Loading...
HomeMy WebLinkAboutRES2007-02189, 07-2190moo; i qo , WFO949998 / 001 City of College Silatiori PAGE 1 REQ. DATE: 08/10/07 08/10/07 8:16:40 LOCATION: 2461 NEWARK CIR LOC ID: 204002 REQUESTOR: CLASSIC CENTURY HOMES ORIGIN: CUSTOMER -WALK IN REQ USER: GLSOUTH AUTH USER:GLSOUTH WRK TYPE: SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 08/10/07 SCHED COMPLETION: 08/10/07 ******************************************************************************** JOB ORDER RESULT COMMENTS gineering, LLC 401 S. CLAY STREET, ENNIS, TX 75119 July 6, 2007 Classic Century Homes 5001 Hwy. 287 South Arlington, TX 76017 The following post -tensioned foundation plans are herein authorized for construction at the address and legal description shown below. Lot Blk Subdivision Address City 19 1 Castle Gate 2461 Newark Circle College Station County State Brazos TX A site specific soils report was not provided. The foundation has been designed based on the following soils conditions. Soils Laboratory Brazos County USDA Soils Survey Allowable Bearing Pressure P.I. 1200 psf 36 The foundation design is in accordance with the applicable provisions of the International Building Code 2000/2003 Edition, the In Residential Code 2000/2003 Edition, the Design and Construction of Post - Tensioned Slabs -on -Ground, Second Edition, 1996 by the Post -Tensioned Institute, applicable provisions of the Building Research Advisory Board (BRAB) Publication 33, and accepted engineering practice. If you have any questions, please call me at 972-878-3647. PTF0707006 Sin r IYqu^ OF I-, :.. .............. 9, 50995 g4de��OidA!-��e 71612007 A.G. (Tony) Medina Registered Professional Engineer PHONE: 972.878.ENGR (3647) - FAX: 972.875.1398 - E-MAIL: info@txfoundations.com U EYEBROW — -- PLAN# 2156 lassic Century Homes ADDRESS 2461 NEWARK CR LOT 19 BLK 1 SUBDIVISION CASTLE GATE J u 1. 30. 2007 9 : 03AM No.5701 P. 4 3 /.Ub' 2461 NEWARK CIRCLE LOT 19, BLOCK 1 CASTLE GATE COLLEGE STATION, BRAZOS CO. TX FIATWORK 940 SQ/FT GRASS 220Yp 55' 0" Lo 14' 8" ----------------- 6' 7" ' MSTR SUITE 8'- 10' CLG 8' CLG 0o r o• KS r a• 3' 8" UTIL. ih 4' S b n Nr /¢ \ � ILE I NOTE: 1) SHADED WALLS TO 2" x 6" FOR PLUMBING 2)'ALL HEADER HEIGHTS TO BE 6'10" UNLESS OTHERWISE NOTED NOTE:1) Foundation anchor bolts at 3) All lower sole plate to be 6'0" o.c. as per 2003 IRC Pressure treated as per sec. R403.1.6 sec. R319. All fasteners 2) All framing and structural to be hot dipped galv. steel, design to meet 90 m.p.h. stainless steel, silicon bronze wind criteria as per sec. or coper only as per sec. R602 R301.2.1 and table R301.2(4) 2003 IRC code. RIGHT ELEVATION LEFT ELEVATION REAR ELEVATION 4) Provide hand rails on all stairs/steps with a minimum of 4 risers as per sec. R315. (min. stair tread 10": max. riser 7 3/4" sec. R314.2) 5) Masonary veneer anchorage of 24" horizontal and 18" vertical as per sec. R703.7.4.1 and weep holes at a maximum of 33" o.c. as per sec. R703.7.6. D nnU UT UATA TTn-XT ALL EXTERIOR LIGHTS RAN TO TIMER GARAGE NOTE: 1) Lighting on stair to conect from switch @ top to light mounted on wall @ middle of stairs to switch @ bottom of stairs per sec R303.4 2) Smoke detectors will be hard wired in series w/ battery backup power as per sec. R317 3) Provide 110 outlet & light near HVAC unit for service with switch. PLAN# 2156 