALL BE CONSTRUCTED IN
THIS TRIANGLE TO IMPAIR VEHICLE DRIVERS VISION.
ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8"
side & 16" front) For Openings >6 sq. ft. (12" side & 20"
front)
ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DO HEADE -
BUILDING DEPT REPRESENTATIVE:.
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS -AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
http://bpinspect.cstx.gov
Application Number . . . . . 07-00002193
Application pin number . . . 745011
Page 3
Date 8/07/07
Special Notes and Comments
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
ACCESS TO JACUZZI TUB CIRCULATION PUMPS SHALL BE PROVIDED IN
ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING
CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A
MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM
ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING
IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
A Minimum of No. 15 Asphalt Felt or Other Approved Water
Resisitive Barrier Shall be Placed Over All Exterior
Sheathing Per 2006 IRC Section R703.2
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2006 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
Also assure proper protection of pipe to U.V. light.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT PAIR LEZ-.-
GE
------------------------------------------L'.c---------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS -AVENUE, COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496, `
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 07-00002193 Date 8/07/07
Application pin number . . . 745011
----------------------------------------------------------------------------
Special Notes and Comments
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO
GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20%
TO 30% A .35 FACTO OR LOWER SHALL BE MET.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOU CE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18 OVE E F OR�I
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS•AVENUE, COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496 ,
http://bpinspect.cstx.gov
----------------------------------------------------------------------------
Page 5
Application Number
. . . . .
07-00002193
Date 8/07/07
Application pin number
----------------------------------------------------------------------------
. . .
745011
Special Notes and
Comments
PRIVATE GARAGES.
THIS INCLUDES
BOTH WATER
HEATERS AND
CLOTHES DRYERS.
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid
----------
Credited
----------
Due
----------
-----------------
Permit Fee Total
694.00
694.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1444.00
1444.00
.00
.00
6v• -
------------------------------------------ j-4-4-- ua ----------------------------
BUILDING DEPT REPRESENTATIVE: __—
APPLICANT:
TEMPORARY POLE PERMIT
�. CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840 '
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
07-00002194
Date 8/07/07
Application pin number . . .
859170
Property Address . . . . . .
2453 NEWARK CIR
Property ID:
184200-2501-0230
R #:
R303661
Application type description
TEMP POLE
Subdivision Name . . . . . .
CASTLEGATE PH 5 SEC 2
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
PLANNED DEVL DISTRICT
Application valuation . . . .
0
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS LTD
------------------------
CLASSIC CENTURY
HOMES
4490 CASTLEGATE DR
5001 HWY 287 S
COLLEGE STATION TX 778453388
ARLINTON TEXAS
ARLINGTON
TX 76017
(817) 561-4369
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc GS
Permit pin number 517441
Permit Fee . . . . 20.00
Issue Date . . . . 8/07/07
Valuation . .
. . 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary Charged
----------
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
-
APPLICANT:
Jun 20 07 02:04p Uch - B/cs
y /y byU ;562:9 p.[
"r
Carr OF `�R?G��S�AT3otJ
ADDRESS/LOCATION:
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77040
(979) 764-3570 (070) 784-3490 FAX
WWW.CSTX.GOV
For to Uw Orly
OATE� C RE/G/�
APPLICATI DNA
TEMP POLE 0 �'
LOT 2 3 BLOCK 1 SUBDIVISION -(2(JS'rLC- A re:- ✓ SECJPH
BUSINESSIOWNERNAME: CG,A551 C, rthh 4QK1C5 PHONE:_I'gl)'.
96 55
CONTRACTOR/HOMEOWNER:O,LA55(C .Ek)'(}kL� PHONE:
CONTACT PERSON FOR REVIEW COMMENTS: rR�D at�RR15 PMONE:q�40-3S 4
FAX: ('0 '39 EMAIL:
ELECTRICIAN:
HVAC:
PLUMBER:
GOOD CENTS (Residential only):
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION • SLAB ONLY
DUPLEX (Landscape Plans) REMODEURENOVATION` SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK; �i/t/CyLrnf%lrJlG y ��s�,tJT,fL.
PROPOSED USE:
HOMEOWNF-RASSOCIATION/ARCHITECl'UAL OR DESIGN REVIEW COMMITTEE APPROVAL yC'S
TEXAS ACCESS(BI �S,TANNWD Q (rAS)�JEC'� REGISTRATION# EASPFW &I/A
VALUATION: $ I (c/% TOTAL AREA:3324 HEATED AREA: 2(p g
(Cost o1 Labor aM Maiarials)
ZK PUBLIC SEWER
El SEaTio/rREATMENT SYSTEM
SEWER TAP: _q %t__
3
WATER TAP: 3
s�
a OTHER TAP:
arrE
TEMP PoL e
GARAGE TYPE: SINGLE Q
ATTACHED FZA
NUMBER OF BEDROOMS: 4
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE: 8P `C e
FOUNDATION TYPE: �O-�T u
ROOF TYPE-: '(1/1Q�S
DOUBLE TRIPLE. a
IETP C.�FD CARPORT
SIGNATURE OF APPLICANT:
'If proposed work involves new commeroial eo slxuctlo or Hc9de improve slrenovations to an existing
commercial property, building elevations are uired.