ELECTRICAL PLAN lassic ADDRESS p LOT Cv n t%/ ry BLK Homes SUBDIVISION ELECTRICAL COUNT SYhIROL ceiling fan spotlights 2 2 exterior light 3 3 10 double spotlight I QP fluorescent fixture I single spotlight 4 Q vanity bar light 2 0 0 0 0 0 fan 3 light 15 outlet 29 outlet 220v 2 outlet gfi 13 �cw smoke detector 6 switch 26 Q switch 3 way 4 t In•SHEAmn' AIn RARRfR h1ETUD3 fa 16'u. P11 BATT R3U4TUN In•cwsUM mAnn u4 aOTmA rink GATT MnRATNN fUR:P OF iLWl aEATIEP TIclrtuuumc — TYrMAL1X4 BRIM EXTERIOR WALL MREAL BRIO:C SIACKJtEs IW S :-AIRSPACE NO AIR BARMIER RU BATTaisIMTPA 1n'sHEEIROCI: HEIR APXTIEt I'AdP S WSIATH O AIR aAJOLIELRRnR .11 RII BATTnON ITsxEel"OrRRotY :x. BnRON—n TnP. — mIcarloDRsY1 m W'iaGSUBFlAIUR TRIr:S SPANiG MD IIDCxNFSY IN BEDEFFAI BYOa'NEFA INTFAIOiI cDUNO TNc rixux BPRY C1M:ca<TU UNDEnEIDE D VENT xET laTEP ffi T) EVERY 10.Da0.1CR AT BOTTOM) N► o c's t� Id.Ax & ' e '1 AU EIAB niNET3RA1ETwfRNFSEF$, J ' a � aazNloecFelertroek oLTLYAIUT>t ar yrENGINEER TYPICAL ROOF 1 SFIMGLES WPLYWOOD SHEATNING e/W 'W' CLIPS MIN. 2'X6' RAFTERS o 24' .... BATT INSULATION CONTINUOUS AIR VENT BAFFLES a24' O.C. ROOF PI' END AT RIDGE TO BE INSTALLED 50 TNAT AIR FLOW B NOT I (OVERR DECKING AN RESTRICTED MAX. D WOOD FASCIA SOFFIT MATERIAL TYPICAL BRICK EXTERIOR WALL FACE BRICK I' AIR SPACE 1/2' SHEATHING 2'N4" STUDS W W .... BATT INSULATION CITY OF LOCKHART 112' SHEETROCK TYPICAL ROOF OVERHANG DETAIL slnNtaTs CWrtp'DWAALL VFRDIST IFa§2AITHA Art n)DRIS iOTR TRICIEAUFO50TNAT AIR FLOY' C{ NOT 0.E4191Cf FD NO N.-xArrTRsV r.'OL In• RVWDOD SHFATHIHU HMS FASLIA --16 SOTRIT WIEOUALLYSPAQLVFATS QAO.c METALan-m 1•ABSPArE In•SNEATHDIO Ant BAPPDA II. S111DSO u." RUBATTtNSI ON 1. SHEETROCR MLTWQCS NOTE 1) Foundation anchor bolts at 60" o.c. as per 2000 IRC sec. R403.1.6 2) All framing and structural design to mat 90 m.p.h. wind eritcria as per see. R3011.1 and table R301.2(4) 2003 IRC code. 3) All lower sole plate to be Pressure treated as per sec. R323. All fasteners to be hot dipped galv. steel, stainless steel, silicon bronze or toper only as per see. R323.3 4) Provide hand mils on all stairs/steps with a minimum of 2 risers as per sec. R315. (min. stair tread 10": max. riser 7 314" see. R314.2) 5) Masonry veneer anchorage of 24" horizontal and 18' vertical as per see. R703.7.4.1 and weep holes ate maximum of 33' o.c. as per HANDRAIL 1 IN• MIN. see. R703.7.6. T0 29 8 •MAx SnPa iEIRFA'n^ O nuaLTDr+aFsws¢xry 'I A<,saa aTk1 BY V ;I. 1. co TOP VIEW W CHIMNEY CAP Lt 2X4 BAND I I Y (V 2X4 FRAMKG - MEMBER TYPICAL WALL DETAILS SIDE VIEW CHIMNEY CAP 2X4 BANE 2X4 FRAM MEMBER OSB SIDING - nor SPHERE SHALL NOT PASS THRU RETURN ENDS TO 4' a•ALL OR POST iG� iu °o IS" FLOOR SYSTEM -AD (3)2x12 STRINGERS F 5/8" TYPE DRYWALL x UNDER STAIR STRINGERS V HANDRAIL @ 34"-38" MAX. FIRST FLOOR STAIR DETAIL IRC 2003 2' 4" 1 10' 0" MIN. a,, &assic Century Holies Making Mom, ON•nenhip AJ/ordable Area Calculator: Add to Library Window Name Assembly Type Quantity Width x Height = Unit Area Total Area U-Factor SHGC Comments/ Description 1 3'0" x 60" Metal Frame, Do 3 3'-0" 5'-0" 15.00 45.00 ft2 0.650 0.340 2 2'0" x 6'0" Metal Frame, Do 2 2'-0" 6'-0" 12.00 24.00 ft2 0.650 0.340 3 3'0" x 3'0" Metal Frame, Do 1 3'-0" 3'-0" 9.00 9.00 ft2 0.650 0.340 4 2 - 3'0" x 6'0" mulled Metal Frame, Do 2 6'-0" 6'-0" 36.00 72.00 ft2 0.650 0.340 5 3'0" x 6'0" Metal Frame, Do 1 3'-0" 6'-0" 18.00 18.00 ft2 0.650 0.340 6 47 x 4'0" fixed Metal Frame, Do 1 4'-0" 4'-0" 16.00 16.00 ft2 0.650 0.340 7 3'0" x 1'6" TR Metal Frame, Do 1 3'-0" 1'-6" 4.50 4.50 ft2 0.650 0.340 8 3'0" x 6'0" 1/2 EB Metal Frame, Do 2 3'-0" 6'-0" 18.00 36.00 ft2 0.650 0.340 9 3'0" x 7'0" Metal Frame, Do 1 3'-0" 7'-0" 21.00 21.00 ft2 10 11 12 13 14 15 16 17 18 19 20 21 22 ew 4i.< C °- Window Area Total: 245.50 1/1 Area Calculator: NEE Assembly Type Description Door Area Total: 55.56 1/1 SIMPSON LSTA21 OR CS20 (ATTACH TO FRAMING ON OPPOSITE SIDES OF r SHEATHING) TYPICAL BOTH SIDES / OF OPENING. 4" MIN H ►�I0 :ADER XEAR SPAN 6' :6 (BETWEEN 6' TO 181) T • oe • D G a .Q b. •9 G D .. - 3" GRID PATTERN 8d COMMON NAILS TO HEADER TOP PLATE TO K HEADER - 2 ROWS OF 16d SINKERS, 3"O.C. 3" O.C. NAILING IN ALL FRAMING -STUDS, BLOCKS, TOP PLATE, AND BEHIND THE . STHD10 HOLDDOWN 5/8" TITAN ANCHOR BOLT MIN. r EMBED. DEPTH - 4" TYP. v-1800 LB HOLDOWN ONE-STORY STRUCTURES CAN USE SIMPSON HTT16, PHD2, HDU2, OR STHD10 HOLDOWNS. Flj-STQ RY_24"�MIN. FRONT ELEVATION 5'-0"MIN. 1xaLET•ININroTOPAND 5'-O°MIN. TY BOTTOM PLATE AND TYP. INTERVENING BTVDB TYP. TYR / TYR I. LESS THAN 1 Z-W I, LESS THAN 25.0" L LESS THAN 1 Z-T RIGHT ELEVATION BOTTOM PLATE AND 5'-O'MIN. INTERVENING STUDS. TYFI. Rucrumi:7 �`�►\-\Q i�A�All REAR ELEVATION q LEFT ELEVATION Z WL0L0dM9 FRONT �; ; qth m B * . .�,i,�,��. .• •, I: Z .•�y o00 07 LL Le of :�• .Q.w �:• _d:� _� �►••..,; d .•• a �, uw W� z w a. co cc _jmooX , T-a()ccn J t F- O N UFO QZ`�0Z Om� LJJ Z Z ,.. mow U= cl Z w ZLL YZo U�0aQ a`Vc~n w Li U p p w CO O pp U O IL w Tn 1"' O N O O 0 a m LLi 0 O U m O d ° m 0 m :5 O Q ul � S o v�i o fu aC J W E 8 > cdgi CL 1, cd Q U, C 0 N N _ ' ' v A—Lu w ILL.a QF- W I BRICKLEDGE WHEN 6 APPLICABLE 12' # 3 REBAR WITH 2'-0• .,a BENT @ 45° TYP. @ BRICKLEDGE WHEN r 1" BRICKLEDGE WHEN APPUCABLE C ALL CORNERS SLAB STRAND ail� - CHAIR WHERE APPLICABLE 2 '-• CHAIR m F_'I,` CUSHION _ CHAIR -CUSHION SAND, TYP. — — _ _ _ — _ — — i "2-BS" DETAIL �JZS �� CUSHION ^�N _ SAND. TYP. TOP OF POST -TENSION STRANDS cc p >- +� a :. SAND' TYP' 6'6' �'$° STRAND ,I WHEN INDICATED a LL °� I TOP OF •) POST -TENSION STRANDS GRADE ¢A'I�I I GRADE - I WHEN INDICATED 7', :: ON PLAN, TYPICAL a ZO — I — TOP OF '•I POST -TENSION STRANDS ANCHOR 1':.'• . ON PLAN, TYPICAL 2• #5 BARS ¢ ti - !.• .:: •:.6: _ GRADE WHEN INDICATED ¢ ... CHAIR ' • • i ON PLAN, TYPICAL in DRAPE BEAM STRAND Tn DRAPE BEAM STRAND p p — I .P. S I — DRAPE BEAM STRAND WHEN INDICATED WHEN INDICATED 'II ^� e WHEN INDICATED ON PLAN, TYPICAL 0 n ON PLAN, TYPICAL 44 BARS , ON PLAN, TYPICAL O In #3 SUPPORT STAKES VAPOR @ 12' O.C. O UNDISTURBED 'BS' STRAND #3 SUPPORT STAKE RETARDERF.P. DIMENSIONS FOR EACH WAY TYPICALF k. SOIL GRADE ANCHOR J 2- #4 BARS VERTICALLY SLAB STRANDS DETAIL "A" D ETAI L "Al " SPACED @ 12' O.C. AS FORM BOARD REQUIRED PER BEAM D ETAI L "E" M �, DEPTH CHAIR NOTE: IT IS IMPORTANT TO USE THIS DETAIL ) '" •••f #4 VERTICAL WHEN THERE IS A 4' OR LESS SLOPE IN THE BRICKLEDGE WHEN ✓ @ SUPPORTS 48' 111 ,R r APPLICABLE FOUNDATION FOOT PRINT AREA TO INSURE / ¢ • a¢ / \ O.C. 0 THAT SETTLEMENT DOES NOT OCCUR, THE 1- #4 BACKUP BAR BOTTOM OF THE PERIMETER BEAM MUST p STANDARD DEEP PENETRATE UNDISTURBED SOIL A MIN OF 10) c7r WRE � CHAIR ST BEAM DETAIL EN �.�.,..,.,....�..,".�.�.�� T1E _ .