004040o0 0*004eee6*40404++ ++ a+ +s: M— --7 •
Ofircial Use Only
rip Plans Examiner Zoning Official Fire Mgshall
�r, w- e54AlleAd d-J
jgarVienta: L
CYSOor NO
Jun 20 07 02:05p Cch - B/cs yiy byu 30L3 p.3
Energy Code Compliance Information
Ma Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling I (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (Solar Heat Gain Coefficient)
Glazing U-Factor
R value of ductwork
A/C SEER Rating
Protection Against Subterranean Termites
„-T /
—3 c.
3
�
"510,
.
Chemical Termiticide Treatment (Soil Treatment)
Chemical Termiticide Treatment (Field Applied Wood Treatment)
® Physical Barriers
Q Other
*Verification of Application shall be submMed, to the City of College Station
Building Department prior to issuance of the Certifleate of Occupancy.
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 3
DATE: _ ZZ _0 -7
BUILDING ADDRESS: 02 y
I. Foundation Requirements- Minimum City Foundation Standards
NA/ K
A.
Concrete minimum compression strength of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier Emil. Poly min.
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Footings 30" exterior, 24" interior, unless over 60' long must be 30"
3. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
K
II. Framing: Floor, Wall, Ceiling and Roof Requirements
A/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Tenant separation in duplex
OK
1. One -hour rated extending to roof deck
O
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Sheathing indicated on plans for Wall Bracing
2. Moisture barrier indicated on plans
3. Exterior Wall Covering
J.
Roof framing plan or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, roof slope & purlin bracing if required to reduces an
O.
Roof covering
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only
S. All walls within 3' of property line to have protected openings.
111. Stairway Requirements
OK
OK
A. Stairway Details
OK
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than thirty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must meet IRC Chapter 10 Requirements
V. Electrical Service Requirements
A. Electrical plan to include:
NAT,
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
11
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
NA/
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NAPV
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
Street Ordinance Requirements
N
Maximum drive width for residence is 25' combined for circular and 12' minimum for single
Minimum 20 feet from driveway to side(intersecting) street property line sight triangle
Driveway access to lesser street for corner lots
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
N
Does not block an water course or divert an flow
Elevation certificate needed
OK
"APPROVED PLANS PER IRC SECTION R106.3.1."
""PLANS EXAMINER
a -o7
DATE
FRONT ELEVATION
RIGHT ELEVATION
REAR ELEVATION
LEFT ELEVATION
5 GOLOLOdM9
.� OHO
• ' W!
•
N til
_ •� �� �3a
. REAR b;.• ;d �• ���
Ltd.••.• : < :..• � �' � �
cn
u']
W2
~ ~
O
Q = o n
uj
OOJ O
a
CCU)(OQUU
J � p
�
N U cr
Q Z o Z
O MB
W 9 ZCc:
Z
L�VoZi�
cc"
—Zm
g� 0
W — O
to Q
mN~
�• N
Q
~
Z
to
m C)
0 a
J
J
0
LEFT RIGHT
o
LU
T O
N
O
O
a.
k
m
0
U
m
0
4
m
u
I—
mn
o
Q
�
�
w
o
ai
o
rt
_
k
W E
..
n. '
DETAIL
cd � ��
CL n
Q M�J ID
n
I2' Iµ
C
Z
; cm.
0)
W Q1 �
FRONT
uw
07
a
Q W
-
BRICKLEDGE WHEN
APPLICABLE
12AR WITH 2-0'
3 fR BRICKLEDGE WHEN ✓
}• ✓ ,
45° TYP. @
CORNERS
�5'p
1 •' BRICKLEDGE
'
WHEN ✓
APPUCABLE
� •' �.
APPLICABLE
SLAB STRAND'
L4:6::'=6'
CHAIR
WHERE APPLICABLE
b
- CHAIR
FP
CUSHION
I
L
CHAIR
"Z-BS°
Z
CUSHION
4LSAND, TYP.
_ _ _ _ _ _
P —' — — —
_ _ _
—
b,9 CUSHIONSAND,
DETAIL
il'P.
TOP OF POST -TENSION STRANDS
TOP OF
GRADE
POST -TENSION STRANDS
WHEN INDICATED
m
�'
0
b
'<�-?:
I �—
-
SAND, TYP.