� .' .' CHAIR CHAIR CHAIR LESS THAN 54' y Je • ' • SLAB STRANDS SLAB STRANDS SLAB STRANDS CHAIR LAYOUT •'"''1, WHERE APPLICABLE •i:; ii;' WHERE APPLICABLE WHERE APPLICABLE #4 BARS @ 12' BEAM STRAND 2• #5 BARS ' i O.C.E.W. #4 BAR WHERE BEAM STRAND SLAB STRANDS APPLICABLE WHERE •I' DRAPE BEAM APPLICABLE : • � I STRAND _ SHEATHING CUT BACK BEHIND ANCHOR H #3 SUPPORT STAKE WHEN INDICATED _ t' (CARE SHOULD BETAKEN TO H #3 SUPPORT STAKE N H V� ON PLAN, TYPICAL ENSURE SHEATHING DOES NOT O y/ A'-• CHAIR 3• PROTRUDE INTO THE ANCHOR) OAmV4 o DETAIL "B" DETAIL "B1" STANDARD BRICKLEDGE WHENP BRICKLEDGE WHEN D ETAI L "G" DROP DETAIL FORM EXCAVATION 6. APPLICABLE ,pp5 APPLICABLE�pSE 0L ' f. GpPnO'Y BRICKLEDGEV 6. BRICKLEDGE TENDON INSTALLATION APPLICABLE WHEN APPLICABLE r z 1•#40AOKuPBAR AT STRESSING -END #4 BARS @ 12' O.C.E.W. SLAB STRAND p 7 •.° e• ^�' .•..a i; #4 BACK UP BAR 1- CHAIR CHAIR i� CHAIR r a}• POCKET TOP OF A '�' _ FORMER GRADE .. SLAB STRANDS TOP OF SLAB STRANDS": 16 p ' (12 IN.) �- WHERE APPLICABLE GRADE. -•. : WHERE APPLICABLE SLAB STRANDS = WHERE APPLICABLE CHAIR i ' DRAPE BEAM STRAND , ; 2- 45 BARS tc � • WHEN INDICATED • ' #4 BARS @ 1? ON PLAN. TYPICAL DRAPE BEAM O.GE.W, I 9 � SLABSTRAND CUT PLASTIC STRAND TOP OF It`:. DRAPE BEAM -'•': BEAMHERE O WHEN INDICATED GRADE WOOD p p y( _ STRAND 3'-0' MAX W EXCAVATION ON PLAN, TYPICAL �;'� ,.1.. r ° WHEN INDICATED L BEAM STRAND FORM ON PLAN, TYPICAL AS SPECIFIED 1- #4 FOR L = 14' OR LESS DETAIL "C" DETAIL "C1" o ar NOTE: DETAIL"F' 3-#4FORL-2cT0COMPLETED 3V CAN BE STRESSING END INSTALLATION BRICKLEDGE WHEN D ETAI L If FORDETAIL"DF1 °. D ETAI L If 1 " APPLICABLE 'S' STRAND AS BRICKLEDGE uLEKCLEOGDIGE WHEN SHOWN ON PLAN 1}' MIN. N FIXED -END SHEATHING PLASTIC 1• #4 BACK UP BAR ANCHOR STRAND SHEATHING CHAIR 3# CUSHION CHAIR p m L SAND, TYP. CHAIR SLAB STRANDS STRIP TOP OF POST•TENSION STRANDS ;o SHEATHING GRADE WHEN INDICATED s WHERE APPLICABLE SLAB STRANDS ON PLAN, TYPICAL WHERE APPLICABLE 20d NAIL STIRRUPS #4 BARS @ 1Y 'BS° STRAND AS (MIN.) STIRRUPS O.C.E.W. 2 x D TYPICAL SHOWN ON PLAN WHEN SPECIFIED WHEN SPECIFIED STRANDS FIXED -END (DEAD-END) N DRAPE BEAM #3 STAKES AS REQUIRED V SPECIFIED BN THE BEAM.ARE LWOOD INSTALLATION O :A STRAND TO MAINTAIN A 3'FORM o 3- #4 BARS WHEN INDICATED CLEARANCE FROM THE TIE'BS' STRANDS TOGETHER TOP VIEW :" 3- #4 BARS TOP & BOTTOM. Ni . J! ON PLAN, TYPICAL AND INSTALL SIDE BY SIDE TOP & BOTTOM. p BOTTOM OF THE BEAM AS A SINGLE'BS' STRAND. 54' MAX. SPACING L� INSTALL ANCHORS SIDE BY SEE •2 DETAIL STANDARD DETAILS DETAIL "D" DETAIL "H" DETAIL "M'.' BEAM STRAND "BS" DETAIL 90OLOLOdld NOTES: 1. TO PREVENT SETTLEMENT DUE TO SOIL CONSOLIDATION, OJi;••t S`3yhj Z - z 6" 13 SPACES @ 4'-2" ± 6" ALL EXTERIOR FOUNDATION BEAMS MUSTBE FOUND �'••• _ �_' •• �� o ¢ o MINIMUM OF 12 INCHES INTO UNDISTURBED SOIL W " • �••' °� �► : O : cn S J ac o FOUNDATION SITE CONTAIINS FILL (MAX. 3'-0'), THE DEE G � �c : Q u� < in BEAM DETAIL SHOULD BE USED IN THESE FILLED AREAS. • a ui m Lo F q DIAGONAL: 7/8" BFOR SITES WHERE FILL IS GREATER THAN 3'-0", PLEASE A , Lf) CONTACT AGTM ENGINEERING LLC TO INCORPORATE PIERS 6 _ �• i tt �' N U) `CV � U INTO THE DESIGN. �✓1 **� a 0• 2 __� U m � r t- N N 3. 4'oOF CUSHION SAND UNDER CONCRETE SLAB IS ���� ° �o6 S57 I I cn m cn (n cn m Cn rA N cn Cn m a _ J L _ _ RECOMMENDED. BS58 r - - - - - r - - - - r - - - - - - - r - - - r - - - - - 4. PROVIDE A 6 MIL POLYETHYLENE MOISTURE RETARDER z I I I I I BENEATH SLAB AREA. N I I f I I I I I I 5. ALL STRANDS 1/2" DIA. - 270 K. 6. THIS FOUNDATION DESIGN IS CONSIDERED INVALID (n S 57 I I U I I o I I I I I I p I I N I I I I UNLESS ACCOMPANIED BY A LETTER FROM AGTM Q W CD I I I I I I I I I ENGINEERING LLC AUTHORIZING ITS USE ON A SPECIFICF- I I I I I I I I LOT & BLOCK, OR ADDRESS. O Q co ('3 Z S57 I I - - - - I I 7. PLANS CAN BE REVERSED ON LOT AT BUILDERS Z = r ^ ��1 W _ L _ J L_______-__J L-___� L_-_ -_ J - O �fd •O 2-BS58 r--------- r--------- --- r---- -- r-------- DISCRETION. _ O m to QU I I I I I I I I 1. 8. PLANS ARE FOR STRAND AND BEAM PLACEMENT ONLY. O X r Q U cn S57 I I I I I E I I SET FORMS, DROPS, HANDICAP RAMPS, ETC., BY LL f- F- O N U Y O I I I I I I I I I ARCHITECTUAL FLOOR PLAN OR AS SPECIFIED BY 00 Z 0 m CQ I I I I I I I I A OWNER/GENERAL CONTRACTOR. Z Z O� Q cn w C I I I I I I rn 1 1 I 9. AT CONTRACTORS OPTION, LIVE END AND DEAD END Lu F- Z Z m S57 f l I I I I I I C3 C REVERSAL IS PERMITTED. (� I r Z Z I I I I I 1 I I I uj 10. AT CONTRACTORS OPTION, BRICK LEDGE MAY BE U) V O Z u- Q J co O +I BS58 L _________J L__________J L_---_--__— L__-- ___J �________-J.i INCLUDED OR OMITTED AT EXTERIOR DOOR OPENINGS. z Q a�C14 b S57----------------- - - - - -- r---- ---� r---- a r c~n 11'-10" III 11'-5" III 11'-5" III 10'-0" I I 1 10'-411 I 11. DRAINAGE, DRAINAGE, DRAINAGE. THE FINAL GRADE Z O C3 co I AROUND THE FOUNDATION SHALL BE 8" BELOW THE TOP OF I - I I THE FOUNDATION AND SLOPE AWAY FROM THE V J w S57 I I I I I I N I I FOUNDATION A MINIMUM OF 3" IN 5'-0". O O U A II B it I I I d a 12. VIBRATE CONCRETE @ ALL CABLE LOCATIONS Q_ O U co S57 I I I I I ESPECIALLY AT CORNERS WHERE SEVERAL CABLES ARE cv----JL----------JL-------- I----- ---J L_ _ BS58 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ - _ _ _ ANCHORED. MAXIMUM CONCRETE DENSITY IS REQUIRED I I I I I I I DROP 1 TO INSURE THAT A "BLOW-OUT," DOES NOT OCCUR DURING (-il I I I I I I I I I CABLE STRESSING, = T U. 0 S57 I I I I I I I 13. THE FOLLOWING SYMBOL INDICATES DROP IN p I I I I I I rn I I I C FOUNDATION. THE AMOUNT OF DROP AND EXACT c I 1 1 I I I I I I LOCATION IS TO BE DETERMINED BY PLAN OR AS S57 I I I I I I I DIRECTED BY OWNER/CONTRACTOR.. 0 LL I I I I I DROP b, I I I I 2-BS58 L - ---- L_- ------ ------ -- -- _-__J L--------J a r-----------j r—--------� r------- -- r---- ----� ----------- S57 I I I I I I I w 6i o i FOUNDATION: o S57 1. THICKNESS T= 4" I II II W I II I m I I I I I a ' 2. BEAM WIDTH W= 10"oy 3. BEAM DEPTH D=28„ S57 __ _ U) +I S58 r--I r 4. A275 1 w SQ, FT. md II YSN Z F- U 5. EST. CONCRETE 91 YRDS. �QoS37 - � Q0 U)c%I S20 J L _ J O ° BS21 a J LLI U F STEEL REQUIRED. SEE DETAILS >^ a C-co Q r z � E °° °D m 55'-U'CAUTC C ^n PASSESITHROUGH A PON: IN THE AL MBING OPTHAT A LE ENING, r ION: VIBRATE ALL CABLE LIVE G WMOVE CABLE TO EDGE OF OPENING. AD ENDS TO ENSURE MAX. LL CABLE SPACING CAN BE ADJLSTED, BUi INY CONCRETE ESPECIALLYNO EVENT CAN CABLESPACING BE WHERE MULTIPLE STRANDSGREATER THAN V-0" O.C. OGETHER Q LU BUILDING PERMIT CITY OF COLLEGE STATION;. 11&I TVXAS' 4VENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ----------------.------------------------------------------------------------ Application Number 07-00002189 Date 8/07/07 Application pin number 382503 Property Address . . . . . . 