TOP OFcv �� I ADS
66
'A STRAND
ANCHOR
GRADE •, (,
WHEN INDICATED
ON PLAN, TYPICAL
ON PLAN, TYPICAL
2- 05 BARS
¢a
w0 ¢O
O
".
.,... •.P •:•.
CHAIR
GRADE •� WHEN INDICATED
ON PLAN, TYPICAL
in
LL
_
_
,•!, I• DRAPE BEAM STRAND
•'
DRAPE BEAM STRAND
DRAPE BEAM STRAND
0
_
�'. WHEN INDICATED
WHEN INDICATED
WHEN INDICATED
'I
ON PLAN, TYPICAL
ON PLAN. TYPICAL
p
ON PLAN. TYPICAL
#4 BARS
p h
H
#3 SUPPORT STAKES
VAPOR
RETARDER
SEE PLAN FOR
@ 12 O.C.
EACH WAY
O UNDISTURBED
'BS° STRAND
03 SUPPORT STAKE
TYPICAL
}]
! F.P. DIMENSIONS
SOIL GRADE
ANCHOR
I
#
f
^ 2- #4 BARS VERTICALLY
SLAB STRANDS
DETAIL "A"
D ETAI L "Al "
SPACED O.C. AS
FORM BOARD
(
DETAIL "EII
N REQUIRED PER BEAM
r DEPTH
- a CHAIR
NOTE: IT IS IMPORTANT TO USE THIS DETAIL )
'�
WHEN
#4 VERTICAL WHEN THERE IS A 4' OR LESS SLOPE IN THE
•
✓
✓
BRICKLEDGE
APPLICABLE
SUPPORTS @ Or FOUNDATION FOOT PRINT AREA TO INSURE
THAT SETTLEMENT DOES NOT OCCUR, THE
¢ aa
D.C.
BOTTOM OF THE PERIMETER BEAM MUST
.
1- #4 BACKUP
BAR
PENETRATE UNDISTURBED SOIL A MIN OF 12i
STANDARD DEEPEN
L7 r o
TIE WIRE
•
I
...������.,._.....�..
DETAIL
CHAIR
-
CHAIR
`CHAIR
CHAIRBEAM
LESS THAN 54'
°
/ / .e •: �� SLAB STRANDS
CHAIR LAYOUT
SLAB STRANDS
SLAB STRANDS
WHEREAPPUCABLE
WHERE APPLICABLE
WHERE APPLICABLE
BEAM STRAND
2- #5 BARS
O.C.E.W.
#4 BAR
WHERE
BEAM STRAND
DRAPE BEAM
SLAB STRANDS
- APPLICABLE
WHERE
_
STRAND
SHEATHING CUT BACK BEHIND ANCHOR
APPLCABLE
-
WHEN INDICATED
- E'
(CARE SHOULD BETAKEN TO
SUPPORT STAKE
y�
#3 SUPPORT STAKE
N
"' .'• I H
ON PLAN, TYPICAL.
ENSURE SHEATHING DOES NOT
p
p �/
P�
CHAIR 3,
PROTRUDE INTO THE ANCHOR)
�,
,�%-i •• Oq 12
DETAIL "B"
DETAIL "B111
STANDARD
v
WHEN
DETAIL "G"
DROP DETAIL -
BEAM
FORM BEAM
EXCAVATION
BRICKLEDGE WHEN
APPLICABLE
l
,p.WO
BRICKLEDGE ppP
APPLICABLE �0
I
BRICKLEDGE
BRICKLEDGE
TENDON INSTALLATION
BEWHEN
WHEN APPLICABLE
AT STRESSING -END
a
Z 1-#4BACKUP BAR
g 04 BARS @ 12. O.C.E.W.
.
'
m tiN
� ? - .
;; �'•
y , ° . ,,
. ;;�,'
-1- #4 BACKUP BAR
SLAB STRAND
•'"�•
° CHAIR
mJ�
-
_
- CHAIR
}
�CFWR
• � , • � _. � r
POCKET
N ' ;Y
FORMER
TOP OF "'.'..
GRADE . Y :
SLAB STRANDS
..•.
TOP OF :: ' �
' I I SLAB STRANDS
tr .:
SLAB STRANDS
l
16'(12'MIN.)
• ,; .,
• . ..
WHERE APPLICABLE
GRADE - �•'
i.-
WHERE APPLICABLE0
_
`
APPLICABLE
WHERE,CHAIR
DRAPE BEAM STRAND
2- #5 BARS
��
., .
° .,'
-
WHEN INDICATED
DRAPE BEAM
�
¢
1
�
O.QE.W.
° 9 ,' SLAB STRANDCUT
PLASTIC
ON PLAN, TYPICAL
STRAND
TOP OF
=
•
DRAPE BEAM
- :' •.
� '• ' ' ~`�
HERE
BEAM
0 M
WHEN INDICATED
GRADE
�• 1
3 0'L AX W BEAM STRAND
EXCAVATION FORM .