2461 NEWARK CIR Property ID: 184200-2501-0190 R #: R303657 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE PH 5 SEC 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL DISTRICT Application valuation . . . . 142296 Owner Contractor ------------------------ ------------------------ GREENS PRAIRIE INVESTORS LTD CLASSIC CENTURY HOMES 4490 CASTLEGATE DR 5001 HWY 287 S COLLEGE STATION TX 778453388 ARLINTON TEXAS ARLINGTON TX 76017 (817) 561-4369 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2156.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 441.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit pin number . 517383 Permit Fee . . . . 589.00 Plan Check Fee .00 Issue Date . . . . 8/07/07 Valuation . . . . 142296 Expiration Date . . 2/03/08 Qty Unit Charge Per Extension BASE FEE 460.00 43.00 3.0000 THOU BLDG, VAL 100001-500000 129.00 ---------------------------------------------------------------------------- Special Notes and Comments -Engineered Slab and Framing BUILDING DEPT REPRES T IVE: APPLICANT: �� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number 07-00002189 Application pin number . . . 382503 Page 2 Date 8/07/07 Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 301-) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. BORACARE TREATMENT IS A SUITABLE SUBSTITUTE. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES. PROOF OF METHOD TO BE USED SHALL BE RECEIVED IN OUR OFFICE BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2006 INTERNATIONAL RESIDENTIAL CODE Surface Drainage Shall Be Diverted to an Approved Point of Collection. Lots Shall Have a Grade Fall Minimum of 6" inches Within the First 10' feet Away From the Foundation Walls. ELECTRICAL SHALL BE INSTALLED PER 2005 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND Hearth Extension Needed For Fireplace Opening <6 sq. ft.(8" side & 16" front) For Openings >6 sq. ft. (12" side & 20" front) ALL FRAMING SHALL COMPLY WITH 2O06 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM I41_YUTOMOBILES ------------------------------------------ --------------- . BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 07-00002189 Date 8/07/07 Application pin number . . . 382503 ---------------------------------------------------------------------------- Special Notes and Comments PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION ACCESS TO JACUZZI TUB*CIRCULATION PUMPS SHALL BE PROVIDED IN ACCORDANCE WITH 421.5 OF THE 2006 INTERNATIONAL PLUMBING CODE. IF NOT DETERMINED BY MANUFACTURER IT SHALL BE A MINIMUM OF 12" X 12" AND IF PUMP IS GREATER THAN 2' FROM ACCESS OPENING THEN IT MUST BE 18" X 18" OPENING .IF LAWN SPRINKLERS IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT A Minimum of No. 15 Asphalt Felt or Other Approved Water Resisitive Barrier Shall be Placed Over All Exterior Sheathing Per 2006 IRC Section R703.2 THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE PROPERTY LINE IS 25' AND MINIMUM WIDTH OF 12' ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2006 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. Also assure proper protection of pipe to U.V. light. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WOR S ON SE LATE OFF BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov Application Number . . . . . 