ON PLAN, TYPICAL
: ' �"
WHEN INDICATED
AS SPECIFIED
m
H VT
r
ON PLAN TYPICAL
1•#4 FOR L=14'OR LESS
PL ;Y,'
2- #4 FOR L=1s TO 25•
COMPLETED
DETAIL "C"
DETAIL "Cl"
p
•F
s
E: DETAIL°F' 3 #4FOR L=2sio3s
STRESSING -END INSTALLATION
SUBTITU�
D
[FORSOTAN BE
DETAIL 'IF" °. D ETAI L "F 1 "
BRICKLEDGE WHEN
DETAIL
1
APPLICABLE
'S' STRAND AS
BRICKLEDGE WHEN
SHOWN ON PLAN
1�' MIN.
3#,
r
✓
APPLICABLE
PLASTIC
PLASTIC
.
N
FIXED -END
-
1#4 BACK UP BAR
NOR
� ACH
STRAND
:..::...
-
...
-:.• CHAIR
;-
3'}•
ro
CUSHION
-
CHAIR
SAND. TYP.
-
CHAIR
- 17
10'STRIP
TOP OF
POST -TENSION STRANDS
.�;i,';"•
SLAB STRANDS
WHERE APPLICABLE
Z
`i
• •
SLAB STRANDS
SHEATHING
GRADE
WHEN INDICATED
a
WHERE APPLICABLE
20d NAIL
'BS' STRAND AS
ON PLAN, TYPICAL
#4 BRAS @ 12
(MIN.)
STIRRUPS
STIRRUPS
WHEN SPECIFIED
'N
-
o.C.E.W.
2 X 0 TYPICAL SHOWN ON PLAN
WHEN °STRANDS ARE
FIXED -END (DEAD-END)
WHEN SPECIFIED
•
•
•-+�'
DRAPE BEAM
#3 STAKES AS REQUIRED
SPECIFIED ED IN THE BEAM,
WOOD
FORM INSTALLATION
M
p IY
� m
STRAND
TO MAINTAIN A 3'
TIE •BS' STRANDS TOGETHER
TOP VIEW
p
3- #4 BARS
3- #4 BARS
V�
WHEN INDICATED
CLEARANCE FROM THE
AND INSTALL SIDE BY SIDE
TOP & BOTTOM.
TOP & BOTTOM.
p
M
ON PLAN, TYPICAL
BOTTOM OF THE BEAM
%S A SINGLE'BS' STRAND.
'
'
1�00
�55
54' MAX. SPACING
INSTALL ANCHORS SIDE BY SIDE
_
SEE •2-BS° DETAIL
STANDARD DETAILS
DETAIL I'D"
DETAIL "H"
DETAIL I'M"
BEAM STRAND "BS" DETAIL
+1
a v
cn @
N
r-
S24
U
5 SPACES p 4'-2"t
LNa m LO N
fn -- !n N (n--- co
2 S PACES
p 3'-8" t 1,3 SPACES @ 3'-2't
5 SPACES (P V-11"t
I I
14.
!I
I
()
U)
m ai
U)
---------�L--------
-------�L
-------
-------
r--- ir--------�
I II II
--
-
r--
-- - r -------
--�i
I II II
I
I
II I
II 3-#4B II
88" TYP
I I I
I I I I
I
I
11
t
l o
I I O I IFq
I Icc
I I I I
I II II
I 1 1 ran
II
I I I I I I
II
II II
L - - - - -----� L--------J
tl
L-----JI L-----
I II
-J L - - - -----J L
----- -
II II 11
I II II 11
II II
II.
II 11 11
I I I I I 1 1
II II 11
II
I II
I I I iq
II Ilih
II II II
I II II B
II II
II II
I II II 11
L----------JL--------J L_-----1 L-
II II
-----J L--------J L
---��
r----------� r----------I r------i r-
-----I
r---------- r
- - - - - -
9'-10" 1 1 T-4" I I
I I t&A 1"
I I I I11 111
i—
I I I11
II II II
I II II 1
I II II I
I II II 11
II II
II II
II III
II II
T'� II II 11
II III
L---------JL--------- L--- -J L - - - - - - - J L - - - - - - - - - J L
-------
�------
i
---�r--------ter--
II II 11 II II
------
I
I P
II II II
11
I I I ROP I
II II
II II
I I iq
I I
I
II II
I
DROP
I
II II
I
II
II
L_ __-_
II
II
_
r
------ -
� r
------
NBS21
L
II A I II I
-� I I I I
im I II I
I II I
L�___-_JL
A I II I
II I
I II� I
I III
IIr
I II I
L _
E3
600LOLOAd NOTES: * • �h
1. TO PREVENT SETTLEMENT DUE TO SOIL CONSOLIDATION,61 ajl••.•• •.•j
ALL EXTERIOR FOUNDATION BEAMS MUST BE FOUNDED A �,• 5���
MINIMUM OF 12 INCHES INTO UNDISTURBED SOIL. WHEN "�: • p Ott) • J
DIAGONAL FOUNDATION SITE CONTAINS FILL (MAX. 3'-0'), THE DEEPEN : W
BEAM DETAIL SHOULD BE USED IN THESE FILLED AREAS. O .
FOR SITES WHERE FILL IS GREATER THAN 3'
i-0", PLEASE ;� t��'•
S23 CONTACT AGTM ENGINEERING LLC TO INCORPORATE PIERS Y6'•• Qj�
B 24 INTO THE DESIGN. �� '•..e a ;.•'��`Y/�
2. 3000 PSI, CONCRETE SLAB.
- E +1 3. 4" OF CUSHION SAND UNDER CONCRETE SLAB IS `�'►V��•�
S23 a RECOMMENDED.
4. PROVIDE AS MIL POLYETHYLENE MOISTURE RETARDER
`D BENEATH SLAB AREA. Z
S23 5. ALL STRANDS 1 /2" DIA. - 270 K. O Un
co 6. THIS FOUNDATION DESIGN IS CONSIDERED INVALID
S61 UNLESS ACCOMPANIED BY A LETTER FROM AGTM ~ W r��c� W �-
BS82 ENGINEERING LLC AUTHORIZING ITS USE ON A SPECIFIC Q Y H y
LOT & BLOCK, OR ADDRESS. C, O I-
7. PLANS CAN BE REVERSED ON LOT AT BUILDERS Z = ^ LO W W z
S61 DISCRETION. _= j o J J p
8. PLANS ARE FOR STRAND AND BEAM PLACEMENT ONLY. O O0 X c� (co Q W
S81 SET FORMS, DROPS, HANDICAP RAMPS, ETC., BY U) p N UU
ARCHITECTUAL FLOOR PLAN OR AS SPECIFIED BY _ CD Y O
2-BS82 OWNER/GENERAL CONTRACTOR. z Z" o a O 0 Q
S81 9. AT CONTRACTORS OPTION, LIVE END AND DEAD END O W F- Z z cn �: m
REVERSAL IS PERMITTED. - V= Z' z Y Z p
S61 c 10. AT CONTRACTORS OPTION, BRICK LEDGE MAY BE
INCLUDED OR OMITTED AT EXTERIOR DOOR OPENINGS. z Fn p Q m u Q
Sal 11. DRAINAGMAND
PAWAY
E. THE FINAL GRADE Cn N N U)
BS82 AROUND THE8" BELOW THE TOP OF
a THE FOUNDAROM THE !"' U O OJ W861 oFOUNDATION � J
O o
12. VIBRATE CONCRETE Q ALL CABLE LOCATIONS a 0 S81 ESPECIALLY AT CORNERS WHERE SEVERAL.CABLES ARE .3
BS82 ANCHORED. MAXIMUM CONCRETE DENSITY IS REQUIRED
TO INSURE THAT A "BLOW-OUT," DOES NOT OCCUR DURING
S81 CABLE STRESSING. i r o O
13. THE FOLLOWING SYMBOL INDICATES DROP IN N
S81 FOUNDATION. THE AMOUNT OF DROP AND EXACT o p
LOCATION IS TO BE DETERMINED BY PLAN OR AS o
S81 DIRECTED BY OWNER/CONTRACTOR. o
Sal ILL
H
2-BS82
a
S2 FOUNDATION: o
S24 1. THICKNESS T= 4" m
@� 2. BEAM WIDTH W= 110" O
BS25 3. BEAM DEPTH D= 28" 8 4
S24 w 4. AREA = 3358 SQ. FT.
5. EST. CONCRETE = 1113 YRDS. m o a
S24 o Q
S24
BS25 00
O—STEEL REQUIRED. SEE DETAILS J W n E
�' Q�'m
�
g$ W
CD O�aU
CAUTION: IN THE EVENT THAT A CABLE •C lL N
PASSES THROUGH A PLUMBING OPENING, CAUTION: VIBRATE ALL CABLE LIVE
MOVE CABLE TO EDGE OF OPENING. AND DEAD, ENDS TO ENSURE MAX. W 1 j L J
CABLE SPACING CAN BE ADJUSTED, DENSITY CONCRETE, ESPECIALLY
F- u
Q
NO EVENT CAN CABLE SPACING BE AREAS WHERE MULTIPLE STRANDS a Q W
GREATER THAN 5'-0" O.C. COME TOGETHER
ngineering, LLC
401 S. CLAY STREET, ENNIS, TX 75119
July 6, 2007
Classic Century Homes
5001 Hwy. 287 South
Arlington, TX 76017
The following post -tensioned foundation plans are herein authorized for construction at the address and legal
description shown below.