07-00002189 Application pin number . . . 382503 Page 4 Date 8/07/07 Special Notes and Comments THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. FORM SURVEY MAY BE SUBMITTED IN PLACE OF STRINGS. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS DEPENDING ON PERCENTAGE OF WALL TO GLAZING RATIO UP TO 20% A .40 OR LOWER FACTOR AND ABOVE 20% TO 30% A .35 FACTO OR LOWER SHALL BE MET. SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O06 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES. THIS INCLUDES BOTH WATER HEATERS AND CLOTHES DRYERS. Other Fees SEWER TAP 4" WATER TAP 3/4" 350.00 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ---------------------------------- - --- -- - ---•----- BUILDING DEPT REPRESENTATIVE: r APPLICANT: BUILDING PERMIT ' CITY OF COLLEGE STATION 1161 TEXAS AVENUE, COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 http://bpinspect.cstx.gov ---------------------------------------------------------------------------- Page 5 Application Number . . . . . 07-00002189 Date 8/07/07 Application pin number . . . 382503 Permit Fee Total 589.00 589.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1339.00 1339.00 .00 .00 ------------------------------------------ JtAetz ---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101'TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 07-00002190 Date 8/07/07 Application pin number . . . 473130 Property Address . . . . . . 2461 NEWARK CIR Property ID: 184200-2501-0190 R #: R303657 Application type description TEMP POLE Subdivision Name . . . . . . CASTLEGATE PH 5 SEC 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL DISTRICT Application valuation . . . . 0 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS LTD ------------------------ CLASSIC CENTURY HOMES 4490 CASTLEGATE DR 5001 HWY 287 S COLLEGE STATION TX 778453388 ARLINTON TEXAS ARLINGTON TX 76017 (817) 561-4369 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit pin number . 517391 Permit Fee . . . . 20.00 Issue Date . . . . 8/07/07 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: Jun 20 07 02:04p Cch - B/cs 979 690 3823 p.2 C7ry oPR>tGE,S�A'1#� APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77040 (979) 764-3970 (979) 704-3496 FAX WWW.cm.GoV FPOLE usa Qt+yCREG ADDRESS/LOCATiON: K �'� / LOT _ j� BLOC;( SUBDIVISION J C 5 TLETL ✓ SE BUSINESS/OWNER NAME: LA55 IC T C PHONE:��"; CONTRACTOR/HOMEOWNER: 5(C oro R t-i PHONE: !- (oq CONTACT PERSON FOR /REVIEW COMMENTS: rR�� pcSRRlS PHONE": 4�� FAX:Ql V(pQD'3Q`�j EMAIL: ELECTRICIAN: PLUMBER: HVAC: GOOD CENTS (Residential only): ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION • SLAM ONLY DUPLEX (Landscape Plans) REMODEURENOVATION' SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: _ '5ZAA C- 25;l ll-y PROPOSED USE: _ 6ea.4 t'-9n�f-) jj7�vG-r1jj j HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL ycs TEXASACCESSI IUTYSTAN ARD'I ROJECTR1rC315TI3ATION#EA6PRJ N/A VALUATION: $ I TOTAL AREA: _22J HEATED AREA 21 (Cost of Lbbm a Materials) PUBLIC SEWER OC� Q SEPTIC/T'REATMEW SYSTEM EWE RTAP: t� WATER TAP: Sap - 3 i / a OTHER TAP: SUE \,yam TEMP Pole S2P NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: GARAGE TYPE: SINGLE Q DOUBLE a TRIPLE ATTACHED DFQACHED CARPORT U ob S FLEE i 426cIC bR kc K �D-Sl (6&:s 0-bmeo5rn