Lot Blk Subdivision Address City County State
23 1 Castle Gate 2453 Newark Circle College Station Brazos TX
A site specific soils report was not provided. The foundationhas been designed based on the following soils
conditions.
Soils Laboratory
Brazos County USDA Soils Survey
Allowable
Bearing Pressure P.I.
1200 psf 36
The foundation design is in accordance with the applicable provisions of the International Building Code
2000/2003 Edition, the International Residential Code 2000/2003 Edition, the Design and Construction of Post -
Tensioned Slabs -on -Ground, Second Edition, 1996 by the Post -Tensioned Institute, applicable provisions of the
Building Research Advisory Board (GRAB) Publication 33, and accepted engineering practice.
If you have any questions, please call me at 972-878-3647.
PTF0707009
71612007
A.G. (Tony) Medina
Registered Professional Engineer
PHONE: 972.878.ENGR (3647) • FAX: 972.875.1398 • E-MAIL: info@txfoundations.com
77.65'
10' P.U.E
b'
r - - - - - - - - - - - - - - - - - -
- - _
M
�
O
I
O
Ir
M
I
I
I
I
I
- - - - - - - - - - - - - - -
�
I
I
I
- -
I
I
I
I
I
I
I
I
I
I
I
I
I
I ONE STORY
I
I SINGLE FAMILY
W I
►-� I BRICK RESIDENCE
I
PLAN # 2688
aI
�I
I
-
o
N `n I
I
cot on
15'-11 17/32"
—
I I
25'-0"
I I
I I 18' CONC.
I DRIVEWAY
I I
\ C
12'-0"
cl
-- t - ---- - - - - --
_ _
57.5' 5' P.U.E I
Mr.%
2453 NEWARK CIRCLE
LOT 23, BLOCK 1
CASTLE GATE
COLLEGE STATION, BRAZOS CO.
TX
FLATWORK 916 SQ/FT
GRASS 220 YDS
O
O
N
BRICI
W 1" PROJECTION
I,Au .l.E� IZh d x o UL In
Tx 1'6" AR TR
DL 1/1 MULLED (2)1'6" x 6' DL 111 ROWLOCK
Tx 1'6" AR TR TO SURROUND WINDOWS
PLAN#
2688
CS,� •
Century
Homes
ADDRESS
2453 NEWARK CR
LOT
23
BLK
1
SUBDIVISION
CASTLE GATE
58'8" (Ao(j-&u ?Aowe f -
21' 10" 16'0" 20'10"
18'2" 3-8. Cv
3' 8* x 6'0" y a, . 6'0* 3'8* x 6' 0'
3'8" x 6'0"
---------------------------------
;o
0)
nl
b
FAMILY
MSTR SUITE
Eo
8'- 9'CLG
8' - 9'CLG
13'0"
3-0-
lalialimmalill
Illisailaiialilill
ilia
lifillail
5111" L 5'7" L 3-8" 2' 4" L
414"
.—
PORCH
I
--------------
--------- ------
io
10'CLG
L 10r Orr
zr
CD
REAKFAST
b
8'- 9'CLG
42"T
---------
KS
LJLJj
3'8'x 8'(r
3'8. Ir 0* 3'1'xB
b
8'CLG
w
KITCHEN
8'- 9'CLG
-8-
L 3' 8-
6
0..
T
b)
E= ZOO
;o
N
b
N
17'11*
y 4-8-
10. 3-8-
1211'
Go
a
1'4
LIN
10'CLG
R
M6 1
11 (56-2-
-
U
5*
LIVING
LIN
1-4-
Ld
ur
10'CLG
B 00
2-6-
2'0*
2
4-7" 2-4-
6-
00
b
00
;o
in
PLANT SH @ 8'6* 4'10*
1
P 9 314*
,
--------------
:[
28'
. .........
-- -- --
z z z
-
6 2" N 1 u
4-0- NL 2.4ih
6- 7r
00
--------
----------
10, CL
3
z 01
-----------------
---
2-8-
.1
6-3- 1 10-1
3-8-
DINING::
I
8- b- BOX
11
FRI
ill 9"
3-8"
7'10"
5-2-
11 2"
6-
12' 11"
BDRM 2
D
zo
BDRM4
8'CLG
8'CLG
I ----------------------
I
L
Z8*
b
BDRM 3
,
------------
WH
9'CLG
10, C Lp
3'10
12-5-
12' 10"..
- -----------
FOOTAGE
[WINDOWS
SEEELEVATI �)NS
FOR
1.4-
4' 0"
1.4-
LIVING 2688
4
SIZE A
D LOCATION
FRONT PORCH 31
NOTE:
1) SHABED
WALLS TO 2" x 6" FOR PLUMBING
BACK PORCH 138
2) ALL
EADER HEIGHTS TO BE 6'1("
UNLESS OTHERWISE NOTE
D
zo
GARAGE 471
;o
3) PROWDE
TEMPERED GLASS WHF RE
NEEDED
TOTAL 3324
b
in
P
AN #
12688
11
sic
tury
nes
ADI,REss
12453 NEWARK
CT
Cen
Ho,
LOT
123
BLK
1
LS�BD
ISION
ICASTLE OATE
mamv,...
.—wpv.,d4"
C14
GARAGE COPYRIGHT 1998
8'CLG
FRED BURRIS
--------------- ---
11' 2" 11'4" 6-8- 7-6" 22'0"
58-8"
ROOF A5 5ELECTED
9 8:12
REAR ELEVATION NOTE:1) Foundation anchor bolts at
PLAN # 2688
lessic
ADDRESS 2453 NEWARK CR
LOT Century
!
BLK Homes
SUBDIVISION CASTLE GATE u.•",. o..�m��..
6'0" o.c. as per 2000 IRC
sec. R403.1.6
2) All framing and structural
design to meet 90 m.p.h.
wind criteria as per sec.
R301.2.1 and table R301.2(4
2000 IRC code.
00
3) All lower sole plate to be 4) Provide hand rails on all stairs/steps
Pressure treated as per
with a minimum of 2 risers as per
sec. R323. All fasteners
sec. R315. (min. stair tread 10":
to be hot dipped galv. steel,
max. riser 7 3/4" sec. R314.2)
stainless steel, silicon bronze
5) Masonary veneer anchorage of
or coper only as per sec. R323.3
24" horizontal and 18" vertical as
per sec. R703.7.4.1 and weep holes
at a maximum of 33" o.c. as per
sec. R703.7.6.
0
n
-------------------------------
MSTR SUITE
8'-9'CLG
BLOCK & WIRE
FOR FAN ONLY
8' CLG
7 "
BDRM 2
8' CLG
ceiling fan spotlights 1
®
fluorescent fixture
p
pot light
s=&.L.sL&
Ivanity bar light
®
Ifan
light
outlet
outlet 220v
outlet gfi
®
smoke detector
$
switch
switch 3 way
BDRM 3
9' CLG
PORCH
10' {CLLG
'T
-----------------
I I ;
II,
4^,
,1 I
' 1 1
11
1 ftj di I
FAMILY
8'-9'CLG
------------
8'-9'0LG
LIVING PANTRY - - -
1Q�CLG a oonn
lyu I
1�� I
I1 1•L•- •T I I
}T_____________
10- CLG
i
---------------------
I I % I I
II
II
II
II FRZ'
if
II i4
II �
DINING
I 8' 9' Box D }
10' CLG
NOTE:
1) Lighting on stair to conect from switch @ top to
light mounted on wall @ middle of stairs to switch
@ bottom of stairs per sec R303.4
2) Smoke detectors will be hard wired in series
w/ battery backup power as per sec. R317
3) Provide 110 outlet & light near HVAC unit for
service with switch.
PLAN #
2688 ELECTRICAL PLAN
lassie
Centur
Homes
ADDRESS
LOT
�me Ownership Affardrtb
Q.
KITCHEN
-� 8 - 9 ;CLG
REF
ip ip'" ipr
0 ..J •
BDRM 4
8' CLG
GARAGE COPYRIGHT 1998
8' ct G FRED BURRIS
IYPIfAL 1x4 SDnvO fixrG10R WAIL:
SHINGLES
IrLluTnmc
clwroaollsnm vEHrBwf3lESF. M•nc
'tea' x
h, SrUe3G 16'u.
FIT 11—sysrEM: GDS ATRIdiE ro BEIMTALLEDSOTIAT
W T&GL`SnwR AIt nAP'CS NOT 0.ETrtl('IFD
tU 9ATTIISWA c,`
Im YPslml aoAan
COBmaEE PA(AD MDnaC%NFBS
mTER3m,Enar Exca'EEx '0". uaRIPTEts@M'oc _
INrtxroacOuno Flxlsx
3x,a0T10MPIATE
Ul PLVxUCx)SmA`n NG
H EUPS
BAIT INSUTAnON FUR :.' OF F-1
PTAINE0.nGIRUDLRING
MKALT%, Rtlp; E%hvroR WALL:
TOPIATE3 FASCIA
,•FILE a0.1LX
MErAL eucxlw.s
I• Aa13P
I?BARNUERNG
TI
AI
B M'UFIILOE
lM
. SrUC 0 IS',..
F1.00RTSBN
col EOWLLYBlA®vFNFS
DFrroptnE
0.M fiAR06D1ATRM
BATUD
IP'EEP VEN3EVFAY 3tDatRa (a PO.0
@eo.