bt� SIGNATURE OF APPLICANT: 'if proposed work involves new commBmiao&S040kjoFacade im emenEs/renovalions to an existing commerclat property, building elevatlons arb required. eeoee.Bee♦eeeeeeeeesesoeeeoeoeeeoeesooeooee♦eeeeee+eeeeeeeee OiircIal Use Only _ZrIp Plans Examiner Z&44,A,, W 0)/ It X4, eotu' Acce S5 al i h'et [7 " Zoning Official manta: E or NO Fire Marshall Jun 20 07 02:05p Cch - B/cs 979 690 3$23 p.3 t ir f If Energy? Code Compliance Information Yo Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling I (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC (Solar Heat Gain Coefficient) Glazing U-Factor It value of ductwork A/C SEER Rating Protection Against Subterranean Termites SAS L aw R- 22 ibA7 7 (3 Chemical Terrniticide Treatment (Soil Treatment) ❑ Chemical Termiticide Treatment (Field Applied Wood Treatment) ❑ Physical )Barriers ❑ Other *Verification of Application shall be submitted to the City of College Station Building Department prior to issuance of the Certificate of Occupancy. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# 0 q DATE: I BUILDING ADDRESS: I. Foundation Requirements- Minimum City Foundation Standards NA/ A. Concrete minimum compression strength of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 6mil. Poly min. D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Footings 30" exterior, 24" interior, unless over 60' long must be 30" 3. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated K II. Framing: Floor, Wall, Ceiling and Roof Requirements INAkin A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex OK 1. One -hour rated extending to roof deck K E. Header sizes indicated on plans N F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Sheathing indicated on plans for Wall Bracing 2. Moisture barrier indicated on plans 3. Exterior Wall Covering J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans M. Span exceeding code tables must be engineered N. Rafter size, spacing, roof slope & purlin bracing if required to reduces an O. Roof covering P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations 71 I PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX R. 18" Overhangs allowed on zero lot line, non-combustible perforated soffit only S. All walls within 3' of property line to have protected openings. III. Stairway Requirements OK OK A. Stairway Details OK 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than thirty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening ? 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must meet IRC Chapter 10 Requirements V. Electrical Service Requirements A. Electrical plan to include: NAr 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi N B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NAOW A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements N A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NNW Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking Street Ordinance Requirements N Maximum drive width for residence is 25' combined for circular and 12' minimum for single Minimum 20 feet from driveway to side(intersecting) street property line sight triangle Driveway access to lesser street for corner lots Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N Does not block an water course or divert an flow Elevation certificate needed OK