1?SHEErROp;
ATaOnON)
MBTIL BRIIXT2t METAL aRILxlrEs
1'Aal31ACE I'ARSPALE
Irvuwrxnro Ir avwrlm,D
AI8 aAMD:0. All, RAR?m
h4SoJCSLR — h,s=@IS•oC
,,, aATLiN3ULATroNI Rn—IASDLATroN
?SMMICLR INI ITS141FROCK
:x, wmoM ruFa rRE3T03 u4
J° • 9;
ALLSLV3 dMENBNNSIW(%NGSES,
1
aRFINIORCGIEYFTU Bl ULT!]AONlLaY
PI °, P 11�
FVGLVEER
TYPICAL ROOF
in'
SNNGLES
PLYWOOD SNEATHING
c/W W CLIPS
MIN. 7"X6"
CONTINUOUS
RAFTERS o 24" o.c.
BATT INSULATION
AIR VENT BAFFLES
oza° o.C.
ROOF PI'
END AT RIDGE
TO BE INSTALLED r
SO THAT
AIR FLOW 15 NOT I
1✓/'
RESTRICTED
F(OVERNAN
WOOD FASCIA
SOFFIT MATERIAL
TYPICAL BRICK EXTERIOR WALL
FACE BRICK
I' AIRSPACE
IR" SHEATHING
2"N4" STUDS a 16" o.c.
BATT INSULATION CITY OF LOCKWART
VY SNEETROCK TYPICAL ROOF OVERI-IANCs DETAIL
Sx Rfra
M .gin rus
I•A@SPAcE
ICSHGInm
AIR RAWFI
T%, Snms g lv—
R13"ITD31RArxR,
U SREEI9MS
ALLS ABUIXE AIUAS HCY)E4Q
R!]N3D0.flAthlRlo BEULTF]UUNFD 03'
j �.; .4 UiGI1ffF1
:.a .r
TOP VIEW ,6
CHIMNEY CAP
FLUE CHIMNEY
2X4 BAND ; CAP
2X4 BAND
2X4 FRAM G,'
- N
I
MEMBER - 2'- 45 - 2X4 FRAM
MEMBER
SIDE VIEW OSB
SIDING -
TYPICAL WALL DETAILS
NOTE:
1) Foundation anchor bolts, at
60" o.c. as per 2000 IRC
sec. R403.1.6
2) All framing and structural
design to meet 90 m.p.h.
wind criteria as per sec.
R301.2.1 and table R301.2(4)
2003 IRC code.
3) All lower sole plate to be
Pressure Created as per
sec. R323. All fasteners
to be hot dipped gale. steel,
stainless steel, silicon bronze
or caper only as per sec. R323.3
4) Provide hand Fails on all stairs/steps
with a minimum Of 2 risers as per
sec. R315. (min. stair tread 10":
max. riser 7 3/4" sec. R314.2)
5) Masonry veneer anchorage of
24" horizontal and 18" vertical as SPHERE SHALL RENRN ENDS M
per sec. R703.7.4.1 and weep boles NOTPASSMU Q" WALL OR POST
at a maximum of 33" U.C. as per HANDRAIL 1 IM• MIN. Q Z
sec. R703.7.6. T02vr MAX.Svs so
..................... o
18" FLOOR SYSTEM
----------------------------------------- -----
DC
IN. TREAD
d w >< (3)2xl2 STRINGERS
5 V
>< 5/8" TYPE DRYWALL x
x i UNDER STAIR STRINGERS a
V
u HANDRAIL n 34"-38" MAX.
to FIRST FLOOR
�O 7
STAIR DETAIL IRC 2003
'JIIIG 2' 4" 10' 0" MIN.
Z
I I _
I I O
I I
SM
p hustc
Century
Homes
Making Home 0—anhip Affordable
Area Calculator:
Add to
Library
Window
Name
Assembly Type
Quantity
Width
xHeight
Unit
= Area
Total
Area
U-Factor
SHGC
Comments/
Description
1
3'8" x 6'0"
Metal Frame, Do
6
3'-8"
6'-0"
22.00
132.00
ft2
2
4'0" x 4'0" fixed
Metal Frame, Do
1
4'-0"
4'-0"
16.00
16.00
ft2
3
3'8" x 8'0"
Metal Frame, Do
3
3'-8"
8'-0"
29.33
87.99
ft2
4 1
ITO"
x 60"
Metal Frame, Do
2 1
3'-0"
6'-0"
18.00
36.00
ft2
5
2 - 2'8" x 6'0"
mulled
Metal Frame, Do
1
5'-4"
6'-0"
32.00
32.00
ft2
6
3' x 1'6" AR TR
Metal Frame, Do
2
3'-0"
1'-6"
4.50
9.00
ft2
7
2 - 3'0" x 6'0"
mulled
Metal Frame, Do
1
6'-0"
6'-0"
36.00
36.00
ft2
8
1'6" x 6'0"
Metal Frame, Do
2